Jablotron JA80E Hard wired keypad with RFID card reader User Manual Exhibit 7 Instruction manual JA80E

Jablotron Ltd Hard wired keypad with RFID card reader Exhibit 7 Instruction manual JA80E

Instruction Manual

Download: Jablotron JA80E Hard wired keypad with RFID card reader User Manual Exhibit 7 Instruction manual JA80E
Mirror Download [FCC.gov]Jablotron JA80E Hard wired keypad with RFID card reader User Manual Exhibit 7 Instruction manual JA80E
Document ID891800
Application IDks7Z1MDox0NMn1lVxFgTzQ==
Document DescriptionInstruction Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19.8kB (247549 bits)
Date Submitted2008-01-21 00:00:00
Date Available2008-01-21 00:00:00
Creation Date2008-01-09 15:37:35
Producing SoftwareAFPL Ghostscript 8.53
Document Lastmod2008-01-09 15:37:35
Document TitleExhibit 7 Instruction manual JA80E
Document CreatorFreePDF XP 3.05 - http://shbox.de
Document Author: eschlemmer

The JA-80E hard-wired keypad
however possible to program permanent indication via the control panel, if
considered appropriate.
The JA-80E is a component of Jablotron’s Oasis 80 alarm system and is
designed to control and program the system. It has a built-in proximity
access card reader and allows the wiring up of a separate door detector.
The keypad should be wired to the control panel.
Installing a door detector
It is possible to wire up a detector(s) to the keypad via the IN input. The IN
input terminal is triggered when disconnected from GND. The control panel’s
natural reaction to the IN input being triggered is a delayed intruder alarm
(unchangeable reaction).
Installation
Installation shall only be undertaken by technicians holding a certificate
issued by an authorized distributor. The keypad is for indoor installation
only, typically by a main entrance door.
1. Open the keypad housing (by pressing the tab on the bottom)
and disconnect the inter-housing connection cable inside (by
pulling the connector from the board).
2. Install the rear housing to the desired location.
3. Connect the control panel bus cable. There are two
possibilities:
• Use a flat telephone cable with RJ connectors (max. 10 metres).
There is a digital bus connector in the control panel, and in the
keypad too.
• Use a twisted-pair cable (max. 100m) – the correspondingly marked
terminals in the keypad unit and in the control panel should be
connected together via the cable (GND, A, B, +U)
4. Install the external door detector (if required) and connect its
cable to the IN and GND terminals.
5. Connect the inter-housing cable to the keypad board. Attach
the keypad to the rear housing.
6. Keypad operating instructions are found in the control panel
manual.
digital bus cable
Notes:
• If the IN input is not used, connect it to GND.
• The IN input only reports to the control panel at the moment of being
triggered (a so-called pulse reaction, which means that the keypad cannot
signal permanently open doors).
OASIS 80
ABC
IN
GND
+U
GND
An example of door detector wiring
OASIS 80
Disabling the tamper sensor
To disable the tamper sensor, short out the jumper in the keypad unit close to
the tamper sensor (equipped with a spring). This is useful when carrying the
keypad unit around with a long cable while servicing the system. During
normal system use this jumper must remain open circuited
Keypad text editing
ABC
GND
+U
There are two kinds of text: device and code names (displayed on the
second line after the address number), and other system text.
The names can be edited via the keypad after pressing and holding the
? key in service mode – see the control panel installation manual. The
edited text is only stored in the keypad unit used for editing. If you use a
PC to set the texts, you will set the texts in all keypads.
The most convenient way to edit text is to use a PC running Comlink
software (via the Devices window). To transfer edited text from a PC to
the keypad, the keypad has to be connected to the Oasis system‘s digital
bus as normal (i.e. one cable from the keypad to the control panel, and
another cable from the control panel to the PC). If there are multiple
keypads, they can all be connected together (via the digital bus) while
transferring edited text from the PC, or you can transfer text to each
keypad, one at a time. We recommend using a digital bus splitter (model
BS-84). Comlink software also allows editing of the keypad’s system text
(see the menus: Setting/Keypad Text).
OASIS 80
ABC
IN
GND
+U
GND
Technical specifications
Power
via the control panel bus
Standby consumption
30mA
RFID cards
Jablotron PC-01 or PC-02 (EM UNIQUE 125kHz)
Length of digital bus cable
max. 100m
Door detector input
IN = normally closed loop
Dimensions
113 x 121 x 63 mm
Environment according to EN 50131-1
II. internal
Operating temperature range
-10 to +40 °C
EN 50131-1 and CLC/TS 50131-3 classification
class 2
Keypad menu – language selection and door bell function
If the ∗ key is kept pressed while is being powered-up the internal keypad
menu will be displayed allowing the selection of the desired language. Using
the arrows choose your language and confirm selection by the ∗ key.
In this menu the door bell function can also be enabled or disabled (if
enabled the keypad makes a sound when its IN input is triggered).
To exit the menu, press # (exiting also occurs after 10 seconds’ inactivity).
Notes:
• The keypad power can be switched on by connecting the bus cable or
by switching on the control panel power.
• Each keypad has its own menu, i.e. each keypad in the system can
have its own unique settings.
• The keypad keeps its settings even if its power is disconnected (settings
can only be altered via the keypad menu).
FCC ID: VL6JA80E
Jablotron Ltd. hereby declares that the JA-80E is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC and complies with
part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This
device may not cause harmful interference, and 2. This device must accept any interference
received, including interference that may cause undesired operation.
CAUTION: Changes or modifications no expressly approved by Jablotron could void the
user´s authority to operate the equipment. The original of the conformity assessment can
be found at www.jablotron.com, Technical Support section.
Note: Although this product does not
contain any harmful materials we
suggest you return the product to the
dealer or directly to the producer after
use.
Three minute time-out of displaying the alarm status
To comply with EN standards the keypad does not indicate the status of
the alarm system while the system is set (armed). Indication only returns
when the keypad is operated or an entrance delay is triggered. It is
The JA-80E hard-wired keypad
MHE51201

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 1
Producer                        : AFPL Ghostscript 8.53
Create Date                     : 2008:01:09 15:37:35
Modify Date                     : 2008:01:09 15:37:35
Title                           : Exhibit 7 Instruction manual JA80E
Creator                         : FreePDF XP 3.05 - http://shbox.de
Author                          : eschlemmer
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VL6JA80E

Navigation menu