IONICS EMS IOTADV IOT PLATFORM User Manual Doc 53 15 IoT Platform Advance v0 00

IONICS EMS, INC IOT PLATFORM Doc 53 15 IoT Platform Advance v0 00

Users Manual.pdf

Download: IONICS EMS IOTADV IOT PLATFORM User Manual Doc 53 15 IoT Platform Advance  v0 00
Mirror Download [FCC.gov]IONICS EMS IOTADV IOT PLATFORM User Manual Doc 53 15 IoT Platform Advance  v0 00
Document ID3655389
Application IDM6EgmKuJ35+F+x/pwBvEpg==
Document DescriptionUsers Manual.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize143.14kB (1789204 bits)
Date Submitted2017-11-28 00:00:00
Date Available2017-11-29 00:00:00
Creation Date2017-10-12 18:57:19
Producing SoftwareGPL Ghostscript 9.07
Document Lastmod2017-10-12 18:57:19
Document TitleDoc.53-15 IoT Platform Advance User Manual v0.00
Document CreatorPDFCreator Version 1.7.0
Document Author: leo.mirabuna

Ionics EMS, Inc.
IoT Platform Advance
User Guide
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 1 of 13
Ionics EMS, Inc. Confidential
Ionics EMS, Inc. Confidential
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Ionics EMS, Inc.
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Product Key Features…………………………………………….……………………………..1
Quick Setup Guide……….……………………………………………………………..……….5
Advance Functional Setup…………………………………………………………………..…..6
Mounting Options……………………………………………….……………………………...10
Regulatory Information……………………………………………………………….………..12
Contact Us………………………………….………………………………..…………………..13
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 2 of 13
Ionics EMS, Inc. Confidential
1.
2.
3.
4.
5.
6.
Ionics EMS, Inc. Confidential
Contents
Ionics EMS, Inc.
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Ionics EMS, Inc. Confidential
1. Product Key Features
Description
Memory
Internal Storage
LAN
Button
USB
microSD
Debug
Debug
LED
Wi-Fi/BT
IEEE 802.15.4 Sub Ghz
RFM900
NXP I.MX6 Dual Lite
2GB DDR3L SDRAM, 400
MHz
8GB eMMC
2 x Gigabit Ethernet
1 x Hardware Reset Button
1 x Software Reset Button
2 x USB2.0 Port
2 x microSD Card Port
1 x Debug Console Port
1 x Programming Port
6 x Status LED
1 x 802.11 b/g/n 2.4 GHz /
BT 2.1 +EDR, BT 4.0
1 x 908 MHz Module
1 x 915 MHz RFM900
Module
Power Supply
9V-12V DC, 2A
The Internet-of-Things (IoT) Platform Advance implements a modular design which makes use of
interchangeable features like the system-on-modules (SOM), carrier boards, radio frequency (RF)
modules, sensor modules, and optional enclosures. Additional modules can be added using a
mikroBus™ connector. Note that this IoT Platform Advance is a hardware and software development
platform, end user or developer must still need to develop its own application on top of the existing
operating system of the unit.
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 3 of 13
Ionics EMS, Inc. Confidential
Processor
Ionics EMS, Inc.
1 – AC-DC 4-pins header Power Supply
2 – AC-DC Barrel Type Power Supply
3 – 2 x USB Port
4 – Local Area Network (LAN) port
5 – Wide Area Network (WAN) port
6 – micro SD card slot
7 – Screw Hole
8 – Hardware Reset Button
9 – External Antenna Connector
10 – Console UART port
11 – USB OTG port
12 – LED Indicators
13 – GPIO Button
Warning: The AC-DC power supply slot must not be used simultaneously if provided
or bought with both connector open. Either use one of the port
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 4 of 13
Ionics EMS, Inc. Confidential
Ionics EMS, Inc. Confidential
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Ionics EMS, Inc.
1. Connect the AC-DC Adapter to the IoT Platform Advance. Make sure you
plug in on the correct port.
2. To check for the console output and interact with the IoT Platform Advance,
connect the microUSB connector the Console port of the unit as shown
below.
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 5 of 13
Ionics EMS, Inc. Confidential
2. Quick Setup Guide
Ionics EMS, Inc. Confidential
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Ionics EMS, Inc.
Warning: Please note that power supply must be connected first before
connecting the microUSB connector. If the unit needs to be powered off by
unplugging the power supply, make sure to unplug the microUSB connector as
well, and connect the power supply first before the the microUSB cable.
If ask for the Windows driver, you can download the Windows Certified driver
at FTDI website located here http://www.ftdichip.com/Drivers/D2XX.htm .
