Hytronik Electronics HC418VRF Lighting Control Switch User Manual of HC418V RF HC424RF
Hytronik Electronics Co., Ltd Lighting Control Switch of HC418V RF HC424RF
User Manual
HYTRONIK ELECTRONICS CO.,LTD Block A6, Nan’pu Science & Technology Park, Hao’si, Shajing Street, Bao’an District, Shenzhen, P.R.C. 518104 T: 86 755 27322200 F: 86 755 27308687 E: info@hytronik.com W: www.hytronik.com HC418V/RF HC424RF 120~277VAC 60Hz 120~277VAC 60Hz 200W@120VAC; 500W@277 VAC(capatitive Load) Up to 30 meters indoor transmission and 100 meters in open area. Fixed address coding with 10 channels (max. 10 groups) Diameter Max. 12m 5s~30min WORKING TEMPERATURE PROTECTION LEVEL STANDBY PERIOD STANDBY DIMMING LEVEL Max. 6m Max. 6m -20 ~ +60℃ -20 ~ +60℃ 0s, 10s~1h, + 10~50% 0s, 10s~1h, + 10~50% RF Antenna LED indication Daylight sensor Detection area Hold-time Daylight threshold Stand-by period Stand-by dimming level RF antenna Rotary coding switch Stand-by period Stand-by dimming level Rotary coding switch Model NO.:HC418V/RF 1.4 Model NO.:HC424RF 120~277VAC 60Hz. 2.1 Ensure that the electricity supply is switched off completely before installing or servicing this product. 2.2 Keep the RF antenna at least 3cm away from the driver or ballast. Wring with any 1~10V control gear to achieve dimming function. LED Driver HC418V/RF LED Driver HC424RF RF wireless communication makes installation easier with no cables connection.The motion at 1 sensor (the master unit) can be passed onto other pre-defined individuals (the slave units) through RF transmission. This wireless radio wave transmission can reach 100 meters in open area with internal RF antenna, 30 meters blocked by one wall, 20 meters blocked by two walls. Settings for HC418V/RF Detection Area: This determines the effective range of the motion detector and is set by DIP switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range.The following settings are available: I – maximum range up to 100% II – 75% III – 50% IV – 10% Hold time: 100% II 75% III 50% IV 10% This determines the time the fitting remains at 100% level on motion detection and is set sith DIP swiches at the sensor itself, refer to figure. The walk test seing is useful when installing the fitting to establish correct operation and range. The following settings are available: I – 5S II – 30S III – 1 minute IV – 5 minutes V – 10 minutes VI – 20 minutes VII – 30 minutes II III IV VI VII 2 3 5S 30S 1min 5min 10min 20min 30min Daylight sensor: This setting holds off the 100% light output should there sufficient daylight and is set using DIP switches at the sensor, refer to figure. The following settings are available: I – Disable II – 50 lux III – 10 lux IV – 2 lux Disable II 50 lux III 10 lux IV 2 lux *In disable mode the lamp(s) will always be on with motion detected and operate at 100% light output, even in bright daylight. Stand-by period (corridor function) This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. I – 0S II – 10S III – 1 minute IV – 5 minutes V – 10 minutes VI – 30 minutes VII – 1 hour VIII – +∞ Note: “0s” means on/off control; “+∞” means 2 steps of dimming control, fixture never switch off. II III IV VI VII VIII 2 3 0S 10S 1min 5min 10min 30min 1h +∞ Stand-by dimming level This is the dimmed low light output level you would like to have after the hold-time in the absence of people. I – 10% II – 20% III – 30% IV – 50% 10% II 20% III 30% IV 50% Settings for HC424RF Stand-by period (corridor function) This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. I – 0S II – 10S III – 1 minute IV – 5 minutes V – 10 minutes VI– 30 minutes VII– 1 hour VIII– +∞ Note: “0s” means on/off control; “+∞” means 2 steps of dimming control, fixture never switch off. II III IV VI VII VIII 2 3 0S 10S 1min 5min 10min 30min 1h +∞ Stand-by dimming level This is the dimmed low light output level you would like to have after the hold-time in the absence of people. I – 10% II – 20% III – 30% IV – 50% 10% II 20% III 30% IV 50% SECTION 4 RF GROUPING RF grouping (max. 10 channels) Using a screwdriver to adjust the rotary switch on both the master & slave unit, to keep them pointing at the same channel, the grouping is then automatically completed. 10 channels (max. 10 groups) available for both the master & slave unit. slave master Using a screwdriver to point the arrow to the same position on the master unit and slave units. SECTION 5 FUNCTIONS 5.1 100H burn-in mode for fluorescent lamp With simple operation, rapidly turn off/on the fixture 3 cycles wihin 3 sec. (the green LED on the sensor flashes and the fixture blinks 3 times to indicate the success of setup), lamp will be 100% on for 100 hours, and then automatically goes to sensor mode after 100 hours. This is crucial to secure the lifetime of fluorescent lamp, when new fixture is installed,or old lamp is replaced. This 100h burn-in feature can be cancelled by turn off/on the fixture 1 cycle within 1 sec. 5.2 Ambient daylight threshold With simple operation, rapidly turn off/on the fixture 2 cycles within 2 sec: a. the green LED on the sensor flashes slowly for 5 seconds, meanwhile the fixture blinks twice. b. the daylight sensor measures and remembers the surrounding lux for 1 sec. c. the fixture and green LED is on for 10s to indicate the success of learning. * This feature enables the fixture to function well in any real application circumstance, where the daylight penetrated into fixture may vary a lot. * The latest surrounding lux value overwrites previous lux value learned. * Both the setting on DIP switch and the learned ambient lux threshold can overwrite each other.The latest action stays in validity. 5.3 Zero-cross relay operation Designed in the software, the sensor switches on/off the load right on the zero-cross point, to ensure the min. current passing through the relay contact point, and enable the max. load and life-time of the relay. 5.4 Loop-in and loop-out Double L N terminal makes it easy for wire loop-in and loop-out, saves the cost of terminal block and assembly time. * Motion sensor overwrites daylight sensor, meanning the daylight sensor starts to check the ambient natural light only when the lamp is switch off (motion hold-time ellapsed). * 1-10v output on the master unit HC418V / RF is isolated, SELV output; while the 1-10v on the slave unit HC424RF is non-isolated. SECTION 6 TROUBLE SHOOTING MALFUNCTION CAUSE REMEDY The load will not work The load is always on The load is on without any identifiable movement The load will not work despite movement CAUSE REMEDY Incorrect light-control setting selected Adjust setting Load fault y Replace l oad Mains switch OFF Switch ON Continuous movement in the detection zone Check z one setting The sensor is not mounted for reliably detecting movement Securely mount enclosure Movement occurred, but not identified by the sensor (movement behind wall, movement of small object in immediate lamp vicinity etc.) Check zone setting Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small Check zone setting FCC NOTE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS OR CHANGE TO THIS EQUIPMENT. SUCH MODIFICATIONS OR CHANGE COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Modify Date : 2015:05:26 13:57:05+08:00 Create Date : 2015:01:16 09:25:14+08:00 Metadata Date : 2015:05:26 13:57:05+08:00 Creator Tool : Adobe Illustrator CS5 Thumbnail Width : 184 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 9011 bytes, use -b option to extract) Format : application/pdf Title : User manual of HC418V-RF+HC424RF Document ID : uuid:719a4bd2-aa17-4051-9d8a-416c368182aa Instance ID : uuid:8ed74e8b-8e49-43b7-ad35-84e0f6a166f7 Rendition Class : proof:pdf Producer : Adobe PDF library 9.90 N Pages : 1 Has Visible Transparency : False Has Visible Overprint : False Max Page Size W : 210.001652 Max Page Size H : 297.000132 Max Page Size Unit : Millimeters Font Name : ArialMT, Arial-BoldMT Font Family : Arial, Arial MT Font Face : Regular, Bold Font Type : Open Type, Open Type Font Version : Version 3.00, 001.001 Font Composite : False, False Font File Name : ARIAL.TTF, arial-bold.otf Plate Names : Black Swatch Groups Group Name : 默认色板组 Swatch Groups Group Type : 0 Page Count : 4 Creator : Adobe Illustrator(R) 15.0 For : , Bounding Box : 0 0 596 842 Container Version : 11 Creator Version : 15 Image Height : 842 Image Width : 596 Image Size : 596x842 Megapixels : 0.502EXIF Metadata provided by EXIF.tools