JCM Technologies RB3OSE916 Transceiver for Automatic Door Safety Edges User Manual

JCM Technologies, S.A. Transceiver for Automatic Door Safety Edges

User Manual

Download: JCM Technologies RB3OSE916 Transceiver for Automatic Door Safety Edges User Manual
Mirror Download [FCC.gov]JCM Technologies RB3OSE916 Transceiver for Automatic Door Safety Edges User Manual
Document ID2933175
Application IDZXfkrP7BF6Sfgw0Y5/3waQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.18kB (302258 bits)
Date Submitted2016-03-17 00:00:00
Date Available2016-03-17 00:00:00
Creation Date2015-09-18 09:06:35
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2015-09-18 09:06:38
Document TitleUser Manual
Document CreatorAcrobat PDFMaker 10.1 para Word
Document Author: Gemma

RB3 OSE916
User’s Manual
EN
Introduction
The RadioBand system is designed for Commercial and Domestic door applications where a safety edge is used. The system provides
a wireless system replacing spiral cables or energy chain systems to provide the safety signal to the door or gate control panel. The
receiver monitors the status of transmitters connected to it. When an obstacle is detected, the RadioBand system puts its output in a
safety state.
Up to three transmitters per output can be connected to the receiver. There are two outputs on each receiver that can be connected to
the control panel, one as OSE interface, and the second one is a normally close contact.
The system complies with EN ISO 13849-1:2008, category 2, PLd.
The manufacturer reserves the right to change the specification of the equipment without prior warning.
Technical data
Frequency
Memory
Power supply
Power supply range
Consumption standby/operating
Radiated power
Operating temperature
Seal
Box size
Range (in open field)
Reaction time (typical)
Maximum reaction time when
interferences
1248xxx_Rev0.0 RB3 OSE916
Multifrequency system 916 MHz auto-adjustable
6 transmitters (3 on output 1, 3 on output 2)
12/24V ac/dc
9-35V dc
8-28V ac
Max 255mA
< 25mW
-20ºC a +55ºC
IP65 – The glands have to be installed to ensure IP65.
82 x 190 x 40mm
50 m
35ms
220ms
Page 1/4
Connection
OSE 3 wire connection
OSE 2 wire connection
Starting up
Mechanical installation
Fix the back of the box to the wall, using the wall plugs and screws supplied. Install the receiver, close to the door and avoid metal
surfaces between the receiver and the transmitter. The transmitter and receiver antenna must be parallel to each other for optimum
signal reception. Pass the cables through the bottom of the receiver. Connect the power cables to the terminals of the printed circuit,
following the indications of the connections diagram. Store transmitters. Fix the front of the receiver to the back with the screws
supplied for the purpose.
Programming transmitter to receiver
The receiver allows programming 6 transmitters (3 for Relay 1 and 3 for Relay 2). Each safety edge transmitter must be learnt into the
appropriate channel of the safety edge receiver. A transmitter should only be connected to one receiver.
Press PROG button and keep pressed until desired mode selected.
Programming of one safety transmitter (IN1 input)
Mode
Configuration of transmitter programming in the receiver.
Safety edge activates relay 1 on the receiver
Safety edge activates relay 2 on the receiver
Safety edge activates the two relays 1 and 2 at the same time
Led R1
ON
OFF
ON
Led R2
OFF
ON
ON
Led R1
Flashing
Led R2
Flashing
Programming of two safety transmitters (IN1 and IN2 input)
Mode
Configuration of transmitter programming in the receiver.
Safety edge in IN1 activates relay 1 and safety edge in IN2 activates relay 2
1248xxx_Rev0.0 RB3 OSE916
Page 2/4
PRESS RPROG PUSHBUTTON
LED TURNS ON
PRESS TRANSMITTER PROG
PRESS RPROG PUSHBUTTON
LED TURNS OFF & END PROG
ONE BEEP & PROGRAMMED
Check the correct operation
Press each safety edge connected to assure that the appropriate relay on the receiver is activated.
If not, see the Leds and Beeps indication table, to check what is happening and how to solve it.
Maintenance
Leds and beeps indication table
R1/R2
Led
ON
Check
Led
OFF
Beeps
Equipment
Message / error
Solution
No beeps
RB3 T
Detection of the safety edge
OFF
OFF
RB3 R
RB3 R
Communication failure between RB3 R and RB3 T
RB3 T low battery
ON
OFF
RB3 R
RB3 T only one battery connected
Verify and connect the second battery.
OFF
