IP Mobilenet EZPRO25RF EzPro P-25 Base Station radio/repeater User Manual

IP Mobilenet, LLC EzPro P-25 Base Station radio/repeater Users Manual

Users Manual

                           TTEECCHHNNIICCAALL  DDEESSCCRRIIPPTTIIOONN    AAPPCCOO  PP2255    EEZZPPRROO2255  RRFF  ––  IINNSSTTAALLLLAATTIIOONN  GGUUIIDDEE
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 2 of 21  Initial Release Revision: 00  INDEX       1. INTRODUCTION  32.  UNPACKING AND CHECKING  53. PREVIOUS CONSIDERATIONS    54.  INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY  55. EQUIPMENT DESCRIPTION  65.1 FRONT VIEW  75.2 REAR VIEW  85.3 MODULES  95.4  CABLING AND CONNECTORS  136. INSTALLATION GUIDE  146.1 LOCATION  146.2  POWER SUPPLY CONNECTION  146.3 ANTENNA CONNECTION  156.4  SWITCHING ON THE EZPRO25 RF  157. CONFIGURATION  168. INCIDENTS  168.1 ALARMS  168.2  ALARMS WITHOUT STATUS LEDS  19
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 3 of 21  Initial Release Revision: 00
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 4 of 21  Initial Release Revision: 00    1. INTRODUCTION  The EZPRO25 RF module (Base Station Repeater) are a modular design, high performance products used as APCO repeaters.  The radio system is available in the 806-870Mhz frequency band. The proper functioning of any electronic device depends on its correct use. It is therefore recommended that the instructions in this manual be followed.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 5 of 21  Initial Release Revision: 00   2. UNPACKING AND CHECKING  The following elements are supplied in the box:  EZPRO25 RF  2 cables SMB RF  Installation manual           The equipment is supplied with all the modules already assembled in the rack and with the RF cables connected. The modules in the basic configuration are: Control (RCPU P25), Transmitter (RTX P25), power module (RPA P25), Receiver (RRX P25) and the power supply module (RPS P25).  IMPORTANT: if any of these elements is missing or damaged, contact your dealer and / or installer.   3. PREVIOUS CONSIDERATIONS  This manual contains information on instructions for installation, maintenance and use. Read the following pages before using this equipment. It is inadvisable to switch on the equipment without having previously connected the antenna or, in case of the EZPRO25 RF, the 50Ω load to the TNC connector. Doing so may seriously damage the equipment and even cause irreparable damage to the transmitter circuits. It is important to use an antenna adjusted to the work frequency.  4. INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY The equipment has been designed according to the following standards:  ETSI ETS 300 392-2 - V2.5.2 (2005-11)  ETSI ETS 300 394-1 - V2.4.0 (2005-10)  ETSI EN 301 489-18 - V1.3.1 (2002-08)  EN 60950-1 - 2001  EN 60950-1:2001/A11:2004  EN 60215-1989  EN 60215:1989/A1:1992  EN 60215:1989/A2:1994
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 6 of 21  Initial Release Revision: 00   These standards ensure the essential requirements established in article 3 of directive 1999/5/CE. In any case, take the following points into consideration:      Most electronic equipment is susceptible to electromagnetic interference if it is not duly protected. If the EZPRO25 RF is placed near unprotected electronic devices, they may malfunction.  The EZPRO25 RF must not transmit without its antenna connected or, in case of the EZPRO25 RF, without the 50Ω load in the TNC connector.  When installing the antenna, follow the guidelines for exposure of the human body to high and low frequency electromagnetic fields. Follow the supplier’s / manufacturer’s instructions.  Burns may be suffered if the antenna connector output of the power module (RPA P25) is touched by bare skin when the EZPRO25 RF are transmitting with the antenna disconnected.  Take care when handling the EZPRO25 RF. It has sharp edges, which may cut if handled incorrectly.  Maintenance and repair of these repeaters must be carried out by qualified personnel only.  Connect the EZPRO25 RF chassis to the earth intake in the cabinet where it is to be installed.  Switch off the EZPRO25 RF before inserting/removing any of its modules.   !
