Ingenico ELITE770HH Elite 770 Short Range RF User Manual Manual

Ingenico Elite 770 Short Range RF Manual

Contents

Exhibit 22 Elite 770 Users Manual

Download: Ingenico ELITE770HH Elite 770 Short Range RF User Manual Manual
Mirror Download [FCC.gov]Ingenico ELITE770HH Elite 770 Short Range RF User Manual Manual
Document ID106935
Application ID7CBmw7Vtax4RXonNSRGqzw==
Document DescriptionExhibit 22 Elite 770 Users Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.62kB (170225 bits)
Date Submitted2000-06-27 00:00:00
Date Available2000-07-06 00:00:00
Creation Date2000-06-20 13:43:59
Producing SoftwareAcrobat PDFWriter 4.0 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleManual.PDF
Document CreatorMicrosoft Word
Document Author: danhuynh

Version May 1999
ser's Manual
Version May 99
ELITE 770 *
Terminal ELITE 770
INGENICO
9, quai de Dion Bouton
92816 Puteaux cedex
RCS Nanterre B 317 218 758 - SIRET 317 218 758 00033
DIV0510A
Version May 1999
Table of contents
I-
PRESENTATION OF THE TERMINAL
1- Introduction
2- The Terminal
3- The connections
4- The Keyboard - Principles of Utilisation
5- The Card Reader
6- Portable Functioning
II- ELITE 770 TECHNICAL OVERVIEW
11
1- Terminal feature
11
2- Display
11
3- Printer
11
4- RS232 Interface
12
5- RS232 Connection
12
6- Modem
13
7- SIM Interfaces
13
8- Technical Specifications
14
III- PROCEDURES OF INSTALLATION
16
1- Configuring Radio Link
16
2- Entering the Date and the Time
17
3- Telephone Network Parameters
18
Terminal ELITE 770
4- Configuration Receipt
19
5- Option « Table Number »
19
6- Application Software Downloading Procedure
20
IV- SECURITY RECOMMANDATIONS
21
Version May 1999
I-
Presentation of the terminal
1-
Introduction
The ELITE 770 is a portable payment terminal. This terminal was created to process all
payments made by magnetic or smart cards.
The ELITE 770 terminal benefits from a modular conception which permits it to treat all cards of
different types using separate corresponding programs. It is therefore important to understand
the manner in which it functions, at the modular and the terminal level.
0 The Modular Level
These functions link up with and correspond to the many different types of cards that the terminal
processes, the most important of which is the principal function of payment.
0 The Terminal Level
There are a certain number of functions that are the concern of a ‘global treatment’ and not of a
particular module. The terminal level is the superior level and is common to all modules. This
level does not depend on the number or the nature of each module.
In its base version the ELITE 770 terminal is equipped with a module
that permits it to process Bank Cards. Your retailer or installer will be
able to give you all the necessary information on all modules on offer
and their installation details.
Terminal ELITE 770
2-
The Terminal
The terminal case conta ins the following elements :
The portable terminal itself,
• A base.
• The cable that connects the terminal to a telephone line.
• The block sector that connects the terminal to a 115 or 230 volts power point
(depending on the country)
3-
The connections
0 Telephonic Connection
The compact telephonic cable connection
that is supplied with the Elite terminal, must
be introduced into the terminal plug, marked
with the symbol
. The telephone
connection (RJ11) must be introduced into
the telephone socket in the wall.
Telephonic line
0 Electrical Connection
The small jack connection to the block sector
is plugged into the connection marked with
the symbol
on the terminal. The twin
pronged electrical plug of the block is
connected to an electrical point of 115 or
220 volts (depending the country).
Power Supply
0 Connection with an External Peripheral
Certain peripheral devices such as a check
reader can also be connected.
Version May 1999
The ELITE 770 terminal must be powered
off before connecting the cable on the base,
to the RS232 port..
Serial port
Version May 1999
4-
The Keyboard - Principles of Utilisation
• The
key permits the operator to access the corresponding modular level
functions
• The
and
keys permit to access to the terminal level functions and
to the system menu
• The key ↑ permits a paper feed of a couple of centimetres
• The GREEN key permits the validation of any information read by
or entered into the terminal
• The RED key cancels the occurring command after which, it returns
the terminal to the idle state
• The YELLOW key deletes the last character entered, and is used
in certain cases where an override is requested
• The key marked 00 can only be used for entering amounts ;
more particularly it permits the operator to enter amounts i n cents
Version May 1999
5-
The Card Reader
0 Magnetic Stripe Card
The card can be read either swiped from right to left, or from left to right. The magnetic
track on the card turned on the rear side of the terminal and the card should be swiped
through
the
track
reader
freely
and
without
hesitation.
0 Micro Chip Card
Introduce the card horizontally into the apparatus, the micro-chip facing up, as indicated
and leave the card in position for the length of time that it takes to process the
transaction.
6-
Portable Functioning
The ELITE 770 terminal is portable ; it includes batteries which permit to make 150
transactions without connection to the base.
A star on the upper right side of the display indicates a correct connection between the
terminal and its base.
A battery low is indicated by a message « -BAT- » on the display following by a beep.
The terminal continues to run during about 40 transactions, but batteries need to be
reloaded during at least 14 hours.
In a portable mode, the ELITE 770 terminal enters in a wait state automatically after 20
seconds of inactivity or after hitting the RED key.
The message « -RANGE- » appears on the terminal display when the terminal is
out of range of the base, during a communication establishment. To work properly,
put the termina l nearer the base (about 100 meters in open air, 40 meters inside a
building depending on the environment).
The message « -BUSY- » appears during a connection with the base when an
other terminal is already in communication with this base. The operator must wait
the end of the communication between the base and the other terminal.
The message « -FULL- » appears when the terminal wants to connect a base
which already has the right number of terminal. In this case, switch off the base
during a few seconds, and launch a profile on each terminal (System menu-
Terminal ELITE 770
configuration) of the network. If the problem persists, switch off the base and call
your maintenance company.
Before the first use of the terminal, batteries must be
loaded during at least 14 hours.
10
Version May 1999
II-
ELITE 770 TECHNICAL OVERVIEW
1-
Terminal feature
The ELITE 770 version has the following features :
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
2-
Up to 1Mbyte Battery backed-up RAM with advanced memory protection
512 bytes EEPROM
INTEL compatible 8051 CPU
Battery backed-up calendar
Buzzer
18 keys keyboard
Track 2 Card Reader (Optional Track 2 & 3 or 2 & 1)
ISO 7816 Smart Card Reader
1 RS232 port for an ECR connection or external device connection
Built-in Modem CCITT V22, V22 bis
Automatic tone dialling facility
Short range radio communication with base
Up to four SIM smart card connectors (Option)
Short range radio base with RS232 serial communication port
LAN facilities on a same base (up to 10 terminals)
Display
The Display is a 2 lines 16 characters back-light LCD or a large screen graphical
display
3-
Printer
The printer includes the following features :
• a paper chamber for housing the paper roll
• a cutter, above the printer mechanism, allowing the user to cut manually the
receipts
• a push button which activates the Line Feed mechanism and self-test
• a speed of 4 lines per second
11
Terminal ELITE 770
4-
RS232 Interface
Logic level (RS 232C level) :
• logic level « 0 » :
-8V
• logic level « 1 »:
+8V
• minimum « 0 » level on input :
-3V
• minimum « 1 » level on input :
+3V
• maximum current :
10 mA
standard interface :
5-
• rate :
300 to 19200 bauds
• format :
7 to 8 bits
• parity:
odd, even, none
• interface:
V28
RS232 Connection
12
þ
N.U
þ
þ
TxCOM1
RxCOM1
þ
þ
CTS
RTS
þ
Ground
Version May 1999
6-
Modem
The Modem fulfils the data exchange function between the system and telephone
network. It is a full-duplex asynchronous modem complying with CCITT V22 & V22 bis
recommendations.
The MODEM is connected (through the base) to the telephone network by a removable
cord fitted with a telephone connector which is plugged into the telephone wall socket.
It is equipped with :
