ICP C8DNL075B12A1 User Manual 80+ SINGLE STAGE GAS FURNACE Manuals And Guides L0502516
ICP Furnace/Heater, Gas Manual L0502516 ICP Furnace/Heater, Gas Owner's Manual, ICP Furnace/Heater, Gas installation guides
User Manual: ICP C8DNL075B12A1 C8DNL075B12A1 ICP 80+ SINGLE STAGE GAS FURNACE - Manuals and Guides View the owners manual for your ICP 80+ SINGLE STAGE GAS FURNACE #C8DNL075B12A1. Home:Heating & Cooling Parts:Icp Parts:Icp 80+ SINGLE STAGE GAS FURNACE Manual
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
INSTALLATION Blower Door INSTRUCTIONS Replacement This kit is designed to replace the blower door on the N8MPN, N8MPL, N9MP1, N9MP2, *8MPN, *8MPL, *8DNL, *9MPD, *8MPT, *9MPT, *8MPV, *9MPV, H8UHh, MUF, HL, and FUH series furnace. * Denotes Brand (T, H or C) Read Examine kit to determine the replacement blower the entire that the following door: Parts parts are present Part# Model: Tempstar Door Screw * Wiring Label Single Stage 2-Stage Variable Speed (050) Variable Speed Export 50 Hz Warning Label Operating Instruction Instructions Diagnostic Label Single Stage 2-Stage Seal Strip Faceplate or 1013490 completely 1014488 2 1014484 1014485 1014486 1014487 1014495 1013810 1013494 1013144 441 06 1047 00 1 1 1 1 1 1 1 3 1 1014488 2 1014484 1014485 1014486 1014487 1014495 1013810 1013494 441 06 1047 00 1 1 1 1 1 1 1 1 1012899 1013348 1013144 1 1 3 one Wiring FUH asshown 25-24-63-4 Model: *SMPN, *SMPL, *8DNL, H8UHh, MUF, H (SeeFigure2) * Denotes Brand Figure 2 *8MPT, *SMPV, *8MPN, *SMPL, *SDNL, *SMPT, *SMPV, H8UHh, MUF, HL Install Faceplate& Trim Strips (Tempstaronly) r_ _ /Install Seal Strips (3) \\\ \_"_,_ "': _ as shown 2 2 contact your parts supplier. Fast Parts. Blower Door Kits. InstalIWarning Label & \ _ Operating Instructions _]- " asshown 1. N8MPL, Place one Wiring FUH (SeeFigure 1) Place door. 2. Place seal strips (2) along the side edge on the inside of the door. Trim seal strip to length. 3. Place door. 4. Place Operating Instruction part 1013494 ing label on the outside of the door. 5. Insert door screws (2) into screw bottom of the door. 6. Install Label N8MPL, g Label 1. Warning Label N8MPN, InstallWarning Label & OperatingInstructions as shown NOTE: N8MPN, installation. Figure 1 I N9MP1, Installation N9MP1, the 1 1013487 1010714 If any part is missing, immediately Note all parts will be used. Model: starting Qty or 1013491 Trim Strip Hole Plug 1/4"Diameter * Denotes parts available through Others are available only through with before List Description Model: Entry Level, C, H Door Screw * Wiring Label Single Stage 2-Stage Variable Speed (050) Variable Speed Export 50 Hz Warning Label Operating Instruction Seal Strip Instructions 1013489 instructions part 1014484 part 1013810 on the inside on the outside holes of the 1014484 1014485 1014486 1014487 on the inside for for for for of the door. *8MPN, *8MPL, *8MPT *8MPV050B12 *8MPV for H8UHh, *8DNL MUF, HL 2. Place seal strips (2) along the side edge on the inside door and trim to length. 3. Place another seal strip along the bottom of the door and trim to length. 4. Place door. 5. Place Operating Instruction part 1013494 ing label on the outside the door. of the at the front Label Part 1014495 below the warn- located Part Part Part Part Label as shown Warning Label part 1013810 of the edge on the inside on the outside below of the the warn- the door on the furnace. 441 06 1047 00 (7/03) 6. (Tempstar only) Insert Face Plate on the front of the door. 7. Install 8. (Tempstar only) Place edge of the door. Hole Plugs Trim Strips Insert door screws (2) into screw bottom of the door. 10. Install 3 _ \_ Place seal strips (2) along the side edge on the inside door and trim to length. 3. Place another seal strip along the top edge on the inside the door and trim to length. 4. Place door. 5. (Tempstar only) Insert Face Plate on the front of the door. 6. (Tempstar 7. (Tempstar only) Place edge of the door. 8. Insert door screws (2) into screw bottom of the door. 9. Install the door on the furnace. (2) along the front side holes located at the front *9MPD, *9MPT, *9MPV (See Figure3) Brand Figure 2, the door on the furnace. N9MP2, * Denotes holes (2) on faceplate. 9. Model: on the designated N9MP2, _ / *9MPD, *9MPT, *9MPV (3) asshown Warning Label only) Install CUTS AND ABRASION /// Failure to follow bodily injury. part 1013810 of on the outside of the on the designated holes Hole Plugs (2) on faceplate. Trim (2) along Strips of the holes the front side located at the front HAZARD. this caution could results in Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. NOTE: screws, If replacing blower drill new door screw eter before inserting screws from original cluded with this kit. 1. Place NOTE: one Wiring Label on the inside of the door. door with machine thread thumbholes from 1/8" diameter to 1/4" diam- thumbscrews. Use machine thread thumb(old) door. Discard black door screws in- If door screws from original door are not available, use 10-32 thread screws available at local hardware stores. :Part1014484forN9MP2,*9MPD Part 1014485 for *9MPT Part 1014486 for *9MPV050F12 Part 1014487 for *9MPV -2- UN F
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 16:23:07 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools