Identec Solutions IQ310CST Active UHF Transponder User Manual
Identec Solutions AG Active UHF Transponder
User Manual
ILR Series i-Q310 Transponders Models CST/SET/ATR/LPT/DRT/ATN Installation and Operation Manual i-Q 310 ISO 18000-7 Transponder Series Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents provide the information contained in this Manual on an “as-is” basis and do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non-infringement, reliability, fitness for a particular purpose, usefulness, completeness, accuracy or up-to-datedness. IDENTEC SOLUTIONS shall not in any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages. Trademarks “IDENTEC SOLUTIONS”, “Intelligent Long Range”, “ILR” and the stylized “i” are registered trademarks and “i-Q”, “i-D”, “i-B”, “i-CARD”, “i-PORT”, “i-LINKS”, “Solutions. It’s in our name.”, “Smarten up your assets” are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. Copyright Notice Copyright © 2009 IDENTEC SOLUTIONS. All rights reserved. No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS. Reg. No. IM.0782.EN Order Code: Issue 0 / June 2009 – 30. July 2009 – IDENTEC SOLUTIONS, Inc. Liberty Plaza II, Suite 375 5057 Keller Springs Rd, Addison, Texas 75001 USA Tel: (972) 535 4144, Fax: (469) 424-0404, Toll Free: 1 866 402 4211 info@identecsolutions.com www.identecsolutions.com Subject to alteration without prior notice. © Copyright IDENTEC SOLUTIONS 2009 Printed in Germany Page 2 of 23 i-Q 310 ISO 18000-7 Transponder Series Radio Frequency Compliance Statement IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: MODELS: EUROPE: USA Canada i-Q310 CST, i-Q310 SET, i-Q310 ATR, i-Q310 LPT, i-Q310, i-Q310 DRT, i-Q310 ATN CE FCC, HERO Industy Canada FCC ID OO4-IQ310 for Models i-Q310 SET, i-Q310 ATR, i-Q310 LPT, i-Q310 DRT FCC ID OO4-IQ310CST for Model i-Q310 CST FCC ID OO4-IQ310ATN for Model i-Q310 ATN Industry Canada: IC:3538A-IQ310 for Models i-Q310 SET, i-Q310 ATR, i-Q310 LPT, i-Q310 DRT IC:3538A-IQ310CST for Model i-Q310 CST IC:3538A-IQ310ATN for Model i-Q310 ATN HERO: USA: The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. European Notification according R&TTE Directive This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the following standards: ETSI EN 300 220, ETSI EN 301 489, EN 60950 USA Notification This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The device has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Page 3 of 23 i-Q 310 ISO 18000-7 Transponder Series Safety Precautions Important Safety Notes The system described in this manual is for exclusive operation by trained employees. Only qualified personnel that know the potential dangers involved should perform the installation, settings, maintenance and repair of the units used. On account of high operating temperature of 80°C (+176°F) care must be taken, if the tags are heated. To avoid burn wait a while until the tags have cooled down or use gloves. At temperatures below 0°C (+32°F) tags can be iced. In this case, wait a while until tags are warmed up or use gloves. The models i-Q310 SET, i-Q310 CST, i-Q310 ATR, i-Q310 LPT and i-Q310 DRT contain replaceable battery. Due to UL safety clauses this battery must be replaced only by skilled personnel. See also chapter Battery Replacement Procedure. All tags contain a battery. That is the reason for the following instructions: CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Operational Safety The correct and safe use of these systems assumes that operating and service personnel follow the safety measures described in the manual alongside the generally acceptable safety procedures. If there is a possibility that safe operation cannot be guaranteed the system must be switched off and secured against accidental use. Then the service unit responsible must be informed. Electrostatic Discharge This product contains components that are sensitive to electrostatic discharges. Please observe the special instructions for their protection. Incorrect handling can damage the unit and cause the invalidation of the warranty. Safety Documents This ILR system was designed, tested and supplied in perfect condition according to document testreport EN60950. Condensation/Change of Temperature Moving the systems from a cold to a warm environment could lead to dangerous situations due to condensation. Therefore it must be ensured that the system can adjust itself to the warmer temperature. Spare Parts We recommend that only original products, spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation, service and repair. Otherwise IDENTEC SOLUTIONS does not accept any responsibility for materials used, work carried out or possible consequences. Page 4 of 23 i-Q 310 ISO 18000-7 Transponder Series Page 5 of 23 i-Q 310 ISO 18000-7 Transponder Series Contents INTRODUCTION ........................................................................................................... 