Itron 100GDLD AMR transceiver device for utility meters User Manual 100G Datalogging Installation Guide Direct Mount
Itron, Inc. AMR transceiver device for utility meters 100G Datalogging Installation Guide Direct Mount
Itron >
Contents
- 1. Users Manual Part 2
- 2. Users Manual Part 3
- 3. Users Manual Part 1
Users Manual Part 3
CHAPTER 6 Elster American and Itron Actaris Commercial Meter Installation This chapter provides instructions to install the 100G Datalogging Gas Endpoint on Elster American and Itron/Actaris Commercial Meters. Warning Handle the commercial 100G Datalogging Gas Endpoint carefully so the metal passive radiator antenna is not damaged. 100G Datalogging Installation Guide - Direct Mount 57 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation Removing the Index/ Index Assembly from the Meter Commercial 100G Datalogging Gas Endpoints can be mounted on Elster American Meters in various configurations. These instructions show metal mounting plates without tamper seal cups and plastic mounting plates with tamper seal cups to represent mounting plate options. Mounting plate with tamper seal cups Mounting plate without tamper seal cups Indexes may be mounted on the 100G Datalogging Commercial Elster American Gas Endpoint without mounting plates. Index covers may (or may not) have tamper seal cups (on the back of the cover) for added security. Index removal assumes the installer will remove any tamper seals or wires before continuing with these instructions. Note It may not be necessary to dismantle your commercial index assembly (index and cover). These instructions do not include index/cover assembly for those applications. Some diaphragm commercial meters do not require an index assembly mounting plate. Indexes can be mounted directly to the endpoint. 58 100G Datalogging Installation Guide - Direct Mount Removing the Index/ Index Assembly from the Meter To Remove the Index Assembly 1. Remove any tamper seals (1) (or wire seals) from the index cover and mounting plate screws (2). Set the index/cover assembly aside. You will re-install it later in these instructions. 2. Remove the index cover screws from the meter. Verify screws are 1/2" long and are not corroded. If the screws are the correct length and are not corroded, keep them to re-install the 100G Datalogging Gas Endpoint assembly later in this procedure. If the screws are damaged or not the correct length, discard. Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises. 100G Datalogging Installation Guide - Direct Mount 59 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation 3. Remove the gasket from the index cover mounting plate (if applicable). Set it aside where it will not be damaged. Remove the tamper seals from the mounting plate. Remove the mounting plate screws and separate the mounting plate from the meter. Place the mounting plate where it will not be damaged. You will use it later in this installation. Programming the 100G Datalogging Commercial Gas Endpoint The 100G Datalogging Gas Endpoint must be programmed with the FC200SR handheld computer loaded with EndPoint-Link® or Point-Link Pro® software version 5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide (TDC-0744) for more complete programming information. Caution The 100G Datalogging Commercial Endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint. 60 100G Datalogging Installation Guide - Direct Mount Programming the 100G Datalogging Commercial Gas Endpoint Take note of the index drive rate shown on the index. The endpoint is programmed based on the drive rate. Elster American commercial meter index drive rates may be 5-, 10- or 100 cubic feet. To Program the 100G Datalogging Commercial Gas Endpoint 1. Program the index drive rate into the 100G Datalogging Gas Endpoint using the FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR as close to vertical as possible. For best success, keep the FC200SR within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the mode defined by your system administrator. During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot. 2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly. Caution Do not turn the drive wriggler faster than one turn per second. 100G Datalogging Installation Guide - Direct Mount 61 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation 3. Read the 100G Datalogging Gas Endpoint using the FC200SR. • If the read result is higher than the number programmed in Step 1, the 100G Datalogging Gas Endpoint is counting correctly. • If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging Gas Endpoint. To Attach the 100G Datalogging Commercial Gas Endpoint to the Elster American Commercial Meter Warning Handle the 100G Datalogging Commercial Gas Endpoint carefully so the metal passive radiator antenna is not damaged. 