IDT Technology IH300-01 Instant Forecast Hub (433.92MHz Tx) User Manual i600 EN RUNNING UM R2 indd
IDT Technology Limited Instant Forecast Hub (433.92MHz Tx) i600 EN RUNNING UM R2 indd
User Manual
To activate / deactivate alarm ................................ 8 To silence alarm ..................................................... 8 Backlight ................................................................... 8 Reset .......................................................................... 8 Specifications ........................................................... 9 Precautions ............................................................... 9 About Oregon Scientific ........................................ 10 EU-Declaration of Conformity ............................... 10 FCC Statement .........................................................11 Declaration of conformity ..................................... 11 USER MANUAL CONTENTS Introduction............................................................... 2 Packaging contents.................................................. 2 Overview.................................................................... 3 Front view ............................................................... 3 Back view ............................................................... 3 USB communications hub ...................................... 4 Outdoor thermo-hygro sensor ................................ 4 Getting Started.......................................................... 4 Set up remote sensor ............................................. 4 Set up main unit ..................................................... 5 Set up software (first time use) ............................... 6 Windows XP ........................................................... 6 Windows Vista ........................................................ 6 Disable sleep mode .................................................. 6 To disable sleep mode on computer (Windows XP ) ....................................................... 6 To disable sleep mode on computer (Windows Vista) ..................................................... 7 Set up USB communications hub ........................... 7 Main unit screen display .......................................... 7 To change display modes ....................................... 7 To view different warning messages ...................... 8 Weather forecast .................................................... 8 Clock .......................................................................... 8 To manually set clock ............................................. 8 Alarm ......................................................................... 8 To set alarm ........................................................... 8 EN Global 5-Day Weather Adviser II Model: I600 i600_EN_RUNNING_UM_R2.indd 1 2008.7.22 5:50:30 PM EN INTRODUCTION PACKAGING CONTENTS Thank you for selecting the Oregon Scientific™ Global 5-Day Weather Adviser II (I600). The weather station is capable of connecting to a PC computer using the USB connection. By installing the PC software, world cities can be user-selectable. The software can also download and display the latest weather data and time of the selected cities. 3 x AA UM-3 1.5V Batteries For full details see software instructions. 1 x Main Unit PC system requirements The minimum system requirements for use of the software is: • Operating system: Microsoft Windows XP SP2 or Vista • Processor: Pentium 4 or above • RAM: Min. 512MB • Hard disk free space: Min. 512MB • Screen Display Area: 1024 x 768 pixels (recommended) 2 x AAA UM-4 1.5V Batteries 1 x USB Communications Hub NOTE The USB is only used for the uploading and downloading of weather data. It is not to be used for charging battery power. 1 x Remote Sensor 1 x USB Cable NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. i600_EN_RUNNING_UM_R2.indd 2 2008.7.22 5:50:41 PM BACK VIEW FRONT VIEW 1 234 EN OVERVIEW 10 11 12 13 1. : Information signal reception indicator 2. : Indicate AM / PM 3. : Indicate daily alarm is On 4. : Indicate alarm time is displayed 5. : Main unit batteries low 6. City name / Clock / Calendar / Scrolling warning message 7. Today’s weather forecast (home environment) 8. Today’s regional weather forecast (user selected city) 9. : Indicate outdoor sensor reception status 10. : Sensor batteries low 11. Current indoor / outdoor temperature / humidity (home environment) 12. Today’s regional HI / LO temperature (user selected city) 13. Next 4 day regional weather forecast with HI / LO temperature (user selected city) i600_EN_RUNNING_UM_R2.indd 3 1. SNOOZE · MESSAGE: Activate snooze alarm; turn on backlight; toggle between city / weather warning / advisory message 2. ALARM: Change settings / display; activate/deactivate alarm; set alarm 3. MODE: Toggle between calendar display and currently selected city; set clock 4. UP: Initiate sensor search; increase value of the setting; display next city’s data 5. DOWN: Decrease value of the setting; display previous city’s data 6. Wall mount holes 7. RESET: Reset unit to default settings 8. ºC / ºF: Select temperature unit 2008.7.22 5:51:00 PM EN USB COMMUNICATIONS HUB FRONT VIEW OUTDOOR THERMO-HYGRO SENSOR BACK VIEW FRONT VIEW BACK VIEW Front View: 1. LED status indicator: Blink when transmitting a reading Front View: 1. LED status indicator: Blink during registration with main unit or during sensor search; indicate a successful USB connection Back View: 1. RESET: Reset unit to default settings 2. Channel switch 3. Battery compartment Back View: 1. SEARCH: Initiate search for remote sensors 2. RESET: Reset USB Communications Hub to default settings 3. USB port: Upload / download records to / from PC GETTING STARTED SET UP REMOTE SENSOR 1. Slide open the battery door. 2. Select channel. 3. Insert the batteries, matching the polarities (+ / -) and press RESET. 4. Close the battery door. i600_EN_RUNNING_UM_R2.indd 4 2008.7.22 5:51:04 PM 5. Secure the sensor in the desired location using the wall mount bracket. EN For best results: • Place the sensor within 100 m (300 ft) of the USB Communications Hub and main unit. • Position the sensor so that it faces the USB Communications Hub and main unit, minimizing obstructions such as doors, walls and furniture. • Place the sensor out of direct sunlight and moisture. • Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects. • Position the sensor close to the USB Communications Hub and main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. NOTE • Install batteries in the remote sensor before installing the USB Communications Hub and main unit. • Press RESET after each battery change. TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. 6. Press SEARCH on USB Communications Hub to initiate search and start receiving data from the sensor. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. NOTE USB Communications Hub will search only for already registered sensor or new sensor reset within last 30 minutes. To register a new sensor, reset sensor prior to search. SET UP MAIN UNIT 7. Press and hold UP and DOWN on the main unit to initiate sensor search. NOTE Batteries should not be exposed to excessive heat such as sunshine or fire. 1. Remove the battery compartment cover. 2. Insert the batteries, matching the polarities. 3. Press RESET after each battery change. i600_EN_RUNNING_UM_R2.indd 5 2008.7.22 5:51:09 PM EN SET UP SOFTWARE (FIRST TIME USE) WINDOWS VISTA WINDOWS XP To Disable User Access Control (UAC): 1. From the desktop, My Computer > Control Panel > User Accounts and Family Safety > Change your Windows password > Turn User Account Control On or Off. 2. Deselect the UAC option by un-ticking. 3. Follow steps 1-8 from above section. To install software: 1. Run CD software provided. 2. Setup wizard dialogue box will appear and guide you through the installation process. 3. After successful installation, double click on desktop shortcut. 4. Click DISPLAY in Oregon Weather Station dialogue box. DISABLE SLEEP MODE To allow for continuous update of data, ensure Sleep Mode on computer is disabled. Select Cities: TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS XP) 1. Right click on Desktop. 2. Choose “Properties”. 3. Click on “Screen Saver” Tab in the Display Properties window. 4. Click on “Power” located at the bottom half of window. 5. A new window “Power Options Properties” will open. 6. Under “System standby” option, choose “Never” in drop down menu. 7. Click “Apply” and then click “OK”. 8. Previous window will return. Click “OK” to confirm and exit. 5. Click next to 5 day weather forecast. 6. On the new page that appears, there will be cities set as default. To change, click CHANGE. 7. In the Settings… dialogue box, City tab, select cities in the drop down menus (Region; Country / Area; City / US Zip). 8. Click OK. i600_EN_RUNNING_UM_R2.indd 6 2008.7.22 5:51:19 PM EN TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS VISTA) 1. Right click on Desktop. 2. Choose “Personalize”. 3. Click on “Screen Saver” Tab in the Display Properties window. 4. Click on “Change Power Settings” located at the bottom half of window. 5. Select “High Performance” and click “Change plan settings”. 6. Click “Change advanced power settings”. 7. Click “Sleep” and click “Hibernate after”. 8. Click “Setting” and set “0” minutes. 9. Click “Apply” and then “OK”. There is a registration mode with the main unit when the USB Communications Hub is turned on the first time, or after each installation. IMPORTANT Registration can take half an hour. Do not turn off computer / disconnect USB from computer during this time. SET UP USB COMMUNICATIONS HUB NOTE Set up the remote sensor before installing the USB Communications Hub. Continuous display of successful. Approximately 30 minutes daily connection to computer is sufficient to receive current weather data. For continuous use, always connect the USB Communications Hub to the computer using the USB cable provided. MAIN UNIT SCREEN DISPLAY TO CHANGE DISPLAY MODES To toggle between 5 cities: Press UP or DOWN. i600_EN_RUNNING_UM_R2.indd 7 indicates data transfer is To view alarm time and status: Press ALARM. To toggle between calendar display and currently selected city: Press MODE. 2008.7.22 5:51:21 PM EN TO VIEW DIFFERENT WARNING MESSAGES ALARM Press SNOOZE · MESSAGE. TO SET ALARM 1. 2. 3. 4. WEATHER FORECAST For your convenience there is an enclosed sheet listing individual weather icons and their respective meanings. Press ALARM to enter Alarm mode. Press and hold ALARM to enter settings. Press UP / DOWN to set hour / minute. Press ALARM to confirm settings. TO ACTIVATE / DEACTIVATE ALARM The number of days with weather forecast available is dependent on data provided by local observatories. 