Itron INTELISG AMR transceiver device for utility meters User Manual Installation Guide

Itron Inc AMR transceiver device for utility meters Installation Guide

Users Manual

OpenWay® Riva Intelis Gas MeterInstallation GuideTechnicalCommunicationsknowledge to shape your future
IdentificationOpenWay® Riva Intelis Gas Meter Installation Guide23 May 2018TDC-1782-000Copyright© 2018 Itron, Inc. All rights reserved.Confidentiality NoticeThe information contained herein is proprietary and confidential and is being providedsubject to the condition that (i) it be held in confidence except to the extent requiredotherwise by law and (ii) it will be used only for the purposes described herein. Any thirdparty that is given access to this information shall be similarly bound in writing.Trademark NoticeItron is a registered trademark of Itron, Inc.All other product names and logos in this documentation are used for identification purposesonly and may be trademarks or registered trademarks of their respective companies.SuggestionsFor more information about Itron or Itron products, see www.itron.com.If you have questions or comments about the software or hardware product, contact ItronTechnical Support Services.Contact• Email: support@itron.com• Internet: support.itron.com• Telephone Itron Technical Support North America: 1-877-487-6602For technical support contact information by region, go to www.itron.com and select yourcountry and language.
ContentsChapter 1  Important Safety and Compliance Information.............................. 1USA, FCC Part 15 compliance............................................................................................................................. 1Canada, ISED compliance.................................................................................................................................... 2RF Exposure (FCC/ISED)...................................................................................................................................... 2Electromagnetic compatibility...............................................................................................................................2Intrinsic safety.......................................................................................................................................................3Lithium battery...................................................................................................................................................... 3Transportation classication................................................................................................................................. 3Electrostatic discharge..........................................................................................................................................3Electrostatic ignition hazard..................................................................................................................................3Device cleaning.....................................................................................................................................................4Do Not Drop .........................................................................................................................................................4Product notication...............................................................................................................................................5Chapter 2  The OpenWay® Riva Intelis Gas Meter........................................... 6OpenWay Riva Intelis Gas Meter models............................................................................................................. 6Intelis meter components..................................................................................................................................... 6OpenWay Riva Intelis Gas Meter LCD....................................................................................................... 7Integrated 500G ERT module.....................................................................................................................8Internal shut off valve................................................................................................................................. 8Auto disconnect conguration............................................................................................................9Intelis meter specications................................................................................................................................... 9Intelis meter dimensions .................................................................................................................................... 10Chapter 3  Installing the Intelis Meter.............................................................. 11Prior to start-up...................................................................................................................................................11Start-up...............................................................................................................................................................11The Intelis meter capacity and pressure loss test.............................................................................................. 12Chapter 4  Proving and Calibrating the Intelis Meter......................................13Prover types........................................................................................................................................................13Proving operations..............................................................................................................................................14Conguring Test Mode.............................................................................................................................14Entering Test Mode.................................................................................................................................. 14Recording prover consumption................................................................................................................15Exiting Test Mode.....................................................................................................................................15Adjusting the Intelis meter calibration......................................................................................................15Chapter 5  OpenWay Riva Intelis Gas Meter Maintenance.............................16OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 iiiProprietary and Confidential
