Identec Solutions ILR-IQ350LM UHF Tag User Manual i Q350L M Hardware Manual

Identec Solutions AG UHF Tag i Q350L M Hardware Manual

User Manual

Download: Identec Solutions ILR-IQ350LM UHF Tag User Manual i Q350L M   Hardware Manual
Mirror Download [FCC.gov]Identec Solutions ILR-IQ350LM UHF Tag User Manual i Q350L M   Hardware Manual
Document ID1253178
Application IDw+0UN9IVNVcSVh3cq3U2ZQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.66kB (358268 bits)
Date Submitted2010-03-17 00:00:00
Date Available2010-03-17 00:00:00
Creation Date2009-12-16 12:17:27
Producing SoftwareAFPL Ghostscript 8.51
Document Lastmod2010-01-18 11:16:31
Document Titlei-Q350L M - Hardware Manual
Document CreatorFreePDF 4.02 - http://shbox.de
Document Author: Administrator

i-Q350L M, Microtag Manual
Microtag Manual
Proprietary Notice
This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or
disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS.
Disclaimer and Limitation of Liability
IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents provide the
information contained in this Manual on an “as-is” basis and do not make any express or implied warranties or
representations with respect to such information including, without limitation, warranties as to noninfringement, reliability, fitness for a particular purpose, usefulness, completeness, accuracy or up-to-dateness.
IDENTEC SOLUTIONS shall not in any circumstances be liable to any person for any special, incidental, indirect
or consequential damages, including without limitation, damages resulting from use of or reliance on
information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in
advance of the possibility of such damages.
Trademarks
“IDENTEC SOLUTIONS”, “Intelligent Long Range”, “ILR” and the stylized “i” are registered trademarks and
“i-Q”, “i-D”, “i-B”, “i-CARD”, “i-PORT”, “i-LINKS”, “Solutions. It’s in our name.”, “Smarten up your assets” are
trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG.
Copyright Notice
Copyright © 2007 IDENTEC SOLUTIONS. All rights reserved.
No part of this document may be reproduced or transmitted in any form by any means, photographic,
electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior
written permission of IDENTEC SOLUTIONS.
Issue 0 / December 2009
– 16. December 2009 –
IDENTEC SOLUTIONS AG,
Millenium Park 2, 6890 Lustenau, Austria
Phone: +43 5577 87387- 0, Fax: +43 5577 87387-15
E-Mail: info@identecsolutions.at
www.identecsolutions.com
Subject to alteration without prior notice.
© Copyright IDENTEC SOLUTIONS 2009
Page 2 of 11
i-Q350L M
Radio Frequency Compliance Statement
IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices:
MODELS:
Region/Country
EUROPE
USA
Canada
i-Q350L M
Organization
EC
FCC
Industry Canada
Marking
CE
FFC ID 004-ILR-IQ350LM
IC: 3538A-IQ350LM
The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by
IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC
SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
European Notification according R&TTE Directive
This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the
following standards: ETSI EN 300 220, ETSI EN 301 489, EN 60950
USA Notification
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by
IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC
SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Page 3 of 11
Microtag Manual
Contents
INTRODUCTION............................................................................................................5
1.1
1.2
1.3
1.4
1.5
1.6
PREPARATIONS ....................................................................................................................5
RECOMMENDED PROCEDURE ....................................................................................................5
SCOPE OF THIS DOCUMENT .....................................................................................................5
RESPONSIBILITY ...................................................................................................................5
ASSOCIATED DOCUMENTS .......................................................................................................5
SCOPE OF DELIVERY—VISUAL INSPECTION .................................................................................5
SAFETY PRECAUTIONS .................................................................................................6
INITIAL OPERATION ....................................................................................................8
3.1
3.2
MAINTENANCE..............................................................................................................9
