Intermatic CA7100 Master In-Wall Control Station User Manual CA7100

Intermatic Inc Master In-Wall Control Station CA7100

Exhibit D Users Manual per 2 1033 b3

WARNING: Read instructions completely before installation and retainfor future reference.WARNING:WARNING:OTHER CAUTIONS:For installation and/or use in accordance with appropriateelectrical codes and regulations.Consult a qualified electrician for installation and operation.1. For remote operation of Z-Wave compatible controls.2. Use this device only with copper or copper clad wire.Note: Designed to work only in the presence of InTouch™Server (CA5500B or other).Model CA7100Master In-Wall Control StationSpecifications:Ratings:Colors:Connections:RF Information:Network Information:Wireless RF Control120VAC, 50/60HzIncludes white snap-on face plate.Black-Line, White-Neutral,Green-GroundMinimum Range:50ft indoor; 100ft outdoorFrequency: 908.42 MHzMesh Network - Each line powerednode acts as a repeater to routedistant signals.Data Rate: 9600 bits/secondSize: 232 Z-Wave™ NodesOperating Temperature Range:32°F (0°C) to 104°F (40°C)Power Consumption: 4.0W MaxBacklit 128 x 64 Dot LCD DisplayINSTALLATION:1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER ANDTEST THAT POWER IS OFF BEFORE WIRING.Operation:2. Requires a 3-gang electrical junction box for installation.3. Remove t4. Attach mounting plate to 3-gang electrical junction box using (6) mounting screws furnished.5. Refer to wiring diagrams for proper connection of master in-wall control station.6. Check that all wire connections are secure and place all wires inside junction box.7. Replace master in-wall control station using (3) mounting screws. Complete installation by snapping coverplate back into place.8. Reconnect your electrical power.9. Press the “Enter” button to access setup menus. Press scene number button(s) to focuscontrol activities; Press “Enter” to toggle selected scene(s); Press10. For programming instructions refer to thehe face plate. Using a finger or thumb nail, remove the face plate from the housing body by liftingon the right edge by the menu navigation buttons. Remove exposed (3) screws to release mounting plate.(158CA12789).InTouch Installer & Users Guidevw/ to lower or raise selected scene(s)lighting level; Press the home key to clear selected scene(s).The CA7100 Master In-Wall Control StationEach line powered node in a Z-wave network is designed toact as a repeater forming a mesh network eliminating radio “deadspots” and providing the highest level of reliability.- Menu driven setup of scenes and events.- Built-in astronomic timing with real-time-clock backup.- Multiple location On/Off & Raise/Lower control when used with Z-wave enabled switches and dimmers.- Allows control of up to 100 individual pre-set scenes containing anynumber of Z-wave enabled devices.- Features 6 “Quick” pre-set scene activator buttons.- Features individual scene status feedback for enhanced control.- Separate focus and control buttons allows the user to custom mixscene selections and vary light levels.- Home key provides for quick de-selection of scenes and back-outfrom menu programming.is an enhanced radiofrequency controller compatible with Z-wave™ enabled networks anddevices.FeaturesFace Color ConversionThe face color of this device can be converted to match interior design requirements.1. Select and obtain the color of the face you desire.2. The face plate has snaps on 3 sides. Using a finger or thumb nail, remove the face plate from the housingbody by lifting on the right edge by the menu navigation buttons.3. Take the new face plate and position it properly to the housing body. Notice that the left edge has tabs thatmust be inserted first. Press the plate into position.4. The face plate snaps in with an audible click. Ensure that all snaps are secure.The color conversion is complete.FCC STATEMENT OF COMPLIANCEWARNING! Changes or modifications not expressly approved by Intermatic Inc. could void the user’s authority to operate theequipment.This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference, including interference that may cause undesired operation.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does causeharmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try tocorrect the interference by one or more of the following measures:-- Reorient or relocate the receiving antenna or device.-- Increase the separation between the equipment and receiver.-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-- Consult the dealer or an experienced radio/TV technician for help.Providing a Brighter Solution™158CA12474REFWIRELESS CONTROLSTM
WhiteStandard InstallationHot BlackNeutralWire Connector GroundGreen120VAC50/60 HzCA7100ENTER654321Speaker Scene Buttons Home ButtonMenuNavigationControlsBacklit 128 x 64Dot LCD DisplayENTER654321Wire Connector InstallationConnect wires as follows:Screw wire connectors on clockwise making sure nobare conductors show below the wire connector.Secure each connector with electrical tape.Insert wires straightthen twist clockwiseSecure each connnectorwith electrical tapeLIMITED TEN YEAR WARRANTYIf within ten (10) years from date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace, at itssole option. This warranty applies only to the original purchaser and is not transferable. This warranty excludes and this is disclaimed liability for labor forremoval of this product or reinstallation. The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or anynegligent use; (b) units which have been subject to unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance withdirections; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you.This warranty gives you specific legal rights and you may have other rights that vary from state to state.This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing postage prepaid to thenearest authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is made by:Intermatic Incorporated, After Sales Service, 7777 Winn Road, Spring Grove, IL 60081-9698, 815-675-7000 www.intermatic.comINTERMATIC INCORPORATED WILL NOT BELIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES.ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULARPURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION ASTHE WARRANTY PERIOD STATED ABOVE.For non-standard wiring applications, refer toWire Combination & Connector ChartOrange Wire Connector Combination Chart1- #14 AWG1 #14 AWGor1 #16 AWGor1-2 #18 AWG+1- #16 AWG1 #16 AWGor1-2 #18 AWG+2- #16 AWG1to2#18AWG+1- #18 AWG1to3#18AWG+Strip wires to expose3/8” of conductors3/8”CA7100 MasterIn-Wall Control PanelProviding a Brighter Solution™WIRELESS CONTROLSTM

Navigation menu