Chapter 1 Important Safety and ComplianceInformationThis section provides important information for your safety and product compliance.USA, FCC Part 15 complianceThis device complies with Part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation.Operation is subject to the following two conditions:• This device may not cause harmful interference.• This device must accept any interference that may cause undesirable operation.This device must be installed to provide a separation distance of at least 20 centimeters (7.9inches) from all persons to be compliant with regulatory RF exposure.USA, FCC Class B-Part 15This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, uses, and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiveris connected.• Consult the dealer or an experienced radio or TV technician for help.Modifications and RepairsTo ensure system performance, this device and antenna shall not be changed or modifiedwithout the express approval of Itron. Per FCC rules, unapproved modifications or operationbeyond or in conflict with these instructions for use could void the user's authority to operatethe equipment.OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 1Proprietary and Confidential
Canada, ISED complianceCompliance Statement Canada Déclaration de ConformitéThis device complies with Innovation, Scienceand Economic Development Canada (ISED)license-exempt RSS standard(s). Operation issubject to the following two conditions: (1) thisdevice may not cause interference, (2) thisdevice must accept any interference, includinginterference that may cause undesired operationof the device.Under Innovation, Science and EconomicDevelopment Canada (ISED) regulations, thisradio transmitter may only operate using anantenna of a type and maximum (or lesser) gainapproved for the transmitter by Industry Canada.To reduce potential radio interference to otherusers, the antenna type and its gain should be sochosen that the equivalent isotropically radiatedpower (e.i.r.p.) is not more than that necessaryfor successful communication.Le présent appareil est conforme aux CNRd'Industrie Canada applicables aux appareilsradio exempts de licence. L'exploitation estautorisée aux deux conditions suivantes: (1)l'appareil ne doit pas produire de brouillage, (2)l'utilisateur de l'appareil doit accepter toutbrouillage radioélectrique subi, même si lebrouillage est susceptible d'en compromettre lefonctionnement.Conformément à la réglementation d'IndustrieCanada, le présent émetteur radio peutfonctionner avec une antenne d'un type et d'ungain maximal (ou inférieur) approuvé pourl'émetteur par Industrie Canada. Dans le but deréduire les risques de brouillage radioélectrique àl'intention des autres utilisateurs, il faut choisir letype d'antenne et son gain de sorte que lapuissance isotrope rayonnée équivalente (p.i.r.e.)ne dépasse pas l'intensité nécessaire àl'établissement d'une communicationsatisfaisante.RF Exposure (FCC/ISED)This equipment complies with radiation exposurelimits set forth for an uncontrolled environment.This equipment should be installed and operatedwith minimum distance 20 cm between theradiator and your body. This transmitter must notbe co-located or operating in conjunction withany other antenna or transmitter.Cet équipement est conforme aux limitesd'exposition aux radiations dans unenvironnement non contrôlé. Cet équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps. Cet émetteurne doit pas être co-localisées ou opérant enconjonction avec tout autre antenne outransmetteur.Electromagnetic compatibilityCaution: Use only approved accessories with this equipment. All cables must behigh quality, shielded, and correctly terminated. Unapproved modifications oroperation beyond or in conflict with these use instructions may void the authority'sauthorization to operate the equipment.Important Safety and Compliance InformationOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 2Proprietary and Confidential
Intrinsic safetyWarning: Substitution of components may impair intrinsic safety.Lithium batteryWarning: Follow these procedures to avoid injury to yourself or others.• The lithium battery may cause a fire or chemical burn if it is not disposed ofproperly.• Do not recharge, disassemble, heat above 100°C Celsius (212°Fahrenheit),crush, expose to water, or incinerate the lithium battery. Fire, explosion, andsevere burn hazard.• The battery used in this device may present a risk of fire or chemical burn ifmistreated.• Keep the lithium battery away from children.• Batteries must not be replaced or modified in any way.Transportation classificationThe Federal Aviation Administration prohibits operating transmitters and receivers on allcommercial aircraft. When powered, the Itron device is considered an operating transmitterand receiver and cannot be shipped by air. All product returns must be shipped by groundtransportation.Electrostatic dischargeWarning: Internal circuit components can be sensitive to electrostatic discharge.Before installation, discharge electrostatic buildup by touching a metal pipe or otherearth-grounded metal object prior to touching the meter body, register housing, orItron device.Electrostatic ignition hazardWarning: Verify the area is not hazardous when installing, servicing, cleaning, ortouching the Itron device.Important Safety and Compliance InformationOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 3Proprietary and Confidential
