Inovonics Wireless 3B6OT9CWP Activity Sensor User Manual 05638B

Inovonics Wireless Corporation Activity Sensor 05638B

manual

1.24.14 05638B © Inovonics, 2014 - www.inovonics.com P/N 7102855 Rev. BEN1240-60 EchoStream® Activity SensorInstallation Instructions1 OverviewThe EN1240-60 activity sensor is designed specifically for residential and senior living environments where a notification of a daily activity is necessary. The EN1240-60 leverages the latest motion detector technology, including white light and pet immunity, to ensure performance accuracy. Selectable fixed sleep intervals of two, four, or six hours are used to minimize wireless traffic in large installations, while confirming daily resident activity. Check-in messages are sent every 60 minutes to provide effective notification of recent resident activity even when the device is in the fixed sleep cycle.Note: For UL 2560 installations, refer to the EN6080 Area Control Gateway Installation Instructions.Note: In UL 2560 installations, transmitters send a check-in message every 60 minutes.Caution: The EN1240-60 needs one minute for stabilization after power up. During the stabilization period, the LED will blink twice per second, and the EN1240-60 will not be operational.Caution: Prior to operation, the EN1240-60 must be acclimated to the temperature of the install environment for a period of 60 minutes.Caution: The EN1240-60 activity sensor is not designed for use as a security system motion detector.1.1 Maximum Number of Repeaters for a UL 2560 InstallationTo achieve the 99.99% alarm message reliability required for UL 2560 compliance, system installations must operate within the following limits for end device and repeater counts.1.2 Inovonics Wireless Contact InformationIf you have any problems with this procedure, contact Inovonics Wireless technical services:• E-mail: support@inovonics.com• Phone: (800) 782-2709; (303) 939-93361.3 EN1240-60 Internal Components Figure 1  EN1240-60 components1.4 What’s In The Carton• Three wall mount screws• Three wall mount anchors• One selection jumper• One 3.0V lithium battery2 Installation and Startup2.1 Installation Notes• These products are designed to be installed and maintained by professional security technicians.• Products are intended for indoor use.• Manually test all products weekly.End Devices Maximum Repeaters150 397250 386350 375500 3601000 3132000 2383000 184AFrequency band selection pins BReset button CPulse count selection pinsDPet immunity selection pins ETest mode reed switch FSleep duration selection pinsGSensitivity adjustment dial HBattery ICase tamper switchJSleep duration selection pins KSleep time selection pinsCADBEGFHIKJ
1.24.14 05638B © Inovonics, 2014 - www.inovonics.com P/N 7102855 Rev. B 22.2 Install/Replace BatteryTo install the battery:1. Release the housing screw and gently raise the cover. Figure 2  Open the cover2. Install the battery in the holder.3. Press the reset button to initialize the transmitter.Note: You must press the reset button each time the battery is changed.2.3 Select the Frequency BandEchoStream products are able to use a range of radio frequencies, and must be configured for your geographic area. This product ships with a default frequency range of 902-928 MHz for use in North America. If you are using the product in North America, skip to section 2.4, “Select Automatic/Pulse Count”; if you are using the product in Australia or New Zealand, you will need to configure the transmitter.4. Place a selection jumper on the appropriate frequency band selection pins.• Place the jumper on the right two pins, marked NZ, to set the frequency range to 921-928 MHz for New Zealand.• Place the jumper on the left two pins, marked AU, to set the frequency range to 915-928 MHz for Australia.5. Press the reset button to complete configuration.Caution: When pressing the reset button, make sure you don’t also touch the frequency band selection pins. Touching the frequency band selection pins while pressing the reset button can inadvertently set the EN1240-60 to the wrong frequency band.2.4 Select Automatic/Pulse CountThe pulse count jumper setting provides control for normal or difficult operating environments. Automatic pulse count is recommended for reliable operation in environments subject to temperature fluctuations that may cause false alarms. The single pulse count mode is more sensitive to minor temperature variations, and should be used in sites where variant heat sources will not cause false alarms.6. Place a selection jumper on the appropriate pulse count selection pins.• Place the jumper on the left two pins, marked AUTO, to select automatic pulse count.