Itron 100GDLD AMR transceiver device for utility meters User Manual 100G Datalogging Installation Guide Direct Mount

Itron, Inc. AMR transceiver device for utility meters 100G Datalogging Installation Guide Direct Mount

Contents

Users Manual Part 1

Download: Itron 100GDLD AMR transceiver device for utility meters User Manual 100G Datalogging Installation Guide   Direct Mount
Mirror Download [FCC.gov]Itron 100GDLD AMR transceiver device for utility meters User Manual 100G Datalogging Installation Guide   Direct Mount
Document ID1114258
Application IDJ9huXY0r1ux0IVyFq/WIzw==
Document DescriptionUsers Manual Part 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize47.24kB (590562 bits)
Date Submitted2009-05-21 00:00:00
Date Available2009-05-27 00:00:00
Creation Date2009-04-22 09:19:11
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2009-04-22 09:19:21
Document Title100G Datalogging Installation Guide - Direct Mount
Document CreatorAcrobat PDFMaker 9.1 for Word
Document Author: Itron

Natural Gas Solutions
100G Datalogging Installation Guide Direct Mount
Identification
100G Datalogging Installation Guide - Direct Mount
03/6/2009 TDC-0823-000
Endpoint Part Numbers: 100G Endpoint: ERG-5000-001, ERG-5000-002, ERG-5000-003, ERG-5000-004, ERG-5000-005, ERG-5000-006, ERG-5000-007, ERG-5000-008
100G Datalogging Endpoint: ERG-5002-001, ERG-5002-002, ERG-5002-003, ERG-5002-004, ERG-5002-005, ERG-5002-006, ERG-5002-007, ERG-5002-008
Copyright
© 2009 Itron, Inc. All rights reserved.
Applicable Patents
U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700
Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118
Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
Compliance Statement
This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. Operation is subject to the following conditions:
• This device may not cause interference.
• This device must accept any interference that may cause undesired operation of the device.
Compliance Statement
This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules. Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Trademark Notice
Itron and Endpoint-Link are registered trademarks of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
•
•
•
•
Mail: Itron, Inc. Attention: Customer Care, 2111 N Molter Road, Liberty Lake, WA 99019
Internet: www.itron.com
E-mail: support@itron.com
Phone: 1 800 635 8725
WARNING! Follow these procedures to avoid injury to yourself or others:
•The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
•Do not recharge, disassemble, heat above 100° Celsius (212° Fahrenheit), or incinerate
the lithium battery.
•Keep the lithium battery away from children.
•Replace the lithium battery only with batteries meeting Itron specifications. Any other battery
may cause a fire or explosion.
WARNING! Only authorized Itron personnel should attempt repairs on Itron equipment.
Attempts to do so by others might void any maintenance contract with your company.
Unauthorized service personnel might also be subject to shock hazard on some Itron equipment
if removal of protective covers is attempted.
WARNING! To prevent ignition of flammable or combustible atmospheres, disconnect power
before servicing.
WARNING! Substitution of components may impair intrinsic safety.
100G Datalogging Installation Guide - Direct Mount
ii
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging Endpoint is considered an operating
transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's
authority to operate the equipment.
Meter Installation/Removal
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
100G Datalogging Installation Guide - Direct Mount
iii
Document Conventions
The following documentation conventions are used:
CAUTION! This type of note warns the user that failure to heed the
information in the note could result in loss of data. Be sure to carefully
read a CAUTION note and heed the advice/instructions.
WARNING! This type of note is used to warn of potential physical harm
to the user or hardware. It is critical that you pay strict attention to
WARNING notes, read the information carefully, and heed the advice,
instructions.
This type of note provides the user with extra hints/tips to make a task
easier to perform or a concept easier to understand.
This type of note supplies generic information to the user. The
information could be ignored and the user could still continue with a task
without suffering any adverse consequences.
100G Datalogging Installation Guide - Direct Mount
iv
Contents
Chapter 1 100G Datalogging Gas Endpoint................................................................ 1
Transmission Modes ........................................................................................................................... 1
Specifications ...................................................................................................................................... 2
Related Documents .................................................................................................................. 2
Meter Compatibility List ....................................................................................................................... 2
Installation Prerequisites ..................................................................................................................... 8
Chapter 2 Elster American Meter Installation........................................................... 11
Programming the 100G Datalogging Gas Endpoint Assembly .........................................................16
Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter .................18
Chapter 3 Sensus/Rockwell Meter Installation......................................................... 21
Programming the 100G Datalogging Gas Endpoint Assembly .........................................................25
Attaching the 100G Datalogging Gas Endpoint Assembly to the Sensus Meter ..............................27
Chapter 4 Itron/Actaris Meter Installation ................................................................. 31
Programming the 100G Datalogging Gas Endpoint Assembly .........................................................34
Attaching the 100G Datalogging Gas Endpoint Assembly to the Itron/Actaris Meter .......................36
Attaching the 100G Datalogging Gas Endpoint Assembly to Flat-faced Itron/Actaris Meters 39
Securing Brass Meter Tags to Flat-faced Meters ...................................................................43
Chapter 5 National/Lancaster Meter Installation ...................................................... 47
Programming the 100G Datalogging Gas Endpoint Assembly .........................................................53
Attaching the 100G Datalogging Gas Endpoint Assembly to the National/Lancaster Meter ............55
Chapter 6 Elster American and Itron Actaris Commercial Meter Installation ........ 57
Removing the Index/ Index Assembly from the Meter ......................................................................58
Programming the 100G Datalogging Commercial Gas Endpoint .....................................................60
Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter 67
Chapter 7 Sensus/Rockwell Commercial Meter Installation ................................... 73
Removing the Index/ Index Assembly from the Meter ......................................................................73
Programming the 100G Datalogging Gas Endpoint ..........................................................................74
Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial
Diaphragm Meter ...............................................................................................................................76
100G Datalogging Installation Guide - Direct Mount
Contents
Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation ......................... 81
Installation Prerequisites .........................................................................................................81
Installation Examples ..............................................................................................................82
Programming the 100G Datalogging Gas Endpoint Assembly .........................................................83
B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive
Programming Information ..................................................................................................................85
B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* ...87
Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser
ROOTS Rotary Meter ........................................................................................................................89
Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter ...90
Programming the 100G Datalogging Commercial Gas Endpoint Assembly ..........................91
B3, LMMA, and S3A CD/TD Dresser ROOTS Series Meter Drive Rates ..............................93
To Attach the 100G Datalogging Commercial Gas Endpoint to the Meter .............................95
Completed Installation Examples............................................................................................97
vi
100G Datalogging Installation Guide - Direct Mount
CHAPTER 1
100G Datalogging Gas Endpoint
Itron 100G Datalogging Gas Endpoints are radio-frequency (RF) devices designed to
transmit meter data to an RF meter reading device within transmission distance of the
endpoint. 100G Datalogging Gas Endpoints have the same increased output power as the
first generation 100G Gas Endpoints for greater RF transmission distance. The 100G directmount endpoint reads and transmits a Standard Consumption Message (SCM) with
magnetic-tamper and tilt-tamper data. The Itron 100G Datalogging direct-mount endpoint
adds functionality by storing up to 40 days of hourly data.
This installation guide provides step-by-step instructions for installing the 100G Gas
Endpoint and the 100G Datalogging Gas Endpoint on a wide variety of meters. This
installation guide refers to both 100G endpoint versions as the 100G Datalogging Endpoint.
Mechanical installation procedures are identical for both modules. 100G Datalogging Gas
Endpoint compatible meters are listed in the Meter Compatibility List.
Transmission Modes
The 100G Datalogging Gas Endpoint transmits in one of three modes:
•
Fixed Network Mode In this mode, a 100G Datalogging Gas Endpoint transmits a
high-powered RF message every 60 seconds. Output power in this mode is 250
milliwatts or +24dBm; expected battery life is 20 years.
•
Mobile and Handheld Mode In this mode, a 100G Datalogging Gas Endpoint
transmits a medium-powered RF message every 15 seconds. Output power in this
mode is 10 milliwatts or +10dBm; expected battery life is 20 years.
•
(Optional) Hard to Read Mobile and Handheld Mode In this mode, a 100G
Datalogging Gas Endpoint transmits a high-powered RF message every 30 seconds.