• A computerised electronics with built-in application program and module
self-test
• A line interface for connection to the telephone network
• An automatic tone dialling facility
• A connector for plugging in a removable phone cord, fitted with a 6-contacts
connector or adapter plug (depending on the country)
7-
SIM Interfaces
When implemented, access to the optional SIM connectors needs to open the battery
door located at the bottom of the terminal.
13
Terminal ELITE 770
0 SIM Installation
•
•
•
•
•
Slide the card holder cover,
Turn over the cover
Insert a SIM card into the card holder,
Shut the cover
Slide the cover to lock
0 SIM Removal
•
•
•
•
•
8-
Slide the card ho lder cover,
Turn over the cover
Remove SIM card from the card holder,
Shut the cover
Slide the cover to lock
Technical Specifications
0 Power Supply.
• Power Input Voltage
• Power Input Frequency
• Power Output
14
115 / 230Vac
50/60Hz
10 Vac 500 mA 6 VA
∅ 5,5
∅ 2,5
9,5
Version May 1999
0 Terminal
• Dimensions H x D x W
• Operating Temperature
• Humidity
210 x 92 x 68 mm
+5oC to +40oC
20% to 90% No Condensation
0 Radio communication
•
•
•
•
•
Type
Bandwidth
Emitting power
Channels
Range
Half-duplex
ISM 433,9 MHz
≤10 mW (Don’t need license)
15 (100 kHz between channels)
≈ 100 meters (open air)
≈ 40 meters (typical)
15
Terminal ELITE 770
III- PROCEDURES OF INSTALLATION
After having made the connections previously described, the operator can switch the
terminal on. Before doing this, the operator is obliged to enter all general data at the
terminal level.
1-
Configuring Radio Link
IMPORTANT NOTE : The following configuration is not necessary for a
single configuration (one base, one terminal), as it has been carried out
during production.
It is necessary only if you attempt to add a terminal on a previously purchased base.
This procedure, if failed, can provoke malfunction of other terminals connected to
your base. In case you are not sure to carry it out properly, or if it does not work
properly, call your retailer, who has powerful tools to configure both terminals and
base.
The LAN can not support more than 5 terminals without reconfiguring base. In case
you need 6 to 10 terminals on the same base, call your retailer, who is able to
configure properly the base.
• The link between the base and the terminals is coded from the related serial
numbers. This means that both terminals and base must know the serial number
of other components in the LAN.
• The base is able to find terminals identifiers at the first radio connection after
power-on. You don’t need to configure it.
• The terminal must be configured in order to know the number of the base where
it will have to connect. In the menu « INPUT BASE # » under « SYSTEM
MENU », validate. The terminal then displays « LAN CONFIG. ». Enter the
code 2049, then validate. The terminal displays then the maximum number of
terminals. If your base is a ‘standard’ one, enter 5, then validate, else validate
without modification. The base’s serial number is then displayed. This number
correspond to the number printed on the back of the base. Enter it, followed by
the VAL key.
• Your terminal is now configured. You can test it by printing a configuration
receipt (system menu, configuration), that must indicate the number of terminals
and the base serial number.
• In case the message ‘Absent base ! ‘ is printed, the base serial number is not
correct.
• In case the message « FULL » is displayed, the number of terminals is no t
correct, or your base don’t support an other terminal.
16
Version May 1999
2-
Entering the Date and the Time
In its dormant state the terminal indicates its version of the date and time. The date and
time modification procedure will not be carried out if the date and time are incorrect.
N°
DISPLAY/PRINTING
CARD >>>
ACTION
Press the
key
21/07/99 18 :32
SYSTEM MENU
Press the GREEN key
CHANGE DATE TIME
DATE : 21/07/99
Enter the current date (character « / »
is automatically inserted).
Press the GREEN key
TIME : 18 :32
Enter the current time (character « : »
is automatically inserted).
Press the GREEN key
CARD >>>
21/07/99 18 :32
17
Terminal ELITE 770
3-
Telephone Network Parameters
With regard to the following points ; if the value already present in the apparatus is
correct, the value will be validated without having to enter a new one.
N°
DISPLAY/PRINTING
