Version May 1999   1         ELITE 770 *  User's Manual  Version May 99
Terminal ELITE 770  2
Version May 1999   3  INGENICO 9, quai de Dion Bouton 92816 Puteaux cedex  RCS Nanterre B 317 218 758 - SIRET 317 218 758 00033 DIV0510A  Table of contents   I- PRESENTATION OF THE TERMINAL 5 1- Introduction 5 2- The Terminal 6 3- The connections 6 4- The Keyboard - Principles of Utilisation 8 5- The Card Reader 9 6- Portable Functioning 9 II- ELITE 770 TECHNICAL OVERVIEW 11 1- Terminal feature 11 2- Display 11 3- Printer 11 4- RS232 Interface 12 5- RS232 Connection 12 6- Modem 13 7- SIM Interfaces 13 8- Technical Specifications 14 III- PROCEDURES OF INSTALLATION 16 1- Configuring Radio Link 16 2- Entering the Date and the Time 17 3- Telephone Network Parameters 18
Terminal ELITE 770  4   4- Configuration Receipt 19 5- Option « Table Number » 19 6- Application Software Downloading Procedure 20 IV- SECURITY RECOMMANDATIONS 21
Version May 1999   5  I- Presentation of the terminal 1- Introduction The ELITE 770 is a portable payment terminal. This terminal was created to process all payments made by magnetic or smart cards.    The ELITE 770 terminal benefits from a modular conception which permits it to treat all cards of different types using separate corresponding programs. It is therefore important to understand the manner in which it functions, at the modular and the terminal level.  0 The Modular Level These functions link up with and correspond to the many different types of cards that the terminal processes, the most important of which is the principal function of payment.  0 The Terminal Level There are a certain number of functions that are the concern of a ‘global treatment’ and not of a particular module.  The terminal level is the superior level and is common to all modules.  This level does not depend on the number or the nature of each module.     In its base version the ELITE 770 terminal is equipped with a module that permits it to process Bank Cards.  Your retailer or installer will be able to give you all the necessary information on all modules on offer and their installation details.
Terminal ELITE 770  6   2-  The Terminal The terminal case contains the following elements : The portable terminal itself, • A base. • The cable that connects the terminal to a telephone line. • The block sector that connects the terminal to a 115 or 230 volts power point (depending on the country) 3- The connections 0 Telephonic Connection The compact telephonic cable connection that is supplied with the Elite terminal, must be introduced into the terminal plug, marked with the symbol . The telephone connection (RJ11) must be introduced into the telephone socket in the wall.  .                                Telephonic line  0 Electrical Connection The small jack connection to the block sector is plugged into the connection marked with the symbol  on the terminal.  The twin pronged electrical plug of the block is connected to an electrical point of 115 or 220 volts (depending the country).  Power Supply  0 Connection with an External Peripheral Certain peripheral devices such as a check reader can also be connected.
Version May 1999   7  The ELITE 770 terminal must be powered off before connecting the cable on the base, to the RS232 port.. Serial port
Version May 1999   8  4- The Keyboard - Principles of Utilisation • The   key permits the operator to access the corresponding modular level functions   • The    and   keys permit to access to the terminal level functions and to the system menu   • The key  ↑↑  permits a paper feed of a couple of centimetres   • The GREEN key permits the validation of any information read by  or entered into the terminal   • The RED key cancels the occurring command after which, it returns  the terminal to the idle state   • The YELLOW key deletes the last character entered, and is used  in certain cases where an override is requested   • The key marked 00 can only be used for entering amounts ;  more particularly it permits the operator to enter amounts in cents
Version May 1999   9  5-  The Card Reader 0 Magnetic Stripe Card  The card can be read either swiped from right to left, or from left to right.  The magnetic track on the card turned on the rear side of the terminal and the card should be swiped through the track reader freely and without hesitation.  0 Micro Chip Card  Introduce the card horizontally into the apparatus, the micro-chip facing up, as indicated and leave the card in position for the length of time that it takes to process the transaction.   6-  Portable Functioning The ELITE 770 terminal is portable ; it includes batteries which permit to make 150 transactions without connection to the base.  A star on the upper right side of the display indicates a correct connection between the terminal and its base.  A battery low is indicated by a message « -BAT- » on the display following by a beep. The terminal continues to run during about 40 transactions, but batteries need to be reloaded during at least 14 hours.  In a portable mode, the ELITE 770 terminal enters in a wait state automatically after 20 seconds of inactivity or after hitting the RED key.  The message « -RANGE- » appears  on the terminal display when the terminal is out of range of the base, during a communication establishment. To work properly, put the terminal nearer the base (about 100 meters in open air, 40 meters inside a building depending on the environment).  The message « -BUSY- » appears during a connection with the base when an other terminal is already in communication with this base. The operator must wait the end of the communication between the base and the other terminal.  The message « -FULL- » appears when the terminal wants to connect a base which already has the right number of terminal. In this case, switch off the base during a few seconds, and launch a profile on each terminal (System menu-
Terminal ELITE 770  10   configuration) of the network. If the problem persists, switch off the base and call your maintenance company.                Before the first use of the terminal, batteries must be loaded during at least 14 hours.
Version May 1999   11  II-  ELITE 770 TECHNICAL OVERVIEW 1-  Terminal feature  The ELITE 770 version has the following features :  • Up to 1Mbyte Battery backed-up  RAM with advanced memory protection • 512 bytes EEPROM • INTEL  compatible 8051 CPU • Battery backed-up  calendar • Buzzer • 18 keys keyboard • Track 2 Card Reader (Optional Track 2 & 3 or 2 & 1) • ISO 7816 Smart Card Reader • 1 RS232 port for an ECR connection or external device connection  • Built-in Modem CCITT V22, V22 bis • Automatic tone dialling facility • Short range radio communication with base • Up to four SIM smart card connectors (Option) • Short range radio base with RS232 serial communication port • LAN facilities on a same base (up to 10 terminals)   2-  Display  The Display is a 2 lines 16 characters  back-light LCD or a large screen graphical display  3-  Printer  The printer includes the following features :  • a paper chamber for housing the paper roll • a cutter, above the printer mechanism, allowing the user to cut manually the receipts  • a push button which activates the Line Feed mechanism and self-test • a speed of 4 lines per second
Terminal ELITE 770  12   4-  RS232 Interface  Logic level  (RS 232C level) :  • logic level « 0 » : -8V   • logic level « 1 »: +8V   • minimum « 0 » level on input : -3V   • minimum « 1 » level on input : +3V   • maximum current : 10 mA  standard interface :  • rate : 300 to 19200 bauds   • format :  7 to 8 bits   • parity: odd, even, none   • interface: V28   5-  RS232 Connection    6   1 1  þþ  N.U 2  þþ  TxCOM1 3  þþ  RxCOM1 4  þþ  CTS 5  þþ  RTS 6  þþ  Ground
Version May 1999   13  6-  Modem  The Modem  fulfils the data exchange function between the system and telephone network. It is a full-duplex asynchronous modem complying with CCITT V22 & V22 bis recommendations. The MODEM is connected (through the base) to the telephone network by a removable cord fitted with a telephone connector which is plugged into the telephone wall socket. It is equipped with :  • A computerised electronics with built-in application program and module self-test • A line interface for connection to the telephone network • An automatic tone dialling facility • A connector for plugging in a removable phone cord, fitted with a 6-contacts connector or adapter plug (depending on the country) 7-  SIM Interfaces  When implemented, access to the optional SIM connectors needs to open the battery door located at the bottom of the terminal.
Terminal ELITE 770  14   0 SIM Installation   • Slide the card holder cover, • Turn over the cover • Insert a SIM card into the card holder, • Shut the cover • Slide the cover to lock   0 SIM Removal  • Slide the card holder cover, • Turn over the cover • Remove SIM card from the card holder, • Shut the cover • Slide the cover to lock  8- Technical Specifications 0 Power Supply.  • Power Input Voltage 115 / 230Vac • Power Input Frequency 50/60Hz • Power Output 10 Vac 500 mA 6 VA               a b c     ∅ 5,5 ∅ 2,5 9,5
Version May 1999   15  0 Terminal  • Dimensions H x D x W 210 x 92 x 68 mm • Operating Temperature +5oC to +40oC • Humidity 20% to 90% No Condensation  0 Radio communication  • Type Half-duplex • Bandwidth ISM 433,9 MHz • Emitting power ≤10 mW (Don’t need license) • Channels 15  (100 kHz between channels) • Range ≈ 100 meters (open air)   ≈ 40 meters (typical)
Terminal ELITE 770  16   III-  PROCEDURES OF INSTALLATION  After having made the connections previously described, the operator can switch the terminal on. Before doing this, the operator is obliged to enter all general data at the terminal level.  1-  Configuring Radio Link  IMPORTANT NOTE : The following configuration is not necessary for a single configuration (one base, one terminal), as it has been carried out during production.  It is necessary only if you attempt to add a terminal on a previously purchased base.  This procedure, if failed, can provoke malfunction of other terminals connected to your base. In case you are not sure to carry it out properly, or if it does not work properly, call your retailer, who has powerful tools to configure both terminals and base. The LAN can not support more than 5 terminals without reconfiguring base. In case you need 6 to 10 terminals on the same base, call your retailer, who is able to configure properly the base.  • The link between the base and the terminals is coded from the related serial numbers. This means that both terminals and base must know the serial number of other components in the LAN.  • The base is able to find terminals identifiers at the first radio connection after power-on. You don’t need to configure it. • The terminal must be configured in order to know the number of the base where it will have to connect. In the menu « INPUT BASE # » under « SYSTEM MENU », validate. The terminal then displays « LAN CONFIG. ». Enter the code 2049, then validate. The terminal displays then the maximum number of terminals. If your base is a ‘standard’ one, enter 5, then validate, else validate without modification. The base’s serial number is then displayed. This number correspond to the number printed on the back of the base. Enter it, followed by the VAL key. • Your terminal is now configured. You can test it by printing a configuration receipt (system menu, configuration), that must indicate the number of terminals and the base serial number.  • In case the message ‘Absent base ! ‘ is printed, the base serial number is not correct. • In case the message « FULL » is displayed, the number of terminals is not correct, or your base don’t support an other terminal.
Version May 1999   17  2-  Entering the Date and the Time  In its dormant state the terminal indicates its version of the date and time.  The date and time modification procedure will not be carried out if the date and time are incorrect.   N° DISPLAY/PRINTING ACTION 1 CARD >>> 21/07/99   18 :32 Press the   key  2 SYSTEM MENU CHANGE DATE TIME Press the GREEN key 3 DATE : 21/07/99 Enter the current date (character « / »  is automatically inserted).  Press the GREEN key 4 TIME : 18 :32 Enter the current time (character «  : »  is automatically inserted). Press the GREEN key 5 CARD >>> 21/07/99   18 :32
Terminal ELITE 770  18   3-  Telephone Network Parameters  With regard to the following points ; if the value already present in the apparatus is correct, the value will be validated without having to enter a new one.   N° DISPLAY/PRINTING ACTION 1 CARD >>> 21/07/99   18 :32 Press the   key and select the function by    or    keys 2 SYSTEM MENU CHANGE PAD PAR. Press the GREEN key 3 SYSTEM MENU SWBOARD = (up to 4 char) The current value is displayed. If necessary, enter the value of the switchboard to connect the terminal to the switch network. Cancel the value with the RED key in the case of a direct line. Press the GREEN key 4 DWNL = 08 36 06 24 24 (up to 12 char) Press the GREEN key 5 CARD >>> 21/07/99   18 :32
Version May 1999   19  4-  Configuration Receipt  This receipt put together the hardware and the software status of the terminal.   N° DISPLAY/PRINTING ACTION 1 CARD >>> 21/07/99   18 :32 Press the   key and select the function by    or    keys 2 SYSTEM MENU CONFIGURATION Press the GREEN key 3 The terminal prints a receipt   4 CARD >>> 21/07/99   18 :32    5-  Option « Table Number »  This function is used in a restaurant environment.   N° DISPLAY/PRINTING ACTION 1 CARD >>> 21/07/99   18 :32 Press the  key and select the function by    or    keys 2 SYSTEM MENU OPTIONS Press the GREEN key 3 ENTER TABLE N. : 0 The current value is displayed. « 1 » means the table number will be requested for each payment 4 CARD >>> 21/07/99   18 :32
Terminal ELITE 770  20   6-  Application Software Downloading Procedure  This function allows the remote downloading of a new software application version. The terminal call the host which contains the new required version of the application.   N° DISPLAY/PRINTING ACTION 1 CARD >>> 21/07/99   18 :32 Press the   key and select the function by   or   keys  2 SYSTEM MENU DOWNLOAD Press the GREEN key 3 DOWNLOAD Confirm  ENTER Press the GREEN key 4 DOWNLOAD Download ? Press the GREEN key 5 DOWNLOAD PABX= ? If necessary , enter the value of the switchboard to connect the terminal to the switch network 6 DOWNLOAD Code = If necessary, enter the header of the host phone number and press the GREEN key 7 DOWNLOAD Tel # Enter the host telephone number and press the GREEN key 8 DOWNLOAD DIALING The terminal attempts to establish a connection to the host. After the connection, four possibilities are offered :  ADD, UPDATE, DELETE and END ( for more explanation refer to the download manual)
Version May 1999   21  IV-  SECURITY RECOMMANDATIONS   0 0 This terminal has no power switch. The power supply is the only device used to switch off the terminal. Of this fact the main power must be easily accessible.  1 Guideline of security concerning the Lithium batteries: • Hold out of reach of the children, • In case of ingestion of battery elements, the person involved should seek medical assistance promptly, • It is important to respect the polarities `+ ' and`-`, • Do not attempt to reactivate the batteries by a heat source, by an electric refill or all other means, • Do not dispose of batteries in fire, • Do not disassemble the batteries   1 Guideline of security concerning the batteries nickel Cadmium: • Hold out of reach of the children • Do not heat or throw to the fire, • Do not short-circuit the batteries, • Do not close up the valves of security (situated under the positive poles), • Do not use in a hermetic box, • Use the adapted charger, only in the range of specified temperature, • Do not manipulate and put back in service if the battery is damaged and/ or if it presents some liquid flights.  1 Of a general manner: • A danger of explosion is possible if there is incorrect replacement of the battery. • Replace the battery with the same equivalent type advise by the constructor. • Put the used batteries to the rubbish accordingly to the instructions of manufacturer.  00  The equipment has been approved in accordance with Council decision 98/482/EC for pan-European single terminal connection to the public switched telephone network (PSTN). However, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point.  In the event of problem, you should contact your equipment supplier in the first instance