Jiangsu SEUIC Technology AUTOID7 AUTOID7 User Manual
Jiangsu SEUIC Technology Co.,Ltd AUTOID7 Users Manual
Users Manual
Series Catalogue Basic function Appearance introduction Input method Charging mode Use of application center Data collection 1D Scanner 2D Scanner Wireless communication WIFI IR Bluetooth Basic function Appearance function Scanner Hand band install position RS232 High-decibel speaker Battery compartment Battery cover lock Please fasten the battery cover when using USB1.1 Charge interface Hard keyboard introduction Scan key Definition key Direction keys With the blue function key to adjust the volume and screen Enter brightness Case switch Delete key Power key Backlight switch Blue function key Orange function key Hard keyboard introduction 1.Restart :data in RAM is lost, but the install won’t be lost Press the three keys together and then release. You can restart the machine. Any one of the side keys 2. Recover the device to default setting:all the programs and data will be cleared except the data on user’s memory space. Refer to the guidebook of default setting for details. 3.Use of orange key The key is an input method switch key, press the orange function key, enter the text input Before pressing the orange key After pressing the key After pressing 1 key After pressing 2 key Hard keyboard 3、Blue function key usage The key function is Fn, press blue key and then press 1,run F1. Use the arrow keys with the left and right key to adjust the volume up and down keys to adjust the screen Fn setting :Click into Set-System, click Pressing F1 will execute barcode Blank means no hotkey Scanning can set the hotkey Input 1、Input There are three input methods,such as keyboard\soft keyboard\hard keyboard Battery indicator and charging 1、Indicator Full Not full, double click the icon to display the power Low power Charging 2、Charging methods End plug charging charging time:2-3h Base charging charging time:2-3h Portable charger charging time:4-5h 3、Cradle introduction When the PDA is being charged, PDA’s red light means charging, green light means full. When the battery is being charged in cradle compartment, the middle light will turn the red to green light. Attention: 1.The three light-emitting diodes in cradle from left to right are power entry、 charging indicator、 USB data connection indicator. 2.When the battery will charge fully, the charging LED will turn out for a short time. RS232 USB1.1 Both PDA and battery charging Optional BT function AppCenter Open the AppCenter ( path: Start-Programs- AppCenter ) You can set the AppCenter. Default password is " seuic " Enter into management setting Enter the password Display the opened software Software authority management Modify the password Set boot from the start Data capture 1D Scanner Settings Click this will close the 1D scanner Hide the 1D scanner 1D Scanner Setting barcode type Suggest not modify 1D Scanner Set remind mode Set barcode show mode Set run program at startup 1D Scanner(Red light) 1D Scanner(Red light) Settings Click this will close the 1D scanner Hide the 1D scanner 1D Scanner(Red light) Setting barcode type Suggest not modify Restore scanner factory Settings 1D Scanner(Red light) Set remind mode Set barcode show mode Set run program at startup 2D Scanner 2D Scanner Enter into “AppCenter”,click Start the 2D scanner 2D Scanner Clean the barcode information in the screen Image capture function can capture black and white pictures Recover to default settings Save the modified settings Attention: each time modify Parameters, click saving Hide the 2D software Exit 2D Scanner Set automatic and auto scan delay Set the time interval If you want to output the code to txt or excel, you need to choose Clipboard or Simulate Key 2D Scanner 1、Set scaner light general select Both aimer And LED 2、If code is white, background is black. Please select Enable Colour Reverse 3、Scan mode :general " standard ". 