IR TEC HS150900 Occupancy Sensor User Manual IM EN LMS 509
IR-TEC International Ltd. Occupancy Sensor IM EN LMS 509
IR TEC >
User Manual
OVERVIEW LMS-509 series Line Voltage Occupancy Sensor INSTALLATION INSTRUCTIONS APPLICATION NOTES The LMS-509 series member of the TRANS family is a line voltage occupancy sensor designed for all-purposes energy efficient lighting control. This occupancy sensor employs an advanced High Frequency Doppler (HFD) sensing technology to provide superior sensing performance of minor motions, such as typing, writing, or reading. The HFD technology is operating with high frequency radio waves which are capable of detecting the occupant's presence and movements without requiring unobstructed line-of-sight like PIR sensor. Avoid placing the sensor in an area surrounded with metallic wall which may block or absorb the radio wave. If possible, place the sensor to the opening as close as possible. Fluorescent light may cause interference to the HFD sensor operation, and result in lighting permanent on. If possible, avoid placing the HFD sensor within 1m (3ft.) of fluorescent light. The Accu-Set digitalized potentiometers make the sensor setting easier, faster and more accurate than the conventional analog ones. 4 levels of sensitivity can be selected via DIP switch setting to provide different coverage. An exclusive Hybrid Switching technology makes LMS-509 series perfect to control the lighting with exceptionally high inrush current (HIC) while switching on, such as multiple LED or CFL lightings connected in parallel. The sensor comes with ambient light sensor (ALS) to inhibit switching on the light if the ambient light level is higher than the threshold set. Like all sensors in the TRANS family, the LMS-509 series is also available in various mounting options. WARNING & CAUTION Risk of Electric Shock - Disconnect power supply before servicing. Open Type Photoelectric Switches. AVERTISSEMENT & PRUDENCE Risque de choc électrique -Débranchez l'alimentation avant l'entretien. Ouvrir Type commutateurs optoélectroniques. www.irtec.com Avoid sensor placement facing doors, corridors or exits as HFD sensor may detect the traffics at adjacent area. HFD sensors are best for use in areas with partitions and high dividers, or high level of minor motion activities. Federal Communication Commission Interference Statement The HFD sensor is more sensitive to the movements “toward” than “across” the sensor, so ensure to place the sensor at the position “toward” the movements of occupant. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. DETECTION PATTERN This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. P/N: 058-50904-004 Printed in Taiwan This product may be covered by one or more U.S. patents or patent applications. Please visit www.irtec.com for more information. Mounting Height Coverage* *Sensitivity 100% 3 m (10 ft) 180 m2 (2,000 ft2) (m) Minor motion Major motion 6 m (20 ft) 100 m2 (1,200 ft2) (ft) 10 30 20 10 20 20 9 (m) 30 (ft) OPERATION SENSOR SETTINGS Sensitivity The LMS-509S is an occupancy sensor designed to provide switched line voltage power to switch on the controlled lighting when it detects the presence of occupant. The sensor will automatically turn off the light after the area is no longer occupied for a period of time. An ambient light sensor (ALS) is built-in to inhibit switching on the light if daylighting level is higher than the threshold set. The LMS-509 provides 7 different light-Off delay time and daylight threshold settings via 2 potentiometers marked T and L respectively. 4 levels of sensitivity can be set via combination DIP switch #1 and #2. The sensitivity and detection pattern of HFD sensor may vary with the furniture placement, partition layout, wall material, and shape of the space. For example, the detection pattern will become long rectangular if sensor is placed in a long corridor. 