IDT Technology BP5000BT Bosch Bluetooth blood pressure monitor User Manual users manual

IDT Technology Limited Bosch Bluetooth blood pressure monitor users manual

users manual

DRAFTDRAFTen  Instructions for Use es  Instrucciones de usofr  Mode d’emploi de   GebrauchsanleitungBlood Pressure Monitor BP5000 BT
Contents1. Introduction ...................................................................................................... 12. List of parts....................................................................................................... 23. Overview of symbols and functional features ................................................... 34. Setting up your blood pressure monitor ........................................................... 54.1  Installing the batteries .............................................................................. 54.2  Connecting the arm cuff to your blood pressure monitor ........................ 64.3  Setting up the wireless connection .......................................................... 75. Measuring your blood pressure ........................................................................ 86. Error messages on your blood pressure monitor ............................................ 127. Symbols and Functional Features ................................................................... 148. Cleaning, maintenance, and disposal.............................................................. 179. Technical data ................................................................................................. 1810. Regulatory ..................................................................................................... 19F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc. en
1. IntroductionThe Blood Pressure Monitor BP5000 BT is a device that you will use to measure your blood pressure and report the results to your care provider. The blood pressure monitor BP5000 BT connects wirelessly to your Bosch telehealth appliance, such as the Health Buddy or the T400.Read the entire instruction manual before you use your blood pressure monitor. If you have questions about your blood pressure monitor that are not answered by this manual, contact your care provider. If you have suggestions or feedback on this manual, you can send an email to doc.feedback@us.bosch.com. Refer to document number F.03D.601.425 Rev. A in your email. A response will be provided only if you request one. Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/20121 | enThis device is intended for use on adults aged 18-years and older.
2. List of partsEnsure that your Bosch blood pressure monitor package includes the following items:Keep the plastic packaging, the batteries, and the thin plastic film protecting the screen of the blood pressure monitor away from babies and children — they are a choking hazard.Bosch BP5000 BT Blood Pressure Monitor1208072SYSmmHgECDIAmmHgPUL/min1208072Four AA BatteriesArm CuffF.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 2
3. Overview of symbols and functional featuresYour BP5000 BT blood pressure monitor has a number of symbols and features.1208072SYSmmHgECDIAmmHgPUL/minBattery VolumeMemoryAppears when your previous blood pressure  measurements  are displayed.BluetoothAppears when the blood pressure monitor is connected to your telehealth appliance.PulseBlinks when your pulse  is being  measured.Start/Stop button Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/20123 | en
Memory buttonVolume  button Press to see and hear your last blood pressure measurement.*Do not press the Bluetooth or Reset buttons unless you are asked to do so by  your care provider.For a complete explanation of the symbols and functional features of your blood pressure monitor, see Section 7.Bluetooth  On / Off*Language buttonBy default, your blood pressure  monitor is set to  English.Reset button*Bluetooth pairing mode*Battery ribbonUse to remove batteriesF.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 4
4. Setting up your blood pressure monitorBefore you use your blood pressure monitor, you need to install the batteries and  connect the arm cuff to the blood pressure monitor. Next, you need to set up the  wireless connection between your blood pressure monitor and your Bosch telehealth appliance.4.1  Installing the batteriesTo install the batteries:1. Open the battery compartment cover on  the bottom of the blood pressure monitor.2. Insert the batteries (over the battery ribbon) as indicated by the diagram inside the  battery compartment.3. If your language is not English, select  your language by pressing the language  button.Language button Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/20125 | en
