Itron NIC45 Dual band radio User Manual Understanding Silver Spring Networks Access Points
Silver Spring Networks Dual band radio Understanding Silver Spring Networks Access Points
Itron >
User Manual
Understanding Silver Spring Networks Access Points Silver Spring Networks 555 Broadway Street Redwood City, CA 94063 www.silverspringnet.com Understanding Silver Spring Networks Access Points Copyright © 2013 Silver Spring Networks, Inc. All rights reserved. The Silver Spring Networks logo, UtilityIQ®, and UtilOS® are registered trademarks of Silver Spring Networks, Inc. GridScape™, CustomerIQ™, and Direct-to-Grid™ are trademarks of Silver Spring Networks, Inc. All other company and product names are used for identification purposes only and may be registered trademarks, trademarks, or service marks of their respective owners. Please consider the environment before printing this document. Revisions Number Date Revision January 2013 Updated NIC 40 references to NIC 45, data rate for 900-MHz communications in Table 1, information in the sample FCC ID label, and changed references to DRM to HCM. December 2012 Added FCC and Government Guidelines section, revised EU regulatory information. Added 2.4 GHz to Specifications. Updated standards compliance specifications and corrected voltage range information. 10 Aug 2012 Updated supported frequencies for Luxembourg, United Kingdom, Portugal, and New Zealand; added EU regulatory information. Customer Support Country Email Telephone Hours Australia aus-support@silverspringnet.com 1300 706 769 9:00 AM - 9:00 PM Australia Eastern Time Canada support@silverspringnet.com Toll free: 5:00 AM - 6:00 PM 1-888-SSN-9876 US Pacific Time United States (1-888-776-9876) Worldwide Contact us on the Web +1-650-298-4298 http://www.silverspringnet.com/services/customer-support.html Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 2 Understanding Silver Spring Networks Access Points Contents Contents 1. About Access Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 AP Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Battery Backups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Read Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Rebooting or Recycling APs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Cellular Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Addressing Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 European Union Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Maintenance Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Redundant WAN Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 WAN Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Throughput Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Responding to a WAN Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Multicast / Unicast Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Networking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Address Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Administration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2. FCC and Government Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 FCC Guidelines for Devices Containing a Transmitter Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 External Antenna Integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 General Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Personal Protective Equipment (PPE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Fall Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Shock Accident First Aid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 3 Understanding Silver Spring Networks Access Points 1 About Access Points About Access Points Overview The Silver Spring Access Point (AP) provides the central link between endpoint devices and network control and monitoring. It is the connectivity between intelligent endpoints and the utility’s back office. Its flexible communication features extend the reach and coverage of the network to thousands of customer premises, through scalability that lowers ownership costs. Since it has a backup battery, the AP can reliably route scheduled read and management tasks, even during an outage. Figure 1 illustrates how APs connect endpoints to the utility back office (UtilityIQ data centers). Figure 1. The AP in the network The Access Point can be mounted on power poles or street lamps. All outbound communications (requests for data) pass through the AP. All inbound data packets (data, alarms) pass through the AP. The AP can serve as the take-out point for network management traffic in a stand-alone communication network (or also for Advanced Metering Infrastructure—AMI, Distribution Automation—DA, or HAN Communications Manager (HCM)—HCM traffic in a joint AMI/DA/HCM installation). In certain cases, the AP can be the take-out point for traffic. It is worth noting that the Silver Spring architecture differs from most others in that the AP is not what utility companies typically call a collector or concentrator—it is a router. This means that memory limits and data vulnerability issues typical of “collector” architecture are eliminated resulting in a more robust, scalable, simpler and higher performance network. The Access Point comes with a 902-928 MHz-based radio Neighborhood Area Network (or NAN) interface which can be configured with any cellular technology (for example, Code Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 4 Understanding Silver Spring Networks Access Points 1 About Access Points Division Multiple Access, Long Term Evolution, High Speed Packet Access, single carrier Radio Transmission Technology) Wide Area Network (WAN) interface, or with a 10/100 Ethernet interface. The Access Point provides a method for implementing the last mile