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 7 of 21  Initial Release Revision: 00   5. EQUIPMENT DESCRIPTION 5.1 FRONT VIEW   ♦ EZPRO25 RF   1.- RPS P25 (Repeater Power Supply) 2.- RPA P25 (Repeater Power Amplifier) 3.- RTX P25 (Repeater Transmitter) 4.- RRX P25 (Repeater Receiver) 5.- Option RRX2 P25/BSYNC P25 ( Repeater Receiver 2 / EZPRO25 RF Synchronism) 6.- RCPU P25 (Repeater Control Processing Unit) 7 1 2  3  4 5 6
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 8 of 21  Initial Release Revision: 00    5.2 REAR VIEW   ♦ EZPRO25 RF   24232221 20 19 1817 16  15  14  9 10111213  8 25
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 9 of 21  Initial Release Revision: 00  5.3 MODULES  1.  RPS P25 (REPEATER POWER SUPPLY) LEDs to indicate module status.  LED  TYPE  NORMAL STATUS  FUNCTIÓN SUPPLY  Green   On   There are 26.4V at the RPS P25 input 24V or 26.4V  Green   On   There are 26.4V at the RPS P25 output 13.2V  Green   On   There are 13.2V at the RPS P25 output  Power on switch (Ref. 7): ON/OFF switch to connect to and disconnect from the EZPRO25 RF  2.  RPA P25 (REPEATER POWER AMPLIFIER) LEDs to indicate module status.  LED  TYPE  NORMAL STATUS  FUNCTIÓN ON  Green  On  Power supply correct TX POWER  Green   On  Module transmitting  3.  RTX P25 (REPEATER TRANSMITTER) LEDs to indicate module status.  LED  TYPE  NORMAL STATUS  FUNCTIÓN ON  Green   On  Power supply correct REF. ERROR  Red  Off  Failure in the 10 MHz reference INT. ERROR  Red  Off   Internal failure BBSR ERROR  Red  Off   Communication failure with the RCPU P25 module RPA ERROR  Red  Off  RPA P25 failure RPW ERROR Red  Off   Reflected power failure
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 10 of 21  Initial Release Revision: 00
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 11 of 21  Initial Release Revision: 00  4.  RRX P25 (REPEATER RECEIVER) LEDs to indicate module status.   LED  TYPE  NORMAL STATUS FUNCTIÓN ON  Green  On  Power supply correct REF. ERROR  Red  Off   Failure in the 10 MHz reference INT. ERROR  Red  Off   Internal failure BBSR ERROR  Red  Off   Communication failure with the RCPU P25 module  5.  SLOT OPTION: RRX2 / BSYNC (REPEATER RECEIVER 2/ BSR SYNCHRONISM) LEDs to indicate the status of option RRX2.P25   LED  TYPE  NORMAL STATUS FUNCTIÓN ON  Green   On   Power supply correct REF. ERROR  Red  Off  Failure in the 10 MHz reference INT. ERROR  Red  Off  Internal failure BBSR ERROR  Red  Off   Communication failure with the RCPU P25 module  LEDs to indicate the status of option BSYNC P25.   LED  TYPE  NORMAL STATUS FUNCTIÓN ON  Green   On  Power supply correct REF. ERROR  Red  Off   Failure in the 10 MHz reference WARM UP  Red  Off   Oscillator in warming up phase TIME GPS  Green   Flashing  There is NMEA signal from GPS PPS GPS  Green   Flashing  There is PPS signal from GPS TIME LOCAL  Green   Flashing  There is NMEA local signal (without GPS) PPS LOCAL  Green  Flashing  There is PPS local signal (without GPS)  NOTE: this slot is not used in the EZPRO25 RF basic configuration.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 12 of 21  Initial Release Revision: 00  6.  RCPU P25 (REPEATER CONTROL)  LEDs to indicate the module status.  LED  TYPE  NORMAL STATUS FUNCTIÓN ON  Green   On  Power supply correct REF. ERROR  Red  Off  Failure in the 10 MHz reference INT. ERROR  Red  Off   Internal failure BBSR ERROR  Red  Off   BSR bus failure DIV ERROR  Red  Off   Diversity failure CNC ERROR  Red  Off   Communication failure with the CNC AUX  Green   Off   Not used MCCH  Green  Off / On  Main carrier indicator RX  Green   Flickering  APCO P25 information received TX  Green  On   APCO P25 information transmission ETH LINK1  Yellow  On   Link between the local network switch and the RCPU P25 module in Ethernet port 1 ETH LINK2  Yellow  Off   Link between the local network switch and the RCPU P25 module in Ethernet port 1 ETH RX  Green   Flashing   Reception of an Ethernet packet ETH TX  Green   Flashing   Transmission of an Ethernet packet