1. Tilt the 100G Datalogging Commercial Gas Endpoint at an angle and turn the wriggler until the drive notches line up with the meter wriggler's drive teeth. 62 100G Datalogging Installation Guide - Direct Mount Programming the 100G Datalogging Commercial Gas Endpoint 2. Align the endpoint so the screw holes line up with the meter's top screw holes. Carefully lower the endpoint on the meter with the wriggler notches lining up with the meter's wriggler teeth. Warning The INLET label on the 100G Datalogging Commercial Gas Endpoint must line up with the INLET label on the meter case. 3. Verify the bottom of the endpoint and the top of the meter meet. The endpoint housing should rest on top of the meter without gaps. Warning Do not press down on the 100G Datalogging Commercial Gas Endpoint if a gap exists between the endpoint and the meter. A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, slowly turn the endpoint's upper wriggler back and forth until the endpoint aligns with the meter's drive teeth. 100G Datalogging Installation Guide - Direct Mount 63 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation 4. Place the index cover mounting plate on the commercial 100G Datalogging Gas Endpoint so the printing "FLOW FRONT AL800 AL1000 AL1400 AL2300 AL5000 TURBINE ROTARY" stamped on the plate is toward the front of the meter. (A gap between the mounting plate and meter at the screw locations is normal.) 5. Install four mounting screws (SCR-0062-001 - see Installation Prerequisites on page 8 for screw information) and tighten them in an alternating diagonal sequence. For metal mounting plates with a flat screw surface, use endpoint mounting screws with internal tooth washers. For plastic mounting plates with tamper screw cups, use endpoint mounting screws (AS-568A-011, 5/16" ID x 7/16" OD o-rings may be used for a maximum moisture seal). Turn each screw 1/4 to 1/2 turn after it contacts the mounting plate. If you have access to a torque driver, tighten mounting screws to 72 inch-pounds. 6. Place new tamper seals over screws (if mounting plate has tamper seal cups) and press into place with an 11/32" nut driver or similar blunt tool. 64 100G Datalogging Installation Guide - Direct Mount Programming the 100G Datalogging Commercial Gas Endpoint To Attach the Index/Cover Assembly on the Elster American Commercial Meter 1. Place the mounting plate gasket (previously removed) on the index cover mounting plate. Align the gasket and index cover mounting plate screw holes. 2. Place the index/cover assembly on the index mounting plate. (The index must face the direction it faced before removal.) Attach the index/cover assembly on the mounting plate using original index screws. Insert one screw and tighten two turns to hold it in place on the mounting plate. Insert the second mounting screw and tighten until secure. Completely tighten the first mounting screw. Each index cover mounting screw must be tightened evenly. 3. Turn the commercial 100G Datalogging Gas Endpoint wriggler so it intersects with the index wriggler. Carefully lower the index-cover mounting plate assembly onto the 100G Datalogging Gas Endpoint. 4. Install four endpoint mounting screws (SCR-0062-001, see Installation Prerequisites on page 8). Tighten screws in an alternating diagonal pattern. • Insert the first screw and tighten enough to hold index assembly in place. • Insert the second screw diagonal to first screw and tighten two to three turns. • Insert the third screw, tightening two or three turns. • Insert the fourth screw and tighten until secure. • Tighten the first, 2nd, and third screw until secure. Turn each screw 1/4 to 1/2 turn after it contacts the cover. Each endpoint mounting screw must be tightened evenly. If you have access to a torque-driver, tighten mounting screws to 72-inch pounds. 100G Datalogging Installation Guide - Direct Mount 65 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation 5. Install new tamper or wire seals. If tamper seals are installed, press into place with an 11/32 nut driver or similar blunt tool. Crimp the seal if utility-approved wire seals are installed. This completes installation of the 100G Datalogging Commercial Gas Endpoint on an Elster American Commercial meter. 66 100G Datalogging Installation Guide - Direct Mount Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter This section provides instructions for installing the 100G Datalogging Commercial Gas Endpoint on Itron/Actaris 675A, 800A, and 1000A commercial meters. Installation requires an Itron/Actaris adapter kit from Itron/Actaris. Itron/Actaris Adapter Kit (Part Number 80005901-01) Adapter plate Endpoint mounting screws (4) Screw bushings (4) Tamper seals Extension driver Before You Begin Follow To Remove the Index/Index Assembly from the Meter on page 57 to prepare the Itron-Actaris meter for installation. Program the Commercial 100G Datalogging Gas Endpoint (see Programming the 100G Datalogging Gas Endpoint Assembly on page 60) prior to installation. 100G Datalogging Installation Guide - Direct Mount 67 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation To Attach the 100G Datalogging Commercial Gas Endpoint to the Meter 1. Turn the 100G Datalogging Commercial Gas Endpoint over and place the four mounting screw bushings into the screw holes on the endpoint. 2. Turn the 100G Datalogging Commercial Gas Endpoint on its side and align the wriggler with the Itron-Actaris Commercial meter's drive dog. 68 100G Datalogging Installation Guide - Direct Mount Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter 3. Inlet lettering on the 100G Datalogging Commercial Gas Endpoint must line up with Inlet lettering on the meter. Slowly lower the endpoint on the Itron-Actaris Commercial meter aligning the drive dog and wriggler. The endpoint housing should rest on the top of the meter without gaps. Warning Do not press down on the 100G Datalogging Gas Endpoint if a gap exists between the endpoint and the meter. A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, remove the 100G Datalogging Gas Endpoint and repeat steps 2 and 3. To Attach the Index on the Itron-Actaris Commercial Meter 1. Place the Itron-Actaris adapter plate on the 100G Datalogging Commercial Gas Endpoint with the two small screw holes in the adapter plate to the back of the meter. Meter Front 100G Datalogging Installation Guide - Direct Mount 69 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation 2. Place the extension driver on the 100G Datalogging Commercial Gas Endpoint wriggler. 3. Align the index wriggler with the commercial 100G Datalogging Commercial Gas Endpoint wriggler driver extension. 4. Install the two index mounting screws. Tighten the first screw two or three turns. Install second screw and tighten to secure. Tighten the first screw to a snug fit. Each index mounting screw must be tightened evenly. 70 100G Datalogging Installation Guide - Direct Mount Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter 5. Place the index cover over the index with the clear side covering the index dials for easy reading. Align the holes in the index cover with the endpoint adapter plate mounting holes. Secure with the four mounting screws from the adapter kit. Tighten the mounting screws in a diagonal alternating pattern. • Insert the first screw and tighten enough to hold the index in place. • Insert the second screw and tighten two to three turns. • Insert the third mounting screw and tighten two to three turns. • Insert the fourth mounting screw and tighten. Tighten the first, third and second screw. Turn each screw 1/4 to 1/2 turn after the screw contacts the index cover. Each index mounting screw must be tightened evenly. If you have access to a torque-driver, tighten mounting screws to 72-inch pounds. 6. Insert tamper seals in the tamper seal cups on the index cover and press into place with an 11/32 nut driver or similar blunt tool. 100G Datalogging Installation Guide - Direct Mount 71 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation This completes installation of the commercial 100G Datalogging Gas Endpoint on the ItronActaris Commercial meter. 72 100G Datalogging Installation Guide - Direct Mount CHAPTER 7 Sensus/Rockwell Commercial Meter Installation This chapter provides instructions to install the 100G Datalogging Commercial Gas Endpoint on a Commercial Sensus/Rockwell diaphragm meter. Removing the Index/ Index Assembly from the Meter 100G Datalogging Commercial Gas Endpoints can be mounted on Sensus/Rockwell Commercial Meters in various configurations. These instructions show the index assembly mounted without a mounting plate. Note Sensus/Rockwell diaphragm commercial meters do not require an index assembly mounting plate. Indexes can be mounted directly to the endpoint. To Remove the Index/Index Assembly from the Meter 1. Remove any tamper seals (or wire seals) from the index cover and remove the index cover mounting screws. You will re-install it later in these instructions. 