Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 1/42 tec@usr.cnRS232RS232RS232RS232 /RS485/RS485/RS485/RS485 TOTOTOTO RJ45&WIFIRJ45&WIFIRJ45&WIFIRJ45&WIFI CONVERTCONVERTCONVERTCONVERTSERVERSERVERSERVERSERVER( USR-WIFI232-610/604/602/2 )File version: Ver 2.0.0
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 2/42 tec@usr.cnContentRS232/RS485 TO RJ45&WIFI CONVERT SERVER ............................................................................................ 11. Quick Start ........................................................................................................................................................... 41.1. Hardware connect .................................................................................................................................... 41.2. Network connection ................................................................................................................................. 41.3. Communication test ................................................................................................................................. 52. Introduction .......................................................................................................................................................... 62.1. Short Description ...................................................................................................................................... 62.2. Device Features ....................................................................................................................................... 72.3. Electronic Parameters .............................................................................................................................. 72.4. Packing Information ................................................................................................................................. 83. Hardware ............................................................................................................................................................. 93.1. Appearance size chart ............................................................................................................................. 93.2. Indicator Light ........................................................................................................................................... 93.3. Interface Instructions .............................................................................................................................. 104. Application .........................................................................................................................................................114.1. Application of AP ....................................................................................................................................114.2. Application of STA ..................................................................................................................................114.3. Application of AP+STA ........................................................................................................................... 124.4. Wired and wireless Application drawing (Only 610 apply )............................................................... 134.5. Application of wireless serial port(oneAP,one STA) ........................................................................... 145. Function Description ......................................................................................................................................... 155.1. User configuration process .................................................................................................................... 155.2. Working mode ........................................................................................................................................ 165.2.1. Transparent Transmission Mode ................................................................................................ 165.2.2. Serial command mode ................................................................................................................ 175.2.3. HTTPD Client mode .................................................................................................................... 185.3. WI-FI parameter setting ......................................................................................................................... 195.3.1. Auto- Frequency Function .......................................................................................................... 195.3.2. Security ........................................................................................................................................ 195.3.3. Search Function for STA ............................................................................................................. 195.3.4. Address Binding .......................................................................................................................... 205.4. UART Frame Scheme ............................................................................................................................ 205.4.1. UART Free-Frame ....................................................................................................................... 205.4.2. UART Auto-Frame ....................................................................................................................... 205.5. Network Setting ...................................................................................................................................... 215.5.1. Socket A ....................................................................................................................................... 215.5.2. Socket B ....................................................................................................................................... 215.6. New function ........................................................................................................................................... 225.6.1. TCP password authentication ..................................................................................................... 225.6.2. Upload ID ..................................................................................................................................... 22
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 3/42 tec@usr.cn5.6.3. Self-adaption Baudrate ............................................................................................................... 225.6.4. Keepalive ..................................................................................................................................... 235.6.5. MultipleSTAparameters ............................................................................................................. 235.6.6. Websocket ................................................................................................................................... 235.7. Palmodic Signal ...................................................................................................................................... 245.8. Parameters Configuration ...................................................................................................................... 245.9. Firmware Upgrade ................................................................................................................................. 256. setup process .................................................................................................................................................... 256.1. Configuration via Web Accessing .......................................................................................................... 256.1.1. Open Web Management Interface ............................................................................................. 256.1.2. Quick Configure ........................................................................................................................... 266.1.3. Mode Selection Page .................................................................................................................. 276.1.4. AP Interface Setting Page ........................................................................................................... 286.1.5.STAInterface Setting Page ......................................................................................................... 286.1.6. Application Setting Page ............................................................................................................. 296.1.7. Ethernet Setting ........................................................................................................................... 316.1.8. HTTPD Client Mode .................................................................................................................... 316.1.9. Device Management Page ......................................................................................................... 32Appendix A: Questions and Answers ................................................................................................................... 34Q1: How to configure transparent serial port application (TCP protocol) with two Convert Servers? ...... 34Q2: Where to Set WIFI Convert Server LAN IP and WAN IP through Web Page ?................................. 35Q3: How to configure transparent serial port application (UDP protocol) with two Convert Servers? ...... 35Q4: Where to set Convert Server network protocol (TCP/UDP)? ............................................................... 36Q5: How to configure transparent serial port application: Two Convert Servers all configured asSTAandconnection through AP? ................................................................................................................................ 