Ibis Networks 302 Dual InteliSocket User Manual DataSheet IS 302x
Ibis Networks Inc. Dual InteliSocket DataSheet IS 302x
Users Manual
IS-302 Dual InteliSocket⢠FEATURES ⢠120V 15A ⢠ZigBee Pro ⢠13 dBm RF Power ⢠Surge Protected ⢠RoHS Compliant ⢠Title 24 Part 6 Compliant DESCRIPTION The IS-302 is a dual smart socket which meters plug load energy usage and provides device on/off capability. It works with other InteliSocketsTM to form a secure wireless mesh network for control and reporting of data. Each network is anchored by an InteliGatewayTM base station providing connectivity to the InteliNetworkTM, a cloud-based data collection and analysis application. PERFORMANCE Parameter Input Voltage (RMS) Input Frequency Output Current (RMS) Output Power Power Consumption Reporting Interval Accuracy (Energy) Accuracy (Voltage) Accuracy (Interval) RF Range Resolution RF Transmit Power Sockets per Network ZigBee Channels ZigBee Hive Size * Channel 26 limited to 3dBm Ibis Networks 02/24/16 Symbol VIN Min 108 Typ 120 60 IOUT POUT Max 132 15 1800 15 255 0.5 50 13 11 0x3000 4.5 x 2.75 x 1.4 Units Hz ms W-s dBm 120 26* 0x3FFF ¡ 841 Bishop Street Suite 1601 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com inches IS-302 Dual InteliSocket⢠COMPLIANCE Agency UL916 â Energy Management Equipment ZigBee Profile (Plover) FCC File 0x114B ENVIRONMENTAL Parameter Operating Temperature Storage Temperature Relative Humidity Symbol TO TS RH Min -40 Typ 25 Max 40 100 95 Units InteliSockets are for indoor use only. PROTOCOL InteliSockets use Ibisâ custom Plover profile for commands, acknowledgements, and reporting of data. DATA InteliSockets report data typically every 15 seconds. Each report packet is comprised of socket type, ZigBee channel, ZigBee hive (PANID), interval (seconds), voltage (RMS), frequency (Hz), energy (watt-seconds), and power factor (fraction). From these data we can calculate instantaneous power (watts) and current (amps). ¡ The InteliGateway appends additional information (IP, timestamp, location, etc.) before uploading to the InteliNetwork. This allows any socket in the world to be located and addressed individually. Ibis Networks 02/24/16 ¡ 841 Bishop Street Suite 1601 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com IS-302 Dual InteliSocket⢠PUSHBUTTON The illuminated pushbutton provides addition control features. First and foremost, it is a manual override for turning the outlet on (green) and off (red). If pressed and held for at least three seconds it causes a reboot of the socket. If held in for ten seconds (two reboots) it reverts back into factory mode settings. This is a useful feature for maintenance purposes or when a socket gets moved from one location to another. A blinking backlight indicates the socket has not associated with a mesh network yet. DUAL OUTLETS The outlets on the IS-302 are metered separately, although only one of them can be turned off. The âalways onâ outlet is meant to be used for monitoring a device such as a computer or lamp, which provides an indication of a userâs presence, and can be used as an event trigger. For example, when the computer goes into sleep mode, it flags the InteliNetwork software to shut down the âcontrolledâ outlet. Such behavioral control can potentially lead to greater savings than fixed time schedules. In typical use, a power strip is plugged into the âcontrolledâ outlet, providing combined control and monitoring of a number of devices. Thus, the IS-302 offers a unique, low cost solution for the âdesktopâ or âcubicleâ. Tracking is organized by person, not device. TITLE 24 The IS-302 is Title24 compliant. FCC This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ⢠⢠⢠Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the Ibis Networks 02/24/16 ¡ 841 Bishop Street Suite 1601 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com IS-302 Dual InteliSocket⢠⢠receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the userâs authority to operate this equipment. To satisfy RF exposure requirements, this device and its antenna must operate with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Ibis Networks 02/24/16 ¡ 841 Bishop Street Suite 1601 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : ibisadmin Create Date : 2016:03:10 08:56:36Z Modify Date : 2016:07:13 16:10:44-07:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : ibisadmin Title : Microsoft Word - DataSheet-IS-302.docx Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2016:07:13 16:10:44-07:00 Producer : GPL Ghostscript 8.15 Document ID : uuid:a4eef24b-8f8e-440a-a2e8-65b4a3f3cef1 Instance ID : uuid:b18d5496-abbc-436b-bae4-cbff410555c9 Page Count : 4EXIF Metadata provided by EXIF.tools