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 13 of 21  Initial Release Revision: 00   5.4 CABLING AND CONNECTORS  ♦ BSR75   8.- Power supply connector. 9.- Transmission power antenna connector. 10.- SMB RF cables. 11.- Reception antenna connector (receiver chain 1) 12.- Reception antenna connector (receiver chain 2) 13.- Reception antenna connectors for the RRX2 P25 option / antenna connectors for the GPS, depending on the inserted module. 14.- Ethernet B connector. 15.- Ethernet A connector. 16.- SYNC IN2 connector. 17.- SYNC IN1 connector. 18.- SYNC OUT1 connector. 19.- SYNC OUT2 connector. 20.- Maintenance connector for BSR bus.  21.- Connector for VT100 for RCPU P25module maintenance. 22.- Connector for VT100 for RRX2 P25 module maintenance. 23.- Connector for VT100 for RRX1 P25 module maintenance. 24.- Connector for VT100 for RTX P25 module maintenance. 25.- TNC connector for 50Ω load.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 14 of 21  Initial Release Revision: 00   6.  INSTALLATION GUIDE  The following recommendations must be followed closely before starting up the EZPRO25 RF module. 6.1  LOCATION  The EZPRO25 RF have been designed in the standard format of 19” / 3 units high, and so they must be installed in cabinets with this format. The EZPRO25 RF site must be permanent, well-ventilated and without vibrations.  6.2  POWER SUPPLY CONNECTION  DC power supply: check that the power supply source and/or the battery to be used meets the voltage and current requirements necessary to supply the equipment: Nominal voltage: 26.4VDC (range: from 21.6 to 28VDC)  Minimum source current:  10 A   There is a 15 A internal fuse in the RPS module (Ref. 1 of BSR) to protect the equipment from over-voltage. There is a power control circuit in the RPS P25 module in order to avoid an overcurrent condition.  If lead batteries are used, they are to be placed as far from the EZPRO25 RF as possible to prevent corrosion in the repeater due to battery vapours. They should be situated in a well-ventilated place.  Use the power supply connector provided (D013000) to connect the EZPRO25 RF to the power supply source. Use a cable with 2.5 mm2 minimum diameter (or AWG-12). Ensure that the connection is made with the correct polarity.  Ensure that the earth connection is made. Make this connection with a cable of maximum diameter and minimum length. NEVER use a gas or electricity conduit as an earth.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 15 of 21  Initial Release Revision: 00   6.3   ANTENNA CONNECTION   Choose the most adaptable antenna for the installation. The antenna must have an impedance of 50 ohms to the equipment transmission frequency. Install the antenna in accordance with the manufacturer’s instructions.  Use a cable coaxial, avoiding as much as possible large cable lengths. Cable impedance is 50 ohms.  Measure the ROE of the installation. Never accept a ROE greater than 2.  If a duplexer module or a band pass filter is required, adjust them to the work frequency before starting up. 6.4   SWITCHING ON THE EZPRO25 RF   Check the connections between the modules.  Check that the power supply source is connected correctly.  Check that the RF SMB cables are connected correctly (see Rear View diagram Ref. 10).  Check the connections of the antennas in the RPA P25 and RRX modules.  Only in case of the EZPRO25 RF check the 50Ω load is connected to the rear TNC connector in the RPA P25.  Check that the Ethernet connections to the CNC/Gateway are in accordance with the configuration.  Check that the RPS P25 module LED SUPPLY is on.  Activate the power on switch on the RPS P25 module.  Check that the 24V LED and the 13.2V LED on the RPS P25 module or the 26.4V LED and 13.2V LED on the RPS P25 module are on and check that the LEDS ON are switched on for the other modules.  Wait for the EZPRO25 RF to start up.  Check that the mobile equipment is registered in the EZPRO25 RF.  Note: see section 5 for more information on references for the different modules and LEDs.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 16 of 21  Initial Release Revision: 00   7.  CONFIGURATION  A EZPRO25 RF is configured via an NMS (Network Management System). To configure the EZPRO25 RF, consult the NMS manual.   8.   INCIDENTS    The repeater must be repaired by authorized technical personnel only. If a EZPRO25 RF failure occurs, the entire EZPRO25 RF must be replaced. If transmitter module is damaged and there is not an entire EZPRO25 RF available to replace, set RTX P25 and RPA P25 modules previously calibrated jointly. In last case and if is not possible to carry out one of the two previous options, replace one of these two modules and make the gain calibration again.    If an error or alarm occurs in the EZPRO25 RF, this is indicated in the corresponding LED for each one of the modules. The following list shows the possible failures and their solutions.  8.1   ALARMS       Led indication  Status   Failure / Solution SUPPLY OFF  POWER SUPPLY FAILURE. CHECK THAT THE SOURCE AND THE POWER SUPPLY CABLE ARE CORRECTLY CONNECTED. CHECK THE INTERNAL FUSE OF THE RPS P25. CONTACT TECHNICAL SERVICES IF UNSOLVED.  24V or 26.4V  OFF  Power supply failure. Contact Technical services. RPS P25 13.2V  OFF  Power supply failure. Contact Technical services.    RPA P25 ON OFF  POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES.  !
