IR TEC HS150900 Occupancy Sensor User Manual IM EN LMS 509

IR-TEC International Ltd. Occupancy Sensor IM EN LMS 509

User Manual

Download: IR TEC HS150900 Occupancy Sensor User Manual IM EN LMS 509
Mirror Download [FCC.gov]IR TEC HS150900 Occupancy Sensor User Manual IM EN LMS 509
Document ID3496452
Application ID3oKYatsPU/m2/mj8DLgA/A==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.1kB (163798 bits)
Date Submitted2017-08-04 00:00:00
Date Available2017-08-04 00:00:00
Creation Date2017-07-19 08:46:48
Producing SoftwareAdobe PDF library 10.01
Document Lastmod2017-07-19 17:22:20
Document TitleIM-EN_LMS-509
Document CreatorAdobe Illustrator CS6 (Windows)

OVERVIEW
LMS-509 series
Line Voltage Occupancy Sensor
INSTALLATION INSTRUCTIONS
APPLICATION NOTES
The LMS-509 series member of the TRANS family is a line
voltage occupancy sensor designed for all-purposes energy
efficient lighting control. This occupancy sensor employs an
advanced High Frequency Doppler (HFD) sensing technology
to provide superior sensing performance of minor motions,
such as typing, writing, or reading. The HFD technology is
operating with high frequency radio waves which are capable of
detecting the occupant's presence and movements without
requiring unobstructed line-of-sight like PIR sensor.
Avoid placing the sensor in an area surrounded with
metallic wall which may block or absorb the radio
wave. If possible, place the sensor to the opening
as close as possible.
Fluorescent light may cause interference to the HFD
sensor operation, and result in lighting permanent
on. If possible, avoid placing the HFD sensor within
1m (3ft.) of fluorescent light.
The Accu-Set digitalized potentiometers make the sensor
setting easier, faster and more accurate than the conventional
analog ones. 4 levels of sensitivity can be selected via DIP
switch setting to provide different coverage. An exclusive Hybrid
Switching technology makes LMS-509 series perfect to control
the lighting with exceptionally high inrush current (HIC) while
switching on, such as multiple LED or CFL lightings connected
in parallel. The sensor comes with ambient light sensor (ALS) to
inhibit switching on the light if the ambient light level is higher
than the threshold set. Like all sensors in the TRANS family, the
LMS-509 series is also available in various mounting options.
WARNING & CAUTION
Risk of Electric Shock - Disconnect power supply before
servicing.
Open Type Photoelectric Switches.
AVERTISSEMENT & PRUDENCE
Risque de choc électrique -Débranchez l'alimentation avant
l'entretien.
Ouvrir Type commutateurs optoélectroniques.
www.irtec.com
Avoid sensor placement facing doors, corridors or
exits as HFD sensor may detect the traffics at
adjacent area.
HFD sensors are best for use in areas with partitions
and high dividers, or high level of minor motion
activities.
Federal Communication Commission Interference Statement
The HFD sensor is more sensitive to the movements
“toward” than “across” the sensor, so ensure to
place the sensor at the position “toward” the
movements of occupant.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
DETECTION PATTERN
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
P/N: 058-50904-004
Printed in Taiwan
This product may be covered by one or more U.S. patents or patent applications.
Please visit www.irtec.com for more information.
Mounting Height
Coverage*
*Sensitivity 100%
3 m (10 ft)
180 m2 (2,000 ft2)
(m)
Minor motion
Major motion
6 m (20 ft)
100 m2 (1,200 ft2)
(ft)
10
30
20
10
20
20
9 (m)
30 (ft)
OPERATION
SENSOR SETTINGS
Sensitivity
The LMS-509S is an occupancy sensor designed to provide
switched line voltage power to switch on the controlled
lighting when it detects the presence of occupant. The
sensor will automatically turn off the light after the area is no
longer occupied for a period of time. An ambient light
sensor (ALS) is built-in to inhibit switching on the light if
daylighting level is higher than the threshold set.
The LMS-509 provides 7 different light-Off delay time and
daylight threshold settings via 2 potentiometers marked T
and L respectively. 4 levels of sensitivity can be set via
combination DIP switch #1 and #2.
The sensitivity and detection pattern of HFD sensor
may vary with the furniture placement, partition layout,
wall material, and shape of the space. For example, the
detection pattern will become long rectangular if sensor is
placed in a long corridor. 4 levels of sensitivity can be set
via combinations of DIP switch #1 and #2.
To change the sensor
setting, rotate the front
cover counter-clockwise
to remove. Replace the
front cover after the
setting complete.
Click!
WIRING DIAGRAM
The LMS-509 series can be mounted with a junction box
