Intermatic 05200422 Home Pool/Spa Monitor User Manual Exhibit D Users Manual Part 2 per 2 1033 b3

Intermatic Inc Home Pool/Spa Monitor Exhibit D Users Manual Part 2 per 2 1033 b3

Contents

Exhibit D Users Manual Part 2 per 2 1033 b3

Download: Intermatic 05200422 Home Pool/Spa Monitor User Manual Exhibit D Users Manual Part 2 per 2 1033 b3
Mirror Download [FCC.gov]Intermatic 05200422 Home Pool/Spa Monitor User Manual Exhibit D Users Manual Part 2 per 2 1033 b3
Document ID638262
Application IDV4uCBOqjbjM7DALl8N3ItQ==
Document DescriptionExhibit D Users Manual Part 2 per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize278.29kB (3478580 bits)
Date Submitted2006-03-20 00:00:00
Date Available2006-03-20 00:00:00
Creation Date2006-03-20 10:33:01
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2006-03-20 10:33:23
Document TitleExhibit D Users Manual Part 2 per 2 1033 b3
Document CreatorAdobe InDesign CS2 (4.0.2)

26
I-Wave Installation Guide
Identifying Connections and Selecting Proper Input Voltage
Figure 4-2 below shows the reverse side of the Three-Circuit Clock Control Panel. Detailed
connection information is provided below the diagram.
CAUTION: If the Source Voltage Selector Jumper is in the wrong position, the F1
fuse will blow and you may damage the circuit board, voiding the warranty.
1. Before making any connections: Set the Source Voltage Selector Jumper.
The factory default position for this jumper is the 240 Volt position.
2. If the input voltage for the clock is 120 Volts, change this jumper to the
120 Volt position.
Heater Fireman Switch
Connection
Freeze Probe
Connection
Source Voltage
Selection Jumper
Wired or Wireless
Remote Control
Connection
Figure 4-2
Connection Detail
• Freeze Probe Connection — For the Intermatic Freeze Sensor (178PA0001A), which is
necessary for the freeze protection circuit and programming to work. Disconnect power when
connecting the freeze sensor. Only an Intermatic sensor can be used. Refer to page 34 for
programming information.
• Heater Firemen Switch Connection — For the firemen switch wires that connect to the Pool/
Spa heater. If installing with a Wireless Remote Control, use the two brown wires coming
from the panel-mounted antenna to create the circuit between this switch and the heater.
Connectors should be ¼” female spade connectors crimped to insulated-type wire. This
connection is a simple SPST contact, and switches the supplied heater voltage. It does not
supply voltage to the heater thermostat. In non-wireless installations, clip the “loop” supplied,
then connect with wire nut connectors. Refer to page 33 for programming information.
• Remote Control Connection — For the Intermatic Remote Control (133PE1484A), which
allows you to remotely turn On or Off all three available circuits. It also has status lights that
indicate when a load is On, Off or delayed. If using the Three-Button Wired Remote Control
(133PE1484A), it connects here as well.
Copyright © 2006 Intermatic, Inc.
Four: Programming the Three-Circult Clock Mechanism
27
Circuit Ratings
CLOCK SOURCE VOLTAGE — 120/240VAC, 50/60 Hz.
POWER CONSUMPTION — 6.0 Watts Max.
CIRCUIT CONTACT CONFIGURATION — SPST
CIRCUIT SWITCH RATINGS ALL MODES:
• 20A Resistive, 120/240 VAC., 50/60 Hz
• 20A FLA@120 VAC, 96A LRA@120 VAC, 50/60 Hz
• 17A FLA@240 VAC, 80A LRA@240 VAC, 50/60 Hz
• 5 Amps Tungsten, 120/240 VAC, 50/60 Hz
• 5 Amps Ballast, 120/240 VAC, 50/60 Hz
EVENTS PER CIRCUIT — 3 On/Off Events Per Circuit
INTERNAL BATTERY POWER
• 40 Year retention for all programmed settings
• Up to 24-hours
Mode Selection/Definition
IMPORTANT NOTE—There are five modes to choose from, depending on your
pool or spa equipment pad configuration. Each mode has specific programming,
timing, and lockout features that are designed to work with specific types of pool
or spa equipment. Mode setting is generally done only once and usually during the
initial installation. It is purposely difficult to enter the mode-changing program
and should only be done by a Qualified Installer. Be sure you fully understand each
mode definitions and installation, prior to selecting the proper mode.
Mode 1 — (Aux1, Aux2, Aux3)
Each of the three single pole circuits are defined
generically, and can control any load within each
of its individual circuit ratings. All three circuits act
independent of each other.
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
Figure 4-3
Providing a brighter solution.™
28
I-Wave Installation Guide
Mode 2 — (Pump High, Pump Low, Aux3)
Circuit one and two are dedicated single pole
outputs for a two-speed pump load. Circuits one and
two will never be ON at the same time, consistent
with a two-speed pump application. Circuit
three is single pole circuit for a generic load, and
independent of circuits one and two..
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
Figure 4-4
Mode 3 — (Pump, Aux2, Cleaner Pump)
Circuit one and three are dedicated single pole
outputs for a single speed pump working with a
pressure side cleaner pump. Circuit three will never
come on unless circuit one is on for at least one
minute, consistent with a pressure side cleaner
pump. Circuit two is a single pole circuit for a
generic load, independent of circuits one and three..
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
Figure 4-5
Copyright © 2006 Intermatic, Inc.
Four: Programming the Three-Circult Clock Mechanism
Mode 4 — (Pump High, Pump Low, Cleaner Pump)
Circuit one and two are dedicated single pole
outputs for a two-speed pump load. Circuits one and
two will never be ON at the same time, consistent
with a two-speed pump application. Circuit three
is also a dedicated single pole output for a pressure
side cleaner pump. Circuit three will never come
on unless circuit one is on for at least one minute,
consistent with a pressure side cleaner pump.
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
Figure 4-6
Mode 5 — (Pump, Pump, Aux3)
Circuit one and two are now coupled together
making up one circuit capable of switching the
power source to one pump. The On/Off button for
circuit one now controls both circuit one and two
simultaneously. The On/Off button for circuit two is
disabled. Circuit three remains a single pole circuit
for a generic load, and is independent of circuits one
and two..
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
Figure 4-7
Providing a brighter solution.™
29
30
I-Wave Installation Guide
Setting Mode
Overview
Determine the mode that would be best for your installation, then select it using the instructions
provided below.
 button
Procedure
“SET MODE”
 button
NOTE: If you don’t press a button within 60 seconds
while setting Mode, the control will save current
settings and return to normal operating mode.
1. With a small pointed tool (i.e., pen, pencil,
screwdriver, etc.,), press and hold the 
button for about 5 seconds until the display
shows SET MODE and the Mode Number
blinks.
2. Use the  buttons to cycle through all
five available modes. Each circuit output will
be defined on the display as you cycle through
the available modes.

buttons
Circuit outputs will
be defined
3. Once the desired mode number is displayed,
press and release the  button. This
saves the mode number to memory and exits SET MODE programming.
Mode
Number
blinks
Setting Time of Day
Overview
This procedure makes sure that timer-controlled actions will occur at the right time.
Program Menu
Procedure
NOTE: If you don’t press a button within 60 seconds
while setting Time of Day, the control will save
current settings and return to normal operating mode.

button
AM/PM Indicator
Displayed Time
1. Press and release the  button. The
displayed time will start to blink, and the program
menu will display Set Clock.
2. Use the  buttons to change the time.
NOTE: Check the AM and PM indicator to make
sure your setting is correct.
3. When the time is set, you have two choices:

buttons
• Press and release the  button to save and exit programming.
• Press and release the  button to save and go on to the next programming
feature.
Copyright © 2006 Intermatic, Inc.
Four: Programming the Three-Circult Clock Mechanism
31
Setting the On/Off Times for Each Circuit
Overview
You can set up to three separate ON/OFF times per load or circuit, and you can set specific times
for them to turn on and off, i.e., you want the filter pump to run from noon till 4:00 P.M., or you
want lights on from 7:00 P.M., off at 11:00 P.M., then on again at 6:00 A.M. and off at 8:00 A.M.
Procedure
PROGRAMMING TIP: You can use the  button to review all the events for each circuit.
You can use the  button to advance through each circuit and on to the next
programming feature.
1. If you pressed and released the program key from the
previous procedure, the screen display should look
like the illustration at the right. [If not, press and
release the  button twice.]
Note that the display indicates that the first event of
circuit one has not been defined (NO EVENT1).
NO EVENT 1
Not defined
2. Use the  buttons to define the Start time for
the first event (EVENT1) for circuit one. The screen
displays:
First Event
(EVENT1)
Start Time
3. Once you are satisfied with the start time, press and
release the  button, saving the start time. The
display will prompt for the Stop time for the first event
(EVENT1) for circuit one. The screen displays:
First Event
(EVENT1)
4. Use the  buttons to define the Stop time
for the first event (EVENT1) for circuit one. Press
and release the  button when complete.
The program will now advance to the second event
(EVENT2) for circuit one, as shown below. Note that
the display indicates that the second event of circuit
one has not been defined (NO EVENT2).
5. Repeat Steps 2 thru 4 to set a second event for circuit
#1, and for subsequent events you wish to set up.
Providing a brighter solution.™
NO EVENT 2
Stop Time
32
I-Wave Installation Guide
Notes on Setting On/Off Times for Each Mode
General Note
• The ON/OFF buttons were provided for service operations, and for circumstances where
instantaneous response is required. If the intent is to turn equipment on and off everyday at
the same time, programming individual events will make sure these functions take place.
• All circuits will respond to a programmed off time. Therefore, when a circuit is turned on with
the ON/OFF button, it automatically turns itself off at the end of the next programmed event.
• If there are no events programmed, the circuit stays on until the ON/OFF button is pressed
again.
• If the ON/OFF button is pressed while the corresponding circuit is on, it turns the circuit
off and supersedes any program in progress. The priority is always given to the last manual
operation.
Mode 1 — (Aux1, Aux2, Aux3)
All three of the available circuits act independently, and up to three individual on/off times can
be set for each circuit independently.
Mode 2 — (Pump High, Pump Low, Aux 3)
In this mode circuits 1 & 2 are connect to a two speed pump, and Aux 3 is connected
independent of circuits 1 & 2. In the event that you program high and low speed to be on at the
same time or if their independent ON times overlap, high speed will always take precedence.
Example: Low speed is programmed to come ON at noon and run until 6 PM. High speed is
programmed to come on at 2 PM and turn off at 4 PM. In this case the pump will come ON
at noon in low speed, go to high speed at 2 PM, and back to low speed at 4 PM, and shut off
at 6 PM.
All manual ON operations for circuits 1 & 2 override all programmed ON times. Therefore, any
desired low and high-speed run combinations need to be programmed as separate events and
cannot controlled by combining the manual ON/OFF button with a scheduled event. The last
speed started manually has priority over all prior automatic and manual operations.
Example: You would like to run the pump in high speed for 6 hours and low speed for the
remainder of the time. Program a 6-hour event for high speed, and an 18-hour event for low
speed. Do not turn the low speed on manually, and program a 6-hour event for high speed.
The high speed will not occur.
Mode 3 — (Filter Pump, Aux2, Cleaner Pump)
The cleaner pump cannot turn on unless the filter pump has been on for at least 30 seconds.
Therefore, for any ON/OFF time programmed for the cleaner pump, the filter pump will come on
first, followed 30 seconds later by the cleaner pump. Both the cleaner and filter pump will turn
off according to the programmed off time. When programming an event for the cleaner pump, it
is not necessary to program a separate event for the filter pump, as it will automatically turn on
when the cleaner pump turns on at its next scheduled on time.
Copyright © 2006 Intermatic, Inc.
Four: Programming the Three-Circult Clock Mechanism
33
Mode 4 – (Pump High, Pump Low, Cleaner Pump)
Mode 4 is a combination of Modes 2 and 3, so refer above to Modes 2 and 3 for programming
specifics. Note that if the cleaner pump is programmed to come ON, the control will turn ON
the filter pump to high speed 30 seconds prior to turning the cleaner pump ON, even if the filter
pump is currently on in low speed.
Mode 5 – (Aux1, Aux3)
Both of the available circuits act independently, similar to Mode 1. Therefore you can set up to
three individual ON/OFF times for each circuit and they will act independently.
Setting the Heater’s Cool Down Time (optional)
Overview
The heater’s cool down time is a time defined by the programmer. This time is defined as the
additional time the pump will run, over and beyond the desired pump OFF time, to make sure
the heater is cooled down before shutting off.
If the heater were to stay on after the pump had shut off, the water in the pipe
could boil, damaging the system. Refer to heater manufacturer for specific time.
If a cool down time is programmed, the cool down cycle will occur in all cases, even if the user
turns off the pump. To override the cool down time, press and release the ON/OFF key a second
time during the cool down cycle. The cool down feature only applies to Circuit #1, in all modes.
Procedure
1. Use the  button to advance to the COOL
DOWN setting, as shown. The default cool down time
is zero.
COOL DOWN
 button
2. Use the  buttons to modify the cool down
time. The programming range is from zero to fifteen
minutes and no seconds.
3. When you’ve set the cool down time, press the
 button to save and exit, or the 
button to save and advance to the next programming feature.
The display will look like the example shown at the right
when the Heater’s Cool Down Time feature is activated. In
this example, the cool down time was set for 5 minutes,
and is in the process of counting down to zero, showing
minutes and seconds.
The AUX1 indicator is blinking, indicating that the Cool
Down feature is activated for Circuit #1. The Cool Down
feature only affects Circuit #1. When the countdown
display reaches zero, Circuit #1 will open and the time
display will change back to the time of day.
 buttons
Counting Down
AUX1 Indicator
Blinking
Minutes and Seconds
NOTE: You can override the Cool Down feature during countdown by pressing and releasing the
ON/OFF button associated with Circuit #1. This will end the cool down cycle and immediately
power off Circuit #1.
Providing a brighter solution.™
34
I-Wave Installation Guide
Setting Freeze Temperature (optional)
Overview
Freeze temperature programming will not appear unless the optional Intermatic Freeze Sensor
(178PA28A) has been installed. This is the only freeze sensor that will work with the P1353ME
Controller.
Power must be disconnected when connecting the 178PA28A sensor.
If Intermatic Freeze Sensor (178PA28A) has been installed, use the following procedure to
program freeze temperature.
Procedure
1. Use the  button to advance to the
Freeze Temp setting, as shown. The 1st Circuit and
32°F are the factory default settings.
Freeze Temp
2. Use the  buttons to modify the desired
freeze temperature trip point. The programming range
is 32° through 44° F.
3. After you have set the desired trip temperature, push
and release the desired ON/OFF button to indicate
which circuits should come ON when the trip temperature is reached.
32°F
1st Circuit
4. When programming is complete, , press the  button to save and exit, or the
 button to save and advance to the next programming feature.
The display will look like the example shown at the
right when the Freeze Control feature is activated. In
this example, the freeze sensor was connected, enabling
the Freeze Control feature. Circuits #1 and #3 were
programmed to come on during a Freeze condition.
AUX1 and AUX3 will blink, indicating that the control
has activated these two circuits due to a freeze condition.
Freeze
Aux #1 and #3
NOTE: You can override the circuits during a freeze condition by pressing and releasing the
corresponding ON/OFF buttons. This will turn the devices OFF. The override will only last one
hour, so if the freeze condition still exists after one hour, Circuits #1 and #3 will come back on.
NOTE: Freeze protection stays enabled until the outside air temperature exceeds the
programmed freeze temperature for more than one minute.
Copyright © 2006 Intermatic, Inc.
Five: Programming the Valve/Pump Switch Mechanism
35
Section 5:
Programming the Valve/Pump Switch
Mechanism
Overview of the Valve/Pump Switch Control Panel
Front View
ACTUATOR CONNECTION —
The Pump/Valve Switch
mechanism supports up to
three 24V valve actuators.
HEATER THERMOSTAT CONNECTOR — supports the three
wires from the heaters thermostat. The wires should be
marked Pool, Common, and Spa. The mechanism will
switch the thermostat when the actuators change.
WIRED OR WIRELESS
CONNECTOR will support
either the wired spa side
remote or the panel-mounted
wireless transceiver.
SERVICE BUTTONS —
allow you to operate the
mechanism at the panel.
POOL/SPA
THERMOSTAT SWITCH
— allows you to switch
between the pool and
spa thermostat or just
the spa only. In the spa
only mode, the pool
thermostat is disabled.
JUMPER BLOCK
CONFIGURATION — used
when a simple single-pole
single through switch
is going to be used in
conjunction with the Sensor
Line to control the Pool to
Spa Mech. This is the most
inexpensive way to achieve
total pool/spa automation.
DUAL-VOLTAGE TRANSFORMER
— is capable of being powered
with either 120V or 240V.
CIRCUITS 1 & 2 — The pool to spa mechanism
supports up to two auxiliary 3HP circuit loads. You
can have different source voltages for each circuit,
depending on your equipment requirements.
Providing a brighter solution.™
SENSOR LINE — allows the
mechanism to be controlled by
a single pole sing throw switch
(i.e. toggle switch, relay, wall
switch, etc.). See page xxx for
details.
36
I-Wave Installation Guide
Rear View
24VAC POWER-IN FOR PC
BOARD — The circuit board
for the Pump/Valve Switch
requires 24VAC power
from the transformer.
POOL/SPA SWITCH CONNECTION — located on the face of the Pump/
Valve Switch mechanism connects to the PC board at this point, and
allows you to switch between the pool and spa thermostat or just the
spa only. In the spa only mode, the pool thermostat is disabled.
EXTERNAL TIMER PLUG IN —
into the PC board at this point
to control relay #1. Please see
page xx for instructions on
using an external timer.
OMRON CONNECTIONS
— Each of the two Omron
relays connects to the PC
board at these points.
OMRON RELAY #1 — This
relay can switch either
120V or 240V loads. Can
be ordered separately (145T145A)
OMRON RELAY #2 — This
relay can switch either
120V or 240V loads.
Can be ordered separately
(145T145A)
CONTROL FACE PLUG IN — a
control pad for service. The
control pad connects to the
PC board at this point.
SENSOR LINE PLUG IN — The pool to spa mechanism
supports up to two auxiliary 3HP circuit loads. You
can have different source voltages for each circuit,
depending on your equipment requirements. The sensor line
allows the mechanism to be controlled by a single-pole
single throw switch. (i.e., a toggle switch, relay, wall switch, etc.)
Copyright © 2006 Intermatic, Inc.
Five: Programming the Valve/Pump Switch Mechanism
37
Installing the Three-Button Wired Remote Control
The Three-Button Wired Remote Control (133PE1484A) can be installed to
plug into either the Three-Circuit Clock (PE1353ME) or Valve/Pump Switch
(PE4243ME).
When plugged into one of these mechanisms, it replaces the wireless method
of controlling the three circuits within the mechanism. For example, if you plug Three-Button Wired
Remoe Control
the Three-Button Wired Remote Control into the Valve/Pump Switch, the two
(133PE1484A)
relays and the pool/spa control will no longer be controllable using the HandHeld Wireless Remote. The Three-Button Wired Remote Control must be installed where a third
mechanism is needed in the enclosure box, since the Wireless Hand-Held Remote. can only
control two mechanisms.
See illustrations below for connection detail.
Connection to
Valve/Pump Switch
(PE4243ME)
Connection to
Three-Circuit Clock
(PE1353ME)
Installing Other Wired Remote Connections (Master Switch)
You can install any ON/OFF switch to the sensor line to provide wired control of the two relays
and the Pool/Spa actuators in the Valve/Pump Switch (PE4243ME), giving you dual control
(master switch and wireless) control of these circuits.
In use, a wired remote switch toggles all circuits to their opposite state. This means that if
Relays 1 and 2 are ON, and the actuator valve is in SPA, the wired remote switch will turn
Relays 1 and 2 OFF, while switching the actuator valve to POOL. It does this by toggling
Relays 1 and 2 and the actuator valve back and forth from their default state in order to return
the system to its default setting after the owner has made temporary changes to the settings.
For example, if using the phone while sitting in the spa, the owner may turn off the jets to
reduce noise. The next time the Master Switch is used, the jets will revert to being ON when
the system is in spa mode.
INSTALLATION ISSUE: If you want to change the default state for your installation and you
manually press the switches on the Valve/Pump Switch control panel, your changes will be
temporary with the wired remote switch (master switch) because it will return the circuits to their
factory default setting when it is activated, eliminating your custom settings.
Therefore, if you want to make permanent changes to the factory
defaults, you must use the jumper, as shown at the right. Then the
wired remote switch’s return to defaults will not delete your changes.
• Putting the jumper on pins 1 and 2 sets the system default state
to OPEN = OFF. This is the factory default state.
• Putting the jumper on pins 2 and 3 sets the system default state
to CLOSED = ON.
Providing a brighter solution.™
38
I-Wave Installation Guide
Connecting the Heater Switch to Control Temperatures
Overview
The primary means of controlling the heater is using the Hand-Held Controller. If there is no
Hand-Held Controller in the system, the heater switch provides an alternate method.
This Switch can be also used in conjunction with the Hand-Held Controller to provide maximum
temperature limits for the pool and spa. Control by this Switch is primary over the Hand-Held.
Procedure
1. Wire the heater thermostats to the blue connectors visible
on the front of the Valve/Pump Switch, as shown.
2. Set limits on the heaters themselves, so that when
the Switch powers the heaters, they will reach the
temperatures you have set.
3. Make temperature adjustments at the heaters themselves.
If Connecting an External Timer:
Overview
You can add an external timer to a circuit, converting it from
“on-demand” control to timer control. External timers are
available from Intermatic but are not included with the IWave system. When connected to the system, the external
timer powers Relay 1 on and off according to its time
settings.
Procedure
Connect your timer to Relay 1 on the back of the Valve/
Pump Switch Mechanism, as shown in the circled area of
the illustration at the right.
Copyright © 2006 Intermatic, Inc.
Six: Programming the Hand-Held Transmitter
39
Section 6:
Programming the Hand-Held Remote
Transceiver
Overview
The Hand-Held Remote Tranceiver (PE950) is the focal point of user convenience. It’s waterresistant, shock-resistant, and is easy to program for handy remote control of the functions at a
specific pool-spa installation. An assortment of self-stick labels are provided to identify the
functions you program into the five control buttons. We suggest that you program the device first,
then apply the appropriate label from the assortment supplied.
Display Screen
Actuator
Button
(Pool/Spa)
ON/OFF
Function
Buttons
“OK” means
Hand-Held
is communicating
with panel-mounted
transceiver
(not currently
functional)
Up/Down
Arrow Buttons
When you see
these numbers, it means
that circuit is ON
STAT
OK
ºF
73
SET
P 73
S 85
POOL
SPA
“POOL” or “SPA”
tells which mode
the system is in
Temp settings
for pool (P)
or spa (S)
Current Temp
of the Pool or Spa,
depending on
whichever mode
the system is in
Detail on Hand-Held Remote Display Screen
Synchronizing the Hand-Held with the Receiver
When you’ve finished physical installation and wiring and have enabled power to the control
center, you need to synchronize the Hand-Held with the Panel-Mounted Transceiver. This is a
two step process: first, delete any programming that might exist in the Hand-Held Remote and
Receiver, then synchronize the two devices with each other.
Deleting Any Existing Programming
This procedure deletes any existing programming from the Remote and Receiver units so they are
ready to be programmed into the network of this installation.
NOTE: If the word FAILURE instead of SUCCESS appears at the bottom of the screen during any of
the following steps, repeat the programming procedure, then try replacing the batteries in the
Hand-Held. If the problem persists, contact Intermatic Customer Service.
1. Press any button on the Hand-Held Remote to wake it from sleep.
(The unit goes to sleep to conserve battery life when it has been idle
for 30 seconds.) The screen display on the Hand-Held looks like the
example on the right.
Providing a brighter solution.™
STAT
POOL
OO
ºF
SET
P OO
S OO
40
I-Wave Installation Guide
2. Press and hold the 

and buttons at the same time for about 5 seconds. This will put the device in programming mode, as shown at the right. 3. Press the <4> function button to select RESET CONTROLLER. The screen refreshes and displays only the line 4 RESET CONTROLLER, then returns to the full screen with the word SUCCESS at the bottom, as shown.. LEARN VER x RESET CONTROLLER 4. Now press the <3> function button on the Hand-Held Remote to select RESET NODE. The screen refreshes and displays only the line 3 RESET NODE. 5. Press the black button on the base of the Panel-Mounted Transceiver. The display returns to the full screen with the word SUCCESS at the bottom, as shown. The two devices are now “clean” and are ready to be linked together within the network you have installed. LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT SUCCESS LEARN VER x RESET NODE LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT SUCCESS Linking the Hand-Held Remote to the Receiver 1. If necessary, press any button on the Hand-Held Remote to wake it from sleep. (The unit goes to sleep to conserve battery life when it has been idle for 30 seconds.) The screen display on the Hand-Held looks like the example on the right. STAT OO ºF SET P OO S OO POOL 2. Press and hold the

and buttons at the same time for about 5 seconds. This will put the device in programming mode, as shown at the right. 3. Press the <1> function button to select INCLUDE NODE. The screen refreshes and displays only the line 1 INCLUDE NODE, as shown. Copyright © 2006 Intermatic, Inc. LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT LEARN VER x 1 INCLUDE NODE Six: Programming the Hand-Held Transmitter 4. Push the black button on the base of the Panel-Mounted Transceiver. The screen returns to the full screen with the word SUCCESS at the bottom, as shown. 5. Press the <2> function button to select ADD TO GROUP. The screen refreshes and displays only the line 2 ADD TO GROUP. 6. Push the black button on the base of the Panel-Mounted Transceiver. The screen returns to the full screen with the word SUCCESS at the bottom, as shown. 41 LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT SUCCESS LEARN VER x ADD TO GROUP LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT SUCCESS 7. Press the button on the Hand-Held Remote to exit programming mode. On the left side of the screen, you will see the words STAT OK. STAT OK The two devices are now linked together within the network you have installed. POOL OO ºF SET P OO S OO NOTE: If the two devices have not successfully reset or linked together — and you are seeing only the word STAT on the left side of the screen — it’s likely that old programming still exists in either device. Carefully repeat the two procedures above. If the problem persists, contact Intermatic Customer Service. Testing I-Wave Reception At the heart of the I-Wave system is Z-wave™ wireless technology, which makes it easy to add makes use of Transceiver Repeater Modules (HA04C) to ensure that no problems in reception occur. Signal reception between Hand-Held Controllers and the Control Center is affected by distance (about 100 feet, direct line of sight) and by physical obstacles (like brick walls or structures). However, by plugging in repeaters where necessary, it’s no problem to span distances or overcome obstacles. Test reception by walking around the yard with the Hand-Held Remote and look on he screen to see if there are any areas where STAT OK changes to STAT (which means the Hand-Held and the Control Center are no longer communicating). If you identify any location where you are Transceiver Repeater Module out of range, you need to install and configure a repeater between the (HA04C) location and the Control Center. Providing a brighter solution.™ 42 I-Wave Installation Guide Installing and Configuring Repeaters When Necessary 1. Plug a Transceiver Repeater Module (HA04C) into any electrical outlet that is located where you have determined a reception problem can be solved. 2. If necessary, press any button on the Hand-Held Remote to wake it from sleep. Because you are at a location in between the control center and the problem area, the screen display on the Hand-Held will look like the example on the right. STAT OK 72 ºF SET P 72 S 85 POOL 3. Press and hold the

and buttons at the same time for about 5 seconds. This will put the device in programming mode, as shown at the right. 4. Press the <1> function button to select INCLUDE NODE. The screen refreshes and displays only the line 1 INCLUDE NODE, as shown. 5. Push the black button on the Repeater. The word SUCCESS appears at the bottom of the Hand-Held’s screen as shown. 6. Press the <2> function button on the Hand-Held to select ADD TO GROUP. The screen refreshes and displays only the line 2 ADD TO GROUP. 7. Push the black button on the base of the Panel-Mounted Transceiver. The screen returns to the full screen with the word SUCCESS at the bottom, as shown. 8. Press the button on the Hand-Held Remote to exit programming mode. When you now carry the Hand-Held Remote in the problem area, you will now see the words STAT OK on the left side of the screen. LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT LEARN VER x 1 INCLUDE NODE LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT SUCCESS LEARN ADD TO GROUP LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT SUCCESS The repeater is now part of the network. You can add more repeaters as necessary. Copyright © 2006 Intermatic, Inc. VER x Six: Programming the Hand-Held Transmitter 43 Everyday Use of the Hand-Held Controller The complete everyday functionality of the pool/spa system you have installed can be conveniently controlled using the Hand-Held Remote. Changing between Pool and Spa The Valve Actuator (PE24VA) that you have installed in the system directs water either to the pool or the spa. To use the hand-Held Controller to control this valve: 1. Press any button on the Hand-Held Remote to wake it from sleep. (The unit goes to sleep to conserve battery life when it has been idle for 30 seconds.) The screen display on the Hand-Held looks like the example on the right. 2. Note on the Hand-Held Remote Screen the current mode for the system: STAT OK 72 ºF SET P 72 S 85 POOL • POOL on the left side of the screen indicates the pool temperature setting (shown in the example). • SPA on the right side of the screen indicates the spa temperature setting. 3. Press the

button. The system will change to the opposite mode from its current setting. 4. Note the change on the Hand-Held Remote Screen. In the example at the right, the mode is now changed to Spa, and the temperature shown is the water temperature of the Spa. NOTE: The large temperature display shown on the Hand-Held Remote Screen reflects the current water temperature of the Pool or Spa, depending on which mode is active. STAT OK 85 ºF SET P 72 S 85 SPA Setting Pool and Spa Temperatures If connected and linked, the Hand-Held Remote controls the independent water temperatures of both the pool and spa. 1. View the current temperature on the right side of the Hand-Held Remote Screen under the word SET. • P = current pool water set temperature • S = current spa water set temperature 2. Press the

button if necessary to change the system to Pool or Spa mode. 3. Press the or arrow buttons to raise or lower the setting to the desired temperature. You can hold the button down and the value will automatically change. 4. Release the arrow button when the setting reaches the temperature you want. After a few seconds, the display returns to the current temperature of the pool or spa, depending on which mode you select. Providing a brighter solution.™ 44 I-Wave Installation Guide Operating Programmed Functions Depending on how you have wired the system, the five function buttons on the Hand-Held Remote control the five circuits in the Control Center. You should apply the appropriate label to the five buttons — describing the appropriate equipment according to your installation — from the assortment of labels supplied. • Buttons <1>, <2>, and <3> control circuits 1, 2, and 3 on the Three-Circuit Clock Mechanism (P1353ME) that is installed on the left side of the Control Center. • Buttons <4> and <5> control Relay 1 and Relay 2 on the Valve/Pump Switch Control (P4243ME) that is installed on the right side of the Control Center. When you press any of these buttons, the appropriate circuit toggles ON or OFF. In addition, when the circuit is ON, the Hand-Held Controller’s display shows the circuit number along the top of the screen. Advanced Features Configuring Two or More Hand-Held Remote Controllers Many installations will find it convenient to use two Hand-Held Remote Controllers. Once you have linked one Hand-Held to the Control Center, it’s easy to add a second controller to the network. 1. Make sure the Hand-Held you are adding to the network has been reset, with any previous programming deleted. a. Press any button on the Hand-Held Remote to wake it from sleep. (The unit goes to sleep to conserve battery life when it has been idle for 30 seconds.) STAT OK 72 ºF SET P 72 S 85 POOL b. Press and hold the

and buttons at the same time for about 5 seconds. This will put the device in programming mode, as shown at the right. c. Press the <4> function button to select RESET CONTROLLER. The device resets and the word SUCCESS appears at the bottom of the screen. 2. On both Hand-Held units, press and hold the

and buttons at the same time for about 5 seconds to put them into programming mode, as shown at the right. Copyright © 2006 Intermatic, Inc. LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT SUCCESS LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT Six: Programming the Hand-Held Transmitter 45 3. On the Hand-Held you are adding to the network: a. Press the <5> button to select MORE OPTIONS. A new screen will appear, as shown at the right. LEARN VER x 1 MODE 3/4 2 READY FOR ADD b. Press the <2> button on the new screen to select READY TO ADD. The screen refreshes and displays only the line 2 READY TO ADD. 4. Promptly, on the Hand-Held that is already part of the network, press the <1> button to select INCLUDE NODE. After a few seconds, the word SUCCESS should appear on the screens of both units. 5. Press the button on both Hand-Held Controllers to exit programming mode. The left side of the screen of both Controllers will say STAT OK, indicating that the procedure has been successful. PREVIOUS OPTIONS EXIT LEARN VER x READY FOR ADD LEARN VER x 1 MODE 3/4 2 READY FOR ADD PREVIOUS OPTIONS EXIT SUCCESS NOTE: The first Hand-Held you link to the Control Center is considered the PRIMARY controller and all other units are SECONDARY. The PRIMARY controller must be used to “introduce” or link any additional Hand-Held units to the Control Center. Programming to Protect a Pool Cleaner Pump When you installed and wired the system, you may have included a cleaner pump along with a spa (Mode 3) or with a two-speed filter pump (Mode 4). You will want to make sure this pump is never powered on when the system is in spa mode. The system can accommodate these two scenarios. 1. Press any button on the Hand-Held Remote to wake it from sleep. (The unit goes to sleep to conserve battery life when it has been idle for 30 seconds.) STAT OK 72 ºF SET P 72 S 85 POOL 2. Press and hold the

and buttons at the same time for about 5 seconds. This will put the device in programming mode, as shown at the right. Providing a brighter solution.™ LEARN VER x 1 INCLUDE NODE 2 ADD TO GROUP 3 RESET NODE 4 RESET CONTROLLER 5 MORE OPTIONS C EXIT 46 I-Wave Installation Guide 3. Press the <5> button to select MORE OPTIONS. A new screen will appear, as shown at the right. 4. Press the <1> button on the new screen to select MODE 3/4 ON. LEARN VER x 1 MODE 3/4 2 READY FOR ADD PREVIOUS OPTIONS EXIT NOTE: This button toggles between ON and OFF. That’s all there is to it. When Mode 3/4 is set to ON: • The system will automatically turn the cleaner pump OFF any time the spa mode is activated, protecting the cleaner pump. • If the owner switches to pool mode or to the high-speed pump mode, the system waits 30 seconds before powering ON the cleaner pump, making sure there is adequate water in the system. Using Two Hand-Held Controllers to Operate the System When two or more Hand-Held Controllers are being used to operate a system, each will synchronize itself to the other according to whatever function the other controller has activated. For example, if you press the <1> button on one controller, the following will happen: • Circuit 1 at the control center will toggle on or off, depending on its current state. • The number 1 will appear along the top of the Hand-Held Controller’s screen. • Then, a few seconds later, the number 1 will also appear along the top of the second Hand-Held Controller’s screen. The owner can add up to 5 Hand-Held Controllers to a system. Manually Turning Equipment On and Off At the Control Center For service purposes, the five circuits and the pool/spa actuators can be operated manually at the Control Center. Simply press any of the circuit buttons on either the Three-Circuit Clock or the Valve/Pump Switch mechanisms to toggle between ON and OFF. Any manual OFF/ON controlling will be reflected on the screen of the Hand-Held Controller. Copyright © 2006 Intermatic, Inc. Seven: Checking Out System / Troubleshooting Section 7: Checking Out the System / Troubleshooting After you have completed installation and programming, make sure the system is working OK by completing the checklist below. Later on, if problems develop in using the system, this same checklist will help you troubleshoot the problem. When you finish checking each item, place a check mark in the box at the right. What to check How to run the check TROUBLESHOOTING — What to do if it doesn’t work Time of Day Setting Verify that display on Three-Circuit Clock Mechanism (P1353ME) is showing correct time of day. 1. Follow instructions for setting the correct time on page 30 of this manual. 2. Recheck that the set time is correct. Check circuits on the ThreeCircuit Clock Mechanism (P1353ME) 1. Press the first ON/OFF button on the face of the mechanism. 2. Verify that the Hand-Held Receiver shows that the circuit has powered on. 3. Verify that the wired function activates properly (e.g., a pump comes on). 4. Turn the circuit off using the appropriate button on the Hand-Held Remote. 5. Repeat with ON/OFF buttons two and three. If any of the circuits don’t work: 1. Check your wiring for the circuit. 2. Make sure you have set the correct Mode for the installation. See page 27 of this manual. 3. If the Hand-Held Remote fails to turn off the circuit, check its programming. See page 39 of this manual. Check circuits on the Valve/ Pump Switch Mechanism (P4243ME) 1. Press the RELAY 1 button on the face of the mechanism. 2. Verify that the Hand-Held Receiver shows that the circuit has powered on. 3. Verify that the wired function activates (e.g., a pump comes on). 4. Turn the circuit off using the appropriate button on the Hand-Held Remote. 5. Repeat with the RELAY 2 button. If any of the circuits don’t work: 1. Check your wiring for the circuit. 2. Make sure you have set the correct Mode for the installation. See page 27 of this manual. 3. If the Hand-Held Remote fails to turn off the circuit, check its programming. See page 39 of this manual. Check that the Actuator valves correct switch between pool and spa. 1. Press the VALVES button on the Valve/Pump Switch Mechanism (P4243ME). 2. Verify that the Hand-Held Receiver shows that the actuator valves have changed position. 3. Verify that the actuator valves have correctly switched position. 4. Switch the valves back using the P/S button on the Hand-Held Remote. If any of the valves don’t switch: 1. Check your wiring for the circuit. 2. If the Hand-Held Remote fails to turn off the circuit, check its programming. See page 39 of this manual. Check that the actuator valves are synchronized. As you watch them move back and forth, verify that the valves are oriented the same way: to pool, then to spa Re-synchronize the valves. See page 21 of this manual. Verify that the Hand-Held Remote is controlling pool and spa temperature. Providing a brighter solution.™ ✔ 47 48 I-Wave Installation Guide What to check Check that protection for pool cleaner pump is working. How to run the check TROUBLESHOOTING — What to do if it doesn’t work Mode 3 and 4 Check wireless reception all around the yard. If any dead spots are located, install Repeaters. See page 41 of this manual. Check that the Fireman’s Switch is working (if installed). 1. Press the ON/OFF button on the ThreeCircuit Clock Mechanism (P1353ME) to power OFF the pump. 2. Watch for the time display to count down the interval you have programmed. Re-program the Fireman’s Switch timing. See page 33 of this manual. Check that the Freeze Sensor is working (if installed). 1. Place the freeze sensor in a cup of ice. 2. Wait for the temperature of the sensor to approaches that of the ice. 3. Verify that the heater has come on. Re-program the Freeze Sensor. See page 34 of this manual. Check that the Three-Button Wired Remote Control is working (if installed) 1. Press each of the three buttons on the Wired Remote Control. 2. Verify that the functions controlled by those circuits activate properly. If any of the circuits don’t work, check your wiring for that circuit. Check that the External Timer is working (if installed) Copyright © 2006 Intermatic, Inc. ✔ Eight: Enclosure Specifications Section 7: Enclosure Specifications DY LA NEE UA RK RTW HI — AN IS J Suitable listed breakers (purchase locally) CIRCULT BREAKER MANUFACURER SINGLE DOUBLE TWIN QUAD GFCB Cutler-Hammer Murray Siemens Square-D Thomas & Betts BR MP-T QP HOM TB BR MP-T QP HOM TB BRD MH-T QT HOMT TBBD BRD MH-T QT HOMT TBBD BRD MH-T QT HOMT TBBD Providing a brighter solution.™ FILLER PLATE BRFP LX100FP QF3 HOMFP FP-1C-TB 49 50 I-Wave Installation Guide Section 9: Warranty ONE YEAR LIMITED WARRANTY If, within one (1) year from the date of purchase, this product fails due to defect in material or workmanship, Intermatic Incorporated will repair or replace it, as its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping, or abuse in handling, acts of God, or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LEDs, and batteries; (f) the finish on any portion of the product, such as surface and/or weatheriong, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs. INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AMND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATE ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage prepaid, to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/ After Sales Service/7777 Winn Rd., Spring Grove, IL 60081-7000 . Please be sure to wrap the product securely to avoid shipping damage. Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material contained herein, and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented. WARRANTY REGISTRATION Owner’s Name___________________________________ Signature_____________________________________________ Street Adddress_________________________________________ City__________________________________ State ______ Authorized Dealer _____________________________ City__________________________________ Date of Purchase ______________________________ Zip ______________ Phone __________________________ Sales Rep ____________________________ State _________ Zip ______________ Phone _______________________ How did you hear about our product? (Please check all that apply.) ___Pool Store Employee Friend/Relative ___Magazine ___Pool Builder ___Newspaper ___Radio ___Pool Service ___TV ___Direct Mail Ad ___Catalog ___ ___Other: _____________________________ To activate your warranty, please return this portion to: ___In-Store Display Intermatic, Inc. 7777 Winn Road Spring Grove, IL 60081 or by FAX: 815-675-7055 Copyright © 2006 Intermatic, Inc. Nine: Warranty 51 Installation Notes ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ Providing a brighter solution.™ Intermatic, Inc. 7777 Winn Road Spring Grove, Illinois 60081-9698 www.intermatic.com Intermatic Customer Service: 815-675-7000 (8 a.m. through 4:30 p.m. CT, Monday through Friday) ©2006 Intermatic, Inc. Printed in U.S.A. [code number]


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2006:03:20 10:33:23-06:00
Create Date                     : 2006:03:20 10:33:01-06:00
Creator                         : Adobe InDesign CS2 (4.0.2)
Producer                        : Adobe PDF Library 7.0
Page Count                      : 27
Mod Date                        : 2006:03:20 10:33:23-06:00
Creation Date                   : 2006:03:20 10:33:01-06:00
Metadata Date                   : 2006:03:20 10:33:23-06:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: DGZ05200422

Navigation menu