Ideal Lighting CREE Lighting SWG SmartCast Wireless Gateway User Manual

Cree, Inc SmartCast Wireless Gateway

User manual

INSTALLATION INSTRUCTIONS
CSC-GW-CWC
SmartCast® Wireless Gateway
Includes: T-Bar Mounting
LPN00584X0001A0_A
1 of 2
1
Insert Electrical
Wire
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant l’installation.
2. Must be installed in accordance with the NEC or your local electrical
code. If you are not familiar with these codes and requirements, consult a
qualied electrician.
Ce produit doit être installé conformément à NEC ou votre code électrique
local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez
contacter un électricien qualié.
3. Indoor use only and Suitable for Damp Locations.
Pour usage interieur seulement et convient aux emplacements humides.
4. This equipment shall be installed and operated with a minimum distance 20cm
between the radiator and your body.
L’équipement doit etre installe d’une facon qu’une distance minimum de 20cm
soit maintenue entre l’emetteur et toute partie du corps.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
Suitable for use in other Environmental Air Space
(Plenums) in accordance with section 300.22,(C) of the
National Electrical Code, and Sections 2-128, 12-010(3)
and 12-100 of teh Cnadian Electrical Code, Part 1 CSA
C22.1
Peut être utilisé dans de gaines transportant de
l’air traité, conformément à la section 300.22,(C) du
National Electrical Eode et aux articles 2-128, 12-010(3)
ET 12-100 du Code Candian de l’électricité Premiére
partie, CSA C22.1.
Plenum rated cables need to be used when the SWG is
installed in a plenum.
SWG needs to connected to PoE networks without
routing to outside plant connections.
NOTE:
Not for use with equipment that requires constant power or equipment that
presents a hazard if automatically energized. Devices requiring soft shutdown
(such as computers) or other power related requirements (such as projectors,
DVRs or Clocks) may not be compatible.
INSTALLATION
STEP 1:
Insert electrical wire into the back of the SWG unit. See Figure 1.
NOTE: Plenum rated cables need to be used when the SWG is installed
in a plenum.
STEP 2:
Insert the T-Bar clip into the back of the SWG unit using provided screw
as shown in Figure 2.
STEP 3:
Attach to T-Bar ceiling by spreading the clip arms apart to appropriate
width and snap the clip onto the T-Bar. See Figure 2.
2
T-Bar Clip
Arms
T-Bar Clip
Screw
Back of the SWG Unit
LPN00584X0001A0_A
2 of 2
www.cree.com/lighting
© 2018 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See
http://ligthing.cree.com/warranty for warranty and specifications. Cree® and SmartCast® are registered
trademarks, and the Cree logo is a trademark of Cree, Inc.
CONNECTING TO YOUR SMARTCAST® NETWORK
STEP 1:
Using a Cat 5 or Cat 6 cable, connect the SmartCast Wireless Gateway
to a 802.3af compatible PoE switch via the ethernet connector (RJ45)
found on the backside of the device.
STEP 2:
After connecting your device to a PoE switch, the AMBER and GREEN
LEDs located on the connector will illuminate, indicating the device is
powered on and successfully communicating to the PoE switch.
NOTE: If a PoE DC injector is used, the LEDs may not illuminate until
the network has been established.
Please refer to the SmartCast Link Configuration Guide for further
information on how to configure your device in your SmartCast network.
TROUBLESHOOTING:
If LEDs do not illuminate:
1. Check that the network cable is connected to a 802.3af
compatible PoE switch and the power to the PoE switch is
turned on.
2. Check that the network cable is fully seated in the connector on
the back side of the SmartCast Wireless Gateway such that the
locking feature is fully engaged.
3. Please refer to the SmartCast Link Configuration Guide for
further troubleshooting information.
FCC NOTICE
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the device.
This device has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the device is operated in a commercial environment.
This device generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of
this device in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his
own expense.
In addition, this device complies with ICES-005 of the Industry Canada
(IC) Regulations.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation
of the device. In addition, this device complies with ICES-005 of the
Industry Canada (IC) Regulations.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas
produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.

Navigation menu