InBody INBODYBAND2 Body Composition Analyzer User Manual InBodyBand2 manual ENG 80x40 161125

InBody Co., Ltd. Body Composition Analyzer InBodyBand2 manual ENG 80x40 161125

User Manual

• Charge the InBodyBAND prior to initial use.    During the test, your hands MUST NOT come in contact with each other.• For accurate measurements, please enter the correct personal information   when you sync your InBodyBAND with the InBody App.Please read the following before initial use.© 2016 InBody Co., Ltd. All rights reserved. BM-ENG-J0-B-161031InBody Co., Ltd.InBody Bldg., 54, Nonhyeon-ro 2-gil, Gangnam-gu, Seoul 06313 KoreaWebsite: www.inbody.com   Customer Support: homehealth@inbody.comCharging and Powering UpInBodyBAND ModesInBody Test: Measure your percent body fatHeart Rate measurement: Measure your HRStep Count: Daily step count Active minutes: Duration of walking/runningCalories: Burned calories from walking/runningActive Distance: Distance traveledInstalling the InBody App1. Search “InBody” in the Google Play Store   or the  Apple App Store. 2. Download the InBody App. 3. Load the App and follow the on-screen instructions to sync your InBodyBAND   with your phone.Transferring dataStep count and sleep tracking data will beautomatically updated when the InBodyBANDis synced with the App.※ In the event the App fails to automatically update,  you can initiate a manual sync from the Steps Menu. Creating an Account1. Enter your mobile phone number after   starting the InBody App. 2. Enter your gender, height, age, and password. 3. Finish registration by pressing Done.1234567890Setting Up the DeviceInBody Test 1. Press InBody Test at the bottom of the  main screen. 2. Enter your current weight and start the  InBody Test.3. After the test, results will be automatically  uploaded to the App. ※  In order to keep track of your InBody Test results,  the InBody Test must be initiated through the  InBody App. ※ Proper posture for InBody TEST & Heart Rate measurment.Instructions1. Please charge the InBodyBAND using the charging dock. 2. Once the InBodyBAND is securely connected to the charging dock, it will automatically turn on while charging.  ※ Full charging requires approximately 1 hour※ The device CANNOT operate while charging..1.    →Select the ‘InBodyBAND2’ to bring up the setup screen.Go to ‘Device’ in the setup menu2. Press Confi rm after entering weight.3. InBodyBAND will vibrate to indicate successful connection between the InBody App and the device.
Symbol DefinitionsWarning, Caution, NoteDirect currentEuropean ConformityManufacturerThe Waste Electrical and Electrical Equipment Regulations indicates separate collection for electrical and electronic equipment* Specifications may change without prior notice.SpecificationsCountry of OriginBand MaterialMeasurement CurrentBattery LifeRecharging TimeDimensionsWeightWristsColorInput PowerOperation ConditionsKorea, Republic ofTPSIV90 μA and belowA fully charged InBodyBAND has a maximum battery life up to two weeks. (Battery life and charge cycles may vary depending on frequency of use, configuration, and other factors)Approx. 1 hour18.0 mm(W) × 42.0 mm(L) × 10.5 mm(H)20g M: 15 ~ 19 cm Black, Grey, WineOperating Voltage: 3.7 VDC, Charge Voltage: 5.0 VDC10 ~ 40ºC(50 ~ 104ºF), 30 ~ 75%, 70 ~ 106kPaFrequency UsedNo. of ChannelsModulation TypeWattageTransport and Storage Conditions -10 ~ 70ºC(14 ~ 158ºF), 10 ~ 80%, 50 ~ 106kPa2402 MHz ~ 2480 MHz40GFSK1 mW and belowFCC InformationThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.Note: This equipment may generate or use radio frequency energy. Change or modification to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.End product labelingThe label for end product must include “Contains FCC ID: F60INBODYBAND.”Warning• Individuals with artificial electrical implants such as a defibrillator or pacemaker  should not take the InBody Test. Electrical currents of the InBodyBAND    may disrupt the functionality of life-sustaining implants.• Electrical currents used by the InBodyBAND is not harmful to the body,    but pregnant women are advised to consult with an expert before use.Caution• May not be used for treatment or medical diagnosis.• Results may vary depending on physical and environmental conditions.• Tests should be taken indoors in the event of cold weather   (Body Composition & Heart Rate).Testing PrecautionsCaution• The InBodyBAND is water-resistant in simple daily activity such as washing hands or taking a shower.• This product has been tested in a controlled environment and is water- and dust-resistant for typical    day-to-day situations (satisfies the requirement for IP67 Level of International standard IEC 60529-Degrees     of Protection provided by Enclosure[IP Code]). However, the InBodyBAND may not resist water in all   situations and may become damaged in certain circumstances. • Do not disassemble or modify the equipment, including the internal parts, without written consent from the manufacturer. This may cause electric shock or injury, product malfunction, inaccurate results, and will void     the manufacturer’s warranty.