CARD >>>
21/07/99 18 :32
SYSTEM MENU
ACTION
Press the
or
keys
key and select the function by
Press the GREEN key
CHANGE PAD PAR.
SYSTEM MENU
(up to 4 char)
The current value is displayed. If necessary,
enter the value of the switchboard to connect the
terminal to the switch network. Cancel the value
with the RED key in the case of a direct line.
Press the GREEN key
DWNL = 08 36 06 24 24
Press the GREEN key
SWBOARD =
(up to 12 char)
CARD >>>
21/07/99 18 :32
18
Version May 1999
4-
Configuration Receipt
This receipt put together the hardware and the software status of the terminal.
N°
DISPLAY/PRINTING
CARD >>>
ACTION
21/07/99 18 :32
Press the
key and select the function by
or
keys
SYSTEM MENU
Press the GREEN key
CONFIGURATION
The terminal prints a receipt
CARD >>>
21/07/99 18 :32
5-
Option « Table Number »
This function is used in a restaurant environment.
N°
DISPLAY/PRINTING
CARD >>>
ACTION
21/07/99 18 :32
Press the
key and select the function by
or
keys
SYSTEM MENU
Press the GREEN key
OPTIONS
ENTER TABLE N. : 0
CARD >>>
The current value is displayed. « 1 » means
the table number will be requested for each
payment
21/07/99 18 :32
19
Terminal ELITE 770
6-
Application Software Downloading Procedure
This function allows the remote downloading of a new software application version. The
terminal call the host which contains the new required version of the application.
N°
DISPLAY/PRINTING
CARD >>>
ACTION
21/07/99 18 :32
Press the
keys
key and select the function by
SYSTEM MENU
Press the GREEN key
or
DOWNLOAD
DOWNLOAD
Press the GREEN key
Confirm ENTER
DOWNLOAD
Press the GREEN key
Download ?
DOWNLOAD
PABX= ?
DOWNLOAD
Code =
DOWNLOAD
Tel #
DOWNLOAD
DIALING
If necessary , enter the value of the switchboard to
connect the terminal to the switch network
If necessary, enter the header of the host phone
number and press the GREEN key
Enter the host telephone number and press the
GREEN key
The terminal attempts to establish a connection to
the host.
After the connection, four possibilities are offered :
ADD, UPDATE, DELETE and END
( for more explanation refer to the download
manual)
20
Version May 1999
IV- SECURITY RECOMMANDATIONS
0 This terminal has no power switch. The power supply is the only device used to
switch off the terminal. Of this fact the main power must be easily accessible.
1 Guideline of security concerning the Lithium batteries:
• Hold out of reach of the children,
• In case of ingestion of battery elements, the person involved should seek medical
assistance promptly,
• It is important to respect the polarities `+ ' and`-`,
• Do not attempt to reactivate the batteries by a heat source, by an electric refill or all
other means,
• Do not dispose of batteries in fire,
• Do not disassemble the batteries
1 Guideline of security concerning the batteries nickel Cadmium:
• Hold out of reach of the children
• Do not heat or throw to the fire,
• Do not short-circuit the batteries,
• Do not close up the valves of security (situated under the positive poles),
• Do not use in a hermetic box,
• Use the adapted charger, only in the range of specified temperature,
• Do not manipulate and put back in service if the battery is damaged and/ or if it presents
some liquid flights.
1 Of a general manner:
• A danger of explosion is possible if there is incorrect replacement of the battery.
• Replace the battery with the same equivalent type advise by the constructor.
• Put the used batteries to the rubbish accordingly to the instructions of manufacturer.
0 The equipment has been approved in accordance with Council decision 98/482/EC for panEuropean single terminal connection to the public switched telephone network (PSTN). However,
the approval does not, of itself, give an unconditional assurance of successful operation on every
PSTN network termination point.
In the event of problem, you should contact your equipment supplier in the first instance
21
ELITE 770 Terminal
22
Version May 1999
23

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 23
Creator                         : Microsoft Word
Create Date                     : 2000:06:20 13:43:59
Title                           : Manual.PDF
Author                          : danhuynh
Producer                        : Acrobat PDFWriter 4.0 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: O34-ELITE770HH

Navigation menu