100G Datalogging Installation Guide - Direct Mount 73 Chapter 7 Sensus/Rockwell Commercial Meter Installation 2. Remove the index screws from the meter. Set the index cover aside where it will not be damaged or fill with dirt, rain or snow. You will re-install the index later in this procedure. Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises. Programming the 100G Datalogging Gas Endpoint The 100G Datalogging Commercial Endpoint must be programmed with the FC200SR handheld computer loaded with EndPoint-Link® or Point-Link Pro® software version 5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide (TDC-0744) for more complete programming information. Caution The 100G Datalogging Commercial Sensus/Rockwell Endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint. 74 100G Datalogging Installation Guide - Direct Mount Programming the 100G Datalogging Gas Endpoint Take note of the index drive rate shown on the index. The endpoint is programmed based on the drive rate. Sensus/Rockwell commercial meter index drive rates may be 5-, 10- or 100cubic feet. The seven-dial index shown is a 100-cubic feet drive rate. To Program the 100G Datalogging Commercial Gas Endpoint 1. Program the index drive rate into the commercial endpoint using the FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR as close to vertical as possible. For best success, keep the FC200SR within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the mode defined by your system administrator. During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot. 2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly. Caution Do not turn the drive wriggler faster than one turn per second. 3. Read the 100G Datalogging Gas Endpoint using the FC200SR. • If the read result is higher than the number programmed in Step 1, the 100G Datalogging Gas Endpoint is counting correctly. • If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging Gas Endpoint. 100G Datalogging Installation Guide - Direct Mount 75 Chapter 7 Sensus/Rockwell Commercial Meter Installation Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphragm Meter Warning Handle the 100G Datalogging Commercial Gas Endpoint carefully so the metal passive radiator antenna is not damaged. To Attach the 100G Datalogging Commercial Endpoint 1. Tilt the 100G Datalogging Commercial Gas Endpoint at an angle and turn the wriggler until the drive notches line up with the meter wriggler's drive teeth. 2. Align the 100G Datalogging Commercial Gas Endpoint so the screw holes line up with the meter's top screw holes. Carefully lower the endpoint on the meter so the wriggler's bars line up with the meter drive dog. Itron recommends installation with one bar inserted into the meter drive dog's u-shaped gear. Warning The INLET label on the 100G Datalogging Commercial Gas Endpoint must line up with the INLET label on the Sensus/Rockwell meter case. 76 100G Datalogging Installation Guide - Direct Mount Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphragm Meter 3. Verify the bottom of the 100G Datalogging Commercial Gas Endpoint and the top of the meter meet. The endpoint housing should rest on top of the meter without gaps. Warning Do not press down on the 100G Datalogging Commercial Gas Endpoint if a gap exists between the endpoint and the meter. A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, slowly turn the 100G Datalogging Commercial Gas Endpoint's upper wriggler back and forth until the endpoint aligns with the meter's drive teeth. 4. Align the 100G Datalogging Commercial Gas Endpoint with the index mounting holes. Verify the index drive dog intersects with the endpoint's wriggler. Install the endpoint mounting screws (SCR-0062-003 see Installation Prerequisites on page 8 for screw information). Turn each screw 1/4 to 1/2 turn after it contacts the index/endpoint assembly. 100G Datalogging Installation Guide - Direct Mount 77 Chapter 7 Sensus/Rockwell Commercial Meter Installation 5. Install the index cover. For index covers with flat-surface screw holes, use screws (SCR-0062-002), flat washers (WSH-0020-005), and cork washers (WSH-0032-001). For index covers with tamper seal cups, use screws, (AS-568A-011, 5/16" ID x 7/16 OD) o-rings, and tamper seals. 6. Place new tamper seals over screws (if mounting plate has tamper seal cups) and press into place with an 11/32" nut driver or similar blunt tool. If your mounting assembly requires a utility-approved wire seal, pass wires through holes in the screw heads and crimp the approved wire seal. 78 100G Datalogging Installation Guide - Direct Mount Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphragm Meter This completes installation of the 100G Datalogging Gas Endpoint on the Sensus/Rockwell Commercial Diaphragm meter. 