4 levels of sensitivity can be set via combinations of DIP switch #1 and #2. To change the sensor setting, rotate the front cover counter-clockwise to remove. Replace the front cover after the setting complete. Click! WIRING DIAGRAM The LMS-509 series can be mounted with a junction box into the ceiling, internally integrated or externally attached to a fixture to control the lighting with specific mounting bracket. Please refer to the mounting instructions separately attached for details of mounting options available. LMS-509 Neutral Load White Red LMS-509 White LMS-509 Black White White Red Black (10 minutes) (Factory set) ON (Factory set) (ALS disabled) Line B. Multiple sensors control SW1 & 2 (100% Sensitivity) SW3 & 4 (No Function) Line 25% ON ON ON ON DIP switch setting ON-ON ON-OFF OFF-ON OFF-OFF Power supply 120/230/277VAC Maximum Load @ -40°C~55°C (-40°F~131°F) Incandescent/Halogen – 800/1200W(VA)@120/277V Fluorescent Ballast/CFL – 800/1200W(VA)@120/277V Ballast Electronic (LED) – 540/1200VA@120/277V Incandescent/Halogen – 500/750W(VA)@120/277V Maximum Load @ 55°C~70°C (131°F~158°F) Fluorescent Ballast/CFL – 500/750W(VA)@120/277V HFD sensitivity 25/50/75/100% selectable via DIP switch setting Ballast Electronic (LED) – 500/750VA@120/277V Load switching Zero-cross Hybrid-Switching T (min.) T* 1’ 3’ 5’ 10’ 20’ 30’ 10 15 20 25 60 24H HIC protection Max. 80A for 16.7msec. Detection range Up to 180 sq. m @ 3 m (2,000 sq. ft. @ 10 ft) Mounting height 2.4 ~ 6 m (8 ~ 20 ft) Ambient light level 7 level Accu-Set digital potentiometer Delay time setting T/1'/3'/5'/10'/20'/30' , T=10 sec. for testing Op. humidity Max. 95% RH Op. temperature -40°C~70°C (-40°F~158°F) Dimensions Ø60 x H42mm (2.36"x H1.65") Factory Set Load 50% Position L (lux) Neutral 75% SPECIFICATIONS White Red Black 100% NOTE: DIP switch #3 and #4 are not functional for LMS-509S. A. Single sensor control White Sensitivity *T=10 seconds shorten delay for testing convenience. The sensor will automatically resume to the factory default delay setting after 10 minutes, if the potentiometer has not been adjusted to other position. T - Delay Time The potentiometer T sets the period of delay time that sensor will turn off the connected lights after the area is vacated. L - Ambient Light Level The potentiometer L sets the ambient light level that the sensor will activate occupancy sensing control. www.irtec.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : IM-EN_LMS-509 Creator Tool : Adobe Illustrator CS6 (Windows) Create Date : 2017:07:19 08:46:48+09:00 Modify Date : 2017:07:19 17:22:20+08:00 Metadata Date : 2017:07:19 17:22:20+08:00 Thumbnail Width : 256 Thumbnail Height : 220 Thumbnail Format : JPEG Thumbnail Image : (Binary data 19598 bytes, use -b option to extract) Document ID : xmp.did:02CA78BD1B6CE7118294D2B9D1AF82C8 Instance ID : uuid:ea5c04b7-6a8d-4558-b5d7-ba8a7e3ed35d Original Document ID : uuid:204986159B0AE111BDC19448B1A00566 Rendition Class : proof:pdf Derived From Instance ID : uuid:937b2fec-2b97-4bbc-a038-155fa535a180 Derived From Document ID : xmp.did:FC1B17542856E7118F969CC94CA2BA4A Derived From Original Document ID: uuid:204986159B0AE111BDC19448B1A00566 Derived From Rendition Class : proof:pdf History Action : saved, saved History Instance ID : xmp.iid:690747482FECE111A2868A1CFD8DCAE5, xmp.iid:02CA78BD1B6CE7118294D2B9D1AF82C8 History When : 2012:08:22 15:59:21+08:00, 2017:07:19 08:46:45+08:00 History Software Agent : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Windows) History Changed : /, / Producer : Adobe PDF library 10.01 N Pages : 1 Has Visible Transparency : True Has Visible Overprint : False Max Page Size W : 29.699996 Max Page Size H : 20.999993 Max Page Size Unit : Centimeters Font Name : ArialMT, Swiss721BT-Roman, Swiss721BT-Bold Font Family : Arial, Swis721 BT, Swis721 BT Font Face : Regular, Roman, Bold Font Type : Open Type, Open Type, Open Type Font Version : Version 6.90, Version 1.01 emb4-OT, Version 1.01 emb4-OT Font Composite : False, False, False Font File Name : arial.ttf, tt0003m_.ttf, tt0005m_.ttf Plate Names : Cyan, Magenta, Yellow, Black Swatch Groups Group Name : 預設色票群組 Swatch Groups Group Type : 0 Swatch Groups Colorants Swatch Name: New Color Swatch 6 Swatch Groups Colorants Type : PROCESS Swatch Groups Colorants Tint : 100.000000 Swatch Groups Colorants Mode : CMYK Swatch Groups Colorants Cyan : 10.196100 Swatch Groups Colorants Magenta : 0.000000 Swatch Groups Colorants Yellow : 82.745102 Swatch Groups Colorants Black : 0.000000 Page Count : 2 Creator : Adobe Illustrator CS6 (Windows)EXIF Metadata provided by EXIF.tools