Installation Downflow Instructions Kit for EBP, EBX, EBW and EBV Series These instructions must be read and understood completely before attempting installation. The downfiow conversion following items: Fire Hazard The purpose of the subbase assembly is to maintain a 1" clearance to combustible materials. Attach Failure death. supply duct to inner flange to do so can result Coil bracket Coil baffle Screws Foam gasket of subbase. in fire, bodily injury or WARNING: Before beginning any installation or modification, be sure the main electrical disconnect switch is in the OFF position. Tag the disconnect switch with a suitable warning label. Electrical shock can cause personal injury or death. INTRODUCTION Fan coils are factory-shipped for upfiow or horizontal-left applications. This instruction covers the installation of downfiow conversion kit on models EBP, EBX, EBW and EBV fan coils. The kit provides a means of installing fan coils in a downfiow position. DESCRIPTION AND USAGE The downfiow conversion kits are available for use on slope and A-coil versions of previously mentioned fan coils. When installed, the kit will provide proper condensate water drainage, as well as a means of supporting the coil. See unit Installation Instructions for proper kit part numbers. 7/I for slope units requires the for A-coil the (1) (1) (2) (1) The downfiow conversion following items: units requires Coil bracket (2) Support strap (1) Drainage hole plugs (2) Angle (2) Screws (4) Air seal (1) NOTE: The fan coils are factory shipped for upfiow or horizontal-left applications. Installation of the Downfiow Conversion Kit should be complete before the fan coil unit is positioned to ensure side access required for installation of the coil brackets. NOTE: If unit has electric heat with a circuit breaker, refer to electric heater Installation Instructions for repositioning of breaker assembly. IDNR 'D_ 1p/4E_NiHOLHE SI DES ) /000/ /000 / _-- SUPPORT STRAP A-COIL _ ANGLE "-_ A,q8437 --_ Fig. 1--Downflow A-Coil Brackets and Support Strap Location A90210 Fig. 2mPosition of Angles on A-Coil 482 01 2222 00 INSTALLATIONA-COILUNITSONLY 1.Remove all panels and expose blower and &Install remaining coil baffle at coil end opposite the coil coil areas. headers. (See Fig. 6.) 2.Remove any shipping clips securing coil. 3.Remove complete coil/drain pan assembly. a.Slide the longer flange of baffle between tube sheet and 4.Remove assembly. end of condensate pan. Be sure notch in baffle is fully seated below notch in tube sheet. and discard horizontal drain pan from coil &Drill four 1/4-in. holes (2 on each side) in fan coil casing at dimples provided. (See Fig. 1.) 6.Secure coil brackets (provided in kit) to casing sides. (See Fig. 1.) 7.Install support strap (provided in kit) across front of unit as follows: NOTE: The TXV sensing bulb must be insulated on slope coils in horizontal right and downflow applications. Failure to insulate bulb will result in performance loss. 7.Insulate TXV sensing bulb with cork tape or other a.Position flange on each end of strap between coil bracket and casing insulation. (See Fig. 1.) permanent insulating material. b.Secure support strap ends to coil brackets. (See Fig. 1.) &Invert coil assembly and slide it into unit with drain pan to &Remove and discard 4 clips (on corners of coil) securing coil assembly to rails for upflow applications. left side of fan coil. Secure coil assembly with screws. (See 9.Remove and discard factory-shipped air seal and drain tube assembly. Install 1-piece sheet metal air seal assembly provided with kit. &Reinstall fitting panel, blower panel, and coil access panel. 1&Tilt coil assembly back and slide angles (provided in kit) over each inside wall of condensate pan. Pop- riveted flange of angles should extend toward coil. (See Fig. 2.) Fig. 3.) Align holes connections. in panels with tubing and condensate 11.With fan coil in downflow position, slide coil assembly into unit. (See Fig. 3.) 12.Reinstall all panels. Align holes in panels with tubing and condensate connections. Casing was designed to allow 180 degree rotation of coil access panel and fitting panel. 1&Install 2 plugs that have been provided onto doors to seal unit. INSTALLATION- SLOPE COIL UNITS ONLY 1.Remove all panels and expose blower and coil areas. 2. Remove screw securing coil assembly to right side flange. Remove complete coil/drain pan assembly. &Drill two 1/4-in. holes in right side of casing at dimples provided (unit in upflow position). 4.Place fan coil unit in downflow position. &Secure coil bracket to left side of casing with 2 screws provided. (See Fig. 4.) &Remove top coil bracket from coil (2 screws). b.Align holes in gasket with holes in top coil bracket. c.Remove only half of the backing from the gasket. &Apply exposed half of foam gasket to under side of top coil bracket. (See Fig. 5.) e.Remove remaining piece of backing from gasket and press gasket into place. f.Replace top bracket onto coil. The 2 screws must engage the lanced holes. SLOPE COIL A-COIL -_ Fig. 3---CompletedDownflowConversion -- --r t/" |/' _J TOP BRACKET A98438 A98439 SLOPE COIL --> Fig, 4_Downflow Slope Coil -_ Fig. 5--Top Coil Bracket Gasket For Slope Coil Only Bracket SLOPE € \_. COIL BAFFLE CONDENSATE s,,/ PAN COIL BRACKET -_ Fig. 6--Coil Baffle Location (At End Opposite Coil Header) A98440
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 3 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 16:22:51 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools