Inomatic MAGIC 8.2MHz EAS System User Manual
Inomatic (Suzhou) Technology Co.,Ltd. 8.2MHz EAS System
Inomatic >
User manual
Universal Mono Standard-Line board UMB 200S Manual Operation Manual RF Standard-Line Mono system (UMB 200S V1.1) Magic 250/350 Helio 250/300 INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual UMB 200S J1 S1 USB RMS V1.1 LED S2 X5 X4 VR2 X3 X2 X1 X8 X1 X2 X3 X4 X5 X8 X9 X9 F1 18VAC power in 18VAC power out Buzzer Relay output (NO) Alarm /Power LED light (12V DC) Antenna loop 1 (8 loop) Antenna loop 2 (88 loop or 0 loop) J1 F1 S2 VR2 S1 Operation/Down- load firmware Fuse 1A Selection switches Buzzer Volume Control Reset processor INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 1. Introduction The Magic/Helio Mono antennas incorporating the UMB 200 Standard-Line Mono electronics is a DOUBLE TRX-loop single panel system that provides enhanced detection as compared to conventional Mono antennas. Multiple Magic/Helio antennas (UMB 200) can operate at the same time without the need of synchronization. The system‘s center frequency is 8.2MHz with frequency “hopping” within a certain frequency band width. This allows good detection of tags even if the center frequency of the tag is not exact 8.2MHz. Advanced APC (Automatic Parameter Control) and ERC (Enhanced Resonance control ) technology is applied to process the transmit and receive signal relative to the environmental noise. This not only benefits the system‘s performance and anti-interference ability but also prevents deactivation of labels near to the antenna. The UMB 200S has a USB interface to download new Firmware if becomes available. The UMB 200S Mono electronics was designed for “PLUG and PLAY” operation Typical performance Magic 350 with UMB 200S performance : 4 x 4 label up to 110 cm on each side Mini square up to 120 cm on each side R 50 hard tag up to 140cm on each side The performance depends on the quality of the label/tag and the orientation of the label/tag INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 2. Functions/Connections 2.1 Alarm Volume Tuning (VR2) The sound level of the alarm buzzer can be adjusted by the potentiometer VR2. Turn VR2 clockwise to increase the volume, counter-clockwise to decrease the volume. 2.2 Down-loading of updated firmware (J1) The firmware can be updated via the computer. When down-loading the firmware J1 has to be the left position. After down-loading set J1 to the right position and press S1 to reset the processor. As the firmware is encrypted please contact our service department for the relevant down-load file. Jumper 1 Normal operation Down-load firmware 2.3 Reset of processor (S1) Pressing the button S1 will reset the processor 2.4 Power/Alarm light connection X5 (active low) ALR LED Note, that if you like to replace the UMB 100 with the UMB 200 the Alarm LED module need to be changed as the UMB 100 Alarm output is 24VDC PW IND LED PWR +12V GND Note, that non-Inomatic LED modules might influence the board performance and/or resulting in higher noise. The maximum current per LED output is 150mA. INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 2.5 Relay output (X4) X4 provides a NO- relay contact output (< 50V DC, 1A). The relay output is activated when the electronics triggers an alarm. 2.6 Power connection (X1 & X2) The power supply (18VAC or 24VDC) is connected to X1. X2 provides an power output of 18VAC or 24VDC depending on the input power supply OUT 18VAC X2 OUT 18VAC IN 18VAC X1 IN 18VAC 2.7 Buzzer connection (X3) The buzzer (12VDC) is to be connected to X3. Please observe polarity (+/-) of the buzzer. 2.8 USB connector (X7) The UMB can be connected to the computer via the USB port for firmware update only 2.9 Antenna loop connections (X8 & X9) The 8 loop of the antenna is connected to X8 (ANT1) and the 88 loop or 0-Loop is connected to X9 (ANT2). If the 0-loop is not used, both ends of the 0-loop are connected to the ground of the board. 2.10 LEDs The LEDs L show the environmental noise level of the system. More LEDs —> more noise INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 2.11 Switch S2 S2 allows the setting of various functions: OFF ON OFF ON Manual Automatic Filter Wide Filter Narrow TX OFF TX ON Gain 3 Gain 2 Gain 1 Gain 0 ON OFF ON OFF ON ON OFF OFF Noise 0 Noise 1 Noise 2 Noise 3 ON OFF ON OFF ON ON OFF OFF ERC OFF ERC ON 8 & 88 loop connected 10 O & 8 loop connected Not in use Default setting: —> all switches in ON position INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 Only in Manual mode www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 3. Installation When installing RF Mono system (UMB 200S) please ensure that there is no RF Swept-system (TX/RX) within 10 meters as Swept-systems influence the performance and can cause false alarms. The swept-system TX generates a continuous 8.2 MHz frequency which negatively affect the noise/ signal ratio and therefore the performance of any Mono antenna. The only alternative is to reduce the Level of the Mono antenna but this will also reduce the performance of the Mono antenna. When multiple Mono antennas are installed, power-up and tune the antennas on by one. After all antennas have been tuned switch on the power to all systems at the same time. The Mono antennas will synchronize automatically once powered-on. The power supply should be installed as close as possible to the Mono antenna. If the 18VAC power line is longer as 5 meter an additional line-filter should be installed. Alarm/Power LED connector X5 “Active low” ALR -> Alarm light GND, 150mA IND -> Power light GND, 150mA PWR -> +12VDC GND -> Ground X1 18VAC /24VDC 1A INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 4. Connection to USB The firmware of the UMB 200S can be updated via the USB port Computer For Firmware update please contact our service department (service@inomatic.com) for the firmware update file. INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 6. Loop connections Default wiring SYSTEM WITH 8 and 0 Loops Please note that for acrylic antennas, the 8 and 88 loop have to be connected jointly to X8. O-Loop 8-Loop Make sure the antenna wires do not run across the board If the switch S2-9 is OFF, the performance of the system increases but it might be more noise sensitive. S2-9 ON X8 X9 X1 18VAC INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice Universal Mono Standard-Line board UMB 200S Manual 6. Loop connections SYSTEM WITH 8 and 88 Loops 88-Loop O-Loop 8-Loop Make sure the antenna wires do not run across the board S2-9 OFF X8 X9 X1 18VAC INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice 10 Universal Mono Standard-Line board UMB 200S Manual 7. Antenna wiring A.) Default wiring of Mono antenna using UMB 200S 0 1 2 0 B.) High Noise environment 13 42 — TRX1 Connect to X9 (0,0) — TRX1 Connect to X9 (3,4) — TRX2 Connect to X8 (1,2) — TRX2 Connect to X8 (1,2) Antenna standard wiring includes 3 loops , 0 loop (0,0), 8 Loop (1,2) and 88 loop (3,4) 13 4 2 If the 0 loop is not used, connect both end of the loop to the GND of the board INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice 11 Universal Mono Standard-Line board UMB 200S Manual 8. REGULATORY COMPLIANCE This equipment complies with European Community regulatory rules for Radio Frequency emissions. It has been awarded with the CE mark. The CE mark is the official marking required by the European Community for all Electric and Electronic equipment that will be sold or put into service for the first time, anywhere in the European community. It proves to the buyer and user that this product meets all essential safety and environmental requirements as they are defined in the “European Directives”. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. INOMATIC (S) PTE LTD 10 Toh Guan Road #03-05 Singapore 608838 Tel: 65-67772958 www.inomatic.com © Inomatic (S) Pte Ltd Version 2017-04 Specifications may change without prior notice 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Create Date : 2017:04:13 16:54:51+08:00 Creator Tool : Microsoft® Publisher 2013 Modify Date : 2017:08:02 17:20:29+08:00 Metadata Date : 2017:08:02 17:20:29+08:00 Producer : Microsoft® Publisher 2013 Format : application/pdf Document ID : uuid:07022ff4-48a2-4772-b05f-6f3b798f223f Instance ID : uuid:9a9be8e9-fcaf-4c74-9e7a-07e7b4d71036 Page Count : 12 Creator : Microsoft® Publisher 2013EXIF Metadata provided by EXIF.tools