into the ceiling, internally integrated or externally attached
to a fixture to control the lighting with specific mounting
bracket. Please refer to the mounting instructions
separately attached for details of mounting options
available.
LMS-509
Neutral
Load
White
Red
LMS-509
White
LMS-509
Black
White
White
Red
Black
(10 minutes)
(Factory set)
ON
(Factory set)
(ALS disabled)
Line
B. Multiple sensors control
SW1 & 2 (100% Sensitivity)
SW3 & 4 (No Function)
Line
25%
ON
ON
ON
ON
DIP switch
setting
ON-ON
ON-OFF
OFF-ON
OFF-OFF
Power supply
120/230/277VAC
Maximum Load
@ -40°C~55°C
(-40°F~131°F)
Incandescent/Halogen – 800/1200W(VA)@120/277V
Fluorescent Ballast/CFL – 800/1200W(VA)@120/277V
Ballast Electronic (LED) – 540/1200VA@120/277V
Incandescent/Halogen – 500/750W(VA)@120/277V
Maximum Load
@ 55°C~70°C
(131°F~158°F)
Fluorescent Ballast/CFL – 500/750W(VA)@120/277V
HFD sensitivity
25/50/75/100% selectable via DIP switch setting
Ballast Electronic (LED) – 500/750VA@120/277V
Load switching
Zero-cross Hybrid-Switching
T (min.)
T*
1’
3’
5’
10’
20’
30’
10
15
20
25
60 24H
HIC protection
Max. 80A for 16.7msec.
Detection range
Up to 180 sq. m @ 3 m (2,000 sq. ft. @ 10 ft)
Mounting height
2.4 ~ 6 m (8 ~ 20 ft)
Ambient light level
7 level Accu-Set digital potentiometer
Delay time setting
T/1'/3'/5'/10'/20'/30' , T=10 sec. for testing
Op. humidity
Max. 95% RH
Op. temperature
-40°C~70°C (-40°F~158°F)
Dimensions
Ø60 x H42mm (2.36"x H1.65")
Factory Set
Load
50%
Position
L (lux)
Neutral
75%
SPECIFICATIONS
White
Red
Black
100%
NOTE: DIP switch #3 and #4 are not functional for LMS-509S.
A. Single sensor control
White
Sensitivity
*T=10 seconds shorten delay for testing convenience. The
sensor will automatically resume to the factory default delay
setting after 10 minutes, if the potentiometer has not been
adjusted to other position.
T - Delay Time
The potentiometer T sets the period of delay time that sensor
will turn off the connected lights after the area is vacated.
L - Ambient Light Level
The potentiometer L sets the ambient light level that the
sensor will activate occupancy sensing control.
www.irtec.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Format                          : application/pdf
Title                           : IM-EN_LMS-509
Creator Tool                    : Adobe Illustrator CS6 (Windows)
Create Date                     : 2017:07:19 08:46:48+09:00
Modify Date                     : 2017:07:19 17:22:20+08:00
Metadata Date                   : 2017:07:19 17:22:20+08:00
Thumbnail Width                 : 256
Thumbnail Height                : 220
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 19598 bytes, use -b option to extract)
Document ID                     : xmp.did:02CA78BD1B6CE7118294D2B9D1AF82C8
Instance ID                     : uuid:ea5c04b7-6a8d-4558-b5d7-ba8a7e3ed35d
Original Document ID            : uuid:204986159B0AE111BDC19448B1A00566
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:937b2fec-2b97-4bbc-a038-155fa535a180
Derived From Document ID        : xmp.did:FC1B17542856E7118F969CC94CA2BA4A
Derived From Original Document ID: uuid:204986159B0AE111BDC19448B1A00566
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:690747482FECE111A2868A1CFD8DCAE5, xmp.iid:02CA78BD1B6CE7118294D2B9D1AF82C8
History When                    : 2012:08:22 15:59:21+08:00, 2017:07:19 08:46:45+08:00
History Software Agent          : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows)
History Changed                 : /, /
Producer                        : Adobe PDF library 10.01
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : False
Max Page Size W                 : 29.699996
Max Page Size H                 : 20.999993
Max Page Size Unit              : Centimeters
Font Name                       : ArialMT, Swiss721BT-Roman, Swiss721BT-Bold
Font Family                     : Arial, Swis721 BT, Swis721 BT
Font Face                       : Regular, Roman, Bold
Font Type                       : Open Type, Open Type, Open Type
Font Version                    : Version 6.90, Version 1.01 emb4-OT, Version 1.01 emb4-OT
Font Composite                  : False, False, False
Font File Name                  : arial.ttf, tt0003m_.ttf, tt0005m_.ttf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Groups Group Name        : 預設色票群組
Swatch Groups Group Type        : 0
Swatch Groups Colorants Swatch Name: New Color Swatch 6
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Cyan    : 10.196100
Swatch Groups Colorants Magenta : 0.000000
Swatch Groups Colorants Yellow  : 82.745102
Swatch Groups Colorants Black   : 0.000000
Page Count                      : 2
Creator                         : Adobe Illustrator CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NRIHS150900

Navigation menu