7 1.1 1.2 I-Q310 SERIES TRANSPONDER FUNCTIONALITY .................................................................. 7 CST AND SET FEATURES AND BENEFITS ........................................................................... 7 TECHNICAL SPECIFICATIONS...................................................................................... 8 TRANSPONDER DESCRIPTION..................................................................................... 9 3.1 3.2 3.3 3.4 HOUSING ................................................................................................................. 9 TRANSPONDER DATA MEMORY ..................................................................................... 10 USB INTERFACE ...................................................................................................... 10 BATTERY INSTALLATION AND POWER UP INDICATION ........................................................... 11 INSTALLATION...........................................................................................................12 4.1 4.2 4.3 4.4 SET MOUNTING OPTIONS ........................................................................................... 12 MOUNTING THE SET TRANSPONDER .............................................................................. 13 MOUNTING THE CST TRANSPONDER ............................................................................... 14 TRANSPONDER ENCLOSURE PROTECTION .......................................................................... 15 INITIAL OPERATION..................................................................................................16 5.1 5.1.1 5.1.2 5.1.3 ACTIVATING THE TRANSPONDER ................................................................................... 16 How to Activate the Transponder............................................................................ 16 Battery Replacement Procedure.............................................................................. 17 CST/SET LED description and operation................................................................... 18 5.1.3.1 Sensor LEDs ....................................................................................................................18 5.1.3.2 Light Sensor input ............................................................................................................18 5.1.3.3 Push Button.....................................................................................................................18 5.1.3.4 Humidity Sensor input .......................................................................................................18 5.1.3.5 BAT power LED ................................................................................................................19 5.2 CONFIGURATION ...................................................................................................... 19 USB OPERATION ........................................................................................................20 6.1 6.2 USING THE USB CONNECTION ..................................................................................... 20 DISCONNECTING THE USB CONNECTION ......................................................................... 20 MAINTENANCE AND TROUBLESHOOTING .................................................................21 7.1 7.2 7.2.1 7.3 TROUBLESHOOTING .................................................................................................. 21 TRANSPONDER BATTERY ............................................................................................. 21 Replacing the Transponder’s Battery ....................................................................... 21 RETURNS ............................................................................................................... 22 ASSOCIATED DOCUMENTS.........................................................................................23 Page 6 of 23 i-Q 310 ISO 18000-7 Transponder Series Introduction 1.1 i-Q310 Series Transponder Functionality The i-Q ISO 18000-7 transponders are high performance active RFID devices suitable for a wide variety of applications. The transponder responds to interrogator commands over the distance of 100 (and more) meters in line of sight. The transponders have a battery with a typical operational life of 3 or more years. This battery is easily replaceable in most models (ATR, DRT, LPT, SET and CST) for prolonged life span. The exception is the ATN transponder that has a non-removable sealed battery. The i-Q310 series includes the following transponders: • i-Q310 ATR = Asset Transponder • i-Q310 ATN = Asset Transponder with Non-Replaceable Battery • i-Q310 DRT = Data Rich Transponder • i-Q310 LPT = License Plate Transponder • i-Q310 SET = Sensor Transponder • i-Q310 CST = Container Security Transponder For description and instructions for ATR, ATN, DRT and LPT Transponders, please see a separate i-Q310 Series Installation and Operation Manual for ATR, ATN, DRT and LPT. 1.2 CST and SET Features and Benefits 100-meters (300 ft) read/write range allows automated identification, tracking and tracing of assets without human intervention. The CST and SET transponders offer two memory areas. The SET and CST have 128kB of memory allocated for user data The SET and CST have 32 bits of memory allocated for a fixed, unique, Identification Code. The SET and CST have 32kB of memory allocated for sensor logging. 433 MHz operating frequency allows low-power, long communication range and high data transmission rates with minimal interference due to local conditions. ISO / IEC 18000-7 compatible allows manufacturer independent interoperation. US DoD and NATO ITV compatible. All transponders carry a speaker for acoustic signalization during search, locate, alarms. The CST and SET transponders provide USB 2.0 Hardwire Interface for fast and secure data transfer with USB connection with mini-B connector. 3-year battery lifetime and more delivers long-time maintenance-free operation, without battery replacement. CST and SET transponders have a replaceable battery for extended lifetime. Communication on demand eliminates RF flooding through software-controlled read/write operations. Non-line-of-sight data transmission allows tags to be buried while transmitting for improved tracking and tracing efficiency. Page 7 of 23 i-Q310 ISO 18000-7 Transponder Series Technical Specifications Performance Read rate Up to 100 tags/s (Collect Tag Identification Code only) Max. response time < 150 ms (single tag) RF Communication Read range Write range Operating frequency Data rate (download to tag) Data rate (upload to reader) Frequency Modulation Sensitivity Maximum transmission power Standard / Certification Up to 100 m (300 feet) @ free air Up to 100 m (300 feet) @ free air 433.92MHz 27.778 Kbits/s 27.778 Kbits/s 433.92MHz international ISM band FSK ± 50 kHz at 27.778 kHz data rate -85dBm / range at least 300ft (~100m) 1mW– comply with national regulations ISO/IEC 18000-7 Hardwire Communication Standard Connector USB 2.0 Mini-B Electrical Power source Expected battery life Battery monitoring Lithium battery (replaceable, except ATN) Typically 3 years and more depending on usage Yes Data Data retention Write cycles Memory size Identification code >10 years without power 100,000 writes to a tag 128k bytes/32k bytes 32 bit fixed ID Environmental Operating temperature Humidity Shock Vibration Physical Dimensions (CST) Weight (CST) Dimensions (SET) with bracket Dimensions (SET) without bracket Weight (SET) Enclosure Enclosure rating –40°C to +80°C (–40ºF to +176ºF) 10% to 90% relative humidity at 30°C (+86ºF) 50 G, 3 times DIN IEC 68-2-27 Multiple drops to concrete from 1 m (3 ft) 3 G, 20 sine wave cycles, 5 Hz to 150 Hz, DIN IEC 68-2-6 5 G, noise 5 Hz to 1000 Hz, 30 minutes DIN IEC 68-2-64 7 in. length x 4.24 in. width x 3.97 in height. (17.7 cm x 10.7 cm x 10 cm) 200 g (7 oz) 6.25 in. length x 2.15 in. width x 1.75 in. height (15cm x 5.5 cm x 4.5 cm) 5.76 in length x 2.17 in width x 1.53 in height (14.6 cm x 5.5 cm x 3.9 cm 100 g (3.52 oz) Plastic (ASA / Luran® S) IP 65 Page 8 of 23 i-Q310 ISO 18000-7 Transponder Series 3.1 Transponder Description Housing The SET and CST i-Q310 transponders are made of a rugged plastic housing with IP 65 rating. On the front side (see Fig. 3.1 and 3.2) there are identification labels, which provide information about the type of the tag, the tag manufacturer and prime contractor, certifications, barcode and the IAW MIL-Std-129P markings where appropriate. On the rear side of the transponder, there are brackets with openings for transponder mounting and for clip-on magnetic mounts. The SET and CST transponders have identical front panel markings, sensors, and LEDs. Product label Sensor LEDs Light Sensor input Push Button Humidity Sensor input USB cover Battery cover Figure 3.1 Front view of the SET transponder Page 9 of 23 i-Q310 ISO 18000-7 Transponder Series Figure 3.2 Front view of the CST transponder 3.2 Transponder Data Memory The CST and SET models of the i-Q310 series transponders offer 128 kBytes of non-volatile memory for general purpose and user data. In addition, 32kBytes of non-volatile memory is available for sensor logging. 3.3 USB Interface The transponders are enabled for fast and secure data transfer using USB connection with mini-B connector. The USB connector is placed next to the battery cap under a separate cover (Fig. 3.3). Page 10 of 23 i-Q310 ISO 18000-7 Transponder Series Figure 3.3 USB connector 3.4 Battery installation and power up indication The transponder ships with the battery reversed; please see Chapter 5 for details on how to power and activate the transponder. Page 11 of 23 i-Q310 ISO 18000-7 Transponder Series 4.1 Installation SET Mounting Options The transponders are designed with two mounting holes so they can be firmly mounted onto virtually any surface. The transponder can be mounted using various methods dependent on the particular application. Among the common types of mounting are: • Screws • Rivets • Double sided tape • Wire ties • Mounting bracket (Fig. 4.1 and 4.2) • Magnetic mount (Fig. 4.3) Figure 4.1 The SET mounting bracket Figure 4.2 Installing the SET transponder into the bracket Page 12 of 23 i-Q310 ISO 18000-7 Transponder Series Figure 4.3 Magnetic mount installation for the SET 4.2 Mounting the SET Transponder The transponder has slots that allow mounting using wire ties without the mounting bracket. The mounting bracket has also openings in order to be wire tied to a post or other object (Fig 2.4). Figure 4.4 SET Mounting with wire ties Page 13 of 23 i-Q310 ISO 18000-7 Transponder Series 4.3 Mounting the CST transponder The CST is intended for ISO shipping containers like the one shown below in Fig 4.5. Figure 4.5 ISO container (typical) The CST transponder is shown below mounted in various orientations. The ISO door mount opening on the CST is 55mm (2.17”) shown in Figure 4.6. It must be mounted on the left door with the antenna outside the container and the sensor body and switch mounted inside the container, shown in Figs 4.8 and 4.9. The roller switch arm shown in Fig 4.6 and 4.8 should contact the right door to detect a breach or opening of the door. Figure 4.6 CST door mount opening Page 14 of 23 i-Q310 ISO 18000-7 Transponder Series Figure 4.7 CST inside left door mounting Figure 4.8 CST inside left door mounting 4.4 Transponder enclosure protection The CST and SET transponders all have enclosures rated at IP 65. This means that the transponders are dust tight and water tight. However care should be taken to not immerse in liquids or subject to powerful jets of water. The transponder casing should not be opened at any time in order to preserve the integrity of the IP 65 rating and maintain the factory seal. Figure 4.9 Transponder seal Page 15 of 23 i-Q310 ISO 18000-7 Transponder Series 5.1 Initial Operation Activating the Transponder The i-Q310 ISO 18000-7 transponders needs to be activated. They are shipped with a reversed battery to prevent communication and battery consumption (Fig. 5.1). Figure 5.1 Battery shown reversed with the negative (-) terminal shown. 5.1.1 How to Activate the Transponder Before use, the battery cover has to be opened, battery flipped over and securely closed. This activates the transponder for operation. Use only A size 3.6 V Lithium Li-SOCl2 batteries. Figure 5.2 Battery shown in correct orientation with the positive (+) terminal shown. Page 16 of 23 i-Q310 ISO 18000-7 Transponder Series 5.1.2 Battery Replacement Procedure Before starting battery replacement regard following instructions: 1. Due to UL safety clauses this battery must be replaced only by skilled personnel. 2. Warning Fire, explosion and burn hazard Risk of explosion if battery is replaced by an incorrect type Do not recharge, short circuit, crush, disassemble, heat above 100°(212°F) Do not incinerate, or expose contents to water 3. Use only A size 3.6 V Lithium Li-SOCl2 batteries, preferred type: Saft LS 17500 4. Do not replace the battery or open the battery compartment outdoors or in cold or moist environment. Always replace it in a warm and dry place. If the tag has been brought from a cold (less than 10 °C/50 °F) into a warm environment it should warm up for 1hour. 5. Do not dispose used batteries into household waste. Used batteries are hazardous waste. 1. Remove the battery cover by rotating counter clockwise while slightly depressing cover (Fig 5.3). Figure 5.3 Opening the Battery Cap 2. Remove the battery and put it back with the poles reversed (Fig. 5.2). The ⊕ should point out. 3. Replace the battery cover by rotating it clockwise while slightly depressing it. 4. When you hear a short beep, the transponder is activated and ready for operation (see section 5.1.3). 5. If no beep is heard, either the battery is not oriented correctly or it needs to be replaced. 6. Follow steps 2 – 4 for battery replacement in case of depletion. Note: To keep moisture and dust out of the transponder take care to not lose the o-ring seal on the battery cover or to leave the battery cover off the transponder for extended periods. Page 17 of 23 i-Q310 ISO 18000-7 Transponder Series 5.1.3 CST/SET LED description and operation Light Sensor Push Button Humidity Sensor Figure 5.4 LED indicators and sensor inputs 5.1.3.1 Sensor LEDs The sensor LEDs are illuminated when……….??? 5.1.3.2 Light Sensor input Need description for content 5.1.3.3 Push Button Need description for content 5.1.3.4 Humidity Sensor input Need description for content Page 18 of 23 i-Q310 ISO 18000-7 Transponder Series 5.1.3.5 BAT power LED The SET and CST transponders have an LED for battery status as indicated in Fig 5.4. If the battery has more than a 15% charge remaining the LED will be green. Below this level the battery warning flag is set in memory, and the LED will illuminate red. The battery LED will be off when the battery charge is depleted or not installed. 