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 17 of 21  Initial Release Revision: 00  TX POWER  OFF  No power transmission in the antenna. Wait for EZPRO25 RF to be started up by the CNC. Check other LED indications. Contact Technical Services if unsolved.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 18 of 21  Initial Release Revision: 00   ON OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES.  REF. ERROR  ON  Failure in the 10MHz reference. Contact Technical services.  INT. ERROR  ON  Internal failure. Contact Technical services.  BBSR ERROR  ON Communication failure with the RCPU P25 module. Check that all the modules are correctly installed. Contact Technical services if still unsolved. RPA P25 ERROR  ON  FAILURE IN THE RPA P25 MODULES. CHECK THAT THE RF SMB CABLES (REF. 10) ARE CORRECTLY CONNECTED. CONTACT TECHNICAL SERVICES I STILL UNSOLVED. RTX P25 RPW ERROR  ON  Reflected power alarm. Check that the antenna is correctly installed. Contact Technical services.    ON OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES. REF. ERROR  ON  Failure in the 10MHz reference. Contact Technical services. INT. ERROR  ON  Internal failure. Contact Technical services.  RRX P25 BBSR ERROR  ON Communication failure with the RCPU P25 module. Check that all the modules are correctly installed. Contact Technical Services if still unsolved.    ON OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES.  REF. ERROR  OFF  Failure in the 10MHz reference. Contact Technical services.  BSYNC P25 TIME GPS  OFF  IF GPS IS ACTIVATED, THERE IS FAILURE IN THE DATA FRAME. CONTACT TECHNICAL SERVICES.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 19 of 21  Initial Release Revision: 00  PPS GPS  OFF  IF GPS IS ACTIVATED, THERE IS FAILURE IN THE PPS SIGNAL OF THE GPS: - CHECK THAT THE STARTING UP PERIOD HAS BEEN EXCEEDED (ABOUT 10 MINUTES AFTER SWITCHING ON) - CHECK THE GPS ANTENNA CONNECTION. - CHECK THE CORRECT POSITIONING OF THE GPS ANTENNA, IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS. CONTACT TECHNICAL SERVICES IF STILL UNSOLVED. TIME LOCAL  OFF  IF GPS IS NOT ACTIVATED, THERE IS FAILURE IN THE LOCAL REFERENCE DATA FRAME. CONTACT TECHNICAL SERVICES. PPS LOCAL  OFF  IF GPS IS NOT ACTIVATED, THERE IS FAILURE IN THE LOCAL PPS SIGNAL. CONTACT TECHNICAL SERVICES.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 20 of 21  Initial Release Revision: 00   ON OFF  INTERNAL POWER SUPPLY FAILURE. CONTACT TECHNICAL SERVICES. REF ERROR  ON  Failure in the 10MHz reference. Check that the BSYNC P25 module is installed or that the SYNC IN cable is correctly connected. Contact Technical services if still unsolved. INT ERROR  ON  Internal failure. Contact Technical Services. BBSR ERROR  ON  Communication failure by the EZPRO25 RF bus. Check that all the modules are correctly installed. Contact Technical services if still unsolved. DIV ERROR  ON  Error in diversity: occurs when the difference in received power between received paths exceeds a level (20 dBs by default) for a consecutive number of receptions. These receptions on the received paths which do not have sufficient power are not counted. This alarm does not disappear until there are no receptions with the sufficient power, and until the difference of received power between received paths does not exceed the level previously mentioned. Check diversity configuration in the CNC.  Check that the reception antennas are correctly installed. Contact Technical services if still unsolved. CNC ERROR  ON  Communication failure with the CNC. Check the Ethernet connections.  Check that the CNC is working correctly. Contact Technical Services if still unsolved. RX Continuous ON  Interference detection. Check the installation. Check that the work frequencies are correct. ETH LINK1  OFF  Failure in Ethernet link 1. Check Ethernet connection 1 and the Switch A. ETH LINK2  OFF  Failure in Ethernet link 2. Check Ethernet connection 2 and the Switch B. ETH RX  OFF  Packets are not received by Ethernet. Check the Ethernet connections. RCPU P25 ETH TX  OFF  Packets are not sent by Ethernet. Check the Ethernet connections.
   Code: Installation Guide EZPRO25 RF.do INSTALLATION GUIDE  Date: 12/18/2007 Page: 21 of 21  Initial Release Revision: 00     8.2 ALARMS WITHOUT STATUS LEDS  8.2.1 Interference at the bsr. This alarm is monitored in APCO P25 Network Management System (NMS). See “APCO P25 Event List” in NMS help. An interference in the EZPRO25 RF is activated when a high number of invalid consecutive receptions occurs at a EZPRO25 RF. An invalid reception is that which has a signal level higher than the minimum level of reception of the carrier, but it is not recognised as a APCO P25 signal. This alarm is switched off upon correct reception.