37Q6: How to avoid IP address confliction when apply Convert Server? ...................................................... 38Q7: PC works as server, all Convert Servers works as data acquisition card and connect with PC, how toconfigure this application? ............................................................................................................................. 38Q8: Convert Server support UDP multicast? ............................................................................................... 40Q9:Convert Server operates inSTAmode, the PC how to get the IP Convert Server? ............................ 40Appendix b: The FCC statement .......................................................................................................................... 41Appendix c: Contact .............................................................................................................................................. 42Appendix d: Disclaimer ......................................................................................................................................... 42Appendix e: Update History .................................................................................................................................. 42
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 4/42 tec@usr.cn1.1.1.1. QuickQuickQuickQuick StartStartStartStartThis chapter is the quick start for Convert Server . proposal user read this chapter and follow the instructions.This will help your understanding of the product. Of course, the user can choose read chapters according toneed . For specific details and instructions, please refer to the following.1.1.1.1.1.1.1.1. HardwareHardwareHardwareHardware connectconnectconnectconnectIn order to test the serial port to the WIFI/ Ethernet communication transformation,connect the the deviceserial port to PC serial port, connect the device WIFI/Ethernet to PC WIFI/Ethernet .If the desktop does notown the serial port, also can use USB 232 to replace. The hardware environment.EthernetDC5 -18V232485Select EthernetorWIFISelect 232 or 485FigureFigureFigureFigure 1111 HardwareHardwareHardwareHardware Connect(610)Connect(610)Connect(610)Connect(610)According to the above connect Convert Server.1.2.1.2.1.2.1.2. NetworkNetworkNetworkNetwork connectionconnectionconnectionconnectionOpen Wi-Fi, search network on the PC , as shown in below, USR-WIFI232- AP_3378 is the default networkname (SSID) of the Convert Server .Note: if the firmware version is V4, the SSID is "HF - A11x_AP".After the SSID is also like this.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 5/42 tec@usr.cnFigureFigureFigureFigure 2222 WIFIWIFIWIFIWIFI SearchSearchSearchSearchJoin the network, choose to automatically obtainIP,Convert Server supports DHCP Server feature and isenabled by default.FigureFigureFigureFigure 3333 WIFIWIFIWIFIWIFI connectionconnectionconnectionconnectionNow, link led of Convert Server is lighting.1.3.1.3.1.3.1.3. CCCC ommunicationommunicationommunicationommunication testtesttesttestConvert Server ’s default setting:SSID:SSID:SSID:SSID: USR-WIFI232-D2_xxxx(xxxx is the last of mac address);EncryptionEncryptionEncryptionEncryption modemodemodemode ::::open ,none ;UART:UART:UART:UART: 57600 ,8,1,None ;
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 6/42 tec@usr.cnNetworkNetworkNetworkNetwork parametersparametersparametersparameters :TCP,Server,8899,10.10.100.254 ;IP:IP:IP:IP: 10.10.100.254;We just need to follow the parameters of the corresponding set of network communication parameters, youcan make serial < -- > WIFI or Ethernet communication, the steps are as follows:1. Open test software USR-TCP232-Test ;2. COM Settings area (left):C hoose COM port witch has connect the Convert Server , there is COM3, choose band rate to 57600 , this isthe default band rate of Convert Server , Click Open COM port.3. Net Settings area (right):C hoose TCP client mode, Server IP write 10.10.100.254, it is the WIFI default IP address, Server port to 8899,It is the default Port the Convert Server listen, Click Connect to link to the Convert Server .Now, you can test send data between RS232 and WIFI.COM port to WIFI: PC RS232 -> Convert Server RS232 -> Convert Server WIFI -> PC WIFI .WIFI to COM port: PC WIFI or Ethernet -> Convert Server WIFI or Ethernet -> Convert Server RS232 -> PCRS232.FigureFigureFigureFigure 4444 serialserialserialserial //// networknetworknetworknetwork transmissiontransmissiontransmissiontransmission testtesttesttest2.2.2.2. IntroductionIntroductionIntroductionIntroduction2.1.2.1.2.1.2.1. ShortShortShortShort DescriptionDescriptionDescriptionDescriptionConvert Server provides a serial port to WIFI function, can be RS-232/485 converted into a TCP/IP serialnetwork interface, RS-232/485 serial port and WIFI/ Ethernet bidirectional data transparent transmission. Theserial device can immediately with the TCP/IP network interface functions, connect to the network for data