4.1
4.2
4.3
CONFIGURATION OF THE TAG ..................................................................................................8
TAG HANDLING ....................................................................................................................8
GENERAL ............................................................................................................................9
PRECAUTIONARY MAINTENANCE ...............................................................................................9
RETURNS ............................................................................................................................9
TECHNICAL DATA .......................................................................................................10
Page 4 of 11
i-Q350L M
1.1
Introduction
Preparations
This installation manual must be read carefully prior to starting the installation. The described installation
works assume that installation materials like cable, antenna and tag holder etc are available.
1.2
Recommended Procedure
1.
2.
3.
4.
5.
Check the Scope of Delivery according to the Bill of Delivery
Read this manual completely
Do the initial operation for every single tag
Mount the tags
An additional performance check of the tags and a system test can now be done
1.3
Scope of this Document
This document is the user’s manual of the model i-Q350L M.
This document is intended only for mechanical installation rsp. everyday use.
1.4
Responsibility
IDENTEC SOLUTIONS is not responsible for any errors occurring in this document.
1.5
•
1.6
Associated Documents
i-Q350L M — ILR350 Microtag Datasheet
Scope of Delivery—Visual Inspection
Check delivery whether it is complete and for any damages. If the delivery is not complete or damaged
immediately inform the carrier. The dispatch and service organization of IDENTEC SOLUTIONS should also be
informed to facilitate the repair or exchange of the system.
Page 5 of 11
Microtag Manual
Safety Precautions
Important Safety Note
The devices described in this manual is for exclusive operation by trained employees. Only qualified personnel
that know the potential dangers involved should perform the installation, settings, maintenance and repair of
the units used.
Operational Safety
The correct and safe use of these systems assumes that operating and service personnel follow the safety
measures described in the manual alongside the generally acceptable safety procedures.
If there is a possibility that safe operation cannot be guaranteed the system must be switched off and secured
against accidental use. Then the service unit responsible must be informed.
Do not open the housing
There is no need to open the housing. There are no user serviceable parts inside. Set-up and configuration
during initial operation is done wireless with the built-in air interface.
Handling Safety
On account of high operating temperature of 70 °C (+158 °F) care must be taken, if the tags are heated. To
avoid burn wait a while until the tags have cooled down or use gloves. At temperatures below 0 °C (+32 °F)
tags can be iced. In this case, wait a while until tags are warmed up or use gloves.
Battery Inside
All tags contain a battery. That is the reason for the following instructions:
Warning
Fire, explosion and burn hazard
Risk of explosion if battery is replaced by an incorrect type
Do not recharge, short circuit, crush, disassemble, heat above 70 °C (158 °F)
Do not incinerate, or expose contents to water
Electrostatic Discharge
This product contains components that are sensitive to electrostatic discharges. Please observe
the special instructions for their protection. Incorrect handling can damage the unit and cause the
invalidation of the warranty.
Safety Documents
This ILR system was designed, tested and supplied in perfect condition according to document test report
EN60950.
Condensation/Change of Temperature
Moving the systems from a cold to a warm environment could lead to dangerous situations due to
condensation. Therefore it must be ensured that the system can adjust itself to the warmer temperature.
Page 6 of 11
i-Q350L M
Spare Parts
We recommend that only original products, spare and replacement parts authorized by IDENTEC SOLUTIONS
be used for installation, service and repair. Otherwise IDENTEC SOLUTIONS does not accept any responsibility
for materials used, work carried out or possible consequences.
Page 7 of 11
Microtag Manual
3.1
Initial Operation
Configuration of The Tag
Important Note
Do not open the housing! Configuration is done using the built-in air interface of the i-Q350L M.
Configuration
