Itron 100GDLAS AMR transceiver device for utility meters User Manual 1

Itron Inc AMR transceiver device for utility meters Users Manual 1

Contents

Users Manual 1

Download: Itron 100GDLAS AMR transceiver device for utility meters User Manual 1
Mirror Download [FCC.gov]Itron 100GDLAS AMR transceiver device for utility meters User Manual 1
Document ID1771653
Application ID0F58Vuk05fSr3N+HG/dUfQ==
Document DescriptionUsers Manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize212.91kB (2661328 bits)
Date Submitted2012-08-21 00:00:00
Date Available2012-08-23 00:00:00
Creation Date2012-07-11 10:49:18
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2012-07-11 10:49:57
Document TitleUsers Manual 1
Document CreatorMicrosoft® Office Word 2007

Natural Gas Solutions
100G DLS Gas ERT Module Installation
Guide, Direct Mount
TDC-0823-009
Identification
100G DLS Gas ERT Module Installation Guide, Direct Mount
17 April 2012 TDC-0823-009
100G, 100G DL, 100G DLN, 100G DLS
ERT module part numbers:
100G ERT: ERG-5000-001, ERG-5000-002, ERG-5000-003, ERG-5000-004, ERG-5000-005, ERG-5000-006, ERG-5000-007, ERG-5000-008
100G Datalogging ERT: ERG-5002-001, ERG-5002-002, ERG-5002-003, ERG-5002-004, ERG-5002-005, ERG-5002-006, ERG-5002-007, ERG-5002-008
100G Datalogging FN ERT: ERG-5003-001, ERG-5003-002, ERG-5003-003, ERG-5003-004, ERG-5003-005, ERG-5003-006, ERG-5003-007, ERG-5003-008, ERG-5003-009
100G DLS ERT: ERG-5006-001, ERG-5006-002, ERG-5006-003, ERG-5006-004, ERG-5006-005, ERG-5006-006, ERG-5006-007, ERG-5006-008, ERG-5006-009
Copyright
© 2010 - 2012 Itron, Inc. All rights reserved.
Confidentiality Notice
The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is
used only for the purposes described herein. Any third party given access to this information is similarly bound in writing.
Trademark Notice
Itron is a registered trademark of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Applicable Patents
U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700
Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118
Compliance Statement
This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to
the following two conditions:
 This device may not cause harmful interference.
 This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
 Reorient or relocate the receiving antenna.
 Increase the separation between the equipment and receiver.
 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
 Consult the dealer or an experienced radio or TV technician for help.
Compliance Statement
This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules.
Operation is subject to the following two conditions:
 (1) this device may not cause interference, and
 (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Déclaration de conformité
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
 (1) l'appareil ne doit pas produire de brouillage, et
 (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, any 100G series gas ERT is considered an operating transmitter
and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to
operate the equipment.
Meter Installation/Removal
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
Warning Follow these procedures to avoid injury to yourself or others:




The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), crush, expose to water, or
incinerate the lithium battery. Fire, explosion, and severe burn hazard.
Keep the lithium battery away from children.
Replace the lithium battery only with batteries meeting Itron specifications. Any other battery may
cause a fire or explosion.
Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by
others might void any maintenance contract with your company. Unauthorized service personnel might also
be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.
Warning To prevent ignition of flammable or combustible atmospheres, disconnect power
before servicing.
Warning Substitution of components may impair intrinsic safety.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
ii
Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
 Internet: www.itron.com
 E-mail: support@itron.com
 Phone: 1 877 487 6602
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
iii
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
iv
Contents
Before You Begin ........................................................................................................ vii
Document Conventions ..................................................................................................................... vii
Document Purpose ............................................................................................................................ vii
Chapter 1 About the 100G DLS Gas ERT Module ...................................................... 1
Transmission Modes ...........................................................................................................................1
100G DLS Gas ERT Module Security .................................................................................................2
Enabling 100G DLS Gas ERT Module Security .................................................................................2
100G Series Gas ERT Specifications .................................................................................................2
Related Documents ............................................................................................................................3
100G Series Gas ERT Meter Compatibility List ..................................................................................3
Installation Prerequisites ...................................................................................................................12
Installation Overview .........................................................................................................................13
Chapter 2 Elster American Meter Installation .......................................................... 14
Removing the Meter Index ................................................................................................................14
Assembling the ERT Module and Index ............................................................................................15
Programming the 100G DLS Gas ERT Module Assembly ...............................................................18
Attaching the 100G DLS Gas ERT Module Assembly to the Meter ..................................................19
Chapter 3 Sensus (Invensys, Equimeter, Rockwell) Meter Installation ................. 22
Removing the Meter Index ................................................................................................................22
Assembling the ERT Module and Index ............................................................................................23
Programming the 100G DLS Gas ERT Module Assembly ...............................................................26
Attaching the 100G DLS gas ERT module Assembly to the Sensus Meter .....................................27
Chapter 4 Itron (Sprague) Meter Installation ............................................................ 29
Removing the Meter Index ................................................................................................................29
Assembling the ERT Module and Index ............................................................................................30
Programming the 100G DLS Gas ERT Module Assembly ...............................................................32
Attaching the 100G DLS Gas ERT Module Assembly to the Meter .................................................33
Attaching the 100G DLS Gas ERT Module Assembly to Flat-faced Sprague Meters ......................37
Securing Brass Meter Tags to Flat-faced Meters..............................................................................38
Attaching the 100G DLS Gas ERT Assembly on Sprague 175RM Meters ......................................40
Removing the Meter Index ................................................................................................................40
Assembling the ERT Module and Index ...........................................................................................41
Programming the 100G DLS Gas ERT Module Assembly ...............................................................44
Attaching the 100G DLS Gas ERT Module to the Sprague 175RM Meter .......................................45
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
Contents
Chapter 5 National (Lancaster) Meter Installation ................................................... 48
Removing the Meter Index ................................................................................................................48
Assembling the ERT Module and Index ............................................................................................49
Programming the 100G DLS Gas ERT Module Assembly ...............................................................53
Attaching the 100G DLS Gas ERT Module Assembly to the Meter ..................................................54
Chapter 6 Elster American and Itron (Actaris) Commercial Meter Installation ..... 57
Removing the Index or Index Assembly from the Meter ...................................................................57
Programming the 100G DLS Gas ERT Module ................................................................................60
Attaching the 100G DLS Gas ERT Module to the Commercial Meter ..............................................61
Installing the Commercial 100G DLS Gas ERT Module on an Itron (Actaris) Commercial Meter ....65
Programming the 100G DLS Commercial Gas ERT .........................................................................68
Attaching the 100G DLS Gas ERT Module to the Commercial Meter ..............................................69
Chapter 7 Sensus (Rockwell) Commercial Meter Installation................................. 74
Removing the Index or Index Assembly from the Meter ...................................................................74
Programming the 100G DLS gas ERT module .................................................................................76
Attaching the 100G DLS Gas ERT Module to a Sensus/Rockwell Commercial Diaphram Meter ....77
Mounting a 100G DLS Gas ERT Module on a Rockwell 750 meter with an Aluminum Box
Direct Reading (VDR) ........................................................................................................................80
Attaching the 100G DLS Gas ERT Module to a Sensus/Rockwell Commercial Diaphram Meter ....81
Chapter 8 GE Oil & Gas Dresser Commercial Rotary Meter Installation ............... 84
Installation Prerequisites ...................................................................................................................84
Installation Examples ........................................................................................................................85
Programming the 100G DLS Assembly ............................................................................................86
B3, LMMA, and S3A CTR/TC Dresser Series Register Settings and Direct Drive Programming
Information.........................................................................................................................................88
B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* ..............89
Installing the Residential 100G DLS ERT Module Assembly to the Dresser Rotary Meter ..............90
Installing the Commercial Gas ERT on a Dresser Rotary Meter with an Instrument Drive ..............91
Programming the 100G DLS Commercial Gas ERT Module Assembly ...........................................92
B3, LMMA, and S3A CD/TD Dresser ROOTS® Series Meter Drive Rates ......................................94
Completed Installation Examples .....................................................................................................98
Index ............................................................................................................................. 99
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
vi
Before You Begin
Before You Begin
Document Conventions
The following documentation conventions are used in this installation guide:
Caution A Caution warns the installer that failure to follow the information in the note could result in
loss of data. Be sure to carefully read a Caution note and follow the advice or instructions.
Warning A Warning alerts the installer about potential physical harm to the installer or hardware. It
is critical that you pay strict attention to Warning notes, read the information carefully, and follow the
advice or instructions.
Tip A Tip provides the installer with extra hints or suggestions to make a task easier to perform or a
concept easier to understand.
Note A Note supplies generic information to the installer. The installer can ignore the information
and continue a task without suffering any adverse consequences.
Document Purpose
This installation guide provides step-by-step instructions for installing the 100G series gas ERT module on a
wide variety of meters. This installation guide may refer to the 100G series as the 100G DLS gas ERT module
based on form or meter type. Mechanical installation procedures are identical for all modules. 100G series gas
ERT module compatible meters are listed in the Meter Compatibility List.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
vii
Before You Begin
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
viii
CHAPTER 1
About the 100G DLS Gas ERT Module
Itron 100G DLS gas ERT modules are radio-frequency (RF) devices designed to transmit meter data to an RF
meter reading device within transmission distance of the ERT module. The 100G gas ERT was designed with
a higher output power than earlier Itron gas ERT modules to achieve an increased RF transmission distance.
The 100G series gas ERT modules have greater output power to meet Itron mobile and fixed network
requirements. The first 100G gas ERT module offered high transmit power capability which increased
operational efficiency and reduced infrastructure costs. The 100G Datalogging gas ERT module was enhanced
to offer higher transmit power with data logging capability (time-stamped hourly interval data) for both
mobile and fixed network applications. Itron's 100G Datalogging Fixed Network (DLN) gas ERT module
added improved network performance through a higher transmit power, accomplished using increased antenna
efficiency and more robust optimized messaging structures. Itron's 100G DLS gas ERT module continues a
legacy of increased efficiency in messaging and adds network security.
Transmission Modes
The 100G DLS gas ERT module can be set to transmit in Fixed Network, Mobile and Handheld, or Hard to
Read Mobile and Handheld Mode.

Fixed Network Mode. The 100G DLS transmits a high-powered network interval message (NIM) RF
message every five minutes. Output power in this mode is 500 milliwatts or +27 dBm. Interspersed in the
high power NIM, the 100G DLS transmits a medium power RF message at 10 milliwatts or +10 dBm
every 60 seconds; expected battery life is 20 years.

Mobile High Power Mode. The 100G DLS transmits a high-powered RF message every 60 seconds.
Output power in this mode is 250 milliwatts or +24dbm; expected battery life is 20 years.

Mobile and Handheld Mode. The 100G DLS transmits a medium-powered RF message every 15
seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years.

(Optional) Hard to Read Mobile and Handheld Mode. The 100G DLS transmits a high-powered RF
message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life
decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for
exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements).
An FCC license is not required to read 100G series gas ERT modules.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
About the 100G DLS Gas ERT Module
100G DLS Gas ERT Module Security
The 100G DLS is a component of a ChoiceConnect system. ChoiceConnect system security applies to the RF
communications between the handheld computer, Mobile Collector, or Fixed Network system and the ERT
module. There are two fundamental security processes used in the ChoiceConnect system to ensure
confidentiality and validity of the system communications.

Authentication. Authentication is the process of confirming that an artifact is genuine or valid.
Authentication in the 100G DLS is the process of verifying a request is from a valid source and in its
original form.

