User's Manual
Please note the important information below before reading this manual.
NOTE
고
주의
NOTE
고
DANGER
Warning
참조
주의
Failure to comply with safety warnings and regulations can cause serious injury or death.
DANGER
주의
Caution
참조
주의
Failure to comply with safety cautions and regulations can cause injury or property damage.
For any problems with BSM170/170B or any clinical questions, please contact us at the following:
InBody Co., Ltd. [HEAD OFFICE]
InBody Bldg., 54, Nonhyeon-ro 2-gil, Gangnam-gu, Seoul, Korea
TEL: +82-2-501-3939 FAX: +82-2-578-2716
Website: http://www.inbody.com
E-mail: info@inbody.com
Reproduction, adaptation, or translation of this manual is prohibited without prior written consent from InBody Co., Ltd
under the copyright laws. This manual might have typographical errors, and its content can be changed without a prior
notice. InBody Co., Ltd. shall not be liable for any errors, incidental, or consequential damages that occurred by not
complying with the content of the User's Manual.
Visit our website http://www.inbody.com to view and download further information about the functions of
the BSM170/170B, the explanation of results output, and more. InBody Co., Ltd reserves the right to modify
the appearance, specifications, and etc. of the BSM170/170B to improve the quality of the product, without
prior notice for reasons of performance improvement.
Customer Service Information
InBody USA [USA]
13850 Cerritos Corporate Dr., Unit C, Cerritos, CA 90703, USA
TEL: +1-323-932-6503 FAX: +1-323-952-5009 Website: http://www.inbodyusa.com
E-mail: USA@biospaceamerica.com
InBody Japan Inc. [JAPAN]
Second Floor Ayabe Bldg., 2-17-3 Sotokanda, Chiyoda-ku, Tokyo JAPAN
TEL: +81-03-5298-7667 FAX: +81-03-5298-7668 Website: http://www.inbody.co.jp
E-mail: inbody@inbody.co.jp
EU Representative. [EUROPE]
DongBang Acuprime. 1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, U.K
TEL: +44-1392-829500 FAX: +44-1392-823232 Website: http://www.inbody.com E-mail: info@acuprime.com
Biospace China. [CHINA]
904, Xing Di Plaza, No. 1698 Yishan Road, Shanghai, 201103, CHINA
TEL: +86-21-64439738, 9739, 9705 FAX: +86-21-64439706 Website: http://www.biospacechina.com
Australian Sponsor. [AUSTRALIA]
E-mail: info@biospacechina.com
Emergo AUSTRALIA. Level 20, Tower Ⅱ, Darling Park, 201 Sussex Street, Sydney, NSW 2000, AUSTRALIA
TEL: +61-2-9006-1662 FAX: +61-2-9006-1010 Website: http://www.emergogroup.com E-mail: Sponsor@emergogroup.com
ⓒ2014 InBody Co., Ltd. All rights reserved. BM-ENG-E9-B-140827
User’s Manual Contents
I. Stadiometer Installation
A. Product Components
B. Operating Environment
C. Installation Instructions
D. Stadiometer Settings
12
E. Maintenance
18
II. Height Measurement
A. Precautionary Measurements
19
B. Measurement Instructions
20
C. Measurement Posture
21
III. Transportation and Storage
A. Repacking Instructions
22
B. Transportation and Storage Environment
22
IV. Frequently Asked Questions
23
V. Others
A. Exterior and Functions
24
B. Symbols
26
C. Specifications
27
I. Stadiometer Installation
A. Product Components
The BSM170/170B contains of the following components.
Make sure all of the following components are present.
* Please inspect each component of the BSM170/170B for damage prior to installation.
❶ Footplate 1 EA
❷ Stand (upper) 1 EA
❸ Stand (lower) 1 EA
❹ Measurement unit 1 EA
❺ Measurement tape 1 EA
❻ Footplate mounting screws 4 EA
❼ Stand mounting screws 8 EA
❽ User’s manual 1 EA
❾ AA batteries 4 EA
❿ Test Jig 1 EA
❶
❹
❷
❸
❺
➑
➒
사용자
매뉴얼
❼
❻
➓
B. Operating Environment
ON
Please make sure that the environment is adequate for the BSM170/170B installation. This equipment is designed
for indoor use. If installing outdoors, the following requirements must be fulfilled.
NOTE
Temperatures range
10 ~ 40℃ (50 ~ 104℉)
Relative humidity
30 ~ 75% RH
Atmospheric pressure
70 ~ 106kPa
DANGER
참고
주의
•
Warning
참조
주의
Before installing BSM170/170B, check that the ceiling is at least 2.3 m high. The maximum height of this
equipment is 2.19m. Keep a space of at least 3cm between the ceiling and the top of the BSM170/170B.
C. Installation Instructions
ON
1. After opening the BSM170/170B box, remove the packaging materials and take all product components out.
NOTE
참고
DANGER
주의
Warning
참조
주의
•
Keep the packaging materials provided for repacking the equipment in the future. Other wastes should be
disposed of according to relevant laws and regulations.
•
Install the BSM170/170B on a leveled, non-vibrating surface. Installing the equipment on an uneven surface may
cause the examinee to fall down. Measurement results may also be inaccurate.
•
Never clean the BSM170/170B with liquid spray or detergent directly. The equipment may corrode and/or
malfunction if the liquid or detergent leaks inside. Additionally, BSM170/170B measurement tape may be damaged.
When cleaning the BSM170/170B, gently wipe it with the cloth.
		 2. Insert the “Stand (lower)” into the footplate, ensuring that the arrow (▼) located on the bottom right of
			 the “Stand (lower)” and the arrow (▲) located on the footplate face one another.
* When inserting into the “Stand (lower)”, part without screw holes must face downward.
* The “Stand (lower)” and the footplate are designed to be assembled together in only one particular direction. Forcing the stand to
be inserted in other directions could damage the product.
		 3. Hold the “Stand (lower)” in place to prevent it from sliding out of the insertion hole of the footplate,
			 tilt the equipment sideways towards the floor.
		 4. Screw each of the 4 footplate leveling screws into the holes located on the opposite side of the stand
			 insertion hole of the footplate.
5. Tighten the Stand mounting screws by turning them clockwise with the Phillips screwdriver.
UTION
6. Once all four screws as fastened tightly, return the “Stand (lower)” and footplate to an upright position.
7. Insert the black end of “Stand (upper)” into the “Stand (lower)” as illustrated below.
NOTE
참고
DANGER
Caution
참조
주의
•
주의
Hold the “Stand (upper)” as vertically as possible so that it is not inserted in a slanting position.
		 8. After inserting the “Stand (upper)” into “Stand (lower)”, fasten the two stands together using the mounting
			 screws and Phillips screwdriver.
UTION
NOTE
참고
DANGER
주의
•
Caution
참조
주의
Avoid using excess force to fasten the mounting screws.
		 9. Insert the measuring tape into the “Stand (upper)” with the ̒↓̓ facing down. Refer to the illustration below.
			 After the measurement tape is completed inserted, remove the sticker attached to the end of the measurement
			 tape to affix the tape to the stand.
UTION
NOTE
참고
DANGER
주의
Caution
참조
주의
•
The measurement tape must be inserted with the arrow marked ‘↓’ facing down.
•
Correct measurements cannot be taken if the measurement tape is inserted reversed.
AUTION
10. Tilt the Stand to a comfortable position and insert the measuring unit onto the stand as illustrated below.
NOTE
참고
DANGER
주의
•
Caution
참조
주의
The LCD on the measurement unit and the measurement tape must be visible on the same side.
11. The BSM170/170B uses batteries as its power source.
* When the measurement standby time expires, the equipment automatically turns off.
➊ BSM170 standby time: 10 seconds.
➋ BSM170B standby time: 2 minutes if it is not connected to the InBody, 10 seconds if it is connected to the InBody.
1) Open the battery cover located on the right side of the LCD screen.
2) Insert 4 AA batteries.
3) Cover the battery socket with the battery socket lid.
		 12. After placing the BSM170/170B on a flat surface, the footplate is not level, use the footplate adjustment
			 screws to adjust until level.
* Leveling the equipment is necessary for accurate height measurements.
footplate leveling screws
		 13. When taking measurements with the BSM170/170B, the operator must move the measurement unit up and down
			 manually. By default, the adjustment screw is tight to keep the measurement unit from sliding down too freely.
			 If the screw is too tight, adjust the screw to the preferred tightness.
* By default, the adjustment screw is tight to keep the measurement unit from sliding down too freely. If the screw is too tight,
adjust the screw to the preferred tightness.
* If the screw is tightened too tight, the measurement unit may not move at all.
Measurement unit adjustment screws
10
14. Turns on the BSM170/170B.
		 15. Move the measurement unit up or down until the ‘Move’ text disappears. The equipment will enter the
			 measurement standby mode and the display will change as shown below.
11
D. Stadiometer Settings
1. Requried Settings
			 1. After turning on the BSM170/170B, press and hold the
				 for at least 3 seconds to enter the Setup menu.
button and the
button simultaneously
			 2. In the Setup menu, set the measurement value hold time, beep, screen brightness, units, and offset value.
				 1) Measurement value hold time: When the
button is pressed after a height measurement is recorded,
					 the value displayed will stay locked on the LCD screen for this amount of time, even if the measurement
					 unit is moved.
					 a. Use the
button to move to ‘Hold’ and then press the
button to select.
					 b. Use the
button to set a hold time for the locked height value.
						 * The hold time can be set to off or on for anywhere between 1 to 10 seconds.
Measurement value hold time setup
					 c. Save changes by pressing the
12
button.
				 2) Beep: Enable or disable the beep alert.
					 a. Use the
button to move to ‘Beep’ and then press the
					 b. Use the
button to turn on or off the beep alert.
button.
						 * Beep can be set to on or off.
Beep setup
					 c. Save changes by pressing the
button.
				 3) Screen brightness: Brightness of the LCD screen.
					 a. Use the
button to move to ‘Light’ and then press the
button.  
					 b. Use the
button to set the screen brightness that is appropriate for the test environment.
						 * Screen brightness can be set to 100%, 50%, or off.
Screen brightness setup
					 c. Save changes by pressing the
button.
13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Modify Date                     : 2014:09:24 11:42:06+09:00
Create Date                     : 2014:09:24 11:42:06+09:00
Metadata Date                   : 2014:09:24 11:42:06+09:00
Creator Tool                    : Adobe InDesign CS4 (6.0.6)
Format                          : application/pdf
Document ID                     : uuid:2a52e0ac-4a1f-4adc-9c2d-b543cfb089e1
Instance ID                     : uuid:31c783a6-f575-447e-ae1d-2ad16fc6327b
Producer                        : Adobe PDF Library 9.0
Page Count                      : 13
Creator                         : Adobe InDesign CS4 (6.0.6)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F6OBSM170B

Navigation menu