Itron 963 Gas Pulse Interface User Manual Commercial Industrial Gas Meter IMU Interface

Silver Spring Networks Gas Pulse Interface Commercial Industrial Gas Meter IMU Interface

Contents

User Manual

Download: Itron 963 Gas Pulse Interface User Manual Commercial   Industrial Gas Meter IMU Interface
Mirror Download [FCC.gov]Itron 963 Gas Pulse Interface User Manual Commercial   Industrial Gas Meter IMU Interface
Document ID408270
Application IDmJHCYif3U+V280+By5hX7g==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.89kB (273589 bits)
Date Submitted2004-04-23 00:00:00
Date Available2004-04-27 00:00:00
Creation Date2004-03-25 03:01:41
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2004-03-25 03:03:11
Document TitleCommercial & Industrial Gas Meter IMU Interface
Document CreatorAcrobat PDFMaker 5.0 for Word
Document Author: Innovatec Corporation

Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
Commercial & Industrial Gas Meter IMU Interface
Operational/Installation and Specification Manual
Silver Spring Networks AxisPathTM Network
FCC ID:OWS-963
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
Copyright  2003 Silver Spring Networks, Inc.
13000 West Silver Spring Drive
Butler, Wisconsin 53007
Phone: 262-783-0200
Fax: 262-783-0205
Internet: www.silverspringnetworks.com
FCC WARNING STATEMENT
Note: This equipment has been tested and found to comply with the limits for Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential/office installation. The equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures.
•
•
•
•
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or an experienced Radio/TV technician for help
CAUTION
Changes or modifications not expressly approved by Silver Spring Networks, Inc.
could void the user’s authority to operate the equipment.
The antenna on this device is professionally installed.
The device is not for sale to the general public and
is installed by professionally trained utility employees.
Note
The device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1.
The device may not cause harmful interferences.
2.
The device must accept any interference received, including interference that may cause undesired operation.
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
INSTRUCTIONS TO INSTALLERS AND USERS
Minimum Safe Distance:
20cm (7.87 inches)
Antenna Mounting:
Antenna as supplied by Manufacturer must not be mounted at a
location such that any person or persons can come closer than the
above indicated minimum safe distance to the antenna.
Antenna Substitution:
Do not substitute any antenna for the one supplied by the
manufacturer. You may be exposing persons to harmful radiation.
Contact supplier or manufacturer for further instructions.
Confidentiality Statement: The information, graphics, and materials in this document are confidential and proprietary.
Document Revision Number: 1.0.2
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
Contents______________________________________________
Preface……………………………………………………………………………………………………. iv
Organization of Manual………………………………………………………………………………… iv
Documentation Conventions…………………………………………………………………………… iv
PART I
C&I Gas Interface Theory and Installation
Chapter 1 Theory of Operation……………………………………………………………………
C&I Gas Interface Purpose……………………………………………………………………….
Functionality………………………………………………………………………………………
Components……………………………………………………………………………………….
Chapter 2
1-1
1-1
1-1
1-1
Specifications…………………………………………………………………………… 2-1
Chapter 3 Installation and Initialization………………………………………………………….. 3-1
Introduction………………………………………………………………………………………. 3-1
Safety Information………………………………………………………………………………... 3-1
Installation Procedures……………………………………………………………………………. 3-2
Equipment Needs……………………………………………………………………………… 3-2
Download Work Orders from the Utility Network……………………………………………. 3-2
Before Installation……………………………………………………………………………… 3-3
C&I Gas Interface End-Point Device Installation……………………………………………... 3-4
Complete and Close the Task………………………………………………………………….. 3-9
After Installation……………………………………………………………………………… 3-10
Chapter 4
Troubleshooting………………………………………………………………………… 4-1
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
Preface_______________________________________________
Organization of Manual
This manual is divided in the following manner:
• “C&I Gas Meter Interface Theory and Installation”, provides information specific to the IMU end-point device.
• “Theory of Operation”, containing a basic overview of the Silver Spring Networks AxisPathTM network and how
the C&I Gas Meter Interface end-point device functions within the network.
• “Installation and Initialization”, containing step-by-step IMU end-point device installation and initialization
instructions.
• “Troubleshooting”, containing IMU-specific system troubleshooting information.
Document Conventions
This document uses a number of conventions designed to help communicate specific information. These conventions
include the following:
•
Danger, Warning, and Caution:
DANGER!
Danger messages alert you to situations that will cause
personal injury or death if you do not follow the instructions
correctly.
WARNING!
Warnings alert you to situations that may potentially cause
personal injury or death if you do not follow the directions
correctly.
CAUTION
Cautions alert you to situations that may result in damage to