• Do not open the enclosure, disassemble, break, deform, bend, smash, press, or make a hole in the product.      The battery may explode.• Do not use your InBodyBAND if damaged It could be a cause of fire, burn, injury and electric shock.• Some damage, such as when water label become discolored due to use and/or negligence are not   subject to warranty.• Do not expose the InBodyBAND to excessive liquid, moisture, humidity or rain.• Do not swim with the InBodyBAND or use it in water.• Do not use your InBodyBAND after placing it in water for a long period of time.• Do not leave your InBodyBAND where large amounts of water can be splashed on the product.• Do not place the InBodyBAND in salt water/chemicals.• Do not use the InBodyBAND underwater or place it in high-pressure water environments.• Excessively bending the InBodyBAND may cause damage to the product.• Do not drop/grve impact to the InBodyBAND. Such actions may result in damage.• Keep out of reach of children. The InBodyBAND can be a choking hazard.• Those allergic to metal, rubber and silicon materials must not use the InBodyBAND.• Battery must not be deformed, changed, added with other substances, or exposed to water or other liquids.• Do not expose your InBodyBAND and charger under UV light for long periods of time.• Do not use your InBodyBAND in excessively humid environments.• Use the InBodyBAND in room temperature to maximize its battery capacity. Usage of the product in low  temperature may cause a decrease in battery capacity.• Users with sensitive skin and/or who wear the InBodyBAND tightly may experience skin reactions.• Users who are exposed to external irritants such as sweat, soap, allergens, etc. may experience skin     reactions while wearing the InBodyBAND. • Please ensure that the InBodyBAND remains dry and clean. This product, although in compliance with  international safety standards, can cause such as allergic reactions in some people.• Do not place the InBodyBAND near a bathtub, sink, sauna, pool, or steam room. Exposure of the      InBodyBAND to excessive moisture could result in deformation/failure/explosion.• Please use InBodyBAND properly as instructed in this manual.• Do not cover the InBodyBAND with any fabrics while charging. Doing so may cause a fire.• Do not check call notifications or other data on the product’s display while driving or in other situations     where distractions could be hazardous.• Clean and dry your InBodyBAND regularly, especially areas in contact with the skin. Use a clean, damp  cloth. Do not wash the product with water.• The InBodyBAND’s strap may be contaminated or discolored by cosmetics, direct sunlight, water, oil or etc.• Do not apply excessive force to InBodyBAND while it is connected to the USB cradle cable.• Please be careful not to break the USB cradle cable. Discontinue usage if the USB cradle cable is   damaged.• The InBodyBAND is classified as Class B electromagnetic radio equipment and can be used anywhere.• Do not use the InBodyBAND if you have life-sustaining medical implants as the radio waves emitted by  the InBodyBAND may interfere with the implants.• Keep the hand electrodes and the arm electrodes away from electricity conducting materials. Electrical     stimuli such as strong static electricity may cause malfunction or damage of the product.• Bluetooth devices may cause electromagnetic interferences with multiple electronic goods due to use     of the same frequency range.• Electromagnetic interferences may occur while the product is operating. Do not use the InBodyBAND    for any services related to human life. In case of a medical emergency or other urgent situation, please     use a smartphone to check any incoming communication.• The user is responsible for data transfer problems caused by using the Bluetooth function and illegal      use of Bluetooth function.• If the device is broken, get in touch with the store where you purchased from or get in touch with InBody.    The user is responsible for problems caused by any unlicensed repairs. Note• Use a lint-free cloth to gently wipe the external surface of the equipment once every week. • Specifications and user manual may change without prior notice.General PrecautionsPlease read these safety warnings carefully to ensure your personal safety and toprevent property damage.Testing Instructions1. Maintain the proper posture during the test   as shown in the image on the right.2. Your hands MUST NOT come in contact with  each other.3. For accurate measurements, place the  product on the same spot on your wrist for   every test and test it at the same point of  time in your daily routine.Avoid contact

Navigation menu