Output power in this mode is 250 milliwatts or +24dBm; expected battery life
decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode
should only be used for exceptionally hard-to-read applications (such as meters
installed on roof tops or in sub-basements).
An FCC license is not required to read 100G Datalogging Gas Endpoint.
100G Datalogging Installation Guide - Direct Mount
Chapter 1
100G Datalogging Gas Endpoint
Specifications
Functional Specifications
Description
Power Source
100G
100G Datalogging
Tamper Detection
Two "A" cell lithium batteries
One "A" cell lithium battery
FCC Compliance
Part 15 certified
Industry Canada Compliance
RSS-210 certified
Intrinsically Safe per
UL Class I, Division 1, Groups C and D
Product Identification
Numeric and barcoded endpoint type and serial number
Construction Materials
Gray polycarbonate housing and back plate with
encapsulated electronics
Operational Specifications
Description
Operating Temperatures
-40° to 158° F (-40° to +70° C)
Operating Humidity
5 to 95 percent relative humidity
Program Frequency
908 MHz
Transmit Frequency
Spread spectrum 908 to 924 MHz ISM band
Data Integrity
Verified in every data message
Tilt tamper and magnetic tamper
Related Documents
Document Title
Document Part Number
Gas Endpoint Meter Compatibility List
PUB-0117-002
Gas Endpoint Ordering Guide
PUB-0117-001
100G Datalogging Specification Sheet
Publication 100941SP-01
Endpoint Link® Programming Guide
TDC-0744
Meter Compatibility List
The Meter Compatibility table lists meters compatible with the 100G Datalogging Gas
Endpoint. Due to continuous research, product improvements, and enhancements, Itron
reserves the right to change this list without notice.
Note On rare occasions the location of endpoint-to-meter mounting holes on
older diaphragm gas meters might not match up with the mounting holes on the
100G Datalogging Gas Endpoint. This can prevent the 100G Datalogging Gas
Endpoint from properly mounting to the meter.
100G Datalogging Installation Guide - Direct Mount
Meter Compatibility List
Mfg.
100G Series Meter Compatibility List
Model
Description Class
Comments
Endpoint
Type
Endpoint
Part No.
Elster American/
Canadian
W75AL
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AL-175
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AT-175
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
ALC-175
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AT-210
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AL-225
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AL-250
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AR-250
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AC-250
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AM-250
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AL-310
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AL-350
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AT-350
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AL-425
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
AC-630
Residential
Aluminum case meters
only
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
5B 225
Aluminum case
Residential
100G
100G Datalogging
ERG-5000-001
ERG-5002-001
Elster American/
Canadian
35B
Iron case
Commercial
100G
ERG-5000-007
Elster American/
Canadian
60B
Iron case
Commercial
100G
ERG-5000-007
Elster American/
Canadian
80B
Iron case
Commercial
100G
ERG-5000-007
Elster American/
Canadian
250B
Iron case
Commercial
100G
ERG-5000-007
Elster American/
Canadian
500B
Iron case
Commercial
100G
ERG-5000-007
Elster American/
Canadian
AL800
100G
ERG-5000-007
Canada only
Commercial
100G Datalogging Installation Guide - Direct Mount
Must have front reading
index.
Aluminum case meters
only
Chapter 1
100G Datalogging Gas Endpoint
Mfg.
Model
Elster American/
Canadian
Description
Class
Comments
Endpoint
Type
Endpoint
Part No.
AL1000
Commercial
Aluminum case meters
only
100G
ERG-5000-007
Elster American/
Canadian
AL1400
Commercial
Aluminum case meters
only
100G
ERG-5000-007
Elster American/
Canadian
AL2300
Commercial
Aluminum case meters
only
100G
ERG-5000-007
Elster American/
Canadian
AL3000
Commercial
Aluminum case meters
only
100G
ERG-5000-007
Elster American/
Canadian
AL5000
Commercial
Aluminum case meters
only
100G
ERG-5000-007
R-175
11-tooth
Residential
R-200
11-tooth
Residential
RT-200
11-tooth
Residential
RC-225
11-tooth
(Canada only)
Residential
RT-230
11-tooth
Residential
R-275
11-tooth
Residential
RT-275
11-tooth
Residential
R-315
11-tooth
Residential
250
11-tooth
Residential
Sensus/Invensys/
Equimeter/Rockwell
310
11-tooth
Sensus/Invensys/
Equimeter/Rockwell
S-110
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
24- and 30-tooth gears
are not compatible.
