Ultrasync Modular Hub Reference Manual
2018-03-05
: Interlogix Ultrasync-Modular-Hub-Reference-Manual ultrasync-modular-hub-reference-manual library
Open the PDF directly: View PDF
.
Page Count: 261
| Download | |
| Open PDF In Browser | View PDF |
Modular Hub Security & Home Automation P/N 466-5261 • REV D * ISS 17NOV17 REFERENCE MANUAL ©2016 United Technologies Corporation About navigating this electronic document: Throughout this document there are navigational links. Wherever you see this symbol ...C... you can click on it to return to the table of contents. Wherever you see this symbol .. I ... you can click on it to return to the index. Wherever you see underlined blue text you can click on it to navigate to that reference. Whenever you navigate to a new page, you can go back using Alt + (left arrow) .... .. PLEASE READ THE IMPORTANT SAFETY AND LEGAL INFORMATION INCLUDING WARNINGS, WARRANTY DISCLAIMERS, AND LIMITATIONS OF LIABILITY BEFORE USING THIS PRODUCT. THIS INFORMATION CAN BE FOUND IN THE PRODUCT WARNINGS AND DISCLAIMERS SECTION BEGINNING ON PAGE 237. 2 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation Contents Welcome .............................................................................................................................. 7 Features & Benefits ........................................................................................................... 7 System Capacity ............................................................................................................... 7 System Components .......................................................................................................... 9 1.1 CPU ...................................................................................................................... 9 1.2 Touch Screen Keypad ........................................................................................ 11 1.3 Zone Expansion Modules ................................................................................... 12 1.4 Relay Expansion Modules .................................................................................. 14 1.5 Wireless Expansion Modules .............................................................................. 16 1.6 Cellular Module ................................................................................................... 17 1.7 Residential Plastic Enclosure.............................................................................. 18 1.8 Commercial Metal Enclosure .............................................................................. 19 1.9 Smart Power Supply ........................................................................................... 20 1.10 Batteries ............................................................................................................. 26 1.11 Transformer ........................................................................................................ 26 2 Hardware Installation..................................................................................................... 27 Minimum System Requirements ..................................................................................... 27 Choose a Location .......................................................................................................... 27 2.1 Power Requirements .......................................................................................... 27 2.2 Grounding ........................................................................................................... 28 2.3 Shielding ............................................................................................................. 28 2.4 Termination Jumpers .......................................................................................... 28 2.5 Cable Requirements ........................................................................................... 28 2.6 Ferrite Installation ............................................................................................... 29 2.7 Wiring Diagram ................................................................................................... 30 2.8 Terminal Diagram ............................................................................................... 32 2.9 LED Diagram ...................................................................................................... 33 3 Programming Methods .................................................................................................. 34 3.1 Programming via Web Server ............................................................................. 35 3.1.1 Connect to LAN .................................................................................................. 35 3.1.2 Retrieve the CPU IP address .............................................................................. 35 3.1.3 Manually Assign an IP Address .......................................................................... 35 3.1.4 Login to the Web Server ..................................................................................... 36 3.1.5 Troubleshooting LAN Connections ..................................................................... 36 3.2 Programming via UltraSync ................................................................................ 36 3.2.1 Set Up a Web Access Passcode for UltraSync................................................... 36 3.2.2 Connect via UltraSync Application ...................................................................... 37 3.2.3 Check LAN Connection to UltraSync Servers ..................................................... 39 3.2.4 Troubleshooting UltraSync Setup ....................................................................... 40 3.3 Programming via DLX 900 Management Software ............................................. 41 3.3.1 Enable Remote Access for DLX 900 .................................................................. 41 3.3.2 Connect using DLX 900 on LAN ......................................................................... 41 3.3.3 Remotely Connect using DLX 900 on UltraSync ................................................ 41 3.4 Programming via On-Site Keypad ...................................................................... 42 3.5 Recommended Items to Change ........................................................................ 42 4 The UltraSync App ......................................................................................................... 44 4.1 Install UltraSync App .......................................................................................... 44 3 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation 4.1 4.2 Using the App ..................................................................................................... 45 UltraSync Color Codes ....................................................................................... 48 5 System Settings ............................................................................................................. 50 5.1 Learn in Sensors................................................................................................. 50 5.2 Learn in a Keyfob................................................................................................ 55 5.3 Programming Areas ............................................................................................ 58 5.4 Programming the System ................................................................................... 61 5.5 Programming Reporting and Notifications .......................................................... 64 5.6 Programming the Network .................................................................................. 66 5.7 Programming Automations (Scenes) .................................................................. 69 5.8 Programming Schedules .................................................................................... 72 5.9 Programming Holidays ....................................................................................... 74 5.10 Lock PIN Share................................................................................................... 76 5.11 Programming Cameras ....................................................................................... 77 Add a Camera Method 1 – Automatic Discovery.......................................................... 77 Viewing Cameras in UltraSync ..................................................................................... 77 5.12 Check Event History ........................................................................................... 78 5.13 Check Connection Status ................................................................................... 79 5.14 Check Details...................................................................................................... 79 6 Advanced Programming Using Web Server ................................................................ 80 6.1 Advanced Programming, System ....................................................................... 82 6.2 Advanced Programming, Sensors ...................................................................... 93 6.3 Advanced Programming, Areas .......................................................................... 97 Notes on Force Arming, Bypass, and Auto-Bypass ................................................... 101 6.4 Advanced Programming, Reporting and Notifications ...................................... 108 Configure Email Reporting ......................................................................................... 111 6.5 Advanced Programming, Communicator .......................................................... 112 6.6 Advanced Programming, Schedules ................................................................. 121 6.7 Advanced Programming, Actions...................................................................... 123 6.8 Advanced Programming, Auto Arm-Disarm ...................................................... 128 6.9 Advanced Programming, Devices and Enrollment ............................................ 130 6.9.1 System Devices ............................................................................................... 130 6.9.1.1 Control Devices ............................................................................................. 131 6.9.1.1.1 Control Outputs .......................................................................................... 132 6.9.1.1.2 Enrollment .................................................................................................. 135 6.9.1.2 Keypads ........................................................................................................ 138 6.9.1.3 Zone and Wireless Expansion Modules ........................................................ 141 6.9.1.4 Relay Expansion Modules ............................................................................. 142 6.9.1.5 Power Supplies ............................................................................................. 144 6.9.2 Interlogix Transmitters ...................................................................................... 144 6.9.3 Z-Wave Devices ............................................................................................... 145 6.9.4 Tablet Keypads ................................................................................................. 145 6.10 Advanced Programming, Permissions .............................................................. 146 6.11 Advanced Programming, Area Groups ............................................................. 150 6.12 Advanced Programming, Menus....................................................................... 151 6.13 Advanced Programming, Holidays .................................................................... 152 6.14 Advanced Programming, Sensor Types ........................................................... 153 Sensor Types Table ................................................................................................... 156 6.15 Advanced Programming, Sensor Options ......................................................... 157 Sensor Options Table ................................................................................................ 160 6.16 Advanced Programming, Event Lists ................................................................ 161 4 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation 6.17 Advanced Programming, Channel Groups ....................................................... 162 Customize Reporting Codes ...................................................................................... 164 Reporting Fixed Codes in Contact I.D. ....................................................................... 166 6.18 Advanced Programming, Action Groups ........................................................... 167 6.19 Advanced Programming, Scenes ..................................................................... 167 6.20 Advanced Programming, Speech Tokens ........................................................ 169 6.21 Advanced Programming, Cameras ................................................................... 169 Add a Camera Method 2 – Manual Entry ................................................................... 169 Removing a Camera .................................................................................................. 169 6.22 Advanced Programming, Network Servers ....................................................... 170 7 Users and Permissions ............................................................................................... 172 7.1 Add Users ......................................................................................................... 172 7.2 Users Submenus .............................................................................................. 174 7.3 Permissions ...................................................................................................... 175 8 Expansion Module Installation ................................................................................... 178 9 Cellular Radio Setup .................................................................................................... 180 9.1 Install Optional Cellular Radio........................................................................... 180 9.2 Check Signal Strength ...................................................................................... 182 9.3 Check cellular connection to UltraSync servers ................................................ 184 10 UltraSync Touchscreen Setup .................................................................................. 186 10.1 Quick Setup ...................................................................................................... 186 10.2 Set up Wi Fi ...................................................................................................... 187 10.3 Enroll the Touchscreen ..................................................................................... 188 10.4 Touchscreen Settings ....................................................................................... 189 10.5 Mounting ........................................................................................................... 189 10.6 Upgrading Firmware ......................................................................................... 190 10.7 Other................................................................................................................. 190 11 Camera Setup Instructions ....................................................................................... 192 11.1 Quick Setup ...................................................................................................... 192 11.2 Setting up Ethernet/Wi Fi transmission ............................................................. 192 11.3 Wi Fi Signal Strength ........................................................................................ 193 11.4 Add Camera via Wi Fi for iOS Device ............................................................... 194 11.5 Add Camera via Wi Fi for Windows PC ............................................................ 194 11.6 Add Camera via Ethernet for iOS Device (non DHCP) ..................................... 195 11.7 Add Camera via Ethernet for Windows PC (non DHCP) .................................. 196 11.8 Add Camera via Ethernet (DHCP) .................................................................... 196 11.9 Add Camera to UltraSync ................................................................................. 196 11.10 View Live Stream and Latest Clip ..................................................................... 198 11.11 Program Event Triggered Camera Clips ........................................................... 198 11.12 View event triggered clips in History ................................................................. 200 11.13 Remove Camera from UltraSync (if needed) .................................................... 200 11.14 Change Default Camera Settings (Via TruVision Navigator) ............................ 200 11.15 Camera Troubleshooting .................................................................................. 201 12 Arming and Disarming the System .......................................................................... 202 12.1 Keypress Tamper ............................................................................................. 202 12.2 Arm Your System in Away Mode ...................................................................... 202 12.3 Arm Your System in Stay Mode ........................................................................ 202 12.4 Disarm One or More Areas ............................................................................... 203 12.5 Activate SOS Feature ....................................................................................... 203 5 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation 13 Glossary ..................................................................................................................... 204 Appendices ..................................................................................................................... 208 A.1 DLX 900 Software............................................................................................. 208 A.2 Troubleshooting DLX 900 ................................................................................. 210 A.3 Firmware Upgrade using DLX 900.................................................................... 211 A.4 Voice Library ..................................................................................................... 212 A.5 System Status Messages ................................................................................. 213 A.6 App and Web Error Messages .......................................................................... 214 A.7 Z-Wave Messages ............................................................................................ 215 A.8 History Events................................................................................................... 216 A.9 Event Reporting Class Table ............................................................................ 218 A.10 Action Events: Category and Types.................................................................. 219 A.11 Action Results Category and Action Results Event Types ................................ 220 A.12 System Building Blocks .................................................................................... 221 A.13 System Menu Tree ........................................................................................... 223 A.14 Calculating Maximum Bus Cable Length .......................................................... 224 A.15 Z-Wave Home Automation Hub ........................................................................ 229 Adding Z-Wave Devices ............................................................................................. 229 Programming Z-Wave Siren ....................................................................................... 231 Removing Z-Wave Devices ........................................................................................ 232 Adding UltraSync Modular Hub to existing Z-Wave network as Secondary Controller233 Removing UltraSync Modular Hub from existing Z-Wave network as Secondary Controller ................................................................................................................... 234 Adding UltraSync Modular Hub to existing Z-Wave network as Primary Controller ... 235 Relinquish Primary Control of UltraSync Modular Hub to another Controller ............. 236 Replacing a Failed Node ............................................................................................ 237 Removing a Failed Node ............................................................................................ 238 Send User PINs to Z-Wave Door Lock....................................................................... 238 UltraSync + app and Web Server Error Messages .................................................... 240 Specifications ................................................................................................................. 241 S.1 CPU Power Input Specifications ....................................................................... 241 S.2 System General Features ................................................................................. 241 S.3 Current Consumption* ...................................................................................... 242 S.4 Battery Capacity Calculations ........................................................................... 243 S.5 Environmental ................................................................................................... 244 S.6 Physical Dimensions......................................................................................... 244 S.7 Fuses ................................................................................................................ 244 S.8 Maintenance ..................................................................................................... 244 S.9 System Monitoring ............................................................................................ 244 S.10 SIA and CID Reporting Code Descriptions ....................................................... 245 UL Specification .............................................................................................................. 250 Product Warnings ........................................................................................................... 256 Warranty Disclaimers .................................................................................................... 257 Disclaimer ..................................................................................................................... 257 Intended Use ................................................................................................................. 257 Copyright ....................................................................................................................... 257 Trademarks and Patents ............................................................................................... 257 Manufacturer ................................................................................................................. 258 Contact Information ....................................................................................................... 258 Customer Support ......................................................................................................... 258 6 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation Certification ................................................................................................................... 258 Advisory messages ....................................................................................................... 258 Regulatory Notices ........................................................................................................ 259 Index Click on entries to navigate .......................................... 260 UltraSync Modular Hub REFERENCE GUIDE Welcome Please read through this document before starting the installation. Features & Benefits With the ability to protect up to 500 zones, 96 areas and 256 users, the system can scale to meet requirements from small homes and businesses, even in demanding installations. The system can be fully customized to meet the needs of virtually any scenario. System Capacity 7 500 Zones 96 Areas 64 Keyfobs 64 Expansion Modules 192 Wireless Sensors 256 Users 128 User Permissions P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation ...C... 8 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 1 System Components 1.1 CPU The CPU is the core component of the system and is the building block of every installation. There are eight on-board hardwired zones that can be zone doubled to 16. Alarm reporting and interactive services are supported by on board Ethernet connectivity. An optional cellular module is available to provide a cellular failover path in the event of a failure of the Ethernet connection. Additionally, a PSTN connection is available for alarm reporting. The default reporting path is over the Ethernet connection and PSTN reporting is disabled by default. ...C... 9 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. There are five on-board outputs supporting siren/speaker/strobe and smoke detector functionality. All are programmable via Actions. Additional capacity and functionality can be added to the system with the addition of expansion modules via the encrypted RS-485 communication bus. Available expansion modules include keypads, hardwired zones, wireless sensors and relay devices. The overall sensor capacity is a combination of hardwired and wireless sensors. Wireless sensor capacity is limited to 192. Keyfob capacity is 64 and is not affected by the number of wireless sensors that are learned into the system. There are multiple ways to configure the system: • A built in web server is available for simple web browser configuration — Local and remote access is supported • UltraSync™ application for Android and Apple devices • DLX 900 Upload/Download software — Local and remote access is supported • UM-1820E touch screen keypad ...C... 10 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.2 Touch Screen Keypad The UM-1820E touch screen keypad is the primary on-premise user interface. It has an intuitive user interface that allows the installer to fully configure the system. It also allows end users to interact with the security system based on their assigned permission level. ...C... 11 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.3 Zone Expansion Modules Hardwired zone capacity of the system can be augmented using zone expansion modules. Eight and 20 zone versions are available. Flexible programming options allow the installer to maximize the efficiency of the zone expansion modules so the entire system capacity can be utilized. For example, if only five zones are hardwired to a zone expansion module, the system can be configured to only utilize those five zones from the module, leaving the remaining unused zones available for the system. ...C... 12 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1 2 3 1. Tamper input. Disabled by default. Connect tamper switch when mounted in a separate enclosure from CPU. Enable in \Devices\System Devices\Relay Expanders\Expander Options. 2. Neg, Aux, not used 3. Enroll button 4. Termination jumper 5. Power available on terminals for sensors. 4 4 5 20 Zone Expander Each zone expansion module must have its Zone Start and End programmed. To operate as a smoke detector reset, see Expander Options. For details on enrolling Zone Expanders see Enroll Function in Advanced Programming, Devices and Enrollment. ...C... 13 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.4 Relay Expansion Modules Hardwired relay output capability can be added to the system using relay expansion modules. Versions are available with 4 and 10relays. Single Pole Double Throw (SPDT) Form C relays can be configured in 3 different modes to support different applications. Flexible programming options allow the installer to setup manual control or automatically control the relays. Relays can be controlled based on events including but not limited to panel state, events (alarms, tamper, and trouble), low battery, AC, Cellular or Ethernet failure. Each output module adds 32 more actions to the system. Seven output modules will provide a maximum of 256 actions. ...C... 14 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1 2 3 1. Tamper input. Disabled by default. Connect tamper switch when mounted in a separate enclosure from CPU. Enable in \Devices\System Devices\Relay Expanders\Expander Options. 2. Bus jumper Not installed – Relay Auxin comes from Auxin terminal. Installed – Relay Auxin is connected to LAN (bus) POS terminal. 3. Manual enroll button 4. Termination jumper 4 4 10 Relay Expander For details on enrolling Relay Output Expansion Modules, see Enroll Function in Advanced Programming, Devices and Enrollment. Three switching modes are available on these relays; Dry Contact and Negative or Positive switching. For details see the relay installation sheet. ...C... 15 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.5 Wireless Expansion Modules Wireless sensor capability of the system is added via the wireless sensor expansion module. In addition to providing wireless sensor capability to the system, the wireless expansion module also can provide support for two hardwired zones and one relay. Up to192 wireless sensors and 64 keyfobs are supported. Multiple wireless sensor expansion modules can be enrolled into the system to improve wireless reception performance; however, the overall wireless sensor capacity is not increased. Each sensor is learned into the CPU, not the module, greatly simplifying the installation process and improving overall system performance when multiple wireless expansion modules are installed: • With two wireless expansion modules installed in close proximity to each other, redundancy is automatically built into the system (e.g. if one wireless receiver fails, the other will continue to receive wireless sensor transmissions). • If a large coverage area is desired, multiple wireless expansion modules can be distributed throughout the area for expanded coverage purposes. Wireless sensors will be received by multiple wireless expansion modules, providing a receive “diversity” benefit in a changing wireless environment. The CPU will process all sensor transmissions received from each wireless expansion module providing wireless sensors multiple reception paths to improve reliability and performance. ...C... 16 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.6 Cellular Module An optional cellular radio module provides a backup communication path over a cellular network if the Ethernet or PSTN connection fails. This provides a plug and play connection with no configuration needed in most cases. The only requirement is good cellular reception. To connect via cellular service, you only need to install the cellular radio module and provision the panel for cellular service grade reporting in the UltraSync portal. For details see the cellular module installation sheet. Note: The cellular module is not a bus connected device. It installs directly to the CPU. Caution: Electrostatic discharge may cause damage and void the warranty. Proper ESD precautions must be used during installation. Remove all power (AC and battery) to the CPU before proceeding. Failing to do so could result in possible damage to the product. System components should be kept in the antistatic packaging when not in use. ...C... 17 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.7 Residential Plastic Enclosure The plastic enclosure features a DIN rail for mounting modules, a tamper switch, and integrated cable management. The lid can be removed by releasing the two screws using the supplied Allen key. The enclosure should be installed indoors under the following operating conditions: • Temperature range: +14°F to 131°F (-10 to +55°C) • Humidity range: Average 95% relative humidity, non-condensing ...C... 18 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.8 Commercial Metal Enclosure A metal enclosure is available for commercial applications, installations where additional zone and/or output expansion modules are required or situations where a larger backup battery is required. The UM-CME metal enclosure includes a tamper switch and two metal DIN rails. The enclosure should be installed indoors under the following operating conditions: • Temperature range: +14°F to 131°F (-10 to +55°C) • Humidity range: Average 95% relative humidity, non-condensing ...C... 19 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.9 Smart Power Supply The UM-SPS smart power supply provides additional battery and current capacity to UltraSync Modular Hub installations. The smart power supply also offers two zone inputs and two programmable SPDT relay outputs. The module has a tamper connector that can be used to supervise the enclosure in which it is mounted. Both the main power input and batteries are monitored. The module provides the option to extend the RS-485 bus length up to an additional 2,600 ft. (800m). The extended RS-485 bus is optically isolated in this configuration. Up to 8 smart power supplies can be used per system. One smart power supply can be used on each bus segment in a star configuration. The UM-SPS does not support a cascaded architecture of multiple units in a daisy chain configuration. Power Outputs The smart power supply has three auxiliary power outputs to power three separate bus segments. The available current on each output is determined by the number of batteries that are connected to the unit. See below for details. ...C... 20 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Battery Connection 1. The smart power supply supports one or two battery configurations. If additional battery backup capacity is required, a second battery can be installed. Up to two 17.2 AH batteries can be connected to the unit. 2. Install batteries before connecting power. 3. Connect a single battery to the Battery 1 input. 4. If a second battery is required, connect it to the Battery 2 input. Battery 2 becomes enabled once the battery test passes. A battery test will occur when power is connected to the smart power supply, daily battery test, or when a user manually activates a battery test. See keypad manual for instructions on performing a manual battery test. Connect Transformer and Tamper 1. A 16.5 VAC/40 VA transformer (recommended Interlogix PN 600-1023 or 600-1023-CN) must be utilized with the unit. Connect the transformer secondary voltage (16.5 – 18.0 VAC) to the smart power supply AC/DC IN connection. 2. If enclosure tamper monitoring is required, connect the tamper switch of the housing to the TAMPER input. You must enable tamper monitoring on the smart power supply in the device expander options menu (tamper monitoring is disabled by default). Over Current Protection The smart power supply provides over current monitoring and protection. When more current is drawn from the power supply than the transformer can provide, the device will send an “Over Current” message to the Modular Hub CPU. The transformer is disconnected within 10 seconds of the over current condition event. Operation continues on battery supply until the condition is removed, or batteries are exhausted. LAN Wiring and Topology The UM-SPS smart power supply can be used as power supply unit or as a bus extension/isolator. Depending in which mode the unit is applied in the field, a different RS485 LAN wiring is required. In power supply mode (option 1), only the LAN connection terminal on the bottom board of the UM-SPS is used. Wire this terminal to the Modular Hub CPU. See diagram Wiring Option 1. In bus extension/isolator mode (option 2), the xGen panel LAN needs to be wired to the ISOLATED LAN terminal on the top board of the UM-SPS. Any bus device wired to the LAN connection terminal on the bottom board is now optically isolated. See diagram Wiring Option 2. ...C... 21 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option 1 – Power supply mode, no bus isolation This option provides additional power to connect more devices. 1. Connect a 40 VA 16.5 VAC transformer to the smart power supply. 2. DO NOT connect CPU POS to the Smart Power Supply POS 1 terminal. 3. Connect the CPU NEG, LAN+ and LAN- to the UM-SPS smart power supply’s NEG, LAN+ and LAN- terminal located on the bottom board. This provides data communication and a common ground. 4. Use POS1/NEG, COM2/POS2 and COM3/POS3 to power additional devices. 5. DO NOT use the ISOLATED LAN terminal located on the top board (POS B, NEG B, LAN B+, and LAN B-). 6. In this configuration, multiple smart power supplies can be cascaded to form a long daisy chain configuration. 7. It is recommended to utilize this configuration when multiple smart power supplies need to be cascaded to form a long daisy chain topology. ...C... 22 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option 2 – Extension/isolator mode For larger sites requiring longer cable runs and/or more power, up to eight UM-SPS smart power supplies can be added. This topology provides additional power and an optically isolated LAN bus between the Modular Hub CPU and each UM-SPS smart power supply. This is useful for connecting the bus between buildings which may require electrical isolation and/or optical isolation to avoid ground loops. 1. Connect the CPU terminals POS, NEG, LAN+ and LAN- to the Smart Power Supply ISOLATED LAN terminal POS B, NEG B, LAN B+, and LAN B-, located on the top board. The CPU will power the smart power supply's isolated LAN B+ and LAN B- terminals. 2. Do not connect the EARTH terminal on the Smart Power Supply to EARTH terminal on the CPU if you require electrical isolation. Follow the guidelines contained in Section 2.2 for connecting the EARTH ground terminal. 3. Use POS1/NEG, COM2/POS2 and COM3/POS3 to power additional devices. 4. USE LAN + and LAN – to connect additional devices on the isolated bus. 5. In this configuration, multiple smart power supplies can NOT be cascaded to form a long daisy chain configuration. 6. It is recommended to utilize the optical isolation mode in most situations as it also isolates bus noise generated on one bus segment from transferring to other bus segments. 7. See below for typical topology in this configuration. ...C... 23 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Connect Relay Outputs Two relay outputs are available on the smart power supply which can be programmed to activate when certain actions occur on the system. See how to program power supplies in Advanced Programming, System Devices Section 6.9.1.5. ...C... 24 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Relay Modes The two Single Pole Double Throw (SPDT) Form C relays can be configured in 3 different modes to support different applications. The relays are connected to the output terminals with Normally Open and Normally Closed connections for your convenience. Use the jumper next to the relay to select the mode suitable to your requirements. Default is no jumper with relay in NC position. Red LEDs light up when the respective relay is energized. No Jumper Dry contact closure provided to output terminal. Maximum Load 30 VAC @ 0.5 A or 24 VDC @ 1 A. Jumper between C and COM2 Smart power supply common connection provided to output terminal @ typical 0 V. Do not exceed relay rating which is maximum load 30 VAC @ 0.5 A or 24 VDC @ 1 A. Jumper between POS2 and C Smart power supply voltage provided to output terminal @ typical 12-13 VDC. Do not exceed relay rating. ...C... 25 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1.10 Batteries A lead acid rechargeable battery must be installed in the system to provide power in the event of main AC power failure. Several options are available as detailed in the table below. Select the appropriate battery based on your system configuration and required battery backup time. See specification section S.4 for battery backup calculation details. Maximum battery capacity connected to the CPU is 12 Amp Hours. Battery Options Part Number Capacity 60-681 4 Amp Hours 60-680 7 Amp Hours Warning: Make sure batteries are stored and worked on in a well ventilated area. ALWAYS wear approved safety glasses and face shield or splash proof goggles when working on or near batteries: Always wear proper eye, face and hand protection. Keep all sparks, flames and cigarettes away from the battery. Never try to open a battery with non-removable vents. Make sure work area is well ventilated. Exercise caution when working with metallic tools or conductors to prevent short circuits and sparks. Always read and follow all precautionary labels on the product. 1.11 Transformer A 16.5 VAC transformer is used to power the system. Select the appropriate transformer from the options shown in the table below. Transformer Options ...C... 26 Part Number Description 600-1023 Class 2 Transformer, 16.5V, 40VA 600-1023-CN Class 2 Transformer, 16.5V, 40VA (Canada) P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 2 2 Hardware Installation Minimum System Requirements CPU Enclosure Power Supply/Transformer Keypad Siren/Speaker Battery Choose a Location When choosing a location for the system components, there are a number of appliances and areas to avoid which could interfere with the system. Choose a location that optimizes signal strength (319.5, Z-Wave, Cellular) Avoid TV and other electronic appliances Avoid microwave ovens Avoid wet and moist areas such as bathrooms and kitchens Avoid cordless telephones Avoid computers and other wireless equipment Do not run bus wiring any closer than 6 inches to an AC or other communication lines. When crossing other lines, always run perpendicular 2.1 Power Requirements The UltraSync Modular Hub is designed to be used with a 16.5 VAC transformer. Alternatively, an 18-26 VDC source can be utilized to power the system. ...C... 27 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 2.2 Grounding The CPU’s Earth terminal must be earth grounded for lightning protection to work effectively. The terminal should be tied to a verified cold water pipe or a dedicated, grounded copper rod 6’ to 10’ long. Use 16 gauge wire. 2.3 Shielding If shielded cable is used, the shielding of all cables should only be connected on one end of the cable to one common grounding point in a building. If a shielded LAN cable is routed via more than one plastic device, the shielding from incoming and outgoing cables must be connected (e.g. multiple plastic enclosures that are daisy chained together). 2.4 Termination Jumpers Correct RS-485 termination reduces communication issues with signal reflections. For a single long cable run, put a jumper across the terminal labeled TERM on the CPU and the furthest bus device. For installations with multiple long cable runs, (star configurations) do not place a terminator on the CPU; rather place one at the end of each of the two longest cable runs. Where the keypad is the last bus device, use the terminal labeled S202. 2.5 Cable Requirements The system’s RS-485 communication bus is used to connect keypads and other devices to the CPU. • 2 pair twisted, 22 AWG cable is recommended. Minimum 4 twists per foot Less than 16 pF per foot Characteristic impedance of 100 to 120 ohms The system’s screw terminals support 30-16 AWG wire The individual wires comprising the twisted pair must be connected to the LAN+ and LANterminals to receive the noise immunity benefits of twisted pair cable. See figure below. Do not combine the individual wires of the twisted pair to increase the effective wire gauge of the cable run. ...C... 28 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. • Maximum RS-485 bus length is 2,600 ft. (800 m) when run as a single serial cable run. If a star configuration is utilized, the maximum total bus length may be reduced substantially depending on the number of branches, the length of the branches and a multitude of other factors. It is recommended to reduce the number of branches and the cable length when utilizing a star configuration. • Device maximum: 64 bus devices. • A separate power supply may be required for long cable runs with multiple devices due to voltage drop on the bus wire. If a device is powered with a separate power supply, do not connect “POS” from the CPU. Connect “+” of the local power supply to “POS” on the device, and connect 0 volts from the power supply and NEG from the CPU to the keypad terminal marked “NEG−”. See Appendix A.14 Calculating Maximum Bus Cable Length, for more details on determining when an additional power supply is required. 2.6 Ferrite Installation Install the supplied ferrite on the Ethernet cable before attaching the cable to the intrusion panel. ...C... 29 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 2.7 Wiring Diagram ...C... 30 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. ...C... 31 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 2.8 • J1 • J6 • S1 • J7 • J10 • J13 • J18 • J20 • J21 • • • • • • • J3 J4 J8 J11 J15 J17 J19 ...C... 32 Terminal Diagram – Terminals for power inputs – Box Tamper (disabled by default) – Enrollment button: Hold button down for 3s to activate automatic device enrollment feature; Holding the button down while powering up resets the Installer user type to a Master Installer user type. – Terminals for Tamper 2 (disabled by default), Output 1 (Siren) and Output 2 (Strobe) – Terminals for Output 3 (Siren) and Output 4 (2 and 4 wire smoke) – RJ45 socket for Ethernet (IP/LAN) connection – Terminals for telephone line, bridged to J20 – RJ11 6P4C socket for telephone line, bridged to J18 output. This connector is accessible after removing the plastic cover on the top of the CPU housing. – 5-pin connector for USBUP device. This connector is accessible after removing the plastic cover on the side of the CPU housing. USBUP device can be used to update firmware or CPU configuration. – Terminals for backup battery – Terminals for RS-485 bus and auxiliary power connection – Terminals for future use – Terminals for Zone 1 and 2 – Terminals for Zone 3 and 4 – Terminals for Zone 5 and 6 – Terminals for Zone 7 and 8. Common terminal shared with output 5 (output 5 disabled by default) P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 2.9 LED Diagram • D3 – Red LED: 5 V internal power present • D5 – Red LED: • Enrollment mode active, slow flash means Automatic enrollment, fast flash means Manual enrollment • During a default it will toggle during each menu default • When communicating over the phone line it will turn on when a valid handshake tone or kiss off tone is present • During a phone session it will turn on when a DTMF digit is detected • D10 – Red LED: follows Output 1 (BELL output), typically used for indoor speaker • D11 – Red LED: follows Output 2 (Strobe) • D12 – Red LED: follows Output 3 (Outdoor Siren) • D13 – Red LED: follows Output 4 (Power) • D14 – Red LED: Ethernet Link Present • D15 – Green LED: Ethernet Activity • D16 – Green LED: UltraSync Ethernet Link Present • D17 – Green LED: UltraSync Cellular Link Present • D18 – Red LED: Heartbeat, should flash every second • D6 – Red LED: RS485 Transmitting • D9 – Green LED: RS485 Receiving • D20 – Red LED: follows Output 5 (Power) ...C... 33 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 3 3 Programming Methods Once your hardware has been installed, there are four (4) ways to program your system. 1) Onboard Web Server 2) UltraSync Application 3) DLX 900 4) On-site keypad Programming includes such tasks as enrolling bus devices, configuring the operation of the security system, adding IP cameras and Z-Wave devices. It is required to first have a UM-1820E touchscreen keypad enrolled in the system before proceeding. Before any bus devices are connected to the CPU, connect a single UM-1820E to the bus and power up the system. To automatically enroll the keypad, push the ENROLL button on the CPU until the LED begins to flash indicating that the automatic enrollment process has been initiated. On Board Web Server – The recommended method, this allows access to all programming menus from the built-in web server using a PC or smart device without the need to install any software. Local and remote access is supported. Remote access requires UltraSync Portal login credentials. Before you can utilize the local method, you will be required to retrieve the IP address of the CPU. Please see Section 3.1.2 of this document for retrieving the IP address. UltraSync App – This provides access to the Hub via a smart device running the UltraSync application. The screens and menus in the UltraSync application are similar to the Web Server screens. Before you can utilize the UltraSync App, you will have to enable this functionality in the CPU by programming the Web Access Passcode. This can be accomplish via the UM-1820E touch screen keypad or the on board web server. Please see Section 3.2 for additional details. DLX 900 Upload/Download Management Software – An alternative way to program your system from a PC. Before you can utilize DLX 900, you will have to enable this functionality in the CPU by programming the Download Access Code. This can be accomplish via the UM-1820E touch screen keypad or the on board web server. Please see Section 3.3 for additional details. On-site Keypad – The UM-1820E touchscreen offers a programming menu allowing full system configuration. Refer to the installation manual. ...C... 34 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3.1 Programming via Web Server This system has a built in web server which makes it easy and simple to set up your system from a web browser instead of the keypad. Access to the Web Server is available locally when the computer or smart device is connected to the same LAN that the CPU is connected to. The Web Server is also available from remote locations when logged into the UltraSync portal. 3.1.1 Connect to LAN The CPU is shipped to automatically receive its IP address from the local router. Simply connect the CPU to the local router via the Ethernet cable then turn on the power to your system. It will take approximately 10 seconds for the local router to assign the system an IP address. 3.1.2 Retrieve the CPU IP address Retrieve the system’s IP address via the keypad. From the UM-1820E press: Menu – Program – ▼– Communicator – IP Configuration – IP Address Write down the IP address of the CPU. In the unlikely event that the router is not configured to automatically assign an IP Address, you will have to manually program an IP address for the system. Instructions to manually assign the network settings follows in section 3.1.3 below. 3.1.3 Manually Assign an IP Address If you are unable to get an IP address from the router automatically, then your router may not be configured to automatically assign an IP address (via DHCP) or certain security settings may be enabled. Contact the router’s network administrator for assistance and the assignment of the network settings for the CPU. 1. Turn DHCP off on the CPU. On the keypad press: Menu – Program – – Communicator – IP Configuration – – – IP Options – Enable DHCP. The display should show “N” to indicate that DHCP is disabled. 2. Manually assign network settings a. Press Menu – Program – – Communicator – IP Configuration b. Assign the following values that were provided by the network administrator: 1. IP Host Name (optional) 2. IP Address 3. Gateway 4. Subnet 5. Primary DNS 6. Secondary DNS (optional) 3. Connect your computer or smart device to the same router that the system is connected to. This connection to the router can be via Ethernet or Wi-Fi. Open your web browser on the device. If DHCP has been disabled in the router, you will have to manually ...C... 35 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. assign an IP address/network settings to your computer or smart device. Consult with the network administrator if required. 3.1.4 Login to the Web Server 4. Enter the IP address of the CPU into a web browser. The login screen shown below should appear. Some browsers may require you to enter http:// plus the system’s IP address. Enter your username and password. By default this is: installer and 9–7–1–3. You should now see a screen similar to one of the below: Your system is now successfully connected to your Ethernet network. Press Settings or Advanced to program your system. 3.1.5 Troubleshooting LAN Connections • Check your router settings and try again. • On the Touch Screen keypad press Menu – [PIN] – [ENTER] – Program – Communicator – IP Configuration – IP Options, this will allow you to modify connection settings including DHCP. • If the panel is connected to a local router which provides internet access, open up a web browser on your computer or smart device and verify that you have internet access (make sure cellular service is disabled on cellular enabled devices such as tablets and smart phones when connecting over the LAN). 3.2 Programming via UltraSync UltraSync is an app that allows cloud-based remote management and remote access to the system from an Apple® iPhone/iPad, or Google Android device. Download the UltraSync app. Carrier charges may apply and an Apple iTunes or Google account is required. 3.2.1 Set Up a Web Access Passcode for UltraSync For security, remote access via the UltraSync app is disabled by default. Follow these steps to enable it: Select Settings - Network from the Web Server. Enable remote access for the UltraSync app by changing the Web Access Passcode (WAP). This is an eight digit code that ...C... 36 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. permits access from the UltraSync application. The default Web Access Passcode of 00000000 prevents remote access. Enter a Web Access Passcode. Press Save. Follow this sequence to program the Web Access Passcode using the keypad: Menu – PIN – Enter – Program – Network Servers – Web Access Passcode For a detailed explanation of the function of the Web Access Passcode please see Section 5.6, Programming the Network. 3.2.2 Connect via UltraSync Application On Apple® devices go to the App Store™. On Android devices go to the Google Play™ store. Search for UltraSync. Install the app. Press the icon on your device to launch it. Press + on the top right to add a new site, or the blue arrow to edit an existing site. Enter the details of the security system. ...C... 37 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. The serial number is printed on the back of the panel. Alternatively login to the Web Server and go to Settings – Details to view it. You can also retrieve the serial number from the keypad. On the Touch Screen keypad press Menu – [PIN] – [ENTER] – Program – System – Status – Device Serial. The default username and PIN code for the installer is: installer and 9–7–1–3. The default username and PIN code for User 1, the Master User is User 1 and 1–2–3–4. You may also use any other valid user account. Users will only see and have access to menus at their permission level. Press the Done button to save the details, then Sites to go back. Press the name of the Site; the app will now connect you to your system. ...C... 38 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3.2.3 Check LAN Connection to UltraSync Servers 1. 2. 3. 4. Login to the UltraSync Web Server as shown above Click Settings Select Connection Status in the drop down menu Check: • LAN Status should display Connected. • UltraSync Status should display Connected. • UltraSync Media should display LAN. If it does not: Check cable connection and router settings. ...C... 39 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3.2.4 Troubleshooting UltraSync Setup 1. UltraSync Site Creation fails Cause Solution Check the serial number, web access passcode, user name and PIN codes match those in the system. Settings are entered incorrectly Web Access Passcode must not be 00000000. User Name must be entered with a space between the first and last name and with correct capitalization. 2. Cannot see local Wi Fi access point from smartphone Cause Solution Some hotspot access points may not accept 802.11g connections. Ensure your Wi Fi access point is able to accept 802.11b or 802.11g. 3. Network connections fail Cause Solution Ethernet not working If connected by Ethernet, check that the cable is plugged in and the connection is working. Network not set Check Settings – Network – Enable UltraSync is checked. 4. Cannot get IP address Cause Solution The wireless/router may not be configured for automatic DHCP or certain security settings may be enabled. Check with the router’s network administrator and configure the system as required. 5. Cannot access internet Cause Mobile device has no access Solution Open a web browser on your mobile device to double check access. Try disabling Wi Fi on your device once the system is configured and using the 3G/4G data connection of your device with the UltraSync app. 6. Server connections fail Cause Solution Check the UltraSync servers are correct. See Advanced Programming, Network Servers for reference. Server addresses are incorrect a. Ethernet Server 1 - zw1.UltraSync.com:443 b. Ethernet Server 2 - zw1.UltraSync Modular Hub.com:443 c. Wireless Server 1 - zw1w.UltraSync.com:8081 d. Wireless Server 2 - zw1w.UltraSync Modular Hub.com:8081 7. Configuration setting changes fail Cause Devices are not responding to inputs ...C... 40 P/N 466-5261 • REVA • ISS 11NOV16 Solution Re-initialize equipment. Power cycle connected equipment including customer supplied router(s). UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3.3 Programming via DLX 900 Management Software Another method to manage your system is to use the DLX 900 up/download software. DLX 900 supports a variety of connection methods: 1. Connection over LAN (local) 2. Remote connection 3. Remote connection over dial-up PSTN 3.3.1 Enable Remote Access for DLX 900 For security, remote access is disabled by default. Follow these steps to enable remote access for DLX 900: Select Settings - Network from the Web Server. Enable remote access to the Hub by changing the Web Access Passcode (WAP). This is an eight digit code that permits remote access to the Hub. The default Web Access Passcode of 00000000 prevents remote access. The Download Access Code enables remote access for DLX 900. Select Settings Network from the Web Server. Enable remote DLX 900 access by changing Download Access Code. This is an eight digit code. The default Download Access Code of 00000000 prevents remote DLX 900 access. 3.3.2 Connect using DLX 900 on LAN 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Turn on power to your system Connect an Ethernet cable from your laptop to the local router (or via Wi-Fi c connection) and wait 10 seconds for the local router to assign an IP address. On the keypad press Menu – [PIN] – [ENTER] – Installer – Communicator – IP Configuration – IP Address and note the IP address displayed. Install DLX 900 on a suitable computer. Start DLX 900 Create a new customer Enter the IP address of your system in DLX 900 Click Save Click Connect via TCP/IP Click Read All 3.3.3 Remotely Connect using DLX 900 on UltraSync In order for DLX 900 to connect to a panel remotely, you will need to know the Download Access Passcode and the unit must be enabled to allow remote connections. Please see section 3.5.1. 1. 2. 3. 4. Install DLX 900 on a suitable computer; refer to DLX 900 installation instructions. Start DLX 900 Create a new customer Enter the serial number, Download Access Passcode and Web Access Passcode of the system 5. Click Save 6. Click Connect via TCP/IP 7. Click Read All ...C... 41 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3.4 Programming via On-Site Keypad To Program the Web Access Passcode on the keypad press Menu – [PIN] – [Enter] – Program – Network Servers – Web Access Passcode. Reserved: Future Content 3.5 Recommended Items to Change INSTALLER PIN Always change this to prevent unauthorized access to the security system. Select Change PIN from the main menu to change the installer PIN. Add your support contact information to the UM-1820E touchscreen keypad. When a user taps the SOS key then Installer, the Service Provider name and Contact number you enter will be displayed on the keypad. Program this information into each keypad by tapping "menu" then "settings" then "labels" then "Installer” to access this portion of the keypad programming. WEB ACCESS PASSCODE AND DOWNLOAD ACCESS CODE These provide remote access to the UltraSync Web Server via the UltraSync app and DLX 900 management software. ...C... 42 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. ...C... 43 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 4 4 The UltraSync App 4.1 Install UltraSync App UltraSync is an app that allows you to control your hub from an Apple® iPhone/iPad, or Google Android device. First set up the hub’s Web Server then download this app. Carrier charges may apply and an Apple iTunes or Google account is required. On Apple® devices go to the App Store™. On Android devices go to the Google Play™ store. Search for UltraSync. Install the app. Press the icon on your device to launch it. Press + on the top right to add a new site, or the blue arrow to edit an existing site. Enter the details of your security system and choose the language you want to use. The serial number is printed on the back of the panel. Alternatively login to UltraSync Web Server and go to Settings – Details to view it. The default Web Access Passcode of 00000000 disables remote access. To change it, login to the hub’s Web Server and go to Settings - Network. The default username and PIN code is: installer and 9-7-1-3, and User 1 and 1-2-3-4. You may also use any other valid user account. Users will only see and have access to menus at their permission level. Press the Done button to save the details, then Sites to go back. ...C... 44 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Press the name of the Site; the app will now connect you to your hub. 4.1 Using the App The first screen that will appear once you connect is Arm/Disarm. This will display the status of your system and allows you to arm or disarm areas by pressing Away, Stay, or Off. From this screen you can also enable or disable Chime mode. The menu bar is located along the bottom of the screen. Press Sensors to view sensor status. From the Sensors screen you can press Bypass to ignore a sensor or press it again to restore it to normal operation. You may also add or remove a sensor from the Chime feature. ...C... 45 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Press to view any cameras connected to the system. This is a live view of the camera. Press to view the last recorded clip by that camera. clip progress You can also access video clips linked to History events. Press ...C... 46 from the History screen. P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Master users will have access to the full Users menu for creating and managing users. See Section 7, Users and Permissions for definitions of user levels and permissions. When you login with the Installer account you will also have access to additional menus for setting up and programming the system. Installer menu, Settings ...C... 47 P/N 466-5261 • REVA • ISS 11NOV16 Installer menu, Advanced UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 4.2 UltraSync Color Codes UltraSync’s display tiles are color coded for easy recognition. ...C... 48 Not Ready Ready Ready with at least 1 sensor bypassed Armed, Away Armed, Stay Message, Error P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. ...C... 49 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 5 5 System Settings These instructions describe how to program the system. The description and screenshots depicted below show the procedure utilizing the Web Server. Utilizing the UltraSync app is virtually identical. 5.1 Learn in Sensors Connect to the system (either via Web Server Configuration, or the UltraSync app). Enter your username and password. By default this is installer and 9–7–1–3. Press Sign In. You should see a screen similar to one of the below: Click on the Settings bar, and then select Sensors from the menu to see the list of programmable items. ...C... 50 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. At this point you can type the name of the sensor and define its profile, by determining the sensor type (Entry, 24 hour, fire, key switch, etc.) and the sensor options (bypass, force arm, Cross Zone, stay mode, etc.). You can also assign it a specific area. Each of these has a drop down menu to make selections. ...C... 51 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Sensor Type Sensor Options Sensor Area Group When all of your programming definition for the sensor is complete, press Learn if this is a wireless sensor. A notification box will appear below the learn button. Activate the sensor. Consult the sensor manual for instructions; generally this is performed by opening the case and manipulating the tamper activator. This will send a tamper signal. The notification box will alert you that a new device was found. ...C... 52 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. The screen below shows a sensor learned in. Name: Type: Option: Area Group: Serial Number: Front Door Entry Exit Delay 1 Bypass Area 1 A8E551 Note: The sensor’s Serial Number field is populated after learning in the sensor. Explanations of the sensor configurations appear on the next page. Also reference Advanced Programming, Sensors, Section 6. ...C... 53 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Sensor Configuration Menu Select Sensor to Configure Default Function 1 Sensor Choose among 64 sensors. Sensor Name Blank Custom 32 character name Sensor Type 3 Entry Exit Delay 1 Sensor types determine the sensor attributes such as entry/exit, instant, etc. Additionally sensor types determine the siren attributes. Sensor Option 1 Bypass Sensor options determine the sensor attributes such as a sensor’s ability to be bypassed, force arm, Cross Zone, stay mode, etc. Additionally sensor options determine the sensors reporting attributes. Area Group 1 Area 1 Assigning a sensor to an area will enable it to report. Blank This is the TXID of the wireless sensor, it can be manual entered or the sensor can be "Learned" into panel. Tamper On Tamper switch on the wireless sensor is enabled or disabled. Disable Internal Reed Off The internal reed switch(es) on the wireless device can be disabled. Applies if the sensor is a device type 10. Off The external input on wireless sensors can be enabled. Check this box when external contact is normally open. If the 60-362N-10-319.5 sensor is used the jumper pin does not have to be used. Applies if the sensor is a device type 10. Off At default the hub monitors its connections to wireless sensors, which broadcast supervisory packets to the panel. Disabling supervision makes the hub unresponsive to supervisory packets sent from that sensor. Typically used for mobile sensors such as wrist panic devices. Serial Number Norm Open External Contact Disable Supervision (Wireless Sensors) Voice Name 1 Blank Voice Name 2 Blank Voice Name 3 Blank Voice Name 4 Blank This feature uses the internal voice vocabulary to name the sensor. These names will be announced in sequence when the sensor is opened while in the Chime mode. These dialogue boxes appear after any changes to the system are attempted/registered. When you are finished programming the Sensor, Press the Save button. A dialogue box appears. Press the OK button. A dialogue box appears. Press the OK button. Note: After you have finished programming a sensor, be sure to advance the sensor number in the drop down menu when programming the next sensor. Otherwise you will over-write the sensor configuration you just programmed. ...C... 54 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.2 Learn in a Keyfob Click on the Settings bar, and then select Keyfobs from the menu to see the list of programmable items. With the keyfobs screen selected you can choose the keyfob number to configure and select the user number to link to the keyfob. Give the keyfob a number (you are giving the keyfob a sensor number). Select the user and press Learn. A notification box will appear below the learn button. Activate the keyfob. Consult the keyfob manual for instructions; this is performed by simultaneously pressing the lock and unlock buttons. This will send a tamper signal. ...C... 55 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. The notification box will alert you that a new device (keyfob) was found. The keyfob Serial Number box will be populated. Explanations of the Keyfob configurations appear on the next page. ...C... 56 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Keyfob Configuration Menu Select Keyfob to Configure User Default 193 Keyfob Use FOB Number as Standard User Function This is the starting Sensor number for Keyfobs. If "Use FOB Number as Standard User” is used, when there is an activation on that Fob the Central Station report will come in with that sensor number. If there is a user assigned to the fob that user number will come in on the Central Station Report. If no user is assigned it will show as user 999 in the Central Station Report. Police Off Enabling this will enable the Police / Panic on the Fob, this will also be audible at the panel (top 2 buttons press at the same time). No Siren on Police Off With this enabled it will make the Police / Panic silent at the panel. Auxiliary Off Enabling this will enable the Medical / Aux on the Fob. This will be an audible alarm at the panel. (bottom 2 buttons pressed at the same time) Scene Off By using the drop down menu one of 16 scenes can be activated. Serial Number Blank This is the TXID of the Fob, it can be manually entered or the sensor can be "Learned" into panel. When you are finished programming the Keyfob, Press the Save button. A dialogue box appears. Press the OK button. A dialogue box appears. Press the OK button. These dialogue boxes appear after any changes to the system are attempted/registered. ...C... 57 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.3 Programming Areas Click on the Settings bar, and then select Areas from the drop down menu to see the list of programmable items. With the Areas screen selected you can choose an Area number to configure, give the area a name, and define attributes for that area. The system can support a total of 4 areas; each area is configured with its entry and exit times, area options, area timers, area type and reporting characteristics. Explanations of the Area configurations appear on the following pages. Also reference Advanced Programming, Areas, Section 6.3. Note: When programming Areas 2 and above, a value of 0 for any Area Timer forces the system to utilize the Area 1 settings for the timer value. Also, a selection of “disabled” for the Area Channels option forces the system to utilize the Area 1 setting for the Area Channels. ...C... 58 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Select Area to Configure Area Timers Function Area 1 Use the drop down menu to select which of the 4 areas to program. Blank Each area can be configured with a custom 32 character name. The area name is displayed wherever an area is referenced on the system. Entry Time 1 (30-240) Seconds 30 Provides time to enter into the premises to deactivate the alarm system. Exit Time 1 (45 - 255) Seconds 60 Provides time to exit the premise without activating the alarm system. Entry Time 2 (30 - 240) Seconds 30 If there is a second entry door that requires more time to deactivate the alarm system. Exit Timer 2 (45 -255) Seconds 60 If there is a second exit door that requires more time to leave. Stay Enter Timer (30 - 240) Seconds 30 When the system is armed to "STAY" this will be the entry time to deactivate the alarm system. Off If enabled, the area can be armed in away mode with a single press. When area is armed via quick away mode, the closing user number is the default user of 999. Quick Disarm - Stay Mode Off If enabled, this will allow the stay mode to be disarmed by pressing the stay key on the keypad. If the system is in alarm a PIN must be used. Manual Panic On Enables or Disables the Keypad Panic Manual Fire On Enables or Disables the Keypad Fire Manual Auxiliary On Enables or Disables the Keypad Auxiliary Quick Arm Away (No PIN) Area Options Areas Configuration Menu Area Name Default If enabled, the area can be armed even if sensors are not ready. Any sensors that are not ready will NOT be automatically be bypassed and may cause an alarm condition because they could still be in a not ready state once the area becomes armed. Force Arm With Bypass Off This option is overridden if the Force Arm With Auto-Bypass is enabled. Individual sensors can be made “force arm-able without auto-bypass” by leaving this area option off, then enabling Forced Arm Enable in Sensor options, and disabling Sensor Inhibit (Bypass) in the Sensor Type Profile. ...C... 59 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Area Reporting Areas Configuration Menu Area Account Area Channels 0 1 Channel Group This account number is ONLY used when sending an email. This should be the same as the Central Station account number, however if it is not this will not affect the Central Station reporting This determines which channel will be used to report area events to the Central Station. The channel must be configured in the Channel option programming. When you are finished programming the Area settings, remember to save your changes. ...C... 60 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.4 Programming the System Click on the Settings bar, and then select System from the drop down menu to see the list of programmable items. When the System screen is selected you can program several system wide settings, including the system clock and timers, as well as sensor options and reporting. When you are finished programming the System settings, remember to save your changes. Explanations of the System configurations appear on the following pages. Also reference Advanced Programming, System, Section 6.1. ...C... 61 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Date &Time Function Date Once it is connected to UltraSync the Date and time are automatically synced. Time (hh:mm:ss) Once it is connected to UltraSync the Date and time are automatically synced. Hours Offset Daylight Saving Time Minutes Offset UTC 5 ET 0 EST is UTC-5, CST is UTC-6, MT is UTC-6, PST is UTC-7. This is used in other locations throughout the world. Start Month Mar Standard Start Week Second Standard End Month Nov Standard Start Month First Standard Siren Time (0-99) Minutes System Timers System Configuration Menu Default Time Zone Option 4 The siren time sets the time in minutes that the siren output is active. Battery Test Time (099) Minutes 2 The battery test time sets the duration in minutes that the system will perform a dynamic battery test. The system will perform a dynamic battery test at the disarming of the first area or at midnight once each 24-hour cycle. Dynamic battery test is disabled when the test duration is set to 0. Dynamic battery test can also be run manually from a keypad. Battery Missing Time (0-65) Seconds 0 The battery missing time sets the interval in seconds that the system will perform a missing battery test. This option is disabled when the test interval is set to 0. AC Failure Report Delay (0-999) Seconds Cross Zone Time (30-999) Seconds Sensor Inactivity Time (0-65535) Minutes 300 The AC fail report delay sets the duration in seconds that the AC power is lost or restored before a communication is initiated. AC restore will report when power is maintained for this same duration. 300 0 The Cross Zone time sets the duration in seconds whereby two or more sensors must trip before an alarm condition will be registered or the one sensor must trigger twice within this time period, or a continuous trip longer than 10 seconds. This feature only applies to sensors with the Cross Zone feature set in sensor options. Sensors programmed with Sensor Inactivity in the Sensor Options must be opened and closed within the time programmed here (in minutes). If they do not, a Sensor Inactivity will report. This feature can be enabled in the System Options menu. Default Sensor Inactivity option is off and this timer is set to 10080 minutes (7 days). ...C... 62 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System Timers Default Function 14400 This applies only to wireless sensors programmed as fire type. Sensors send a reduced packet count supervisory signal every 60 minutes (check your sensor manual for most up to date details). If no supervisory signal is received by the panel within the time specified here then the sensor will be reported as missing. When set to 0 the default of 14,400 seconds (4 hours) will be used. Check your local regulations for the correct value to use. 14400 This applies only to wireless sensors programmed as non-fire type. Sensors send a reduced packet count supervisory signal every 60 minutes (check your sensor manual for most up to date details). If no supervisory signal is received by the panel within the time specified here then the sensor will be reported as missing. When set to 0 the default of 43,200 seconds (12 hours) will be used. Check your local regulations for the correct value to use. Off If enabled, the eight (8) hardwired sensor inputs will be doubled to support sixteen (16) sensors. The terminals for Sensor 1 will represent sensors 1 and 9, and the terminals for sensor 2 will represent sensor 2 and 10 etc. This option cannot be selected for sensors other than the eight sensors on the main CPU. This option cannot be used in conjunction with the DEOL option. Off The system has a built-in normally closed tamper switch that will sound the siren if the tamper switch is opened or the wires are cut. This option will enable or disable this tamper switch. System Sensor Tamper Off If enabled, the system will monitor all sensors, except fire sensors, for Dual End of Line (DEOL). A short or open circuit on a DEOL will activate sensor tamper alarms. This feature cannot be used if Panel Zone Doubling is enabled. Disable Hardwire Sensors Off If enabled, the system will disable all hardwired sensor inputs on the CPU. Fire Supervise Time (120-65535) Seconds Burg Supervise Time (120-65535) Seconds Panel Zone Doubling System Options System Configuration Menu Option Panel Box Tamper Sensor Inactivity Off If enabled, the system will monitor each sensor for activations. If no activations occur within the sensor activity time then a failed sensor activity report may be reported via the selected communication channel and a failed sensor activity message set in the system event log. For a sensor to be eligible for activity monitoring, it must have Sensor Inactivity Test set in Advanced Programming, Sensor Options. System Reporting The Sensor Inactivity Time is set in Advanced Programming, System – System Timers. ...C... 63 System Channel P/N 466-5261 • REVA • ISS 11NOV16 1 Channel Group The Channel Group that the system will send system events to. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.5 Programming Reporting and Notifications Click on the Settings bar, and then select Reporting and Notifications from the drop down menu to see the list of programmable items. With the Channels screen selected you can program a communication path for events to be sent from the system to a selected destination. The system can support a total of 16 channels; each channel is identified by a unique channel number, which cannot be altered, and remains as the key reference for each channel. Choose a channel in the drop down menu and assign it attributes. Explanations of the Channel Configuration menu appear on the following page. Also reference Advanced Programming, Reporting and Notifications, Section 6.4. When you are finished programming the Channel settings, remember to save your changes. ...C... 64 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Reporting and Notifications Configuration Menu Option Default Select Channel to Configure ...C... 65 1 Central Station Primary Channel Name Account Number Format Dest Phone, Email or Push Notification Next Channel Event List Attempts P/N 466-5261 • REVA • ISS 11NOV16 Function Central Station Primary Custom names of the selected channel can be created here. Blank This is the Account Number that will be reported with the event in email reports. When UltraSync format is selected, this field will not be used. UltraSync This is the communication format for the selected channel. Select from: Use as Backup CID SIA 300 SIA 110 UltraSync Email-Push Notification Blank The phone number or email address of the selected destination. Central Station Backup 1 Central Station Backup 2 Email 1 Email 2 Email 3 Etc. If the channel selected is unable to deliver the event to the selected destination, the system will use this backup channel if the primary channel fails. The Next Channel specified here must be greater than the Channel Number. 1 Event List Select the pre-programmed list of events that will be sent via this channel. The specific event in each event list is programmed in Advanced Programming, Event Lists. 2 Enter the number of times the system should try to send the events to the UltraSync server. After the number of attempts has been exhausted the system will try the Next Channel if specified. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.6 Programming the Network Click on the Settings bar, and then select Network from the drop down menu to see the list of programmable items. Enter your network settings on this page. Explanations of the Network Configuration Menu appear on the following pages. Remember to save your changes when you are finished programming the Network settings. ...C... 66 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Default Function LAN Configuration The default IP Host Name is xgen. To access the web server without an IP address, simply type http://xgen into the web browser. Some browsers to not require http://. Network Configuration Menu IP Host Name - To change the IP Host Name, enter a new IP Host Name and hit the Save button. The saved change does not take effect until you log out of the Web server. PC’s typically cache this address for about 10 minutes. If you used the default xgen host name and then change it, the new host name will not be useable for this time frame. Note: This feature is not supported with Internet Explorer. This only works on the local LAN and with a Windows® PC, or an Apple MAC. The PC or MAC must have Netbios Name Service (NBNS) enabled. It does not work remotely over the internet. Remote access to the server is supported via the UltraSync Portal. Enable DHCP off Allows the system to be automatically assigned an IP address by the network. IP Address - The IP address assigned to the system which enables it to connect to the local LAN. This will allow you to access the embedded web server from the system to program and view the status of the system. It is also used for alarm reporting. Gateway - If required, the IP address of the router which is needed when remote IP communications are used. Subnet - The subnet mask for the network. For example, 255.255.255.0 is the network mask for 192.168.1.0/24 Primary DNS - The IP address of the Primary Domain Name Server. The DNS is used to translate host names for time servers and UltraSync servers. Secondary DNS - The IP address of the Secondary Domain Name Server, used if the Primary DNS is not available. 0 The UltraSync app requires the Web Access Code to get remote access to the panel. The default Web Access Passcode of 00000000 disables remote access. The system allows for an 8 digit numeric (only) code. Each owner should have a unique number. Download Access Code 0 Enables remote access for DLX 900. This is a variable length code for the computer user. This code gives the DLX 900 software complete authority over all menus including those that are locked. For convenience DLX 900 will also try installer and 9–7–1–3 to allow a connection if the Download Access Code does not work. This is why changing the default installer PIN code is important. The default Download Access Passcode of 00000000 prevents remote access. Automation User Name Blank Used when there is API integration Automation PIN Blank Used when there is API integration Remote Access PINS WEB Access Passcode Options Enable Ping ...C... 67 P/N 466-5261 • REVA • ISS 11NOV16 On Allows the system to respond to the PING command. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Default Function This is an automatic feature. It is recommended you leave this setting on. Enable this option to allow the system to send email reports via the UltraSync servers. This is independent of the Web Access Passcode which when set to 00000000 will prevent the UltraSync app from connecting. Network Configuration Menu Enable UltraSync On If any channel is set to Email format reporting, then the system will override ignore this setting and allow email reporting via UltraSync cloud servers. If you wish to prevent connections to the system’s cloud servers, then uncheck this option and do not use the UltraSync reporting format. Also reference the table in Advanced Programming, Communicator. Monitor LAN Off When the Monitor LAN option is enabled the panel will monitor the Ethernet port for a valid Ethernet cable. If the Ethernet cable is disconnected while this option is enabled and the panel is unable to communicate, it will log a Fail To Communicate event. Enabling this option will allow DLX 900 to connect at any time if the correct Download Access Code is provided. Always Allow DLX 900 On Disabling this option provides greater security by only allowing DLX 900 to connect when program mode is active. This allows the system to have DLX 900 access disabled until a user on site with physical access to the keypad enters program mode with a valid PIN code. The system will be in program mode if a user gains authorized access to the program menu via the keypad. Enabling this option will cause UltraSync Web Server and UltraSync app to always display Installer menus regardless of if the panel is in program mode or not. Enable Web Programming On Disabling this option will hide the Installer menus on UltraSync Web Server and UltraSync app unless program mode is active. This provides greater security by keeping web programming disabled unless a user on site with physical access to the keypad enters program mode with a valid PIN code. The system will be in program mode if a user gains authorized access to the program menu via the keypad. UltraSync app requires the Web Access Code to access to the panel. ...C... 68 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.7 Programming Automations (Scenes) Click on the Settings bar, and then select Automations (Scenes) from the drop down menu to see the list of programmable items. With the Scenes screen selected you can create scenes on schedules and determine which event types and device triggers will activate them. Each scene can trigger up to 16 consecutive scene actions when certain conditions are met. This can save users time by automatically running multiple actions. A scene can be triggered manually, through a schedule, or via a system event. Remember to save your changes when you are finished programming the Scene settings. Sequence Scene Configuration During IF Activate Schedule Then Perform Does Area, Sensor, Schedule, User, or Action Action 1 Up To Action 16 Activate Event Type Explanations of the Scene Configuration Menu appear on the following pages. Also reference Advanced Programming, Scenes, Section 6.18. ...C... 69 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Example Scene 1. Enter a scene name. 2. Select the When Should Scene Work drop down menu to restrict when the scene will be enabled. 