1. Press ALARM to enter Alarm mode. 2. Press ALARM repeatedly until desired option is displayed ( / “OFF”). 3. Press MODE to confirm and return to clock display. CLOCK TO MANUALLY SET CLOCK TO SILENCE ALARM NOTE This product is designed to synchronise its calendar clock automatically with the information downloaded from the PC. • Press SNOOZE · MESSAGE to silence it for 8 minutes. OR • Press any key to turn the alarm off and activate it again after 24 hours. 1. Press and hold MODE to enter settings. 2. Press UP / DOWN to change settings. 3. Press MODE to confirm settings. BACKLIGHT Press SNOOZE · MESSAGE to activate LED backlight for 8 seconds. The settings order is: 12/24 hour format, hour, minute, year, month-day / day-month, month, day and language. RESET NOTE The language options are English (ENG), German (GER), French (FRE), Italian (ITA), Spanish (SPA) and Russian (RUS). Press RESET to return to the default settings. i600_EN_RUNNING_UM_R2.indd 8 2008.7.22 5:51:21 PM OUTDOOR REMOTE THERMO-HYGRO SENSOR MAIN UNIT LxWxH Dimensions (L x W x H) Weight Power 189 x 42 x 119 mm (7.4 x 1.7 x 4.7 in) 350 g (12.35 oz) without battery 3 x UM-3 (AA) 1.5V batteries Weight Temperature range Temperature resolution Humidity range Humidity resolution Signal frequency Transmission range Transmission period Number of channels Power INDOOR TEMPERATURE Temperature unit Displayed range Operating range Resolution °C / °F 0°C to 50°C (32°F to 122°F) -5°C to 50°C (23°F to 122°F) 0.1°C (0.2°F) INDOOR RELATIVE HUMIDITY Displayed range Operating range Resolution Weight Signal frequency Transmission range Information update Registration period Power 62 x 20 x 90 mm (2.4 x 0.8 x 3.5 in) 50 g (1.76 oz) without battery -20°C to 60°C (-4°F to 140°F) 0.1°C (0.2°F) 5% to 95% 1% 433 MHz 100 m (300 ft) unobstructed Approximately every 60 seconds 2 x UM-4 (AAA) 1.5V batteries CLOCK / CALENDAR 2% to 98% 25% to 90% 1% Clock display Hour format Calendar USB COMMUNICATIONS HUB Dimensions (L x W x H) EN SPECIFICATIONS HH:MM 12hr AM/PM or 24hr DD/MM or MM/DD PRECAUTIONS 68 x 46 x 136 mm (2.7 x 1.8 x 5.4 in) 92 g (3.2 oz) without battery 433 MHz 100 m (300 ft) unobstructed Approximately every 10 minutes Approximately 20 minutes Via PC through USB cable • • • • • Do not subject the unit to excessive force, shock, dust, temperature or humidity. Do not cover the ventilation holes with any items such as newspapers, curtains etc. Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. Do not clean the unit with abrasive or corrosive materials. Do not tamper with the unit’s internal components. This invalidates the warranty. i600_EN_RUNNING_UM_R2.indd 9 2008.7.22 5:51:22 PM EN • • • • • • • Only use fresh batteries. Do not mix new and old batteries. Images shown in this manual may differ from the actual display. When disposing of this product, ensure it is collected separately for special treatment and not as normal household waste. Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information. The contents of this manual may not be reproduced without the permission of the manufacturer. Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use. ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you’re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/support For international inquiries, please visit: www2.oregonscientific.com/about/international EU-DECLARATION OF CONFORMITY Hereby, Oregon Scientific, declares that this Global 5Day Weather Adviser II (Model: I600) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. COUNTRIES RTTE APPROVAL COMPLIED All EU countries, Switzerland CH and Norway N NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer. 10 i600_EN_RUNNING_UM_R2.indd 10 2008.7.22 5:51:22 PM This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com, or on the warranty card for this product) for all inquiries instead. We Name: Address: NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. i600_EN_RUNNING_UM_R2.indd 11 Consult the dealer or an experienced radio / TV technician for help. EN • FCC STATEMENT Telephone No.: Oregon Scientific, Inc. 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA 1-800-853-8883 declare that the product Product No.: I600 Product Name: Global 5-Day Weather Adviser II Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. 11 2008.7.22 5:51:22 PM EN Global 5-Day Weather Adviser II Model: I600 USER MANUAL 12 i600_EN_RUNNING_UM_R2.indd 12 2008.7.22 5:51:23 PM EN 13 i600_EN_RUNNING_UM_R2.indd 13 © 2008 Oregon Scientific. All rights reserved. 086L005367-011 2008.7.22 5:51:23 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 13 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:be7da51e-57d3-11dd-a0f0-000d93af1aa4 Create Date : 2008:06:05 14:16:41Z Metadata Date : 2008:07:22 17:51:23+08:00 Modify Date : 2008:07:22 17:51:23+08:00 Creator Tool : Adobe InDesign CS (3.0) Rendition Class : proof:pdf Derived From Instance ID : 4fe99609-28d0-11dd-8057-987b518bf63e Derived From Document ID : adobe:docid:indd:ba3a7ef5-22af-11dd-98c5-95231439df29 Document ID : adobe:docid:indd:362f9047-3499-11dd-9d3d-8a1d9ef4a37c Manifest Link Form : ReferenceStream Manifest Reference Instance ID : uuid:18af7d18-310a-11dd-8562-000d93af1aa4 Manifest Reference Document ID : uuid:DC2847032FBB11DDA30C831BDDD38694 Format : application/pdf Title : i600_EN_RUNNING_UM_R2.indd Trapped : False Creator : Adobe InDesign CS (3.0) Producer : Adobe PDF Library 6.0EXIF Metadata provided by EXIF.tools