IDT Technology BP5000BT Bosch Bluetooth blood pressure monitor User Manual users manual

IDT Technology Limited Bosch Bluetooth blood pressure monitor users manual

users manual

Download: IDT Technology BP5000BT Bosch Bluetooth blood pressure monitor User Manual users manual
Mirror Download [FCC.gov]IDT Technology BP5000BT Bosch Bluetooth blood pressure monitor User Manual users manual
Document ID1876711
Application IDjav2vWV7CCzY0R33E/NtyQ==
Document Descriptionusers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize153.56kB (1919562 bits)
Date Submitted2013-01-10 00:00:00
Date Available2013-01-10 00:00:00
Creation Date2012-12-05 15:03:50
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2013-01-03 18:08:31
Document Titleusers manual
Document CreatorAdobe InDesign CS6 (Windows)

en
es
fr
de
Instructions for Use
Instrucciones de uso
Mode d’emploi
Gebrauchsanleitung
AF
Blood Pressure Monitor BP5000 BT
Contents
1. Introduction ...................................................................................................... 1
2. List of parts....................................................................................................... 2
3. Overview of symbols and functional features ................................................... 3
4. Setting up your blood pressure monitor ........................................................... 5
4.1 Installing the batteries.............................................................................. 5
4.2 Connecting the arm cuff to your blood pressure monitor ........................ 6
4.3 Setting up the wireless connection .......................................................... 7
5. Measuring your blood pressure ........................................................................ 8
6. Error messages on your blood pressure monitor ............................................ 12
7. Symbols and Functional Features ................................................................... 14
8. Cleaning, maintenance, and disposal.............................................................. 17
9. Technical data ................................................................................................. 18
10. Regulatory ..................................................................................................... 19
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en
1. Introduction
The Blood Pressure Monitor BP5000 BT is a device that you will use to measure
your blood pressure and report the results to your care provider. The blood
pressure monitor BP5000 BT connects wirelessly to your Bosch telehealth
appliance, such as the Health Buddy or the T400.
This device is intended for use on adults aged 18-years and older.
Read the entire instruction manual before you use your blood pressure monitor. If
you have questions about your blood pressure monitor that are not answered by
this manual, contact your care provider.
If you have suggestions or feedback on this manual, you can send an email to
doc.feedback@us.bosch.com. Refer to document number F.03D.601.425 Rev. A in
your email. A response will be provided only if you request one.
1 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
2. List of parts
Ensure that your Bosch blood pressure monitor package includes the following
items:
Arm Cuff
Bosch BP5000 BT Blood Pressure Monitor
Four AA Batteries
Keep the plastic packaging, the batteries, and the thin plastic film protecting
the120
screen of the blood120
pressure monitor away from babies and children —
80
they80are a choking hazard.
SYS
mmHg
EC
72
72
DIA
mmHg
PUL
/min
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 2
3. Overview of symbols and functional features
Your BP5000 BT blood pressure monitor has a number of symbols and features.
Memory
Appears when
your previous
blood pressure
measurements
are displayed.
Bluetooth
Appears when
the blood
pressure monitor
is connected to
your telehealth
appliance.
Battery
3 | en
Pulse
Volume
Start/Stop
button
Blinks when
your pulse
is being
measured.
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
Volume
button
Bluetooth
On / Off*
Memory button
Press to see and
hear your last
blood pressure
measurement.
Bluetooth
pairing
mode*
Reset button*
Language
button
By default,
your blood
pressure
monitor is
set to
English.
Battery ribbon
Use to remove
batteries
*Do not press the Bluetooth or Reset buttons unless you are asked to do so by
your care provider.
For a complete explanation of the symbols and functional features of your blood
pressure monitor, see Section 7.
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 4
4. Setting up your blood pressure monitor
Before you use your blood pressure monitor, you need to install the batteries and
connect the arm cuff to the blood pressure monitor. Next, you need to set up the
wireless connection between your blood pressure monitor and your Bosch
telehealth appliance.
Language button
4.1 Installing the batteries
To install the batteries:
1. Open the battery compartment cover on
the bottom of the blood pressure monitor.
2. Insert the batteries (over the battery ribbon)
as indicated by the diagram inside the
battery compartment.
3. If your language is not English, select
your language by pressing the language
button.
5 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
4. Replace the battery compartment cover.
When you replace the batteries, ensure that you replace the complete set of
batteries and that you do not use rechargeable batteries, or the battery fluid
might leak.
4.2
Connecting the arm cuff to your blood pressure monitor
To connect the arm cuff to your blood
pressure monitor, plug the air hose into
the air socket on the side of the blood
pressure monitor.
not use in combination with magnetic resonance imaging (MRI) .
equipment. If MRI is to be performed, remove cuff connected to the unit from the patient
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 6
4.3
Setting up the wireless connection
To set up the wireless connection between your blood pressure monitor and your
Bosch telehealth appliance:
1. Place your blood pressure monitor near your telehealth appliance to ensure a
strong wireless connection.
2. If your care provider has provided you with a Bluetooth
USB adapter, plug the Bluetooth USB adapter into any
available USB port on the back of your telehealth
appliance. If the Bluetooth USB adapter does not fit easily
into the port, turn it over and try again.
If your care provider did not provide you with a Bluetooth
USB adapter, your telehealth appliance does not require
one.
Your blood pressure monitor is now ready to connect wirelessly to your telehealth
appliance. The connection will be made automatically during your next telehealth
session when your telehealth appliance prompts you to take your blood pressure
measurement.
7 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
5. Measuring your blood pressure
You can wait until your telehealth appliance prompts you to measure your blood
pressure, or you can measure your blood pressure at any other time as directed
by your care provider. Regardless of when you measure your blood pressure, the
basic procedure is the same.
Before you begin
To ensure accurate blood pressure measurements, observe the following
suggestions:
• Try to measure your blood pressure at the same time each day.
• Wait at least 30 minutes after exercising or bathing before you measure your
blood pressure.
• If you roll your sleeve up, ensure that it does not constrict your blood flow.
• Sit in a comfortable position with your arm resting on a table at chest level
and relax for at least 5 minutes.
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 8
• When the arm cuff inflates, it will become fairly tight around your arm. This
is normal. Remain still until the measurement is complete.
Procedure
• The blood pressure cuff will automatically deflate if the cuff pressure
exceeds 300mmHG. If the cuff pressure becomes too uncomfortable and
does not automatically deflate, detach the cuff from your arm and contact
your care provider.
• If you have had a mastectomy or a dialysis graft, do not put the arm cuff
around the affected side.
To measure your blood pressure:
1. Insert your hand into the sleeve of the cuff as shown,
and then pull it up your arm. Ensure that the cuff
makes direct contact with your skin.
9 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
2. Fasten the blood pressure cuff around your upper arm about 1 inch above
your elbow.
3. If you have a session waiting for you to complete on your telehealth appliance,
start the session and follow the instructions on your telehealth appliance as
you normally do. When you are prompted to measure your blood pressure,
press the START button on your blood pressure monitor. The arm cuff inflates.
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 10
When the measurement is complete, your blood pressure and pulse are
displayed, and the arm cuff deflates automatically.
If you do not have a session waiting for you to complete on your telehealth
appliance, and you want to measure your blood pressure now, press the
START button on your blood pressure monitor. The arm cuff inflates. When the
measurement is complete, your blood pressure and pulse are displayed, and
the arm cuff deflates automatically.
4. Remove the arm cuff from your arm. If for any reason you need to measure
your blood pressure again, wait at least 10 minutes.
Then the backlight is on, And, announce and display the measurement value.
Your measurement is now complete. If you took a measurement during a session,
the bluetooth symbol on your blood pressure monitor blinks five times to indicate
that your measurement was transferred to your telehealth appliance.
If the bluetooth transition success, it will enter Turn Off mode after 60seconds timeout or press On/Off key. .
it is fail, and store the measurement data to memory. At the same time display EC20 for 25seconds, and then turn off.
11 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
6. Error messages on your blood pressure monitor
When you use your blood pressure monitor, it might display an error message to
indicate that a problem occurred.
The following table provides explanations of the error messages that you might
see on your blood pressure monitor and what you can do to try to resolve the
problem. If you cannot resolve a problem, contact your care provider.
Message
Description
EC02
The blood pressure monitor could not detect a stable
pressure signal. Try again
EC04
The cuff did not deflate properly. Try again
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 12
Message
EC10
EC20
EC87
Description
The blood pressure monitor was not able to connect to your
telehealth appliance. Place your blood pressure monitor
closer to your telehealth appliance, and try again
The blood pressure monitor could not transmit your
measurements to your telehealth appliance. Place your blood
pressure monitor closer to your telehealth appliance, ensure
that telehealth appliance is on, and then try again.
The cuff did not inflate properly. Check the cuff hose for leaks
or loose connections, adjust the cuff position, and then try
again
EC91
The blood pressure monitor could not detect a stable
pressure signal. Try again
EC92
An error occurred with the internal hardware of the blood
pressure monitor. Try again
13 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
Message
Description
EC98
An error occurred with the internal software of the blood
pressure monitor. Try again.
7. Symbols and Functional Features
Front of the blood pressure monitor
Symbol
Description
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 14
Please fill in the blank
Symbol
15 | en
Description
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
Top of the blood pressure monitor
Symbol
Description
Battery compartment (bottom)
Symbol
Description
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 16
Symbol
Description
8. Cleaning, maintenance, and disposal
To clean the blood pressure monitor, use a soft cloth dampened with water. Do
not use any chemical or scouring agents. Ensure that liquid cannot penetrate into
the blood pressure monitor.
If your blood pressure monitor requires maintenance, contact your care provider.
Contact your care provider regarding the disposal of your blood pressure monitor.
Ensure that old batteries are disposed of in an approved location, separately from
domestic waste.
17 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
9. Technical data
Measurement range: 20 – 250 mmHG
Protection class: IP21
Operating temperature: 41°F (5°C) to 104°F (40°C)
Relative humidity: 15%%-93%%;%%Atmospheric pressure: 80kPa-105kPa%%
Storage temperature: -13°F (-25°C) to 158°F (70°C)
Relative humidity: 15%%-93%%;%%Atmospheric pressure: 80kPa-105kPa%%
Power: 4 AA (R6P) batteries, 6V
Cuff size: 8.6 in x 12.6 in (22 cm x 32 cm)
Expected battery life: 3 months (with 2 measurement cycles per day)
Expected life of blood pressure monitor and cuff: 3 years
Pressure accuracy:
3 mmHG
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
en | 18
10. Regulatory
Intended Use: The Bosch Branded Blood Pressure Monitoring (BPM) System is
intended for use by adults, to measure systolic and diastolic pressures as well as
pulse rate, by the oscillometric method, in a telehealth system and for personal
home use.
Part 15
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment. Do not attempt to open or modify the device.
Note: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
19 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
20 | en
Robert Bosch Healthcare Systems, Inc. | F.03D.601.424 Rev. A 12/2012
Industry Canada Statement
This device complies with Industry Canada licence‐exempt RSS‐210. Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the
device.
This Class B digital apparatus complies with Canadian ICES‐003.
FCC ID: NMTBP5000BT
IC: 3277A‐BP5000BT
Canadian RepreSentative Information
Compamy Name: TJS Technical Services Inc.
Adress: 203-304 Main Street Suite 160 Airdrie Alberta T4B 3C3 Canada
Contact Name: Thomas J Smith P.Eng
E‐mail Address: tsmith@tjstechnical.com
Telephone No.: (403)612-6664
Facsimile No.: (403)612-6664
This device complies with the following standards:
IEC 60601‐1:2005/AC:2010
IEC 60601‐1‐2:2007
ISO 81060‐2:2009
IEC 80601‐2‐30:2009
I revise some cotent next page/
RoHS Compliance
WEEE Compliance
Bluetooth®
Consult Instructions for
Use
Use the blood pressure
monitor indoors only.
Tested to Comply
With FCC Standards
Contains FCC ID: R47F2M03GX
Keep dry.
BF symbol for “applied parts”
Keep away from heat.
Manufacturer:
Robert Bosch Healthcare Systems, Inc.
Shipping temperature
range.
F.03D.601.424 Rev. A 12/2012 | Robert Bosch Healthcare Systems, Inc.
2118 Beechgrove Pl.
Utica NY, 13501
USA
en | 22
WEEE Compliance
Consult Instructions for
Use
Use the blood pressure
monitor indoors only.
RoHS Compliance
Bluetooth®
EN 60950
Compliance
“
Keep away from heat.
Shipping temperature
range.
”
BF symbol for applied parts
Robert Bosch Healthcare Systems, Inc.
2118 Beechgrove Pl.
Utica NY, 13501
USA
en | 22
D
AF
Blood Pressure Monitor BP5000 BT

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-702
Create Date                     : 2012:12:05 15:03:50-08:00
Metadata Date                   : 2013:01:03 18:08:31+08:00
Modify Date                     : 2013:01:03 18:08:31+08:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:b4f1a080-353c-4c63-a508-1fa573d09cd1
Original Document ID            : xmp.did:5EFCBC894727E111B3E8E413F768D1EA
Document ID                     : xmp.id:B6E90AD32F3FE211AE9CE526A7246E48
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:968F42DD2A3FE211B91DCE07C64FA455
Derived From Document ID        : xmp.did:B5E90AD32F3FE211AE9CE526A7246E48
Derived From Original Document ID: xmp.did:5EFCBC894727E111B3E8E413F768D1EA
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2012:12:05 15:03:50-08:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 27
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NMTBP5000BT

Navigation menu