4. Replace the battery compartment cover.4.2  Connecting the arm cuff to your blood pressure monitorTo connect the arm cuff to your blood  pressure monitor, plug the air hose into  the air socket on the side of the blood pressure monitor.When you replace the batteries, ensure that you replace the complete set of batteries and that you do not use rechargeable batteries, or the battery fluid might leak.F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 6not use in combination with magnetic resonance imaging (MRI) .equipment. If MRI is to be performed, remove cuff connected to the unit from the patient
4.3  Setting up the wireless connectionTo set up the wireless connection between your blood pressure monitor and your Bosch telehealth appliance:1. Place your blood pressure monitor near your telehealth appliance to ensure a strong wireless connection.2. If your care provider has provided you with a Bluetooth  USB adapter, plug the Bluetooth USB adapter into any  available USB port on the back of your telehealth  appliance. If the Bluetooth USB adapter does not fit easily into the port, turn it over and try again.If your care provider did not provide you with a Bluetooth USB adapter, your telehealth appliance does not require one.Your blood pressure monitor is now ready to connect wirelessly to your telehealth appliance. The connection will be made automatically during your next telehealth session when your telehealth appliance prompts you to take your blood pressure measurement. Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/20127 | en
5. Measuring your blood pressureYou can wait until your telehealth appliance prompts you to measure your blood  pressure, or you can measure your blood pressure at any other time as directed by your care provider. Regardless of when you measure your blood pressure, the basic procedure is the same.Before you beginTo ensure accurate blood pressure measurements, observe the following  suggestions:•  Try to measure your blood pressure at the same time each day.•  Wait at least 30 minutes after exercising or bathing before you measure your blood pressure.•  If you roll your sleeve up, ensure that it does not constrict your blood flow.•  Sit in a comfortable position with your arm resting on a table at chest level and relax for at least 5 minutes.F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 8
•  When the arm cuff inflates, it will become fairly tight around your arm. This is normal. Remain still until the measurement is complete.ProcedureTo measure your blood pressure:1. Insert your hand into the sleeve of the cuff as shown, and then pull it up your arm. Ensure that the cuff makes direct contact with your skin.  •  The blood pressure cuff will automatically deflate if the cuff pressure exceeds 300mmHG. If the cuff pressure becomes too uncomfortable and does not automatically deflate, detach the cuff from your arm and contact your care provider.•  If you have had a mastectomy or a dialysis graft, do not put the arm cuff around the affected side. Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/20129 | en
2. Fasten the blood pressure cuff around your upper arm about 1 inch above your elbow.3. If you have a session waiting for you to complete on your telehealth appliance, start the session and follow the instructions on your telehealth appliance as you normally do. When you are prompted to measure your blood pressure, press the START button on your blood pressure monitor. The arm cuff inflates. F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 10
When the measurement is complete, your blood pressure and pulse are displayed, and the arm cuff deflates automatically.If you do not have a session waiting for you to complete on your telehealth  appliance, and you want to measure your blood pressure now, press the START button on your blood pressure monitor. The arm cuff inflates. When the measurement is complete, your blood pressure and pulse are displayed, and the arm cuff deflates automatically.4. Remove the arm cuff from your arm. If for any reason you need to measure your blood pressure again, wait at least 10 minutes. Your measurement is now complete. If you took a measurement during a session, the bluetooth symbol on your blood pressure monitor blinks five times to indicate that your measurement was transferred to your telehealth appliance. Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/201211 | en it is fail, and store the measurement data to memory. At the same time display EC20 for 25seconds, and then turn off.Then the backlight is on, And, announce and display the measurement value. If the bluetooth transition success, it will enter Turn Off mode after 60seconds timeout or press On/Off key.  .