3. Select the event that will trigger the automation using the Scene Trigger Type drop down menu. Choices here dynamically change the “Activate” selections. 4. Select Activate ( - - - - ) to assign what that triggers applies to. 5. Select the Scene Result. 6. Press Save. ...C... 70 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Default Function The system can support a total of 16 Scenes. Each Scene is identified by a unique number, which cannot be altered, and remains the key reference for each Scene. Select Scene to Configure Each Scene can be configured with a custom 32 character name. The name is displayed wherever a Scene is referenced on the system. Scene Trigger Scene Configuration Menu Scene Name When Should Scene Work Always On Select the Schedule that controls when this Scene is active. If the current date and time is outside of the selected schedule, then the Scene will not run. Scene Trigger Type Disable Select the event that will trigger this Scene. Choices here dynamically change the “Activate” selections. You can reference Activate Events list in Advanced Programming, Scenes. Activate (----) Disabled Select what triggers the Scene. Disabled Each scene can perform up to 16 Scene Actions. These are simplified actions that allow you to control devices on your system. Disabled There are two types of Results Scene Result 1 Device Scene Result 2 Device Scene Result 3 Device Scene Result 4 Device Scene Result 5 Device Scene Result 6 Device Etc. 1. Alarm System Results 2. Z-Wave Device Results. Disabled Disabled Alarm System Results Result Type - The event of the Action Result to perform. See Advanced Programming, Scenes and the Scene Action and Scene Action Events Types for reference. Disabled Disabled Etc. Result Number - Select the area / scene / camera number to control: Z-Wave Device Result To display Z-Wave Result Types you must first learn in a Z-Wave device. The Z-Wave device name will then appear. Device – select the Z-Wave device you want to control Etc. ...C... 71 P/N 466-5261 • REVA • ISS 11NOV16 Etc. Z-Wave Type 8 Setting 1 – depends on Z-Wave device. May include options such as On, Off, Heat, Cool, Auto, Up, Down, Lock, Unlock. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.8 Programming Schedules Click on the Settings bar, and then select Schedules from the drop down menu to see the list of programmable items. With the Schedules screen selected you can create up to 96 schedules, each having four time and day periods. Explanations of the Schedules Configuration menus appear on the following pages. Also reference Advanced Programming, Schedules, Section 6.6. Remember to save your changes when you are finished programming the Schedules settings. ...C... 72 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option ...C... 73 Schedule Name Function 1 Schedule 1 The system can support a total of 96 schedules. Each schedule is identified by a unique schedule number, which cannot be altered, and remains as the key reference for each schedule. Schedule 1 Each schedule can be configured with a custom 32 character name. The area name is displayed wherever a schedule is referenced on the system. Up to 16 Start and Stop times can be created. Note: The system handles schedules that span midnight automatically Time and Days 1 -16 Schedules Configuration Menu Select Schedule to Configure Default Start Time (hh:mm) - Enter in the start time End Time (hh:mm) - Enter in the stop time Monday - Tuesday - Wednesday - Thursday - Friday - Saturday - Sunday - Enter in the days of the week the schedule is to be active Enter in the holiday that this schedule will be following. Holiday 1 - Note: When the holiday is enabled the schedule will not be active. Holiday 2 - Same as Holiday 1 Holiday 3 - Same as Holiday 1 Holiday 4 - Same as Holiday 1 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.9 Programming Holidays Click on the Settings bar, and then select Holidays from the drop down menu to see the list of programmable items. With the Holidays screen selected you can create up to four sets of holiday dates for the system. Set the number, name and date range for each holiday. Holidays are then assigned to the schedules and used to deactivate the schedule while the holiday is active. Remember to save your changes when you are finished programming the Holidays settings. Explanations of the Holiday configurations appear below. Also reference Advanced Programming, Holidays, Section 6.13. ...C... 74 Select Holiday List to Configure 1 Holiday 2 Holiday 3 Holiday 4 Holiday Holiday # Holiday Name Start -End Holiday Configuration Menu Option Default Function n/a The system supports up to 4 sets of holiday dates, each set can have up to 16 date ranges. Holidays are used as part of Schedules to control access to the system on specified dates. n/a The system can support a total of 4 Holiday Sets. Each set is identified by a unique number, which cannot be altered, and remains as the key reference for each area. n/a Each holiday can be configured with a custom 32 character name. The name is displayed wherever a Holiday is referenced on the system. Start Date n/a End Date n/a P/N 466-5261 • REVA • ISS 11NOV16 Select the date range for the Holiday by specifying the start and stop date. A total of 16 ranges can be entered for each Holiday. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Example Office Worker User Permission 1 – All Areas Permission Schedule 1 – 8am8pm M-F, Holidays 1 (checked) An office is not staffed during a public holiday and you want to prevent access to the building from staff on this date. First program the holiday dates in this section under “Holiday 1”, then go to Schedules and check “Holidays 1”, then assign that schedule to the User. ...C... 75 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.10 Lock PIN Share Select Lock PIN Share from the drop down menu. This function allows you to send user PINs to Z-Wave door locks from the panel. Select the door lock you want to assign a PIN. Select an existing user (for their PIN) to send their PIN to the lock. You may also select all users at once. You may also remove user PINs from a lock, either all at once or by individual user. ...C... 76 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.11 Programming Cameras Click on the Settings bar, and then select Cameras from the drop down menu to see the list of programmable items. The system supports selected IP cameras. Contact your supplier for the correct model(s). Install camera according to the manual supplied with the camera. Once the camera has been connected to the same network as the system, proceed with the scanning of the camera from the system. Also reference Camera Setup Instructions, Section 9. Add a Camera Method 1 – Automatic Discovery Press Scan for New Cameras. The scan results in an IP address and MAC address listing in the form fields shown. Viewing Cameras in UltraSync 1. Log in to UltraSync app. 2. Press Cameras. 3. You will now be able to view the live camera feed. Add a Camera Method 2 – Manual Entry Reference Advanced Programming, Cameras, Section 6.20. Removing Cameras Reference Advanced Programming, Cameras, Section 6.20. ...C... 77 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Scan For New Cameras Default Function - Finds cameras added to the same IP network as the system. Camera Configuration This name can be up to 32 characters. Make sure the name Camera Name drop down (all cameras) matches the name you have set up in the camera app. Camera Network Configuration IP address assigned to the camera IP Address by the premises network MAC address assigned to the MAC address camera by the premises network Panel to Camera Connection - Notification Camera Menu Option Displays the last attempt by the panel to communicate with the camera on the LAN. The panel will try to communicate when: 1. A clip is triggered 2. Scan for New Cameras function is performed 3. Once per day Note: This does not indicate a camera to server or cloud connection; only the LAN. 5.12 Check Event History The UltraSync Modular Hub allows you to check the history of events that have occurred in the system. Press History and this menu will appear: Navigate to events recorded in the system with the arrow buttons. You can select the date for finding events and use the Event Filter dropdown menus to select among alarm events or video events. The system stores 1024 alarm events and 1024 video events. The display shows 10 events at a time. ...C... 78 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5.13 Check Connection Status Click on the Settings bar, and then select Connection Status from the drop down menu to see the system connection status. Also reference Advanced Programming, System, Section 6.1. Options Function Connection Status LAN Status Not Linked, Configuring, Connected (system connection status) Cellular State 1. Idle 2. Getting Details 3. Configuring Modem 4. Modem Connected 5. Configuring PPP 6. Authenticating 7. Configuring Protocol 8. Getting Echo 9. Connected 10. Terminating 11. Idle UltraSync Status 1. Idle 2. Selecting Server 3. Making Connection 4. Disconnecting 5. Retry Delay 6. Getting Server Hello 7. Connected UltraSync Path IP, Cellular Cellular Radio Details Cell Service No Service, Restricted Service, Valid Service Signal Strength -113 to -51 Notification - Diagnostic Connection Status Menu Connections Operator ID Radio Technology GSM, UMTS 5.14 Check Details Click on the Settings bar, and then select Details from the drop down menu to view the system details. Device Details Detail Status Control Name ...C... 79 Device Unique ID (UID) Ethernet MAC Address Control Model Firmware Version Hardware Version Bootloader Voice Version Website Version Memory Map Version Menu String Version P/N 466-5261 • REVA • ISS 11NOV16 Detail Set in System Settings Unique ID number of the system Ethernet MAC address assigned to the system by the premises network of the system " " " " " " " " " " " " " " " " " " UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 6 6 Advanced Programming Using Web Server Advanced settings are only accessible via the UltraSync Web Server, UltraSync app, or DLX 900. Click the Advanced bar to display the advanced menu. The Configuration Server page main tile contains different buttons than the settings tile. BACK: Moves you back to the main selection. UP: Moves you up one option through the programming options. DOWN: Moves you down one option through the programming options. ...C... 80 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. ALL ON / ALL OFF: Allows selecting or deselecting all the check boxes in menus like below. SHORTCUT: Allows quick navigation to the Advanced menu items or defaulting the system. Quick navigation to Advanced menu: A prompt will ask you to enter the Menu Shortcut. The format of the entry will be in a numerical format (X.Y.Z) following the System Menu Tree in Appendix 13. The first digit designates the top level menu. The second digit designates either the next menu level item or a specific the For example, to navigate to the System, General Options, enter a 2.2.1. To navigate to Sensor # 3, enter 3.3. Defaulting the system: A prompt will ask you to enter the Menu Shortcut.The shortcut can be used to either default the entire system or individual menus. The format is entered in a numerical format (910.xxx). A value of 910.910 defaults the entire sytem. To default an individual menu, enter 910.xx where xx designates the menu item to default. For example, a value of 910.2 will default the System menu items. A value of 910.22 will default the Cameras menu. See the table below for the numerical value of each menu item. 910.1 910.2 910.3 910.4 910.5 910.6 910.7 910.8 Users System Sensors Areas Reporting and Notification Communicator Schedules Actions 910.9 910.10 910.11 910.12 910.13 910.14 910.15 910.16 Auto Arm-Disarm Devices Permissions Area Groups Menus Holidays Sensor Types Sensor Options 910.17 910.18 910.19 910.20 910.21 910.22 910.23 Event Lists Channel Groups Action Groups Scenes Speech Tokens Cameras Network Servers Table of Menu Default Values ...C... 81 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.1 Advanced Programming, System Click the Advanced bar and select System from the menu to program system options. System Options is used to configure system wide options, such as time and dates, system timers and maintenance. ...C... 82 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System Submenus System Clock 1 System Clock 2 Clock Date and Time The system clock can manage day, time, time sensor, and day light saving time settings to ensure ongoing accurate time. 3 Time Zone Hours Offset / Minutes Offset 4 Daylight Saving Time Start Of DLST – Month 1 to 12 of year; Week of month 1 to 4 and last End Of DLST– Month 1 to 12 of year; Week of month 1 to 4 and last When connected to an IP network the system clock can synchronize its time and date automatically with an Internet Time Server if configured in Advanced Programming, Communicator. ...C... 83 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System General Options 1 General Options Option Default Function If enabled, the two (2) hardwired sensor inputs will be doubled to support four (4) sensors. The terminals for Sensor 1 will represent sensors 1 and 3, and the terminals for sensor 2 will represent sensor 2 and 4. This option cannot be selected for sensors other than the two sensors on the main panel. This option cannot be used in conjunction with the DEOL option. The system has a built-in normally closed tamper switch that will sound the siren if the tamper switch is opened or the wires are cut. This option will enable or disable this tamper switch. If enabled, the system will monitor all sensors, except fire sensors, for Dual End of Line (DEOL). A short or open circuit on a DEOL will activate sensor tamper alarms. This feature cannot be used if Panel Zone Doubling is enabled. Panel Zone Doubling Off Panel Box Tamper Off System Sensor Tamper Off Enable Celsius Scale Off Enable Celsius vs. Fahrenheit Scale. Disable Hardwire Sensors Off If enabled, the system will disable all hardwired sensor inputs on the CPU. Two Wire Smoke If enabled, the system will accept installed two wire smoke detectors. Strobe on Away & Off Off If enabled, the system strobe will flash when an area is set in away mode. The strobe outputs must be configured follow the area alarm event condition. The strobe is not activated on Disarm or Stay. On If enabled, system alarms such as tampers, low battery, A/C fail and trouble requires a user with “Reset System Alarms” enabled in their current Permission Options to reset the alarm condition. If disabled, system alarms do not latch and can be reset when a user arms or disarms an area. Off If enabled, the system will monitor each sensor for activations. If no activations occur within the sensor activity time then a failed sensor activity report may be reported via the selected communication channel and a failed sensor activity message set in the event log. For a sensor to be eligible for activity monitoring, it must have Sensor Inactivity Test set Advanced Programming, Sensor Options. System Alarm Latch Sensor Inactivity ...C... 84 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System Timers 1 System Timers Option Default Function Siren Time (0-99) Minutes 4 The siren time sets the time in minutes that the siren output is active. Walk Test Time (099) Minutes 15 The walk test time is the duration in minutes before a zone walk test will automatically end. ...C... 85 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Default Function Strobe Time (0-99) Hours 3 The strobe time is the duration in hours that output(s) programmed to follow the strobe time will activate. The valid time selection in this segment is 0 to 99 hours, where ‘0’ disables the Strobe Output. Output 2 on the CPU defaults to follow the Strobe Time when it is not assigned to an action. Battery Missing Time (0-65) Seconds 0 The battery missing time sets the interval in seconds that the system will perform a missing battery test. This option is disabled when the test interval is set to 0. 2 The dynamic battery test time sets the duration in minutes that the system will perform a dynamic battery test. The system will perform a dynamic battery test at the disarming of the first area or at midnight once each 24-hour cycle. Dynamic battery test is disabled when the test duration is set to 0. Dynamic battery test can also be run manually from a keypad. System Timers Battery Test Time (0-99) Minutes The AC fail report delay sets the duration in seconds that the AC power is lost or restored before a communication is initiated. AC Failure Report Delay (0-999) Seconds 300 Phone Fault Delay (0-6000) Seconds 0 The phone fault delay sets the duration in minutes before the phone line fault alarm condition is activated. Phone Restore Delay (0-99) Seconds 0 The phone restore delay sets the duration in seconds that the phone line fault condition must be restored before the phone fault alarm is reset. 300 The Cross Zone Time sets the duration in seconds whereby two or more sensors must trip before an alarm condition will be registered or the one sensor must trigger twice within this time period, or a continuous trip longer than 10 seconds. This feature only applies to sensors with the Cross Zone feature set in sensor options. 30 The report delay is the duration in seconds that non-24 hour and non-fire type sensors will delay before reporting. This provides a valid user the opportunity to reset an unintended alarm condition before that event is reported. 0 The holdup delay is the duration in second that a holdup delay sensor type will wait before it activates. If additional holdup activations occur during the holdup delay period then the holdup delay will immediately expire and set the holdup alarm. If a holdup delay sensor type is de-activated during the holdup delay period then the holdup alarm will reset and not activate. Cross Zone Time (30-999) Report Delay (1545) Seconds Holdup Delay (0-999) Seconds ...C... 86 P/N 466-5261 • REVA • ISS 11NOV16 AC restore will report when power is maintained for this same duration. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Option Default Function 120 The fire alarm verification feature is designed to reduce false alarms reported by smoke detectors. The system will wait 40 seconds to allow the smoke sensor to power up and settle. If a second trip occurs after this but before the end of the Fire Verify Delay time, a fire alarm will be generated. If no restoral is received after the first trip, a fire alarm will also be generated. The valid time selection in this segment is 120 to 255 seconds. The communicator will delay for a specified time before reporting the fire alarm Fire Verify Delay (0,120-255) Seconds Here are some scenarios: Fire Alarm Verification Time = 120 seconds System Timers 1st Trip ...C... 87 Restore No alarm 1st Trip No restoral 1st Trip Fire alarm reported Restore Reset 0s 2nd Trip Power Up 13 s 0 Fire Supervise Time (120-65535) Seconds 14400 Burg Supervise Time (120-65535) Seconds 14400 P/N 466-5261 • REVA • ISS 11NOV16 Waiting for second trip 40 s Sensor Inactivity Time (0-65535) Minutes Fire alarm Fire alarm reported Reset timer, wait for first trip 133 s Sensors programmed with Sensor Inactivity in the Sensor Options must be open and closed within the time programmed here (in minutes). If they do not, a Sensor Inactivity will report. This feature can be enabled in “System Options”. See Section 5.4. Default Sensor Inactivity option is off and this timer is set to 10080 minutes (7 days). This applies only to wireless sensors programmed as fire type. Sensors send a reduced packet count supervisory signal every 60 minutes (check your sensor manual for most up to date details). If no supervisory signal is received by the panel within the time specified here then the sensor will be reported as missing. When set to 0 the default of 14,400 seconds (4 hours) will be used. Check your local regulations for the correct value to use. This applies only to wireless sensors programmed as non-fire type. Sensors send a reduced packet count supervisory signal every 60 minutes (check your sensor manual for most up to date details). If no supervisory signal is received by the panel within the time specified here then the sensor will be reported as missing. When set to 0 the default of 43,200 seconds (12 hours) will be used. Check your local regulations for the correct value to use. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System Siren Options 1 Siren Options Siren Once Per Sensor If enabled, the system will only activate the siren once per sensor in a given arm cycle and will not activate the siren again even if that siren time expires and that sensor reactivates. Every sensor will have one siren activation attempt before that sensor cannot reactivate the siren. If this option is not enabled, at the expiry of the siren time any sensor can reactivate the siren an unlimited number of times. Siren Box Tamper If enabled, the system enables the siren box tamper feature on the CPU Tamp2 terminals. If the siren box tamper is tripped (e.g. opening the siren cover or wires cut), then an event will be generated. Siren At System Away or Disarm Siren At End Of Exit Siren At Arm Report Siren At Line Cut Armed Siren At Line Cut Disarmed Voltage Siren Output ...C... 88 P/N 466-5261 • REVA • ISS 11NOV16 If enabled, the system will activate the siren (Output 1) briefly each time the last area in the system is set in away mode or when the first area is disarmed by a keyfob. By default Output 1 is programmed to chirp. To enable this function by area, leave this option disabled in this section. Enable the “Siren at System Away/Disarm” in Area Options of Section 6.3 Advanced Programming, Areas for the area(s) you require. If enabled, the system will activate the siren (Output 1) briefly each time the system is set in away mode and the exit delay expires. By default Output 1is programmed to chirp. If enabled, the system will activate the siren (Output 1) briefly each time the system is set in away mode, with a keyswitch or wireless keyfob. The exit delay expires and a successful system arm report is acknowledged from the central station. The siren will chirp three times. By default Output 1 is programmed to chirp. If enabled, the system will set the siren for the siren time whenever the phone line is not detected and any area is armed. The phone line siren can be reset by the entry of a valid PIN. If enabled, the system will set the siren for the siren time whenever the phone line is not detected and all areas are disarmed. The phone line siren can be reset by the entry of a valid PIN. If enabled, the system will alter the oscillating siren output suitable for horn speaker to one that is a steady DC output that is suitable for DC sirens. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System Service and Test Options 1 Service and Test Options 2 Status Email Intervals If enabled, the system will report a system status email via one or more email channels. The number entered for Status Email Interval is the number of days between status reports. For example entering a 7 will cause a report to be sent every 7 days. The interval starts from either the first time you program an interval in here or when it is powered up. This is sent via System Event Reporting – Reporting Channels. 3 Status Email Time 4 Service Phone Number The status email time sets the time of day that the status email will report. This is set as 24-hour time in hours and minutes. ...C... 89 P/N 466-5261 • REVA • ISS 11NOV16 This feature is currently not used. Program the Company name and telephone number directly into the UM-1820E keypad by tapping Menu – Settings – Labels – Installer. When the user taps the SOS – Installer icons, this contact information will be displayed on the keypad. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1 Status 2 LAN Status Status of the connection to the Local Area Network. This menu provides diagnostic information on the connection status of the system. 4 UltraSync Status System Status 3 Cellular State Status of the connection to the cloud servers. Status of the connection to the cellular radio network. 5 UltraSync Path 6 Cellular service When connected to the cloud servers whether this is via LAN (Ethernet/WiFi) or cellular radio. When connected to the cellular radio network this will display what level of service is provided. If the optional radio module is installed with a valid SIM card, and this shows restricted service, please contact your service provider as your SIM card may not be provisioned correctly. ...C... 90 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 7 Signal Strength 8 Operator ID System Status If the optional radio module is installed with a valid SIM card, this will show the numeric signal level. If the optional radio module is connected to the network this will display the ID of the network operator. If the reported value is -121 to -86 then the signal level is too low. Install an external antenna to improve the signal level. If the reported value is -87 to -51 then the signal level is OK. 9 Radio Technology 10 Device Unique ID (UID) Unique ID number of the radio module. If the optional radio module is connected to the network this will display the connection technology such as GSM or UMTS. ...C... 91 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System Automation Menu System Counters 1 Counters ...C... 92 Swinger Shutdown is a false alarm prevention feature prevents a single sensor from activating more than a programmed number of times during a single arming period. After a certain number of alarms caused by the same sensor within the same arming period, the system will then shutdown that sensor for the remainder of that arming period. The sensor will be reactivated when the system is disarmed or rearmed to any security mode. See SIA CP-01-2010 Programmable Features Table for reference. 1 Automation Menu 2 Automation User Name This menu allows integration of 3rd party apps and devices. Used when there is API integration 3 Automation Pin Used when there is API integration P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.2 Advanced Programming, Sensors Click the Advanced bar and select Sensors from the menu to program sensor options. A sensor (sometimes referred to as a zone or input) on the system is a single physical hardwired connection or a non-physical wireless connection. Additionally sensors on the system can be used as logic inputs within actions and / or be configured as one of many sensor types. See Advanced Programming, Actions. Note: After you have finished programming a sensor, be sure to advance the sensor number in the drop down menu when programming the next sensor. Otherwise you will over-write the sensor configuration you just programmed. Sensor Submenus Sensor Submenus 1 Sensor Number 2 Sensor Name Each sensor can be configured with a custom 32 character name. The sensor name is displayed wherever a sensor is referenced on the system. 3 First Sensor Profile The system can support a total of 64 sensors. Each sensor is identified by a unique sensor number, which cannot be altered, and remains as the key reference for each sensor. ...C... 93 P/N 466-5261 • REVA • ISS 11NOV16 Sensor profiles determine the sensor type (Entry, 24 hour, fire, key switch, etc.) and the sensor options (bypass, force arm, twin trip, stay mode, etc.). Sensor profiles also determine the area in which the sensor resides in. Additionally, each profile has a schedule that the system uses to determine which of the two sensor profiles to use and when to use them. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Sensor Submenus 4 Sensor Type One of 32 configurable sensor types may be allocated to any sensor’s sensor type. Each sensor type can behave independently between an arm and disarmed state. Sensor types determine the sensor attributes, siren attributes, and sensor attribute options. Here is an example of a preset sensor type: ...C... 94 Sensor Type – 1 – Day Sensor Sensor Type Armed Sensor Type Disarmed Sensor Attribute - Instant Sensor Attribute - Local Siren Attribute - Yelping Siren Attribute - Silent Sensor Attribute Options: Sensor Attribute Options: Keypad Sounder YES Report Delay NO No Keypad Display NO Momentary Switch NO Sensor Inhibit (Bypass) NO Keypad Sounder YES Report Delay NO No Keypad Display NO Momentary Switch NO Sensor Inhibit (Bypass) NO P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5 Sensor Options 6 Area Group (1-16) Sensor Submenus One of 16 configurable area groups can be allocated to any sensor’s area group. Area groups are a list of system areas. When an area group is allocated to a sensor, that sensor will then belong to all the areas in the area group. If a sensor is assigned to multiple areas it will not arm until the last area is armed. It will also be disarmed when the first area is disarmed. Ensure the correct Area Group is assigned to a sensor. If an area Group with no areas is used, then the sensor will never report. 7 Schedule Number One of 32 configurable sensor options may be allocated to any sensor. Sensor options determine the sensor attributes such as a sensor’s ability to be bypassed, force arm, cross zone, stay mode, etc. Additionally sensor options determine the sensor’s reporting attributes. One of 16 configurable schedules can be allocated to any sensor’s schedule number. Sensor profile schedules determine when to allocate a sensor profile to a sensor. The first sensor profile has the highest priority and the second sensor profile has the lowest priority. The panel will check if the current time and day fall within the schedule of the first sensor profile or if the schedule is disabled (thus always active). If the schedule is active then that profile is applied to that sensor. If the first sensor profile’s schedule is not active then it will check the second sensor profile. If the schedule is active then that profile is applied to that sensor. ...C... 95 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 8 User Number The sensor user number feature is used whenever the sensor type is set to “keyswitch”. Instructions for users’ configurations are in Section 7 – Users and Permissions. One of 256 configurable users can be allocated to any sensor’s user number. The system’s sensor profile user number is a powerful feature that is used to apply the selected user’s attributes to a keyswitch operation. When the keyswitch sensor is activated, the system will check the user permissions and permission schedules to determine which areas are accessible. Additionally, area open and close reports will also report the user number selected in this option. Note: If the user number is programmed to 0, the system will use a default User number of 999 and will operate on all areas in the sensors area group. Sensor Submenus 9 Second Sensor Profile (Refer to First Sensor Profile) Example Diagram Sensor 12 – Living Room Motion Sensor First Sensor Profile Second Sensor Profile Sensor Type – Event Only Sensor Type – Always On Sensor Options – Bypass Forced Arm Sensor Options – Bypass Forced Arm Schedule 1 – Office Hours Mon-Fri, 8am-6pm, Holidays 1 Schedule 2 – Always On All Days, 24/7 Sensor Programming Event Only 8am ...C... 96 P/N 466-5261 • REVA • ISS 11NOV16 Always On 6pm UltraSync Modular Hub Reference Manual 8am ©2016 United Technologies Corporation .. I ... .. . .. 6.3 Advanced Programming, Areas Click the Advanced bar and select Areas from the menu to program area options. Areas Submenus Areas Submenus 1 Area Number 2 Area Name Depending on the model, the system can support up to 96 areas. Each area is identified by a unique area number, which cannot be altered, and remains as the key reference for each area. Each area can be configured with a custom 32 character name. The area name is displayed wherever an area is referenced on the system. ...C... 97 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Areas Submenus 3 Area Entry-Exit times The system uses the area entry and exit timers to delay the activation of an alarm event when entry/exit sensor types are activated. When an area is turned on, it will start an Exit 1 timer. While an Exit 1 timer is running – Entry 1, Entry 2, and Follower sensor types will not create an alarm. When the Exit 1 timer expires it will start the Exit 2 timer. While an Exit 2 timer is running – Entry 2 sensors will not create an alarm. Once all exit delays are expired, an activation on an Entry 2 sensor type will start an Entry delay with the Entry 2 time, and an activation of an Entry 1 sensor type will start an Entry delay with the Entry 1 time. If an entry delay is running and a sensor is activated with an entry time that is less than the time remaining, the timer will be reduced to the time of that new sensor. When configuring Area 2 and above, the Entry and Exit times default to 0. When the Entry and Exit times are set to 0, the system uses the Entry and Exit times configured for Area 1. A non-0 value will use that value for the Entry or Exit time. Activation of a Follower sensor while an entry timer is not running will create an instant alarm. If a sensor is in more than 1 area, the sensor will use the have the longest entry and exit delay time of the programmed area. If an area greater than 1 has the time set to 0, that area will use the time programmed in Area 1. Stay Entry Time The stay entry time is the entry warning time that applies to all sensors armed in the stay mode. This stay entry time only applies to Entry/Exit zones. ...C... 98 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Areas Submenus 4 Area Options 1. Arm/Disarm Reports If enabled, this area will send open and close reports via one or more appropriately configured channels. 2. Quick Arm Away (No PIN) If enabled, this area can be armed in away mode via a single away mode key press. When an area is armed via quick away mode, the closing user number is the default user of 999. 3. Arm In Stay If No Exit If enabled, Arm In Stay If No Exit will cause this area to arm in stay mode even when a user arms it in away mode, providing that an entry 1 or entry 2 sensor type is not triggered during the exit delay. 4. Quick Disarm - Stay Mode If enabled, this will allow the stay mode to be disarmed by pressing the stay key on the keypad. This is only possible if there is no alarm active and the stay entry delay is currently running. At the end of the stay entry delay or if there is an area alarm, the stay mode can only be disarmed via a valid user PIN. 5. Siren Chirp Away If enabled, the system will activate the siren (Output 1) briefly each time this area is set in away mode or disarmed with a key-switch or wireless keyfob. By default Output 1 is programmed to chirp. 6. Siren Chirp Stay If enabled, the system will activate the built-in siren briefly each time this area is set in stay mode with a key-switch sensor or wireless keyfob. ...C... 99 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 7. Force Arm With Bypass If enabled, the area can be armed even if sensors are not ready. Any sensors that are not ready will automatically be bypassed. The bypass will be logged in the event history. The automatic bypass will be applied when the sensor is capable of causing an alarm condition due to a state change such as an area arming, schedule or action. This avoids false alarms. If an auto-bypassed sensor becomes ready after it is armed, that sensor will automatically remove the bypass, log the bypass restore, and optionally report the bypass restore. Individual sensors can be made “force armable with auto-bypass” by leaving this area option off, then enabling Forced Arm Enable in Sensor options, and enabling Sensor Inhibit (Bypass) in the Sensor Type Profile. 8. Force Arm Without Bypass If enabled, the area can be armed even if sensors are not ready. Any sensors that are not ready will NOT be automatically be bypassed and may cause an alarm condition because they could still be in a not ready state once the area becomes armed. Areas Submenus This option is overridden if the Force Arm With Bypass is enabled. Individual sensors can be made “force armable without auto-bypass” by leaving this area option off, then enabling Forced Arm Enable in Sensor options, and disabling Sensor Inhibit (Bypass) in the Sensor Type Profile. 9. Manual Fire If enabled, the manual fire button will be enabled on keypads. Press and hold for 2 seconds to send a fire event. Default is off. 10. Manual Auxiliary If enabled, the manual auxiliary button will be enabled on keypads. Press and hold for 2 seconds to send an auxiliary event. Default is off. 11. Manual Panic If enabled, the manual panic button will be enabled on keypads. Press and hold for 2 seconds to send a panic event. Default is off. 12. Use Area 1 Options If enabled, the selected area will use the options chosen for Area 1. The panel ignores all other selections made; it overrides them to instead use the options chosen for Area 1. Default is on. 13. Bypass Requires PIN If enabled, a valid PIN code with access to this area is required to bypass sensors in this area. 14. Manual Panic is Silent If enabled (in Settings), manual panic alarms will not trigger an audible alarm. 15. Arm In instant If No Exit If enabled, this area will arm in Stay Instant mode when attempting to arm in Away mode and there is no exit. ...C... 100 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Notes on Force Arming, Bypass, and Auto-Bypass To arm an area it must first be “Ready to Arm”. This means all sensors in that area must be closed. For example, if the front door is open, then a user would need to close it first and ensure there is no movement in the reception area. This provides the Ready to Arm status in Area 1 that is needed before attempting to arm. This is not always user friendly or practical. The term force arm refers to the ability to arm an area even though sensors are not ready. It is usually only used with motion sensors as these are self-restoring and will be restored by the time the exit delay ends (e.g. the person arming the system leaves the building causing the Reception PIR to restore.) If the front door is not closed properly then Area 1 would go into alarm at the end of the Exit time. To avoid this false alarm we enable “Force Arm With Auto-Bypass” so all sensors that are not closed (i.e. not ready) by end of the exit time will be “Auto-Bypassed”. Areas Submenus If after the Area is armed, that sensor restores (e.g. the person double checks and secures the front door) then the Auto-Bypass will be removed from the sensor and it will be active. If subsequently the sensor is triggered then Area will go into alarm. Auto-bypass will be applied (if enabled, and if necessary) to a sensor whenever a change in state occurs that would result in an alarm condition. These include arming an area with a not-ready sensor, a sensor changing profile, Arm-Disarm function, or due to an action or schedule. Enabling Auto-Bypass for the area will apply the feature to all sensors in that area as well. In general disabling “Sensor Auto-Bypass” is not recommended because of the potential to create a false alarm but there are applications where it is desired. Use “Force Arm Without Auto-Bypass” at the area level to prevent sensors from being auto-bypassed when Force Armed. AREA 1 - Office [ ] Force Arm With Auto-Bypass [ ] Force Arm Without Auto-Bypass SENSOR 1 – Door Reed Switch SENSOR TYPE [ ] Sensor Auto-Bypass SENSOR OPTIONS [ ] Force Armed Enabled [ ] Bypass SENSOR 2 – Reception PIR SENSOR TYPE [ ] Sensor Auto-Bypass ...C... 101 P/N 466-5261 • REVA • ISS 11NOV16 SENSOR OPTIONS [ ] Force Armed Enabled [ ] Bypass UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. All Sensors Ready = Area Ready Sensors Not Ready = Area Not Ready to Arm If Auto-Bypass enabled then auto-bypass all not ready sensors Auto-bypassed sensor is restored Bypassed sensors remain bypassed Else Alarm Areas Submenus Arm Sensor restores Auto Arm Warning Exit Time Area Armed If “Arm In Stay If No Exit” disabled, and entry/exit zone tripped, Arm in Away mode If “Arm In Stay If No Exit” enabled, and entry/exit zone not tripped, Arm in Stay mode Entry/Exit Sensor Tripped Area Armed ...C... 102 Force Arm Alarm if valid code not entered Auto Arm Warning P/N 466-5261 • REVA • ISS 11NOV16 Exit Time Auto-bypassed sensors restored Bypassed sensors restored Area Disarmed UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5 Area Timers Auto Arm Warning Areas Submenus If the area type is Standard and Arm / Disarm is configured, this timer delays arming by the minutes entered. If the area type is Timed Disarm, Man Down, or Guard Tour, this setting is a warning time given to a user once the user’s Disarm Time, Man Down Time, or Guard Tour Time has expired. During this warning time a user can cancel the automatic re-arming and event report by entering their code, this will also restart the appropriate user timer. At the end of the warning time the system will re-arm the area and send the appropriate event (closing, man down, guard tour fail). If the area type is Early Open & Late Close, this timer sets the period after the start (opening) and after the end (closing) of the area type schedule that the area can be disarmed or armed. Otherwise an early to open or late to close report will be sent if enabled in user permissions. Fail to open and fail to close report will be sent if Arm-Disarm Reports is enabled in area options. Valid values are from 0 to 99 minutes Local Alarm Reminder If set, the local alarm reminder is the period in minutes between 0 and 999 that may elapse between actioning a local alarm and the local alarm reactivating if that sensor has remained open. For example if a smoke detector is removed to change the battery the tamper will trip; if a user resets the alarm on the system but does not replace the smoke detector within the local alarm reminder time, then the fire alarm tamper will retrigger. 6 Area Type Standard The area functions as normal. Timed Disarm Timed disarm is used when an authorised user can disarm an area for a predetermined period of time. At the end of this disarm time the area will start the auto-arm process ensuring that the area is not accidently left disarmed. ...C... 103 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. The following conditions must be true before a timed area disarm function will occur. a. b. c. i. ii. iii. The area type must be set to Timed Disarm. The area type schedule must be active. The user’s active profile’s permission must have: This area set in the permission’s timed disarm area group. The permission must be in schedule. The permission’s Area Type Override must NOT be set. At the end of the user’s disarm time, the Area Type Delay will activate for the set period. At the end of the Area Type Delay period the area will arm and start the Exit Delay and if configured, report a closing using via the last user number to have time disarmed the area. At anytime during the timed disarm period, authorised users with Area Type Override set in their active profile can cancel the disarm time period by arming or disarming the area. Areas Submenus The user’s permission determines how long the area will be disarmed for. Man Down Man down is used when an authorised user(s) is working in a hazardous area (or the like), and there is a requirement that the user(s) regularly “check-in” to notify others that the user(s) is safe. If the authorised user(s) fails to perform this action the system can set an audible warning and send a report. The following conditions must be true before man down function will occur. a. b. c. i. ii. iii. The area type must be selected to man down. The area type schedule must be active (after the start time and before the end time). The user’s active profile’s permission must have: This area set in the permission’s man down group. The permission must be in schedule. The permission’s Area Type Override must NOT be set. The man down timer is set in the user’s permission. At the end of the user’s man down time, the Area Type Delay will activate for the set period. At the end of the Area Type Delay period the area will arm and if configured, report a man down alarm. At anytime during the man down period, authorised users with the Area Type Override set in their active profile will cancel the man down time period by disarming or disarming the area. Guard Tour Guard tour is used when an authorised user(s) (such as a guard) is required to regularly “check-in” to notify others that they have physically attended to a location(s) on the site. If the authorised user(s) fails to perform this action the system can set an audible warning and report a “Guard Tour Fail” event. The following conditions must be true before guard tour function will occur. a. The area type must be selected to guard tour. b. The area type schedule must be active (after the start time and before the end time). c. The user’s active profile’s permission must have: i. This area set in the permission’s guard tour group. ii. The permission must be in schedule. iii. The permission’s Area Type Override must NOT be set. The guard tour time is set in the user’s permission. At the end of the user’s guard tour time, the Area Type Delay will activate for the set period and keypad sounder will be active. At the end of the Area Type Delay period the area will arm and if configured, report a Guard Tour Fail alarm. At anytime during the guard tour period, authorised users with the Area Type Override set in their active profile will cancel the guard tour time period by disarming or disarming the area. ...C... 104 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Early Open/Late Close If the area type is Early Open & Late Close, the Auto Arm Warning sets the period after the start (opening) and the end (closing) of the area type schedule that the area must be either disarmed or armed to avoid an exception report. If the area is not disarmed (opened) within the opening window a Fail to Open message is sent. When the area is subsequently disarmed, a Late Open message is sent. If the area is not armed (closed) within the closing window a Fail to Close message is sent. When the area subsequently armed, a Late Close message is sent. Areas Submenus For example, if the area type schedule is set between 8:00 AM (opening time) and 5:00 PM (closing time) and the Area Type Delay is set to 15 minutes; then the area must be disarmed between 8:00 AM and 8:15 AM otherwise if it is disarmed before 8:00 AM it is an early open, if it is disarmed after 8:15 AM it is late to open. Likewise the area must be armed between 5:00 PM and 5:15 PM otherwise if it is armed before 5:00 PM it is an early close, if it is armed after 5:15 PM it is late to close. 7 Area Type Schedule One of 96 configurable schedules can be allocated to the area type schedule. The area type schedule determines the schedule that the selected area type is active. Area types are not active when the schedule is not active. If an area type schedule is disabled (always active) that area will always have the type characteristics programmed in Area Type. ...C... 105 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Area Type Delay If the area type is Standard and Arm / Disarm is configured, this timer delays arming by the minutes entered. If the area type is Timed Disarm, Man Down, or Guard Tour, this setting is a warning time given to a user once the user’s Disarm Time, Man Down Time, or Guard Tour Time has expired. During this warning time a user can cancel the automatic re-arming and event report by entering their code, this will also restart the appropriate user timer. At the end of the warning time the system will re-arm the area and send the appropriate event (closing, man down, guard tour fail). Areas Submenus If the area type is Early Open & Late Close, this timer sets the period after the start (opening) and after the end (closing) of the area type schedule that the area can be disarmed or armed. Otherwise an early to open or late to close report will be sent if enabled in user permissions. Fail to open and fail to close report will be sent if Arm-Disarm Reports is enabled in area options. Example Area Type – Early Open & Late Close Area Type Schedule – 8:00 to 17:00 Area Type Delay – 15 min User Permissions – Options – Open/close report, Early open report, Late close report Area Options – Arm-Disarm Reports Send Early Opening Send Fail to Open Send Open Send Late Open Automatically sent Area Disarmed Area Disarmed Close Window Area is Armed Open Window Area is Armed Area Type Delay 8:00 Send Early Close Send Close Area Disarmed 8:15 Send Fail to Close Send Late Closing Automatically sent Area Armed Area Armed Open Window Area is Disarmed Close Window Area is Disarmed 17:00 ...C... 106 P/N 466-5261 • REVA • ISS 11NOV16 Area Armed Area Type Delay 17:15 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Areas Submenus 8 Area Event Reporting/Account 9 Area Event Reporting/Channels If set, the area account code is a system unique 4 to 10 digit code (format dependent) used to associate area related alarm reporting events to this area. If the area account code is equal to the default of 0, the channel account code will be used for this area’s alarm reporting events. If the channel account code is equal to the default of 0, the channel 1 account code is used. If the channel 1 account code is 0 then the account will be sent as 0. The channel group determines which communicator channel(s) area events will be reported to. If the tick box corresponding to one of the 16 reporting channels is checked, area events will always be reported to this channel. It is referred to as a primary reporting channel. If a report is unsuccessful to a particular primary channel it will attempt that channel’s backup channels if there are any. ...C... 107 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.4 Advanced Programming, Reporting and Notifications Click the Advanced bar and select Reporting and Notification from the menu to program reporting and notification options. The system can support a total of 16 channels; each channel is a communication path for events to be sent from the system to a selected destination. Default configuration reserves Channels 1 – 3 for UltraSync format, Channels 4 – 16 are Email format. Email is a “best-effort” system and there is no guarantee messages will be delivered by the network. When the network is busy, messages can be dropped. Central control room monitoring is highly recommended as each event is acknowledged on receipt to ensure an appropriate response can be made. Installers have access to setup/modify all channels (1-16). Master Users have access to channels 7-16, which are used for email notifications. Standard users do not have access to channels. Reporting & Notifications Submenus R&N Submenus 1 Channel Number 2 Channel Name Custom names of the selected channel can be created here. 3 Account Number The system can support a total of 16 channels. Each channel is identified by a unique channel number, which cannot be altered, and remains as the key reference for each channel. Channel 1 and channels 4-16 are configured as primary reporting paths by default. Channel 1 reports to UltraSync by default. Use as Backup as the Format selection has the effect of disabling reporting of a primary channel. The Format must be selected to a value other than Use as Backup to enable reporting. Channels 4-16 are configured as email reporting paths by default. ...C... 108 P/N 466-5261 • REVA • ISS 11NOV16 This is the Account Number that will be reported with the event in email reports. When UltraSync format is selected, this field will not be used. Channels 2 and 3 are configured as backup reporting paths by default. Channel 2 is set to disabled and channel 3 is set to back up channel 2 by default. Note that the primary channel must set the Next Channel for back up reporting to function. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 4 Format 5 Device Number Reporting & Notifications Submenus Reserved for future use Format is the communication format for the selected channel. Selections available in the drop down menu are shown. When Use as Backup is selected, the backup path will utilize the primary channel’s format. Note that the primary channel must set the Next Channel for back up reporting to function. Note: Selecting CID or SIA enables PSTN reporting. If utilizing PSTN reporting you need to enter a destination phone number. This is available in the Settings, Channels Menu. When UltraSync is selected as the Format, the reporting path will be over the Ethernet connection. When a cellular module is installed, it will automatically act as a failover path if the Ethernet path fails. There is no requirement to configure the cellular path as a backup reporting path. When Email is selected as the Format, the reporting will be directed to the configured email address. (Ethernet or Cellular connection required) 6 Destination Phone/Email/Push 7 Next Channel 1-16 The destination of the notifications. If the channel selected is unable to deliver the event to the selected destination, the system will try to use this backup channel instead. The Next Channel specified here must be greater than the Channel Number. A number lower than the current Channel Number will end the chain. This is to prevent accidental programming of endless loops. 8 Event List 1-16 9 Attempts Select the pre-programmed list of events that will be sent via this channel. The specific events in each event list are programmed. Enter the number of times the system should try to send the events to the UltraSync server. After the number of attempts has been exhausted the system will try the Next Channel if specified. ...C... 109 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. R & N 10 Language The reporting language used can be selected among four options. ...C... 110 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Configure Email Reporting 1. Login to the UltraSync Web Server or UltraSync app. Use an Installer or Master user account. 2. Press Settings. 3. Select Channels in the drop down menu. 4. Press Select Channel to Configure where the Format is already set to Email. 5. 6. 7. 8. Enter an email address. Select an Event List. Enter a Channel Name for future reference. Press Save. Installer and Master User types can customize Event Lists for selective reporting. ...C... 111 P/N 466-5261 • REVA • ISS 11NOV16 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.5 Advanced Programming, Communicator Click the Advanced bar and select Communicator from the menu to program communicator options. The system’s Communicator is a core component of the system used in conjunction with the Channels feature to report events to a monitoring company or third party. In this menu you can configure the settings for various methods of reporting. Communicator Submenus 1 General Options ...C... 112 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1. First Disarm Last Arm If enabled, the system will only send a closing report when the last area is armed. Note: The last area to arm must have open/close reports enabled. The system will only send an opening report when the first area is disarmed. This feature is used in place of Individual area Open and close. If you enable open and close in the area you will get both individual open and close and System open close Communicator Submenus 2. Report Once Per Sensor If enabled, this will limit reporting to only once per sensor each time you arm or disarm an area. This stops the control room or reporting destination to be flooded by multiple reports that the same sensor is being activated (for example the intruder may be moving around and is being picked up by the sensor on that zone). 3. Suppress Force Arm Bypass If enabled, the system does not send bypass reports when a sensor is forced armed. If not enabled, when a sensor is forced armed and it remains in a state of creating an alarm, bypass reports are sent at the end of exit time. For example this would occur if it remains open at the end of the exit time, or due to change of sensor type caused by a schedule. If forced armed sensors re-close during the armed period, bypass restores are sent. 4. Immediate Restore If enabled, the system will immediately send all restorals as the sensor reports the event. If not enabled, the system will send restoral events all at the same time when the marea is disarmed. 2 Auto Test/Intervals 3 Auto Test/Time Enter the time at which the automatic test report should be sent. This should be in 24-hour format. For example 18:00. Set day of the week to send an automatic test report to the system channel group . (Communicator\System Event Reporting\System Channels). You may also set auto-test to Daily. ...C... 113 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Communicator Submenus 4 IP Configuration 5-6 IP Config Detail 7-10 IP Config Detail IP Host Name The default IP Host Name is xgen. To access the web server without an IP address, simply type http://xgen into the web browser. Some browsers to not require http://. To change the IP Host Name, enter a new IP Host Name and hit the Save button. The saved change does not take effect until you log out of the Web server. PC’s typically cache this address for about 10 minutes. If you used the default xgen host name and then change it, the new host name will not be useable for this time frame. Note: This feature is not supported with Internet Explorer. This only works on the local LAN and with a Windows® PC, or an Apple MAC. The PC or MAC must have Netbios Name Service (NBNS) enabled. It does not work remotely over the internet. Remote access to the server is supported via the UltraSync Portal. Gateway If required, the IP address of the router which is needed when remote IP communications are used . Subnet The subnet mask for the network. For example, 255.255.255.0 is the network mask for 192.168.1.0/24. Primary DNS The IP address of the Primary Domain Name Server. The DNS is used to translate host names for time servers and UltraSync servers. Secondary DNS The IP address of the Secondary Domain Name Server, used if the Primary DNS is not available. IP Address The IP address assigned to the communicator to enable it to connect on to the local LAN. This will allow you access to the embedded web server from a web-enabled device to program and view the status of the system. It is also used for alarm reporting. ...C... 114 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11 Ports 12 Time Server Communicator Submenus The ports that the computer needs to communicate with the system. Enter the URL or IP address of a time server to allow the system to automatically update and synchronise its clock without user intervention. The default is pool.ntp.org Defaults: HTTP Port = 80 HTTPS Port = 443 13 IP Options 1. Enable DHCP Allow the system to be automatically assigned an IP address by the network. 2. Require SSL Feature no longer supported. Leave unchecked. 3. Enable Web Updates - RESERVED Allows the system to update the web pages via a network. Go to Hostname/mpfsupload to update the web pages served by the system. Does not update firmware. 4. Enable Ping Allows the system to respond to the PING command. 5. Enable Clock Updates Allows the system’s internal clock to synchronise with the internet time server specified . ...C... 115 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6. Enable Web Program Enabling this option will cause UltraSync Web Server and UltraSync app to always display Installer menus regardless of if the panel is in program mode or not. Disabling this option will hide the Installer menus on UltraSync Web Server and UltraSync app unless program mode is active. This provides greater security by keeping web programming disabled unless a user on site with physical access to the keypad enters program mode with a valid PIN code. The system will be in program mode if a user gains authorized access to the program menu via the keypad. UltraSync app requires the Web Access Code to access to the panel. 7. Always Allow DLX 900 Communicator Submenus Enabling this option will allow DLX 900 to connect at any time if the correct Download Access Code is provided. Disabling this option provides greater security by only allowing DLX 900 to connect when program mode is active. This allows the system to have DL900 access disabled until a user on site with physical access to the keypad enters program mode with a valid PIN code. The system will be in program mode if a user gains authorized access to the program menu via the keypad. 8. Monitor LAN When the Monitor LAN option is enabled the panel will monitor the Ethernet port for a valid Ethernet cable. If the Ethernet cable is disconnected while this option is enabled, and the panel is unable to communicate, it will log a Fail To Communicate event. 9. Enable UltraSync This is an automatic feature. It is recommended you leave this setting on. Enable this option to allow the system to send email reports via the UltraSync servers. This is independent of the Web Access Passcode which when set to 00000000 will prevent the UltraSync app from connecting. If any channel is set to Email format reporting, then the system will override this setting and allow email reporting via UltraSync cloud servers. If you wish to prevent connections to the system’s cloud servers, then uncheck this option and do not use the UltraSync reporting format. Reporting Enabled* No No No No Yes Yes Yes Yes Web Access Passcode 00000000 00000000 non 00000000 non 00000000 00000000 00000000 non 00000000 non 00000000 Enable UltraSync No Yes No Yes No Yes No Yes Connection to UltraSync Servers No Yes Yes Yes Yes Yes Yes Yes * Includes email and UltraSync reporting for all channels ...C... 116 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 17 Cellular Configuration 18 Username (optional) Optional username for APN. This is normally not used unless a non-standard cellular SIM is utilized. 19 Password (optional) 20 APN (optional) Communicator Submenus Optional password for APN. This is normally not used unless a non-standard cellular SIM is utilized Optional Access Point Name (APN) for the gateway between the cellular network and the public Internet. This is normally not used unless a non-standard cellular SIM is utilized. 21 Remote Access 22 Panel Device Number 23 Download Access Code A number from 0 to 4,294,967,295 that must be entered in to the desktop software for remote access to take place. This is a variable length code for the computer user. This code gives the DLX 900 software complete authority over all menus including those that are locked. For convenience DLX 900 will also try installer and 9–7–1–3 to allow a connection for first time set up if the Download Access Code does not work. This is why changing the default installer PIN code is important. Changing this code may lock out your control room monitoring service and prevent you from maintaining your system. It is advised you contact your control room before changing this code. Users must have access to the Communicator menu in order to change this setting. This can be programmed in Menus, and assigning the “Advanced” menu. ...C... 117 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 24 Call Back Number 25 Callback Server Communicator Submenus If a telephone number is programmed into this feature, and “Call Back Before Download” is enabled, the system will disconnect for approximately 10 seconds and then call this number. The system does not support pulse dialling. A one second pause is entered by using a P. IMPORTANT: the call back phone number should always be reviewed for accuracy before disconnecting! If an IP address or host name is programmed into this feature, and “Call Back Before Download Session” is enabled, the system will disconnect for approximately 10 seconds and then connect to this IP address. This should be the IP address of the computer where DLX 900 is installed, not the IP address of the system. IMPORTANT: the call back IP address should always be reviewed for accuracy before disconnecting. 26 Number of Rings 27 Number of Calls This contains the number of rings the panel must detect before answering the telephone line when initiating a download session. Answering machine defeat does not need to be enabled. A value of 1 to 15 can be entered in this segment. If this ring count is reached on any individual call, the panel will answer regardless of the call count or number of calls programming. Default = 8 This contains the number of calls the panel must detect before answering the telephone line when initiating a download session. Answering machine defeat does not need to be enabled. A value of 1 to 15 can be entered in this segment. A call is satisfied by one (1) or more rings, and then an eight (8) second period of no ringing. The next call must then be made within 45 seconds. This location stands alone. If it still needed Number of Rings it could be blocked by an answering machine. This will answer on the first ring if the call count is reached. For example: If number of calls is set to 3. And you call the premises and hang up after any number of rings, wait at least 8 seconds, call again and hang up after any number of rings, wait at least 8 seconds, and call again (this is the third call) the panel will answer on the third ring because the call count has reached the Number of Calls programmed value. If on any individual call the number of rings on that call is reached, the panel will answer on that call regardless of the call count. Default = 0, system will pick up the call immediately. 28 Answering Machine Defeat Answering Machine Defeat: Answering machines usually answer calls after a long ring period. The Answering Machine Defeat feature prevents the answering machine from answering the call from the software by making only short rings. If enabled, the system will always answer the call on the second call back. This option is independent of Number of Calls and Number of Rings. ...C... 118 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 29 Download Options Communicator Submenus 1. Call Back Before Download If a download is requested the system will hang up and make a call to the Call Back Number. This is to increase the security of remote access. 2. Lock local Programming Prevents changes to the system system via a keypad. All changes MUST be made using the remote access software. This requires Download Access Code to be enabled. 3. Lock Communicator Programming Prevents local programming of communicator features unless accessed by the Download Access Code. This restricts programming of the communicator. 4. Lock Download Programming Prevents the local programming of the Remote Access Menu without using the Download Access Code. 5. Call Back at Auto Test When an auto test is initiated, perform a Call Back Server or Call Back Number to the number specified. 30 Event Reporting /Channels 31 Event Reporting /Attempts Enter the Channel Group that the system will send system events to. This is the number of times the system will sequence back to the primary channel if the backup channels all fail. This applies to ALL communication attempts including sensor and area events. Example If Channel 1 is the primary, and Channel 2 is the backup for Channel 1, then when both channels fail it will go back to Channel 1. This setting controls how many times the system cycles back to Channel 1 before it gives up. The Channel Attempts setting controls how many times the system stays on the channel before switching to the backup. Always check the max. number of attempts on all channels to avoid unexpectedly high communication charges. ...C... 119 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Communicator Submenus In the diagram below, the system will try Channel 1 3 times, switch to Channel 2 and try 2 times, then go back to Channel 1. This sequence is repeated 2 times in total. In total there will be 10 attempts. ...C... 120 Channel 1 Channel 2 3 tries Channel Attempts = 3 Next Channel = 2 2 tries Channel Attempts = 2 Next Channel = 0 Report Attempts = 2 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.6 Advanced Programming, Schedules Click the Advanced bar and select Schedules from the menu to program schedule options. Schedules Submenus 1 Schedule Number 2 Schedule Name Schedules Submenus The system can support a total of 96 schedules. Each schedule is identified by a unique schedule number, which cannot be altered, and remains as the key reference for each schedule. Each schedule can be configured with a custom 32 character name. The area name is displayed wherever a schedule is referenced on the system. 3 Follow Action Number If an action number is specified, then the schedule becomes enabled when the action is true. When the action becomes false, then the schedule becomes disabled. Schedules can be used to control various parts of the system such as when a user’s permissions are applied. The “Follow Action Number” option allows you to use actions to control schedules. The result is actions can control when permissions are applied, when area types are applied, sensor behaviors, when arm-disarm can occur, and when scenes play. This allows you to create conditional schedules that only become active when certain conditions are met. For example you could create a user that only becomes active (because of the linked schedule) under certain conditions like a fire alarm. ...C... 121 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Follow Action Action controls Schedule Schedules Submenus 4 Times and Days controls Permissions (users and devices) Area Types Sensor Profiles Arm-Disarm Scenes 6 Days / Holidays Up to 16 sets of time and days can be specified here. 5 Start Time / End Time The system handles schedules that span midnight automatically. For example, if a schedule is to cover Fri 8:00pm to Sat 6:00am, only check Friday and the system will automatically manage the time after midnight. Thu Fri Sat Sun If you check Friday and Saturday, the schedule will cover Fri 8:00pm – Sat 6:00am and Sat 8:00pm – Sun 6:00am. Thu Fri Sat Sun Note: Holidays 1-4: If checked, it means the item assigned this schedule will NOT have access during the specified holiday dates. See Advanced Programming,Holidays to program these dates. ...C... 122 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.7 Advanced Programming, Actions The system features powerful automation control which can interact with different parts of the system. It can perform functions based on the status of one or more system conditions. These features are considered advanced programming and should only be changed by an installer with a thorough understanding of the features. Each action has an on and off state. The state is controlled by up to 4 conditions called Action Events, each of which can have a range of items: Action Event Sequence Event 1 and or Event 2 and or Event 3 and or Event 4 = Action State (trigger) + Action Result When all 4 Action Events are met, then the Action State (trigger) will be set. The Action State can be monitored by the system, Schedules, Devices with outputs, and Scenes to activate/deactivate. For example, a strobe connected to Output 2 can be programmed to follow Areas 1 – 8 being armed. Strobe Action Sequence Areas 1 – 8 All Armed = Action 1 True + Activate Strobe Each Action can also directly control selected parts of your system when all 4 Action Events are met. This is called the Action Result. Its behavior also follows the Action State. For example, when all areas are armed and there is activity on Sensor 1, activate a camera recording. Camera Action Sequence Areas 1 – 8 Armed and Sensor 1 Faulted = Action 1 True + Activate Camera Click the Advanced bar and select Actions from the menu to program actions options. ...C... 123 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Actions Submenus 1 Action Number 2 Action Name Actions Submenus Each Action can be configured with a custom 32 character name. The name is displayed wherever an Action is referenced on the system. 3 Function Timed – The action state turns on for the time specified. Follow (Recommended) – The action state turns on once the Event conditions have been satisfied, then off once the Event conditions are not true. On Delay – The action state becomes on after the programmed time period unless the logic result is no longer active. The system can support a total of 256 Actions. Each Off Delay – Follows the result of the logic equation, but remains active for the time Action is identified by a unique number, which cannot programmed after the logic result is no longer be altered, and remains as the key reference for each active. Action. On Pulse – Action state turns on for the Note: All actions are pre-programmed with the programmed time or the active period of the specified trigger. To create a new action, you need to logic result, whichever is the SHORTEST. modify one of these actions. Latch – The action state stays on once the Event conditions have been satisfied. ...C... 124 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Actions Submenus 4 Duration: Minutes 5 Duration: Seconds Where the Function requires duration, this determines, in minutes, how long the action should stay on. Where the Function requires duration, this determines, in seconds, how long the action should stay on. 6 Event(s) 1-4 and Results 7 Event Attributes 8 Event Category 9 Event Type Select the category of the first event. This will determine what events you can select in Event Type. See the Action Events Category and Action Event Types table in Section A.10 for reference. Select the event that you want the Action to monitor. See the Action Events Category and Action Event Types table in Section A.10 for reference. ...C... 125 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 10 Event Start Range 11 Event End Range Select the starting number of the event that you want the Action to monitor. This is related to a number range. For example this might be the first area or sensor number. Select the ending number of the event that you want the Action to monitor. This is related to a number range. For example this might be the last area or sensor number. Actions Submenus If you just want to monitor one item, then leave it at the default of zero, or enter the same number as Event Start Range. 12 Event Combination Logic The logic condition to apply to Event 1 • • • • • OR Inverted OR AND Inverted AND RESET e.g. Area 1 Armed Away OR Area 2 Armed Away e.g. NOT Sensor 1 Bypass OR Sensor 2 Bypass e.g. Area 1 Armed Away AND Area 2 Armed Away e.g. NOT Sensor 1 Bypass AND Sensor 2 Bypass Reset any latched event The Combination Logic selected for each event places the logic prior to the event in an equation. Selecting the AND logic closes a parenthesis for the previous event. The DLX 900 software displays an Event Equation field to make it easier to construct Actions. For example: Event 1 Inverted OR, Event 2 OR, Event 3 AND, Event 4 OR produces a logic equation of: (NOT Event 1 OR Event 2) AND (Event 3 OR Event 4) ...C... 126 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 14 Result Category 13 Result Result Category: The category of the Action Result to perform. Actions Submenus The system can also perform an additional function once the Action Event conditions are satisfied. This is called an Action Result. See the Action Results Category and Action Results Event Types table in Section A.11 for reference. For example, when a fire alarm is active, you could disable Users 1-50 to prevent them from being able to control the alarm system. 16 Result Start Range 15 Result Type Select the starting number of the event that you want the Action Result to affect. The event of the Action Result to perform See the Action Results Category and Action Results Event Types table in Section A.11 for reference. 17 Result End Range 18 Result User Number Select the ending number of the event that you want the Action Result to affect. Select the User that you want the Action Result to behave as. This will apply this user’s full permissions to the Action Result you select. ...C... 127 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.8 Advanced Programming, Auto Arm-Disarm Advanced Arm-Disarm programming allows the system to automate arming and disarming according to a specified schedule. Click the Advanced bar and select Arm-Disarm from the menu to program arm-disarm options. Arm-Disarm Submenus Arm-Disarm Submenus 1 Name 2 User Number Each scenario can be configured with a custom 32 character name. The name is displayed wherever an Arm-Disarm scenario is referenced on the system. The user number that will perform the ArmDisarm. The user’s schedule and permissions will be checked and applied to all areas in the user’s arm or disarm area group at the time of the ArmDisarm. 3 Schedule Number The system can support a total of 32 automated Arm-Disarm scenarios. Each scenario is identified by a unique number, which cannot be altered, and remains as the key reference for each function. The schedule number specified here determines when the arm and disarm is performed by the user number. The starting date/time of the schedule will perform a disarm, the ending date/time of the schedule will arm ...C... 128 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. When a Schedule becomes valid (inside valid time sensor) the system will disarm all Areas that are in the User’s - Active Profile - Disarm Area Group. When the Schedule becomes invalid (out of time sensor) then the system will arm all areas that are in the User’s - Active Profile - Arm Area Group. For example if we had Schedule 4 Mon-Fri 9am-5pm, and User 55 with permission to arm and disarm area 1, 2, and 3, plus their schedule was 24 hours 7 days a week. Then each weekday at 9am the system would disarm areas 1, 2, and 3 as if it were user 55. At 5pm each weekday the system would arm areas 1, 2, and 3 as if it were user 55. Arm-Disarm Submenus Arm Disarm Number 1 – Arm-Disarm Example Schedule 4 – Office Hours Mon – Fri 9am – 5pm See Schedule to program User 55 – Arm-Disarm User See Users to program Permission 99 – Full Access Arm Area Group 1 1, 2, 3 See Permissions to program Disarm Area Group 1 1, 2, 3 Schedule 1 – Full Access 7 days, 24 hours See Schedule to program For an Arm-Disarm to occur, both the Arm-Disarm schedule here and the User Schedule need to be valid at the time the Arm-Disarm is triggered. The Arm-Disarm Schedule determines what the operation is. The leading edge causes a disarming function and trailing edge causes an arming function. The Users Permissions then determines which areas if any are armed or disarmed. If the function is to disarm, the Users Disarm Area Groups will be disarmed. If the function is to arm, the Users Arm Area Group will be armed. When the time becomes 9am, the ArmDisarm tries to disarm all areas using User 55 and their permissions, this includes checking User 55’s schedule. When the time becomes 5pm, the Arm-Disarm tries to arm all areas using User 55 and their permissions, this includes checking User 55’s schedule . Arm-Disarm Schedule 9am-5pm 9am 5pm More complex interactions with the system are possible by modifying the schedule selected here, the schedule assigned to the user, and even combining actions to control schedules. Also, user permissions can have up to 4 permission and schedule pairs. ...C... 129 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.9 Advanced Programming, Devices and Enrollment Click the Advanced bar and select Devices from the menu to program device options. This menu allows you to program devices connected to the system. 6.9.1 System Devices Select System Devices to program and enroll devices including CPU (Control), keypads, zone expansion modules, relay expansion modules and smart power supplies. ...C... 130 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.9.1.1 Control Devices Control Devices are currently limited to the CPU. Use this section to view the CPU serial number, configure the name and view device information such as firmware and hardware revisions. You can also program the 5 on-board CPU outputs, perform enrollment functions and view the current system device counts. Devices Submenus Devices, Control 1 System Devices Control 2 System Devices Control Device Number Select Control. Select among control devices to program them. 3 Device UID 4 Control Name Serial number of the CPU. The name of the system. ...C... 131 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5 Control Info 6 Control Output 1 The system has 5 on-board control outputs. While some are defaulted to drive specific outputs, all of them are programmable via actions. See the following section detailing each control output. Version information about the system including firmware, voice, web, and MAC address. Devices, Control 6.9.1.1.1 Control Outputs Control Output 1 – on terminal J7 Three modes of operation: 1. Defaulted as a siren driver that follows an alarm (DC output). 1a) Terminal OP1+SR supplies 13.8 VDC. 1b)Terminal OP1-SR provides ground when activated (via alarm or action). 1c) This is an open circuit when not activated 2. Configurable for speaker driver that follows alarm (sinusoidal output). 2a) Advanced\System\Siren Options: “Voltage Siren Output” Off = speaker On = DC siren 3. Configurable as programmable output via actions. This line is supervised only if set up as a speaker or DC siren output. Supervison does not require an EOL resistor when a speaker is connected. Line is not supervised if configured as output via Actions. An external tamper input (Tamp2) is available on the terminal strip to support an external enclosure. To enable this opion, go to: Advanced – System – Siren Options – Siren Box Tamper (View page) Speakers: 15 or 30 watts Speaker current draw for allowed Ohm rating, typical: 4Ω – 490 mA (max load, do not exceed this current draw) 8Ω – 230 mA “ 16Ω – 138 mA “ Note: Current draw must be accounted for in your power budget calculations. Control Output 2 – on terminal J7 Two modes of operation: 1. Default operates as a Strobe driver that follows alarm (DC output only). Timing configured in Advanced – System Timers – Strobe Time (View Page) 2. Configurable as programmable output via actions. Terminal OP2+ST supplies 13.8 VDC. Terminal OP2-ST provides ground when activated (via alarm or action). This is an open circuit when not activated. Note: Current draw must be accounted for in your power budget calculations. ...C... 132 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Control Output 3 – on terminal J10 Two modes of operation: 1. Default operates as a Piezo driver that follows alarm (DC output only). Configurable for DC Siren that follows alarm (DC output, same as Output 1). No option for Speaker operation. 2. Configurable as programmable output via actions. POS terminal on J10 supplying 13.8 VDC is shared with output 4. OP3- provides ground when activated (via alarm or action). Note: Current draw must be accounted for in your power budget calculations. Control Output 4 – on terminal J10 Disabled by default. Three modes of operation: Devices, Control 1. For 2-wire smoke detectors, mark the check box to enable in: Advanced – System – General Options (View page) Configure Sensor 8 Type as Fire Alarm Configure Sensor 8 Sensor Options as Fire Note: The system uses Zone 8 for two wire smoke. Zone 8 will be unavailable for use. Limit of xx smoke detectors, future content Note: Current draw must be accounted for in your power budget calculations. 2. For 4-wire smoke detectors, enable in: Advanced – Devices – System Devices – Control (View page) Select Control Output 4 to program Select Action Assignment Select Action 14, Smoke Power in drop down menu (View page) Set output to invert Wire detectors to any zone. Configure Sensor Type as Fire Alarm Configure Sensor Sensor Options as Fire The number of smoke detectors is limited by the capacity of the system’s power supply. Multiple outputs can be used to increase the detector capacity. Note: Current draw must be accounted for in your power budget calculations. 3. Configurable as programmable output via actions. POS terminal on J10 supplying 13.8 VDC is shared with output 3. OP4- provides ground when activated (via alarm or action). Note: Current draw must be accounted for in your power budget calculations. Control Output 5 – on terminal J19 Disabled by default. Programmable via Actions only. Shared terminal with COM for zones 7 and 8. If utilized for output Zone 7 and 8 must be wired to separate COM terminal. POS terminal on J19 supplyies 13.8 VDC. Note: Current draw must be accounted for in your power budget calculations. ...C... 133 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. D e v i c e s , C o n t r o l Devices, Control 7 Control Output, Output Name 8 Control Output, Action Assignment Each output can be configured with a custom 32 character name. The output will activate while the selected action state is true. If the action state becomes false then the output will deactivate. 9 Control Output, Schedule Number 10 Control Output, Invert Invert the Output (normally not used) If a schedule is entered here then the output will only be active when the schedule is valid. If no schedule is entered then the output will always function. ...C... 134 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.9.1.1.2 Enrollment 11 Enroll Function This menu allows you to add new devices to the system. Devices, Control Inactive means no enrollment is active on the system. Automatic Enroll (Automatic enrollment can also be initiated by pressing the Enroll button on the CPU) This is recommended in two scenarios: Either 1) when you are first setting up your system or 2) when enrolling one device only. The procedure automatically searches the bus for new connected devices and adds them to the system in this way: st 1 : By first open (available) slot or “position”. This becomes the device number. nd 2 : In order of Unit ID. Example: Add 3 zone expansion modules to a new system. Open slot # 1 2 3 Unit ID # 0101 1234 0101 1235 0102 1234 Unit ID numbers are in numerical order in the first open slots 1-3. Later add 1 more module to your system. The next available slot is (4). Notice that the device in slot 4 has a lower serial number than those in slots 1-3. But it is in order by available slot, which is prioritized over Unit ID. Open slot # 4 Unit ID # 0100 1234 Alternatively, you may automatically enroll connected devices by holding down the S1 button on the main panel for 3 seconds. The S1 LED (D5) will blink slowly to indicate automatic enrollment is in progress. Confirmation messages also appear on the keypad. When the LED stops flashing then the enrollment function has finished. The system also assigns each device its correct device type. Example system with multiple devices: Device # Device # Device # ...C... 135 P/N 466-5261 • REV D ISS 17NOV17 Control Devices Keypads Zone Expanders Relay Expanders 1 1 1 1 2 2 2 3 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Manual Enrollment Devices, Control Option 1: Select Manual Enroll from the drop down menu. Then click Save. This puts system into manual enrollment mode and waits for you to push the ENROLL button on the Expansion Module/device you want to enroll. The benefit of manual enrollment is that you can control the sequence and device numbering during enrollment. Simply push the Enroll button on the device to be enrolled after the Manual Enroll mode has been enabled on the CPU. Option 2: This option requires the user manually enter the device Unit ID into the server. Go to: Advanced – Devices – System Devices (View page) Select the type of device you are enrolling: (Keypad – Zone Expander – Relay Expander) Select the next available device number. Click device UID. Enter the device Unit ID in the form field and click Save. The device is now enrolled in the system. Note: You have 5 minutes to manually enroll devices before the system exits back into normal mode. When the manual enrollment function is running, the bus will be disabled and no feature that requires access to the main panel will work. This includes arming or disarming of areas. Note: You can change the device number using the management software, DLX 900 Cancel Enroll will stop the manual enrollment mode when you click Save. Replacing Devices In the event of a physical device failure, a new device can be added to the system without the need to enroll and reprogram the device settings. To replace a system device go to: Advanced – Devices – System Devices Select the type of device you are deleting: (Keypad – Zone Expander – Relay Expander) Select the device number of the device you are replacing. Click Device Unique ID (UID). Enter the new device’s UID that is printed on the product label into the form field and click Save. ...C... 136 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Deleting Devices Delete All Devices removes all expansion modules/devices from the system bus when you click Save. Manually Delete Individual Devices To manually delete system devices go to: Advanced – Devices – System Devices Select the type of device you are deleting: (Keypad – Zone Expander – Relay Expander) Select the device number of the device you are deleting. Click Device Unique ID (UID). Scenario 1 Clear the Device Unique ID (UID) from the form field, or enter “0” and click Save. This causes all of the remaining devices to shift up in slot or “position” to fill the newly cleared slot. Devices, Control Scenario 2 Clear the Device Unique ID (UID) from the form field, then enter “1” and click Save. This holds that slot until the next auto enrollment. This becomes an available position. Auto enrollment fills the first available position. Scenario 3 Clear the Device Unique ID (UID) from the form field, then enter “2” and click Save. This permanently holds that position until a new Unit ID is entered for this position, (filled manually only). Auto enrollment does not fill this position; rather it fills the next open position at the end of the list. Deletion example: Device 2 needs replacement and is being deleted, with three different scenarios. Original Device List Scenario 1 result 1 2 Scenario 2 result Clear field, type “1” held* 1 Clear field, type “0” Scenario 3 result Clear field, type “2” held† 1 2 1 3 3 2 2 4 4 3 3 5 5 4 4 6 open 5 5 open open open open†† * Slot held until the next auto enrollment. This becomes the first available position that auto enrollment fills. † Slot held for manual enrollment only. †† Auto enrollment would fill this next open position at the end of the list. 12 Enroll State 13 Device Count Read only field, this is the current state of the CPU. When accessing remotely for programming this area reports back the state of the CPU. 0 = Inactive 1 = Auto Enrollment 2 = Manual Enrollment This displays the number of additional keypads, zone expanders, and relay expanders currently enrolled on the system. ...C... 137 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.9.1.2 Keypads Keypad details as well as several selections for customizing the keypad operation are available in these submenus. Devices, Keypads 14 Keypad Keypad enrollment using the automated enrollment process is best achieved by connecting one keypad at a time. Use the manual process if multiple keypads are connected. It is recommended to enroll 1 keypad in the system initially. This allows you to retrieve the system’s IP address (or set it if DHCP not enabled in the router), which in turn allows access to the GUI for manually enrolling additional devices. 15 Device Unique ID (UID) 16 Name Unique ID number of the keypad. Name of the keypad. ...C... 138 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 17 Keypad Details 18 Custom Message D e v i c e s , K e y p a d Devices, Keypad A custom message of up to 16 characters an be entered here. Information about the keypad including firmware, hardware versions, etc. 19 Keypad Options 20 Permission 1 Permission 1 is the first permission applied, and checked against, when using the selected keypad. See Section 7.3, Permissions for details. Tamper: Enable the rear wall tamper switch on the keypad. Stay Button: Enable the Stay button to appear on the main screen, when this is set to N (disabled) it is also called “Commercial Mode”. Quick Chime: Turn global chime on for partitions the keypad and user have permission to access. Idle PIN: Require a valid user PIN to be entered to exit screen saver mode. Silent Keypad: Disable keypad sounds. 24H Format: Display the time in 24:00 format. 21 Schedule 1 Schedule 1 refers to when Permission 1 is applied. 22 Permission 2 23 Schedule 2 Permission 2 is the second permission applied, and checked against, when using the selected keypad. See Section 7.3, Permissions for details. Schedule 2 refers to when Permission 2 is applied. ...C... 139 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Devices, Keypad 24 LCD (0-1) 25 LCD Level (1-17) Sets the display mode of the keypad. Do not change this value if the keypad display is working correctly. Sets the normal brightness level of the keypad, 26 Idle LCD level (0-17) 27 Idle Timer (10-240) Sets the idle mode brightness of the keypad when it has not been used. This reduces power consumption and glare. Sets the screen timeout when not used, and dims the screen from LCD Level to Idle LCD Level. 28 Keypress Volume 29 Entry Exit Volume Sets the beep volume when the keys are pressed. Sets the volume of the warning beeps used during entry and exit delays. 30 Alarm Volume 31 Language Sets the alarm volume. Enter the language code to set the default language of the keypad interface. Only select languages will be available depending on your region. See below. Language Code 0 1 2 3 4 5 ...C... 140 Language English (U.S.) English (Australia) English (U.K.) German Dutch Dutch (Belgium) P/N 466-5261 • REV D ISS 17NOV17 Language Code 6 7 8 9 10 11 UltraSync Modular Hub Reference Manual Language French (Belgium) French Italian Spanish Portuguese Greek ©2016 United Technologies Corporation .. I ... .. . .. 6.9.1.3 Zone and Wireless Expansion Modules Zone and wireless expansion modules must be enrolled into the system then programmed for proper operation to be achieved. This section details the programming of these devices after they have been enrolled. Note that it is only required to program the hardwired zones on the wireless expansion module if you elect to utilize them. It is not required to program the start and end zone for the wireless sensors. Care must be taken to not learn a wireless sensor into a zone that is programmed as a hardwired input. Wireless sensors currently can be learned in as sensors 1-192 Devices, Zone Expansion Modules 32 Zone Expanders 33 Device Unique ID (UID) 34 Expander Name Unique ID of the zone expander. Name of the zone expander. 35 Expander Details 36 Zone Start and End Details of the expander module. After enrolling a zone or wireless expansion module, its zone range (Start Zone and End Zone) must be programmed. Each module has its own range. The start zone needs to account for CPU zones and other existing modules. (The CPU can be 8 to 16 zones depending on the implementation of zone doubling). 37 Expander Options Default Zone Expander Settings 8 Zone Exp. 20 Zone Exp. Start Zone End Zone If Output Enable is checked, the output operates as the smoke detector reset on 4 wire smoke detectors. Note: If you are working with a Wireless Expander, the Output Enable option is unavailable. ...C... 141 P/N 466-5261 • REV D ISS 17NOV17 9 16 9 28 Not all of the zones of a module need to be used but the zones must be used in order starting at #1 on the module For example: Use a 20 zone module to add 12 zones to an eight zone (CPU only) system. Your Start Zone is # 9. Your End Zone is # 20. You must wire zones 1 – 12 on the expander. There are now 8 unused zones available in the system’s total count of available zones. Note: The default start and end zones for the wireless expander are 0 and 0. This disables the two hardwired zones on the wireless expander. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.9.1.4 Relay Expansion Modules Devices, Output Expansion Modules Relay expansion modules must be enrolled into the system then programmed for proper operation to be achieved. This section details the programming of these devices after they have been enrolled. 38 Relay Expanders 39 Device Unique ID (UID) 40 Expander Name Unque ID (UID) of the relay expander. Name / number of the relay expander. 41 Expander Details 42 Output Program 43 Output Program name 44 Access Function Name of the Output Program. Access cotrol is not supported at this time. ...C... 142 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 45 Schedule 46 Options Invert option is the only option currently available. Sets when the output expander will be used. The Default relay position is NC (normally closed). If the “Invert” tick box is selected when configuring the relay, then the relay will be in the NO (normally open) position (and energized, consuming power). 47 Expander Options This is the physical tamper button on the relay housing. ...C... 143 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.9.1.5 Power Supplies 49 Serial Number Power 48 Device Number Number of the Power Supply. Unique ID (UID) of the Power Supply. 6.9.2 Interlogix Transmitters 51 Serial Number Devices, Interlogix Transmitters 50 Interlogix Transmitters Number of the Interlogix Transmitter. This refers to all wireless sensors and keyfobs. 52 User Serial number of the Interlogix Device 53 Transmitter Options By default all keyfobs are reported as user 999. To enable individual keyfob reporting, assign a user number here. Allows the Installer to configure options for wireless transmitters including: • Tamper • Police • Auxiliary • Disable Supervision • Disable Internal Reed – this applies to transmitters with an internal reed switch • Norm Open External Contact • No Siren on Police 54 Scene On a four-button keyfob, this allows the user to activate a scene when the fourth button is pressed ...C... 144 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Devices, Z-Wave 6.9.3 Z-Wave Devices 55 Z-Wave Devices 56 Z-Wave Devices Name 57 Z-Wave Devices Basic Type 58 Z-Wave Devices Generic Type 59 Z-Wave Devices Specific Type 6.9.4 Tablet Keypads 63 61 Tablet Keypad Name 62 Tablet Serial Number The name of the Tablet Keypad The serial number of the Tablet Keypad 63 Area Group 64 Keypad Options The area the Tablet Keypad is assigned to. ...C... 145 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.10 Advanced Programming, Permissions Click the Advanced bar and select Permissions from the menu to program permissions options. Permissions control what a user or device has access to on the system and what they can do. Permissions Submenus Permissions Submenus 1 Permission Number 2 Permission Name The system can support a total of 128 Permission scenarios. Each scenario is identified by a unique number, which cannot be altered, and remains as the key reference for each Permission. Each Permission scenario can be configured with a custom 32 character name. The name is displayed wherever Permissions are referenced on the system. ...C... 146 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Permissions Submenus 3 Control Groups 1. Menu Group This controls what menus the user or device can access 6. Man Down Area Group This controls which areas will have man down monitoring. 2. Arm Area Group This controls which areas can be armed. 7. Guard Tour Area Group This controls which areas are a part of the guard tour. 3. Disarm Area Group This controls which areas can be disarmed. 4. Reset Only Area Group This controls which areas can be reset only. For example, if a guard is present on the site you may not want them to be able to disarm any areas. By assigning them a Reset Only Area Group, they can turn off alarms, but they cannot accidentally disarm an area. 5. Timed Disarm Area Group This controls which areas can be timed disarm. ...C... 147 P/N 466-5261 • REV D ISS 17NOV17 8. Area Display Group This controls what areas can display area status. 9. Report Channel Group This controls what channels the user can modify. 10. Stay Arm Area Group This controls what areas can be stay armed. 11. Action Group This controls what actions can be displayed or accessed. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Permissions Submenus 4 Permission Options 1. Display Area List - When this feature is enabled on a multi-area system and a user requests to arm/disarm from the main screen of the keypad, the keypad will display the area control screen that will allow them to arm individual areas. If this feature is disabled, the keypad will automatically arm/disarm all areas. This operation applies to Custom user types. You can enable or disable this feature for non-Custom users in the Users Menu. 8. Disarm Action Trigger - When enabled, this users will trigger the Action trigger event “User Disarm Trigger” when disarming an area, used in conjunction with for programming actions. 2. Remote Access - Enables and disables remote web access to the permission. If this is not enabled, a user will not be able to access the web interface directly or via a smartphone app. 10. Report Arm/Disarm - Where a system is already configured to send Arm-Disarm reports this option allows a user to NOT send a report. When enabled the reports will be sent. When disabled reports will not be sent. 3. Duress Code - designates this user as a duress code, whenever this code is used a duress message is sent. 11. Report Arm-Disarm Exceptions – Report Arm-Disarm Exceptions = ON: 4. Reset System Alarms - when System Option System Alarm Latch is enabled, system alarms include panel box tamper can only be reset by a user with this permission. Users without this permission will be able to arm and disarm areas as normal, but system alarms will stay latched. 5. Auto Un-Bypass - When enabled, a bypassed sensor will be reset when disarming. When disabled, the Sensor will remain bypassed even after the system has been disarmed. 6. Disarm Area In Alarm - When disabled, this user will not be able to disarm and reset an area in alarm. Even if the user has permission in their Disarm Area Group, this option will override disarm authority. 7. Area Type Override - Applies to non-standard area types 'Time Disarm' 'Man Down' 'Guard Tour'. When set, disables the feature for the user. ...C... 148 P/N 466-5261 • REV D ISS 17NOV17 9. Arm Action Trigger - When enabled, this user will trigger the Action trigger event “User Arm Trigger” when arming an area, used in conjunction with for programming actions. All four reports are sent as appropriate. Early Opening ‘Fail To Open’ and the reset report ‘Late Open’ Early Close ‘Fail To Close’ and the reset report ‘Late Closing’ Report Arm-Disarm Exceptions = OFF: As expected the only reports are the ‘Fail To Open’ and ‘Fail To Close’ reports with their respective resets ‘Late Open’ and ‘Late Close’. Both the ‘Early Open’ and ‘Early Close’ reports were suppressed. ‘Fail To Open’ and the reset report ‘Late Open’ ‘Fail To Close’ and the reset report ‘Late Closing’ See Area Type for more details. 12. Log PIN Use - Log will show "Valid Code Entered" when enabled. Must be enabled to allow actions and scene events to monitor user interaction. Also see how to set up having users trigger scenes in the Activate Event Type List. See Advanced Programming, Scenes. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Permissions Submenus 5 User Timer Options 1. Disarm Time 2. Man Down Time 3. Guard Tour Time These timers apply to a user when allocated this permission and: • the Area Type is set to Timed Disarm, Man Down, or Guard Tour, • is inside Area Type schedule, • and Area Type Override is NOT enabled under Permission Options If the value of the associated timer is zero, then the system will apply a timer of 45min. See Area Type Settings for a more detailed description on these features. ...C... 149 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.11 Advanced Programming, Area Groups Click the Advanced bar and select Area Groups from the menu to program area groups options. The system can support a total of 16 Area Groups. Each Area Group is identified by a unique number, which cannot be altered, and remains as the key reference for each area. When assigned to a user, an Area Group controls what areas the user can see and control. When assigned to a sensor or device, an Area Group determines what Areas that sensor/device will report and display in. Area Groups Submenus Area Groups Submenus 1 Area Group Number 2 Area Group Name The system can support a total of 128 Area Groups. Each Area Group is identified by a unique number, which cannot be altered, and remains as the key reference for each area. Each group can be configured with a custom 32 character name. The name is displayed wherever an Area Group is referenced on the system. 3 Area List Select the areas that should be part of this Area Group. ...C... 150 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.12 Advanced Programming, Menus Click the Advanced bar and select Menus from the menu to program menus options. Menus are assigned to users and devices to control what menus can be accessed. A total of 64 Menus can be configured. Menus Submenus Menus Submenus 1 Menu Number (1 – 64) 2 Menu Name The system can support a total of 64 Menu Groups. Menu Groups are assigned to users and devices to control what menus can be accessed. Each Menu is identified by a unique number, which cannot be altered, and remains as the key reference for each Menu. Each Menu can be configured with a custom 32 character name. The name is displayed wherever a Menu is referenced on the system. 3 Menu Selections ...C... 151 Check each item to give a user access to that menu. For example, checking Labels permits a user with this Menu in their permission to change the text labels (names) of sensors, areas, outputs, etc. P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.13 Advanced Programming, Holidays Click the Advanced bar and select Holidays from the menu to program holidays options. Also reference Section 5.9, Programming Holidays Holidays Submenus 2 Holiday Name Holidays Submenus 1 Holiday Number (1 – 4) The system can support a total of 4 Holiday Sets. Each set can have up to 16 date ranges. Holidays are used as part of Schedules to control access to the system on specified dates. Each holiday can be configured with a custom 32 character name. The name is displayed wherever a Holiday is referenced on the system. 3 Holiday Date Range Select the date range for the Holiday by specifying the start and stop date. A total of 16 ranges can be entered for each Holiday. ...C... 152 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.14 Advanced Programming, Sensor Types Click the Advanced bar and select Sensor Types from the menu to program sensor types options. Sensors can be programmed to be one of 32 different sensor configurations (sensor type profiles). Sensors are fully configurable in the system. These features are considered advanced programming and should only be changed by an installer with a thorough understanding of the features. Sensor type profiles can also change depending on whether the area they are in are armed or disarmed. This provides the ultimate flexibility in panel programming. Sensor Types Submenus Sensor Types Submenus 1 Sensor Type Number (1 – 32) 2 Sensor Type Name The system can support a total of 32 Sensor Types. Each Sensor Type is identified by a unique number, which cannot be altered, and remains as the key reference for each Sensor Type. Each Sensor Type can be configured with a custom 32 character name. The name is displayed wherever a Sensor Type is referenced on the system. ...C... 153 Sensor type profiles can also change depending on whether the areas they are in are armed or disarmed. This provides a new level of flexibility in panel programming. Armed P/N 466-5261 • REV D ISS 17NOV17 Disarmed UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3 Sensor Type Profile / Armed Sensor Attribute This is how the sensor will behave when the area it is in is armed. • • • • • • Sensor Types Submenus • • • • • Disabled – sensor is disabled. Entry 1 – sensor will follow area entry/exit timer 1. Entry 2 – sensor will follow area entry/exit timer 2. Follower – instant alarm type unless an entry sensor is tripped first. Instant – sensor goes into alarm as soon as it is tripped. Trouble Sensor – typically used on fire doors to the exterior of a building. When the system is disarmed they report trouble and sound a buzzer. When the system is armed they are instant burg alarms. Fire – smoke detectors must be wired Normally Open. A short on a fire sensor will create an alarm condition when the system is armed or disarmed. An open will create a Trouble condition that is always reported for this sensor type, regardless of the Sensor Trouble reporting option. Keypad sensor LED is steady for fire condition and flashing for trouble condition. After fire activation, use the keypad to clear & reset fire sensor by pressing Sensor Reset. Holdup delay – when tripped, starts the hold up timer, if the timer is reached then a hold up alarm is sent. Holdup reset – when this sensor is tripped, the hold up timer is stopped. Keyswitch – A momentary key switch can be used to arm/disarm the panel when it is momentarily shorted from a closed condition. Use a 3.3K resister for this sensor type. Or if DEOL monitoring is enabled in System Options, use two 3.3K resistors to allow full line monitoring. Event Only – this sensor only creates an event when tripped and is stored in the event log. Siren Attribute Select from these 4 options to control what sound the siren makes when this sensor goes into alarm. • • • • Silent – siren makes no sound Fire – temporal three pulse siren Yelping – siren makes a yelping sound Four Pulse – temporal four pulse siren 4 Sensor Type Profile / Disarmed This is how the sensor will behave when the area it is in is disarmed. • Disabled – sensor is disabled. • Instant – sensor goes into alarm as soon as it is tripped. • Trouble Sensor – typically used on fire doors to the exterior of a building. When the system is disarmed they report trouble and sound a buzzer. When the system is armed they are instant burg alarms. • Fire – smoke detectors must be wired Normally Open. A short on a fire sensor will create an alarm condition when the system is armed or disarmed. An open will create a Trouble condition that is always reported for this sensor type, regardless of the Sensor Trouble reporting option. Keypad sensor LED is steady for fire condition and flashing for trouble condition. After fire activation, use the keypad to clear & reset fire sensor by pressing Sensor Reset. • Holdup delay – when tripped, starts the hold up timer, if the timer is reached then a hold up alarm is sent. • Holdup reset – when this sensor is tripped, the hold up timer is stopped. • Keyswitch – A momentary key switch can be used to arm/disarm the panel when it is momentarily shorted from a closed condition. Use a 3.3K resister for this sensor type. Or if DEOL monitoring is enabled in System Options, use two 3.3K resistors to allow full line monitoring. • Event Only – this sensor only creates an event when tripped and is stored in the event log. Siren Attribute See descriptions above. This is how the siren will behave when the area it is in is disarmed. ...C... 154 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Sensor Types Submenus 5 Sensor Attribute Options (Armed or Disarmed) • Keypad Sounder – If enabled, the panel will announce alarm, tamper, or trouble conditions. Default is on. • Report Delay – if enabled, the system will delay reporting sensor activations until the next scheduled report. This setting is ignored if the sensor is a Fire type and sensor activations are reported immediately. When disabled sensor activations (trip, bypass and restorals) are reported immediately. Default is off. • No Keypad Display – if enabled, any sensor conditions such as alarm and tamper will not illuminate the Alarm Light. Conditions will still report and function as normal. Default is off. • Momentary Switch – if enabled, the sensor will not latch. If it is triggered again then it will send another report immediately. Default is off. • Sensor Inhibit (Bypass) – This feature is designed to reduce false alarms at arming/disarming. If enabled, a sensor that is currently faulted that could cause an alarm condition will be temporarily bypassed when changing armed states. This typically occurs when forced arming and the sensor is open, or when a schedule change occurs that changes the sensor type. The bypass will be applied to the sensor if it remains open at the end of the exit timer. Default is off. • Swinger Shutdown Swinger Shutdown is a false alarm prevention feature that counts the number of alarms caused by a specific sensor. ...C... 155 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Sensor Types Table No Keypad Display Momentary Switch Sensor Inhibit (Bypass) Swinger Shutdown Instant Yelping Y Y N N N Y 2 24 Hour Audible Instant Yelping Y Y N N N Y 3 Entry Exit Delay 1 Entry 1 Yelping Y Y N N N Y 4 Entry Exit Delay 2 Entry 2 Yelping Y Y N N N Y 5 Follower Follower Yelping Y Y N N N Y 6 Instant Instant Yelping Y Y N N N Y 7 24 Hour Silent Instant Silent N Y N N N Y 8 Fire Alarm Fire Fire Y N N N N N 9 Entry Exit Delay 1 Auto-Bypass Entry 1 Yelping Y Y N N Y Y 10 Entry Exit Delay 2 Auto-Bypass Entry 2 Yelping Y Y N N Y Y 11 Instant Auto-Bypass Instant Yelping Y Y N N Y Y 12 Event Only Event Only Silent N N Y N N N 13 Momentary Key Switch Keyswitch Silent N N N Y N N 14 Latching Key Switch Keyswitch Silent N N N N N N 15 CO Detector Instant Four Pulse Y N N N N N Siren Attribute Preset Name Keypad Sounder Day Zone Sensor Attribute 1 Preset Number Report delay Note: When initiating Away arming, a sensor with the default sensor attributes of Entry 1, Entry 2 and Follower must be tripped during the exit delay to arm the system in the Away mode. If one of these sensors is not tripped during the exit delay the system will arm in the Stay mode. (CP-01 requirement) Armed Disarmed 1 Day Zone Trouble Sensor Yelping Y N N N N N 2 24 Hour Audible Instant Yelping Y Y N N N Y 3 Entry Exit Delay 1 Event Only Silent N N N N N N 4 Entry Exit Delay 2 Event Only Silent N N N N N N 5 Follower Event Only Silent N N N N N N 6 Instant Event Only Silent N N N N N N 7 24 Hour Silent Instant Silent N Y N N N Y 8 Fire Alarm Fire Fire Y N N N N N 9 Entry Exit Delay 1 Auto-Bypass Event Only Silent N N N N N N 10 Entry Exit Delay 2 Auto-Bypass Event Only Silent N N N N N N 11 Instant Auto-Bypass Event Only Silent N N N N N N 12 Event Only Event Only Silent N N Y N N N 13 Momentary Key Switch Keyswitch Silent N N N Y N N 14 Latching Key Switch Keyswitch Silent N N N N N N 15 CO Detector Instant Four Pulse Y N N N N N ...C... 156 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.15 Advanced Programming, Sensor Options Click the Advanced bar and select Sensor Options from the menu to program sensor options. Sensors are fully configurable in the system. These features are considered advanced programming and should only be changed by an installer with a thorough understanding of the features. Sensor Options Submenus Sensor Options Submenus 1 Sensor Options Number (1 – 32) 2 Sensor Options Name The system can support a total of 32 Sensor Options. Each Sensor Option is identified by a unique number, which cannot be altered, and remains as the key reference for each Sensor Option. Each Sensor Option can be configured with a custom 32 character name. The name is displayed wherever a Sensor Option is referenced on the system. ...C... 157 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Sensor Options Submenus 3 Sensor Options Also see the Sensor Options Table for reference. Bypassed Stay Mode – if enabled, this sensor is automatically bypassed when the area is armed in stay mode. For example, it is an interior sensor. Force Arm Enabled – if enabled, this sensor type may be open while arming if forced arming is enabled in the area options. Normally all sensors in an area must be closed before a user can attempt to arm that area. Bypass – if enabled, this sensor may be bypassed. Cross Zone– This sensor type will require two triggers or another sensor would have to have been trigged before it will activate an alarm. EOL – Enable End Of Line resistor tamper monitoring Automatic Sensor Test – if enabled, this test is controlled by action results automatic test on and off. Night Mode – If enabled, sensor is bypassed in Stay Mode or Instant Stay Mode, and active in Stay Night Mode Sensor Inactivity Test – if enabled, this sensor will check for Sensor Inactivity. The Sensor Inactivity setting must be enabled in General Options. The time is programmed in Advanced Programming, System – System Timers. See Programming the System, Section 5.4. Follow Any Armed Area – If enabled, and a sensor is in more than 1 area it will create an alarm if triggered when any area is armed. If this feature is off then all the areas must be armed before the sensor will become active. ...C... 158 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 4 Sensor Reporting 5 Sensor Contact Options (Applies to the hardwire inputs, not wireless sensors.) • Alarms Reporting – if enabled, this sensor will Sensor Options Submenus • • • • report alarms. Alarm Restores Reporting – if enabled, this sensor will report alarm restores. Bypass-Unbypass Reporting – if enabled, this sensor will report bypasses and unbypass restorals. Sensor Lost-Low Battery Reporting – if enabled, this sensor will report loss of wireless supervision and low battery faults. Sensor Trouble and Restore – if enabled, this sensor will report sensor trouble and restorals. Fire type sensors will always report regardless of this option. • Normally Open – if enabled, the sensor circuit is normally open. Default is off. • Fast Loop – if enabled, the system will be more sensitive and respond quicker to a change in state to the sensor. For example, we could enable this on a door contact to trigger the turning on of lights quicker when someone opens the door by using an Action. Depending on the application this may increase the chance of a false alarm if the sensor is used for intrusion detection. 6 Sensor Report Event From the drop down menu, select the CID and SIA event code to report when this sensor is tripped. ...C... 159 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Sensor reporting Trouble and Restore x x x x 132:BA x x x x x x x 134:BA x x x x x x 134:BA x x x x x x 110:FA x x x x x x 120:PA x x x x x x 122:HA x x x x x x x x x x x x 130:BA x x x x x x 151:GA High Temp x x x x x x 158:KA Water Leakage x x x x x x 154:WA 13 Low Temp x x x x x x 159:ZA 14 High Temp x x x x x x 158:KH 15 Fire Alarm Pull Station x x x x x x 110:FA 16 Night Mode x x x x x x x 135:BA 17 Blank x x x x x x x x 130:BA 18 Blank x x x x x x x x 130:BA 19 Blank x x x x x x x x 130:BA 20 Blank x x x x x x x x 130:BA 21 Blank x x x x x x x x 130:BA 22 Blank x x x x x x x x 130:BA 23 Blank x x x x x x x x 130:BA 24 Blank x x x x x x x x 130:BA 25 Blank x x x x x x x x 130:BA 26 Blank x x x x x x x x 130:BA 27 Blank x x x x x x x x 130:BA 28 Blank x x x x x x x x 130:BA 29 Blank x x x x x x x x 130:BA 30 Blank x x x x x x x x 130:BA 31 Blank x x x x x x x x 130:BA 32 Blank x x x x x x x x 130:BA Preset Number Preset Name 3 Bypass – Forced Arm 4 Bypass – Cross Zone 5 Fire x 6 Panic x 7 Silent Panic 8 Normally Open no EOL 9 Normally Closed no EOL 10 Gas Detected 11 12 ...C... 160 x x x P/N 466-5261 • REV D ISS 17NOV17 x x UltraSync Modular Hub Reference Manual x Sensor Report Event Sensor reporting Lost-Low Battery x x Fast Loop Bypass-Unbypass reporting x Bypass Stay Normally Open Alarm restore reporting x 2 Follow Any Armed Area 134:BA Sensor Inactivity Test x Night Mode x Automatic Sensor Test x EOL x Bypass Cross Zone Time x 1 Bypass x Forced Arm Enabled x Bypassed Stay Mode Alarms reporting Sensor Options Table 130:BA ©2016 United Technologies Corporation .. I ... .. . .. 6.16 Advanced Programming, Event Lists Click the Advanced bar and select Event Lists from the menu to program event lists options. Event Lists are monitored by Channels to determine if they should be reported. Only events on a Channel’s associated Event List will be reported. Event Lists Submenus Event Lists Submenus 1 Event List Number (1 – 16) 2 Event List Name The system can support a total of 16 Event Lists. Each Event List is identified by a unique number, which cannot be altered, and remains as the key reference for each Event List. Each Event List can be configured with a custom 32 character name. The name is displayed wherever an Event List is referenced on the system. 3 Event List Select the events that you want to be part of this Event List. If an event message is on an Event List then the Channel will attempt to deliver it. If an event message is not on the Event List assigned to that Channel, it will not attempt delivery even if the message has been sent to it. See how Channel Groups handle event lists in Advanced Programming, Channel Groups. ...C... 161 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.17 Advanced Programming, Channel Groups Click the Advanced bar and select Channel Groups from the menu to program channel groups options. The system provides you powerful and flexible reporting capability through its Channel feature. They are fully configurable to suit your needs by allowing you to specify what events to report to single and multiple destinations, with multiple levels of back up paths. Channel Groups Submenus Channel Groups Submenus 1 Channel Group Number (1 – 16) 2 Channel Group Name The system can support a total of 16 Channel Groups. Each Channel Groups is identified by a unique number, which cannot be altered, and remains as the key reference for each Channel Group. Each group can be configured with a custom 32 character name. The name is displayed wherever an Action Group is referenced on the system. 3 Channel List For each Channel Group, select the Channels where the event should be sent. ...C... 162 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. When a system event occurs, it is routed to the System Event Channel Group (Communicator\System Event Reporting\System Channels). The Channel Group will forward the event to each of the Channels it contains. If the event is on the Channel’s Event List, the Channel will attempt to send the event to the Channel’s destination. Example System Event AC Fail Channel 1 Control Room 1 System Event Reporting Event List = 1 Channel Attempts = 3 Next Channel = 4 Channel Group 1 System sends event to Channel Group Channel 2 Control Room 2 Channel Group 1 Channel Group sends event to every Channel it contains Channel 1 Channel 2 Channel 3 Event List = 1 Next Channel = 5 Channel 3 Email Channel 4 Control Room 1 Event List = 1 Channel Attempts = 3 Next Channel = 0 Channel 5 Control Room 2 Event List = 1 Next Channel = 0 Event List = 2 Next Channel = 0 Event List 1 Critical Event List 2 Informational Alarms Bypass & Restore AC Fail Open & Closes Auto test Channels 1 and 2 will attempt to send the event as AC Fail is on the corresponding Event List. Back up channels 4 and 5 will also attempt to send the event if they are used. Channel 3 will NOT send the event as Event List 2 does not include AC Fail events. If a sensor event or area event is generated, then the event is sent to the Channel Group specified (Area – Channel Group) in the lowest area the sensor belongs to. The Channel Group forwards the event to each of the Channels it contains. Each Channel checks its Event List to determine if the event should be sent. Example Sensor or Area Event Sensor 3 in Alarm Area Group = 1 Sensor sends alarm to area group Area Group 1 Area 1 Area 2 Event sent to lowest area Area 1 Channel Group 1 Area sends event to Channel Group ...C... 163 Channel 4 Control Room 1 Event List = 1 Channel Attempts = 3 Next Channel = 4 Event List = 1 Channel Attempts = 3 Next Channel = 0 Channel checks to see if the event is on its Event List; if yes it will attempt to send, if not it will stop. If it does not succeed after Channel Attempts, it will try sending on the next Channel. Channel 2 Control Room 2 Channel 5 Control Room 2 Event List = 1 Next Channel = 5 Event List = 1 Next Channel = 0 Channel 3 Email Channel Group 1 Channel 1 Channel 2 Channel 3 Channel 1 Control Room 1 Event List = 2 Next Channel = 0 Channel Group sends Event to every Channel It contains P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Customize Reporting Codes The system has the ability to report Ademco Contact I.D. transmissions. Each report in Contact I.D. consists of an event code and the sensor I.D. generating the alarm. Programmed Event Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Contact I.D. Code SIA Event Code Use default code for Sensor Type 110 120 130 131 132 133 134 135 150 121 122 100 123 137 602 151 158 154 140 140 159 158 115 Use default code for Sensor Type FA PA BA BA BA UA BA BA UA HA HA MA PA TA RP GA KA WA QA SA ZA KH FA Description Fire Alarm Panic Alarm Burglary Alarm Perimeter Alarm Interior Alarm 24 Hour (Safe) Entry/Exit Alarm Day/Night Alarm Non Burglary 24 Hour Duress Alarm Silent Panic Auxiliary Alarm Audible Panic Alarm Tamper Alarm Periodic Test Gas Detected High Temp Water Leakage General Alarm General Alarm Low Temp High Temp Fire Alarm Pull Station Customize the code reported by following these steps: 1. Login to the Web Server 2. Press Advanced\Sensor Options. 3. Select the Sensor Options you want to change. 4. Press Sensor Report Event. 5. Select the desired Contact I.D.\SIA Event Code pair from the drop down menu. ...C... 164 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6. Press Save. 7. Press Settings and Sensors should appear. 8. Assign the customized Sensor Options to the Sensor. 9. Press Save. ...C... 165 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Reporting Fixed Codes in Contact I.D. The table below lists the CID event codes sent for the following reports (if enabled). The number in brackets following the event is the number that will be reported as the sensor number if extended Contact I.D. is enabled in the system options. Otherwise sensor ‘0’ will always be reported. If there are no parentheses, the sensor will be reported as ‘0’. Report Contact I.D. Event Manual Test Auto test Open (user number) Close (user number) Cancel (user number) Download Complete Start Program End Program Ground Fault Ground Fault Restore Recent Close (user number) Exit Error (user number) Event Log Full Fail To Communicate Expander Trouble Expander Restore Telephone Fault Telephone Restore Siren Tamper Siren Restore Aux Power Over Current Aux Power Restore Low Battery Low Battery Restore AC Fail AC Restore Box Tamper Box Tamper Restore Panel Tamper Panel Panic Duress Panel Fire Panel Auxiliary RF Sensor Lost (sensor number) RF Sensor Restore (sensor number) Sensor Low Battery (sensor number) Sensor Battery Restore (sensor number) Sensor Trouble (sensor number) Sensor Trouble Restore (sensor number) Sensor Tamper (sensor number) Sensor Tamper Restore (sensor number) Sensor Bypass (sensor number) Bypass Restore (sensor number) Sensor Inactivity Late To Close Forced Door ...C... 166 P/N 466-5261 • REV D ISS 17NOV17 601 602 401 406 412 627 628 310 310 401 457 605 354 333 333 351 351 321 321 312 312 309 309 301 301 137 137 137 120 121 110 100 381 381 384 384 380 380 137 137 570 570 391 454 423 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.18 Advanced Programming, Action Groups Reserved: Future content. 6.19 Advanced Programming, Scenes Click the Advanced bar and select Scenes from the menu to program scenes options. r Scenes Submenus 1 Scene Number (1 – 16) 2 Scene Name Each group can be configured with a custom 32 character name. The name is displayed wherever an Action Group is referenced on the system. Scenes Submenus The system can support a total of 16 Scenes. Each Scene is identified by a unique number, which cannot be altered, and remains the key reference for each Scene. 4 Scene Trigger Type List 3 When Scene Should Work Select the Schedule that controls when this Scene is active. If the current date and time is outside of the selected schedule, then the Scene will not run. Select the event that will trigger the Scene. Note: If you want to trigger a scene with: User PIN entered Turn On By User Turn Off By User you must first enable Log PIN Use. To enable, see Permission Options. ...C... 167 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5 Activate Sensor 6 Scene Results Number/ Device Select which sensor will provide the trigger for the Scene. Each scene can trigger up to 16 scene actions when a certain condition is met. A scene can be triggered manually, through a schedule, or via a system event. These are simplified actions that allow you to control devices on your system. There are two types of Scene Action - Alarm System Action and Z-Wave Device Action. Scenes Submenus 1. Alarm System Action 2. Result Type - The event of the Action Result to perform. Reference the Scene Action and Scene Action Events Types table below. 