Note that this Windows driver is owned by FTDI, licensing, warranties or
installation is governed by FTDI regulation. Installation issues that can be
associated with the hardware can be inquired through our support channel at the
end of this document.
3. On host PC, open up any preferred serial terminal console application (i.e
Teraterm) and access the IoT Platform Advance serial console port with the
following setting: Baudrate: 115200, Databit: 8, Parity: None, Stop Bit: 1
and No Flow Control.
4. On host terminal console, once prompted with username and password,
enter following information:
Username: root
Password: root
Ionics EMS, Inc. Confidential
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
5. The IoT Platform Advance platform can now be used for development of
applications and software on top of the pre-installed operating system.
This functional setup will check that all ports and functions is working upon the
initial setup of the device.
1. USB Function
To check if USB port is working, insert USB stick in the port. And check in
the console if it was detected. Additional test can be performed by issuing
commands in the console.
Example:
root@xenial:~# lsusb
Bus 001 Device 002: ID 0781:556b SanDisk Corp.
Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. Hub
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 6 of 13
Ionics EMS, Inc. Confidential
3. Advance Functional Setup
Ionics EMS, Inc.
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
root@xenial:~# mount /dev/sda1 /mnt or dev/sdb1 /mnt
Once mounted you can use the mount point /mnt to work with as an additional
storage of the device.
2. Ethernet Ports
Ionics EMS, Inc. Confidential
Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root
hub
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 7 of 13
Ionics EMS, Inc. Confidential
The Ethernet port is configured as WAN and the other for local area
network, they are labeled well in the enclosure of the unit.
Ionics EMS, Inc.
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Example:
root@xenial:~# blockdev --getsize64 /dev/mmcblk2 | awk '{ split(
"KB MB GB" ,v ); s=1; while( $1>1024 ){ $1/=1024; s++ } print $1
v[s-1] }'
root@xenial:~# mount /dev/mmcblk2p1 /mnt/
root@xenial:~# dd if=/dev/zero of=/mnt/write-test bs=8k
count=10k
4. WLAN
To check for Wi-Fi module is working. The WLAN module is a USB
device. List the available USB devices to verify that the module is detected.
Example:
root@xenial:~# lsusb
Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. Hub
Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
Bus 002 Device 002: ID 0bda:b720 Realtek Semiconductor Corp.
Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
root@xenial:~# ifconfig wlan0
wlan0 Link encap:Ethernet HWaddr 38:1d:d9:96:66:f9
inet addr:192.168.8.1 Bcast:192.168.8.255 Mask:255.255.255.0
inet6 addr: fe80::3a1d:d9ff:fe96:66f9/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:3976 errors:0 dropped:19 overruns:0 frame:0
TX packets:12 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:264 (264.0 B) TX bytes:640 (640.0 B)
root@xenial:~# iw dev wlan0 info
Interface wlan0
ifindex 4
wdev 0x1
addr 38:1d:d9:96:66:f9
ssid ionics_iot-9666f9
type AP
wiphy 0
5. CC1310
a. Server mode
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 8 of 13
Ionics EMS, Inc. Confidential
To check if microSD card port is working, insert microSD card in the port.
And check in the console if it was detected. Check for microSD card
information like size and do some basic read write test.
Ionics EMS, Inc. Confidential
3. microSD card slot
Ionics EMS, Inc.
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
b. Client mode
Set the module as 6LowPAN client.
Example:
root@xenial:~# /root/.setup/cc1310/ctrl_cc1310 -m 2 -n
client
Removing fd00::212:4b00:a29:46f4
Removing previous RPL Root...
Waiting for Server...
Information below will be seen if the client created a connection to server.
UDP-CLIENT: Server’s Address: fd00::212:4b00:a29:45fe
Created a connection with the server
Connected in 10 s
Sending data “Hello World” to server.
root@xenial:~# /root/.setup/cc1310/ctrl_cc1310 -m 2
-s ‘‘Hello World’’
Example:
root@xenial:~# /root/.setup/cc1310/ctrl_cc1310 -m 2 -s
‘‘Hello World’’
Client sending: ‘‘Hello World’’ to server
Server replied: Hi 244 from Server
6. RFM900