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
24- and 30-tooth gears
are not compatible.
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
24- and 30-tooth gears
are not compatible.
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
Residential
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
11-tooth
Residential
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
S-200
11-tooth
Residential
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
175-S
18-tooth
Residential
24- and 30-tooth gears
are not compatible.
100G
100G Datalogging
ERG-5000-004
ERG-5002-004
RT-100
18-tooth
Residential
24- and 30-tooth gears
are not compatible
100G
100G Datalogging
ERG-5000-004
ERG-5002-004
S-190
18-tooth
Residential
24- and 30-tooth gears
are not compatible.
100G
100G Datalogging
ERG-5000-004
ERG-5002-004
24- and 30-tooth gears
are not compatible.
100G Datalogging Installation Guide - Direct Mount
Meter Compatibility List
Mfg.
Model
Description
Class
Sensus/Invensys/
Equimeter/Rockwell
S-120
11-tooth
Sensus/Invensys/
Equimeter/Rockwell
T-120
Sensus/Invensys/
Equimeter/Rockwell
Endpoint
Type
Endpoint
Part No.
Residential
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
11-tooth
Residential
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
T-110
11-tooth
Residential
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
R-415
18-tooth
Residential
100G
100G Datalogging
ERG-5000-004
ERG-5002-004
100G
100G Datalogging
ERG-5000-004
ERG-5002-004
100G
100G Datalogging
ERG-5000-003
ERG-5002-003
100G
100G Datalogging
ERG-5000-003
ERG-5002-003
Sensus/Invensys/
Equimeter/Rockwell
RT-360
18-tooth
Residential
Sensus/Invensys/
Equimeter/Rockwell
MR8
(R-275
Metric)
16-tooth
Residential
Sensus/Invensys/
Equimeter/Rockwell
MR12
(R-415
Metric)
16-tooth
Residential
Sensus/Invensys/
Equimeter/Rockwell
Comments
Older meters may have
endpoint-to-meter
mounting hole variations
that can make them
incompatible.
Sensus/Invensys/
Equimeter/Rockwell
750
Commercial
100G
ERG-5000-008
Sensus/Invensys/
Equimeter/Rockwell
1000
Commercial
100G
ERG-5000-008
Sensus/Invensys/
Equimeter/Rockwell
1600
Commercial
100G
ERG-5000-008
Sensus/Invensys/
Equimeter/Rockwell
3000
Commercial
100G
ERG-5000-008
Sensus/Invensys/
Equimeter/Rockwell
5000
Commercial
100G
ERG-5000-008
Sensus/Invensys/
Equimeter/Rockwell
10000
Commercial
100G
ERG-5000-008
National/ Lancaster
175
Residential
Actaris/Schlumberger/
Sprague direct-read
(odometer) indexes
cannot be used.
100G
ERG-5000-006
National/ Lancaster
U175 UL175
Residential
Actaris/Schlumberger/
Sprague direct-read
(odometer) indexes
cannot be used.
100G
ERG-5000-006
National/ Lancaster
250
Residential
Actaris/Schlumberger/
Sprague direct-read
(odometer) indexes
cannot be used.
100G
ERG-5000-006
Itron/Actaris/
Schlumberger/
Sprague
175
Residential
Index boxes with 3
mounting holes
100G
ERG-5000-005
Itron/Actaris/
Schlumberger/
Sprague
175 WC
Index boxes with 3
mounting holes
100G
ERG-5000-005
3-hole index box
3-hole index box
Residential
100G Datalogging Installation Guide - Direct Mount
Vertical index only
Vertical index only
Vertical index only
Chapter 1
100G Datalogging Gas Endpoint
Mfg.