utility information and control network. Features The features of the Silver Spring Access Point are: • Full two-way, 870-876 and 902-928 MHz FHSS • One-watt transmitter • Dynamic network discovery and self healing • Robust security from the endpoint through to the wide area network • “Over-the-air” network firmware upgrades • Sophisticated routing functions ensure multiple paths to each endpoint • Automated scheduling and network management tasks • Long-reach, multi-hop networks, providing high endpoint-to-Access Point deployment ratios • Weather-resistant outdoor enclosure, for longer life and greater durability • Battery backup option (highly recommended) for fault-tolerant operation AP Product Description The types of APs available are: Cellular APs, Satellite APs, Pad-mount APs, and Ethernet APs. The Ethernet APs can be configured with 10/100BaseT, and Fiber interfaces. Cellular and Ethernet Access Points are shipped pre-configured. For cellular Access Points, Silver Spring will work with the chosen cellular provider to facilitate Access Point turn-up. For Ethernet Access Points, Silver Spring will work with the client on IP addressing to allow Silver Spring to pre-configure field devices for quick field implementation. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 5 Understanding Silver Spring Networks Access Points 1 About Access Points Figure 2 shows an Ethernet AP. Figure 2. Silver Spring Networks Access Point (AP) Cellular antenna Power connector NAN antenna Battery Backups APs can be configured with battery backups. In the event of a power failure, the battery backup can provide continuous operation for at least eight hours. Silver Spring Networks suggests as a best practice, a battery backup within the Access Point. When operating on battery backup, Access Points maintain full operational features. The Infrastructure Battery Pack (IBP) uses sealed lead-acid battery technology, which will deliver energy over a -40 to +85C temperature range. Silver Spring operates the Infrastructure Battery Pack on a float (that is, the usage model is defined as long periods of topped-off charge states followed by sporadic deep discharge events (outage events). UtilityIQ®, GridScape, or HCM applications can actively monitor status. Events range in severity from informational (for example, export job succeeded) to warning (for example, the gap filler has started running because an interval gap was detected), to error (for example, the DC Detection flag on the meter was set), to emergency. These include an alarm when the backup battery on an Access Point is critically low. For more information on battery backup devices, refer to www.enersys.com. The key documents are: • Cyclon Application Manual • Cyclon Selection Guide Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 6 Understanding Silver Spring Networks Access Points 1 About Access Points The design float life of Silver Spring-IBP products is up to eight (8) to ten (10) years at room temperature (25°C/77°F) and under proper charging conditions. This design life has been confirmed by the use of accelerated testing methods that are widely accepted by both manufacturers and users of sealed-lead batteries. High temperatures are used to accelerate the aging process of the battery under test. Read Storage The Access Point has 8MB of RAM and 8MB of Flash. No reads are stored within the Access Point. Power Requirements The Access Point and Relay require 96 to 250 VAC (50 to 60 Hz). Power can be tapped directly from the power line or from a street light receptacle. Rebooting or Recycling APs Silver Spring Networks APs will run steady state for an indefinite period of time. Reboots are not contingent upon any inherent tendency for the AP to reboot itself. The only conditions that would manifest a reboot are: • Power failure in the absence of battery backup • WAN dialer reaches a “high water count” that induces a firmware reboot – this happens when cellular coverage is intermittent • Upgrade of firmware • Deliberate reboot instruction issued from field technician or from back-office Standards Compliance APs comply with: • Operating Vibration standard ANSI C12.20, IEC 60068-2-8 • Operating Shock standard ANSI C12.20, IEC 60068-2-27 • Humidity standard ANSI C12.20, IEC 60068-2-6 • Operating Temperature standard ANSI C12.20, IEC 60068-2-1, IEC 60068-2-2 • Electromagnetic Susceptibility standard ANSI C12.20, IEC 61000-4-3 • Surge Withstand Capability standard ANSI C12.20, IEC 61000-4-5 • Electrostatic Discharge standard ANSI C12.20, IEC 61000-4-2 • Electrical Fast Transients per ANSI C12.20, IEC 61000-4-4 • Conducted Immunity per IEC 61000-4-6 • Magnetic Immunity IEC 61000-4-8 • Voltage Dips & Interrupts IEC 61000-4-11 • Safety Standard for Information Technology Equipment, IEC 60950-1, IEC 60950-22 Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 7 Understanding Silver Spring Networks Access Points 1 About Access Points Cellular Modem Currently, the modem is a Sierra Wireless AirLink, RavenX, RavenXT, or RavenXE depending on AP model and country location. Addressing Schemes Silver Spring’s addressing scheme is based on the Internet Protocol (IP) suite. Each network device has one or more IPv6 addresses within the LAN. The Access Point will typically have an IPv4 address assigned to the WAN side. A 6in4 tunnel carries the data over a cellular carrier or Ethernet-based backhaul to the head end, where the tunnel is terminated, and IPv6 traffic is carried through to UtilityIQ, GridScape, or HCM. A high-level conceptualization of the NAN-to-WAN networks that AP traffic traverses is shown in Figure 3. Figure 3. APs in the Silver Spring Network The Access Point is the central link between the utility’s enterprise management systems and the