6. Error messages on your blood pressure monitorWhen you use your blood pressure monitor, it might display an error message to indicate that a problem occurred.The following table provides explanations of the error messages that you might see on your blood pressure monitor and what you can do to try to resolve the problem. If you cannot resolve a problem, contact your care provider.Message DescriptionEC02 The blood pressure monitor could not detect a stable pressure signal. Try againEC04 The cuff did not deflate properly. Try againF.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 12
Message DescriptionEC10The blood pressure monitor was not able to connect to your telehealth appliance. Place your blood pressure monitor closer to your telehealth appliance, and try againEC20The blood pressure monitor could not transmit your measurements to your telehealth appliance. Place your blood pressure monitor closer to your telehealth appliance, ensure that telehealth appliance is on, and then try again.EC87The cuff did not inflate properly. Check the cuff hose for leaks or loose connections, adjust the cuff position, and then try againEC91 The blood pressure monitor could not detect a stable pressure signal. Try againEC92 An error occurred with the internal hardware of the blood pressure monitor. Try again Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/201213 | en
Message DescriptionEC98 An error occurred with the internal software of the blood pressure monitor. Try again.7. Symbols and Functional FeaturesFront of the blood pressure monitorSymbol DescriptionF.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 14
Symbol Description Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/201215 | enPlease fill in the blank
Top of the blood pressure monitorSymbol DescriptionBattery compartment (bottom)Symbol DescriptionF.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 16
Symbol Description8. Cleaning, maintenance, and disposalTo clean the blood pressure monitor, use a soft cloth dampened with water. Do not use any chemical or scouring agents. Ensure that liquid cannot penetrate into the blood pressure monitor.If your blood pressure monitor requires maintenance, contact your care provider. Contact your care provider regarding the disposal of your blood pressure monitor. Ensure that old batteries are disposed of in an approved location, separately from domestic waste. Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/201217 | en
9. Technical dataMeasurement range: 20 – 250 mmHG Protection class: IP21 Operating temperature:   41°F (5°C) to 104°F (40°C)Storage temperature: -13°F (-25°C) to 158°F (70°C)Power: 4 AA (R6P) batteries, 6VCuff size: 8.6 in x 12.6 in (22 cm x 32 cm) Expected battery life: 3 months (with 2 measurement cycles per day)Expected life of blood pressure monitor and cuff: 3 yearsPressure accuracy:     3 mmHGF.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 18Relative humidity: 15%%-93%%;%%Atmospheric pressure: 80kPa-105kPa%%Relative humidity: 15%%-93%%;%%Atmospheric pressure: 80kPa-105kPa%%
10. RegulatoryIntended Use: The Bosch Branded Blood Pressure Monitoring (BPM) System is intended for use by adults, to measure systolic and diastolic pressures as well as pulse rate, by the oscillometric method, in a telehealth system and for personal home use. Part 15Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Do not attempt to open or modify the device.Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate  Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/201219 | en
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.   Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/201220 | en
IndustryCanadaStatementThisdevicecomplieswithIndustryCanadalicence‐exemptRSS‐210.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.ThisClassBdigitalapparatuscomplieswithCanadianICES‐003.FCCID:NMTBP5000BTIC:3277A‐BP5000BTCanadianRepreSentativeInformationCompamyName: TJS Technical Services Inc. Adress: 203-304 Main Street Suite 160 Airdrie Alberta T4B 3C3 Canada ContactName: Thomas J Smith P.Eng E‐mailAddress: tsmith@tjstechnical.com TelephoneNo.: (403)612-6664 FacsimileNo.: (403)612-6664 Thisdevicecomplieswiththefollowingstandards:IEC60601‐1:2005/AC:2010IEC60601‐1‐2:2007ISO81060‐2:2009IEC80601‐2‐30:2009
WEEE ComplianceConsult Instructions for Use Use the blood pressure monitor indoors only.Keep dry.Keep away from heat.Shipping temperaturerange.RoHS ComplianceBluetooth® Tested to Comply  With FCC Standards  Contains FCC ID: R47F2M03GX  BF symbol for “applied parts”Robert Bosch Healthcare Systems, Inc.2118 Beechgrove Pl. Utica NY, 13501 USAManufacturer:F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.en | 22I revise some cotent next page/
Use the blood pressuremonitor indoors only.EN 60950Complianceen | 22WEEE ComplianceRoHS ComplianceConsult Instructions forUseBluetooth®Keep away from heat.Shipping temperaturerange.“ ”Robert Bosch Healthcare Systems, Inc.2118 Beechgrove Pl.Utica NY, 13501USABF symbol for applied parts
DRAFTDRAFTBlood Pressure Monitor BP5000 BT