AP669 Ceiling Mount Detector Installation Sheet
Selecting a mounting location
Install the detector so that the expected movement of an
intruder will be across the fields of view. This is the direction
best suited for PIR detectors.
Avoid possible false alarm sources such as:
• Direct sunlight onto the detector
• Heat/cold sources in a field of view (heaters, air
conditioning, radiators, etc.)
• Moving objects in the field of view (fans, pets, etc.)
• Obscuring the detector field of view with large objects,
such as furniture
Caution: Increasing mounting heights beyond the specified
range will reduce sensitivity.
Mounting instructions
Figure 1: Mounting
1. Lift off mounting plate (item 1) as shown in Figure 1.
Fasten the mounting plate to the ceiling in the required
position using mounting holes (item 2).
The detection pattern can be adjusted by up to ±15°
(30° max.) by rotation of the mounting plate prior to
tightening the screws.
2. Strip outer jacket approximately 2 inches (50 mm) and pull
it through the cable entry hole (item 3) and strain relief.
3. Wire the detector and select the appropriate processing
options as shown in Figure 2 and replace the sensor
module (item 6).
4. To mount the sensor module to the mounting plate use the
screw (item 7), which is placed for transport in the
mounting plate.
The curtain directions 1 to 9 clockwise (item 8) are indicated in
the mounting plate (curtain number 5 is the center curtain.)
Connection and programming
Figure 2: Connections and default DIP switch settings
Table 1: DIP switches
Switch
Description
On
Off
1
LED enable
LED on
LED off
2
Processing
Bi-curtain
Standard-4D
3
Detection pattern
180°
360°
Switch 1: Programming the LED
ON: LED enabled.
OFF: LED disabled.
Switch 2: Programming the processing
ON: Enables Bi-curtain processing designed for harsh
environment.
OFF: Provides the standard 4D processing.
Switch 3: Programming the detection pattern
ON: Provides a 180° field of view for special applications.
OFF: Gives the normal 360° field of view.
2 / 2 P/N 14012-EN • REV G • ISS 01NOV16
Note: An arrow in the mounting plate (4) (see Figures 1 and 3)
and inside the sensor module shows the always active
coverage pattern. The coverage pattern opposite to the arrow
can be disabled by setting switch 3 in the ON position.
Figure 3: Coverage pattern
Access to the mirror inside the sensor module
This access is only required when masking individual curtains.
Undo the screw (item 5) and open the sensor module (item 6)
(see Figure 1).
Two mirrors are accessible now.
Selecting the coverage patterns
Mask the appropriate mirror curtains with the adhesive labels
provided and reassemble the sensor module.
For example, see Figure 4 for mirror curtain coverage pattern
corresponding to curtain 4 and 8 masked.
Figure 4: Coverage pattern masking
Mounting height application note
When increased mounting heights are used outside the
specified mounting height range of 8–16 ft. (2.4–4.8 m),
sensitivity will be reduced.
Figure 5: Field of view
Specifications
Input power
12 VDC nom.
Peak to peak ripple
2 V max. (at 12 V)
Current consumption:
Normal operation
9 mA (at 12 V)
Alarm
15 mA max. (at 12 V)
Specified mounting height
8–16 ft. (2.4–4.8 m)
Target speed range
0.9 to 12.0 ft./s
Alarm output
50 mA at 28 V, Form C
Alarm time
2.5 s min.
Tamper output
100 mA at 28 V
Temperature limit
+14 to 131°F (−10 to +55°C)
Relative humidity
93% max.
Size
Ø5.43 in. x 2.68 in. (Ø138 mm x 68 mm)
Weight
4.25 ounces
Number of curtains
18
Max. detection range
60 ft. (18 m) diameter, 30 ft. (9 m) radius
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support