Encryption. Encryption is the process of transforming information to make it unreadable to anyone who
does not have a valid security key. There are two types of encryption, symmetric and asymmetric.
Symmetric encryption uses a shared key to decrypt or encrypt information. Asymmetric encryption uses a
private key to encrypt and a public key to decrypt.
As a component of the Itron ChoiceConnect solution, the 100G DLS supports the security model found in the
ChoiceConnect solution for both reading and programming. If the 100G DLS modules are shipped without
ChoiceConnect security enabled, the utility can, at a later date, inject security key sets into the 100G DLS
ERT modules.
Enabling 100G DLS Gas ERT Module Security
When 100G DLS ERT modules ship from an Itron factory, each module contains a Utility Factory key. The
presence of this Utility Factory key does not enable security. The installer must enable security by injecting
keys into the 100G DLS using an Itron programming device and programming commands. Initial key
exchange commands are secured using the Utility Factory key. For more information, see the Field
Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) programming guide.
100G Series Gas ERT Specifications
Functional Specifications
Power Source
100G
100G Datalogging
100G Datalogging FN
100G DLS
Tamper Detection
Description
Two "A" cell lithium batteries
One "A" cell lithium battery
Tilt tamper and magnetic tamper
FCC Compliance
Part 15 certified
Industry Canada Compliance
RSS-210 certified
Intrinsically Safe per
UL Class I, Division 1, Groups C and D
Product Identification
Numeric and bar coded ERT type and serial number
Construction Materials
Gray polycarbonate housing and back plate with encapsulated electronics
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
About the 100G DLS Gas ERT Module
Operational Specifications
Description
Operating Temperatures
-40° to 158° F (-40° to +70° C)
Operating Humidity
5 to 95 percent relative humidity
Program Frequency
908 MHz
Transmit Frequency
Spread spectrum 908 to 924 MHz ISM band
Data Integrity
Verified in every data message
Related Documents
Document Title
Document Part Number
Gas Module Meter Compatibility List
PUB-0117-002
Gas Module Ordering Guide
PUB-0117-001
100G DLS Gas ERT Specification Sheet
Publication 100941SP-XX
100G DLS Gas ERT Installation Guide, Remote Mount
TDC-0824-XXX
Field Deployment Manager Endpoint Tools Mobile Application Guide
TDC-0934-XXX
Field Deployment Manager Field Representative's Guide
TDC-0936-XXX
100W and 100G ERT Tamper Reference Guide
TDC-1028-XXX
Note The last three digits of the user and installation guides represent the document's revision level. The
revision level is subject to change without notice.
100G Series Gas ERT Module Meter Compatibility List
The following table lists meter types compatible with 100G series gas ERT modules. Due to continuous
research and product improvements and enhancements, Itron reserves the right to change product or system
specifications without notice.
Elster American (Canadian)
Meter Model
Meter Notes
100G Module Type
W75AL
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AC-175
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AL-175
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
ALC-175
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
Gas Module Notes
About the 100G DLS Gas ERT Module
Meter Model
Meter Notes
100G Module Type
AT-175
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AT-210
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AL-225
Aluminum case, Canada only
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
5B-225
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
Must cut 1/16" off the end of the
module wriggler drive post which will
make the module incompatible with
other 2-ft. drive meters.
10 Metric B
Originally manufactured by Metric
Metal Works
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
ERT module with 2.5' cable
AC-250
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AL-250
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AM-250
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AR-250
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AT-250
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AL-350
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AL-425
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AC-630
Aluminum case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
Gas Module Notes
About the 100G DLS Gas ERT Module
Meter Model
Meter Notes
100G Module Type
AL800
Top mount index
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
AL1000
Top mount index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
AL1400
Top mount index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
AL2300
Top mount index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
AL3000
Top mount index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
AL5000
35B
Iron case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
60B
Iron case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
80B
Iron case, must have front-reading
index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
250B
Iron case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
500B
Iron case
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
RPM Rotary
CTR, TC (No pulser, no instrument
drive) Use Elster American kit
numbers 93179K002, 003, 004, or
005 to modify the meter with an
adapter to attach the residential
module.
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-003
ERG-5002-003
ERG-5003-003
ERG-5006-003
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
Gas Module Notes
About the 100G DLS Gas ERT Module
GE Oil & Gas/Dresser Meters (ROOTS)
Meter Model
Meter Notes
100G Module Type
Series B3
8C—56M CTR
8C—16M TC
(No pulser,
No instrument drive)
To attach an Elster American AMR
adapter kit, install Dresser AMR
adapter kit, P/N 059599-000.
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
Series A
(LMMA)
1.5M—5M
CTR (No pulser, No
instrument drive)
To attach an Elster American AMR
adapter kit, install Dresser AMR
adapter kit, P/N 058530-610.
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
Series Z
5C/8C15
To attach an Elster American Dresser 100G
AMR adapter kit, install Dresser
100G Datalogging
AMR adapter kit, P/N 059224-847
100G Datalogging FN
100G DLS
ERG-5000-001
ERG-5002-001
ERG-5003-001
ERG-5006-001
Instrument drive
B3: CTR
TC, 8C—11M
LMMA: CTR
TC: 1.5M—11M
Instrument platform with mechanical
drive.
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
Series A
(LMMA)
7M—16M
CTR (No pulser, No
instrument drive)
Series A
(LMMA)
1.5M—5M
TC (No pulser, No
instrument drive)
To attach an Elster American AMR
adapter kit, install Dresser AMR
adapter kit, P/N 058531-610.
To attach an Elster American AMR
adapter kit, install Dresser AMR
adapter kit, P/N 058224-610.
Gas Module Notes
Itron (Actaris, Schlumberger, Sprague)
Meter Model
Meter Notes
100G Module Type
Itron Part
Number
175
2-hole index cover
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
3-hole index cover
175 Combination
3-hole index cover
integrated regulator
2-hole index cover
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
175RM
Flat-face meter
regulator on back of meter
100G Datalogging FN
100G DLS
ERG-5003-009
ERG-5006-009
175WC
3-hole index cover
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-006
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
Gas Module Notes