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 7/42 tec@usr.cncommunication, communication range extended serial device greatly.Convert Server series currently has USR-WIFI232-610, USR-WIFI232-604,USR-WIFI232-602,USR-WIFI232-2 lighting products. Specific parameters of each product please refer to below:TableTableTableTable 1111 ProductProductProductProduct modelmodelmodelmodelType RS232 RS485 Ethernet I nputVoltage Size(mm)USR-WIFI232-610 YES YES YES 5-18V 84*84*25USR-WIFI232-604 NO YES NO 5-9V 84*84*25USR-WIFI232-602 YES NO NO 5-9V 84*84*25USR-WIFI232-2 YES NO NO 5-9V 80*50*14 (No Shell )2.2.2.2.2.2.2.2. DeviceDeviceDeviceDevice FeaturesFeaturesFeaturesFeaturesInner b oard core module specifications , please reference to USR-WIFI232-CSupport hardware flow control (RTS/CTS) RS232 interface, male mouth(needle) consistent withcomputer pin definitionRS232 RS485 automatic switching (USR-WIFI232-610)RJ45 network connection, support wired Ethernet transmission (USR-WIFI232-610)Reload button, do not worry incorrect settings ( in working status, press the button 3 s then it load todefault s ettings and automatic restart)Rich status indicator light : Power / Ready / Link / RXD / TXDPin 9 of the DB9 can be connected to p ower input (solder jumper on the back of PCB ), used for powerthe sensor or the serial port cable power Convert Server .D esign with positioning hole, convenient installationH ighest support baud rate 460800 bpsoptional TCP Server/TCP Client/UDP Client/ UDP Server mode, the TCP Server mode can support up to32 Client connection2.3.2.3.2.3.2.3. EEEE lectroniclectroniclectroniclectronic PPPP arametersarametersarametersarametersTableTableTableTable 2222 ElectricalElectricalElectricalElectrical parameterparameterparameterparameterItem ParameterWirelessparameterCertification FCC/CEWirelessstandard802.11 b/g/nFrequency range 2.412GHz-2.484GHzTransmit power802.11b: +20dBm(Max.)802.11g: +18dBm(Max.)802.11n: +15dBm(Max.)
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 8/42 tec@usr.cnconfigurableReceiverSensitivity802.11b: -89dBm802.11g: -81dBm802.11n: -71dBmAntenna Option Externa l 3Dbi antennaHardwareParametersData InterfaceUART : 1200bps - 230400bpsEthernet : 100MpbsGPIOsOperatingvoltage5-18V (+/-5%)Operatingcurrent170mA~300mAOperatingtemperature-25 ℃- 85 ℃Storagetemperature-40 ℃- 125 ℃Dimensions 83 × 80 × 25mmSoftwareparametersNetwork type Station/AP mode , STA+APSecuritymechanismsWEP/WPA-PSK/WPA2-PSK/WAPIEncryption WEP64/WEP128/TKIP/AESWork mode Transparent TransmissionSerial command AT+instruction setNetworkProtocolTCP/UDP/ARP/ICMP/DHCP/DNS/HTTPMax. TCPConnection32UserConfigurationWeb Server +ATcommand configUser ApplicationSWSupport customized application software2.4.2.4.2.4.2.4. PackingPackingPackingPacking InformationInformationInformationInformationConvert Server *15V1A power adapt e r *1Serial cable *1 (only USR-WIFI232-610)Network cable *1 (only USR-WIFI232-610)User guide CD *1 (only USR-WIFI232-610)
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 9/42 tec@usr.cn3.3.3.3. HardwareHardwareHardwareHardware3.1.3.1.3.1.3.1. AppearanceAppearanceAppearanceAppearance sizesizesizesize chartchartchartchartFigureFigureFigureFigure 5555 AppearanceAppearanceAppearanceAppearance sizesizesizesize chartchartchartchart (602/604/610)(602/604/610)(602/604/610)(602/604/610)3.2.3.2.3.2.3.2. IndicatorIndicatorIndicatorIndicator LLLL ightightightightThere are 5 lights in total, from left to rightTableTableTableTable 3333 IndicatorIndicatorIndicatorIndicator lightlightlightlightIndicator Function DescriptionPower power Keep light when power onReady Inner LINUX start Keep green light when connected to networkcorrectlyLink Network link Light when establish network linkTXD Transmit data Flash when send dataRXD Receive data Flash when receive data
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 10/42 tec@usr.cn3.3.3.3.3.3.3.3. IIII nterfacenterfacenterfacenterface IIII nstructionsnstructionsnstructionsnstructionsPowerPowerPowerPower interface:interface:interface:interface:5.5*2.1 standard 5-18v power interface, with TVS protectionRS232RS232RS232RS232 interface:interface:interface:interface: (USR-WIFI232-610/(USR-WIFI232-610/(USR-WIFI232-610/(USR-WIFI232-610/ 60606060 2/2/2/2/ 2222 ))))Device serial port is male(needle), RS232 level (can connect to PC directly), pin order is consistent with PCCOM port. Use cross cable connected with PC(2-3cross,7-8cross, 5-5 direct, 7-8 can disconnect, but MUSTNOT connect with PC directly), There are 6 pins in work, others is NC.TableTableTableTable 4444 RS232RS232RS232RS232 PPPP inininin ssssID NAME DESCRIPTION2 RXD Receive data pin3 TXD Send data pin5 GND Data Ground7 RTS Request to send8 CTS Clear to send9 VCC Can connect to Convert Server power input by join the PCBjumper, default not connect.RS485RS485RS485RS485 interface:interface:interface:interface: (USR-WIFI232-610/(USR-WIFI232-610/(USR-WIFI232-610/(USR-WIFI232-610/ 60606060 4)4)4)4)R S 485 two wire links, A(DATA+), B(DATA-), when link to other RS485 device, A(+) to A(+), B(-) to B(-).RJ45RJ45RJ45RJ45 interface:interface:interface:interface: (USR-WIFI232-610)(USR-WIFI232-610)(USR-WIFI232-610)(USR-WIFI232-610)Network port connection, Convert Server is 10M/100M adaptive, support AUTO MDI/MDIX, which means youcan use direct network cable to connect with PC also can be tested. Convert Server by default open , asshown in the Convert Server specificatio n s.TableTableTableTable 5555 RJ45RJ45RJ45RJ45 PinsPinsPinsPinsID TAB FUNCTION1 TX+ Transceiver Data+2 TX- Transceiver Data-3 RX+ Receive Data+4 PHY-VCC Transformer tap voltage5 PHY-VCC Transformer tap voltage6 RX- Receive Data-7 n/c Not connected8 n/c Not connected
