JCM Technologies BASE5001B-2B Receiver for security gate system User Manual 1248017 GB BASE500 v1 2

JCM Technologies, S.A. Receiver for security gate system 1248017 GB BASE500 v1 2

User Manual

Download: JCM Technologies BASE5001B-2B Receiver for security gate system User Manual 1248017 GB BASE500 v1 2
Mirror Download [FCC.gov]JCM Technologies BASE5001B-2B Receiver for security gate system User Manual 1248017 GB BASE500 v1 2
Document ID1604621
Application IDhDdlx4pqRiGsvxTAZBu2Wg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize11.96kB (149495 bits)
Date Submitted2011-12-18 00:00:00
Date Available2011-12-18 00:00:00
Creation Date2011-12-13 09:52:01
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2011-12-13 09:52:01
Document TitleMicrosoft Word - 1248017-GB_BASE500_v1.2
Document CreatorPScript5.dll Version 5.2.2
Document Author: Gemma

COD. 1248017-GB / 1.2
BASE500
BASE500-1B / BASE500-2B
TECHNICAL CHARACTERISTICS
Frequency
Coding
Memory
Number of relays
Supply
Power supply range
Relay contacts
Standby/Op. consumption
Op. temperature
Watertightness
Size
Box dimensions
BASE500-1B / BASE500-2B
868,35MHz
High security rolling code
500 codes
1 / 2 relays
12/24V ac/dc
9-23 / 22-35V dc
8-16 / 16-27V ac
1A
60mA / 90mA
-20ºC to +85ºC
IP54 (with glands IP65)
63x74x25mm
82x190x40mm
COD. 1248017-GB / 1.2
BASE500
INSTALLATION AND CONNECTIONS
Attach the rear part of the housing to the wall using the plugs and screws supplied. Pass
the cables through the bottom of the receiver. Connect the power cables to the terminals
marked in the mother board, as indicated. Fix the receiver front to the rear part using the
screws supplied.
OPERATING
The pilot lights are activated every 5 seconds to indicate the correct supply of power to the
equipment. Upon receiving a code, the receiver checks whether it is in its memory,
activating the corresponding relay. The relay activation mode is selected in either impulse
or ON/OFF using the Imp/Bies jumper (only with the relay 2). For adjustment of relay 1,
see manual of the programming tool.
PROGRAMMING
MANUAL PROGRAMMING
Press the receiver programming button for 1 sec. and an acoustic signal will be heard. The
receiver will enter standard programming (see table). If the receiver programming button is
held pressed down, the receiver Hill enter special programming, cyclically passing from
one configuration to the next. Once the programming configuration for the transmitter to be
registered has been chosen, send the code to be programmed by pressing the transmitter.
Every time a transmitter is programmed, the receiver will issue an acoustic signal for 0.5
sec. After 10 seconds without programming or pressing the first two transmitter buttons,
the receiver will exit programming mode, issuing two acoustic signals of 1 sec. If upon
programming a transmitter the receiver memory is full, it will issue 7 acoustic signals of
0.5 sec. and exit programming.
Configuration of transmitter programming in the receiver.
Standard Programming (default option,
the receiver is always configured on pluri-channel)
The relays are activated 1st relay by channel 1
and 2nd relay by channel 2 (3rd relay by channel 1
and 4th relay by channel 2)
Special programming
Press the transmitter channel to activate the relay 1 on the receiver
Press the transmitter channel to activate the relay 2 on the receiver
Press the transmitter channel to activate the two relays at once *
•
Led R1
Flashing
ON
OFF
ON
Led R2
Flashing
OFF
ON
ON
If working in ON/OFF activation mode, relay 1 will act as impulse and relay 2 as
ON/OFF. Therefore, on the first press relay 1 will close and open the contact and
relay 2 will only close. On the second, relay 1 will close and open the contact and
relay 2 will open.
N.B.: Each transmitter can be configured independently on the receiver.
COD. 1248017-GB / 1.2
BASE500
TOTAL RESET
In programming mode, the programming button is held down and the “MR” reset jumper
is bridged for 3 secs. The receiver will issue 10 short acoustic warning signals followed by
others at a faster pace to indicate that the operation has been successful. The receiver is
now in programming mode.
After 10 seconds without programming or quickly pressing the programming button, the
receiver will exit programming mode, issuing two acoustic signals of 1 sec.
GROUPS
Receivers can be configured with a group (from 0 to 7) so that there is no interference
when working near each other.
125kHz
868MHz
C2- G1
G1
C1- G0
C2- G1
125kHz
C3- G1
C3- G1
125kHz
868MHz
C2- G2
G2
C2- G2
C2- G0
125kHz
C3- G2
C3- G2
C=channel
G=group
N.B. Group 0 enables all groups.
GROUP CONFIGURATION
The configuration can be carried out with the programming tool or by self-programming as
follows.
COD. 1248017-GB / 1.2
BASE500
Self-programming
After the receiver has been totally reset, it will be configured with the group of the first
radio-programmed transmitter by enabling the hands free mode.
Exception: If the receiver has been configured using programming tools, the group may
only be changed with the programming tool.
Operations
On powering the receiver, the led R1 will flash the same number of times as the group
number with which it is configured.
USE OF THE RECEIVER
These receivers are designed for use as remote controls for garage doors. Their use is not
guaranteed for directly activating any other equipment different to that specified.
The manufacturer reserves the right to modify equipment specifications without prior
notice.
IMPORTANT ANNEX
Disconnect the power supply before handing the unit.
In compliance with the European Directive low-voltage electrical equipment, we hereby
inform users of the following requirements:
· For units which are permanently connected, an easily accessible circuit-breaker device
must be built into the wiring system.
· This unit must always be installed in a vertical position and firmly fixed to the structure of
the building.
· This unit must only be handled by a specialised installer, by his maintenance staff or by a
duly trained operator.
· The instruction manual for this unit must always remain in the possession of the user.
· Terminals of maximum section 3,8mm2 must be used for the power supply connections.
· Use time delayed fuses.
Hereby, JCM TECHNOLOGIES, S.A., declares that this BASE500-1B, BASE5002B is in compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
To comply with FCC rules, adjustment or modifications of this receiver and/or transmitter
are prohibited, except for changing the code setting or replacing the battery. THERE ARE
NO OTHER USER SERVICEABLE PARTS. Any other changes made, not expressly
approved by JCM Technologies, S A could void the user’s authority to operate the
equipment.
CE DECLARATION OF CONFORMITY
See web www.jcm-tech.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2011:12:13 09:52:01+01:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2011:12:13 09:52:01+01:00
Format                          : application/pdf
Title                           : Microsoft Word - 1248017-GB_BASE500_v1.2
Creator                         : Gemma
Document ID                     : uuid:87b8b90f-0c30-4494-8d16-50ce2074277a
Instance ID                     : uuid:e08b09b0-8a60-4cb1-a7b0-a230c8f74632
Page Count                      : 4
Author                          : Gemma
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U5Z-BASE5001B-2B

Navigation menu