Innovative Concepts and Design UHF-10BP Body-worn Wireless Microphone User Manual 1
INNOVATIVE CONCEPTS AND DESIGN LLC Body-worn Wireless Microphone 1
15_UHF-10BP UserMan, r1.pdf
UHF-10BP BODY-WORN WIRELESS MICROPHONE Parts Description 1. Low battery Indicator 2. Power indicator 3. Battery Compartment/Cover 4. Antenna 5. Volume control 6. Power ON/OFF Switch 7. MIC input jack 8. Lapel MIC 9. Headset MIC Operation 1. Open battery cover and install 2PCS AA batteries into battery compartment with correct polarity. Then close the battery cover. 2. Insert supplied headset MIC or lapel MIC into MIC IN jack. Turn the metal slip ring on the plug clockwise to thread it on to the jack. 3. Slide power switch to "ON" position to turn on the transmitter. Power indicator will light green. This indicates correct operation. 4. Now receiver RF indicator will light(Please confirm frequency of transmitter same as that of receiver before operation). 5. During operation if low battery indicator lights red, this indicates the battery is Iow. Please replace new battery. 6. After use please slide power switch to “OFF” position to turn off the transmitter. If you are not going to use the wireless microphone system for a long period of time please take out the batteries from the transmitter to avoid possible battery leakage which may damage the transmitter. Specifications Frequency Range: 517.6MHz or 521.5MHz or 533.7MHz or 537.2MHz Frequency Stability: 10ppm RF Output: <10mW Modulation: FM Max Deviation: ±75KHz Spurious Emission: ≥40dB Power Supply: 3V(2xAA batteries) Current Consumption: 100mA NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. the microphones are for professional licensed use under 74.861 only.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 2 Create Date : 2016:06:10 14:24:38+08:00 Modify Date : 2016:06:10 14:24:38+08:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : Administrator Creator : CorelDRAW X6 Title : 未命名 -1EXIF Metadata provided by EXIF.tools