• Place the jumper on the right two pins, marked 1 PULSE, to select single pulse count.2.5 Select Fixed/Variable Sleep TimeThe EN1240-60 activity sensor is shipped from the factory set for a fixed sleep time. The fixed/variable sleep time setting should not be changed without specific instruction from Inovonics technical services.2.6 Select Sleep DurationThe EN1240-60 activity sensor is shipped from the factory set for a minimum sleep duration. The sleep duration setting should not be changed without specific instruction from Inovonics technical services.2.7 Select Fixed Sleep TimeAlarm and Check-In MessagesThe EN1240-60 sends two types of message: alarm and check-in. Alarm messages are sent when the EN1240-60 first detects motion. Immediately upon sending an alarm message, the EN1240-60 enters the selected sleep cycle, during which no more alarm messages are sent. Check-in messages are sent by the EN1240-60 every 60 minutes, even during the sleep cycle, to ensure the EN1240-60 is still functional. Check-in messages also include the alarm status as part of the check-in information.Using Sleep CyclesTypically, activity monitoring in senior living environments is performed using a daily time window to confirm resident activity. The EN1240-60 sleep interval can be set to two, four, or six hours. If you require multiple alarms during your daily time window you should select a sleep time shorter than your daily time window.Setting Sleep Cycle DurationTo set sleep cycle duration:7. Place a selection jumper on the appropriate sleep cycle duration selection pins.• Place the jumper on the left two pins, marked 2H, to set the sleep cycle duration to two hours.• Place the jumper on the middle two pins, marked 4H, to set the sleep cycle duration to four hours.• Place the jumper on the right two pins, marked 6H, to set the sleep cycle duration to six hours.Note: Selection jumpers are included in the hardware bag.2.8 Select Pet ImmunityPet immunity allows the EN1240-60 to ignore the movement of small animals.8. Place a selection jumper on the appropriate pet immunity selection pins.• Place the jumper on the left two pins, marked 55lb/25kg to select pet immunity for animals up to 55 pounds (25 kilograms) in weight.• Place the jumper on the right two pins, marked 33lb/15kg to select pet immunity for animals up to 33 pounds (15 kilograms).Note: If neither option is selected, the EN1240-60 will default to the 55lb/25kg selection.2.9 Adjust sensitivityThe sensitivity of the activity sensor can be adjusted to fit your specific application. To adjust sensitivity:9. Use a philip’s head screwdriver to turn the sensitivity adjustment dial.• Turn the dial to the left, towards the minus sign, to decrease the activity sensor’s sensitivity.• Turn the dial to the right, towards the plus sign, to increase the activity sensor’s sensitivity.2.10 Register the TransmitterThe EN1240-60 must be registered with the system receiver in order to be monitored and supervised. Each EN1240-60 has a unique factory-programmed identification number.Note: The transmitter’s unique identification number is the eight digit serial number found on the serial number label.Refer to the receiver installation instructions for details about registering the transmitter.10. When prompted, press the reset button.11. Replace the EN1240-60 cover.12. Replace the housing screw.Caution: The EN1240-60 should be tested after registration to ensure operation. To test the EN1240-60, activate each of the conditions and ensure an appropriate response.Note: The EN1240-60 retains programming data in non-volatile memory. It does not require re-programming after loss of power.2.11 Mount the TransmitterMount the transmitter.13. Remove the EN1240-60 printed circuit board from the housing.14. Use the included hardware to mount the EN1240-60 housing back plate to the mounting surface.Housing screw
1.24.14 05638B © Inovonics, 2014 - www.inovonics.com P/N 7102855 Rev. B 3a. If using the wall tamper function for increased security, mount the housing back plate per Figure 3, ensuring the tamper switch is depressed. Figure 3  EN1240-60 mounting back plateb. If not using the wall tamper, mount the housing back plate using all appropriate hardware.3 Mounting ConsiderationsThe following should be considered when mounting the EN1240-60:• The activity sensor should be mounted such that the expected intrusion motion is perpendicular to the protection zones• The activity sensor may not detect motion behind obstructions, including blinds, curtains, and drapes• The activity sensor should be mounted on a solid, vibration-free mounting surface• Fans and blowers can cause false alarms.