Intermatic CA3750 Multi-Voltage High Current Contactor Module User Manual CA3750

Intermatic Inc Multi-Voltage High Current Contactor Module CA3750

Exhibit D Users Manual per 2 1033 b3

Download: Intermatic CA3750 Multi-Voltage High Current Contactor Module User Manual CA3750
Mirror Download [FCC.gov]Intermatic CA3750 Multi-Voltage High Current Contactor Module User Manual CA3750
Document ID716147
Application IDdlYDKNa+6gAJWL3vCOxSwA==
Document DescriptionExhibit D Users Manual per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.05kB (300568 bits)
Date Submitted2006-10-16 00:00:00
Date Available2006-10-16 00:00:00
Creation Date2006-07-31 21:56:03
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2006-07-31 21:56:03
Document TitleCA3750.cdr
Document CreatorPScript5.dll Version 5.2

TM
Providing a Brighter Solution™
WIRELESS CONTROLS
This product is compatible with other Z-Wave™ enabled products
Model CA3750
Multi-Voltage High Current
Contactor Module
The CA3750 Multi-Voltage High Current Contactor Module is a Z-wave™ enabled device which is
fully compatible with any Z-wave enabled network. Z-wave enabled devices display the Z-wave
logo and guarantee connectivity and interoperability between devices. Each node in a Z-wave
network is designed to act as a repeater forming a mesh network eliminating radio “dead spots”
and providing the highest level of reliability.
Features
- Multiple location ON/OFF control of contactor when used with wireless controls.
- Multi-Voltage power supply 120, 208, 240, or 277 VAC
- Field configurable outputs 2 independently controllable SPST contacts or simultaneous DPST
contact operation.
- Up-front activator switch always operates load, does not require central control system.
WARNING: Read instructions completely before installation and retain for future reference.
WARNING: This device is not a motor disconnect.
WARNING: For installation and/or use in accordance with appropriate electrical codes and regulations.
WARNING: Consult a qualified electrician for installation and operation.
OTHER CAUTIONS:
1. For remote operation, use with Z-Wave compatible control for wireless control from any location.
2. Disconnect power when servicing or changing load.
3. Use this device only with 75°C rated copper or copper clad wire.
Note: For independent channel control requires presence of InTouch™ Server (CA5500B or other).
Specifications:
Local control via Activator Button
or Wireless RF Control
Operating Temperature Range:
14°F (-10°C) to 140°F (60°C)
Power Consumption: 6.0W Max
Ratings:
120, 208, 240, 277VAC, 50/60Hz
6600 Watts 30 A Resistive;
5500VA 25 A Inductive;
5540 Watts 20 A @ 277VAC Ballast;
4400 Watts 20 A Tungsten;
3HP @ 220VAC Motor
Enclosure:
NEMA 3R Indoor-Outdoor
Polycarbonate Case.
Connections:
1-Neutral/Line 2, 2-Line 1, 3 & 4
Contact 1, 5 & 6 Contact 2
RF Information:
Minimum Range:
50ft indoor; 100ft outdoor
Frequency: 908.42 MHz
Network Information:
Mesh Network - Each line powered
node acts as a repeater to route
distant signals.
Data Rate: 9600 bits/second
Size: 232 Z-Wave™ Nodes
INSTALLATION:
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER AND
TEST THAT POWER IS OFF BEFORE WIRING.
2. Follow all local electrical and safety codes, National Electric Code (NEC), as well as Occupational Safety
and Health Act (OSHA).
3. If the power disconnect point is out of sight, lock it in the “OFF” position and tag it to prevent unexpected
application of power.
4. Move fused jumper to proper source voltage selection 120, 208, 240, or 277 VAC.
5. Set contact selector switch for desired output. (1x DPST or 2x SPST)
6. Do not exceed the maximum current carrying capacity of this contactor module.
7. Always replace the plastic insulator covering the terminal before turning power “ON”.
8. Operation: Press activator button repeatedly to cycle contact operation; 2xSPST Mode: OFF:OFF,
ON:OFF; DPST Mode: OFF:OFF, ON:ON
7. For programming instructions refer to the InTouch Installer & Users Guide (158CA12789).
Status
LED
Program
Button
LINE/
NEUTRAL
Supply
Terminals
LINE
Input / Output
Terminals
158CA12473
TM
Providing a Brighter Solution™
WIRELESS CONTROLS
This product is compatible with other Z-Wave™ enabled products
FCC STATEMENT OF COMPLIANCE
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna or device.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
WARNING! Changes or modifications not expressly approved by Intermatic Inc. could void the user’s authority to operate the equipment.
Standard Installation
Line 2 /
Neutral
Line 2 /
Neutral
LOAD
Use jumpers only
if device voltage and
output voltage are
the same.
Use jumpers only
if device voltage and
output voltage are
the same.
LOAD
LOAD
Line 1
Line 1
Line 2 /
Neutral
Line 1
Line 2 /
Neutral
LOAD
Line 1
LOAD
LOAD
LIMITED TEN YEAR WARRANTY
If within ten (10) years from date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace, at its
sole option. This warranty applies only to the original purchaser and is not transferable. This warranty excludes and this is disclaimed liability for labor for
removal of this product or reinstallation. The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any
negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with
directions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you.
This warranty gives you specific legal rights and you may have other rights that vary from state to state. INTERMATIC INCORPORATED WILL NOT BE
LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES.
ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS
THE WARRANTY PERIOD STATED ABOVE.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing postage prepaid to the
nearest authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is made by:
Intermatic Incorporated, After Sales Service, 7777 Winn Road, Spring Grove, IL 60081-9698, 815-675-7000 www.intermatic.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:0fcda422-7c82-46d2-ac63-144088d884f3
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2006:07:31 21:56:03-05:00
Create Date                     : 2006:07:31 21:56:03-05:00
Document ID                     : uuid:c926845f-7142-4276-873d-41f255dbc099
Format                          : application/pdf
Title                           : CA3750.cdr
Creator                         : 
Author                          : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: DGZCA3750

Navigation menu