100G Datalogging Installation Guide - Direct Mount 79 Chapter 7 80 Sensus/Rockwell Commercial Meter Installation 100G Datalogging Installation Guide - Direct Mount CHAPTER 8 Dresser ROOTS Commercial Rotary Meter Installation This chapter provides the instructions to mount 100G Datalogging Gas Endpoints (residential and commercial) on Dresser ROOTs Commercial Rotary Meters. Some commercial AMR applications require a Dresser ROOTS Rotary Meter with a residential 100G Datalogging Gas Endpoint. Only Elster American version residential 100G Datalogging Gas Endpoints are compatible with Dresser ROOTS series rotary gas meters. This chapter provides the instructions to mount an Elster American residential 100G Datalogging Gas Endpoint on Dresser ROOTS AMR-ready Rotary Commercial Meters. Installation requires an AMR adapter kit supplied by Dresser. Refer to the Meter Compatibility List on page 2 for Dresser AMR adapter kit part numbers. Installation Prerequisites Materials Supplied By Itron • 100G Datalogging Gas Endpoint • New tamper seals - if applicable Materials Supplied by You • AMR-ready Dresser ROOTS Rotary Meter • Adapter Kit from Dresser Note Follow the Dresser Field Installation Instructions to modify the AMR-ready Dresser ROOTS Meter for 100G Datalogging Gas Endpoint installation. Contact Dresser distributor or Dresser representative for installation instructions specific to the required AMR adapter kit. 100G Datalogging Installation Guide - Direct Mount 81 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation Installation Examples The following pictures show typical installations. Dresser B3 CTR/TC Dresser LMMA CTR Dresser LMMA TC Dresser 8C15 82 100G Datalogging Installation Guide - Direct Mount Programming the 100G Datalogging Gas Endpoint Assembly Programming the 100G Datalogging Gas Endpoint Assembly The 100G Datalogging Gas Endpoint must be programmed with the FC200SR handheld computer loaded with EndPoint-Link® or Point-Link Pro® software version 5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide (TDC-0744) for more complete programming information. Caution The 100G Datalogging Gas Endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint. The endpoint is programmed based on the meter's drive rate. See B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information on page 85. To Program the 100G Datalogging Gas Endpoint 1. Program the meter drive rate into the 100G Datalogging Gas Endpoint using the FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR as close to vertical as possible. For best success, keep the FC200SR within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the mode defined by your system administrator. During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot. 100G Datalogging Installation Guide - Direct Mount 83 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation 2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly after assembly. Caution Do not turn the drive wriggler faster than one turn per second. 3. Read the 100G Datalogging Gas Endpoint using the FC200SR. 84 • If the read result is higher than the number programmed in Step 1, the 100G Datalogging Gas Endpoint is counting correctly. • If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging Gas Endpoint. 100G Datalogging Installation Guide - Direct Mount B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information Use the information in the following tables to program Dresser Roots Series B3, LMMA, and S3A Non-compensated Counter (CTR) and Temperature Compensated Counter (TC) registers. Reference the Meter Compatibility List on page 2 to confirm compatibility. Settings for Series B3 Registers Model CTR Meter size 8C-15C and 2M-11M Settings Number of dials: 5 Drive rate: 10 PCOMP factor: NONE 16M-56M Number of dials: 6 Drive rate: 100 PCOMP factor: NONE TC 8C-15C and 2M-11M Number of dials: 5 Drive rate: 100 PCOMP factor: NONE 16M Number of dials: 6 Drive rate: 1000 PCOMP factor: NONE 100G Datalogging Installation Guide - Direct Mount 85 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation Settings for LMMA Registers Model CTR Meter size 1.5M-11M Settings Number of dials: 5 Drive rate: 10 PCOMP factor: NONE 16M Number of dials: 6 Drive rate: 100 PCOMP factor: NONE TC 1.5M-11M Number of dials: 5 Drive rate: 50 PCOMP factor: NONE 16M Number of dials: 6 Drive rate: 500 PCOMP factor: NONE Settings for Series S3A Registers Model CTR Meter Size 1.5M - 11M Settings Number of dials: 5 Drive rate: 10 PCOMP factor: NONE 16M Number of dials: 6 Drive rate: 100 PCOMP factor: NONE TC 1.5M - 11M Number of dials: 5 Drive rate: 100 PCOMP factor: NONE 16M Number of dials: 6 Drive rate: 1000 PCOMP