Jiangsu SEUIC Technology AUTOID7 AUTOID7 User Manual

Jiangsu SEUIC Technology Co.,Ltd AUTOID7 Users Manual

Users Manual

Series
Basic function
Data collection
Wireless communication
1D Scanner
2D Scanner
WIFI
IR
Bluetooth
Catalogue
Appearance introduction
Input method
Charging mode
Use of application center
Basic function
Scanner
RS232
USB1.1
Charge
interface
Hand band install
position
Battery
compartment
High-decibel
speaker
Battery cover
lock
Appearance function
Please fasten
the battery cover
when using
Scan key
Blue function key Orange function
key
Enter
Case switch
Delete key
Power key
Backlight
switch
Definition key
Hard keyboard
introduction
Direction keys
With the blue function key to
adjust the volume and screen
brightness
+ +
Any one of the
side keys
Press the three keys together and then
release. You can restart the machine.
1.Restart :data in RAM is lost, but the install won’t be lost
Hard keyboard introduction
2. Recover the device to default setting:all the programs and data will be cleared except
the data on users memory space.
Refer to the guidebook of default setting for details.
The key is an input method switch key, press the orange function key, enter the text input
Before pressing
the orange key
After pressing the
key
After pressing 1
key
After pressing 2
key
3.Use of orange key
Hard keyboard
3Blue function key usage
The key function is Fn, press blue key and then press 1,run F1.
Use the arrow keys with the left and right key to adjust the volume up and
down keys to adjust the screen
Fn setting Click into Set-System, click
Pressing F1 will execute barcode
Scanning can set the hotkey
Blank means no hotkey
Input
1Input
There are three input
methods,such as keyboard\soft
keyboard\hard keyboard
Battery indicator and charging
1Indicator
Not full, double click the icon
to display the power
Low power
Charging
2Charging methods
Full
End plug charging charging time2-3h
Base charging charging time2-3h
Portable charger charging time4-5h
3Cradle introduction
When the PDA is being charged, PDAs red light means
charging, green light means full.
When the battery is being charged in cradle compartment,
the middle light will turn the red to green light.
Attention:
1.The three light-emitting diodes in cradle from left to
right are power entrycharging indicatorUSB data
connection indicator.
2.When the battery will charge fully, the charging LED
will turn out for a short time.
RS232
USB1.1
Both PDA and battery
charging
Optional BT function
AppCenter
You can set the AppCenter. Default password is " seuic "
Open the AppCenter ( path: Start-Programs- AppCenter )
Enter into
management
setting
Display the opened
software
Enter the
password Modify the
password
Software authority
management Set boot from
the start
Data capture
Settings
Hide the 1D
scanner
Click this will
close the 1D scanner
1D Scanner
Setting barcode type
Suggest not modify
1D Scanner
Set remind mode
Set barcode show
mode
Set run program at startup
1D Scanner
1D Scanner(Red light)
Settings
Hide the 1D
scanner
Click this will
close the 1D scanner
1D Scanner(Red light)
Restore scanner
factory Settings
Setting barcode type
Suggest not modify
1D Scanner(Red light)
Set remind mode
Set barcode show
mode
Set run program at startup
1D Scanner(Red light)
2D Scanner
Enter intoAppCenter”,click
Start the 2D scanner
2D Scanner
Clean the barcode information in
the screen
Image capture function can
capture black and white pictures
Recover to default settings
Save the modified settings
Attention: each time modify
Parameters, click saving
Hide the 2D software
Exit
2D Scanner
If you want to output the code to txt or
excel, you need to choose Clipboard or
Simulate Key
Set the time interval
Set automatic and auto scan delay
2D Scanner
1Set scaner light
general select Both
aimer And LED
2If code is white, background is
black. Please select Enable
Colour Reverse
3Scan mode general
" standard ".
4Set the scan prompt
5Display code
information
Cancel all display
information
Select all display
information
Reset Statisitcs can
clear it
6Barcode
type open or
close
7
Barcode
configuration
recovery
8Hide the 2D
software
2D Scanner
Wireless communication
Wireless technical parameters
WLAN--------WiFi
standardIEEE802.11b/g
Frequency range: 2.4/2.5GHz
safetyWEPTKIPLEAPPEAPEAP-TLS
WPAWPA2AES
WPAN--------Bluetooth V2.0+EDR
Data rate3Mbps
frequency2.4GHz
standardIEEE802.15.1
/n
WLAN ---- WIFI
WiFi
1Open hardwareEnter into “wireless manager”
if display “Disable”, means hardware is
open.If display “Enable”, click it to open
the hardware.
AttentionYou dont need to do the operation
next time you start the PDA.
WiFi
2Set IP addressIf you need to set
fixed IP,enter into “Control Panel”
click “Network and Dial-up connections”,
click “WIFI”.
AttentionYou dont need to do the
operation next time you start the PDA.
3Connect a networkDouble click the
red circle, click “Wireless information” .
Double click the network you want to
Connect, and set the net parameters
WiFi
Connect a network ok
4Wi-Fi Manager click red circle icon
,start the Wifi manager
WIFI icon means
No WiFi module
WIFI module disable
No AP single around
There is single around,but not connection
PDA has connected with AP
Display the
current state and
parameters
WiFi
5Ping testclick“ping” click “Start”
will do the Ping operation.
The more data lost,the worse performance
Attention: Some gateway and AP can’t allow
to ping operation.
WiFi
single strength
6WIFI Config Set Power Save/Roam
Trigger/Roam Delta/Roam Period
Power Save:Set power save mode,the more power
saving,the worse performance
Roam Trigger:Setting roaming switching values
WiFi
Infrared(power not control in
old version)
2Serial Port select COM1,click “file” -“settings”
set the communication protocol. The Baud Rate:1200
or2400.The port communication protocolmust the same
as the IR device settings.As the below figure
1Click“ ”-“Run”input “ cechat”click OK
Set parameters as you need
Infrared(power control in new
version)
The latest infrared machine is controlled by power in receiving data.
So we need two infrared machines to test infrared
communication ,which need users to write a demo programe.
The development method of infrared is as follows
on():open the power control
off():close the power control
SetRecvState():set infrared to receive
SetSendState():set infrared to send
1Open hardwareEnter into “Wireless Manager”if display Disable”, means
hardware is open.If display “Enable”, click it to open the hardware.
Bluetooth function
AttentionYou dont need to do the operation next time you start the PDA.
2Enter into Windows file, start the
PrintUI software, just as the right
Figure. Attention: just start one PrintUI
Bluetooth function
3Connect other bluetooth device
Click “Inquiry”, other bluetooth devices
around will display in the text box.Select
one bluetooth device,click OK
Bluetooth function
Bluetooth function
4Connect bluetooth device
You need to input the Select
Channel number, as the right figure
Connect successful
Bluetooth function
5send and receive data
You can send and receive data by using
cechat.
You should copy the cechat software into
PDA,then start cechat.Serial Port select
COM3.Then you can send and receive data.
Or:by below pathway:
Start-run input”cechat”,then
enter.
Start Bluetooth in AppCenter
1.Enter into application management, choose the third party
program management.
2.Click “add” button.
3.Look for “printui”in windows files, click ok.
4.Choose “show on the desk”, click ok.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference
by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Technical support mailzoujianjun@seuic.com
Tel86-25-52261298
Fax86-25-52261298-8858
URLwww.seuic.com
Hotline400-777-0876
Service mailboxAUTOID6@seuic.com
Postal210006
AddressNo 23. Wenzhu Road. Yuhuatai
District. Nanjing. China(210012)
Thank you!