• The following may cause false alarms:-  Fans-  Blowers-  Drafts-  Windows-  Heat and cooling sources-  Sunlight-  Animals4 Optional Ceiling/Wall Mount ApplicationThe optional ceiling and wall mount brackets are available separately from Inovonics, part number ACC665.Note: Applications that require the back tamper cannot use the ceiling or wall mount bracket. Figure 4  Ceiling and wall mount bracketsTo mount a ceiling or wall bracket:1. Remove the pcb board.2. Attach the housing to the bracket. Figure 5  Remove the pcb board and attach the housing to the bracket3. Replace the pcb board.5 Test the EN1240-60Caution: The EN1240-60 should be tested after registration, and at least once a year thereafter, to ensure operation. To test the EN1240-60, activate each of the conditions and ensure an appropriate response.5.1 Perform a Walk TestThe walk test is performed to ensure motion is sensed and an RF transmission results. To perform a walk test:1. Swipe a magnet past the reed switch. The five minute walk test will begin; every time motion is sensed, the LED will light.Note: During walk test, the EN1240-60 will not transmit alarms when motion is detected; only the LED will light.2. Walk in front of the activity sensor to test the sensor. 3. After five minutes the walk test will automatically end.6 OperationThe EN1240-60 transmitter signals an alarm condition when motion is detected by the sensor.  Figure 6  Standard mounting height and range7 US Patent Numbers• 7,154,866• 7,554,932• 7,746,804• Other patents pendingMount either corner or wall with screw onlyMount either corner or wall with screw and wall anchorMount either corner or wall with screw onlyCeiling mount Wall mount6’ 10”- 8’ 10”49’
1.24.14 05638B © Inovonics, 2014 - www.inovonics.com P/N 7102855 Rev. B 48 SpecificationsDimensions: 4.5”H x 2.5”Wx 1.6”D (11.4 cm x 6.4 cm x 4.1 cm)Detection method: Quad element PIRStorage temperature: -4° to 140°F (-20° to 60°C)Operating temperature: 32° to 122°F (0° to 50°C), 90% relative humidity, non-condensingHumidity: 0 - 90% (non-condensing)Typical battery life: 2 yearsBattery: 3V LiMnO2, BAT604 (Panasonic CR123A or Duracell DL123A)Power requirement: 3VDC, 60 mATemperature compensation: YesTamper: Housing and wall tamperPIR RF interference immunity: Greater than 30 v/m 26 MHz - 1 GHzStabilization period: one minuteAlarm lockout time: two, four, or six hoursWalk test period: five minutesMounting height: 6’ 10” to 8’ 10” (2.1 to 2.7m)UL certification: UL 2560Compatible receiver for UL 2560 installations: EN6080Compatible repeater for UL 2560 installations: EN5040-20TNote: In a UL 2560 installation, the EN1240-60 may be used with completed emergency call systems for assisted living and independent living facilities.9 Television and Radio InterferenceThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.10 FCC Part 15 and Industry Canada ComplianceThis device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.11 Warranty/DisclaimerCaution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.Inovonics Wireless Corporation ("Inovonics") warrants its EchoStream products ("Product" or "Products") to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of thirty-six (36) months from the date of manufacture. Within the warranty period, Inovonics will repair or replace, at its option, all or any part of the warranted Product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To exercise the warranty, the User ("User", "Installer" or "Consumer") must work directly through their authorized distributor who will be given a Return Material Authorization ("RMA") number by Inovonics. Details of shipment will be arranged directly through the authorized distributor.This warranty is void in cases of improper installation, misuse, failure to follow installation and operating instructions, alteration, accident or tampering, and repair by anyone other than Inovonics.This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express, or implied. There is no warranty by Inovonics that Inovonics product will be merchantable or fit for any particular purpose, nor is there any other warranty, expressed or implied, except as such is expressly set forth herein.  In no event shall Inovonics be liable for an incidental, consequential, indirect, special, or exemplary damages, including but not limited to loss of profit, revenue, or contract, loss of use, cost of down time, or interruption of business, nor any claim made by distributor's customers or any other person or entity.This warranty will not be modified or extended. Inovonics does not authorize any person to act on its behalf to modify or extend this warranty. This warranty will apply only to Inovonics Products. Inovonics will not be liable for any direct, incidental, or consequential damage or loss whatsoever, caused by the malfunction of Product due to products, accessories, or attachments of other manufacturers, including batteries, used in conjunction with Inovonics Products.

Navigation menu