the hardware or software if you do not follow the
instructions correctly.
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
Chapter 1___________________________________________________
Theory of Operation
C&I Gas Meter Interface Purpose
The C&I Gas Meter Interface is a programmable end-point device, designed to replace or supplement a customer’s
existing mechanical utility meter index. Using a magnetic pulse output adapter to interface to the meter output, it can
be installed on a variety of meter brands.
The C&I Gas Meter Interface end-point device allows for accurate, near-real-time customer utility use information,
which can be read from a remote location.
Functionality
The C&I Gas Meter Interface end-point device performs two basic functions:
•
Gathering and recording customer utility use information directly at the metering point.
•
Sending and receiving messages to and from the utility company computer system such as:
Utility use, status, alarm data, and similar information.
Data requests, configuration, and verification messages.
C&I Gas Meter Interface end-point devices communicate with the utility company computer system using a
combination of Local Area Networks (LAN), AxisGateTM nodes, and a Wide Area Network (WAN).
Components
C&I Gas Meter Interfaces are Silver Spring Networks end-point devices, containing two primary components: a
digital processor and a radio transceiver.
The digital processor within the end-point device gathers and records utility use data at the metering point. Every time
the meter drive rotates, pulses are recorded by the digital processor. The pulses are converted into utility use data, and
this data is stored until readings are requested from the utility.
Each C&I Gas Meter Interface also contains a 900MHz two-way radio frequency (RF) transceiver. This radio
provides communication between the end-point device, and an AxisGateTM node. Depending upon the communication
distance involved, and Silver Spring Networks relay might be used between the end-point device and the node, to
extend RF communications. This RF connection between the end-point device and the node, possibly through a relay,
is a Local Area Network (LAN).
AxisGateTM nodes then communicate with the rest of the AxisPathTM network using a Wide Area Network (WAN).
This communication allows C&I Gas Meter Interfaces to transmit use data to the utility, or to receive requests or
programming instructions from the utility, or from a technician or installer using a Field Service Unit attached to a
laptop computer.
See Silver Spring Networks publication 98-00004 (System Summary) for a more detailed explanation of
communications on the Local Area Network (LAN) and Wide Area Network (WAN).
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
Chapter 2_____________________________________________
Technical Specifications
•
•
•
•
•
•
•
•
•
•
•
•
•
C&I Gas Meter Interface Features
Full Two-way 900 MHz spread-spectrum communications between the IMU and the utility
Direct sequence spread-spectrum communication improves security
17 channels allow frequency coordination in dense applications with minimal interference
Software programmable configuration and control profiles
3.6-volt lithium-based long life battery pack
Unique serial number and assignable PIN
Autonomous tamper alarms
Professionally installed antenna
Virtual Shut-off capabilities
Run-away meter detection
First/Final Reading
Customer Selectable Billing Dates
Data and Intelligence Stored in the Meter
Item
Specification
Physical dimensions
Weight
Power supply
Output power
Sensitivity
Channels
Frequency range
Modulation
Base data rate
Compliance
Interface
Antenna type
Enclosure
Temperature range
6.67”L X 4.76”W X 2.19”H
2.7 lbs.
(3) 3.6 volt D-cell lithium-based battery pack
20 dBm
>40 dBm SINAD
17 (spaced at 1.5 MHz)
903 to 927 MHz
Direct Sequence Spread Spectrum
62.5 KB / second
FCC Part 15, Class C
RF LAN
External – Professionally Installed
Lexan NEMA 4X Enclosure
-40° to +85°C
FCC ID:OWS-963
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
Chapter 3_____________________________________________
Installation and Initialization
Introduction
This section includes a set of detailed procedures for installation, configuration, and testing.
CAUTION
Read and study the following safety information before you
proceed with installation. In addition, cautions and warnings
appear within procedures and throughout the test, where
appropriate, to remind you of any related safety information.
Safety Information
•
•
•
•
•
•
•
•
•
Observe the following safety guidelines. Careful planning of every job is essential. Nothing should be taken for
granted. Do not take chances!
Read and follow all approved policies and procedures provided by your employer associated with the procedures
in this manual.
Keep the work area clean and dry. Cluttered work areas cause accidents and injuries.
Provide good lighting in the work area. You cannot work safely if you cannot see what you are doing.
Report unsafe conditions or defective equipment to your immediate supervisor.
Select the right tool for the job. Use tools properly. Keep tools in good working order.
Handle materials carefully. Lift and carry properly.
Keep unauthorized people out of the work area. Be especially cautious of children, who tend to be drawn to work
