AP669 Ceiling Mount Detector Installation Sheet 1. Selecting a mounting location Install the detector so that the expected movement of an intruder will be across the fields of view. This is the direction best suited for PIR detectors. Lift off mounting plate (item 1) as shown in Figure 1. Fasten the mounting plate to the ceiling in the required position using mounting holes (item 2). The detection pattern can be adjusted by up to ±15° (30° max.) by rotation of the mounting plate prior to tightening the screws. Avoid possible false alarm sources such as: • Direct sunlight onto the detector 2. • Heat/cold sources in a field of view (heaters, air conditioning, radiators, etc.) Strip outer jacket approximately 2 inches (50 mm) and pull it through the cable entry hole (item 3) and strain relief. 3. Wire the detector and select the appropriate processing options as shown in Figure 2 and replace the sensor module (item 6). 4. To mount the sensor module to the mounting plate use the screw (item 7), which is placed for transport in the mounting plate. • Moving objects in the field of view (fans, pets, etc.) • Obscuring the detector field of view with large objects, such as furniture Caution: Increasing mounting heights beyond the specified range will reduce sensitivity. The curtain directions 1 to 9 clockwise (item 8) are indicated in the mounting plate (curtain number 5 is the center curtain.) Mounting instructions Connection and programming Figure 1: Mounting Figure 2: Connections and default DIP switch settings Table 1: DIP switches Switch Description On Off 1 LED enable LED on LED off 2 Processing Bi-curtain Standard-4D 3 Detection pattern 180° 360° Switch 1: Programming the LED ON: LED enabled. OFF: LED disabled. Switch 2: Programming the processing ON: Enables Bi-curtain processing designed for harsh environment. OFF: Provides the standard 4D processing. Switch 3: Programming the detection pattern ON: Provides a 180° field of view for special applications. OFF: Gives the normal 360° field of view. © 2016 UTC Fire & Security Americas Corporation, Inc. 1/2 P/N 14012-EN • REV G • ISS 01NOV16 Note: An arrow in the mounting plate (4) (see Figures 1 and 3) and inside the sensor module shows the always active coverage pattern. The coverage pattern opposite to the arrow can be disabled by setting switch 3 in the ON position. Figure 3: Coverage pattern Mounting height application note When increased mounting heights are used outside the specified mounting height range of 8–16 ft. (2.4–4.8 m), sensitivity will be reduced. Figure 5: Field of view 9 1 8 2 7 3 6 4 5 5 6 4 7 3 8 2 1 An arrow inside the mounting plate & sensor module indicates the always active direction. 9 Shaded area shunted when switch 3 is ON position. Specifications Input power 12 VDC nom. Peak to peak ripple 2 V max. (at 12 V) Current consumption: Normal operation 9 mA (at 12 V) Alarm 15 mA max. (at 12 V) Specified mounting height 8–16 ft. (2.4–4.8 m) Target speed range 0.9 to 12.0 ft./s Alarm output 50 mA at 28 V, Form C Undo the screw (item 5) and open the sensor module (item 6) (see Figure 1). Alarm time 2.5 s min. Tamper output 100 mA at 28 V Two mirrors are accessible now. Temperature limit +14 to 131°F (−10 to +55°C) Relative humidity 93% max. 30 ft. 30 ft. Access to the mirror inside the sensor module This access is only required when masking individual curtains. Selecting the coverage patterns Size Ø5.43 in. x 2.68 in. (Ø138 mm x 68 mm) Mask the appropriate mirror curtains with the adhesive labels provided and reassemble the sensor module. Weight 4.25 ounces Number of curtains 18 For example, see Figure 4 for mirror curtain coverage pattern corresponding to curtain 4 and 8 masked. Max. detection range 60 ft. (18 m) diameter, 30 ft. (9 m) radius Figure 4: Coverage pattern masking Regulatory information Manufacturer UTC Fire & Security Americas Corporation, Inc. 3211 Progress Drive, Lincolnton, NC, 28092, USA Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands Contact information www.utcfireandsecurity.com or www.interlogix.com For customer support, see www.interlogix.com/customersupport 2/2 P/N 14012-EN • REV G • ISS 01NOV16
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 Language : en-US Tagged PDF : Yes Title : AP669 Ceiling Mount Detector Installation Sheet Author : Mikhail Sleptsov Subject : AP669 Ceiling Mount Detector Creator : Microsoft® Word 2010 Create Date : 2016:11:08 10:37:04+01:00 Modify Date : 2016:11:08 10:37:04+01:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools