IDT Technology RTGR328N-01 Remote Thermo-Hygro Sensor w/ RF Clock (433MHz Tx) User Manual MODEL RA313PA

IDT Technology Limited Remote Thermo-Hygro Sensor w/ RF Clock (433MHz Tx) MODEL RA313PA

User Manual

   Weather Station Model: BAR990HG  USER MANUAL  INTRODUCTION Thank you for selecting the Oregon ScientificTM Weather Station.  NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about.  OVERVIEW FRONT VIEW / LCD DISPLAY   1.  SNOOZE / LIGHT: Activate 8-minute snooze or backlight  2.  Weather Forecast Area 3.  Temperature, Humidity and Comfort Zone Area 4.  UVI and Barometer Area 5. Clock Area 6.  CHANNEL: Switch remote sensor display 7.  MODE: Change settings / display 8.  SELECT: Switch areas 9.  ALARM: View alarm status; set alarm 10.  HIST: View historical barometer and UV readings 11.  MIN/MAX: View current, maximum and minimum temperature / humidity / UV readings  BACK VIEW    1.   /  Adjust settings; activate / deactivate  clock reception 2.  RESET: Reset the unit 3.  Battery compartment 4.  °C / °F: Select temperature unit 5.  mb / Hg: select pressure unit   LCD Weather Forecast Area  1.  Main unit battery low  2.  Weather Forecast  Temperature and Humidity Area   1.  Selected Area icon 2. Temperature trend  3.  Channel number (1-5) / reception status  4.  Low battery icon for remote sensor 5. Humidity trend 6.  MAX / MIN temperature  7.  Temperature - °C / °F  8.  Heat Index  9.  MAX / MIN humidity  10. Humidity  11. Humidity Comfort levels  UVI / Barometer Area  1.  Barometric pressure is showing  2.  UV is showing  3.  Low battery icon for UV sensor  4.  UVI value is showing  5.  UV exposure time countdown has started.  6.  UV index level   7.  UV exposure time for user   8.  Barometer / UV chart  9.  SPF applied to user for UV exposure   10.  User skin type for UV exposure  11.  User no. (for UV Mode) or hour history for UV / Barometric pressure reading  12.  Altitude / barometric pressure / UVI reading  Clock Area  1. Pre-Alarm is set 2.  Pre-Alarm display / Pre-Alarm setting 3.  Channel with clock reception is locked 4. Clock reception icon 5.  Daily Alarm is set 6. Offset time-zone 7.  Time / date / calendar  REMOTE SENSOR    1. LCD display 2. LED status indicator 3. Ventilation duct   1. Wall mount 2.  CHANNEL: select sensor channel 3.  RESET 4. °C / °F: select temperature unit 5.  SEARCH: search for clock reception 6.  EU / UK: select clock signal 7. Battery compartment 8. Stand  REMOTE SENSOR LCD  1. Signal reception 2. Channel number 3.  Low battery icon 4. Time 5.  Temperature unit (°C or °F) 6. Humidity % 7. Temperature / Humidity  GETTING STARTED BATTERIES Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit. Press RESET after each battery change.     indicates main unit batteries are low.  NOTE Do not use rechargeable batteries. We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing  UNIT   LOCATION Main  Weather Forecast Area Remote sensor  Temperature, Humidity and Comfort Zone Area UV sensor  UVI and Barometer Area  Stand / Wall Mount:    REMOTE SENSOR SET UP SENSOR The main unit can collect data from up to 5 Thermo / Hygro Sensors and 1 UV Sensor.  (Additional sensors are sold separately. Contact your local stockist for more information.)  To set up the thermo-hygro sensor: 1.  Open the battery compartment with a small Phillips screwdriver. 2.  Insert the batteries. 3.  Slide CHANNEL on the sensor to select a channel. Make sure you use a different channel for each sensor. 4. Slide EU / UK to your location. 5. Press RESET. 6.  Close the battery compartment. 7.  Secure the sensor in the desired location using the table stand or wall mount.    For best results: •  Place the sensor out of direct sunlight and moisture.  •  Do not place the sensor more than 30 m (100 ft) from the main (indoor) unit. •  Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls, and furniture. •  Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects. •  Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission.  The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.  Standard Alkaline batteries contain significant amounts of water. Because of this they will freeze in low temperatures of approximately -12°C (10°F). Disposable Lithium batteries have a much lower threshold for temperature with an estimated freezing range of below -30°C (-22°F).  Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures. Extreme cold may temporarily reduce the effective range between the sensor and the base station. If the unit's performance fails due to low temperature, the unit will resume proper functioning as the temperature rises to within the normal temperature range (i.e. no permanent damage will occur to the unit due to low temperatures).  SENSOR DATA TRANSMISSION ICON DESCRIPTION  Main unit is searching for the sensor(s)  A channel has been found  Sensor 1 is sending data  and “- - . -“ (Temperature / Humidity display) The sensor cannot be found. Search for the sensor or check batteries  To search for a sensor:  1. Press SELECT to navigate to the Temperature, Humidity and Comfort Zone Area.  2.  Simultaneously, press and hold MEM and CH for 2 seconds.  NOTE If the sensor is still not found, check the batteries, obstructions, and remote unit location.  UV SENSOR (OPTIONAL) Refer to the UV sensor User Manual for information on set-up.   To search for a UV sensor:  1. Press SELECT to navigate to UVI and Barometer Area. 2.  Simultaneously, press and hold MEM and CH for 2 seconds.  CLOCK CLOCK RECEPTION This product is designed to synchronize its calendar and clock automatically. The sensor collects the data and transmits them to the main unit once it is brought within range of a radio signal:  •  DCF-77 generated from Frankfurt, Germany for Central Europe. •  MSF-60 generated from Rugby, England.  The radio signal range is 1500km (932 miles).  CLOCK RECEPTION SIGNAL Initial reception takes 2-10 minutes for first set up or when RESET is pressed. Once complete, the reception icon will stop blinking. If the signal is weak, it can take up to 24 hours to get a valid signal.  ICON DESCRIPTION  Connection between main unit and sensor collecting signals  Sensor signal reception  Main unit has contacted sensor; time is synchronised  Main unit has contacted sensor; time is not synchronised  Main unit has lost contact with sensor; time is synchronised  Main unit has lost contact with sensor; time is not synchronised  Main unit cannot contact sensor No icon  Clock reception disabled  To enable clock signal reception: 1. Press SELECT to navigate to the Clock Area. 2.  In clock mode, Press and hold   for two seconds.  To disable clock signal reception: 1. Press SELECT to navigate to the Clock Area. 2.  In clock mode, Press and hold   for two seconds.  SET CLOCK You only need to do this if you have disabled the clock signal reception or are out of range.  1. Press SELECT to navigate to the Clock Area. 2.  Press and hold MODE for 2 seconds. 3. Press   or   to change the setting. 4. Press MODE to confirm. 5.  The setting order is: time zone offset hour (+ / -23 hours),12 / 24 hour format, hour, minute, year, date / month format, month, date and display language.  NOTE The language options are (E) English, (F) French, (D) German, (I) Italian, and (S) Spanish.   DISPLAY Press SELECT to navigate to the Clock Area, then press MODE to toggle display between: •  Clock with seconds •  Clock with day •  Clock with time-zone •  Calendar  ALARM This product has 2 alarms: The daily alarm and a pre-alarm for snowy weather.  SET DAILY ALARM 1. Press SELECT to navigate to the Clock Area. 2. Press ALARM to enter alarm mode, AL will appear. 3.  Press and hold ALARM for 2 seconds. 4.  Select the hour and minute. Press   or   to change settings. 5. Press ALARM to confirm.   indicates the daily alarm is set.  SET PRE-ALARM The pre-alarm activates a set time before the daily alarm. It will only sound if the recorded temperature from Channel 1 Sensor falls to 2°C (35.6°F) or below.   For example, if you set the daily alarm to 7:00 AM, and the pre-alarm to 45 minutes, the pre-alarm will sound at 6:15 AM provided the  outdoor temperature at Channel 1 Sensor is 2°C or below.  1.  Set up and activate the daily alarm. 2. Press ALARM to switch to pre-alarm view, PRE-AL will appear. 3.  Press and hold ALARM for 2 seconds. 4. Press    or   to select 15, 30, 45 or 60 minutes.  5.  The pre-alarm is automatically activated when you select a time. 6. Press ALARM  to confirm.   indicates the pre-alarm is set  NOTE The daily alarm will NOT function until the next day if the pre-alarm has been triggered. Also, if you deactivate the daily alarm, the pre-alarm is automatically deactivated.  ACTIVATE / DEACTIVATE ALARMS 1. Press SELECT to navigate to the Clock Area, then press ALARM to select the daily or pre-alarm. 