activity.
Silver Spring Networks Inc. assumes no liability for the customer’s failure to follow these safety guidelines.
Equipment Needs
This section lists, and briefly describes, the various pieces of equipment required for C&I Gas Meter Interface endpoint device installation, initialization, and testing processes.
• Laptop computer-Runs the FSA software, which stores and retrieves work order information, and configures and
tests installed C&I Gas Meter Interfaces.
• Field Service Unit-900 MHz two-way radio frequency (RF) transceiver, allowing communication with an IMU for
initialization.’
Before Installation
Field Service Unit Set-Up
The Field Service Unit is a 900 MHz two-way radio frequency (RF) transceiver, used for configuring and
testing Silver Spring devices.
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
After arriving at the customer site, activate and test the Field Service Unit as follows:
CAUTION
DO NOT turn the Field Service Unit ON if
the antenna is not installed. Damage to
the Field Service Unit will result.
1.
Plug the Field Service Unit connection cord into the serial port of the laptop computer.
2.
Plug a 9 VDC / 500 mA power supply into the Field Service Unit power socket.
CAUTION
Using anything other than a 9 VDC /
500 mA power source may damage the
Field Service Unit.
3.
Turn on the Field Service Unit. An indicator light will shine if the
Field Service Unit power supply is functioning correctly.
Installation Procedure
1.
2.
3.
Remove index register from C&I gas meter. For American, Rockwell and Sprague meters, remove the index
register and replace with the Pulsimatic pulse output register or the RioTronics index register with pulse output.
For a Roots meter interface, attach the appropriately modified register head with pulse output to the meter before
installing the pulse output pickup device.
Attach the Silver Spring Networks C&I Gas Meter Interface (p/n 1620-05001) to a surrounding fixture to the gas
meter. Fixturing locations can include the meter piping, meter fixturing brackets or surrounding structures.
Attach the cable assembly from the Pulsimatic or RioTronics pulse output generator to the Silver Spring Networks
C&I Gas Meter Interface (p/n 1620-05001). The cable assembly attaches with a ‘push and twist’ lock for the
weather-resistant seal.
Start the Field Service Application
Note
See Silver Spring Networks publication 98-00001 (Field Service Application User’s Guide) for a more detailed
explanation of FSA operation.
1.
2.
3.
Turn on the laptop computer.
Launch the FSA software. No error messages will display if the connection between the computer and the Field
Service Unit is working.
Log in to the Field Service Application.
Install the Pulse Output Interface Device
For American/Sprague and Rockwell meters, interface with either the Pulsimatic pulse output adapter or the
RioTronics adapter.
• Install the Pulsimatic unit in line with the index register and upon installation of the unit, replace the index register
on top of the Pulsimatic.
• Install the RioTronics-enabled index register in place of the existing index register.
For Dresser Industries’ Roots meters, please follow the instructions for installation of the RioTronics Interface module.
Install the Silver Spring Networks C&I Gas Meter Interface radio device to the surrounding structure which can
include the meter piping, meter fixtures/supports or some adjacent structure to the meter.
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
FCC ID:OWS-963
Connect the meter pulse output device to the C&I Gas Meter Interface by using the weather-resistant cable assembly
from the pulse output device.
Setup the Radio for Communication through the Gateway
Applicant: Silver Spring Networks, Inc.
Gas Pulse Interface
Chapter 4_____________________________________________
Troubleshooting
Table 3-1 Troubleshooting the C&I Gas Meter Interface
Problem
Possible Solution
C&I Gas Meter Interface fails to
respond to the Field Service
Application (FSA).
C&I GMI end-point device ID mis-match
RF channel mis-match
Replace C&I GMI end-point device
Table 3-2 Troubleshooting the Laptop Computer/Field Service Unit
Problem
Possible Solution
Laptop computer does not power up
Charge/replace battery
Laptop computer does not start up
properly and/or the Field Service
Application cannot be found.
Field Service Unit does not power up
Contact System Administrator
Check power source and power circuit
connections.
Table 3-3 Troubleshooting the Field Service Application (FSA)
Problem
Possible Solution
Error message displays when Field
Service Application (FSA) starts up.
Check field service unit connection.
FCC ID:OWS-963

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2004:03:25 03:03:11-08:00
Create Date                     : 2004:03:25 03:01:41-08:00
Page Count                      : 11
Creation Date                   : 2004:03:25 03:01:41-08:00
Mod Date                        : 2004:03:25 03:03:11-08:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Innovatec Corporation
Metadata Date                   : 2004:03:25 03:03:11-08:00
Creator                         : Innovatec Corporation
Title                           : Commercial & Industrial Gas Meter IMU Interface
Page Mode                       : UseNone
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OWS-963

Navigation menu