Jeckson Electric 547-47-1013-T Remote Controller User Manual 47 1013A 090312

Jeckson Electric Co., Ltd Remote Controller 47 1013A 090312

Manual

Download: Jeckson Electric 547-47-1013-T Remote Controller User Manual 47 1013A  090312
Mirror Download [FCC.gov]Jeckson Electric 547-47-1013-T Remote Controller User Manual 47 1013A  090312
Document ID1086761
Application IDSrNLbfnV6kZ+lrsJ4kkXFw==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize4.82kB (60277 bits)
Date Submitted2009-03-27 00:00:00
Date Available2009-03-27 00:00:00
Creation Date2009-03-25 13:57:01
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2009-03-26 09:24:57
Document TitleMicrosoft Word - 47-1013A User Manual 090312.doc
Document CreatorPScript5.dll Version 5.2
Document Author: wongkingmou

Owner's Manual
Wall Switch Style RF Controller, 433MHz
MODEL: 47-1013A-T, 47-1013B-T
FCC ID: ELY547-47-1013-T
IC 1492A-471013T
REMOTE CONTROL
The remote control has a range of approximately 50 ft. (15.25m), it does not have to be
pointed at the fireplace and can pass through most obstacles (including walls).
BATTERY INSTALLATION
1. Depress tab on the battery cover on the side of the remote transmitter and remove
battery cover.
2. Install 2 AAA batteries into the remote control. (included)
3. Replace the battery cover.
AC24V INSTALLATION
1. Depress tab on the cover on the back of the remote transmitter and remove the wire
compartment cover.
2. Remove the 2 lead wires from the wire compartment.
3. Connect the wires to the AC24V hard wires.
4. Replace the cover.
Note: There is an internal electronic switch to disconnect the AAA Battery
power supply when the AC24V~ hard wire hook up is made.
FLAME ON/OFF BUTTON
Press the right
to turn the Flame ON or press the left
PURIFIRE ON/OFF BUTTON
Press the right
to turn the Flame OFF.
(For 47-1013A-T version only)
to turn the Purifire ON or press the left
COUNTDOWN TIMER
to turn the Purifire OFF.
(For 47-1013B-T version only)
To set the Countdown timer, press the left
or right
buttons to decrease or
increase by 30 minute decrements or increments. The countdown timer can be set from 30
minutes to 6 hours. The fireplace will automatically turn OFF when the sleep timer reaches
0 minutes.
SET TEMPERATURE
Press the left
and °C.
or right
direction button together of
to select between °F
Press the left
or right
direction button to decrease or to increase temperature.
Temperature Range 0°C - 37°C (32°F - 99°F).
CAUTION
1. For indoor use in dry areas only.
2. 24 volt AC supply.
WARNING
Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
SPECIFICATIONS
Input Rating…….………………………………………...AC 24V~ or DC3V (Alkaline AA x 2)
Operation Temperature…………………………………….……..……………….... -10 to 70℃
Storage Temperature ………………………………………..….…………………….-25 - 60℃

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2009:03:25 13:57:01Z
Modify Date                     : 2009:03:26 09:24:57-04:00
Page Count                      : 3
Producer                        : GPL Ghostscript 8.15
Creation Date                   : 2009:03:25 13:57:01Z
Mod Date                        : 2009:03:26 09:24:57-04:00
Author                          : wongkingmou
Metadata Date                   : 2009:03:26 09:24:57-04:00
Title                           : Microsoft Word - 47-1013A User Manual 090312.doc
Creator                         : wongkingmou
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ELY547-47-1013-T

Navigation menu