Device cleaningWarning: Clean only with a damp cloth.Do Not DropWarning: While Itron modules are designed to withstand a drop, dropping themodule may damage the device and void the warranty.Important Safety and Compliance InformationOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 4Proprietary and Confidential
Product notificationWarning: These instructions are suggested when Itron-approved utility or installercompany-established valve installation procedures and practices are not available.The meter installation must comply with all state and local building and safetyregulations as well as federal regulations including Section 192.353 of Title 49 of theCode of Federal Regulations. The two pertinent paragraphs of the code are:• Each meter and service regulator, whether inside or outside of a building must bein a readily accessible location and be protected from corrosion and otherdamage.• Each meter installed within a building must be located in a ventilated place andnot less than 3 feet from any source of ignition or any source of heat which mightdamage the meter.The use of this meter outside of the temperature range from -30° to 120° is notrecommended. Direct customer inquiries as to the selection and application of gasmeters to your local Itron sales representative or Itron Support.• Itron does not endorse or warrant the completeness or accuracy of any third-partyvalve installation procedures or practices, unless otherwise provided in writing byItron.• Follow your company's standard operating procedures regarding the use ofpersonal protection equipment (PPE).• Adhere to guidelines issued by your company in addition to those given in thisdocument when installing or repairing valves.• This product, as of the date of manufacture, is designed and tested to conform toall governmental and industry safety standards as they may apply to themanufacturer.• The purchaser and user of this product must comply with all fire control, buildingcodes, and other safety regulations governing the application, installation,operation, and general use of this valve to avoid leaking gas hazards resultingfrom improper installation, startup, or use of this product.• To ensure safe and efficient operation of this product, Itron strongly recommendsinstallation by a qualified professional.Important Safety and Compliance InformationOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 5Proprietary and Confidential
Chapter 2 The OpenWay® Riva Intelis GasMeterThe OpenWay® Riva Intelis Gas Meter is a solid state static meter featuring built-intemperature conversion, an integrated shut off valve, and an integrated OpenWay Riva500G communications module for extended datalogging capability. The Intelis metersupports the listed functionality.• Ability to switch to network modes• Perform local firmware download• Support basic meter functionality. Basic metering functionality returns information for thelisted parameters.◦ Utility ID◦ Index reading (single index)◦ Count rate◦ Index rollover◦ Pressure compensation◦ Security level◦ Output power◦ Bubble up rateThe Intelis meter is configured for Mobile Mode with support for a combined 100G andOpenWay Riva 500G population. This compact meter weighs about 4-1/2 pounds andmounts on existing meter footprints for easy meter installation and replacement of existinggas meters.OpenWay Riva Intelis Gas Meter modelsThe Intelis gas meter is available in the listed types.• Temperature compensated• Non-temperature compensatedThe Intelis meter is identifiable by a customer-specified serial number that allows thecustomer to audit their inventory of Intelis meters through a report from the OpenWayCollection Manager.Intelis meter componentsThe Intelis residential gas meter features these components in a compact solid state meter.• Integrated OpenWay Riva 500G communications for RF reading in Mobile Mode.• An internal shut off valve.OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 6Proprietary and Confidential
OpenWay Riva Intelis Gas Meter LCDThe Intelis meter LCD provides a visual display through a liquid crystal display (LCD). TheLCD:• Displays a 5-digit plus three (in CCF) in NTC or TC measurement.◦ NTC meters display Vm.◦ TC meters display Vb.• Displays different menu pages in a pre-defined sequence.◦ The time each menu page is active is configurable.◦ When the last menu page is reached, the process loops to the first menu page until theconfigured timeout is reached.Note: Two additional menu pages provide overflow condition information and aninterface to perform an LCD test. The LCD test is initiated by a long press. Theseadditional menu pages are not a part of the normal sequence.• Displays current alarms.Note: X (1) indicates the number of currently active alarms. Before the display moves tothe next menu page, all active alarms are displayed. If there are no alarms, NO ALARMdisplays.Available alarms include:◦ Backflow◦ Overflow◦ Magnetic tamper◦ Temperature◦ Valve◦ 123 (alarm code)• Displays current volume consumption measured under an alarm condition.The OpenWay® Riva Intelis Gas MeterOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 7Proprietary and Confidential
• Menu 8. Displays the UMU and meter firmware versions.• Menu T. Checkerboard test mode for a visual confirmation that the LCD is functioningcorrectly.◦ 1. After 500 ms.◦ 2. After 500 ms.Integrated 500G ERT moduleThe integrated 500G radio-frequency (RF) gas ERT module is designed to operate in MobileMode and be read by ChoiceConnect handheld readers, mobile collection, or the ItronMobile Radio connected to a user-supplied computer or Bluetooth device.Note: The 500G communication functionality is dependent on the module's firmwareversion.Internal shut off valveThe Intelis internal shut-off valve in located on the outlet of the meter. The shut off valve is asafety feature automatically triggered if the meter is configured for automatic shut off.Note: It is mandatory that an on-site technician is at the meter to re-open the valve andensure safe conditions before the flow of gas is resumed after an automatic shut off.The OpenWay® Riva Intelis Gas MeterOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 8Proprietary and Confidential