3. Result Number - Select the area / scene / camera number to control. 1. Z-Wave Device Action To display Z-Wave Action Types you must first learn in a Z-Wave device. The Z-Wave device name will then appear. 2. Device – select the Z-Wave device you want to control. 3. Z-Wave Type 8 Setting 1 – depends on Z-Wave device. May include options such as On, Off, Heat, Cool, Auto, Up, Down, Lock, Unlock. Scene Action Action Event Type Alarm System Action Disabled Sensor Bypass Turn On Away Turn Off Armed Stay Reset AutoArm Timer Armed Away, No Auto Stay Chime On Chime Off Activate Scene Trigger Camera Video Clip The available functions depend on the Z-Wave device(s) installed. Here are some examples: Z-Wave Device Action ...C... 168 P/N 466-5261 • REV D ISS 17NOV17 Disabled On Off Heat Cool Auto Cool Set Point Heat Set Point Lock Unlock UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.20 Advanced Programming, Speech Tokens Reserved: Future content. 6.21 Advanced Programming, Cameras Click the Advanced bar and select Cameras from the menu to program cameras options. Add a Camera Method 2 – Manual Entry 1. 2. 3. 4. Enter a name for the camera. Enter the IP address and MAC address (Submenus 3, 4 below). Press Save. Your camera will now be viewable from the Web Server and UltraSync app. Cameras Submenus Cameras Submenus 1 Camera Number (1-16) 2 Camera Name Assign Camera Number a Name Choose the Camera Number 3 Camera LAN IP Address 4 Camera MAC Address Assign a Camera a LAN IP address Assign a Camera a MAC address Removing a Camera 1. Select the camera you wish to remove. 2. Delete the IP address and MAC address (Submenus 3, 4 above). 3. Press Save. 4. Your camera will no longer be accessible from the system. ...C... 169 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 6.22 Advanced Programming, Network Servers Click the Advanced bar and select Network Servers from the menu to program network server options. The system will establish a secure VPN connection to Network Servers to allow simplified set up and configuration of email reporting and remote access features. The server addresses are pre-programmed and SHOULD NOT be modified unless you are instructed to by technical support staff. Network Servers Submenus Network Servers Submenus 1 Passcode and Servers 2 Web Access Passcode This 8 digit code is required to allow remote access to your system via a smartphone app. Set this to 00000000 to disable this feature. 3 Ethernet Servers (1-4) 4 Cellular Servers Ethernet Server 1 The IP address or server name of the primary Ethernet server. Ethernet Servers 2 - 4 The IP address or server names of the backup Ethernet servers. ...C... 170 P/N 466-5261 • REV D ISS 17NOV17 Cellular Server 1 The IP address or server name of the primary wireless server. Cellular Servers 2 - 4 The IP address or server names of the backup cellular servers. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. ...C... 171 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 7 7 Users and Permissions A user is a system operator that is granted the authority to control and or configure the system. The Users menu is where you add, delete or modify one of the 256 users. Each user is assigned a PIN code and a user number. This allows them to interact with the system. Users will typically interact with the system via a keypad or wireless keyfob(s) for tasks such as arming and disarming an area, bypassing a sensor. Permissions can be granted to a user to perform tasks such as adding sensors, modifying schedules or deleting users. Users can only edit users with the same or less authority than them. If a user attempts to access a user with a higher level of access (e.g. to more menus or more areas) then the system will deny access. 7.1 Add Users Connect to the Web Server. The login screen should appear: Enter your username and password. A master User PIN is required to add users, by default this is “User 1” and “1–2–3–4”, then press Sign In. Press Users. The following screen appears: ...C... 172 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. User Menu: Enter a First and/or Last Name. Enter a unique PIN code between 4 and 8 digits. Select a User Type: Standard users can arm and disarm areas; they cannot create users or review event history. Master users can arm and disarm areas. They can create, delete, or modify user codes. They can also change system settings. Arm Only users can only turn on the security system; they cannot disarm, or dismiss any system conditions. Duress users will send a duress event when they are used to arm or disarm the system. Custom users can have additional permissions and settings configured. Display Area List When this feature is enabled on a multi-area system and this user requests to arm/disarm the system from the main screen of the keypad, the keypad will display the area control screen that will allow them to arm individual areas. If this feature is disabled, the keypad will automatically arm/disarm all areas. Press Save. ...C... 173 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 7.2 Users Submenus The following submenus describe the features associated with the Users Menu. User Submenus User Submenus User First Name Each user can be configured with a custom 16 character first name. The user name descriptor may be displayed in the event log, keypad and when remotely connected to the system via the management software. User Last Name Each user can be configured with a custom 16 character last name. The user name descriptor may be displayed in the event log, keypad and when remotely connected to the system via the management software. User Number The system will store a number of users relative to the model type and the amount of memory installed. Unlike other systems, user numbers are not predefined and can be configured from user number 1 to 1000 as long as user numbers are not duplicated and do not exceed the total number of users that can fit the allocated memory. User PIN Users can be configured with 4 to 8 digit PIN. The user PIN is required by the system to determine the user number and the users associated permissions system control and configuration. Any number of users can have any digit length from 4 to 8 digits. ...C... 174 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. User Type User Submenus User Type provides quick configuration of user permissions. The available user types are: 1. Standard – Standard users can only change their own PIN codes and cannot change the settings of the system. They can arm and disarm areas to which they have access. 2. Master – Master users can change Standard user PIN codes and Master user PIN codes, and can access all menus except installation programming. 3. Arm Only – Users can only arm selected areas. 4. Duress – Duress code will send a duress report to the specified Channel Groups under System Event Reporting. The duress code does not trigger an audible alarm. 5. Custom – The system will apply user permissions and user permission schedules. This requires advanced programming. A Custom user is able to modify the configuration of themselves or another user if: Permission Option ‘Remote Access’ is enabled (for web page access). Permission Menu ‘Users’ is enabled to allow them to assign user permissions. Otherwise they will only be able to change their own PIN code. They have area access to at least one area of the user being modified. This does not check permission options. 7.3 Permissions There are a total 128 unique permissions that can be configured in the Permissions menu. Once configured any permission number from 1 to 128 can be allocated in this feature (user permissions 1). User permissions determine what level of access and functionality a user has when interacting with the system. This includes what menus they can see, what areas they can see, areas they can arm / disarm / reset, perform special area functions of timed disarm / man down / guard tour, what actions they can use, and what channel to report on. Combining a user permission with a user permission schedule will determine when that user has that level of access and functionality. The system allows each user to be allocated with up to 4 user permissions and permission schedules. This provides a high level of flexibility and user permissions can change based on time and date, or even certain system conditions when combined with actions. When any user permission is active, it overrides any user type. This means a permission can increase or decrease access when it is active. If a user is not assigned any permissions (i.e. permission set to “Disabled”), then the User Type setting is used to determine what the user can do. ...C... 175 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Permission Schedule 1 The system’s permission schedules determine when to allocate user permissions to a user. User permissions are numbered from 1 to 4 where permission 1 is the highest priority and permission 4 is the lowest priority. If user permission 1 schedule is not valid then user permission 2, 3 and 4 are checked in sequence until a valid schedule can be applied. Higher priority permissions replace lower priority level permissions when they become active. Only one permission can be active at any time. Permissions have a logic OR function. IMPORTANT: If permission 1 is active due to a valid schedule, permission 2 will never become active. Make sure to assign/program permissions in the right order. Cleaner User Permission 1 = All Areas Permission Schedule 1 – 5-10pm M-F User Permission 1: All Areas 5pm 10pm A cleaner is given access to all areas after hours. They can disarm/arm the security system from 5pm to 10pm on weekdays. They have no access outside of these times and days. Bank Manager User Permission 1 = Bank Vault + Common Areas Permission Schedule 1 – 9-5 M-F User Permission 2 = Common Areas Permission Schedule 1 – 24/7 User Permission 1: Common + Bank Vault User Permission 2: Common Areas 9am 5pm A bank manager has access to the common areas of the bank 24 hours a day. During office hours they have access to the bank vault as well. The permissions to access bank vault become active at 9am, overriding the common areas permission. When the time becomes 5pm the bank vault permissions become inactive and their lower level permissions to access the common areas become active again. IMPORTANT: Only one permission can be active at any one time. User Permission 1 overrides User Permission 2, so ensure User Permission 1 includes all the areas (and other features) you want to give access to. If User Permission 1 only included the Bank Vault, the user would NOT have access to the Common Areas. ...C... 176 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Arm Only Standard Master Engineer Master Engineer Custom User Change their own PIN code X X X X X Custom Arm areas based on permissions X X X X X Custom X X Limited X Custom X Custom X Custom Disarm areas based on permissions Can create and modify Standard users X Program installation settings X Can create and modify Engineer users X Can create custom permissions and schedules X Area Group When a non-Custom User Type is selected, this setting determines what areas that user has access to. When a Custom User Type is selected, permissions will be used instead of this Area Group setting. Start Date The first date when this user can interact with the system. Future start dates can also be set here. The user will only be able to interact with the system between the start date and end date. End Date The last date when this user can interact with the system. Future end dates can also be set here. The user will only be able to interact with the system between the start date and end date. Language Currently English is the only supported language. ...C... 177 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 8 8 Expansion Module Installation These instructions are common to Zone or Relay Expansion Modules 1. Open the alarm panel. 2. Pull down the din rail tab on the bottom of the module. (Pictured: UM-Z8) 3. Hang the module on the top of the din rail, tilting the bottom of the module outward. Once the module is vertical, lock the module on the rail by pushing the tab up. 4. Connect BUS and power off the CPU ...C... 178 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5. Correct RS-485 termination reduces communication issues with signal reflections. For a single long cable run, put a jumper across the terminal labeled TERM on the CPU and the furthest bus device. For installations with multiple long cable runs, do not place a terminator on the CPU; rather place one at the end of each of the two longest cable runs. 6. Enroll the expansion module in your system. To manually enroll the module, use the web interface. In the advanced menu, navigate to Devices – System Devices – Control – Enroll Function and select Manual Enroll from the drop down menu. This puts the system into the manual enrollment mode and waits for you to push the enrollment button on the expansion module. Hold the button down for three seconds. (Pictured: UM-Z8) 7. For enrollment options see Section 6.9, Advanced Programming, Devices and Enrollment 8. When connecting powered sensors you can use the zone expansion module’s POS and COM terminals for power. Powered sensor current draw must be accounted for in your overall system power budget calculations. Refer to the documentation of the powered sensor for current draw specifications. ...C... 179 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 9 9 Cellular Radio Setup An optional cellular radio provides a backup reporting path to the central monitoring station over a cellular network if the Ethernet connection is not working. This module adds mobile communication to the alarm panel, allowing alarm reporting and remote connection over the mobile network via the UltraSync Cloud solution. This provides a plug and play connection to UltraSync servers for secure reporting with no configuration needed in most cases. The only requirement is good mobile device reception. To connect via Cellular Radio you only need to plug in the cellular radio module. The cellular modem is pre-configured and does not require any programming in the system. However, the system must be provisioned in the UltraSync Portal for cellular reporting per the options below: Connectivity Ethernet and Cellular Cellular only Portal Provisioning US Grade 2 dual path US Grade 2 Cellular Once plugged onto the panel, the unit will automatically register itself on the cellular network. Please refer the manual that comes with the cellular radio for instructions on how to install it. 9.1 Install Optional Cellular Radio Note: A SIM card is pre-installed and should not be removed. A mobile device can provide general guidance on mobile network coverage. Look at the signal strength on a mobile device to verify there are 4/5 to 5/5 bars of reception in the location where you will install the system. If the signal strength is low, find another location which has stronger signal strength. Note: Actual signal strength can only be determined logging in to the panel. ...C... 180 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. If a cellular module is pre-installed on the CPU, skip to the Check Network Coverage section. If not, remove the cover by releasing the four (4) side clips with a flat blade screwdriver. Locate the 16-pin header on the main board and insert the board-to-board connector. Remove the 3G module from the packaging. Align the 3G module on the 16-pin header as shown to the left. Push down until the pins come through the header. Take care not to bend the pins. Install the antenna by aligning the connector and pressing down until you hear a “click”. ...C... 181 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Align the smaller cover included with the UM-C-H1 and press down until all four (4) clips lock into place. The original larger cover is no longer of use at this stage. For future reference you may want to peel off the serial number bar code label from the original cover and place it on the smaller cover just installed 9.2 Check Signal Strength This chart illustrates the acceptable signal strength range. If the reported value is -88 to -51 then the signal strength is OK. If the reported value is -121 to -89 then relocate the antenna until the signal strength is in an acceptable range. To check the signal strength using the UltraSync web server or the UltraSync app: Login to the UltraSync Web Server, and click Settings – Connection Status. Scroll down to Signal Strength and check whether Signal Strength is acceptable. Valid Service ...C... 182 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Check cellular connection: a. Look at cell state, it should display Connected. b. Wait until cell state displays Connected, press Reload to refresh the status. c. Check signal strength – signal strength should be between -88 to -51. d. Contact Tech Support for assistance. e. Check that radio is correctly installed and firmly connected. f. Check if antenna is correctly installed or move antenna to a higher location. If you need to make changes, open the UltraSync Web Server and go to: Advanced – Communicator – Cellular configuration: Only change these settings as instructed by your supplier or telecommunications provider. To check the signal strength via the UM-1820E keypad: Press MENU – [PIN code] – Settings – Status – Connection Status. Scroll Right until you see Signal Strength. Check whether Signal Strength is acceptable. ...C... 183 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 9.3 Check cellular connection to UltraSync servers 1. 2. 3. 4. Login to the Web Server as shown above. Click Settings. Select Connection Status in the drop down menu. Check: • UltraSync Status should display “Connected”. • Cell Service should display “Valid service”. • Signal Strength should display a value. See Section 9.2 to Check Signal Strength. If it does not display a signal strength value, check the cellular connection: 1. Check Settings – Network – Enable UltraSync is checked. Alternatively from a keypad press MENU – Program – Communicator – IP Configuration – IP Options – Enable UltraSync: Y. 2. Look at Cell State, it should display “Connected”. Please wait until Cell State displays “Connected”, click Reload to refresh the status. 3. Signal strength should be between -89 to -51. 4. Check cellular radio module is correctly installed. 5. Check cellular radio antenna is correctly installed or move antenna to a new location with better signal strength. Congratulations, your system is connected to UltraSync. It is now ready to be programmed. ...C... 184 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. ...C... 185 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 10 10 UltraSync Touchscreen Setup 10.1 Quick Setup 1. Connect Power Lead to the touchscreen. 2. Connect the micro-USB connector from power supply to the micro-USB port of the touchscreen. power micro USB volume 3. Power up Hold the power button on the touchscreen. The screen will light up. 4. On the first startup, you will see a network error message because the touchscreen is not connected to a Wi Fi network. Press OK. Press the menu button to configure the touchscreen. The touchscreen will ask you for a PIN. ...C... 186 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5. Enter the default installer PIN of the touchscreen, which is 9-7-1-3. Then press Done. 6. Press the settings button. 10.2 Set up Wi Fi 1. Press Wi Fi. 2. Select a Wi Fi network from the list that appears. Press the network you wish to use. !! Note: The touchscreen and hub must be on the same network. !! 3. Type in the network password and press connect. 4. Once connected to Wi Fi, you will be brought back to the main screen.. ...C... 187 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 10.3 Enroll the Touchscreen 1. The touchscreen needs to be enrolled into the UltraSync Hub. Press the menu button and press enroll. 2. The touchscreen will automatically find any available hubs on the network. They appear in the left column. Select the desired hub from the network displayed. Enter the installer PIN that is set up for the hub. Note: This may not be the default 9-7-1-3. 3. Select an available tablet number space (center column). Then select the area group you wish the touchscreen to control (right column). 4. Press the Enroll Tablet button at the bottom of the screen. ...C... 188 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 10.4 Touchscreen Settings Allow Master User to Upgrade Firmware – Enable this feature to allow the Master User to have access to the Upgrade menu. Language – This allows you to select the language the touchscreen displays. Active Brightness – Choose between 1% - 100%. This is the background light level when the user is actively using the touchscreen. Idle Brightness – Choose between 1% - 100%. This is the background light level when the user is not actively using the touchscreen. Setting the level to 1% will make the touchscreen appear black when idle. The user may still touch the screen to make the screen active again. Idle Timeout – Choose between 10 – 300 seconds. This is the amount of time that touchscreen allows the user to be idle before it locks down and requires a PIN to re-enter the touchscreen. Beep Volume – Choose between 1% - 100%. This is the volume level of entry/exit beeps. Camera User Name and Camera Password – If using the touchscreen with cameras, you must enter the camera’s User Name and Password to allow access. 10.5 Mounting 1. Mount the wall bracket in the desired location using the supplies wall anchors and screws. Mounting holes (3) Mounting holes (3) Wall Bracket 2. Notice the mounting tabs; they slide into slots on the back of the tablet. Mounting tabs Mounting tabs Wall Bracket Slide tabs into mounting slots ...C... 189 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3. To remove the tablet from the mounting bracket, use a small screwdriver to push up on the release tab on the bottom of the tablet’s back cover. Release tab 10.6 Upgrading Firmware 1. Always upgrade your touchscreen to the latest firmware during the first startup. 2. If firmware is available, press Download. Wait until the download is complete. Press Install; you will be returned to the main screen 10.7 Other 1. To increase speed and performance, the UltraSync touchscreen communicates with the cameras using the local network. If you have modified the cameras’ usernames or passwords you must enter these updated credentials in the touchscreen. ...C... 190 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. ...C... 191 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 11 11 Camera Setup Instructions 11.1 Quick Setup Note: If the light source where the camera is installed experiences rapid, wide variations in lighting, the camera may not operate as intended. To quickly put the camera into operation: 1. Prepare the mounting surface. 2 Mount the camera using the appropriate fasteners. 3. Connect the camera to the local network via Ethernet cable or Wi Fi.. 4. Learn the camera into the UltraSync App using the “Scan for New Cameras” button discussed in Section 5.10, Camera Configuration. 11.2 Setting up Ethernet/Wi Fi transmission Wi Fi transmission distance The Wi Fi transmission distance/range of the camera is approximately 50 m (164 ft.) in open air applications. Note: The transmission distance may vary due to the presence of physical obstacles, such as trees, walls, elevators, fire doors, furniture, etc. Avoid very solid walls and metallic objects in the transmission path. Other Wi Fi networks (for example Wi Fi, WiMAX) operating on 2.4 GHz and certain types of devices (e.g., microwave oven point-to-point Wi Fi transmission) can cause interference with your network. The result would lead to a reduction in transmission distance/range. Devices Supported For Ad Hoc Installation Apple iOS, PC – Windows XP, 7, 8 Devices NOT Supported For Ad Hoc Installation Android, Windows Mobile, Blackberry ...C... 192 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11.3 Wi Fi Signal Strength Wi Fi signal strength can be checked in the Network section of the TruVision Browser. Use the scale below to measure if actions are needed to improve performance. 85+ – Excellent: No additional actions needed and default video resolutions settings may be increased if desired. 75-85 – Very Good: No additional actions needed to increase signal strength. It is not recommended to increase video resolution settings. 65-75 – Good: It is recommended to use a Wi Fi repeater or Powerline adapter to increase signal strength. Alternatively, video resolutions settings may be reduced to minimize poor video quality. Below 65 – Poor: It is not recommended to use the camera with a signal strength below 65. Video streams will likely not work below this level. A Wi Fi repeater or Powerline adapter should be used to increase signal strength. ...C... 193 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11.4 Add Camera via Wi Fi for iOS Device 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Power up the camera. (Boot up may take 1-2 minutes) From your iOS device, go to Settings, then Wi Fi. Find and select TVW-xxxxx. (Listed under Devices) Once connected, press the info circle on the right of TVW-xxxxx. Under IP Address, press Static and enter the info below. a) IP Address 192.168.1.71 b) Subnet Mask 255.255.255.0 Open Mobile Browser. (Safari) Enter the camera’s default IP Address into the address bar. a) 192.168.1.70 TruVision Configurator will appear. Enter Credentials below. a) User Name: admin b) Password: 1234 Press Configuration on the top menu. Press Network on the left menu. Press Wi Fi on the middle tab. Select your network from the Wireless List. Enter Wi Fi Network Passphrase in Key 1 Section. Press Save on the bottom of the screen. You are now connected to the network via Wi Fi! 11.5 Add Camera via Wi Fi for Windows PC 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Power up the camera. (Boot up may take 1-2 minutes) From your Windows PC, Find and connect to TVW-xxxxx in Wi Fi network list. Go to Network and Sharing Center. Control Panel > Network and Internet > Network and Sharing Center Press Change Adapter Settings on left. Right click Wireless Network Connection and select Properties. Click Internet Protocol Version 4 (TCP/IPv4) and click Properties. Click “Use the following IP address”, enter the info below, and then click OK. a) IP address: 192.168.1.71 b) Subnet mask: 255.255.255.0 Open Browser (Firefox, Chrome, IE8) and enter the camera’s IP Address into the browser’s address bar. a) Camera’s Default IP Address is 192.168.1.70. TruVision Configurator will appear. Enter Credentials below. a) User Name: admin b) Password: 1234 Click Configuration on the top menu. Click Network on the left menu. Click Wi Fi on the middle tab. Select your network from the Wireless List. Enter Wi Fi Network Passphrase in Key 1 Section. Click Save on the bottom of the screen. You are now connected to the network via Wi Fi! ...C... 194 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11.6 Add Camera via Ethernet for iOS Device (non DHCP) 1. 2. 3. 4. 5. Power up the camera. (Boot up may take 1-2 minutes) From your iOS device, go to Settings, then Wi Fi. Find and select TVW-xxxxx. (Listed under Devices) Once connected, press the info circle on the right of TVW-xxxxx. Under IP Address, press Static and enter the info below. a) IP Address 192.168.1.71 b) Subnet Mask 255.255.255.0 6. Open Mobile Browser. (Safari) 7. Enter the camera’s default IP Address into the address bar. a) 192.168.1.70 8. TruVision Configurator will appear. Enter Credentials below. a) User Name: admin b) Password: 1234 9. Press Configuration on the top menu. 10. Press Network on the left menu. 11. Change LAN settings to desired configuration. a) Change the IPv4 Address and IPv4 Subnet Mask to match the router if a static IP Address is desired. i. You must change the static IP address to something different than the default 192.168.1.70 if more than one camera is used on the network. ii. Make sure to use the Test button to validate IP Address is not already assigned to another device in the network. 12. Press Save on the bottom of the screen. You are now connected to the network via Ethernet! ...C... 195 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11.7 Add Camera via Ethernet for Windows PC (non DHCP) 1. 2. 3. Power up the camera. (Boot up may take 1-2 minutes) From your Windows PC, Find and connect to TVW-xxxxx in Wi Fi network list. Go to Network and Sharing Center. Control Panel > Network and Internet > Network and Sharing Center 4. Click Change Adapter Settings on left. 5. Right click Wireless Network Connection and select Properties. 6. Click Internet Protocol Version 4 (TCP/IPv4) and click Properties. 7. Click “Use the following IP address”, enter the info below, and then click OK. a) IP address: 192.168.1.71 b) Subnet mask: 255.255.255.0 8. Open Browser (Firefox, Chrome, IE8) and enter the camera’s IP Address into the browser’s address bar. a) Camera’s Default IP Address is 192.168.1.70. 9. TruVision Configurator will appear. Enter Credentials below. a) User Name: admin b) Password: 1234 10. Click Configuration on the top menu. 11. Click Network on the left menu. 12. Change LAN settings to desired configuration. a) Change the IPv4 Address and IPv4 Subnet Mask to match the router if a static Address is desired. IP i. You must change the static IP address to something different than the default 192.168.1.70 if more than one camera is used on the network. ii. Make sure to use the Test button to validate IP Address is not already assigned to another device in the network. 13. Click Save on the bottom of the screen. You are now connected to the network via Wi Fi! 11.8 Add Camera via Ethernet (DHCP) 1. 2. Power up the camera. (Boot up may take 1-2 minutes) Connect router and camera with Ethernet cable. You are now connected to the network via Ethernet! 11.9 Add Camera to UltraSync Ensure proper installation of camera hardware before proceeding to camera setup. Make sure camera and UltraSecure intrusion panel are on the same local area network. Applications were the Intrusion panels uses cellular only are not compatible with this camera. Note: For detailed information on how to setup the UltraSync app, add locations, and login as an Installer, reference the intrusion panel installation guide. ...C... 196 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Press then for the page. Select Cameras from the drop down menu. Press Scan for New Cameras. “Success!” message will pop-up after a few moments. The scan results in an IP address and MAC address listing in the form fields shown. Make sure the MAC ID that is automatically populated in the MAC Address field matches the MAC Address printed on the back of the camera. If not, change in the MAC Address to the one listed on the back of the Camera. Press Save. Note: Camera may take up to 1-2 minutes to finalize association with intrusion panel and show in cameras tab. CONGRATULATIONS! You have now added the camera to UltraSync! ...C... 197 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11.10 View Live Stream and Latest Clip Press tab on bottom of the screen. All available cameras will be shown. Press to view a live feed of a specific camera. Press to view the last recorded clip from a specific camera. 11.11 Program Event Triggered Camera Clips Cameras can be programmed to automatically record when selected events occur. This is achieved by creating a scene. Press then for the page. Select Automation (Scenes) from the drop down menu. 1. Select the Scene to Configure and type Scene Name. 2. Select the When Should Scene Work drop down menu to restrict when the scene will be enabled. ...C... 198 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3. Select the event that will trigger the automation using the Scene Trigger Type drop down menu. Choices here dynamically change the “Activate” selections. 4. Select Activate ( - - - - ) to assign what that triggers applies to. 5. Select the Scene Result. Choose Alarm System in Device. 6. In Action Type, select Trigger Camera Video Clip 7. Press Save. Clips are recorded on the Micro SD card installed in the camera and are linked to events in History. See the following page to see how to view event triggered clips. ...C... 199 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11.12 View event triggered clips in History Press on bottom of the screen. Press Find the Event you wish to view using Oldest, Prev, Next, and Latest buttons. Once you find the clip you wish to view, press Play Video Clip. 11.13 Remove Camera from UltraSync (if needed) 1. 2. 3. 4. 5. 6. Press the More tab on the bottom of the Screen. Press Settings. Select Cameras under Settings Selector. Select the camera you with to remove. Delete text in Camera Name, IP Address and MAC Address. Press Save. Remove All Cameras Shortcut: To remove all cameras from UltraSync, go to Advanced Settings and use SHORTCUT 910.22. Reset Camera to Factory Default (if needed) If needed, the camera can be reset to factory default. Remove the camera cover, then press and hold the RST/WPS button for 20 Seconds. 11.14 Change Default Camera Settings (Via TruVision Navigator) 1. From a computer or mobile device that is connected on the same network as the camera, type in the IP address of the camera into the devices browser. 2. Login using default login. a. Login: admin b. Password: 1234 3. Change settings as desired such as video quality, frame rate, pre and post recording times. 4. For detailed instructions on using TruVision Navigator, go to www.interlogix.com/video. ...C... 200 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 11.15 Camera Troubleshooting 1. Camera is not showing in list of Wi Fi networks. Cause Solution The camera takes up to 90 seconds to boot up. It will not show in Wi Fi Networks until this is complete. The camera has previously been setup and ad hoc mode was turned off. Perform a factory reset to broadcast the camera again. Certain mobile devices do not support ad hoc mode. iOS and Windows devices are known to support ad hoc, Android and Windows Mobile devices typically do not support ad hoc mode. If your device does not support ad hoc mode, install the camera using a Windows PC. 2. The camera does not add to the UltraSync network when I perform the “Scan for Cameras” Function Cause Solution Older firmware versions do not support cameras. Make sure your panel is updated to the XXXXXX-04 Firmware or new. The camera will not work if the devices are not on the same network. Make sure your camera and system are on the same network. The system must be using IP to work with the cameras. Make sure your system is not installed using a cellular radio only. Make sure you are not adding cameras on a network that already has a high number of cameras installed on the same network. This is unusual, but may be common in testing environments. Put the system and the cameras on their own router and this should solve the problem. 3. The camera was added in the setup process, but the video doesn’t show in the Cameras tab. Cause Solution Wait for the process to complete After completing the setup process, the camera may take up to 2 minutes to full sync and show in the UltraSync App. Make sure your camera is still connected to the network. If video still doesn’t show, go back into setup and perform the “Scan for Cameras” function again. 4. Live Video isn’t giving good quality. It is choppy, shows gray, etc. Cause Solution Check to make sure your camera’s Wi Fi and/or Ethernet connection speeds are not poor. If Wi Fi connection speeds are poor. It is recommended to use a Wi Fi repeater to increase signal strength. The cameras default settings are setup to work on a strong home network. In some cases, low video settings may be required to achieve a smooth video. Use the TruVision Browser to change the cameras video settings. 5. Video Clips take a long time to load. Cause Solution The cameras default settings are setup to have video clips start playing in the UltraSync App within 15 seconds (On a strong network). If default settings were changed to longer clip times or higher video quality, the amount of time needed to pull the clip will be higher. Lower the quality or length of clips to shorten load times. ...C... 201 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 12 12 Arming and Disarming the System Only users with an authorized PIN code (Master/Standard Users) will be allowed to use the alarm system. 12.1 Keypress Tamper Disabled by default When the Enable Idle PIN feature is active, the UM-1820E keypad will be locked in screensaver mode when unused for a preset time. A valid PIN is required to unlock the screen and access the system. When an incorrect PIN is entered 3 times the keypad is locked for 80 +/- 5 seconds and the screen will display a lock icon. During this time the keypad will not be operational and PIN codes cannot be entered. After the 80 +/- 5 seconds expires, if the first PIN attempt is incorrect the 80 +/- 5 second timer will start again. If the PIN code is valid, then the counter will reset and a further 2 attempts can be accepted. 12.2 Arm Your System in Away Mode Touch the Away or Away + button to arm your system in Away mode: If your system has multi-Area control enabled, the Away + button will be displayed. A valid PIN code will need to be entered to determine what permissions they have, this includes which Areas and at what time/day that user has access. 12.3 Arm Your System in Stay Mode Touch the Stay or Stay + button to arm your system in Away mode: If your system has multi-Area control enabled, the Stay + button will be displayed. A valid PIN code will need to be entered to determine what permissions they have, this includes which Areas and at what time/day that user has access. ...C... 202 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 12.4 Disarm One or More Areas Touch the Off or Off + button to arm your system in Away mode: If your system has multi-Area control enabled, the Off + button will be displayed. A valid PIN code will need to be entered to determine what permissions they have, this includes which Areas and at what time/day that user has access. 12.5 Activate SOS Feature SOS functionality is enabled by default. See Areas Programming and the instructions in Programming Areas. Touch the SOS button to display the SOS feature: On this screen touch and hold the appropriate button for 2 seconds to activate Manual Fire Alarm, Manual Auxiliary Alarm, or Manual Panic Alarm. Depending on how your system is programmed, the control room may receive the corresponding event. Check with your control room to determine what action will be taken. If silent alarm is enabled, then the keypad will not display any signs that the panic button was pressed. To cancel a SOS alarm – return to the home screen, touch the Status button and turn the Area off. ...C... 203 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE 13 13 Glossary Action An action allows the system to perform automation functions. These can monitor the status up to 4 input conditions called Action Events, change state (Action State), and perform a function (Action Result) such as arming a range of areas. Action Group An action group is one or more actions that can be accessed by a device or user. They are assigned to a user or device via permissions. Area Sensors are grouped in to areas which can be secured independently from each other. This allows you to split your security system in to smaller components that can be separately managed. For example your system can be divided into an upstairs area and downstairs area. Area Group Arm Arm-Disarm An area group is one or more areas that can be accessed by a device or user. They are assigned to a user or device via permissions. To turn your security system On. Automatically arm and disarm areas by a specific user according to a specified schedule. The areas armed and disarmed will be the ones that the user has access to via their permissions. Away Mode To turn your security system on when you are leaving the premises. Bypass Sensors can be temporarily disabled so they will not be monitored by the security system. For example, an interior door is left open, bypass it to temporarily ignore it and allow arming of the security system. Bypassed sensors are not capable of activating an alarm. Sensors will return to normal operation when the system is armed then disarmed. This prevents unintentional permanent disabling of a sensor. Central Station Channel A company to which alarm signals are sent during an alarm report. Also known as Central Monitoring Station (CMS). A channel is a communication path for events to be sent from the system to a selected destination. Channels can be set to UltraSync or Email. A channel has an associated event list which contains the events it is allowed to forward on. Channel Group Chime Group ...C... 204 P/N 466-5261 • REV D ISS 17NOV17 A channel group is one or more destinations for event messages to be sent to. When a message is sent to a channel group, it is sent to all the channels that it contains. It forms the basis of multi-path reporting in the system. All the sensors that will activate chime, when in chime mode. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Chime Mode An operational mode that will emit a ding-dong sound at the keypad when specific sensors are activated. A sensor in a normal state is “closed”. The security system monitors each sensor for changes in state from closed to open and can respond with certain actions such as sounding the siren. Closed For example, a reed switch on a front door may change from a closed state to an open state when the door opens. The communicator is responsible for notifying a control room or third party that an alarm event has occurred so an appropriate response can be made. Communicator It sends event messages to the specified destination including details such as where the event originated from and the type of event. The receiver will then log the time and date when it receives the event. For example, Alarm from Sensor 2 in Area 1 at 3:00am on 5/5/2014 from Account 1234. The system has multiple communicator options including Ethernet IP interface, email, and 3G (with optional cellular radio module). CPU Disarm Duress Code Entry Delay The main controller for the security system. It stores all programming, provides network and other connectivity options for reporting, and provides physical terminals for connecting power, backup battery, sensors, and outputs. To turn your security system Off. A predetermined user PIN code that will arm / disarm the security system while sending a special code to the central monitoring station indicating the user is entering / leaving the premises under duress. Only applicable on monitored systems. The time allowed to disarm your security system after the first detection device has been activated. Event Events are messages that are sent by the system due to system or area conditions. These include areas in alarm, opening and closing, sensor bypass, low battery, tamper, communication trouble, and power issues. Event List Event lists contain events that a channel is allowed to send to the specified destination. If a channel receives an event that is not in the associated event list, then the channel will ignore the event. Exit Delay Forced Arming Handover Master Code Menus The time allowed to exit the premises after the security system is armed. An option that permits arming even when there are open pre-selected sensors. Generally assigned to sensors that cover the system (e.g.; motion sensors, front door reed switches), allowing the user to arm the security system without the need to wait for those sensors to be closed. A security system that is ready to be “force armed” will flash the ready light. An instant alarm type, unless an entry sensor is tripped first. A PIN code that is used by a user to arm or disarm the security system. Its main feature is the ability to create, alter and delete user PIN codes. Can also be used as a function code for all features. The system has a large range of features sorted into various menus such as Users, System, and Sensors. Each menu item can be seen when using the UltraSync Web Server or the UltraSync app. Menus are used to restrict what is displayed by a device and what features a user has access to. Monitored ...C... 205 P/N 466-5261 • REV D ISS 17NOV17 A security system that is configured to send all alarm signals to a central monitoring station. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Open A sensor in an abnormal state is “open”. The security system monitors each sensor for changes in state from closed to open and can respond with certain actions such as sounding the siren. For example, when a PIR sensor detects movement it will change from a closed state to an open state Output Perimeter Permission Profile Outputs on the system can be connected to a siren and strobe when an alarm condition occurs on the system. Typically this refers to sensors located around the boundary of the protected area such as sensors on doors and windows, and excludes interior motion sensors. Permission includes a list of features a user or device is allowed to access. This includes programming menus, areas, reporting channels, actions, reporting options, access control options, special options, and special timers. Each user can have up to four (4) permission profiles. Each profile contains a set of permissions and a corresponding schedule. This allows advanced user programming and provides specific access to different features of the security system during specific dates/time. With advanced programming, profiles can be enabled/disabled in response to system conditions. Quick Arm Scene An option that allows you to turn on (arm) the security system by pressing the [AWAY] key. Each scene can trigger up to 16 actions to create an automation event. This can save users time by automatically running multiple actions. A scene can be triggered manually, through a schedule, or via a system event. A schedule is a list of up to 16 sets of days and times. Typically these are used to provide access to users only within the specified sets of days and times. Outside of the schedule a user will not have access to the system. Schedule Schedules are used to automatically arm and disarm specified areas using the Arm-Disarm feature. Scenes can perform a set of actions according to a specified schedule. Schedules themselves can be enabled and disabled through actions. This powerful feature allows you to provide conditional access to various users and devices based on system conditions. Sensor A detection device such as a Passive Infrared motion sensor (PIR), reed switch, smoke detector, panic button, etc. Sensors may be physically wired to the system. Also known as an input or sensor on other security panels. ...C... 206 Service Provider The installation / maintenance company servicing your security system. Stay Mode To turn your security system on when you are staying in the premises, this will automatically bypass pre-programmed sensors and arm others. Often used to arm only the perimeter while allowing movement inside the premises. P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Tamper A physical switch on a device that detects unauthorised access to the unit. For example opening the case of a sensor or taking a keypad off the wall can trigger a tamper alarm. This can provide early warning of someone attempting to undermine the security of your system. Some devices use an optical sensor to detect removal from a surface. Token UltraSync Each token is a pre-recorded word or phrase that can be used to name sensors, areas, outputs, and rooms. Mobile app for smartphones to access the UltraSync Web Server which provides access to view the status of a system, control sensors and outputs, program users and other features. Available to TM TM TM TM download for Apple iPhone and Google Android from the respective app store. The UltraSync app connects to the UltraSync server which will then connect to your system. UltraSync Web Server The system has a built-in web server which provides access to features via a web browser interface or a native smartphone app. This allows you to performing programming and control of the system without needing to be physically in front of the keypad. An authorised person who can interact with the system security system and perform various tasks according to the permissions assigned to them. Each user has a set of profile levels. These control what the user has access to, a list of functions, and when the user is allowed to perform these functions. User A user is typically a person who is assigned a PIN code and arms/disarms the system with this code or keyfob device. Users can also be automatic functions of the system. For example, the system can automatically arm specific areas a user has access to at a specified time. No human interaction is required; all the permissions of the programmed user will still be applied and enforced. User Code ...C... 207 P/N 466-5261 • REV D ISS 17NOV17 A PIN code that is used by a user to arm or disarm the security system. Also can be used as a function code for certain features. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub REFERENCE GUIDE A Appendices A.1 DLX 900 Software DLX 900 is a fully featured management tool for control rooms and security professionals. Compatible with Microsoft Windows 7 and 8, this is available to download from www.interlogix.com. In order for DLX 900 to connect to an UltraSync system you will need: The IP address of the system (or use the Discover feature for LAN connections) To know the Download Access Code (see Troubleshooting section, A.2) and, If Always Allow DLX 900 is enabled then you will be allowed to connect; if Always Allow DLX 900 is disabled then you must first put the UltraSync into program mode, this can be changed in Settings-Network. 1. Install and launch DLX 900 software. 2. Create a new customer and select the Panel. ...C... 208 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 3. Enter the TCP/IP address of the system, press Save. 4. Go to Communicator – Remote Access. 5. Enter the Download Access Code to match the one configured on the system. 6. Press the Connect TCP/IP button. To enable remote access for DLX 900 in UltraSync, change the Download Access Code. The default Download Access Passcode of 00000000 prevents remote access. Login to UltraSync Web Server and go to Settings – Network then change the code. Note: DLX 900 will attempt to connect using the default installer / 9–7–1–3 account. To disable DLX 900 access, change the Installer PIN code and set the Download Access Code to 00000000. ...C... 209 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.2 Troubleshooting DLX 900 Problem Solution Check you can ping the system. Check the Download Access Code. Check that remote access is enabled on the system. Cannot connect over TCP/IP You generally need to be on the same network to connect via TCP/IP. If you are connecting from a separate network, you will need to set up port forwarding to port 41796 on the router the system is connected to. Consult your router manual or your IT department for assistance. Technical support is unable to assist with setting up port forwarding due to differences in customer networks and equipment. Login to UltraSync Web Server and go to Settings – Network. Generally this will need to be done on-site with an internet browser. Do not know Download Access Code At factory default, DLX 900 will automatically allow a connection using the default Go To Program Code / Installer Code of 9–7–1–3 even if the Download Access Code is unknown or set to default of 00000000 (disable upload/download). This is a convenience feature for Installers and control rooms when a system is first installed. This is why you must change the Installer Code to protect the system from further changes. Once the Installer Code has been changed, this feature no longer works and you must have the correct Download Access Code. ...C... 210 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.3 Firmware Upgrade using DLX 900 Upgrading firmware can be performed remotely using DLX 900. 1. Check with your supplier to download the latest firmware file for your device. 2. Open DLX 900 and go to Devices – Device Info: 3. Select the device you want to upgrade. If you wish to update the system, select the Control Info tab. 4. Press Update Device, Update All of Type, or Update Control. 5. Select the firmware file. 6. Press OK. 7. Wait for the firmware files to transfer to your device(s). ...C... 211 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.4 Voice Library These words can be used to customize your sensor names. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 ...C... 212 zero one two three four five six seven eight nine ten eleven twelve thirteen fourteen fifteen sixteen seventeen eighteen nineteen twenty thirty forty fifty sixty seventy eighty ninety hundred thousand air conditioner area attic automatic auxiliary back basement bathroom bedroom 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 P/N 466-5261 • REV D ISS 17NOV17 boat cabinet car park ceiling cellar child’s alert closet computer cool curtain data den detector dining door downstairs driveway duress east emergency entry family fan fence fire forced arm foyer freezer front games garage gas gate glass glass break ground guest gun 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 gym hall hallway heat heating hold-up home home theatre infra-red inside instant interior key switch Keychain kitchen lounge laundry lift light living location master medicine meeting motion night north nursery office output outside panic pantry partial perimeter pool rear reception remote UltraSync Modular Hub Reference Manual 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 roof room rumpus safe security sensor shed shock shop side skylight sliding small smoke south stairs storage study temperature spare toilet training TV upstairs user utility volt veranda wall warehouse water west window windows wireless yard ©2016 United Technologies Corporation .. I ... .. . .. A.5 System Status Messages Various messages may appear on the Status screen of UltraSync Web Server and UltraSync app. System AC power fail – The security system has lost its electricity power. Low battery – The security system’s back up battery requires charging. Battery test fail – The security system’s back up battery requires changing. Box tamper – The security system’s cabinet tamper input has activated. Siren trouble – The security system’s external siren has a problem. Over current – The security system is drawing too much current. Time and date loss – The security system time and date need resetting. Communication fault – The security system has detected a problem with the communication channel Fire alarm – A fire alarm has been activated from the system Panic – A manual alarm has been activated from the system Auxiliary – A manual auxiliary alarm has been activated from the system Area Number / Area Name Is On in the away mode – This area is armed in the away mode. Is On in the stay mode – This area is armed in the stay mode. Is ready – This area is secure and ready to be armed. Is not ready – This area is NOT ready to be armed, a sensor is not secure. All areas are on in the away mode – All areas in this multi area system are armed in the away mode. All areas are on in the stay mode – All areas in this multi area system are armed in the stay mode. All areas are ready – All areas in this multi area system are secure and ready to be armed. Sensor Number / Sensor Name In Alarm – This sensor has triggered a system alarm condition. Is bypassed – This sensor is isolated (disabled) and will not activate an alarm. Chime is set – This sensor is part of the chime group. Is not secure – This sensor is not closed. Fire alarm – This sensor has triggered a fire alarm. Tamper – This sensor has triggered a tamper alarm. Trouble fault – This sensor has an open circuit. Loss of wireless supervision – This sensor is a wireless device and has lost its communication link with the control panel. Low battery – This sensor is a wireless device and needs its battery changed. ...C... 213 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.6 App and Web Error Messages Various error messages may appear on the UltraSync Web Server and UltraSync app. Advanced / Settings Configuration Menus "You must select a Menu before you can scroll" – An attempt was made to scroll up or down from the top level menu. "Select a submenu from the list or select back to access the main menu" – An attempt was made to scroll up or down from a submenu that has no additional levels. "Defaulting requires 2 levels" – a Shortcut was entered without two levels. Read Write errors and results "Write Access Denied" "Nothing displayed can be Saved" "Program Success!" "Name Saved" Sensors Page "No Sensors Configured For Your Access" – Displayed on Sensors page when there are no sensors available to view. Data Entry Errors "Data must only contain the following characters" "Date must be of the form YYYY–MM–DD." "Day must be from 1 to 31" "Data entry must only contain the numbers 0 – 9 and A–F" "Data entry must only contain the numbers 0 – 9" "Data must be a number from X to Y" "Improper Time Value" "must be 4 to 8 digits "You must enter a user Number between 1 and 1048575" "PIN digits must be between 0 and 9" "PIN Must be 4–8 digits from 0–9" "Data must not contain the following characters []" ...C... 214 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.7 Z-Wave Messages Z-Wave Messages ...C... 215 "Unavailable – Failed Device Function in progress" – An Attempt was made to enter an add remove mode when failed device mode is active. "Unavailable – Add mode active" – Attempt was made to enter an add remove mode when add mode is active. "Unavailable – Remove mode active" – An Attempt was made to enter an add remove mode when remove mode is active. "Unavailable – Resetting Network" – An Attempt was made to enter an add remove mode when resetting mode is active. "Unavailable – Backing Up Network" – An Attempt was made to enter an add remove mode when backup mode is active. "Unavailable – Restoring Network" – An Attempt was made to enter an add remove mode when restore mode is active. "Busy, Try Again Momentarily" – This message is received when the Z-Wave module is attempting a command and a new command was submitted. "Not primary controller" – An attempt was made to perform device functions when not a primary controller. "Device Not Found in failed list" – An attempt was made to remove a failed device that is now responding. "Remove Device failed – already in process" – An Attempt was made to enter remove mode when remove mode is active. "Replace Device failed – already in process" – An Attempt was made to enter Replace mode when Replace mode is active. "Remove Failed" – An Attempt to remove a device from the network has failed "Replace Failed" – An Attempt to replace a device from the network has failed "Function timed out or canceled" Add/Remove/Replace function timed out. "Unavailable, Try Again Later" – This message is received when the Z-Wave module is still initializing "Command Failed" – A Z-Wave command has failed. "You must press Select to choose a set point" – A set point change was attempted without selecting a set point to change. "There are no Failed Devices" – Displayed in the failed device dialog when no failed devices detected. P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.8 History Events The table below lists events that can appear in the event log. Event ID Table Event Name 24 Hour Alarm 24 Hour Alarm Restore Abort Activity Monitor fail Alarm Aborted Automatic Test Battery Low Event Battery Low Event Restore Box Tamper Box Tamper Restore Burg Alarm Burg Alarm Restore Bypass Bypass Restore Cancel Checksum Fault Checksum Fault Restore Clock Changed Close Communication Failure Communication Failure Restore Cross Zone initial trip Cross Zone initial trip Restore Device Enrolled Device Failure Device Failure Restore Door Access Door Access Denied Door Forced Door Forced Door Propped Door Propped Duress Early Opening Early Opening End Listen In End Local Program End Remote Program End Walk Test Mode End Sensor Test Exit Error Expander DC Loss Expander DC Loss Restore Expander Low Battery Expander Low Battery Restore Fail To Close Fail to Open Fire Alarm Fire Alarm Restore Fire Maintenance Alarm Fire Maintenance Alarm Restore ...C... 216 P/N 466-5261 • REV D ISS 17NOV17 Description Alarm was aborted UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Fire Supervision Fire Supervision Restore First Open Ground Fault Ground Fault Restore Guard Tour Fail Keypad Lockout Last Close Late Closing Late Opening Mains Fail Event Mains Fail Event Restore Man Down Manual Audible Panic Manual Fire Manual Auxiliary Manual Silent Panic Manual Test Manual Test Restore Open Output Activated Output Deactivated Over Current Over Current Restore Partial Close Partial Open Power Up Power Up Restore Recent Close Remote Program Fail Reserved Reserved Sensor Event Types/Restores Sensor Low Battery Sensor Low Battery Restore Serial Bus Expansion Event Siren Tamper Siren Tamper Restore Start Listen In Start Local Program Start Remote Program Start Walk Test Mode Start Sensor Test System Device Bypassed System Device Un-bypassed System Shut Down System Armed Tamper Tamper Restore Technician Arrival Technician Left Telephone Fault Telephone Fault Restore Trouble Trouble Restore User Activated Output Valid Code Entered Valid Code expired Valid Code lost Valid Code out of Schedule Valid Code Void ...C... 217 P/N 466-5261 • REV D ISS 17NOV17 Opening from Partial Arm Restore from system shutdown UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Walk Test Fail Walk Test Pass Watchdog Reset Wireless Jam Wireless Jam Restore Wireless Supervision Wireless Supervision Restore Sensor Activity Supervision Sensor Activity Supervision Restore A.9 Event Reporting Class Table Class Name Bypass/Bypass Restore Cancel Communication Failures Don’t care Fire Alarm Fire Restore Log Only Non-Fire Alarm Non-Fire Restore Open/Close Power Trouble Program Mode Recent Close/Abort Reserved Sensor Trouble/restore System trouble/Restore Tampers/Tamper Restore Test Reports Sensor Trouble/Restore ...C... 218 P/N 466-5261 • REV D ISS 17NOV17 Description Sensor has been isolated Used for devices that do not classify events. A fire device created an alarm A fire device restored from Alarm A non-fire device created an alarm. This includes auxiliary, panic, and burg. A non-fire device restored from alarm. An area turn on turn off Mains and battery trouble Local or remote programming Low battery or wireless supervision A system trouble event or restore. A tamper alarm or tamper restore. Manual or automatic test event A fire sensor or day sensor is in trouble or restored from trouble. UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.10 Action Events: Category and Types Action Events Category Sensor Events Area Events ...C... 219 Action Event Type Disabled Faulted Not Faulted Alarm Bypass Tamper Low Battery Trouble Supervision Chime Enabled Inhibited (Bypassed) Alarm Memory User Events Disabled Armed Away Armed Away + Bypass Armed Partial Auto Arm Warning Holdup Delay Timed Disarm Guard Tour Time Guard Tour Fail Man Down Timer Man Down Fail Entry Exit 1 or Exit 2 Exit 1 Exit 2 Silent Exit Active Exit Error Abort Window Cancel Window Sensor Cross Zone Timing Sensor Bypass Sensor Tamper Sensor Not Ready Sensor Low Battery Sensor Supervision Fault Chime On (from sensor) Walk Test (from sensor) Trouble (from sensor) Any Alarm Burg Alarm Fire Alarm Panic Alarm Auxiliary Alarm Any Siren Fire Siren Non-fire Siren Keypad Sounder DLX 900 Turn off command DLX 900 Turn on partial DLX 900 Turn on away Manual Fire Manual Panic Manual Auxiliary User Arm Trigger User Disarm Trigger P/N 466-5261 • REV D ISS 17NOV17 Action Events Category Logic State Schedule States Device Status System Events Room Events UltraSync Modular Hub Reference Manual Action Event Type Disabled PIN entered PIN Entered out of schedule Void PIN Entered Lost PIN Entered Expired PIN Entered Turn On By User Turn Off By User Disabled Action State True Manual Output On Manual Output Off Scene Activated Action State False Disabled Schedule State Disabled Fire Alarm Verification Box Tamper Local Programming Remote Programming Battery Test Off line Power Up delay Shut Down Phone Communicator trouble Phone Line fault Ethernet Trouble Ethernet No Link Ethernet to Server Fault Cellular Radio Trouble Cellular Radio to Server Fault Event in Reporting Queue Smoke Power Fail Mains Fail Low System Battery Strobe On Siren On Siren Tamper Disabled Remote Program Fail Watchdog Reset Disabled Connected To Pending Connection To Privacy Talking Using Channel 1 Using Channel 2 ©2016 United Technologies Corporation .. I ... .. . .. A.11 Action Results Category and Action Results Event Types Action Results Category Sensor Results Action Results Event Type Sensor Trip Toggle Sensor Trip Sensor Restore Sensor Bypass Toggle Sensor Bypass Sensor Unbypass Sensor Chime Toggle Sensor Chime On Sensor Chime Off Action Results Category User Results System Results Area Results Scene Results ...C... 220 Arm Away Turn Off Silence Arm Stay Toggle Arm Stay Arm Away No Auto Stay Chime Toggle Chime On Chime Off Automatic Sensor Test Toggle Automatic Sensor Test On Automatic Sensor Test Off Auto Arm Timer Restart Disarm Timer Restart Man Down Timer Restart Guard Tour Timer Restart Hold Up Timer Restart Activity Timer Restart Arm or Disarm Test Timer Restart Device Results Camera Results Action Results Event Type User Expire or Activate User Activate User Deactivate Disabled Detector Reset Communicator Test Disabled Battery Test Start Siren Device Bypass Device Unbypass Camera 1 Camera 2 Camera 3 Camera 4 Camera 5 Camera 6 Camera 7 Camera 8 Camera 9 Camera 10 Camera 11 Camera 12 Camera 13 Camera 14 Camera 15 Camera 16 Scene 1 Scene 2 Scene 3 Scene 4 Scene 5 Scene 6 Scene 7 Scene 8 Scene 9 Scene 10 Scene 11 Scene 12 Scene 13 Scene 14 Scene 15 Scene 16 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.12 System Building Blocks On the following page is the system diagram of system showing all the different building blocks that can be used to create an UltraSync system. You have full flexibility to customise your system. Program each building block in turn to complete your system. We suggest left to right, top to bottom. Refine blocks as you go or use pre-sets to save you time. The smaller grey blocks indicate related blocks that are used by the larger blue block. The number on the bottom right of each block indicates the capacity of the system. ...C... 221 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. System Sensor Types a) System Clock b) System and Siren c) Timers d) Maintenance and Test Sensor Options Zones - Area Armed - Area Disarmed a) Profile 1 b) Profile 2 32 32 Sensor Type Sensor Options Area Group Schedule User up to 512* Communicator Areas a) General Options c) IP Config d) Ethernet d) Radio d) Dial IP d) Email e) Remote Access 128 f) System Event Reporting Area Groups a) Area Options b) Area Timers c) Area Reporting Schedule Channel Groups up to Areas 96* Channel Groups Event Lists Channels 16 Holidays Channel Groups Communicator Event Lists 16 Schedules Channels Menus 16 Permissions 4 96 Holidays 64 User a) Groups b) Options/Timers Menus Area Groups Channel Groups Action Groups a) Setup b) Security… c) History… d) Communications e) Times… a) Main b) Advanced 128 Permissions Schedules up tp 256* Arm/Disarm User Schedule Actions 96 Action Groups Scenes Devices Outputs zone expanders, keypads, transmitters up to Actions 256* 64 Speech Tokens ...C... 222 P/N 466-5261 • REV D ISS 17NOV17 Actions Schedules 16 Permissions Schedules 64 Network Servers UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.13 System Menu Tree The menu structure as seen from the Advanced menu in UltraSync Web Server: 910.1 910.2 1. 2. 3. 4. 5. 6. 7. 8. Users System System Clock General Options System Timers Siren Options Service and Test Options Status System Counters Language 1. Language 2. Voice language 9. Automation Menu 910.3 Sensors 1. Sensor Number 2. Sensor Name 3. First Sensor Profile 4. Second Sensor Profile 910.4 Areas 1. Area Number 2. Area Name 3. Area Entry-Exit Times 4. Area Options 5. Area Timers 6. Area Type Settings 7. Area Event Reporting 910.5 Reporting and Notifications 1. Channel Number 2. Channel Name 3. Account Number 4. Format 5. Device Number 6. Dest Phone or Email or Push 7. Next Channel 8. Event List 9. Attempts 10. Language 910.6 Communicator 1. General Options 2. Auto Test 3. IP Configuration 1. IP Host Name 2. IP Address 3. Gateway 4. Subnet 5. Primary DNS 6. Secondary DNS 7. Ports 8. Time Server 9. IP Options 4. Cellular Configuration 5. Remote Access 1. Panel Device Number 2. Download Access Code 3. Call Back Number 4. Callback Server 5. Number Of Rings 6. Number of Calls 7. Answering Machine Defeat 8. Download Options 6. System Event Reporting 1. System Channel 2. Attempts ...C... 223 P/N 466-5261 • REV D ISS 17NOV17 910.7 Schedules 1. Schedule Number 2. Schedule Name 3. Follow Action Number 4. Times and Days 910.8 Actions 1. Action Number 2. Action Name 3. Function 4. Duration Minutes 5. Duration Seconds 6. Event 1 7. Event 2 8. Event 3 9. Event 4 10. Result 910.9 Auto Arm-Disarm 1. Arm-Disarm Number 2. Name 3. User Number 4. Schedule Number 910.10 Devices 1. System Devices 1. Control 2. Keypad 3. Zone Expanders 4. Relay Expanders 5. Power Supplies 2. Interlogix Transmitters 1. Transmitter Number 2. Serial Number 3. User 4. Options 5. Scene 6. Signal Strength 3. Z-Wave Devices 1. Name 2. Basic Type 3. Generic Type 4. Specific Type 910.11 Permissions 1. Permission Number 2. Permission Name 3. Control Groups 4. Permission Options 5. User Timer Options 910.12 Area Groups 1. Area Group Number 2. Area Group Name 3. Area List 910.13 Menus 1. Menu Number 2. Menu Name 3. Menu Selections 910.14 Holidays 1. Holiday Number 2. Holiday Name 3. Date Range UltraSync Modular Hub Reference Manual 910.15 1. 2. 3. 4. 910.16 1. 2. 3. 4. 5. 6. 910.17 1. 2. 3. 910.18 1. 2. 3. 910.19 1. 2. 3. 910.20 1. 2. 3. 4. 5. 6. 910.21 1. 2. 3. 4. 5. 6. 7. 8. 9. 910.22 1. 2. 3. 4. 910.23 1. 2. 3. 4. 5. 6. 7. 8. 9. Sensor Types Sensor Type Number Sensor Type Name Sensor Type Armed Sensor Type Disarmed Sensor Options Sensor Options Number Sensor Options Name Sensor Options Sensor Reporting Sensor Contact Options Sensor Report Event Event Lists Event List Number Event List Name Event List Channel Groups Channel Group Number Channel Group Name Channel Action Groups Action Group Number Action Group Name Action Group List Scenes Scene Number Scene Name When Should Scene Work Scene Trigger Type Activate Sensor Scene Results Speech Tokens Sensor Number Voice Name 1 Voice Name 2 Voice Name 3 Voice Name 4 Voice Name 5 Voice Name 6 Voice Name 7 Voice Name 8 Cameras Camera Number Camera Name LAN IP Address MAC Address Network Servers Web Access Passcode Ethernet Server 1 Ethernet Server 2 Ethernet Server 3 Ethernet Server 4 Cellular Server 1 Cellular Server 2 Cellular Server 3 Cellular Server 4 ©2016 United Technologies Corporation .. I ... .. . .. A.14 Calculating Maximum Bus Cable Length When long RS-485 bus cable runs and/or many devices are connected on a single cable segment, voltage losses on the bus wiring may cause the bus voltage to drop below the required level to power the connected devices. Factors contributing to voltage drop: 1. The more devices that are connected on the cable segment, the higher the current and hence, the higher the voltage drop 2. The longer the cable run, the higher the voltage drop 3. A lower gauge wire will have more voltage drop than a higher gauge wire If these factors drop the bus voltage below the minimum voltage required to power the connected devices (device shutdown voltage), a UM-SPS Smart Power Supply must be inserted in the cable segment such that the bus voltage remains above the device shutdown voltage. When designing the power system, you must design it for the worst case scenario. That is, 1) when AC power is lost and the system is operating off of battery power and 2) for the alarm or maximum current of the connected devices. When AC power is lost and the system is operating off of battery power, the system will shut down when the CPU output voltage drops below 10 VDC. Thus, the voltage drop from 10 VDC must be used to determine the bus voltage given the total current on that section of bus wiring AND the gauge of the wiring used. 1. Add up the maximum current on the bus segment 2. Determine the highest shut down voltage for all devices on the bus segment 3. Use the appropriate chart below for the AWG of the cable for this segment to determine the maximum cable length 4. If the actual bus segment length exceeds the maximum cable length in the chart, you will need to break up the segment with a UM-SPS Smart Power Supply. ...C... 224 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Example calculation of total bus segment current: Total Bus segment current: 600mA Worst Case device shut-down voltage: 7.75 VDC (keypad) 22 AWG wire For example, if the bus length is 200 feet, the corresponding bus voltage will be 6 VDC which is less than the shutdown voltage of the UM-1820E Touch Screen Keypads (7.75 VDC). In this instance, a UM-SPS Smart Power Supply would need to be inserted in the bus at the 100’ location. ...C... 225 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Bus Voltage, 24 AWG Bus Wire Bus Length in Feet Bus Current mA 25 30 45 50 55 60 70 80 90 175 350 525 700 875 1000 50 100 200 500 750 1000 1500 2000 2500 9.9 9.9 9.9 9.9 9.9 9.8 9.8 9.8 9.8 9.5 9.1 8.6 8.2 9.9 9.8 9.8 9.7 9.7 9.7 9.6 9.6 9.5 9.1 8.2 7.3 6.3 9.7 9.7 9.5 9.5 9.4 9.4 9.3 9.2 9.1 8.2 6.3 4.5 2.7 9.3 9.2 8.8 8.7 8.6 8.4 8.2 7.9 7.6 5.4 0.8 0.0 0.0 9.0 8.8 8.2 8.0 7.8 7.6 7.3 6.9 6.5 3.1 0.0 0.0 0.0 8.7 8.4 7.6 7.4 7.1 6.9 6.3 5.8 5.3 0.8 0.0 0.0 0.0 8.0 7.6 6.5 6.1 5.7 5.3 4.5 3.7 2.9 0.0 0.0 0.0 0.0 7.4 6.9 5.3 4.8 4.2 3.7 2.7 1.6 0.6 0.0 0.0 0.0 0.0 6.7 6.1 4.1 3.5 2.8 2.1 0.8 0.0 0.0 0.0 0.0 0.0 0.0 7.7 7.4 5.4 4.8 0.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Bus Voltage, 22 AWG Bus Wire Bus Length in Feet Bus Current mA 25 30 45 60 100 175 250 350 400 525 600 700 875 1000 ...C... 226 50 100 200 500 750 1000 1500 2000 2500 10.0 10.0 9.9 9.9 9.8 9.7 9.6 9.4 9.3 9.1 9.0 8.8 8.6 8.4 9.9 9.9 9.9 9.8 9.7 9.4 9.2 8.8 8.7 8.3 8.0 7.7 7.1 6.7 9.8 9.8 9.7 9.6 9.3 8.8 8.4 7.7 7.4 6.5 6.0 5.4 4.2 3.4 9.6 9.5 9.3 9.0 8.4 7.1 5.9 4.2 3.4 1.4 0.1 0.0 0.0 0.0 9.4 9.3 8.9 8.5 7.5 5.7 3.8 1.4 0.1 0.0 0.0 0.0 0.0 0.0 9.2 9.0 8.5 8.0 6.7 4.2 1.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8.8 8.5 7.8 7.0 5.1 1.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8.4 8.0 7.0 6.0 3.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7.9 7.5 6.3 5.1 1.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Bus Voltage, 20 AWG Bus Wire Bus Length in Feet Bus Current mA 25 30 45 60 100 175 250 350 400 525 600 700 875 1000 50 100 200 500 750 1000 1500 2000 2500 10.0 10.0 10.0 9.9 9.9 9.8 9.7 9.6 9.6 9.5 9.4 9.3 9.1 9.0 9.9 9.9 9.9 9.9 9.8 9.6 9.5 9.3 9.2 8.9 8.8 8.5 8.2 7.9 9.9 9.9 9.8 9.8 9.6 9.3 9.0 8.5 8.3 7.8 7.5 7.1 6.4 5.9 9.7 9.7 9.5 9.4 9.0 8.2 7.4 6.4 5.9 4.6 3.8 2.7 0.9 0.0 9.6 9.5 9.3 9.1 8.4 7.3 6.1 4.6 3.8 1.8 0.7 0.0 0.0 0.0 9.5 9.4 9.1 8.8 7.9 6.4 4.8 2.7 1.7 0.0 0.0 0.0 0.0 0.0 9.2 9.1 8.6 8.1 6.9 4.6 2.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9.0 8.8 8.1 7.5 5.9 2.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8.7 8.4 7.7 6.9 4.8 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Bus Voltage, 18 AWG Bus Wire Bus Length in Feet Bus Current mA 25 30 45 60 100 175 250 350 400 525 600 700 875 1000 ...C... 227 50 100 200 500 750 1000 1500 2000 2500 10.0 10.0 10.0 10.0 9.9 9.9 9.8 9.8 9.7 9.7 9.6 9.5 9.4 9.3 10.0 10.0 9.9 9.9 9.9 9.8 9.7 9.5 9.5 9.3 9.2 9.1 8.9 8.7 9.9 9.9 9.9 9.8 9.7 9.5 9.3 9.1 9.0 8.6 8.4 8.2 7.7 7.4 9.8 9.8 9.7 9.6 9.3 8.9 8.4 7.7 7.4 6.6 6.1 5.4 4.3 3.5 9.8 9.7 9.6 9.4 9.0 8.3 7.6 6.6 6.1 4.9 4.1 3.2 1.4 0.2 9.7 9.6 9.4 9.2 8.7 7.7 6.7 5.4 4.8 3.2 2.2 0.9 0.0 0.0 9.5 9.4 9.1 8.8 8.0 6.6 5.1 3.2 2.2 0.0 0.0 0.0 0.0 0.0 9.3 9.2 8.8 8.4 7.4 5.4 3.5 0.9 0.0 0.0 0.0 0.0 0.0 0.0 9.2 9.0 8.5 8.0 6.7 4.3 1.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Bus Voltage, 16 AWG Bus Wire Bus Length in Feet Bus Current mA 25 30 45 60 100 175 250 350 400 525 600 700 875 1000 ...C... 228 50 100 200 500 750 1000 1500 2000 2500 10.0 10.0 10.0 10.0 10.0 9.9 9.9 9.9 9.8 9.8 9.8 9.7 9.6 9.6 10.0 10.0 10.0 10.0 9.9 9.9 9.8 9.7 9.7 9.6 9.5 9.4 9.3 9.2 10.0 10.0 9.9 9.9 9.8 9.7 9.6 9.4 9.3 9.1 9.0 8.9 8.6 8.4 9.9 9.9 9.8 9.8 9.6 9.3 9.0 8.6 8.4 7.9 7.5 7.1 6.4 5.9 9.8 9.8 9.7 9.6 9.4 8.9 8.5 7.9 7.5 6.8 6.3 5.7 4.6 3.9 9.8 9.8 9.6 9.5 9.2 8.6 8.0 7.1 6.7 5.7 5.1 4.3 2.9 1.8 9.7 9.6 9.4 9.3 8.8 7.9 6.9 5.7 5.1 3.6 2.6 1.4 0.0 0.0 9.6 9.5 9.3 9.0 8.4 7.1 5.9 4.3 3.5 1.4 0.2 0.0 0.0 0.0 9.5 9.4 9.1 8.8 8.0 6.4 4.9 2.9 1.8 0.0 0.0 0.0 0.0 0.0 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. A.15 Z-Wave Home Automation Hub When the optional UM-ZW Z-Wave Module is added, this system is a Z-Wave security enabled device allowing control of Z-Wave home automation devices. A secure Z-Wave controller is required to fully utilize the product. The UltraSync Modular Hub can act as a secure Z-Wave controller. Z-Wave compliant devices regardless of manufacturer can be used in the same network and always-on devices can function as repeaters to extend the range of Z-Wave devices. Supported 3rd party Z-Wave devices include selected light switches, dimmers, thermostats, and door locks. Door locks which support secure encryption can be used, unencrypted locks cannot be added to this system. This system may natively support setting and retrieving on/off states, setting and retrieving dimming levels, and locking/unlocking. Adding Z-Wave Devices 1. Log in to Web Server or UltraSync + app. Master access level is required for programming the Z-Wave devices into UltraSync Modular Hub. 2. Click Settings, Rooms and edit Room Names. 3. Click Settings, Z-Wave Add/Remove. 4. If a Z-Wave device has been added previously to another system, the Z-Wave standard requires it to be removed before adding it to a new system. To do this, click Remove, then activate LINK or REMOVE mode on the device. ...C... 229 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 5. Click Add. 6. Initiate LINK or ADD mode on Z-Wave device. See your Z-Wave device’s manual for instructions. 7. Click Rooms. 8. The device will appear in the list. Click a button such as ON or OFF to verify you can control the device. ...C... 230 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Programming a Z-Wave Siren Some Z-Wave sirens identify themselves as a true siren, while others identify themselves as binary on/off switches. There are different programming steps for each. If you have added a Z-Wave siren that identifies as a binary on/off type, you can program it to activate when the system siren activates: 1. Log in to Web Server or UltraSync + app. 2. Click Advanced\ Devices\ Zwave Devices\. 3. Select the Z-Wave siren in the drop down list. 4. Click Zwave Options. 5. Enable 'Siren Mode'. 6. Click Save. 7. Arm your system and trip a sensor to cause the system siren to activate. Verify your ZWave siren also activates. 8. Disarm your system. Some Z-wave sirens can follow each keypad beep during Exit Delay and Entry Delay. This is enabled under: 1. Log in to UltraSync Modular Hub Web Server or UltraSync + app. 2. Click Advanced\ System\ Siren Options\. 3. Enable ' Z-Wave Siren Chirps Entry and Exit'. 4. Click Save. When this option is off, only the system siren should sound during Entry and Exit Delay. Note: Some Z-wave sirens have a built-in timer and ignore advanced features. They will continue to sound for the duration of their internal timer. ...C... 231 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Removing Z-Wave Devices 1. Log in to Web Server or UltraSync + app. 2. Click Settings, Z-Wave Add/Remove. 3. Click Remove. 4. Press the include button on the Z-Wave device you want to remove. See your Z-Wave device’s manual for instructions. 5. Device will be removed. ...C... 232 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Adding UltraSync Modular Hub to existing Z-Wave network as Secondary Controller 1. 2. 3. 4. Log in to Web Server or UltraSync + app. Click Settings, Z-Wave Add/Remove. Start the Add process on the primary controller of the existing network. Press the Include button on the screen of the UltraSync Modular Hub (the secondary device): 5. Primary Controller will add the UltraSync Modular Hub to it. 6. Status on screen will update to indicate it has been added as Secondary Controller. 7. Save settings on Primary Controller. ...C... 233 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Removing UltraSync Modular Hub from existing Z-Wave network as Secondary Controller 1. 2. 3. 4. Log in to Web Server or UltraSync + app. Click Settings, Z-Wave Add/Remove. Start the Remove process on the primary controller of the existing network. Press the Exclude button on the UltraSync Modular Hub (the secondary device): 5. Primary Controller will remove UltraSync Modular Hub from it. 6. UltraSync Modular Hub status will update. 7. Save settings on Primary Controller. ...C... 234 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Adding UltraSync Modular Hub to existing Z-Wave network as Primary Controller 1. Log in to Web Server or UltraSync + app. 2. Click Settings, Z-Wave Add/Remove. 3. Start the Control Shift function on the primary controller of the existing network. This will typically involve pressing a “Shift” button. 4. Press the Include button on the UltraSync Modular Hub (the secondary device): 5. UltraSync Modular Hub now displays “Alarm is Primary Controller” to indicate successful shift: 6. UltraSync Modular Hub will now be the Primary Z-Wave Controller, and the other network is the Secondary Z-Wave Controller. ...C... 235 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Relinquish Primary Control of UltraSync Modular Hub to another Controller 1. Log in to Web Server or UltraSync + app. 2. Click Settings, Z-Wave Add/Remove. 3. Check UltraSync Modular Hub is the primary controller and a secondary controller is already learnt in to UltraSync Modular Hub. UltraSync Modular Hub in Primary Controller mode will display Add Remove Cancel Shift and Include buttons: 4. Press the Shift button on UltraSync Modular Hub (the Primary Controller). 5. Press the Exclude button on the Secondary Controller. 6. UltraSync Modular Hub Primary Controller relinquishes control and becomes Secondary Controller. Only the Exclude button is visible indicating the UltraSync Modular Hub is Secondary Controller: ...C... 236 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 7. Secondary Controller shifts into Primary Controller. Replacing a Failed Node 1. 2. 3. 4. Click Settings – Zwave Maintenance On the Failed Device Selector, click the node to be replaced. Click the Replace button. Press the include button on the new node. ...C... 237 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Removing a Failed Node 1. 2. 3. 4. Click Settings – Zwave Maintenance On the Failed Device Selector, click the node to be removed. Click the Remove button. Status will show “Device Removed” when successful. Send User PINs to Z-Wave Door Lock UltraSync Modular Hub can send user PIN codes to an existing Z-Wave Door Lock so the PIN codes on the alarm system can also be used to operate the door lock. This feature is available to User Types – Engineer, Master, and Custom users with Z-Wave menu access. Communication is one way from the UltraSync Modular Hub to the lock, instructing the lock to add or remove PIN codes. Each lock is individually controlled. When “Send PIN(s) to Lock” is selected, UltraSync Modular Hub queries the lock for the number of standard users it supports. Some locks support up to 250 PINS, others are limited to 40. Check your lock documentation. Each UltraSync Modular Hub user number is sent to the same numbered slot in the lock, up to the maximum slots available in the lock. For example, UltraSync Modular Hub user number 1 will be sent to the Z-Wave Door Lock slot 1. Users exceeding the capacity of the lock will not be sent. Existing PIN codes in the door lock will be over-written. If the lock detects a duplicate PIN then the send command will fail. Selecting “Remove PIN(s) from Lock” will clear all PIN codes from the lock, whether or not they were added by the UltraSync Modular Hub. Some door locks have special master/installer PIN codes, these will not be changed. However, if they are default standard user PIN codes then UltraSync Modular Hub will have access to change or remove them. Each lock is different and you should test this feature on your specific lock to ensure only the appropriate codes are present. ...C... 238 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. 1. 2. 3. 4. 5. 6. Log in to UltraSync Modular Hub Web Server or UltraSync + app. Click Settings – Lock PIN Share. Select the Z-Wave Door Lock in the drop down list. Wait for the “Building User List- Please Wait” message to be replaced with “Ready”. The default will have “All Users” pre-selected. You may select an individual user instead. Optional and recommended, click “Remove PIN(s) from Lock”. This ensures any extra PIN codes are removed from the lock and only the PIN codes from UltraSync Modular Hub can operate the lock. Once completed it will show “Removed All Users”. 7. Click “Send PIN(s) to Lock. 8. PIN codes will be sent to Z-Wave door lock one at a time. Once completed it will show “Sent All Users”. 