Requires index boxes with 3 mounting
holes
About the 100G DLS Gas ERT Module
Meter Model
Meter Notes
100G Module Type
210
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
240
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
240
Flat-face meter 1-hole index cover
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
240
2-hole index cover
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
240 Combination
Integrated regulator
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
250
Gas Module Notes
Module requires Itron 1A Adapter Kit,
P/N CFG-0015-001.
250WC
Integrated regulator
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
METRIS 250
Slant-face
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
A longer mounting screw may be
required when retrofitting to some
vintage METRIS meters. Longer
mounting screw is Itron P/N 010626.
1A
Flat-face meter includes 3-dial, 2 cf
indexes.
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
Installation requires Itron 1A Adapter
Kit, P/N CFG-0015-001.
305 Combination
Integrated regulator
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
400
Slant-face meter
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
400A
Slant-face meter
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-005
ERG-5002-005
ERG-5003-005
ERG-5006-005
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
About the 100G DLS Gas ERT Module
Meter Model
Meter Notes
100G Module Type
Gas Module Notes
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
675A
Top-mount index
800A
Top-mount index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
Requires Itron (Actaris) adapter P/N
8005901-001. Purchase from Itron.
1000A
Top-mount index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
Requires Itron (Actaris) adapter P/N
8005901-001. Purchase from Itron.
Meter Model
Meter Notes
100G Module Type
Gas Module Notes
175
National meter indexes with bow-tie
shaped wrigglers cannot be used.
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-006
ERG-5002-006
ERG-5003-006
ERG-5006-006
U175
UL175
National meter indexes with bow-tie
shaped wrigglers cannot be used.
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-006
ERG-5002-006
ERG-5003-006
ERG-5006-006
Actaris/Schlumberger/Sprague direct
read (odometer) indexes cannot be
used.
250
National meter indexes with bow-tie
shaped wrigglers cannot be used.
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-006
ERG-5002-006
ERG-5003-006
ERG-5006-006
Actaris/Schlumberger/Sprague direct
read (odometer) indexes cannot be
used.
Meter Model
Meter Notes
100G Module Type
Gas Module Notes
Instrument drive
RM series. Standard index drive and no 100G
instrument
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-007
ERG-5002-007
ERG-5003-007
ERG-5006-007
Gas Module Notes
Requires Itron (Actaris) adapter P/N
8005901-001. Purchase from Itron.
National (Lancaster)
Actaris/Schlumberger/Sprague direct
read (odometer) indexes cannot be
used.
Romet
Sensus (Invensys/Equimeter/Rockwell/EMCO)
Meter Model
Meter Notes
100G Module Type
RT-100
18-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
Iron Part
Number
ERG-5000-004
ERG-5002-004
ERG-5003-004
ERG-5006-004
S-110
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
T-110
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
24- and 30-tooth gears are not
compatible.
About the 100G DLS Gas ERT Module
Meter Model
Meter Notes
100G Module Type
S-120
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
T-120
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
R-175
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
S-175
18-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-004
ERG-5002-004
ERG-5003-004
ERG-5006-004
24- and 30-tooth gears are not
compatible.
S-190
18-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-004
ERG-5002-004
ERG-5003-004
ERG-5006-004
24- and 30-tooth gears are not
compatible.
R-200
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
RT-200
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
S-200
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
RC-225
11-tooth (Canadian only)
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
RT-225
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
RC-230
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
RCM-230
(RC-230 Metric)
16-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-003
ERG-5002-003
ERG-5003-003
ERG-5006-003
24- and 30-tooth gears are not
compatible.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
Gas Module Notes
About the 100G DLS Gas ERT Module
Meter Model
Meter Notes
100G Module Type
Gas Module Notes
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
RT-230
11-tooth
250
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
R-275
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
MR-8
(R-275 Metric)
16-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-003
ERG-5002-003
ERG-5003-003
ERG-5006-003
24- and 30-tooth gears are not
compatible.
RT-275
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
S-275
11-tooth (side connections)
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
MR-5
(S-275 Metric)
16-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-003
ERG-5002-003
ERG-5003-003
ERG-5006-003
24- and 30-tooth gears are not
compatible.
310
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
R-315
11-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-002
ERG-5002-002
ERG-5003-002
ERG-5006-002
24- and 30-tooth gears are not
compatible.
MR-9
(R-315 Metric)
16-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-003
ERG-5002-003
ERG-5003-003
ERG-5006-003
24- and 30-tooth gears are not
compatible.
RT-360
18-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-004
ERG-5002-004
ERG-5003-004
ERG-5006-004
415
18-tooth. Older meters may have gas
module to meter mounting hole
variations that can make them
incompatible.
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-004
ERG-5002-004
ERG-5003-004
ERG-5006-004
MR-12
(415 Metric)
16-tooth
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-003
ERG-5002-003
ERG-5003-003
ERG-5006-003
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
24- and 30-tooth gears are not
compatible.
10
About the 100G DLS Gas ERT Module
Meter Model
Meter Notes
100G Module Type
750
Vertical index only
100G
100G Datalogging
100G Datalogging FN
100G DLS
Itron Part
Number
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
1000
Vertical index only
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
1600
Vertical index only
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
3000
Vertical index only
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
5000
Vertical index only
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
10000
Vertical index only
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
750, 1000, 1600,
3000, 5000, 10000
Aluminum box direct reading (VDR)
index
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
EMCO
#2-1/2
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
EMCO
#3
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
EMCO
#4
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
EMCO
#4-1/2
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
EMCO
#5
100G
100G Datalogging
100G Datalogging FN
100G DLS
ERG-5000-008
ERG-5002-008
ERG-5003-008
ERG-5006-008
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
Gas Module Notes
11
About the 100G DLS Gas ERT Module
Installation Prerequisites
Prior to installation, verify you have the following items:

100G gas ERT module designed for your specific brand of residential or commercial gas meters (ERTs
include new tamper seals).

A compatible meter (see the 100G Series Gas ERT Module Meter Compatibility List).

A compatible index. Itron 100G DLS gas ERT modules are compatible with standard dial and direct-read
(odometer) indexes. Exceptions are noted on the 100G Series Gas ERT Module Meter Compatibility List.

Installation tools (provided by installer or customer).

Small and medium flat-blade or Phillips screwdrivers.

Side-cutting plier/wire snips.

Small putty knife, residential meters.

Meter seals, wire seal, and seal press.

11/32-inch nut driver or other blunt tool.

Itron programming device:
FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or
FC300 with SRead with Field Deployment Manager (FDM) software version 1.1 or higher
or
900 MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager
(FDM) software version 1.1 or higher and a customer-supplied laptop

Replacement screws:
Replacement Screws
Meter
To mount the 100G DLS
gas ERT module on the
meter:
Elster American
1/4 - 20 x 5/8" slotted, Fillister
head
8 - 32 x 3/16" slotted, Fillister
head
Sensus/Rockwell
10 - 24 x 5/8" slotted, Fillister
head
6 - 32 x 5/8" slotted, Fillister head
10 - 24 x 5/8" slotted, Fillister
head
Sprague/Schlumberger 10 - 24 x 1/2-inch, slotted
175 RM
Fillister head
Itron Part
Number
Itron/Sprague
National/Lancaster
10 - 24 x 3/4" Phillips, flathead, stainless steel
SCR-0175-002
SCR-0014-004
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
To mount the index on the Itron Part
100G DLS gas ERT module Number
housing:
10 - 24 x 1/4" slotted, Fillister
head
10 - 24 x 3/8" thread-forming,
Phillips pan-head to mount
indexes with legs
6 - 19 x 3/8" thread-forming,
Phillips, Fillister head to mount
indexes with screw holes
SCR-0017-001
SCR-0037-001
12
About the 100G DLS Gas ERT Module
Replacement Screws
Commercial Meter
To mount the 100G DLS
commercial ERT on the
meter:
Itron Part
Number
Elster American
2A x 3.35" length, slotted
round-head drilled to accept
utility-approved wire seals
SCR-0062-001
Sensus/Rockwell
2A x 3.63" length, slotted
round-head drilled to accept
utility-approved wire seals
SCR-0062-002
Sensus/Rockwell
For Aluminum Box Direct
Reading (VDR) index only
To mount the index (and
Itron Part
index assembly, if
Number
applicable) on the 100G
DLS commercial ERT
housing:
12 - 24 x 1/2" slotted, Fillister
head machine screws, drilled to
accept utility-approved wire seals
2A x 2.94" length, slotted round- SCR-0062-003
head
Installation Overview
Installing the 100G DLS gas ERT module on a meter involves four tasks:
1. Removing the index cover and index from the meter.
2. Assembling the 100G DLS and index.
3. Programming the 100G DLS assembly.
4. Attaching the 100G DLS to the meter.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
13
CHAPTER 2
Elster American Meter Installation
This chapter provides the instructions to install the 100G DLS gas ERT module on an Elster American Meter.
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover
materials. Do not leave materials on customer premises.
Removing the Meter Index
Begin the ERT module installation by removing the index cover and index from the meter.
To remove the index from the meter
1. Remove the four index cover screws and the index cover from the Elster American meter. Alternate screw
removal following the numbered pattern in the photo.
2. Examine the mounting screws. If they are 5/8-inch long and not corroded, keep them to re-attach the 100G
DLS assembly. If the screws are not the correct length or if the screws are corroded, discard.
Note You may use the removed index cover as a temporary storage container for screws. Properly
dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not
leave materials on customer premises.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
14
Elster American Meter Installation
3. Unscrew one index mounting screw completely. Hold one hand under the index to catch the screw. While
removing the other mounting screw, pull the index away from the meter to keep the index backplate
against the back of the screw. Remove the screw completely after the index is free of the meter.
Set the index aside where it will not be damaged or fill with dirt, rain or snow. The index will be mounted
to the ERT later in this procedure.
4. Verify the index mounting screws are 3/16-inch long and not corroded. If the screws are the correct length
and not corroded, retain for later use. If you discarded the original screws, use the correct replacement
screws (see Installation Prerequisites.)
5. Remove the old gasket, gasket residue and dirt from the meter (if applicable). The meter face must be free
of gasket residue before you install the 100G DLS gas ERT module.
Assembling the ERT Module and Index
Continue ERT module installation by assembling the ERT module and index.
To assemble the 100G DLS gas ERT module and index
1. Separate the ERT module housing from the cover by pulling the cover straight out from the housing.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
15
Elster American Meter Installation
2. Set the ERT module clear cover aside where it will not be damaged or fill with rain, dirt, or snow. You
will use the cover later in this installation procedure.
Note Elster American Meter indexes are available in different models:
Index wrigglers on one-foot meters with drive slots Index meters on two-foot meters with drive
posts
Index with mounting screw holes
Index with mounting slots
If your index has mounting screw slots, skip steps 3 and 4. If your index has mounting screw holes,
perform steps 3 and 4, and skip steps 5 and 6.
3. Using the original index mounting screw or a replacement screw, if necessary, place one 8 - 32 3/16-inch
screw into the index's right-hand mounting screw hole.
4. Attach the screw to the ERT housing's right-index mounting post just enough to hold the screw and the
right end of the index in place.
5. Screw one 8 - 32 x 3/16-inch screw into the right index mounting post one or two turns. Do not tighten the
screw.
6. Place the right index mounting screw slot under the screw head. Do not tighten the screw.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
16
Elster American Meter Installation
7. Slide the index drive post into the ERT wriggler. Verify positive engagement.
Caution If the index wriggler has a drive slot, place the ERT wriggler's drive post into the index drive
slot. Failure to mate the ERT module wriggler with the index drive post (or slot) can cause binding and
lead to poor registration or meter failure.
8. Install and tighten the left index mounting screw (for indexes with either mounting screw slots or holes).
Tighten the right index mounting screw. Install and tighten index mounting screws evenly.
9. Slide the ERT cover over the index and housing. Verify the cover is installed correctly. The ERT label
should be clearly visible and easily read.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
17
Elster American Meter Installation
Programming the 100G DLS Gas ERT Module Assembly
Program the 100G DLS using:

An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or

A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher
or

A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
See the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete
programming information.
FC200SR
FC300 with SRead
900MHz Belt Clip Radio
Caution You must program the 100G DLS gas ERT module before use.
The ERT is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower
dial on the index. Elster American meter index drive rates are either 1-cubic foot, 2-cubic feet or 0.05 cubic
meters (not shown below).
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
18
Elster American Meter Installation
To program the 100G DLS gas ERT module

Program the meter drive rate into the 100G DLS gas ERT module using the endpoint programming
device.

For all programming and Check Endpoint operations, hold the handheld programmer as close to
vertical as possible. For best success, keep the handheld programmer within 6 feet of the target ERT.

Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode,
Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.
Programming parameters are based on the configuration file loaded into the ERT module programming
device. During programming, the 100G DLS gas ERT module is set to the nearest 100 cubic feet; the last two
digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT assembly will
read to the nearest cubic foot.
Attaching the 100G DLS Gas ERT Module Assembly to the
Meter
After programming the 100G DLS gas ERT module, attach the ERT assembly to the Elster American Meter.
Warning For 5B Meters only: If you are installing the 100G DLS on a 5B-225 aluminum
meter, cut 1/16-inch off each ERT wriggler post to prevent the wriggler from rubbing on the
face of the nut holding the meter drive dog in place. Trimming the drive post may make the
module incompatible with other 2-ft. drive meters.
To attach the 100G DLS gas ERT module to the meter
1. Align the ERT wriggler to connect with the drive post (or slot) of the meter.

For one-foot meters: Align the ERT assembly wriggler perpendicular to the meter drive post.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
19
Elster American Meter Installation

For two-foot meters: Align the ERT assembly wriggler perpendicular to the meter drive slot. The pin
on the ERT wriggler may be installed inside or outside the meter drive slot. For easy assembly, Itron
recommends installing the pin on the 100G DLS wriggler outside the meter drive slot.
Warning Failure to correctly align the meter drive post and ERT module drive slot can cause binding
and lead to poor registration or meter failure. If there is a gap between the ERT module gasket and the
meter, it may be the drive slot of the ERT module assembly's wriggler is not correctly aligned with the
meter drive slot. Remove the 100G DLS assembly and repeat the alignment procedure. You must engage
ERT module wriggler in the meter drive dog.
2. Carefully align the ERT's four screw holes with the holes on the meter. Attach using the original mounting
screws if they are the correct size and are not corroded (1/4 - 20 x 5/8-inch screws.) If you discarded the
original screws, use the correct replacement screws (see Installation Prerequisites). Tighten in an
alternating, diagonal pattern as shown in the photo:

Insert first screw and tighten 1/4 to 1/2 turn after the screw contacts the meter connection.