endpoint devices such as Silver Spring-enabled electricity, water, gas meters, bridges, External Communications Modules, and Fault Circuit Indicators. The Access Point is a vital part of the smart grid network, which extends secure, real-time measurement and control interfaces (with full, two-way communications) throughout the network and to the customer premises. The Access Point provides a highly reliable connection to RF devices over a NAN. It communicates with intelligent endpoints, including meters and Bridges. The Access Point can also pass information through multiple Silver Spring Relays or through Silver Spring enabled electricity meters or Master Bridges. And it offers multiple paths to each endpoint, through sophisticated mesh network routing that ensures greater reliability and redundancy. The Access Point also provides WAN connectivity to your utility’s mission-critical applications through digital cellular or Ethernet connections. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 8 Understanding Silver Spring Networks Access Points 1 About Access Points Specifications The AP hardware specifications are listed in Table 1. Table 1. Access Point specifications Feature Description 900-MHz Communications: Data rate 100 - 300 Kbps Frequencies 902-928 MHz North America 915-928 MHz Australia 902-907.5, 915-928 MHz Brazil 870-876 MHz Luxembourg & United Kingdom 870-873 MHz Portugal 922-928 MHz New Zealand Spread Spectrum technology FHSS Transmitter output 30 dBm Output impedance 50 ohms Receiver sensitivity -97 dBm for 1% PER WAN Cellular, Ethernet, Satellite 2.4-GHz HAN Transceiver: Frequency range 2.4 GHz, ISM Band Data rate 100Kbps - 1Mbps FHSS Spreading technique FHSS Transmitter output Output Power: 20-27dBm FHSS Receiver sensitivity -97 dBm for 1% PER Power Draw TX 1.8 W typ. (2.0 W max.) Physical Interfaces: Antenna connector N Type, Female NAN antenna Omni antenna with gain not to exceed 3.6dBi on 2.4GHz and 3.0dBi on 900MHz Cellular antenna Mobile Mark antenna RMM-UMB-1S-WHT-7 Protocols/Security: Addressing Internet Protocol Version 6 (IPv6) Security Secure Hash Algorithm 256 bit (SHA-256) RSA-1024 and /or ECC256 Encryption AES-128 or AES-256 Mechanical: Cellular 24cm (9.5”) L x 25cm (10”) W x 13cm (5.2”) H, 2.38kg (5.1 lbs.) weight, IP65, white, aluminum housing Ethernet 23cm (9”) L x 20cm (8”) W x 10cm (4”) H, 1.8kg (4 lbs.) weight, IP65, white, aluminum housing Underground (cellular) 34cm (13.5”) L x 29cm (11.5”) W x 15cm (6”) H, 6.2kg (13.6 lbs.) weight, IP67, fiberglass reinforced polyester (FRP) housing Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 9 Understanding Silver Spring Networks Access Points 1 About Access Points Table 1. Access Point specifications (Continued) Feature Description Environmental: Operating Temperature: -40°C to +70°C (-40°F to +158°F) Humidity: 0% to 95%, non-condensing Power Voltage Range: 96 to 250 VAC, ~ 1A, 50 to 60Hz Power Consumption Ethernet Ethernet with battery Cellular Cellular with battery Idle Maximum 2.5W, 7W 2.5W, 8W 2.5W, 12.5W 2.5W, 13.5W Battery Backup Option: > 8 hour operation Receive Sensitivity Receive sensitivity is -102 dBm @ 10-6 BER. Mounting Kit Options: Pole Wooden, concrete, light Other Wall, pad Approvals: FCC Part 15.247 Industry Canada RSS-210 European Union Compliance This section describes Silver Spring Networks’ compliance with the EU R&TTE Directive. The Access Point 1.5i uses a one Watt FHSS radio. Licenses have been issued as follows: • Luxembourg A license has been obtained from ILR (Institut Luxembourgeois de Regulation) to operate in Luxembourg in the 870-876 MHz band. • United Kingdom A license has been obtained from Ofcom to operate in UK in the 870-876 MHz band. • Portugal A license has been obtained from ANACOM to operate in Portugal in the 870-873 MHz band. This device has been designed to operate with and certified for antennas that have a maximum gain of 3.0dBi on 900MHz and 3.6dBi on 2.4GHz. Antennas that have a gain greater than specified are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Installation of all antenna radiating elements shall have a minimum separation distance of 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 10 Understanding Silver Spring Networks Access Points 1 About Access Points Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC This declaration is only valid for configurations (combinations of software, firmware, and hardware) provided and supported by Silver Spring Networks Inc. The use of software or firmware not provided and supported by Silver Spring Networks Inc. may result in the equipment no longer being compliant with the regulatory requirements. Note: The equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The following standards were applied: • EMC: EN 55022 (2010), EN 55024(2010), EN 61000-3-2 (2006) EN 61000-3-3 (2008), ETSI EN 301 489-3 v1.4.1 • Safety: EN 60950-1:2006, EN 60950-22:2006, BS-EN 62311 (2008) • Radio: ETSI EN 300 220-1 v2.3.1 (2010-02), ETSI EN 300 220-2 v2.3.1 (2009-12), The conformity assessment procedure referred to in Article 10 and detailed in Annex IV of Directive 1999/5/EC has been followed. Note: This equipment is intended to be used in Luxembourg, United Kingdom, and Portugal in conjunction with licenses. For more details, contact Silver Spring Networks Compliance. The product carries the CE Mark: A copy of the Declaration of Conformity may be obtained with formal request to: Silver Spring Networks, c/o Hardware Engineering 555 Broadway Street Redwood City, CA 94063, USA Declaration of Conformity for RF Exposure This system has been evaluated for RF exposure for Humans in reference to EN 62311(2008) Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz). The minimum separation distance from the antenna to general bystander is 20cm (7.9 inches). Installation Note Since APs do not have a power on/off switch for disconnecting AC power before servicing, AC power is provided through an AC mains disconnect switch or breaker. Therefore, the electrical installation of this product is under the control of the power utilities or their authorized subcontractors. Refer to their procedures for further instructions. Only certain types of batteries can be used for battery replacements. Contact Silver Spring Networks for information about equivalent battery types that can be used for replacement. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 11 Understanding Silver Spring Networks Access Points 1 About Access Points Maintenance Procedures If an Access Point experiences an outage, all end point devices and Relays that were associated with it will converge on their secondary Access Point as found within their NodeQs. This alleviates outages due to Access Point failure. UtilityIQ-Network Element Manager (NEM), GridScape, or HCM is then alerted of an Access Point outage, and forwards this message to the operator. Spare pre-configured Access Points are kept on hand, and are scheduled for network insertion within the utilities work order management system. Within NEM, GridScape, or HCM, the failed Access Point is flagged for RMA, and the device is replaced. Surge Protection APs comply with up to 20kV for combination wave and up to 6kV for ring waves (reflects the current Ethernet AP and projected assembly.) Redundant WAN Option WAN redundancy is inherent to the routed Mesh being offered by Silver Spring Networks. Access Points have the ability to identify WAN outages and forward traffic to secondary Access Points through their 902-928 FHSS interface. There is no downtime realized and as routes to the WAN become unavailable, those routes age out of the route tables of adjacent nodes as would be expected in a full-mesh network that continuously updates node queues and route tables. When an AP becomes unavailable, the routed Mesh dynamically reconfigures to available APs. When the AP comes back online, the routed Mesh dynamically reconfigures to include the AP in the Mesh network. It is the suggestion of Silver Spring that multiple cellular carriers be spread across the territory to reduce the impact of a wide scale cellular outage. In addition, the co-mingling of private backhaul such as private network found within substations is also an option. The Silver Spring Networks Access Point can use public or private backhaul technologies to communicate to the host system (UtilityIQ, GridScape, or HCM) at the Utility head end. An AP can have a cellular modem (such as those approved for use on CDMA or General Packet Radio Service (GPRS) systems from Sprint, AT&T, Telus or other carrier) or any broadband technology that is Ethernet/IP compatible (such as Wi-Fi, fiber, private microwave or WiMAX). Current Silver Spiring customers are using cellular modems, fiber backhaul, and private licensed and unlicensed wireless backhaul technologies. Additionally, some customers are currently experimenting with satellite backhaul connections and will be deploying this technology where needed. Mounting Options The Access Points can be mounted on a utility pole or light pole. The can be pad mounted as well as wall mounted. (For additional information, refer to the Silver Spring Networks Infrastructure Hardware Guide.) Silver Spring recommends that the units be mounted at a height of 7 to 9 meters. WAN Options Any WAN backhaul that can interface with the Access Point’s Ethernet port and provide IPv4 connectivity to the HES with a minimum of 40kbps can be used as backhaul. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 12 Understanding Silver Spring Networks Access Points 1 About Access Points Customers have used the following alternative backhaul technologies: • Distribution Substation Backhaul (for example, fiber) • WiMAX • Satellite Radios The design rule for Access Point to RF devices is 1 to 5,000. At this ratio, the maximum data throughput required from a WAN solution is 40kbps per Access Point. Based on real-world data on a network of this size, the average wireless speed is measured at 2.6Mbps downstream and 700Kbps upstream, which is well in excess of requirements. The backhaul is fairly insensitive to latency (that is, in remote locations, Silver Spring already proven successful connection using satellite radios which have a ~1.5s RTT - or Round Trip Time). Silver Spring recommends that the network design for a particular deployment limit exposure to single points of failure and proactively design for redundancy by allowing each RF device to be reached from more than one Access Point. In all but rural densities, having up to 5,000 RF devices per AP generally results in most RF devices being able to reach more than one Access Point. Throughput Performance Typical data packet sizes observed in Smart Grid systems is between 150 bytes for DA or other simple command and control applications. A normal HCM and AMI meter read packet is approximately 350 bytes including full measurement intervals, event logs, and instantaneous register reads. At 100 Kbps (10 bytes / ms), delivery of 150 byte packets occurs at 10 full transactions per second. The larger AMI/HCM packets are delivered at 3-5 transactions per second. These are typical observed rates and it should be mentioned that for reliability reasons all transactions are completely acknowledged four-way confirmed events. Though final data is not available, raising on-air data rates from 100 Kbps to 300 Kbps will roughly double the PPS rates at the aggregation points (Access Points). This moves the daily capacity of an Access Point from approximately 400,000 transactions per day to nearly a million. The bandwidth being fed to the WAN side of the Access Point is determined by what backhaul is being used. With the Access Point being a router and not a collector, data is constantly being transmitted through the WAN, eliminating the need to store data for later transmission (Store and Forward). The Access Point, using 100Kbps on the NAN side, aggregates 3000-5000 meters, bridges, or other RF devices, while processing approximately 5 transactions per second and delivering upwards of 500,000 transactions per day to the back office. The raw throughput in the RF NAN in the Silver Spring smart grid solution is 100 Kbps node-to-node. This means that between each device, there is 100 Kbps of available bandwidth. On average, the amount of traffic is relatively low with respect to the amount of available bandwidth. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 13 Understanding Silver Spring Networks Access Points 1 About Access Points Figure 4 illustrates data collected from a live customer network over a period of one week. As shown, the average bandwidth consumed by Advanced Metering traffic is approximately 15 Kbps or 15%, leaving 85% for other smart grid solutions such as DA or DR (disaster recovery). Figure 4. Average bandwidth consumed by AMI traffic It is worth noting that there are a number of factors that impact each RF Mesh link between any two nodes including but not limited to: scheduled jobs (such as meter reads), path selection from an RF device to an Access Point, failures or outages, etc. An effective method to monitor network performance (data transmission, bandwidth utilization, etc.) is at an Access Point as the AP is the take out point for all associated RF devices. Meaning RF devices and Relays in the Silver Spring NAN are constantly retuning to, optimizing their paths and reporting into their Access Points. All traffic flowing in and out of the RF Mesh network must traverse the Access Point. While it is fairly simple to monitor a single Access Point, it is important to realize that there are typically many Access Points in a commercially deployed smart grid system. The Silver Spring solution enables all Access Points to operate independently and in parallel, effectively increasing throughput and reducing latency. The Silver Spring UtilityIQ NEM, GridScape, and HCM enable the configuration of polices for bandwidth utilization for both the WAN and the NAN. Once configured, the monitoring applications generate alerts for any bandwidth utilization policy violations. The network statistics report provides detailed insight into potential network load issues. The monitoring applications can measure and report on RF characteristics in the NAN, including the identification of devices associated with areas of poor coverage. Having such data enables Silver Spring to assess whether such areas require the deployment of additional Relays or Access Points. This is especially useful in the early phases of a deployment. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 14 Understanding Silver Spring Networks Access Points 1 About Access Points Figure 5. AP Failure management Alert Recieved Alert Cleared ? Yes Stop No Yes Problem with Event Monitoring – Call IT No Ping the IPv6 Address of the AP IPv6 reachable ? Alert Cleared ? Yes Problem with AP Hardware – Call Field Engineer No Ping the IPv4 Address of the AP IPv4 reachable ? B /D O AP ? Yes Yes Use Wireless ACE utility to isolate Problem AP 6in4 No 10 Traceroute to the IPv4 Address of the AP 11 Traceroute terminates inside L42 ? Yes Problem with BO Network – Call IT 13 IPv4 reachable ? Yes Problem with BO Network – Call IT Problem with 6in4 tunnel – Call IT No 12 From a remote server ping the IPv4 address of AP No 14 Identify Neighbouring Devices 16 AP Seen in neighbour NodeQ? 15 Check NodeQ of neighbours Yes 17 Is reboot counter increasing ? 18 Attempt to reboot Manually Yes No Yes 20 Carrier Network OK Problem with WAN Network – Call WAN Carrier 19 Manual reboot resolve? No Yes Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Problem with AP Hardware – Call Field Engineer Problem with AP Hardware – Call Field Engineer Problem with WAN Network – Wait for resolution No Problem with AP Hardware – Call Field Engineer Stop Silver Spring Networks 15 Understanding Silver Spring Networks Access Points 1 About Access Points Responding to a WAN Failure An AP might not be reachable because the device cannot dial out on the WAN. The device continues to try dialing out until it is either able to connect, or it has dialed 308 times. If it can connect, the device notifies the event management program that it has successfully recovered. If it cannot, then the modem resets itself. The behavior of an AP repeatedly becoming unreachable, and then recovering shortly after, is called flapping. A small amount of flapping is normal. Because a device can recover on its own, wait for one day of downtime, or one to two days of frequent flapping before investigating further. Filtering and reviewing the event management program mail alerts regularly can help to identify devices that need attention. The standard operating procedure regarding collector failure/management is shown in Figure 5 on page 15. Multicast / Unicast Communications Commands sent from head-end monitoring applications (NEM, GridScape, or HCM) through the Access Point (AP) are unicast, as the receipt of each packet must be acknowledged. However, in similar fashion to multicast, commands can be sent to a statically or dynamically defined group of RF devices for ease of manageability. In addition, the HES sends “Jobs” out in parallel to Access Points, that then in turn, send commands out to endpoints. The resulting effect is parallel