Auto disconnect configurationThe Intelis gas meter can be configured for an automatic shut off for the following eventtypes.• High flow. Configuration for a high flow event enables an automatic shut off if the highflow threshold is reached or exceeded.• High temperature. Configuration for a high temperature enables an automatic shut off ifthe high temperature threshold is reached or exceeded.Intelis meter specificationsThis section lists the OpenWay Riva Intelis Gas meter product specifications.Specification Specification valueMeter capacity 250 cubic feet per hourMeasurement principle Ultrasonic time of flightGas type Natural gas Type E, H, LHub center-to-center 6 inchesHub size options • 10LT• 20LT• 30LT• 1A/Standard• 1-1/4"• ISO G 1-1/4"Meter MAOP 5 PSIGMeter type Temperature compensated (TC) or non-temperaturecompensated (NTC)Intrinsically safe UL Class I, Div 1LCD displayed units CCF (100 x cubic foot) or cubic meterLCD resolution 00000.001 CCF (0.1 CF) or 00000.001 m3Accuracy Class 1 and ±0.5% at room temperatureCase Aluminum case with ASA 49 gray powder coat finishValve Gate valve, maximum 0.035 CFH leakage rate (14% ofpilot flow)Pulse width 10 ms - 1000 ms (1 second)Pulse weight (volume per pulse) 0.10 CF, 0.25 CF, 0.50 CF, 1.0 CF, 10 dm3, 50 dm3Operating temperature ratings Measurement -30° F (-34° C) to +131° F (55° C)Valve -13° F (-25° C) to +131° F (55° C)500G -40° F (-40° C) to +158° F (70° C)Storage temperature ratings Measurement -40° F (-40° C) to +131° F (55° C)Valve -40° F (-40° C) to +131° F (55° C)500G -40° F (-40° C) to +158° F (70° C)The OpenWay® Riva Intelis Gas MeterOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 9Proprietary and Confidential
Specification Specification valueBattery information 4 A cell Lithium manganese dioxide (LiMn02) 'A' cellbatteries, replaceableBattery life 20 years for meter, 500G, and valve using recommendedoperating parametersPressure tap 1/8" NPT pipe plug pressure tap standard on meter outletBadging Standard aluminum manufacturing and optional customerbadgeIntelis meter dimensionsThis section lists the Intelis meter dimensions.A B C D E F G8.4 6.3 6.0 5.5 3.1 9.1 1.9Note: All dimensions are approximate.The OpenWay® Riva Intelis Gas MeterOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 10Proprietary and Confidential
Chapter 3 Installing the Intelis MeterThis section provides the Intelis meter installation information.Warning: This product, as of the date of its manufacture, is designed and tested toconform to all governmental or industry safety standards then existing as well asmay apply to the manufacturer. The purchaser and user of this product are warnedthat compliance with the manufacturer's instructions and procedures is required inorder to avoid the hazards of leaking gas resulting from improper installation, start-up, or use of this product, and further, that all fire control, building codes, or othersafety regulations established under public laws which regulate or govern theapplication, installation, operation, or general use of this product, should becomplied with. In order to ensure the safe and proper operation of this product, themanufacturer recommends that a qualified technician install this product.The Intelis meter must be installed with the inlet to the left, the outlet to theright, the meter in a horizontal position and with the LCD facing out.Prior to start-upRead the meter badge data regarding maximum allowable operating pressure and capacityflow rate to be sure the meter meets the installation requirements.Sight across both swivel flanges or test with a suitable bar to determine that they arenominally in the same plane and will not cause excessive strain on the meter or piping whenthe connection nuts are tightened.Start-up1. Blowout the service lines before the meter is installed to ensure no dirt, debris, or liquidsof any kind will be carried into the meter when the gas is flowing in the line.2. Place a new connection washer (gasket) on each swivel pilot.OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 11Proprietary and Confidential
3. Support the meter so that both hubs are against the connection washers and run theconnection nuts down hand tight.4. In an alternating fashion, tighten the nuts to the appropriate torque for the connectionsize.5. Prior to turning on the gas in a new installation, check the meter's downstream system toensure that all connections are leak free or that the downstream valve, if one is present,is closed.Note: It is well worth the time checking connections to avoid an inadvertent anddangerous gas stream in the atmosphere.6. Open the upstream and downstream valves very slowly to prevent any pressure surgesinto or out of the meter.Caution: Avoid high differential pressure across the meter. Abnormal differentialpressures can damage internal meter components.7. Crack each valve open for a few seconds and then slowly-over a period of 10 seconds (¼PSIG systems)-turn the valve to the ¼ open position and then to the full open position.Caution: It is a good practice to pressurize the meter with the inlet valve so themeter runs forward. Locked off gas in a downstream section of a high pressuresystem could damage a meter with a reverse stop if the outlet valve from themeter is opened first.8. After the meter is pressurized, apply a soap solution or other good leak detecting liquid tothe connections to check for leaks.The Intelis meter capacity and pressure loss testThe Intelis meter capacity and pressure loss test confirms the meter's operating capacity.Installing the Intelis MeterOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 12Proprietary and Confidential