factor: NONE 86 100G Datalogging Installation Guide - Direct Mount B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* B3 CTR Meter Size 8C B3 CTR Meter Drive Rate 10 11C 10 15C 10 2M 10 3M 10 5M 10 7M 10 11M 10 16M 100 23M 100 38M 100 56M 100 Drive rates in this table are for direct-mount residential style endpoints only (NOT commercial or remote endpoints). B3 TC Meter Size 8C B3 TC Meter Drive Rate 100 11C 100 15C 100 2M 100 3M 100 5M 100 7M 100 11M 100 16M 1000 LMMA CTR Meter Size 1.5M LMMA CTR Meter Drive Rate 3M 10 5M 10 7M 10 11M 10 16M 100 10 100G Datalogging Installation Guide - Direct Mount 87 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation LMMA TC Meter Size 1.5M LMMA TC Meter Drive Rate 50 3M 50 5M 50 7M 50 11M 50 16M 500 S3A CTR Meter Size 1.5M S3A CTR Meter Drive Rate 10 3M 10 5M 10 7M 10 11M 10 16M 100 S3A TC Meter Size 1.5M S3A TC Meter Drive Rate 100 3M 100 5M 100 7M 100 11M 100 16M 1000 Note S3A rotary meters are LMMA meters retrofitted with Series 3 End Bell Adapter. 88 100G Datalogging Installation Guide - Direct Mount Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser ROOTS Rotary Meter Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser ROOTS Rotary Meter After 100G Datalogging Gas Endpoint programming is complete, attach the 100G Datalogging residential endpoint assembly to the Dresser ROOTS Rotary Meter. This mounting procedure applies to B3 CTR/TC, LMMA CTR/TC, and 8C15 series Dresser ROOTS Meters. To Attach the 100G Datalogging Gas Endpoint 1. The 100G Datalogging Gas Endpoint must be mounted on the adapter plate in an upright position. Align the 100G Datalogging Gas Endpoint wriggler with the opening between the tabs of the adapter's drive dog. Insert one endpoint mounting screw and tighten enough to hold the endpoint. Do not completely tighten. Insert the second mounting screw and tighten two turns. Insert the third mounting screw and tighten two turns. Insert the last mounting screw and tighten until snug. Tighten the remaining mounting screws in an alternating, diagonal pattern until snug. All mounting screws must be tightened evenly. Warning A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, remove the endpoint assembly and re-align the endpoint wriggler with the meter drive dog. 2. Complete necessary paperwork and verify all excess materials are removed from the customer's premises. 100G Datalogging Residential Gas Endpoint installation on the Dresser ROOTS Rotary Meter is complete. 100G Datalogging Installation Guide - Direct Mount 89 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter The information in this section guides you through the installation of the 100G Datalogging Commercial Gas Endpoint on Dresser ROOTS rotary meters. Note A Dresser ROOTS rotary gas meter with an instrument drive is required for this installation procedure. These instructions show an Elster American 100G Datalogging Commercial Gas Endpoint. The installation procedure is the same for the Sensus/Rockwell 100G Datalogging Commercial Gas Endpoint. 100G Datalogging Elster American Commercial Gas Endpoint 100G Datalogging Sensus/Rockwell Commercial Gas Endpoint Installation Requisites Installation requires the following items: 90 • Drive cover kit • 100G Datalogging Commercial Gas Endpoint • A flat, slot-drive screwdriver 100G Datalogging Installation Guide - Direct Mount Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter Programming the 100G Datalogging Commercial Gas Endpoint Assembly The 100G Datalogging Commercial Gas Endpoint must be programmed with the FC200SR handheld computer loaded with EndPoint-Link® or Point-Link Pro® software version 5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide (TDC-0744) for more complete programming information. Caution The 100G Datalogging Commercial Gas Endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint. The endpoint is programmed based on the meter's drive rate. See B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information on page 93. To Program the 100G Datalogging Commercial Gas Endpoint 1. Program the meter drive rate into the 100G Datalogging Commercial Gas Endpoint using the FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR as close to vertical as possible. For best success, keep the FC200SR within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the mode defined by your system administrator. During programming, the 100G Datalogging Commercial Gas Endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot. 100G Datalogging Installation Guide - Direct Mount 91 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation 2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly after assembly. Caution Do not turn the drive wriggler faster than one turn per second. 