5.2 Configuration The i-Q310 series transponders are not configured directly. They are configured using the i-PORT M-310 device via the air interface and appropriate software. Please see the FDU and Handheld User’s Guide for information on how to configure transponders. Page 19 of 23 i-Q310 ISO 18000-7 Transponder Series USB Operation Important Note While a transponder is connected via USB to a PC it is continuously powered by the internal battery. In order to save battery life, please close the USB connection and remove the transponder from the USB connection after data transfer. On account of high operating temperature only use usb cable specified up to +80°C (+176°F). 6.1 Using the USB Connection Please see the FDU Software Manual for details. 6.2 Disconnecting the USB Connection As the transponder is not operating as a USB mass storage device with buffers that must be flushed before removal, it is quite easy to disconnect it from the USB connection: • Stop the service software or cancel the connection to the transponder in the service software. • Remove the transponder from the USB connection. • Protect the USB connector by safely tightening the protective rubber lid of the transponder. Page 20 of 23 i-Q310 ISO 18000-7 Transponder Series 7.1 Maintenance and Troubleshooting Troubleshooting The transponder does not respond to interrogation at all. • Make sure the battery is inserted in a correct orientation. • Make sure the battery is not depleted. Change the battery. • Tighten the battery cap in order to ensure that both poles are in contact with the transponder’s circuits. The transponder is not accessible through USB. • Ensure that the USB cable is tightly plugged into the transponder and the host PC. • Switch the USB cable. • Are the correct drivers installed, communication configured? Please refer to the FDU Software User’s Manual. Other issues: If none of the above steps resolved the issue or there are other issues with the transponder not mentioned here, please contact technical support. 7.2 Transponder Battery The battery of the transponder has a typical lifetime expectancy of more than 3 years. A depleted battery can be replaced with a new one. 7.2.1 Replacing the Transponder’s Battery For steps on how to replace the battery, please see Chapter 5. Safety Instructions Do not replace the battery or open the battery compartment outdoors or in cold or moist environment. Always replace it in a warm and dry place. If the transponder has been brought from a cold (less than 10 °C/50 °F) into a warm environment it should warm up for 1 hour. Replace the battery only with a type provided by or recommended by IDENTEC SOLUTIONS. The battery has to be disposed as special refuse. Important Note If the battery is replaced after the transponder has signaled a “battery low” status, simply replace the battery following the description in advance. The transponder will automatically recognize the battery exchange and will automatically reset its battery usage counter. If the battery is replaced on a regular precautionary basis without the “battery low” signal, after replacing the battery, the transponder needs a service command in order to reset its battery usage counter. Page 21 of 23 i-Q310 ISO 18000-7 Transponder Series 7.3 Returns Parts or main components returned for repair or exchange must be handled with great care. All returns should include a completed returns form (see appendix) and be sent to: IDENTEC SOLUTIONS, Inc. 5057 Keller Springs Rd., Ste 375 Addison, TX 75001 USA Page 22 of 23 i-Q310 ISO 18000-7 Transponder Series Associated Documents Manuals IM.0780.EN IM.0781.EN IM.0782.EN IM.0783.EN System Description, English i-PORT F310 Hardware and Installation Manual, English i-Q310 Series Transponder Installation and Operation Manual for ATN, ATR, DRT and LPT, English i-PORT H310 Handheld Interrogator Module, English Data Sheets ID.0680.EN ID.0681.EN ID.0682.EN ID.0683.EN ID.0684.EN ID.0685.EN ID.0686.EN ID.0689.EN i-PORT F310, English i-Q310 ATN—Asset Transponder, English i-Q310 ATR—Asset Transponder, English i-Q310 DRT—Data Rich Transponder, English i-Q310 SET—Sensor Transponder, English i-Q310 LPT—License Plate Transponder, English i-Q310 CST—Container Security Transponder, English i-PORT H310 Handheld Interrogator Module, English Page 23 of 23
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 23 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:89090234-9db4-4e51-8df7-327e70c92a1b Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2009:08:31 16:08:41+02:00 Create Date : 2009:08:03 11:11:18Z Metadata Date : 2009:08:31 16:08:41+02:00 Document ID : uuid:50bb161b-2453-4c99-a300-ad76fb69dfad Format : application/pdfEXIF Metadata provided by EXIF.tools