Chapter 4 Proving and Calibrating the IntelisMeterThis section provides information about the Intelis meter proving, testing, and calibratingprocess.Warning: Follow your company's standard operating procedures regarding the useof personal protection equipment (PPE). Adhere to guidelines issued by yourcompany in addition to those contained in this document when proving meters.The Intelis meter Test Mode and a proving station are used to confirm the calibration andaccuracy of the meter.Note: Test Mode is used in a meter shop or by a regulatory body. Some meter configurationis required for the meter to communication with the prover type.Proving the Intelis meter requires attaching the prover cable between the meter and theproving station. After the accuracy of the meter is confirmed or calibration is complete, theproving cable is removed and the meter returns to normal operation.Note: Temper meters unpackaged and uncapped in the proving area for 24 hours prior tothe testing. Some configuration of the meter is necessary for the prover station type. Thisconfiguration is completed using the FDM configuration file.Proving accessory Itron part numberIntelis prover cable CFG-7100-001Prover typesThere are a variety of prover types that can be used to prove the Intelis meter. Two interfaceoptions are shown in the following illustrations. For your specific prover, see thedocumentation for your prover type.OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 13Proprietary and Confidential
Proving operationsProving the Intelis meter involves the following tasks.1. Configuring Test Mode.2. Entering Test Mode.3. Recording prover consumption.4. Exiting Test Mode.5. Adjusting the calibration.Configuring Test ModeTest Mode configuration is completed using Field Deployment Manager (FDM) in one of twoways.• By loading the meter configuration from the FDM server using FDM mobile client.• By entering the parameters directly into the FDM mobile client which are then sent to themeter.The FDM configuration file must contain the listed information to complete the Test Modeconfiguration. After the meter receives the proper Test Mode configuration parameters, FDMis used to perform a Get of the attributes to display the value types.1. Set the pulse weight.2. Set the pulse width.3. Set the Test Mode maximum time.Entering Test ModeEntering Test Mode is accomplished using either the FDM mobile client or through themagnet in the head of the prover cable. The default is for the Intelis meter to enter TestMode after the prover cable pick up head magnet is detected. After the Intelis moves to TestMode, the following steps occur.1. The Intelis logs an Entering Test Mode event.2. The Intelis enters Test Mode.Caution: If the meter is operating in prover mode with a flow rate greater than 3.6CCF (360 cf) per hour with a pulse weight of 0.1 cf (the firmware default setting)and a pulse width of 1000 ms, the pulse output will always be high. This isbecause the meter is outputting a pulse every 1 second and the pulse width isalso 1 second. As the pulse weight is decreased and the pulse width is increased,the meter moves to 100% duty cycle. Reprove the meter by beginning with aQreal setting of 360 cfh (10194.064 Iph) and the pulse width set at 1000 ms.Measure the pulse output.3. The Intelis meter index is reset to a zero reading.4. The Intelis meter starts an optical pulse output.Proving and Calibrating the Intelis MeterOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 14Proprietary and Confidential
5. The Intelis meter LCD moves to Test Display Mode.Note: When the Intelis meter is in Test Display Mode, FDM can be used to confirm themeter is in Test Mode.Recording prover consumptionWhile the Intelis meter is in Test Mode, the listed operations occur.1. The Intelis meter records the Test Mode consumption in the index registers.2. The Intelis meter continues to output an optical pulse.Note: While the Intelis is in Test Mode, the LCD refresh rate is more frequent than whenthe meter is operating in Normal Mode.3. The Intelis meter continues to update the normal volume registers.Exiting Test ModeThe Intelis meter exits Test Mode after it receives a command from the FDM mobile client,after the proving cable head is removed from the meter, or when the Test Mode timeout isreached. The following operations occur when the Intelis exits Test Mode.1. The Intelis meter logs an Exiting Test Mode event.2. The Intelis meter ends the optical pulse output.3. The Intelis meter LCD returns to normal display mode.Note: Perform a Get to verify the Intelis meter is no longer in Test Mode.Adjusting the Intelis meter calibrationAdjusting the Intelis meter begins when FDM sends the FDM configuration file that containsthe parameters used by the Intelis to calculate correction factors for the flow rates.Note: The FDM configuration file values are not the correction factors but parameters thatare the result of the Test Mode ran in the utility meter shop.The FDM configuration file initiates the following calibration operations.1. The Intelis meter enters a Calibration in Progress state.2. The Intelis meter calculates correction factors for the assigned flow rate to meet thecalibration parameters.3. The Intelis meter sends the correction factors to the internal measurement device whichthen, calibrates itself.4. The Intelis meter logs a Meter Calibrated event.5. The Intelis meter moves to a Calibration Not in Progress state.Note: Perform a Get to confirm the status of the calibration process.Proving and Calibrating the Intelis MeterOpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 15Proprietary and Confidential
Chapter 5 OpenWay Riva Intelis Gas MeterMaintenanceThis section describes maintenance to keep the OpenWay Riva Intelis Gas Meter operatingat optimum performance.OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 16Proprietary and Confidential

Navigation menu