TECH FACTS BULLETIN
P/N 466-5239 • REV A • 29AUG16

TECHNICAL SUPPORT

TX-4200-01 Supervision using DL900
Introduction
Interlogix is providing this information to instruct dealers on re-configuring alarm panels to
assure that the panels are supervising Panic Devices with part numbers: TX-4200-01-xx.
This bulletin is for users of DL900 software.

Issue
Panic Devices (with part number TX-4200-01-xx) may be enrolled as unsupervised. If that
is the case, failures of the device may go undetected. This procedure will rectify that.
Dealers can re-configure alarm panels to supervise TX-4200 devices.

Procedure
1. Log in to the DL900.
2. Select the account to edit.
3. On the main panel window select “Download”, choose “connect” and choose the
connection path that is available for this panel. Proceed when the panel connection is
established.

P/N 466-5239 • REV A • 29AUG16

© 2016 United Technologies Corporation. All rights reserved

1 of 5

Choose connection path

4. On the main panel window select “Control Panel”
5. Select “Main” a new window will open.
Open Control Panel

6. In the new Control Panel window select the “zones” tab.

P/N 466-5239 • REV A • 29AUG16

© 2016 United Technologies Corporation. All rights reserved

2 of 5

Select Zones tab

7. With the zones displayed click on the Display option and choose “list”.
Select List tab

P/N 466-5239 • REV A • 29AUG16

© 2016 United Technologies Corporation. All rights reserved

3 of 5

8. Look for all zone types 2, 7 and10. These are the most common panic zone types.
(Note if a custom zone type was used for panics, also search for that zone type.).
Write down the zone numbers that met the search criterion.
Choose Zones

9. In the main window select “Expanders”, select “wireless” (or “keypad options” if using
the NX-148E-RF keypad) for the module with the zone that needs to be edited. A new
window will open.
Choose Zone type

P/N 466-5239 • REV A • 29AUG16

© 2016 United Technologies Corporation. All rights reserved

4 of 5

10. Go to the transmitter that corresponds with the zone that needs to be edited.
11. Confirm the ID number starts with a “03” to confirm the device is a panic button.

12. Check the “Supervise” box
13. Select “Send”, and select “send page”. Follow this step for each sensor that needs to
be edited.

14. When complete on the main window choose “Download”, choose “disconnect”
15. Have homeowner test the sensors.
P/N 466-5239 • REV A • 29AUG16

© 2016 United Technologies Corporation. All rights reserved

5 of 5



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 5
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Product: Topic Tech Facts Bulletin
Author                          : CSC
Subject                         : Product: Topic
Keywords                        : TFN
Creator                         : Microsoft® Word 2010
Create Date                     : 2016:08:29 10:52:38-05:00
Modify Date                     : 2016:08:29 10:52:38-05:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools

Navigation menu