Ibis Networks 301 Single InteliSocket User Manual DataSheet IS 301x
Ibis Networks Inc. Single InteliSocket DataSheet IS 301x
User Manual
IS-301 Single InteliSocket⢠FEATURES ⢠⢠⢠⢠⢠⢠120V 15A UL Certification ZigBee Pro 17dBm RF Power Surge Protected RoHS Compliant DESCRIPTION The IS-301 is a smart socket which meters plug load energy usage and provides device on/off capability. It works with other InteliSocketsTM to form a secure wireless mesh network for control and reporting of data. Each network is anchored by an InteliGatewayTM base station providing connectivity to the InteliNetworkTM, a cloud-based data collection and analysis application. PERFORMANCE Parameter Input Voltage (RMS) Input Frequency Output Current (RMS) Output Power Power Consumption Reporting Interval Accuracy (Energy) Accuracy (Voltage) Accuracy (Interval) Resolution RF Range RF Transmit Power Sockets per Network ZigBee Channels ZigBee Hive Size * Channel 26 limited to 3dBm Ibis Networks 02/24/16 Symbol VIN Min 108 Typ 120 60 IOUT POUT Max 132 15 1800 15 255 0.5 50 17 Units Hz ms W-s dBm 120 26* 0x3FFF 11 0x3000 3.0 x 1.5 x 1.4 ¡ 841 Bishop Street Suite 1601 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com inches IS-301 Single InteliSocket⢠COMPLIANCE Agency UL916 â Energy Management Equipment ZigBee Profile (Plover) FCC File 0x114B ENVIRONMENTAL Parameter Operating Temperature Storage Temperature Relative Humidity Symbol TO TS RH Min -40 Typ 25 Max 40 100 95 Units InteliSockets are for indoor use only. PROTOCOL InteliSockets use Ibisâ custom Plover profile for commands, acknowledgements, and reporting of data. DATA InteliSockets report data typically every 15 seconds. Each report packet is comprised of socket type, ZigBee channel, ZigBee hive (PANID), interval (seconds), voltage (RMS), frequency (Hz), energy (watt-seconds), and power factor (fraction). From these data we can calculate instantaneous power (watts) and current (amps). ¡ The InteliGateway appends additional information (IP, timestamp, location, etc.) before uploading to the InteliNetwork. This allows any socket in the world to be located and addressed individually. Ibis Networks 02/24/16 ¡ 841 Bishop Street Suite 1601 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com IS-301 Single InteliSocket⢠PUSHBUTTON The illuminated pushbutton provides addition control features. First and foremost, it is a manual override for turning the outlet on (green) and off (red). If pressed and held for at least three seconds it causes a reboot of the socket. If held in for ten seconds (two reboots) it reverts back into factory mode settings. This is a useful feature for maintenance purposes or when a socket gets moved from one location to another. A blinking backlight indicates the socket has not associated with a mesh network yet. FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ⢠⢠⢠⢠Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the userâs authority to operate this equipment. To satisfy RF exposure requirements, this device and its antenna must operate with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Ibis Networks 02/24/16 ¡ 841 Bishop Street Suite 1601 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 3 Producer : GPL Ghostscript 8.15 Create Date : 2016:03:10 09:25:25 Modify Date : 2016:03:10 09:25:25 Title : Microsoft Word - DataSheet-IS-301.docx Creator : PScript5.dll Version 5.2.2 Author : ibisadminEXIF Metadata provided by EXIF.tools