9. Test PIN codes on door lock and verify only the desired codes can operate the lock. 10. Refer to door lock manual to remove or change installer / master codes from door lock. As PIN codes can also be changed on the door lock, over time there may be a mismatch in PINs on the door lock compared to UltraSync Modular Hub. To avoid this confusion, only make PIN code changes via UltraSync Modular Hub. ...C... 239 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync + app and Web Server Error Messages Various error messages may appear on the UltraSync Modular Hub Web Server and the UltraSync + application. These apply when the optional UM-ZW Z-wave Module module is installed/ • • • • • • • • • • • • • • • • • • ...C... 240 "Unavailable - Failed Device Function in progress" - An attempt was made to enter an add/ remove mode when the failed device mode is active. "Unavailable - Add mode active" - An attempt was made to enter an add/remove mode when the add mode is active. "Unavailable - Remove mode active" - An attempt was made to enter an add/remove mode when the remove mode is active. "Unavailable - Resetting Network" - An attempt was made to enter an add/remove mode when the resetting mode is active. "Unavailable - Backing Up Network" - An attempt was made to enter an add/remove mode when the backup mode is active. "Unavailable - Restoring Network" - An attempt was made to enter an add/remove mode when the restore mode is active. "Busy, Try Again Momentarily" - This message is received when the Z-Wave module is attempting to execute a command and a new command was submitted. "Not primary controller" - An attempt was made to perform device functions when not a primary controller. "Device Not found in failed list" - An attempt was made to remove a failed device that is now responding. "Remove Device failed - already in process" - An attempt was made to enter a remove mode when the remove mode is active. "Replace Device failed - already in process" - An attempt was made to enter a replace mode when the replace mode is active. "Remove Failed" - An attempt to remove a device from the network has failed. "Replace Failed"- An attempt to replace a device from the network has failed. "Function timed out or cancelled" Add/Remove/Replace function timed out. "Unavailable, Try Again Later" - This message is received when the Z-Wave module is still initializing. "Command Failed" - A Z-Wave command has failed. "You must press Select to choose a set point" - A set point change was attempted without selecting a set point to change. "There are no Failed Devices" - Displayed in the failed device dialog when no failed devices detected. P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Specifications S.1 CPU Power Input Specifications AC input: DC input: 16 - 18 VAC 18 - 26 VDC Auxiliary power output (POS/NEG) 13.8 VDC +/- 0.2 V, 1 A max. Fused, self-resetting Battery type Maximum Battery Capacity Battery low condition Lead acid rechargeable 12 AH From 10.0 VDC to 11.0 VDC (If voltage falls below 11 VDC a system event is generated) Battery disconnect voltage 10.0 VDC (system shutdown) S.2 System General Features Code combinations End-of-line resistor Onboard zones From 10,000 (4 digits) to 100,000,000 (8 digits) 820 Ω 2 wire smoke 3.3 kΩ (default) 3.74 kΩ and 6.98 kΩ zone double EOL 8 (default); 16 if zone doubling enabled Maximum sensor number: UM-5000 500 Additional inputs Onboard outputs Maximum relays Maximum actions 2 – box tamper 5 limited by bus capacity 256, main panel supports 32 actions, each relay expansion module adds 32 actions, 7 relay expansion modules will provide a maximum of 256 actions Areas Keypads Expansion Modules/Bus Devices Users User Permissions 96 64 64 (including keypads) 256 128 Non-volatile Memory System event log capacity Video event log capacity 1024 1024 Ethernet connection Supported standard Speed Duplex Cabling IEEE 802.3u 10BASE-T or 100BASE-TX Half-duplex and full-duplex FTP (foiled twisted pair) Cat 5e cable or better ...C... 241 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UltraSync Modular Hub bus Type Range Recommended Cable 4 wire RS485 Bus High common mode tolerance (25V) 2,600 ft. (800m) 2 pair twisted, 22 AWG data cable Hardwired Zones Wiring Resistance 200Ω maximum S.3 Current Consumption* Device UM-5000-CPU CPU output UM-1820E Keypad UM-R4 4-Relay Module*** UM-R10 10-Relay Module*** UM-Z8 8-Zone Module UM-Z20 20-Zone Module UM-W7 Wireless Module*** UM-C-H1 Cellular Module UM-ZW Z-Wave Module Voltage Minimum (device shutdown) Average* Alarm** (Maximum) 10 100 100 7.75 90 175 6.55 25 125 25mA if no relays are energized. 6.55 25 160 25 mA if no relays are energized. 6.55 35 35 6.55 45 45 7.75 40 65 NA 30 100 - - - Output 1 NA 0 Output 2 Output 3 Output 4 Output 5 NA NA NA NA 0 0 0 0 490 4 ohm 230 8 ohm 140 ma 16 ohm 0 0 0 0 Comments Battery voltage level for CPU shutdown. Does not include powered sensor current Does not include powered sensor current 40 mA relay off 65 mA relay energized Typical values for speaker operation. Consult DC Siren specifications for value Connection dependent Connection dependent Connection dependent Connection dependent * Use for battery backup calculation ** Use for power supply calculation and 5 minute battery backup calculation *** Max current value is assuming all relays on the module are energized. If relays are inactive, calculation can be de-rated 25 mA per inactive relay. If positive switching is utilized, additional current draw of connected load must be included in power budget calculations. Consult current product documentation for the most up-to-date consumption rates ...C... 242 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. S.4 Battery Capacity Calculations When performing battery backup calculations, determine the entire system average and maximum current draw per the table above. . If you are powering hardwired zones from the CPU or zone expansion modules, remember to include the current draw from the sensors in your current calculation. Sample Current Budget Average Current (mA) 550 Alarm/Maximum Current (mA) 950 With these system current values calculated, determine the required battery capacity, in Amp Hours (AH), to provide the required backup time. Below are sample battery backup calculations. 24 hr. Battery Backup Calculation Formula 24 hour non-Alarm Amp Hour Calculation 5 minute Alarm Amp Hour Calculation Total Battery Requirements in Amp Hours 550*24/1000 950*5/60/1000 4 hr. Battery Backup Calculation Formula 4 hour non-Alarm Amp Hour Calculation 5 minute Alarm Amp Hour Calculation Total Battery Requirements in Amp Hours 550*4/1000 950*5/60/1000 Amp Hours 13.20 0.08 13.28 Amp Hours 2.20 0.08 2.28 Battery Options Part Number Capacity 60-681 4 Amp Hours 60-680 7 Amp Hours 60-781 17.2 Amp Hours In this example, a 17 Amp Hour battery would be required for 24 hour backup and a 4 Amp Hour battery would be required for 4 hour backup. ...C... 243 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. S.5 Environmental Operating temperature Humidity +14°F to +131°F (-10 to +55°C) 95% non-condensing S.6 Physical Dimensions Product Main description Dimensions (LxWxH) UM-5000 500 Zone CPU w/ IP & PSTN 4.64” x 5.55” x 2.0” (118 x 141 x 51mm) UM-PE Plastic Enclosure 13.3” x 13.3” x 3.7” (338 x 338 x 94mm) UM-CME Metal Enclosure 18.58” x 15.55” x 4.33” (472 x 395 x 110mm) UM-1820E Touchscreen keypad .70” x 3.27” x 4.92” (18 x 82 x 125mm) UM-Z8 8 zone expansion module 4.64” x 2.79” x 2.0” (118 x 71 x 51mm) UM-Z20 20 zone expansion module 4.64” x 2.79” x 2.52” (118 x 71 x 64mm) UM-R4 4 relay expansion module 4.64” x2.79” x 2.0” (118 x 71 x 51mm) UM-R10 10 relay expansion module 4.64” x 2.79” x 2.52” (118 x 71 x 64mm) S.7 Fuses Battery 12 V aux System LAN 4 A, self-resetting 2 A, self-resetting 2 A, self-resetting Output, high current output J10 POS Siren, high current output J7 OP1+ Strobe, high current output J7 OP2+ | | 2A combined | S.8 Maintenance No regular maintenance needed. System will report servicing when necessary. S.9 System Monitoring The system provides monitoring for the following items. Monitoring function Message Cause AC Mains Mains fail Loss of external power supply [1] Battery Battery low Battery low voltage [1] Battery test fail Fuse/power output fail ...C... 244 P/N 466-5261 • REV D ISS 17NOV17 Exhausted battery Battery charger fail Output overload UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Monitoring function Message Cause Power outputs Fuse/power output fail Exhausted fuse Fuse loss Short circuit Overload Power supply Power unit/power output fail Power unit failure Overvoltage Tampers Device tamper Device sabotage S.10 SIA and CID Reporting Code Descriptions # SIA code CID code Function Reporting priority Note 1. AN R393 Detector dirty restore Low 2. AR R301 AC restore Low 3. AS E393 Detector dirty Low 4. AT E301 AC trouble Medium 5. BA E130 Burglary alarm Alarm / input in mask / trouble when set Medium 6. BB E570 Burglary bypass Alarm inhibit Low 7. BC E406 Burglary cancel Cancel alarm by user / key / remotely Low 8. BJ R381 Detector supervision restore Low 9. BR R130 Burglary restore Low 10. BT E380 Burglary trouble Input in mask / trouble when unset Low 11. BU R570 Burglary unbypass Alarm uninhibit Low 12. BV E139 Alarm confirm ACPO Medium 13. BW R139 Restore confirmed alarm ACPO Low 14. BZ E381 Detector supervision 15. CF E408 Forced closing Set by user / by key Low 16. CG E456 Part set Part set by user / by key / remotely Low 17. CL R401 Closing normal Set by user Low R407 Closing normal Set remotely Low R409 Closing normal Set by key Low Low 18. EE E374 Exit error Exit fault Medium 19. ER R143 Expansion restore Expander / keypad trouble restore Low R300 Expansion restore Expander fuse restore Low R330 Expansion restore Expander / keypad communication restore Low E143 Expansion trouble Expander / keypad trouble Low E300 Expansion trouble Expander fuse failure Low E330 Expansion trouble Expander / keypad communication fault Low E110 Fire alarm 20. 21. ET FA ...C... 245 P/N 466-5261 • REV D ISS 17NOV17 High UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. # SIA code CID code Function Note Fire inhibit Reporting priority 22. FB E570 Fire bypass 23. FJ R373 Fire trouble restore Low 24. FR R110 Fire restore Low 25. FT E373 Fire trouble Low 26. FU R570 Fire unbypass 27. FW – Fire long supervision 28. HA E121 Holdup alarm Duress High 29. HR R121 Holdup restore Duress restore Low 30. JP E466 Service in Low 31. JR R466 Service out Low 32. JT E625 Time changed Low 33. LB E627 Local programming begin Low 34. LR R351 Line restore Low 35. LS R628 Local programming stop Low 36. LT E351 Line fault Low 37. MA E100 Medical alarm High 38. MB E570 Medical bypass Low 39. MJ – Medical long supervision restore Low 40. MR R100 Medical restore Low 41. MS – Medical long supervision Low 42. MU R570 Medical unbypass Low 43. OP E401 Unset normal Unset by user Low E407 Unset normal Unset remotely Low E409 Unset normal Unset by key Low Unset by user / key / remotely Low Fire uninhibit Low Low Low 44. OR E406 Unset from alarm 45. PA E120 Panic alarm High 46. PB E570 Panic bypass Low 47. PJ R375 Panic trouble restore Low 48. PR R120 Panic restore Low 49. PT E375 Panic trouble Low 50. PU R570 Panic unbypass Low 51. RB E416 Remote programming begin Low 52. RP E602 Automatic test / ring-in test Low 53. RR E305 Power up 54. RS R416 Remote programming success Low 55. RU R416 Remote programming fail Low 56. RX E601 Manual CS test Low ...C... 246 P/N 466-5261 • REV D ISS 17NOV17 System power-up UltraSync Modular Hub Reference Manual Low ©2016 United Technologies Corporation .. I ... .. . .. # 57. SIA code TA CID code Function E144 Tamper alarm E145 Tamper alarm E320 Tamper alarm Reporting priority Note Zone tamper Medium Medium Expander siren tamper Medium 58. TB E570 Tamper bypass Low 59. TR R144 Tamper restore R145 Tamper restore R320 Tamper restore Expander siren restore Low R370 Tamper restore KeyBox tamper restore Low Zone tamper restore Low Low 60. TT E370 KeyBox zone active High 61. TU R570 Tamper unbypass Low 62. UB E570 Expander / keypad / sensorbypassed Expander / keypad / zone isolated Low 63. UU R570 Expander / keypad / zone unbypassed Expander / keypad / zone de-isolated Low 64. WF E612 Walk test fail Low 65. WP E611 Walk test pass Low 66. XH R344 RF jamming restore Low 67. XQ E344 RF jamming Low 68. XR R384 Detector or fob low battery restore Low 69. XT E384 Detector or fob low battery Low 70. YC E350 Communications fail ISDN / GSM / voice / audio device fail Low 71. YK R354 Communications restore ISDN / GSM / voice / audio device restore Low 72. YR R302 System battery / fuse restore Expander / dialler battery / fuse restore Low 73. YS E354 Communication trouble Fail To Communicate (FTC) Low 74. YT E302 System battery / fuse trouble Expander / dialler battery low / fuse fault Low 75. ZA E152 Technical alarm — low temperature Low temperature detector alarm Medium 76. ZB E570 Technical bypass — low temperature Low temperature detector inhibit Low 77. ZJ R381 Technical long supervision restore — low temperature Low temperature detector long supervision Low restore 78. ZR R152 Technical restore — low temperature Low temperature detector restore 79. ZS E381 Technical long supervision — low temperature Low temperature detector long supervision Low alarm 80. ZU R570 Technical unbypass — low temperature Low temperature detector uninhibited 81. YA E321 Siren fault Low 82. YH R321 Siren restore Low ...C... 247 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual Low Low ©2016 United Technologies Corporation .. I ... .. . .. # SIA code CID code Function Reporting priority Note 83. NC E356 CS polling fail Heartbeat inactive Low 84. NR R356 CS polling restore Heartbeat active Low 85. CP R403 Auto set Set by schedule Low 86. OA E403 Auto unset Unset by schedule Low 87. OT E608 Late close Postponed auto set Low 88. OK R608 Early open Manually unset before auto unset Low 89. IA E313 Engineer reset request Low 90. IR R313 Engineer reset restore Low 91. GA E151 Technical alarm — gas Gas detector alarm High 92. GR R151 Technical restore — gas Gas detector restore High 93. GB E570 Technical bypass — gas Gas detector inhibit Low 94. GU R570 Technical unbypass — gas Gas detector uninhibit Low 95. GS E381 Technical long supervision — gas Gas detector long supervision alarm Low 96. GJ R381 Technical long supervision restore — gas Gas detector long supervision restore Low 97. KA E158 Technical alarm — high temperature High temperature detector alarm Medium 98. KR R158 Technical restore — high temperature High temperature detector restore Medium 99. KB E570 Technical bypass — high temperature High temperature detector inhibit Low 100. KU R570 Technical unbypass — high temperature High temperature detector uninhibit Low 101. KS E381 Technical long supervision — high temperature High temperature detector long supervision Low alarm 102. KJ R381 Technical long supervision restore — high temperature High temperature detector long supervision Low restore 103. WA E154 Technical alarm — water Water detector alarm Medium 104. WR R154 Technical restore — water Water detector restore Medium 105. WB E570 Technical bypass — water Water detector inhibit Low 106. WU R570 Technical unbypass — water Water detector uninhibit Low 107. WS E381 Technical long supervision — water Water detector long supervision alarm Low 108. WJ R381 Technical long supervision restore — water Water detector long supervision restore Low 109. ES E145 Tamper alarm Expander / keypad tamper alarm Medium 110. EJ R145 Tamper restore Expander / keypad tamper restore Medium 111. HV E129 Hold-up alarm confirm Medium 112. HW R129 Confirmed hold-up alarm restore Low ...C... 248 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. # SIA code CID code Function Reporting priority Note 113. UA E150 Technical zone — general alarm Medium 114. UR R150 Technical zone — general alarm restore Medium 115. TS E607 116. TE R607 117. LU R628 Local programming fail Low 118. YP E301 Power Supply Trouble Low 119. YQ R301 Power Supply Restored Low ...C... 249 Single zone walk test start Start of single zone test, also for multiple zones selected High Single zone walk test end End of single zone test, also for multiple zones selected Low P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. UL Specification General: The UL Listed system consists of the following features and compatible devices: Electrical: Software Version: 1.x Installation Notes: The system shall not be programmed to add input from the Web Server, UltraSync App, and Wi Fi to smartphone. The chime feature is only to be used in the disarm stage. It is not to be used as the main audible alarm. During the test mode, test AC and Battery every week by disconnecting AC power and verifying 5 minutes of emergency signaling. Reinstall restraining means of power plug. Replace the battery every xx years. The RF jamming signal is displayed on the keypad and repeats until code is entered. Compatible Receivers: Operation has been verified with industry standard SIA Contact ID format. It is the Installer’s responsibility to verify compatibility between the panel and the receiver used during installation. The Installer shall verify the compatibility of the receiver and the system on a yearly basis. Listings and Approvals: UL: ANSI/UL 985 Household Fire Warning ANSI/UL 1023 Household Burglar ANSI/UL 1637 Home Health Care Signaling cUL: ULC S545 – Residential Fire Warning System Control Units ULC/ORD-C1023 – Preliminary Standard for Household Burglar Alarm System Units SIA: ANSI/SIA CP-01-2010 False Alarm Reduction Minimum System Configuration: Control Panel UM-5000 for use with the following UL Listed accessories manufactured by UTC: TX-1012-01-1, TX-1012-01-3 DOOR CONTACT 60-362N-10-319.5 DOOR CONTACT TX-6010-01-1 SMOKE DETECTOR 60-848-02-95 SMOKE DETECTOR 60-703-95 PIR 60-639-95R PIR ...C... 250 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Abort: Consult with your Installer to determine if your system is configured with a communicator delay. A communicator delay will prevent a report to the central station if the control panel is disarmed within 30-45 seconds after an intrusion alarm is triggered. Note: Fire-type alarms are normally reported without a delay. Quick exit: Use the quick exit feature when someone wants to briefly leave while the home is still armed (for instance to get the newspaper). This feature needs to be enabled by your Installer. When you press the DISARM button, the display shows Exit Time is On. This allows a designated exit door to be open for up to two minutes without triggering an alarm. Note: The designated door may be opened and closed only once. If you close the designated door behind you when you exit, you will have to disarm the system upon reentering. Leave the designated door open while using the quick exit feature. Note: The designated door may be opened and closed only once. If you close the designated door behind you when you exit you will have to disarm the system upon reentering. Leave the designated door open while using the quick exit feature. Exit delay extension: If enabled by your Installer, the Exit Delay extension feature will recognize when you arm the system, leave your house and then quickly re-enter your house (such as you would if you forgot your car keys.) In such a case ZX-6400 will restart your exit delay to give you the full exit delay again. Exit Progress Annunciation: A pulsating audible sounds throughout the duration of the Exit Time to indicate that the exit period is in process. A rapid pulsating audible sounds during the last ten (10) seconds of the Exit Time to indicate that the Exit Time is running out. Entry Progress Annunciation: A pulsating audible sounds upon entry to indicate that the Entry Delay has begun. Remote Control Devices: UTC model 6001064-95R ...C... 251 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Keyfob operation / System Acknowledgement: Unlock button. Disarm the system. LED light momentary on and two squawks from the control panel Lock button. Arm the system. LED light momentary on and two squawks from the control panel Light button. Toggle system-controlled lights on/off (if programmed). Star button. As programmed in the system. When the battery is low, the LED light will not turn on when buttons are pressed, and the keyfob will not operate. Canceling and preventing accidental alarms: One of the biggest concerns you might have regarding your security system is causing an accidental alarm. Most accidental alarms occur when leaving the residence after arming the system or before disarming the system upon your return. Alarms are canceled by entering a valid master or user code within the minimum cancel window of five (5) minutes. After alarms are canceled, the system will be disarmed. ...C... 252 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Recent Closing: Enabled (2-minute window) Sensor Tripping Instructions: Sensor Door/window Action Open the secured door or window. Carbon monoxide alarm Press and hold the Test/Hush button (approximately 5 seconds) until the unit beeps two times, and then release the button. Glass break Test with an appropriate glass break sensor tester. Motion sensor Avoid the motion sensor field of view for 5 minutes, and then enter its view. Smoke Press and hold the test button until the system sounds transmission beeps. Keyfob Press and hold the Lock and Unlock buttons simultaneously for 3 seconds. Remote touchpad Press and hold the two Emergency buttons simultaneously for 3 seconds. ...C... 253 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. SIA CP-01-2010 Programmable Features This system is shipped with preset defaults to comply with the Security Industry Association CP-01 Standard. The relevant settings are listed below and should not be changed to maintain CP-01 compliance. FEATURE REQUIREMENT RANGE SHIPPING DEFAULT Exit Time Required (programmable) For full or auto arming: 45 sec. - 2 min. (255 sec. max.) 60 Seconds Progress Annunciation / Disable - for Silent Exit Allowed Exit Time Restart Required Option Auto Stay Arm on Unvacated Premises Required Option (except for remote arm) Exit Time and Progress Annunciation / Disable - for Remote Arm Individual keypads may be disabled All annunciators enabled For re-entry during exit time Enabled If no exit after full arm Enabled Allowed Option (for remote arm) May be disabled - for remote arming Enabled Entry Delay(s) Required (programmable) 30 sec. - 4 min. ** Abort Window – for Non-Fire Sensors Required Option May be disabled - by sensor or sensor type Abort Window Time – for Non-Fire Sensors Required (programmable) 0 sec. - 45 sec. ** Abort annunciation Required Option Annunciate transmitted Cancel Window Required Cancel Annunciation Required Option Annunciate transmitted Duress Feature Allowed Option No automatic derivative of another user code No duplicates with other user codes Disabled Cross Zoning Required Option Programming needed Disabled Programmable Cross Zoning Time Allowed Swinger Shutdown Required (programmable) Swinger Shutdown Disable Allowed Fire Alarm Verification Call Waiting Cancel ...C... 254 that 30 Seconds Enabled 30 Seconds no alarm was Enabled Minimum duration of the window shall be five (5) minutes. that a Cancel was May Program Enabled Per manufacturer For all non-fire sensors, shut down at 1 to 6 trips Two trips For non- police response sensors Enabled Required Option Depends on panel and sensors Disabled Required Option Depends on user phone line Disabled P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Smoke and heat detector locations: Selecting a suitable location is critical to the operation of smoke alarms. Figure 2 shows some typical floorplans with recommended smoke and heat detector locations. Use these location guidelines to optimize performance and reduce the chance of false alarms: Before mounting alarms, program (learn) them into memory and do a sensor test from the alarm’s intended location to ensure good RF communication to the panel. Locate the alarm in environmentally controlled areas where the temperature range is between 40 and 100°F (5 and 38°C) and the humidity is between 0 and 90% noncondensing. Locate alarms away from ventilation sources that can prevent smoke from reaching the alarm. Locate ceiling mounted alarms in the center of the room or hallway, at least 4 in. (10 cm) away from any walls or areas. Locate wall mounted alarms so the top of the alarm is 4 to 12 in. (10 to 31 cm) below the ceiling. In rooms with sloped, peaked, or gabled ceilings, locate alarms 3 ft. (0.9 m) down or away from the highest point of the ceiling. When mounting to suspended ceiling tile, the tile must be secured with the appropriate fasteners to prevent tile removal. Note: Do not mount the alarm to the metal runners of suspended ceiling grids. The metal runners can draw the magnet’s field away from the alarm’s reed switch and cause a false tamper alarm. Figure 2. Smoke and Heat Detector Locations: ...C... 255 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Product Warnings THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN EXPERIENCED SECURITY PROFESSIONAL. INTERLOGIX CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL SECURITY RELATED PRODUCTS. A PROPERLY INSTALLED AND MAINTAINED ALARM/SECURITY SYSTEM MAY ONLY REDUCE THE RISK OF EVENTS SUCH AS BREAK-INS, BURGLARY, ROBBERY OR FIRE; IT IS NOT INSURANCE OR A GUARANTEE THAT SUCH EVENTS WILL NOT OCCUR, THAT ADEQUATE WARNING OR PROTECTION WILL BE PROVIDED, OR THAT THERE WILL BE NO DEATH, PERSONAL INJURY, AND/OR PROPERTY DAMAGE AS A RESULT. WHILE INTERLOGIX MAKES REASONABLE EFFORTS TO REDUCE THE PROBABILITY THAT A THIRD PARTY MAY HACK, COMPROMISE OR CIRCUMVENT ITS SECURITY PRODUCTS OR RELATED SOFTWARE, ANY SECURITY PRODUCT OR SOFTWARE MANUFACTURED, SOLD OR LICENSED BY INTERLOGIX, MAY STILL BE HACKED, COMPROMISED AND/OR CIRCUMVENTED. INTERLOGIX DOES NOT ENCRYPT COMMUNICATIONS BETWEEN ITS ALARM OR SECURITY PANELS AND THEIR OUTPUTS/INPUTS INCLUDING, BUT NOT LIMITED TO, SENSORS OR DETECTORS UNLESS REQUIRED BY APPLICABLE LAW. AS A RESULT THESE COMMUNICATIONS MAY BE INTERCEPTED AND COULD BE USED TO CIRCUMVENT YOUR ALARM/SECURITY SYSTEM. BATTERY OPERATED SENSORS, DETECTORS, KEYFOBS, PANIC DEVICES AND OTHER PANEL ACCESSORIES HAVE A LIMITED BATTERY LIFE. WHILE THESE PRODUCTS ARE DESIGNED TO PROVIDE SOME WARNING OF IMMINENT BATTERY DEPLETION THE ABILITY TO DELIVER SUCH WARNINGS IS LIMITED AND SUCH WARNINGS MAY NOT BE PROVIDED IN ALL CIRCUMSTANCES. PERIODIC TESTING OF THE SYSTEM IN ACCORANCE WITH THE INSTRUCTIONS PROVIDED IN THE USER MANUAL IS THE ONLY WAY TO ENSURE ALL SENSORS, DETECTORS, KEYFOBS, PANIC DEVICES AND OTHER PANEL ACCESSORIES ARE FUNCTIONING PROPERLY. CERTAIN SENSORS, PANIC DEVICES AND OTHER PANEL ACCESSORIES MAY BE PROGRAMMED AS “SUPERVISORY” INTO THE ALARM PANEL MEANING THAT THE ALARM PANEL WILL INDICATE A TROUBLE IN THE EVENT IT DOES NOT RECEIVE A REGULAR SIGNAL FROM THE DEVICE WITHIN A CERTAIN PERIOD OF TIME (E.G. 12 HOURS). CERTAIN DEVICES CANNOT BE PROGRAMMED AS SUPERVISORY. DEVICES CAPABLE OF BEING PROGRAMMED INTO AN ALARM PANEL AS SUPERVISORY MAY NOT BE PROPERLY PROGRAMMED RESULTING IN A FAILURE TO REPORT TROUBLE WHICH COULD RESULT IN DEATH, SERIOUS INJURY OR PROPERTY DAMAGE. WARNING: DO NOT CONNECT MAINS VOLTAGE DIRECTLY TO ANY COMPONENT OF THE ULTRASYNC MODULAR HUB OTHER THAN AN APPROVED TRANSFORMER. DOING SO COULD DAMAGE THE COMPONENTS AND POSE AN ELECTRICAL HAZARD THAT COULD RESULT IN A FIRE OR CAUSE SERIOUS ELECTRICAL SHOCK OR LOSS OF LIFE. ...C... 256 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Warranty Disclaimers INTERLOGIX HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS, WHETHER EXPRESS, IMPLIED, STATUTORY OR OTHERWISE INCLUDING (BUT NOT LIMITED TO) ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS SECURITY PRODUCTS AND RELATED SOFTWARE. INTERLOGIX FURTHER DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE UNIFORM COMPUTER INFORMATION TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY ANY STATE. (USA only) SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE. INTERLOGIX MAKES NO REPRESENTATION, WARRANTY, COVENANT OR PROMISE THAT ITS SECURITY PRODUCTS AND/OR RELATED SOFTWARE (I) WILL NOT BE HACKED, COMPROMISED AND/OR CIRCUMVENTED; (II) WILL PREVENT, OR PROVIDE ADEQUATE WARNING OR PROTECTION FROM, BREAK-INS, BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK PROPERLY IN ALL ENVIRONMENTS AND APPLICATIONS. Disclaimer THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. UTC ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS AND SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE LATEST DOCUMENTATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW.INTERLOGIX.COM This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental. The illustrations in this manual are intended as a guide and may differ from your actual unit as UltraSync is continually being improved. Intended Use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation. For the latest product information, contact your local supplier or visit us online at www.interlogix.com The system should be checked by a qualified technician at least every 3 years and the backup battery replaced as required. Copyright © 2016 United Technologies Corporation. All rights reserved. Trademarks and Patents All trademarks are the property of their respective owners. Interlogix, UltraSync name and logo are trademarks of United Technologies Corporation. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. IOS is the registered trademark of Cisco Technology, Inc. Android, Google and Google Play are registered trademarks of Google Inc. iPhone, Apple, iTunes are registered trademarks of Apple Inc. App ...C... 257 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Store is a service mark of Apple Inc. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Manufacturer Placed on the market by: UTC Fire & Security Americas Corporation, Inc. 3211 Progress Drive, Lincolnton, NC, 28092, USA Contact Information For contact information, visit us online at www.interlogix.com. Customer Support For technical support, see www.interlogix.com/support Certification Compliance labelling should be removed or adjusted if non-compliant configurations are selected. Advisory messages Advisory messages alert you to conditions or practices that can cause unwanted results. The advisory messages used in this document are shown and described below. WARNING: Warning messages advise you of hazards that could result in injury or loss of life. They tell you which actions to take or to avoid in order to prevent the injury or loss of life. Caution: Caution messages advise you of possible equipment damage. They tell you which actions to take or to avoid in order to prevent the damage. Note: Note messages advise you of the possible loss of time or effort. They describe how to avoid the loss. Notes are also used to point out important information that you should read. ...C... 258 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Regulatory Notices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by UTC Fire and Security could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. ...C... 259 P/N 466-5261 • REV D ISS 17NOV17 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. Index Click on entries to navigate A Action Events Category and Types ................... 218 Action Results Category and Event Types ........ 219 Actions Submenus ............................................. 123 Add a Camera Manually .................................... 168 Add a Camera, Automatic Discovery ................... 76 Add Camera to UltraSync .................................. 195 Add Users .......................................................... 171 Adding Cameras to the Network ..................194–95 Advanced Installation Using Web Server ............ 79 Advanced Programming, Actions ...................... 122 Advanced Programming, Area Groups .............. 149 Advanced Programming, Areas ........................... 96 Advanced Programming, Arm-Disarm ............... 127 Advanced Programming, Cameras ................... 168 Advanced Programming, Channel Groups ........ 161 Advanced Programming, Communicator........... 111 Advanced Programming, Devices / Enrollment . 129 Advanced Programming, Event Lists ................ 160 Advanced Programming, Holidays .................... 151 Advanced Programming, Menus ....................... 150 Advanced Programming, Network Servers ....... 169 Advanced Programming, Permissions .............. 145 Advanced Programming, Reporting and Notifications ................................................... 107 Advanced Programming, Scenes ...................... 166 Advanced Programming, Schedules ................. 120 Advanced Programming, Sensor Options ......... 156 Advanced Programming, Sensor Types ............ 152 Advanced Programming, Sensors ....................... 92 Advanced Programming, Speech Tokens ......... 168 Advanced Programming, System ........................ 81 Appendices ........................................................ 207 Area Groups Submenus .................................... 149 Areas Configuration menu ................................... 58 Areas Submenus ................................................. 96 Arm Disarm Submenus...................................... 127 Arming and Disarming ....................................... 201 B Batteries ............................................................... 26 C Cable Requirements ............................................ 28 Calculating Maximum Bus Cable Length........... 223 Calculations, Aux Current & Battery Capacity ... 230 Camera Setup Instructions ................................ 191 Camera Wi Fi Signal Strength ........................... 192 Cameras Submenus .......................................... 168 Cellular Module .................................................... 26 Cellular Radio Setup .......................................... 179 Change Default Camera Settings ...................... 199 Channel Configuration Menu ............................... 64 Channel Groups Submenus .............................. 161 Channels Submenus ......................................... 107 Check Cell Radio Signal Strength ..................... 183 Check Event History ............................................ 77 Check LAN Connection to UltraSync Servers ..... 38 Check System Connection Status ....................... 78 ...C... 260 P/N 466-5261 • REV D ISS 17NOV17 Choose a Location ...............................................27 Communicator Submenus .................................111 Connect to xGen Web Server over LAN ..............34 Connect using DLX 900 on LAN ..........................40 Connect using DLX900 on UltraSync ..................40 Connect via UltraSync App ..................................36 Control Devices..................................................130 Control Output 1.................................................131 Control Output 2.................................................131 Control Output 3.................................................132 Control Output 4.................................................132 Control Output 5.................................................132 Control Outputs ..................................................131 CPU .......................................................................9 CPU Power Input Specifications ........................228 Current Consumption .........................................229 Customize Reporting Codes ..............................163 D Deleting Devices ................................................136 Devices Submenus ..........................................130 Devices, Control.................................................130 Devices, Interlogix Transmitters ........................143 Devices, Keypad ................................................137 Devices, Output Expansion Modules ...............141 Devices, Zone Expansion M odules ..................140 Devices, Z-Wave................................................144 Diagram Wiring ....................................................30 Diagram, LED ......................................................32 Diagram, Terminal ...............................................31 DLX900 Software ...............................................207 E Email Reporting .................................................110 Enrollment ..........................................................134 Enrollment, Manual ............................................135 Environmental ....................................................231 Event ID Table ...................................................215 Event Lists Submenus .......................................160 Event Reporting Class Table .............................217 Example Sensor or Area Event .........................162 Example System Event ......................................162 Expander Installation .........................................177 F Features & Benefits ...............................................7 Ferrite Installation ..................................................30 Firmware upgrade using DLX900 ......................210 Force Arming, Bypass, and Auto-Bypass ..........100 Fuses .................................................................231 G Glossary .............................................................203 Grounding ............................................................28 H Hardware Installation ...........................................27 History Events ....................................................215 Holiday Configuration Menu ................................73 Holidays Submenus ...........................................151 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . .. I Install Optional Cellular Radio ........................... 179 Install UltraSync App ........................................... 43 Interlogix Transmitters ....................................... 143 K Key Fob Configuration Menu ............................... 56 Keypads ............................................................. 137 Keypress Tamper .............................................. 201 L LAN Wiring and Topology .................................... 21 Learn in a Keyfob ................................................. 54 Learn in Sensors .................................................. 49 Live Stream and Latest Clip............................... 197 Lock PIN Share .................................................... 75 M Maintenance ...................................................... 231 Manually Assign IP Address ................................ 34 Menus Submenus .............................................. 150 Messages, App and Web Error ......................... 213 Messages, System Status ................................. 212 Messages, Z-Wave ............................................ 214 Minimum System Requirements .......................... 27 N Network Configuration Menu ............................... 66 P Permissions ....................................................... 174 Permissions Submenus ..................................... 145 Physical Dimensions .......................................... 231 Power Requirements ........................................... 27 Power Supplies .................................................. 143 Program Event Triggered Camera Clips ........... 197 Programming Areas ............................................. 57 Programming Cameras........................................ 76 Programming Holidays ........................................ 73 Programming Methods ........................................ 33 Programming Reporting and Notifications ........... 63 Programming Relay Expansion Modules .......... 141 Programming Scenes .......................................... 68 Programming Schedules ..................................... 71 Programming the Network ................................... 65 Programming the System .................................... 60 Programming via On-Site Keypad ....................... 41 Programming via UltraSync ................................. 35 Programming via Web Server ............................. 34 R Recommended Items to Change ......................... 41 Relay Expansion Modules ................................... 14 Removing a Camera .......................................... 168 Replacing Devices ............................................. 135 Reporting Fixed Codes in Contact I.D. .............. 165 Retrieve IP address ............................................. 34 S Scene Action Event Type .................................. 167 Scene Configuration Menu .................................. 70 Scene Configuration Sequence ........................... 68 Scenes Submenus ............................................. 166 ...C... 261 P/N 466-5261 • REV D ISS 17NOV17 Schedules Configuration Menu............................72 Sensor Configuration Menu .................................53 Sensor Options Submenus ................................156 Sensor Options Table ........................................159 Sensor Submenus ...............................................95 Sensor Types Submenus ..................................152 Sensor Types Table ...........................................155 Service and Test Options ....................................88 Set Up a Web Access Passcode .........................35 Set Up Camera Ethernet/Wi Fi ..........................191 Shielding ..............................................................28 SIA and CID Reporting Code Descriptions ........232 SIA CP-01-2010 Programmable Features .........241 Smart Power Supply ............................................20 Specifications .....................................................228 System Building Blocks .....................................220 System Capacity ....................................................7 System Clock .......................................................82 System Components .............................................9 System Configuration Menu ................................62 System Counters .................................................91 System Devices .................................................129 System General Features ..................................228 System General Options ......................................83 System Menu Tree ............................................223 System Monitoring .............................................231 System Settings ...................................................49 System Siren Options ..........................................87 System Status ......................................................89 System Timers .....................................................84 T Termination Jumpers ...........................................28 Touch Screen Keypad .........................................11 Troubleshooting Camera ...................................200 Troubleshooting DLX900 ...................................209 Troubleshooting LAN Connections ......................35 Troubleshooting UltraSync Setup ........................39 U UL Specification .................................................237 UltraSync App ......................................................43 UltraSync Color Codes ........................................47 UltraSync Touch Screen ....................................185 Users and Permissions ......................................171 Users Submenus ...............................................173 Using the UltraSync App ......................................44 V View event triggered clips in History ..................199 Viewing Cameras in UltraSync ............................76 Voice Library Table ............................................211 W Web Access Passcode ........................................41 Wireless Expansion Modules...............................16 Z Zone and Wireless Expansion Modules ............140 Zone Expansion Modules ....................................12 Zone Start and End ............................................140 Z-Wave Devices.................................................144 UltraSync Modular Hub Reference Manual ©2016 United Technologies Corporation .. I ... .. . ..
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Steve Wilson Create Date : 2018:02:08 13:57:44+11:00 Modify Date : 2018:02:22 16:27:22-07:00 Language : en-AU Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Creator : Steve Wilson Creator Tool : Microsoft® Word 2010 Metadata Date : 2018:02:22 16:27:22-07:00 Producer : Microsoft® Word 2010 Document ID : uuid:83bea1a0-1520-47e9-bbf2-16f21cb03c73 Instance ID : uuid:6fb1c17b-ad76-44bf-b47a-bdbcfb2b5d45 Page Count : 261EXIF Metadata provided by EXIF.tools