Model
Description
Class
Comments
Itron/Actaris/
Schlumberger/
Sprague
175
Combination
3-hole index box
Residential
Index boxes with 3
mounting holes
Itron/Actaris/
Schlumberger/
Sprague
210
Itron/Actaris/
Schlumberger/
Sprague
240
Itron/Actaris/
Schlumberger/
Sprague
240
Combination
Itron/Actaris/
Schlumberger/
Sprague
240
Itron/Actaris/
Schlumberger/
Sprague
240
1-hole cover flat
face
Residential
Itron/Actaris/
Schlumberger/
Sprague
240
2-hole cover
Residential
Itron/Actaris/
Schlumberger/
Sprague
250
Itron/Actaris/
Schlumberger/
Sprague
250 WC
Itron/Actaris/
Schlumberger/
Sprague
250
Combination
Integrated
regulator
Residential
Itron/Actaris/
Schlumberger/
Sprague
1A
Flat face
Residential
Itron/Actaris/
Schlumberger/
Sprague
METRIS 250
Itron/Actaris/
Schlumberger/
Sprague
Integrated
regulator
Endpoint
Part No.
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
+ CFG-0015-001
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005 +
Residential
Canadian
Version of 250
Residential
Integrated
regulator
Residential
Residential
Requires Itron 1A
Adapter P/N
CFG-0015-001 Kit
Residential
Residential
Includes 3-dial,
2cf indexes.
3-hole index box
Slant-faced
Residential
305
Combination
Integrated
regulator
Residential
Itron/Actaris/
Schlumberger/
Sprague
400
Slant-faced
Residential
Itron/Actaris/
Schlumberger/
Sprague
400A
Itron/Actaris/
Schlumberger/
Sprague
675A
Top-mount index
Itron/Actaris/
Schlumberger/
Sprague
800A
Top-mount index
Endpoint
Type
Slant-faced
Requires Itron 1A adapter
kit, CFG-0015-001
Index boxes with 3
mounting holes
CFG-0015-001
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
100G
ERG-5000-005
Commercial
100G
Requires Itron/Actaris
adapter p/n 80005901-001;
purchase from
Itron/Actaris
ERG-5000-007
Commercial
100G
Requires Itron/Actaris
adapter p/n 80005901-001;
purchase from
Itron/Actaris
ERG-5000-007
Residential
100G Datalogging Installation Guide - Direct Mount
Meter Compatibility List
Mfg.
Model
Description
Class
Comments
Itron/Actaris/
Schlumberger/
Sprague
1000A
Top-mount index
Commercial
100G
Requires Itron/Actaris
adapter p/n 80005901-001;
purchase from
Itron/Actaris
ERG-5000-007
EMCO
#2 ½
Commercial
100G
ERG-5000-008
EMCO
#3
Commercial
100G
ERG-5000-008
EMCO
#4
Commercial
100G
ERG-5000-008
EMCO
#4 ½
Commercial
100G
ERG-5000-008
EMCO
#5
Commercial
100G
ERG-5000-008
Dresser ROOTS
Series B3
8C - 56M
8C - 16M
CTR
TC
(No pulser, No
instrument drive)
Commercial
To attach an Elster
American endpoint,
install Dresser's Elster
American AMR adapter
kit.
100G
100G Datalogging
Dresser adapter
P/N 059599-000
ERG-5000-001
ERG-5002-001
Dresser ROOTS
Series A1
(LMMA)
CTR
Commercial
To attach an Elster
American endpoint,
install Dresser's Elster
American AMR adapter
kit.
100G
100G Datalogging
Dresser adapter
P/N 058530-610
ERG-5000-001
ERG-5002-001
1.5M - 5M
(No pulser, No
instrument drive)
Endpoint
Type
Endpoint
Part No.
Dresser ROOTS
Series A1
(LMMA)
7M - 16M
CTR
(No pulser
No instrument
drive)
Commercial
To attach an Elster
American endpoint,
install Dresser's Elster
American adapter kit.
100G
100G Datalogging
Dresser adapter
P/N 058531-610
ERG-5000-001
ERG-5002-001
Dresser ROOTS
Series A1
(LMMA)
TC
(No pulser
No instrument
drive)
Commercial
To attach an Elster
American endpoint,
install Dresser's Elster
American AMR adapter
kit.
100G
100G Datalogging
Dresser adapter
P/N 058224-641
ERG-5000-001
ERG-5002-001
1.5M - 16M
Dresser ROOTS
5C/8C15
Series Z compact
meter
Commercial
To attach an Elster
American endpoint,
install Dresser's Elster
American adapter kit.