processing that accomplishes a multicast-like service. Networking Each NIC in Silver Spring RF devices registers with two IPv6 addresses – one for each of two APs: a primary and secondary AP. When one dies, another is found. From a topology perspective, each AP is its own IPv6 subnet. So NICs are in two different subnets - one for each AP. The end-to-end protocol within the NAN is AES 128/256 bit, crypto IPv6. As the Access Point understands the full topology of the underlying mesh, the IPv6 packet is source routed from the AP to each end device – meaning that the full communication path from the Access Point to the device is specified, hop by hop, in the packet. The NAN endpoint to Access Point routing decisions are made hop-by-hop (that is, the NAN endpoint will send the IPv6 packet to its neighbor that has the least cost route to the Access Point. Then this neighbor will forward the packet to its neighbor with the best route until the packet reaches the Access Point. (The Access Point acquires its understanding of the full mesh topology because it sends route advertisement messages at randomized intervals.) NAN system one way latency is measured at 50ms per hop between any points in the NAN. The Silver Spring network design expects on average, no more than 6 hops to any end point (such as a meter or Data Link Control, DLC, device). This would typically yield 300ms of NAN latency to any RF or DLC device. In addition, an Access Point can process up to 10 packets per second. Each DLC command consists of a single packet, with one associated ACK packet. With no other AMI traffic traversing an Access Point, an Access Point could process 100 DLC commands and ACKs, in approximately 30 seconds. The cellular modem has store-and-forward GPS reporting capability with accuracy no less than 10 meters. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 16 Understanding Silver Spring Networks Access Points 1 About Access Points Address Management For the LAN, a DDNS (Dynamic DNS) system is used. Each device has one or more IPv6 addressed assigned to it, based on its location in the network and route out of the LAN. These addresses are then stored at the head end and used for all communications with the devices (ping, trace, reads, etc.), giving the customer a true, native end-to-end IP network. Administration This section discusses administrative issues about Access Points. The RavenX modem in each AP has a TELNET port that is used for internal communications support purposes. The RavenX modem on the AP uses port 6543 for TELNET. Do not disable this port as doing so will prevent the Sierra Wireless application from communicating. Note: Silver Spring does not support end users accessing the AP’s modem TELNET port. Just like a meter, it is possible to ping an Access Point. The Silver Spring solution uses IPv6, so it is simply a matter of invoking an on-demand ping. This can be accomplished through the UtilityIQ-AMM user interface, through web services, through GridScape, or through HCM. You should get two ping responses for each AP. One is from the RavenX modem. The other is from the NIC in the AP. To invoke an on-demand ping against an Access Point, navigate to the appropriate Device Details page and click on the On Demand Ping link (location varies with each monitor application). Figure 6 illustrates the ping sequence for UtilityIQ’s AMM application. Figure 6. Ping sequence Also, UtilityIQ AMM exposes a web services API for invoking on-demand pings against Access Points. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 17 Understanding Silver Spring Networks Access Points 1 About Access Points Configuration To facilitate the configuration and remove the chance for human error (for example, typos) a simple shell script is generated and run from a Unix-based laptop which has a Silver Spring Field Service Unit attached to the USB port. All Silver Spring APs are configured during the manufacturing process to ensure that the proper profile (Network ID, etc.) is included. Additionally, the software tool, net_mgr, required to configure an AP, is not a user facing tool. Note: Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 18 Understanding Silver Spring Networks Access Points 2 FCC and Government Guidelines FCC and Government Guidelines Silver Spring Networks NIC FCC ID: OWS-NIC45 IC: 5975A-NIC45 M/N: NIC45 The AP/Relay NIC is REQUIRED to be professionally installed by a properly trained technician. Improper installation could void the userʹs authority to operate the equipment. The device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. The device may not cause harmful interference. 2. The device must accept any interference received, including interference that may cause undesired operation. The antenna of this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The device should be installed so that people will not come within 20 cm (8 in.) of the antenna. This equipment has been tested and found to comply with Part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception (which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver disconnected. • Consult the dealer or an experienced radio/TV technician for help. Figure 7. Sample FCC ID label for NIC PCA Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 19 Understanding Silver Spring Networks Access Points 2 FCC and Government Guidelines CAUTION: Changes or modifications not expressly approved by Silver Spring Networks could void the user's authority to operate the equipment. FCC Guidelines for Devices Containing a Transmitter Module The following is an extract from FCC PART 15 UNLICENSED MODULAR TRANSMITTER APPROVAL, DA 00-1407, Released: June 26, 2000, Section 6 describing labeling requirements for devices containing a modular transmitter. Section 6. The modular transmitter must be labeled with its own FCC ID number, and, if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. Figure 8. Sample FCC ID label for devices containing a NIC Contains FCC ID: WWWXXXXX IC:YYYYY-XXXX M/N: ZZZZZ External Antenna Integration This radio transmitter 5975A-NIC45 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. • Antenne omnidirectionnelle, 3.0dBi sur 900 MHz et 2,4 GHz sur 3.6dBi Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle sʹil fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types dʹantenne énumérés ci-dessous et ayant un gain admissible maximal et lʹimpédance requise pour chaque type dʹantenne. Les types dʹantenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour lʹexploitation de lʹémetteur. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 20 Understanding Silver Spring Networks Access Points 2 FCC and Government Guidelines Safety Information WARNING: Severe shock and explosion hazard! Touching energized parts can result in massive equipment damage, and severe injury or death. Short-circuiting energized parts will result in blinding flash and explosion. Opening and closing electrical circuits can also produce dangerous and explosive arc flashes. Involuntary muscular reactions associated with electrical shock may result in other injuries. Observe the following safety guidelines. Careful planning of every job is essential. Nothing should be taken for granted. Do not take chances! • Read and follow all approved policies and procedures provided by your employer associated with the procedures in this manual. • The procedures in this manual must only be performed by qualified workers in accordance with local utility safety practices, utility requirements, and applicable OSHA and NFPA standards. • The information contained in this document is intended to aid qualified personnel, and is not a replacement for the proper training required to make a person qualified. • Silver Spring Networks assumes no liability for the customerʹs failure to follow these safety guidelines. General Electrical Safety • Perform the procedures in this manual in accordance with applicable workplace standards established by the following agencies: — Occupational Safety and Health Act (OSHA). — The National Electrical Code published by the National Fire Protection Association (NFPA-70). — National Electrical Manufacturers Association (NEMA). — Electronics Industries Association (EIA). — Insulated Power Cable Engineers Association (IPCEA). • American National Standards Institute (ANSI). Whenever possible, de-energize all circuits or equipment before working on them. • Maintain a minimum clearance of 10 feet (3 meters) between line potential and all unqualified persons at all times. • Keep unauthorized people out of the work area. Be especially cautious of children, who tend to be drawn to work activity. • Determining if a circuit is OFF can be difficult in some instances. Check for circuit voltage with an appropriate voltmeter before working on equipment presumed to have been de-energized. Tiebreakers, double throw disconnect switches, automatic transfer switches and emergency generators can supply power through an alternate circuit or from another source. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 21 Understanding Silver Spring Networks Access Points 2 FCC and Government Guidelines • 120V current can be just a lethal as higher voltages because current flow through a body depends upon the bodyʹs resistance. • Do not trust insulation and/or weatherproofing on a wire as protection from shock. • Use electrically insulated tools. Inspect portable electrical equipment or tools for defects and remove any defective devices from service immediately. All portable electrical equipment must have Ground Fault Circuit Interrupter (GFCI) protection. • Select the right tool for the job. Use tools properly. Keep tools in good working order. • Make sure the work area is free of any flammable material. Flammable vapors can be ignited by an arc flash. • Keep the work area clean and dry. Cluttered work areas cause accidents and injuries. • Provide good lighting in the work area. You cannot work safely if you cannot see what you are doing. • Report unsafe conditions or defective equipment to your immediate supervisor. • Handle material carefully. Lift and carry properly. Personal Protective Equipment (PPE) • Always wear Personal Protective Equipment (PPE), in accordance with OSHA and ANSI standards. • Wear eye protection and electrically insulated gloves. Test gloves in accordance with ANSI standards before use. Do not use gloves that do not pass appropriate test procedures. • Wear protective clothing such as long sleeve shirts and long pants made of flame resistant materials. • Remove all jewelry. • Do not pass any objects to or from other persons not protected by insulating platforms or tested, electrically insulated gloves. Fall Protection When performing work at any elevation: • Always use a fall protection system, in accordance with OSHA standards, whenever performing work at any elevation. • Never use conductors, guy wires, pins, or cross-arm braces, etc. to support your weight. • Whenever using aerial lift devices such as hoists, man-lifts, vehicle-mounted work platforms and overhead lifts, read and follow the manufacturerʹs guidelines for safe and proper operation. • Use ladders and scaffolding only in accordance with the manufacturerʹs guidelines and/or according to OSHA standards. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 22 Understanding Silver Spring Networks Access Points 2 FCC and Government Guidelines • Only use ladders made of non-metallic, non-conductive material. They should be the proper size and type for the work intended. Inspect ladders for wear and breakage. Remove any oil, grease, or other slippery materials. • Do not set the ladder at too steep or too shallow of an angle. A rule of thumb is to stand erect with your toes against the bottom rails of the ladder, with your arms extended straight out. If you can set your palms on top of the rung that is at eye level, the ladder should be at the proper angle. If a ladder angle label is provided, follow its recommendations. • If the ladder is to remain in place for an extended period, secure it at the top. The support point at the top of the ladder should be at least 24 inches (60 centimeters) wide to maintain support in the event of sideways movement. For jobs of short duration, have a fellow worker support the ladder at the base. • Evaluate all tasks to be performed from a ladder for potential fall hazards, such as complex tasks or situations that require leaning from the side of the ladder. • The use of scaffolding or a work platform should be considered as an alternative solution in such cases. Shock Accident First Aid • Do not touch the victim with your bare hands; use something non-conductive to separate the victim from the energy source. • Call for emergency medical help immediately. Keep the victim lying down, warm, and comfortable until help arrives. Avoid moving the victim in case of injury to neck or back. Position an unconscious victim on a side to let fluids drain. • Check the victimʹs breathing and heartbeat. If properly trained, apply mouth-to-mouth resuscitation and/or CPR if necessary. • Remove constricting items from the victim, such as shoes, belts, jewelry, and tight collars; they could cut off circulation if the victim experiences swelling. • Apply water or saline for a few minutes to any burns until the skin returns to normal temperature. Do not attempt to remove clothing that is stuck to a burn. If possible, elevate burned areas to reduce swelling. • Make sure the victim receives professional medical attention, even if they feel fine. Electric shock can cause heart failure hours after the shock is received. Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 23 Understanding Silver Spring Networks Access Points Index Index Distribution Substation Backhaul 13 Access Point 5 DNS (Domain Name System) 17 Access Point 1.5i 10 address management 17 addressing 9 addressing scheme 8 ANACOM 10 ANSI C37.90.2 7 ANSI C12.2 7 ANSI C12.20 7 AP Access Point 5 administration 17 cellular 5 configuration 18 Ethernet 5 hardware specifications 9 pinging 17 rebooting 7 recycling 7 types 5 backhaul 8 battery backup 5, 6 BS-EN 62311 11 CE Mark 11 cellular AP 5 collector 4 concentrator 4 Conducted Immunity 7 data packet size 13 DDNS (Dynamic DNS) 17 Declaration of Conformity 11 Directive 1999/5/EC 11 Understanding Silver Spring Networks Access Points Rev 3 EC 60950-1 7 Electrical Fast Transients 7 electromagnetic susceptibility standard 7 electrostatic discharge standard 7 EMC standards 11 EN 300 220-1 v2.3.1 (2010-02) 11 300 220-2 v2.3.1 (2009-12) 11 55022 (2010) 11 55024(2010) 11 60950-22 2006 11 61000-3-2 (2006) 11 61000-3-3 (2008) 11 62311(2008) 11 encryption 9 Ethernet AP 5 ETSI EN 11 EU R&TTE Directive 10 FCC (Federal Communications Commission) 10 FHSS (Frequency Hopping, Spread Spectrum) 5 fiber 12 flapping 16 float 6 float life 7 GPRS (General Packet Radio Service) 12 GridScape 6 HAN Communications Manager (HCM) 4 hardware specifications 9 humidity 10 humidity standard 7 22 January 2013 Silver Spring Networks 24 Understanding Silver Spring Networks Access Points Index IBP (Infrastructure Battery Pack) 6 Ofcom 10 IEC 801.2 7 operating shock standard 7 IEC 60068-2-1 7 Operating Temperature standard 7 IEC 60068-2-2 7 operating vibration standard 7 operating temperature 10 IEC 60068-2-27 7 IEC 60068-2-6 7 IEC 60068-2-8 7 Part 15.247 10 IEC 60950-22 7 power connector 6 IEC 61000-4-11 7 power requirements 7 IEC 61000-4-2 7 IEC 61000-4-3 7 IEC 61000-4-4 7 IEC 61000-4-5 7 IEC 61000-4-6 7 IEC 61000-4-8 7 Industry Canada 10 Infrastructure 6 Institut Luxembourgeois de Regulation 10 intelligent endpoints 4 IP (Internet Protocol) 8 IPv4 address 8 Magnetic Immunity 7 maintenance 12 microwave 12 R&TTE Directive 1999/5/EC 11 radio standards 11 RavenX modem 17 receive sensitivity 10 redundant WAN 12 RF devices 8 RSS-210 10 Safety Standard for Information Technology Equipment 7 safety standards 11 Satellite radios 13 security 9 Sierra Wireless AirLink PinPoint X 8 mounting options 12 standards compliance ANSI C37.90.2 7 IEC 801.2 7 NEBS3 7 multicast 16 surge protection 12 Mobile data antenna 6 modem 8 mounting 4 NAN antenna 6 Neighborhood Area Network 4 NEBS 3 7 NIC 16 surge withstand capability standard 7 take-out point 4 TELNET port 17 Telus 12 tunnel 8 Understanding Silver Spring Networks Access Points Rev 3 22 January 2013 Silver Spring Networks 25 Understanding Silver Spring Networks Access Points Index unicast 16 WAN failures 16 options 12 Wide Area Network 5 UtilityIQ 6 Voltage Dips & Interrupts 7 voltage range 10 Understanding Silver Spring Networks Access Points Rev 3 Wi-Fi 12 WiMAX 12, 13 22 January 2013 Silver Spring Networks 26
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-701 Format : application/pdf Title : Understanding Silver Spring Networks Access Points Creator : Silver Spring Networks Create Date : 2013:01:22 15:04:11Z Creator Tool : FrameMaker 11.0 Modify Date : 2013:04:20 11:25:08-07:00 Metadata Date : 2013:04:20 11:25:08-07:00 Producer : Acrobat Distiller 10.1.5 (Windows) Document ID : uuid:837bf5ca-7a55-4e42-b68b-3c16a8ffb796 Instance ID : uuid:a17c75ec-a9e7-11e2-97da-040cce202c34 Page Count : 26 Page Layout : SinglePage Language : en Author : Silver Spring NetworksEXIF Metadata provided by EXIF.tools