3. Read the 100G Datalogging Commercial Gas Endpoint using the FC200SR. 92 • If the read result is higher than the number programmed in Step 1, the 100G Datalogging Commercial Gas Endpoint is counting correctly. • If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging Commercial Gas Endpoint. 100G Datalogging Installation Guide - Direct Mount Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter B3, LMMA, and S3A CD/TD Dresser ROOTS Series Meter Drive Rates Use the information in the following tables to program 100G Datalogging Commercial Endpoints installed on Dresser Roots Series B3, LMMA, and S3A Non-compensated Counter with Instrument Drive (CD) and Temperature Compensated Counter with Instrument Drive (TD) registers. Reference the Meter Compatibility List on page 2 to confirm compatibility. Warning Drive rates listed in the following tables are for commercial endpoint programming. Do not use these settings to program residential or remote endpoints. B3 CD Meter Size 8C B3 CD Meter Drive Rates 10 11C 10 15C 10 2M 10 3M 10 5M 10 7M 10 11M 10 16M 100 23M 100 38M 100 56M 100 B3 TD Meter Size B3 TD Meter Drive Rate 8C 100 11C 100 15C 100 2M 100 3M 100 5M 100 7M 100 11M 100 16M 1000 100G Datalogging Installation Guide - Direct Mount 93 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation LMMA CD Meter Size 1.5M LMMA CD Meter Drive Rate 10 3M 10 5M 10 7M 10 11M 10 16M 100 LMMA TD Meter Size 1.5M LMMA TD Meter Drive Rate 100 3M 100 5M 100 7M 100 11M 100 16M 1000 S3A CD Meter Size 1.5M S3A CD Meter Drive Rate 100 3M 100 5M 100 7M 1000 11M 100 16M 1000 S3A TD Meter Size 1.5M S3A TD Meter Drive Rate 100 3M 100 5M 100 7M 100 11M 100 16M 1000 Note S3A rotary meters are LMMA meters retrofitted with Series 3 End Bell Adapter. 94 100G Datalogging Installation Guide - Direct Mount Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter To Attach the 100G Datalogging Commercial Gas Endpoint to the Meter Note A cover is installed on the 100G Datalogging Commercial Gas Endpoint mounted to a Dresser ROOTS Meter with S3A LMMA Accessory Units (or other Dresser ROOTs adapters with odometer gauges). 1. Locate the INSTRUMENT FACE stamp (2) and position the meter with the drive dog (1) aligned (as shown). Warning Handle the commercial 100G Datalogging Commercial Gas Endpoint carefully so the metal passive radiator antenna is not damaged. 2. Locate the INLET (1) stamp on the endpoint and position the endpoint as shown. Verify the 100G Datalogging Commercial Gas Endpoint wriggler (3) and drive dog shaft (2) are aligned. 100G Datalogging Installation Guide - Direct Mount 95 Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation 3. Verify the endpoint wriggler and drive dog shaft are engaged by turning the commercial endpoint wriggler. When properly engaged, you will feel resistance. 4. Place the index mounting plate on the endpoint and install the four mounting screws. Do not disturb the shaft alignment. 5. Install the four 100G Datalogging Commercial Gas Endpoint mounting screws (supplied with the commercial endpoint). Tighten mounting screws in an alternating, diagonal sequence. • Turn each screw 1/4 to 1/2 turn after it contacts the cover. • If you can utilize a torque wrench, tighten to 72 inch-pounds. Each endpoint mounting screw must be tightened evenly. 6. Insert new utility-approved wire seals and crimp (if required). Note To mount an index and index cover on a rotary meter without an accessory odometer unit, remove the domed cover and reference To Attach the Index on the Itron-Actaris Commercial Meter on page 69. 96 100G Datalogging Installation Guide - Direct Mount Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter Completed Installation Examples 100G Datalogging Elster American Commercial Gas Endpoint mounted on a Dresser ROOTS Meter 100G Datalogging Sensus/Rockwell Commercial Gas Endpoint mounted on a Dresser ROOTS Meter 100G Datalogging Installation Guide - Direct Mount 97
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Itron Create Date : 2009:04:22 09:17:40-05:00 Modify Date : 2009:04:22 09:18:12-05:00 Subject : Gas Solutions Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2009:04:22 09:18:12-05:00 Creator Tool : Acrobat PDFMaker 9.1 for Word Format : application/pdf Title : 100G Datalogging Installation Guide - Direct Mount Description : Gas Solutions Creator : Itron Document ID : uuid:5cd0280f-e6b5-4982-ac9f-8d0556119a8f Instance ID : uuid:17d69fbe-9bea-4793-b6a0-284b045789af Producer : Adobe PDF Library 9.0 Page Count : 41EXIF Metadata provided by EXIF.tools