100G
100G Datalogging
Dresser adapter
P/N 059847-000
ERG-5000-001
ERG-5002-001
Dresser ROOTS
B3/LMMA
Instrument drive
Commercial
Standard index drive and
no instrument.
100G
ERG-5000-007
CD/TD
100G Datalogging Installation Guide - Direct Mount
Chapter 1
100G Datalogging Gas Endpoint
Installation Prerequisites
Prior to installation, verify you have the following items:
1. 100G Datalogging Gas Endpoints designed for your specific brand of residential or
commercial gas meters (endpoints include new tamper seals).
2. A compatible meter (see the Meter Compatibility List on page 2).
3. A compatible index. Itron 100G Datalogging Gas Endpoints are compatible with
standard dial and direct-read (odometer) indexes. Exceptions are noted on the Meter
Compatibility List on page 2.
4. Installation tools (provided by installer or customer)
•
Small and medium flat-blade or Phillips screwdrivers - to remove and tighten
index and index-cover screws.
•
Side-cutting plier/wire snips - to cut wire seals, if applicable.
•
Small putty knife - residential meters.
•
Meter seals, wire seal, and seal press - to protect the meter from tampering, if
applicable.
•
11/32-inch nut driver or other blunt tool - to securely seat new tamper plugs
over screw holes.
•
FC200SR handheld computer with Endpoint-Link® or EndPoint-Link Pro®
software - to program and check 100G Datalogging Gas Endpoint installation
and operation.
Caution The 100G Datalogging Gas Endpoints can only be programmed using
®
®
FC200SR Handheld Computers loaded with EndPoint-Link or EndPoint-Link Pro
software version 5.3 or later.
100G Datalogging Installation Guide - Direct Mount
Installation Prerequisites
•
Replacement screws - to mount the 100G Datalogging Gas Endpoint assembly
to the meter and the index to the endpoint housing:
Replacement Screws
Meter
To mount the 100G
Datalogging Gas
Endpoint on the meter:
Itron Part
Number
Elster American
1/4 - 20 x 5/8" slotted,
Fillister head
8 - 32 x 3/16" slotted, round
pan-head
Sensus/Rockwell
10 - 24 x 5/8" slotted
Fillister head
6 - 32 x 5/8" slotted, round
pan-head
Itron/Actaris
10 - 24 x 5/8" slotted
Fillister head
10 - 24 x 1/4" slotted, round
pan-head
National/Lancaster
10 - 24 x 3/4" Phillips flathead stainless steel
SCR-0014-004
To mount the index on the Itron Part
100G Datalogging Gas
Number
Endpoint housing:
6 - 19 x 3/8" thread-forming,
Phillips pan-head to mount
indexes with legs
6 - 19 x 3/8" thread-forming,
Phillips, Fillister head to
mount indexes with screw
holes
Commercial
Meter
Elster American
Sensus/Rockwell
To mount the 100G
Datalogging
Commercial endpoint
on the meter:
SCR-0015-001
SCR-0037-001
Itron Part
Number
To mount the index (and
Itron Part
index assembly, if
Number
applicable) on the 100G
Datalogging Commercial
endpoint housing:
2A x 3.25" length, slotted
SCR-0062-001
12 - 24 x 1/2" slotted, Fillister
round-head drilled to accept (Elster American) head machine screws, drilled
utility-approved wire seals
to accept utility-approved wire
seals
2A x 3.63" length, slotted
SCR-0062-002
round-head drilled to accept
utility-approved wire seals
100G Datalogging Installation Guide - Direct Mount
2A x 2.94" length, slotted
round-head
SCR-0062-003
Chapter 1
10
100G Datalogging Gas Endpoint
100G Datalogging Installation Guide - Direct Mount
CHAPTER 2
Elster American Meter Installation
This chapter provides instructions to install the 100G Datalogging Gas Endpoint on an
Elster American Meter.
Installing the 100G Datalogging Gas Endpoint involves four tasks:
1. Removing the index from the meter.
2. Assembling the 100G Datalogging Gas Endpoint and index.
3. Programming the 100G Datalogging Gas Endpoint assembly.
4. Attaching the 100G Datalogging Gas Endpoint assembly to the meter.
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals,
and other leftover materials. Do not leave materials on customer premises.