The i-Q350L M is configured according to the specific application by the custom-specific host software.
Things to be configured
•
The ping rate: from 0.5 to 300 seconds in steps of 0.5 seconds
•
The number of bursts: from 0 to 15 (factory default setting: 5)
•
Broadcast Telegram Mode:
- ILR B2 (ASK) compatible with i-PORT MB, i-CARD CFB
- ILR 350 (FSK) compatible with i-PORT M 350, i-CARD CF 350
3.2
Tag Handling
The i-Q350L M is intended to be worn by individuals.
With its hook it can be fixed to clothing with snap-fastener straps or Velcro straps e.g. to a buttonhole.
The following picture gives an impression of the convenient size of the tag.
Page 8 of 11
i-Q350L M
4.1
Maintenance
General
In principle, the ILR system is maintenance-free. When correctly installed it operates for many years without
any problems.
4.2
Precautionary Maintenance
Regular checking to the system is recommended. Make sure that the housing of the tag has no damage. If
there are any damages as holes or cracks, the tags should be replaced and returned to IDENTEC
SOLUTIONS immediately.
Regular checking of all ports and cables belonging to the system is recommended. Unstable connections could
lead to damage and malfunctions of the system and therefore should be repaired as soon as possible.
A Brief Checklist
•
Are all housings intact?
•
Are all cables intact?
•
Are all connectors intact?
•
Are all connectors securely fastened?
•
Are all screws still tight?
•
Is there suddenly a malfunction at a specific unit?
4.3
Returns
Parts or main components returned for repair or exchange must be handled with great care. PC cards must be
returned in the appropriate ESD-protecting packaging material.
All returns should include a completed returns form (see appendix) and be sent to the local distributor or to:
IDENTEC SOLUTIONS AG
Service Department
Millenium Park 2
6890 Lustenau
AUSTRIA / AUTRICHE
Page 9 of 11
Microtag Manual
Technical Data
Operating Data
Operating frequency ILR-RFID
Transmission power
Compatibility
Standards/Certification
868 MHz (EU) or 920 MHz (NA), further frequencies on request
0.75mW (EU / NA)
depending on Broadcast Telegram Mode:
- ILR B2 (ASK) compatible with i-PORT MB, i-CARD CFB
- ILR 350 (FSK) compatible with i-PORT M 350, i-CARD CF 350
FCC Part 15 (US), ETSI EN 300 220 (EU)
Communication Data Long-Range RFID (ILR, Response Technology)
Multiple tag handling
Up to 2,000 tags in the read zone
Read/write range response mode
Up to 10 m (30 feet), free air*
Data rate response
19.2 to 115.2 kbits/s
Communication Data Long-Range RFID (ILR, Beacon Technology)
Read range broadcast
Up to 150 m (500 feet) free air*
Operation mode
Transmits marker information in at regular intervals
Repetition rate (ping rate)
0,5 – 300 seconds, adjustable in steps of 0,5 seconds
Data rate broadcast
115.2 kbits/s
* The communication range depends on the antenna type, the antenna cable runs and the
environmental conditions.
Communication Data Inductive Loop (Marker)
Read range
Up to several meters
Operating frequency
125 kHz (world-wide approved)
Operation mode
Receives marker ID number and transmits marker information several
times
Electrical Data
Power supply
Configuration
Ping rate
Number of Bursts
Environmental Conditions
Operating temperature
Shock
Vibration
Page 10 of 11
Lithium battery
Configurable from 0.5 to 300 seconds
in steps of 0.5 seconds
Configurable from 0 to 15
–30 to +70 °C (–22 to +158 °F)
50 G, 3 times acc. DIN IEC 68-2-27
several times onto concrete floor from 1 m height
3 G, 20 sine wave cycles, 5 to 150 Hz,
DIN IEC 68-2-6
5 G, noise 5 to 1.000 Hz, 30 minutes
DIN IEC 68-2-64
i-Q350L M
Mechanical Data
Dimensions
Casing
Mass
Protection class
Certifications
EMC
56 mm × 30 mm × 14 mm
Plastics
40 g
IP 65
CE (EN 300 220-1, -3; ETSI EN 301 489-1, -3),
FCC Part 15 (US), Industry Canada
Page 11 of 11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 11
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:75fad5e0-0551-4548-9652-7fbf838128db
Producer                        : AFPL Ghostscript 8.51
Modify Date                     : 2010:01:18 11:16:31+01:00
Create Date                     : 2009:12:16 12:17:27Z
Creator Tool                    : FreePDF 4.02 - http://shbox.de
Metadata Date                   : 2010:01:18 11:16:31+01:00
Document ID                     : uuid:ee2b858c-adfa-4f6d-a5cf-65978fb59d46
Format                          : application/pdf
Title                           : i-Q350L M - Hardware Manual
Creator                         : Administrator
Author                          : Administrator
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OO4-ILR-IQ350LM

Navigation menu