Insert the second screw and tighten 1/4 to 1/2 turn after contact with the meter connection.

Insert the third screw and tighten 1/4 to 1/2 turn after contact with the meter connection.

Insert the last screw and tighten 1/4 to 1/2 turn after contact with the meter connection.
Return to the first screw and tighten. Continue with the second, third and last screw until all screws are
tight. Use equal screw tension to tighten each screw.
Important Meter manufacturers: torque the mounting screws 15 to 20 inch-pounds.
3. Place new tamper seals over the two screws with tamper seal mounts. Press tamper seals into place using
an 11/32-inch nut driver or similar blunt tool.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
20
Elster American Meter Installation
4. Complete necessary paperwork and verify all excess materials are removed from the customer premises.
100G DLS gas ERT module installation on the Elster American meter is complete.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
21
CHAPTER 3
Sensus (Invensys, Equimeter, Rockwell) Meter Installation
This chapter provides the instructions to install the 100G DLS Gas ERT Module on a Sensus/Rockwell Meter.
These instructions apply to 11-tooth, 16-tooth, and 18-tooth Sensus 100G DLSs.
Note Sensus meters are also known as Invensys, Equimeter, and Rockwell. For these instructions,
all meter types are referred to as Sensus meters.
100G DLS gas ERT module
Sensus 11-tooth
Sensus 16-tooth
Sensus 18-tooth
Removing the Meter Index
Begin the ERT module installation by removing the index cover and index from the meter.
To remove the index from the meter
1. Remove the four index cover screws and the index cover from the Sensus meter. Alternate screw removal
following the numbered pattern as shown in the following illustration.
2. Examine the mounting screws. If they are 5/8-inch long and not corroded, keep them to attach the 100G
DLS gas ERT module assembly. If the screws are not the correct length or if the screws are corroded,
discard.
Note You may use the removed index cover as a temporary storage container for screws. Properly
dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not
leave materials on the customer premises.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
22
Sensus (Invensys, Equimeter, Rockwell) Meter Installation
3. Remove one index mounting screw completely. Hold one hand under the index to catch the screw. While
removing the other mounting screw, pull the index away from the meter to keep the index backplate
against the back of the screw. Remove the screw completely after the index is free of the meter.
4. Set the index aside where it will not be damaged or fill with dirt, rain, or snow. You will mount the index
in the ERT later in this procedure. Verify the index mounting screws are 5/8-inch long and not corroded.
If the screws are the correct length and not corroded, retain for later use. If you discard the original
screws, use the correct replacement screws (see Installation Prerequisites on page 12.)
5. Remove the old gasket, gasket residue, and dirt from the meter (if applicable). The meter face must be free
of gasket residue or dirt before you install the 100G DLS.
Assembling the ERT Module and Index
Continue ERT module installation by assembling the ERT module and index.
To assemble the 100G DLS gas ERT module and index
1. Separate the ERT module housing from the clear cover by pulling the cover straight out from the housing.
Set the ERT cover aside where it will not be damaged or fill with rain, dirt, or snow. You will replace the
cover later in this installation procedure.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
23
Sensus (Invensys, Equimeter, Rockwell) Meter Installation
2. Place the index drive gear (1) in the housing wriggler gear cup (2) of the ERT. The example shows an 11tooth drive gear. Your index may be a 16- or 18-tooth gear. Use the appropriate 100G DLS gas ERT
module for your specific meter. See the Meter Compatibility List on page 3 for more information.
3. After the drive gear is aligned with the wriggler gear, the mounting holes will line up.
Warning Indexes have varying drive mechanism styles. Failure to align the ERT wriggler with the index
drive post can cause binding and lead to poor registration or meter failure. To verify proper engagement of
the index to the ERT housing, spin the wriggler one clockwise rotation, then one-counterclockwise
rotation. Do not spin the wriggler more than one complete rotation. The wriggler should spin freely, with
little or no resistance.
4. Using the original index mounting screw or a replacement screw (if necessary), place one 6 - 32 x 5/8-inch
screw into the index right mounting screw hole.
5. Attach the screw to the ERT housing right-index mounting post just enough to hold the screw and the
right end of the index in place.
6. Install and tighten the left index mounting screw.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
24
Sensus (Invensys, Equimeter, Rockwell) Meter Installation
7. Tighten the right index mounting screw completely. Install and tighten both index mounting screws
evenly.
8. Slide the ERT cover over the index and housing. Verify the cover is installed correctly. The ERT label
should be clearly visible and easily read.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
25
Sensus (Invensys, Equimeter, Rockwell) Meter Installation
Programming the 100G DLS Gas ERT Module Assembly
Program the 100G DLS using:

An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or

A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher
or

A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
See the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete
programming information.
FC200SR
FC300 with SRead
900MHz Belt Clip Radio
Caution You must program the 100G DLS gas ERT module before use.
The ERT is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower
dial on the index. Elster American meter index drive rates are either 1-cubic foot, 2-cubic feet or 0.05 cubic
meters (not shown below).
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
26
Sensus (Invensys, Equimeter, Rockwell) Meter Installation
To program the 100G DLS gas ERT module

Program the meter drive rate into the 100G DLS gas ERT module using the endpoint programming
device.

For all programming and Check Endpoint operations, hold the handheld programmer as close to
vertical as possible. For best success, keep the handheld programmer within 6 feet of the target ERT.

Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode,
Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.
Programming parameters are based on the configuration file loaded into the ERT module programming
device. During programming, the 100G DLS gas ERT module is set to the nearest 100 cubic feet; the last two
digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT assembly will
read to the nearest cubic foot.
Attaching the 100G DLS gas ERT module Assembly to the
Sensus Meter
After 100G DLS gas ERT module programming is complete, attach the ERT assembly to the Sensus meter.
To attach the 100G DLS gas ERT module to the meter
1. Place the ERT assembly against the front of the meter at angle.
Warning Failure to correctly align the meter drive post and ERT module drive slot can cause binding
and lead to poor registration or meter failure. If there is a gap between the ERT module gasket and the
meter, it may be the drive slot of the ERT module assembly's wriggler is not correctly aligned with the
meter drive slot. Remove the 100G DLS assembly and repeat the alignment procedure. You must engage
ERT module wriggler in the meter drive dog.
2. Install and tighten the ERT-to-meter mounting screws in an alternating pattern. Use the original mounting
screws if they were the correct size and not corroded. If you discarded the original screws, use the correct
replacement screws (see Installation Prerequisites on page 12).

Align the top right mounting screw hole on the meter with the top right screw hole on the ERT.