To remove the index from the meter
1. Remove the four index cover screws and the index cover from the Elster American
meter. Alternate screw removal following the numbered pattern in the photo.
100G Datalogging Installation Guide - Direct Mount
11
Chapter 2
Elster American Meter Installation
2. Examine the mounting screws. If they are 5/8" long and not corroded, keep them to reattach the 100G Datalogging Gas Endpoint assembly. If the screws are not the correct
length or if the screws are corroded, discard.
Note You may use the removed index cover as a temporary storage container for
screws. Properly dispose all unused screws, old index covers, gaskets, tamper
seals, and other leftover materials. Do not leave materials on customer premises.
3. Unscrew one index mounting screw completely. Hold one hand under the index to
catch the screw. While removing the other mounting screw, pull the index away from
the meter to keep the index backplate against the back of the screw. Remove the screw
completely after the index is free of the meter.
Set the index aside where it will not be damaged or fill with dirt, rain or snow. The
index will be mounted to the endpoint later in this procedure. Verify the index
mounting screws are 3/16" long and not corroded. If the screws are the correct length
and not corroded, retain for later use. If the original screws were discarded, use the
correct replacement screws (see Installation Prerequisites on page 8.)
4. Remove the old gasket, gasket residue and dirt from the meter (if applicable). The
meter face must be free of gasket residue before you install the 100G Datalogging Gas
Endpoint.
12
100G Datalogging Installation Guide - Direct Mount
Installation Prerequisites
To Assemble the 100G Datalogging Gas Endpoint and Index
1. Separate the 100G Datalogging Gas Endpoint housing from the cover by pulling the
cover straight out from the housing.
2. Set the endpoint cover aside where it will not be damaged or fill with rain, dirt or
snow. The cover will be used later in this installation procedure.
100G Datalogging Installation Guide - Direct Mount
13
Chapter 2
Elster American Meter Installation
Note Elster American meter indexes are available in different models:
Index wrigglers on one-foot meters
with drive slots
Index meters on two-foot meters
with drive posts
An Elster American index with
mounting screw holes
An Elster American index with
mounting slots
If your index has mounting screw slots, skip steps 3 and 4. If your index has mounting
screw holes, perform steps 3 and 4, and skip steps 5 and 6.
3. Using the original index mounting screw or a replacement screw, if necessary, place
one 8 - 32 3/16" screw into the index's right-hand mounting screw hole.
14
100G Datalogging Installation Guide - Direct Mount
Installation Prerequisites
4. Attach the screw to the endpoint housing's right-index mounting post just enough to
hold the screw and the right end of the index in place.
5. Screw one 8 - 32 x 3/16" screw into the right index mounting post one or two turns.
Do not tighten the screw.
6. Place the right index mounting screw slot under the screw head. Do not tighten the
screw.
7. Slide the index drive post into the endpoint wriggler. Verify positive engagement.
Caution If the index wriggler has a drive slot, place the endpoint wriggler's drive
post into the index drive slot. Failure to mate the endpoint wriggler with the index
drive post (or slot) can cause binding and lead to poor registration or meter failure.
8. Install and tighten the left index mounting screw (for indexes with either mounting
screw slots or holes). Tighten the right index mounting screw.
100G Datalogging Installation Guide - Direct Mount
15
Chapter 2
Elster American Meter Installation
9. Slide the endpoint cover over the index and housing. Verify the cover is installed
correctly. The endpoint label should be clearly visible and easily read.
Programming the 100G Datalogging Gas Endpoint Assembly
The 100G Datalogging Gas Endpoint must be programmed with the FC200SR
handheld computer loaded with EndPoint-Link® or Point-Link Pro® software version
5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide
(TDC-0744) for more complete programming information.
Caution The 100G Datalogging Gas Endpoint must be programmed before use.
Follow the steps in this section to properly program the endpoint.
16
100G Datalogging Installation Guide - Direct Mount
Programming the 100G Datalogging Gas Endpoint Assembly
The endpoint is programmed based on the meter's drive rate. Take note of the index drive
rate shown on a lower left dial on the index. The endpoint is programmed based on the drive
rate. Elster American meter index drive rates are either 1-cubic foot or 2-cubic feet.
To Program the 100G Datalogging Gas Endpoint
1. Program the meter drive rate into the 100G Datalogging Gas Endpoint using the
FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR
as close to vertical as possible. For best success, keep the FC200SR within 6 feet of
the target endpoint. Verify you have the correct programming mode (Fixed Network
Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your
application. Programming parameters are based on the mode defined by your system
administrator.
During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100
cubic feet; the last two digits (tens and units) are programmed as zeros (0). After
programming is complete, the endpoint assembly will read to the nearest cubic foot.
2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the
index drive rate. This verifies the endpoint is counting properly after assembly.
Caution Do not turn the drive wriggler faster than one turn per second.
3. Read the 100G Datalogging Gas Endpoint using the FC200SR.
•
If the read result is higher than the number programmed in Step 1, the 100G
Datalogging Gas Endpoint is counting correctly.
•
If the read result is not higher than the number programmed in Step 1, replace
the 100G Datalogging Gas Endpoint.
100G Datalogging Installation Guide - Direct Mount
17
Chapter 2
Elster American Meter Installation
Attaching the 100G Datalogging Gas Endpoint Assembly to
the Elster American Meter
After 100G Datalogging Gas Endpoint programming is complete, attach the endpoint
assembly to the Elster American Meter.
Warning For 5B Meters only: If the 100G Datalogging Gas Endpoint
will be installed on a 5B-225 aluminum meter, cut 1/16" off each
endpoint wriggler post to prevent the wriggler from rubbing on the face
of the nut holding the meter drive dog in place.
To Attach the 100G Datalogging Gas Endpoint
1. Align the endpoint wriggler to connect with the drive post (or slot) of the meter.
For one-foot meters: Align the endpoint assembly wriggler perpendicular to the meter
drive post.
For two-foot meters: Align the endpoint assembly wriggler perpendicular to the meter
drive slot. The pin on the endpoint wriggler may be installed inside or outside the
meter drive slot. For easy assembly, Itron recommends installing the pin on the 100G
Datalogging Gas Endpoint wriggler outside the meter drive slot.
18
100G Datalogging Installation Guide - Direct Mount
Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter
2. Carefully align the endpoint's four screw holes with the holes on the meter. Attach
using the original mounting screws if they are the correct size and are not corroded
(1/4 - 20 x 5/8" screws.) If the original screws were discarded, use the correct
replacement screws (see Installation Prerequisites on page 8). Tighten in an
alternating, diagonal pattern as shown in the photo:
•
Insert first screw and tighten 1/4 to 1/2 turn after the screw contacts the meter
connection.
•
Insert the second screw and tighten 1/4 to 1/2 turn after contact with the meter
connection.
•
Insert the third screw and tighten 1/4 to 1/2 turn after contact with the meter
connection.
•
Insert the last screw and tighten 1/4 to 1/2 turn after contact with the meter
connection.
Return to the first screw and tighten. Continue with the second, third and last screw
until all screws are tight. Use equal screw tension to tighten each screw.
Note Meter manufacturers should torque the mounting screws 15 to 20 inchpounds.
3. Place new tamper seals over the two screws with tamper seal mounts. Press tamper
seals into place using the 11/32" nut driver or similar blunt tool.
100G Datalogging Installation Guide - Direct Mount
19
Chapter 2
Elster American Meter Installation
4. Complete necessary paperwork and verify all excess materials are removed from the
customer's premises. 100G Datalogging Gas Endpoint installation on the Elster
American meter is complete.
20
100G Datalogging Installation Guide - Direct Mount

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Itron
Create Date                     : 2009:04:22 09:19:11-05:00
Modify Date                     : 2009:04:22 09:19:21-05:00
Subject                         : Gas Solutions
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2009:04:22 09:19:21-05:00
Creator Tool                    : Acrobat PDFMaker 9.1 for Word
Format                          : application/pdf
Title                           : 100G Datalogging Installation Guide - Direct Mount
Description                     : Gas Solutions
Creator                         : Itron
Document ID                     : uuid:1dde0f21-cd0d-4660-9002-f82c8e44ea28
Instance ID                     : uuid:b7c9006c-cc00-4800-9356-172335e1c56f
Producer                        : Adobe PDF Library 9.0
Page Count                      : 26
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EO9100GDLD

Navigation menu