ON
4 beeps
each 20
seconds
4 beeps
each 20
seconds
No beeps
Verify that the IN1/IN2 led of the RB3 T is at ON when
you press PROG button of RB3 T, to check the correct
operation.
Verify the radio signal with the Check function.
Verify the batteries of the transmitter
RB3 R
Check function. See coverage and signal quality table.
---
System Check
Press the receiver’s CHECK button for at least 1 second to enter check mode. The indicator light will come on and four beeps will be
heard.
Perform a complete door opening and closing manoeuvre. During the system check a beep will be heard every 1,5 seconds.
To exit Check mode, press the CHECK button or wait 5 minutes. On exiting check mode, seven consecutive beeps will be heard and
the indicator light will flash continuously.
If the communication fails, halt the door manoeuvre and press the safety edges installed to detect what has failed.
Perform another system check until the result is correct.
Press the safety edges
Three consecutive beeps
are heard
A single beep is heard
A single beep is heard
A single beep is heard
Nº flashes
check led
Signal coverage
Result of check
Very weak
Safety edge failure
Weak
Normal
Good
Very good
OK
OK
OK
OK
1248xxx_Rev0.0 RB3 OSE916
Solution
Change the orientation of the transmitting-receiving aerials.
The battery consumption will be higher
Page 3/4
Maintenance
Total reset
In programming mode, keep the programming PROG button pressed down and make a bridge with the “MR” reset jumper for 3s.
The receiver will emit 10 warning sound signals and then more at a faster frequency, indicating that the operation has been carried
out. The receiver will stay in programming mode.
If 10 seconds pass without programming a transmitter, the receiver will exit the programming mode, emitting two 1 sec beeps.
Replacing a transmitter
If a transmitter becomes damaged the whole system must be reset and replaced, and non-damaged transmitters must then be reprogrammed into the receiver.
Important Annex
Disconnect the power supply whenever you proceed to the installation or repair of the control panel.
In accordance with the European low voltage directive, you are informed of the following requirements:
· For permanently connected equipment, an easily accessible connection device must be incorporated into the cabling.
· This system must only be installed by a qualified person that has experience with automatic doors/gates and knowledge of the
relevant EU standards.
· The instructions for use of this equipment must always remain in the possession of the user.
· Terminals with a maximum section of 3.8mm2 must be used to connect the cables.
Follow all the recommendations given in this manual to avoid serious dangerous to persons.
Regulations
EC Declaration of conformity
See web www.jcm-tech.com/en/declarations/
JCM TECHNOLOGIES, S.A. declares herewith that the product RB3 OSE916 complies with the requirements of the 1999/5/ CEE
R&TTE Directive, and complies with the fundamental requirements of the 2006/42/CE Machine Directive, 2004/108/EC Directive
on electromagnetic compatibility and 2006/95/EC on low voltage, insofar as the product is used correctly.
The system complies with EN ISO 13849-1:2008, category 2, PLd.
FCC Information
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
IMPORTANT! Any changes or modifications not expressly approved by the part responsible for compliance could void the user’s
authority to operate this equipment.
1248xxx_Rev0.0 RB3 OSE916
Page 4/4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Gemma
Create Date                     : 2015:09:18 09:06:35+02:00
Modify Date                     : 2015:09:18 09:06:38+02:00
Subject                         : 
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2015:09:18 09:06:38+02:00
Creator Tool                    : Acrobat PDFMaker 10.1 para Word
Document ID                     : uuid:61a98575-0b08-4f7d-b7a9-ac1a70767797
Instance ID                     : uuid:87b71cd2-3c01-4890-80fd-ce6a495c6283
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Gemma
Producer                        : Adobe PDF Library 10.0
Keywords                        : 
Source Modified                 : D:20150918070617
Company                         : 
Page Layout                     : OneColumn
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U5Z-RB3OSE916

Navigation menu