Insert the top right cover mounting screw and tighten the screw enough to hold the ERT assembly in
place. Do not completely tighten the screw.

Rotate the ERT assembly counterclockwise until the remaining three ERT screw holes line up with the
holes in the meter.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
27
Sensus (Invensys, Equimeter, Rockwell) Meter Installation
3. Install the remaining three mounting screws and tighten in the pattern shown in the following illustration.
Tighten each mounting screw evenly.
a. Insert lower left mounting screw (2) and tighten to snug position.
b. Tighten upper right mounting screw (1,3) to snug position.
c. Insert upper left mounting screw (4) and tighten to snug position.
d. Insert lower right mounting screw (5) and tighten to snug position.
Important Meter manufacturers: torque the mounting screws 15 to 20 inch-pounds.
4. Place a new tamper seal over the two screws with tamper seal cups. Press the new tamper seals into place
using an 11/32-inch nut driver (or similar blunt tool).
5. Complete any necessary paperwork and properly dispose excess installation materials and scrap from the
customer premises.
100G DLS installation on the Sensus meter is complete.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
28
CHAPTER 4
Itron (Sprague) Meter Installation
This chapter provides the instructions to install the 100G DLS Gas ERT Module on an Itron (Sprague) meter.
Note Itron (Sprague) meters are also known as Actaris and Schlumberger
meters. For these instructions, all meters will be referred to as Itron or Sprague
meters.
Removing the Meter Index
Begin the ERT module installation by removing the index cover and index from the meter.
To remove the index from the meter
1. Remove the index cover screws and the index cover from the Itron (Sprague) meter. Examine the
mounting screws. If they are 5/8-inch long and not corroded, keep them to re-attach the 100G DLS
assembly. If the screws are not the correct length or if the screws are corroded, discard.
Note Use the removed index cover as a temporary storage container for the screws. Properly dispose all
unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave
materials on customer premises.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
29
Itron (Sprague) Meter Installation
2. Loosen the index mounting screws 1/2 to one turn. Slide the index to the left and off the mounting screws.
Remove the index from the meter.
3. Set the index aside where it will not be damaged or fill with dirt, rain, or snow. You will mount the index
in the ERT later in this procedure.
4. Verify the index mounting screws are 1/4-inch long and not corroded. If the screws are the correct length
and not corroded, retain for later use. If you discard the original screws, use the correct replacement
screws (see Installation Prerequisites on page 12).
5. Remove the old gasket, gasket residue, and dirt from the meter (if applicable). The meter face must be free
of gasket residue or dirt before you install the 100G DLS.
Assembling the ERT Module and Index
Continue ERT module installation by assembling the ERT module and index.
To assemble the 100G DLS gas ERT module and index
1. Separate the 100G DLS housing from the cover by pulling the cover straight out from the housing. Set the
ERT cover aside where it will not be damaged or fill with rain, dirt or snow. You will use the cover later
in this installation procedure.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
30
Itron (Sprague) Meter Installation
2. Insert the 10 - 24 x 1/4-inch screws into the index mounting posts two turns. Do not tighten the screws.
3. Align the index wriggler (1) with the ERT drive post (2). Carefully slide the index onto the mounting
screws.
4. Verify the 100G DLS housing drive post makes positive engagement with the index wriggler.
Warning Indexes have varying drive mechanism styles. Failure to align the ERT wriggler with the index
drive post can cause binding and lead to poor registration or meter failure. To verify proper engagement of
the index to the ERT housing, spin the wriggler one clockwise rotation, then one-counterclockwise
rotation. Do not spin the wriggler more than one complete rotation. The wriggler should spin freely, with
little or no resistance.
5. Hold the index in place and tighten the index mounting screws.
Warning Verify the index is correctly positioned all the way to the right on the index mounting screws
before you tighten the index mounting screws. Failure to properly mount the index on the index mounting
screws may cause binding and meter failure.
6. Install and tighten the mounting screws evenly.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
31
Itron (Sprague) Meter Installation
7. Slide the ERT cover over the index and housing. Verify the cover is installed correctly. The ERT label
should be clearly visible and easily read.
Programming the 100G DLS Gas ERT Module Assembly
Program the 100G DLSs using:

An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or

A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher
or

A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
See the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete
programming information.
FC200SR
FC300 with SRead
900MHz Belt Clip Radio
Caution You must program the 100G DLS gas ERT module before use.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
32
Itron (Sprague) Meter Installation
The ERT is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower
dial on the index. Elster American meter index drive rates are either 1-cubic foot, 2-cubic feet or 0.05 cubic
meters (not shown below).
To program the 100G DLS gas ERT module

Program the meter drive rate into the 100G DLS gas ERT module using the endpoint programming
device.

For all programming and Check Endpoint operations, hold the handheld programmer as close to
vertical as possible. For best success, keep the handheld programmer within 6 feet of the target ERT.

Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode,
Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.
Programming parameters are based on the configuration file loaded into the ERT module programming
device. During programming, the 100G DLS gas ERT module is set to the nearest 100 cubic feet; the last two
digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT assembly will
read to the nearest cubic foot.
Attaching the 100G DLS Gas ERT Module Assembly to the
Meter
After you program the 100G DLS gas ERT module, attach it to the Itron meter.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
33
Itron (Sprague) Meter Installation
To attach the 100G DLS gas ERT module to the meter
1. Align the ERT so one of its four drive fins (1) lines up with the meter drive dog (2).
Warning Failure to correctly align the meter drive post and ERT module wriggler's fin can cause binding
and lead to poor registration or meter failure. If there is a gap between the ERT module gasket and the
meter, it may be the wriggler fin of the ERT module is dead headed against the meter drive dog.
Remove the 100G DLS assembly and repeat the alignment procedure. You must engage the meter drive
dog in the ERT module wriggler fin.
2. Place the 100G DLS on the meter.
3. Insert the right module mounting screw and tighten the screw until the gasket is against the meter. Do not
completely tighten the mounting screw.
Note Use the original mounting screws to mount the 100G DLS if they were the correct size and not
corroded. If you discarded the original screws, use the correct replacement screws (see Installation
Prerequisites on page 12.)
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
34
Itron (Sprague) Meter Installation
4. Slightly lift the left side of the ERT (the module will rotate on the right screw) until the left ERT mounting
hole is approximately 1/4-inch above the left meter mounting hole.
5. Rotate the ERT down until the ERT mounting hole is approximately 1/4-inch below the meter hole.
6. Rotate the ERT up to align the left mounting holes.
7. Insert the left mounting screw and tighten a few turns.
8. Tighten the right and left ERT to meter mounting screws in an alternating pattern.
Important Meter manufacturers: torque the mounting screws 15 to 20 inch-pounds.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
35
Itron (Sprague) Meter Installation
9. Place a new tamper seal in the tamper seal cups surrounding the two mounting screws. Press the new
tamper seals into place using an 11/32-inch nut driver or similar blunt tool.
10. Complete any necessary paperwork and properly dispose excess installation materials and scrap from the
customer premises.
100G DLS gas ERT module installation on the Itron meter is complete.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
36
Itron (Sprague) Meter Installation
Attaching the 100G DLS Gas ERT Module Assembly to Flatfaced Sprague Meters
100G DLS gas ERT module installation on a flat-faced Sprague meter requires the Itron Adapter Plate Kit
(CFG-0015-001).
Itron Adapter Plate Kit (CFG-0015-001)
Adapter Shim Plate
Index Cover Mounting Screws
Drive Dog
Adapter Plate Mounting Screws
To attach the 100G DLS gas ERT module assembly to Flat-faced Sprague meters
1. Verify the kit includes the materials listed in the Itron Adapter Plate Kit table.
Warning The adapter plate must fit flush against the meter face. Some older Sprague meters are not
compatible with the adapter plate. The following examples illustrate the potential obstruction (problem)
areas between the adapter plate and meter. Failure to mount the adapter plate flush on the front of a meter
could result in a binding condition and lead to poor registration or meter failure.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
37
Itron (Sprague) Meter Installation
2. Remove the drive dog from the flat-faced Sprague meter. Replace it with the extended drive dog included
in the kit. Hand-tighten to snug.
Warning The meter drive dog shaft is surrounded by a gasket. A gas leak could result if the gasket is
damaged. Do not use a tool to install or tighten the new drive dog. Hand-tighten only.
3. Attach the adapter plate to the meter with the gasket against the meter face. Secure with the two adapter
plate mounting screws in an alternating fashion. Tighten each adapter plate screw evenly.

Insert the right adapter plate screw and tighten the screw enough to hold it in place.

Install the left mounting screw and tighten to a snug fit.

Finish by tightening the right mounting screw to a snug fit.
Note The 100G DLS must be assembled, programmed, and attached to the meter following the
instructions in Assembling the 100G DLS Gas ERT Module and Index on page 30, Programming the
100G DLS Gas ERT Module Assembly on page 18, and Attaching the 100G DLS Gas ERT Module to
the Meter on page 33. Use the module mounting screws shipped with the Sprague 1A Adapter Plate Kit to
mount the 100G DLS.
Securing Brass Meter Tags to Flat-faced Meters
Some older Sprague meters have metal index covers with brass meter tags attached (by screws or rivets) to
metal index covers.
Typically, brass meter tags have mounting (screw/rivet) holes on each end of the tag.
Mount brass meter tags using one of three Itron-approved methods.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
38
Itron (Sprague) Meter Installation
To secure brass meter tags to flat-faced meters
Method 1 and 2
1. Carefully remove the brass meter tag from the meter index cover. Try not to damage the meter tag
mounting holes.
2. Attach the 100G DLS assembly to the meter. The Sprague adapter plate has tag mounting holes in the
lower left and right corners. Secure the meter tag to one of the holes with a utility-approved and provided
security seal.
Method 1: Attach the meter tag to the adapter plate tag mounting hole
Method 2: Attach the meter tag to the 100G DLS gas ERT module mounting hole
Note If the brass meter tag will be secured to the meter utilizing the ERT-to-meter mounting hole, it must
be attached during the 100G DLS installation procedure described in Step 1 of Attaching the 100G DLS
Gas ERT Module to the Meter on page 33.
Caution A protruding brass meter tag can present a safety concern particularly if the tag is damaged with
sharp edges protruding from the meter.
Method 3
1. Remove the 100G DLS gas ERT module index cover.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
39
Itron (Sprague) Meter Installation
2. Place the meter tag inside the ERT assembly for optimal meter tag security. (See To assemble the 100G
DLS gas ERT module and index on page 30.)
Method 3: Place the brass meter tag inside the 100G DLS assembly
Attaching the 100G DLS gas ERT module Assembly on Sprague
175RM Meters
This section provides the information to install the 100G DLS on a Sprague 175RM meter.
Removing the Meter Index
Begin the ERT module installation by removing the index cover and index from the meter.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
40
Itron (Sprague) Meter Installation
To remove the index from the meter
1. Remove the index cover mounting screws and the index cover from the Sprague 175RM meter. Discard
the index cover and index cover mounting screws.
Note The removed index cover may be used as a temporary refuse container for screws. Properly
dispose the index cover and all unused screws, gaskets, tamper seals, and other leftover
materials. Do not leave materials on customer premises.
2. Loosen the index mounting screws 1/2 to one turn. Slide the index up and off the mounting screws and
remove it from the meter. Set the index aside where it will not be damaged or fill with dirt, rain or snow.
You will mount the index in the module later in this procedure. Remove the index mounting screws from
the meter. Verify the index mounting screws are 1/4-inch long and not corroded. If the screws are the
correct length and not corroded, retain for later use. If the original screws are discarded, use the correct
replacement screws (see Installation Prerequisites on page 12).
3. Remove the old gasket, gasket residue, and dirt from the meter (if applicable). The meter face must be free
of gasket residue or dirt before you install the 100G DLS.
Assembling the ERT Module and Index
Continue ERT module installation by assembling the ERT module and index.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
41
Itron (Sprague) Meter Installation
To assemble the 100G DLS gas ERT module and index
1. Separate the 100G DLS housing from the cover by pulling the cover straight out from the housing. Set the
module cover aside where it will not be damaged or fill with rain, dirt or snow. The cover is used later in
this installation procedure.
2. Screw the index mounting screws into the index mounting posts loosely (one to two turns). Do not tighten
the screws.
3. Align the index wriggler (1) with the ERT module drive post (2).
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount
Proprietary and Confidential
42

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2012:07:11 10:49:18-05:00
Creator                         : Microsoft® Office Word 2007
Modify Date                     : 2012:07:11 10:49:57-05:00
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2012:07:11 10:49:57-05:00
Creator Tool                    : Microsoft® Office Word 2007
Format                          : application/pdf
Document ID                     : uuid:2abbdc72-2c51-49b2-bb30-6262e411c3ee
Instance ID                     : uuid:b9f3c17a-5989-425b-a335-a50b13df0a91
Producer                        : Microsoft® Office Word 2007
Page Count                      : 50
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EWQ100GDLAS