4、Set the scan prompt 5、Display code information Cancel all display information Select all display information Reset Statisitcs can clear it 6、Barcode type open or close 7、Barcode configuration recovery 8、Hide the 2D software Wireless communication Wireless technical parameters WLAN--------WiFi standard:IEEE802.11b/g/n Frequency range: 2.4/2.5GHz safety: WEP、TKIP、LEAP、PEAP、EAP-TLS 、WPA、WPA2、AES WPAN--------Bluetooth V2.0+EDR Data rate:3Mbps frequency:2.4GHz standard:IEEE802.15.1 WLAN ---- WIFI WiFi 1、Open hardware:Enter into “wireless manager”, if display “Disable”, means hardware is open.If display “Enable”, click it to open the hardware. Attention:You don’t need to do the operation next time you start the PDA. WiFi 2、Set IP address:If you need to set fixed IP,enter into “Control Panel” , click “Network and Dial-up connections”, click “WIFI”. Attention:You don’t need to do the operation next time you start the PDA. WiFi 3、Connect a network:Double click the red circle, click “Wireless information” . Double click the network you want to Connect, and set the net parameters Connect a network ok WiFi 4、Wi-Fi Manager :click red circle icon ,start the Wifi manager WIFI icon means: No WiFi module。 WIFI module disable No AP single around There is single around,but not connection PDA has connected with AP Display the current state and parameters WiFi 5、Ping test:click“ping” ,click “Start” will do the Ping operation. The more data lost,the worse performance single strength Attention: Some gateway and AP can’t allow to ping operation. WiFi 6、WIFI Config :Set Power Save/Roam Trigger/Roam Delta/Roam Period Power Save:Set power save mode,the more power saving,the worse performance Roam Trigger:Setting roaming switching values Infrared(power not control in old version) 1、Click“ ”-“Run”,input “ cechat”,click OK 2、Serial Port select COM1,click “file” -“settings”, set the communication protocol. The Baud Rate:1200 or2400.The port communication protocolmust the same as the IR device settings.As the below figure Set parameters as you need Infrared(power control in new version) The latest infrared machine is controlled by power in receiving data. So we need two infrared machines to test infrared communication ,which need users to write a demo programe. The development method of infrared is as follows on():open the power control off():close the power control SetRecvState():set infrared to receive SetSendState():set infrared to send Bluetooth function 1、Open hardware:Enter into “Wireless Manager”, if display Disable”, means hardware is open.If display “Enable”, click it to open the hardware. Attention:You don’t need to do the operation next time you start the PDA. Bluetooth function 2、Enter into Windows file, start the PrintUI software, just as the right Figure. Attention: just start one PrintUI Bluetooth function 3、Connect other bluetooth device Click “Inquiry”, other bluetooth devices around will display in the text box.Select one bluetooth device,click OK Bluetooth function 4、Connect bluetooth device You need to input the Select Channel number, as the right figure Connect successful Bluetooth function 5、send and receive data: You can send and receive data by using cechat. You should copy the cechat software into PDA,then start cechat.Serial Port select COM3.Then you can send and receive data. Or:by below pathway: Start-run input”cechat”,then enter. Start Bluetooth in AppCenter 1.Enter into application management, choose the third party program management. 2.Click “add” button. 3.Look for “printui”in windows files, click ok. 4.Choose “show on the desk”, click ok. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Thank you! Tel:86-25-52261298 Fax:86-25-52261298-8858 URL:www.seuic.com Hotline:400-777-0876 Service mailbox:AUTOID6@seuic.com Postal:210006 Address: No 23. Wenzhu Road. Yuhuatai District. Nanjing. China(210012) Technical support mail:zoujianjun@seuic.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseNone XMP Toolkit : 3.1-701 Create Date : 2014:12:16 18:38:29+08:00 Modify Date : 2014:12:30 18:12:59+08:00 Metadata Date : 2014:12:30 18:12:59+08:00 Producer : doPDF Ver 7.3 Build 391 (Windows XP Professional Edition (SP 3) - Version: 5.1.2600 (x86)) Format : application/pdf Document ID : uuid:981bddd8-c4d5-44ad-a031-5c2dc5c1fda3 Instance ID : uuid:291d0757-dce0-414f-b8e1-d0fc01df736c Page Count : 44 Page Layout : OneColumnEXIF Metadata provided by EXIF.tools