Intermatic CA3750 Multi-Voltage High Current Contactor Module User Manual CA3750
Intermatic Inc Multi-Voltage High Current Contactor Module CA3750
Exhibit D Users Manual per 2 1033 b3
TM Providing a Brighter Solution™ WIRELESS CONTROLS This product is compatible with other Z-Wave™ enabled products Model CA3750 Multi-Voltage High Current Contactor Module The CA3750 Multi-Voltage High Current Contactor Module is a Z-wave™ enabled device which is fully compatible with any Z-wave enabled network. Z-wave enabled devices display the Z-wave logo and guarantee connectivity and interoperability between devices. Each node in a Z-wave network is designed to act as a repeater forming a mesh network eliminating radio “dead spots” and providing the highest level of reliability. Features - Multiple location ON/OFF control of contactor when used with wireless controls. - Multi-Voltage power supply 120, 208, 240, or 277 VAC - Field configurable outputs 2 independently controllable SPST contacts or simultaneous DPST contact operation. - Up-front activator switch always operates load, does not require central control system. WARNING: Read instructions completely before installation and retain for future reference. WARNING: This device is not a motor disconnect. WARNING: For installation and/or use in accordance with appropriate electrical codes and regulations. WARNING: Consult a qualified electrician for installation and operation. OTHER CAUTIONS: 1. For remote operation, use with Z-Wave compatible control for wireless control from any location. 2. Disconnect power when servicing or changing load. 3. Use this device only with 75°C rated copper or copper clad wire. Note: For independent channel control requires presence of InTouch™ Server (CA5500B or other). Specifications: Local control via Activator Button or Wireless RF Control Operating Temperature Range: 14°F (-10°C) to 140°F (60°C) Power Consumption: 6.0W Max Ratings: 120, 208, 240, 277VAC, 50/60Hz 6600 Watts 30 A Resistive; 5500VA 25 A Inductive; 5540 Watts 20 A @ 277VAC Ballast; 4400 Watts 20 A Tungsten; 3HP @ 220VAC Motor Enclosure: NEMA 3R Indoor-Outdoor Polycarbonate Case. Connections: 1-Neutral/Line 2, 2-Line 1, 3 & 4 Contact 1, 5 & 6 Contact 2 RF Information: Minimum Range: 50ft indoor; 100ft outdoor Frequency: 908.42 MHz Network Information: Mesh Network - Each line powered node acts as a repeater to route distant signals. Data Rate: 9600 bits/second Size: 232 Z-Wave™ Nodes INSTALLATION: 1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER AND TEST THAT POWER IS OFF BEFORE WIRING. 2. Follow all local electrical and safety codes, National Electric Code (NEC), as well as Occupational Safety and Health Act (OSHA). 3. If the power disconnect point is out of sight, lock it in the “OFF” position and tag it to prevent unexpected application of power. 4. Move fused jumper to proper source voltage selection 120, 208, 240, or 277 VAC. 5. Set contact selector switch for desired output. (1x DPST or 2x SPST) 6. Do not exceed the maximum current carrying capacity of this contactor module. 7. Always replace the plastic insulator covering the terminal before turning power “ON”. 8. Operation: Press activator button repeatedly to cycle contact operation; 2xSPST Mode: OFF:OFF, ON:OFF; DPST Mode: OFF:OFF, ON:ON 7. For programming instructions refer to the InTouch Installer & Users Guide (158CA12789). Status LED Program Button LINE/ NEUTRAL Supply Terminals LINE Input / Output Terminals 158CA12473 TM Providing a Brighter Solution™ WIRELESS CONTROLS This product is compatible with other Z-Wave™ enabled products FCC STATEMENT OF COMPLIANCE This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna or device. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. WARNING! Changes or modifications not expressly approved by Intermatic Inc. could void the user’s authority to operate the equipment. Standard Installation Line 2 / Neutral Line 2 / Neutral LOAD Use jumpers only if device voltage and output voltage are the same. Use jumpers only if device voltage and output voltage are the same. LOAD LOAD Line 1 Line 1 Line 2 / Neutral Line 1 Line 2 / Neutral LOAD Line 1 LOAD LOAD LIMITED TEN YEAR WARRANTY If within ten (10) years from date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace, at its sole option. This warranty applies only to the original purchaser and is not transferable. This warranty excludes and this is disclaimed liability for labor for removal of this product or reinstallation. The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with directions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal rights and you may have other rights that vary from state to state. INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing postage prepaid to the nearest authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is made by: Intermatic Incorporated, After Sales Service, 7777 Winn Road, Spring Grove, IL 60081-9698, 815-675-7000 www.intermatic.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:0fcda422-7c82-46d2-ac63-144088d884f3 Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2006:07:31 21:56:03-05:00 Create Date : 2006:07:31 21:56:03-05:00 Document ID : uuid:c926845f-7142-4276-873d-41f255dbc099 Format : application/pdf Title : CA3750.cdr Creator : Author :EXIF Metadata provided by EXIF.tools