2. Press   to activate or   to deactivate the alarm.  To silence the alarm: •  Press SNOOZE / LIGHT to silence it for 8 minutes. OR •  Press any other key to turn the alarm off and activate it again after 24 hours.   BAROMETER This product tracks fluctuations in barometric pressure to provide the weather forecast, and the current and past 24 hours barometric pressure history measurements are recorded by the main (indoor) unit.  VIEW BAROMETER DATA 1. Press SELECT to navigate to the UVI / Barometer Area.  2. Press MODE to toggle UVI / Barometer display.   indicates barometer information is displayed. 3.  The bar chart display shows atmospheric changes over the past 24 hours. The lower display shows the current or historical reading.   To select the unit of measurement: Press mb / inHg.  To view barometer history: 1. Press SELECT to navigate to the UVI / Barometer Area. 2. Press HIST to scroll through saved records.  shows how long ago the measurement was taken.  SET ALTITUDE To ensure barometric readings are reliable set the altitude to reflect distance from sea level at your position.  1. Press SELECT to navigate to the UVI / Barometer Area. 2.  Press and hold HIST for 2 seconds. 3. Use   and   to set the altitude in 10 M (33 ft) increments from -100 m (-328 ft) to 2500 m (8202 ft). 4. Press HIST to confirm.  NOTE The maximum operating altitude for the barometer and weather forecast is 2500m (8202 ft).   WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius based on barometric pressure trend readings.  ICON DESCRIPTION Clear  (Day / Night)    Partially   Cloudy (Day / Night)  Cloudy  Rainy  Snowy  UV MEASUREMENT UV data is shown in the same area as the Barometer. To view UV data please purchase a compatible UV Sensor (ask your retailer for further information).  1. Press SELECT to navigate to the UVI / Barometer Area. 2. Press MODE to display UV data.   indicates UV data is displayed. 3.  The bar chart display shows UV Index changes over the past 24 hours. The lower display shows the current or historical reading.   NOTE Refer to the UV sensor User Manual for information.  To view UVI history: 3. Press SELECT to navigate to the UVI / Barometer Area. 4. Press HIST to scroll through saved records.  shows how long ago the measurement was taken.  UV EXPOSURE TIME COUNTDOWN To set the exposure time countdown you need set to the Skin Type and Sun Protection Factor (SPF) as follows:  1.  In UVI display, press CHANNEL to select user 1-4. 2. Press and hold MODE for 2 seconds.  3. Press  or   to enter the setting. 4. Press MODE to confirm. 5.  The settings order is: skin type, SPF (sun protection factor used), countdown activated / deactivated. 6.  Once the countdown is activated   will flash and the time remaining will appear. 7.  When the countdown has reached "0", an alarm will sound for 2 minutes. Press any button to turn the alarm off. The icon will flash for 2 minutes.  SKIN TYPE  TANS / BURNS  SKIN COLOUR IN UNEXPOSED AREA EYE  COLOUR 1  Never tans;  always burns  Pale or milky white; alabaster Blue 2 Sometimes tans;  usually burns Very light brown; sometimes freckles Blue / Green 3 Usually tans;  sometimes burns Light tan, brown or olive; distinctly pigmented Gray / Brown 4  Always tans;  rarely burns  Brown, dark brown or black Brown  NOTE Due to the many other factors that may influence the emission of and your tolerance to UV radiation, you are advised to consult your doctor or dermatologist before engaging in any activity involving extended exposures to UV rays and Oregon Scientific is not responsible for any results or consequences of relying on the product’s suggestions.  TEMPERATURE AND HUMIDITY The sensor reception icon indicates the temperature data displayed: •   for indoor temperature  •    for outdoor temperature (number indicates the sensor channel displayed)  Press SELECT to navigate to the Temperature and Humidity Area.  To view outdoor sensors temperature / humidity readings: Press CHANNEL.   To toggle temperature unit: Press °C / °F.  To auto-scan between sensors: Press and hold CHANNEL for 2 seconds. Each sensor’s data is displayed for 3 seconds.  To end auto-scan: Press CHANNEL or MIN / MAX.  To toggle between minimum and maximum records for the selected sensor: Press MIN / MAX repeatedly.  To clear the records:
 Press and hold MEM for 2 seconds. TEMPERATURE AND HUMIDITY TRENDS The trend icons are based on recent readings.  RISE STEADY FALL     COMFORT ZONE The comfort zone assesses the climate based on the current temperature and humidity. It is shown beside the humidity display.  ICON TEMPERATURE  HUMIDITY WET  Any > 70% COM  20 - 25°C (68 - 77°F)  40 - 70% DRY  Any < 40%  HEAT INDEX The heat index combines temperature and humidity data to describe the actual temperature felt.  WARNING HEAT INDEX  MEANING Extreme danger  54.5°C / 130°F or above   Strong risk of dehydration / sun stroke Danger 105- 129°F/ 40.5- 3.9°C  Heat exhaustion likely Extreme caution  90- 104°F / 32.2 - 40°C  Possibility of heat dehydration Caution  80- 89°F / 26.6-31.7°C  Possibility of heat exhaustion  To display the Heat Index: 1. Press SELECT to navigate to the Temperature and Humidity Area. 2. Press MODE to reach the Heat Index display. 3.  Press CHANNEL to select the desired channel. S BACKLIGHT Press SNOOZE / LIGHT to activate the backlight for 8 seconds.  RESET To return the unit to the default settings, press RESET.  PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: •  Placement of this product on wood surfaces with certain types of finishes, such as clear varnish, may result in damage to the finish. Consult the furniture manufacturer's care instructions for direction as to the types of objects that may safely be placed on the wood surface. Oregon Scientific shall not be responsible for any damage to wood surfaces from contact with this product. •  Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. •  Do not clean the unit with abrasive or corrosive materials.  •  Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts. •  Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts. •  Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. •  Due to printing limitations, the displays shown in this manual may differ from the actual display. •  The contents of this manual may not be reproduced without the permission of the manufacturer.  NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.  TROUBLESHOOTING  Problem Remedy Strange barometer readings  Set the altitude / unit  Can’t adjust clock setting   Disable clock signal reception Can’t receive clock signals •  Adjust batteries •  Press RESET •  Activate clock signal reception Can’t locate remote sensor  Check batteries  SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT L x W x H  120 x 86 x 188 mm (4.7 x 3.4 x 7.4 in) Weight  376 g (13.3 oz) Temperature unit  °C / °F Indoor temperature range  -5°C to 50°C  (23°F to 122°F) Outdoor temperature range  -20°C to 60°C  (-4°F to 140°F) Temperature Resolution  0.1°C (0.2°F) Indoor Humidity range  25% to 95% Temperature Resolution  1% Weather display  Rainy, cloudy, partly cloudy, sunny Clock signal frequency  433 MHz Clock display format  12 or 24 hour format  Clock display  HH:MM:SS Alarm duration  2 minutes Snooze 8 minutes Channels 5 Power  4 x UM-3 (AA) 1.5 V batteries REMOTE SENSOR (RTGR382N) L x W x H  70 x 25 x 116 mm (2.8 x 1.0 x 4.6 in) Weight  108 g (3.8 oz) Range   70 m (230 ft) Power  2 x UM-3 (AA) 1.5 V batteries  ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children’s electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as frequently asked questions and customer downloads.  We hope you will find all the information you need on our website, however if you’re in the US and would like to contact the Oregon Scientific Customer Care department directly, please visit: www2.oregonscientific.com/service/default.asp  OR Call 1-800-853-8883.  For international inquiries, please visit: www2.oregonscientific.com/about/international.asp EU-DECLARATION OF CONFORMITY Hereby, Oregon Scientific, declares that the Weather Station Model: BAR990HG  is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.    FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.  WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio / TV technician for help.  DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com), or on the warranty card for this product) for all inquiries instead.  We Name: Oregon Scientific, Inc. Address: 19861 SW 95th Ave.,Tualatin,  Oregon 97062 USA Telephone No.:  1-800-853-8883  declare that the product  Product No.:  BAR990HG Product Name:   Weather Station Manufacturer:  IDT Technology Limited Address:  Block C, 9/F, Kaiser Estate,   Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong  is in conformity with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

Navigation menu