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited11 /42 tec@usr.cnReloadReloadReloadReload key:key:key:key:This key used for set up the Convert Server to factory setting, when Convert Server is working (Ready LEDon), press this key more than 1 seconds and free it, wait about 10 seconds until the Convert Server restart,the green LEDs all off and then Ready LED on. Then the Convert Server goes to factory default settings.4.4.4.4. ApplicationApplicationApplicationApplication4.1.4.1.4.1.4.1. ApplicationApplicationApplicationApplication ofofofof APAPAPAPAs shown in figure in, Convert Server used as anAP,all the other Convert Servers and computer can be usedas theSTAto connect this Convert Server , at the same time it also can through the UART or GPIO interfaceto the user equipment.4.2.4.2.4.2.4.2. ApplicationApplicationApplicationApplication ofofofof STASTASTASTA
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 12/42 tec@usr.cnConvert Server as STA(use the AP CLI interface), connect to otherAP,to compose a wireless network. All oftheSTAtake AP as the wireless network center, and the mutual communication betweenSTAis through APforwarding.4.3.4.3.4.3.4.3. ApplicationApplicationApplicationApplication ofofofof AP+STAAP+STAAP+STAAP+STA
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 13/42 tec@usr.cnConvert Server can support AP+STA mode. That is the Convert Server support a AP interface and aSTAinterface at the same time.AP+STA function settings:AP+STA function need to set through serial command.AT+FAPSTA=on set AP+STA functionThen set Convert Server toSTAmode, the AP interface still valid .Note: the AT command part of this article is no longer in detail, please click the high-performance seriesConvert Server specification.4.4.4.4.4.4.4.4. WiredWiredWiredWired andandandand wirelesswirelesswirelesswireless ApplicationApplicationApplicationApplication drawingdrawingdrawingdrawing ((((OnlyOnlyOnlyOnly 610610610610 applyapplyapplyapply ))))
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 14/42 tec@usr.cnWhen USR-WIFI232- 610 used asAP,other computers and equipments can be used asSTAconnected tothis device through RJ45(network cable).When USR-WIFI232- 610 used as STA, network port connected to computer via RJ45, wireless added towireless router to networking.4.5.4.5.4.5.4.5. ApplicationApplicationApplicationApplication ofofofof wirelesswirelesswirelesswireless serialserialserialserial port(oneport(oneport(oneport(one AP,AP,AP,AP, oneoneoneone STA)STA)STA)STA)
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 15/42 tec@usr.cnConvert Server can be set asSTAorAP.So the device logically supports two wireless interfaces, one as STA,another interface is equivalent to aAP,other STAs can connect to wireless network via the Convert Server APinterface.5.5.5.5. FFFF unctionunctionunctionunction DDDD escriptionescriptionescriptionescription5.1.5.1.5.1.5.1. UserUserUserUser configurationconfigurationconfigurationconfiguration processprocessprocessprocessAfter Convert Server electric starter, based on user pre-set parameters, automatically connect to wirelessnetworks and servers, and enter the working mode is set to open in accordance with the default serial portparameters.The parameters which need to configure include:Wireless Network ParametersWireless Network Name (SSID )Security ModeEncryption Key
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 16/42 tec@usr.cnTCP/UDP Linking ParametersProtocol TypeLink Type (Server or Client )Target Port ID NumberTarget Port IP AddressSerial Port ParametersBaud RateData BitParity (Check) BitStop BitHardware Flow ControlWork Mode SelectionTransparent transmission /Serial command mode/GPIO mode/HTTPD Client modeThe following sections will introduce specific to each part in detail.5.2.5.2.5.2.5.2. WorkingWorkingWorkingWorking modemodemodemode5.2.1.5.2.1.5.2.1.5.2.1. TransparentTransparentTransparentTransparent TransmissionTransmissionTransmissionTransmission ModeModeModeModeConvert Server support serial interface transparent transmission mode. The benefit of this mode is achievesa plug and play serial data port, and reduces user complexity furthest. In this mode, user should onlyconfigure the necessary parameters. After power on, Convert