Basic Functionality check for the RFM900 module radio installed on the
unit. For this to work, another unit needs to be paired to the radio to do
some ping-pong testing. Set one device as a ping by issuing the below
command.
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 9 of 13
Ionics EMS, Inc. Confidential
Example:
root@xenial:~# /root/.setup/cc1310/ctrl_cc1310 -m 2 -n
server
Created new RPL dag
IPv6 Addresses:
fd00::212:4b00:a29:45fe
fe80::212:4b00:a29:45fe
CLIENT ID: HOPS: PAYLOAD: RSSI:
When the server receives data from client, additional lines like below would
be seen.
244 1 Hello World -15 dBm
Ionics EMS, Inc. Confidential
Set the module as 6LowPAN server.
Ionics EMS, Inc.
cd /root/.setup/rfm900/
./lpg.sh
siflexcon
trace -1
channel 1
power 10
ping 5 100
Set the other unit or device as pong by issuing the below command.
cd /root/.setup/rfm900/
./lpg.sh
siflexcon
trace -1
channel 1
power 10
pong 1
The two unit should now communicate.
4. Mounting Options
The gateway could be placed on the table as a desktop home router but the
user also has the option to attach the gateway to a wall via standard DIN
Rail. The recommended accessory connectors for this type of wall
mounting should be compatible with EN 50022 and EN 50035 standards.
Lastly, the gateway could also be attached to any solid surface using 4 x
screws fitted at each corner of the enclosure. Recommended screw size is
#8 (or 0.16” diameter).
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 10 of 13
Ionics EMS, Inc. Confidential
Ionics EMS, Inc. Confidential
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Ionics EMS, Inc.
In a case where the IoT Platform Advance will be mounted to a different enclosure
and with a chassis mount power supply will be used having the same rating as stated
in the product key features following mounting option is recommended to the final
enclosure.
Ionics EMS, Inc. Confidential
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
withstand internal temperatures (inside the plastic enclosure) ranging from -40 to +70
oC.
However, for safety precautions the user is advised to operate the product at
outside ambient temperatures not lower than -25 oC or higher than 55 oC.
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 11 of 13
Ionics EMS, Inc. Confidential
This product contains industrial grade components and accessories that could
Ionics EMS, Inc.
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
Ionics EMS, Inc. Confidential
5. Regulatory Information
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note: The country code selection is for non-US model only and is not available to all US model. Per
FCC regulation, all WiFi product marketed in US must fixed to US operation channels only.
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 12 of 13
Ionics EMS, Inc. Confidential
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body.
Ionics EMS, Inc.
#14 Mountain Drive, Light Industry and Science Park II,
Brgy. La Mesa, Calamba, Laguna, 4027, Philippines
+63 (49) 508 1111
contact our customer service through these channels:
Monday to Friday, 9am – 7pm
Email: sales@ionics-ems.com
Telephone: +63 49 508 1111
IoT Platform Advance User Guide
Author: Leo Mirabuna
Email: leo.mirabuna@ionics-ems.com Section: Quality Assurance
Date: September 29, 2017
Phone: +63495081111 local 403
Document No.:53-15
Rev. No.0.00
page 13 of 13
Ionics EMS, Inc. Confidential
If you have any issues or need assistance in setting up your IoT Platform Advance, you can
Ionics EMS, Inc. Confidential
Contact Us

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 13
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a0ac6f2a-b197-11e7-0000-b2696a7920b0
Producer                        : GPL Ghostscript 9.07
Keywords                        : ()
Modify Date                     : 2017:10:12 18:57:19+08:00
Create Date                     : 2017:10:12 18:57:19+08:00
Creator Tool                    : PDFCreator Version 1.7.0
Document ID                     : uuid:a0ac6f2a-b197-11e7-0000-b2696a7920b0
Format                          : application/pdf
Title                           : Doc.53-15 IoT Platform Advance User Manual v0.00
Creator                         : leo.mirabuna
Description                     : ()
Author                          : leo.mirabuna
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Y6S-IOTADV

Navigation menu