Server can automatically connect to the defaultwireless network and server.As in this mode, the Convert Server 's serial port always work in the transparent transmission mode, so usersonly need to think of it as a virtual serial cable, and send and receive data as using a simple serial. In otherwords, the serial cable of users’original serial devices is directly replaced with the Convert Server ; userdevices can be easy for wireless data transmission without any changes.The transparent transmission mode can fully compatible with user ’ s original software platform and reduce thesoftware development effort for integrate wireless data transmission.Notes:Notes:Notes:Notes: Users also open the serial port hardware flow control (CTS/RTS) function, so that we can make the biterror rate to a minimum.If the user doesn't need hardware flow control function of the serial port, only need tothe corresponding pin foot (CTS/RTS) hung up.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 17/42 tec@usr.cn5.2.2.5.2.2.5.2.2.5.2.2. SerialSerialSerialSerial commandcommandcommandcommand modemodemodemodeIn this mode, the user can send the serial data to a different server address, this pattern can be use UDP orTCP client sends data to the server.Customer MCU send packets according to the following format, parsing Convert Server is finished, only the nbytes of data sent to the destination address.When data is returned, not analytical data from serial port outputdirectly.TableTableTableTable 6666 ProtocolProtocolProtocolProtocol tabletabletabletable ofofofof SerialSerialSerialSerial commandcommandcommandcommand modemodemodemodeframeheaderlength functionbyteBackupdata areaDestination portTargetaddressData Sumcheck2 2(n+m+5)1 2 2 m n 1frameframeframeframe headerheaderheaderheader :0x55 0xAA (Constant )LengthLengthLengthLength :Starting from the function byte, to Sum check (does not contain the sum check) all bytes. High byte atthe frontFunctionFunctionFunctionFunction bytebytebytebyte :Bit0: (UDP:0 ;TCP:1 )Bit1: (Short connection:0;Long connection:1 )Bit2: (IP:0;Domain name:1 )Bit7: (cut protocol:0;full protocol:1 )Note: currently only supports cut protocolNotes:Bit1:If it is a short connection, it sends data, and then will be disconnected; if it is long connection, itsends data, connection will remain, until the re changing the target address.Bit2:Indicates that the target address isIPor domain name. If it isIP,the target address is 4 bytes; if thedomain name, the target address length for the entire domain name string length (the last byte address is‘ \0 ’ , that is the end of the string).Bit7:Under the cut protocol, reply frame contains only data; Under the full protocol, reply frame has"failed to send", "waiting for", "UDP radio response equipment IP" frame data.BackupBackupBackupBackup datadatadatadata areaareaareaarea ::::First byte:If it is a short connection, this position is TCP waits for the timeout time (1-255), if the sendcommand is completed, did not receive a response, then wait a few seconds and the corresponding, if 5,said to wait for the 5S to disconnect; if the sending command, immediately receive the returned data,then immediately disconnected; if it is long connection, this position is 0x00.Second byte:ReserveDestinationDestinationDestinationDestination portportportport ::::Little endian, low byte in the former,such as port 23, here are 0x17 0x00TargetTargetTargetTarget address:address:address:address:If it isIP,is 4 bytes, for example, 192.168.0.7 said 0x07 0x00 0xA8 0xC0; if it is a domain name, then theaddress of indefinite length,ending with the ’ \0'.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 18/42 tec@usr.cnData:Data:Data:Data:Variable length,the maximum not exceeding 1000bytes.SumSumSumSum check:check:check:check:From the function word to check byte (does not contain a check byte), add Sum check.The following is an example of a specific application:send data:0x55 0xaa 0x00 0x0a 0x00 0x00 0x00 0x21 0x00 0x85 0x00 0xA8 0xC0 0x01 0x0fLength:0x00 0x0aFunction byte:0x00 (UDP;Short connection;IP;cut protocol)Destination port :0x21 0x00(33)Target address: 0x85 0x00 0xA8 0xC0 (192.168.0.133)Data:0x01(data length :1)Sum check:0x0f ( 0x00+0x00+0x00+0x21+0x00+0x85+0x00+0xA8+0xC0+0x01=0x0f )5.2.3.5.2.3.5.2.3.5.2.3. HTTPDHTTPDHTTPDHTTPD ClientClientClientClient modemodemodemodeThis mode is used to send data to the HTTP server.After setting the HTTP header format by webpage orATcommand, the data sent each time by UART will addthe HTTP header automatically.Convenient for the user directly submit data or read data from the HTTPserver.Below is the specific application, for example:The first set HTTP parameters using AT instructions.AT+HTTPURL=192.168.1.1,80 The serveraddress and portsettingsAT+HTTPTP=POST Set the HTTP type, GET, PUT orPOSTAT+HTTPPH=/set Set the path,the mostis50 bytesAT+HTTPCN=keep-alive Set the Connection,maximum lengthof 20bytesAT+HTTPUA=lwip13.2 Set the User-Agent,maximum lengthof 20bytesIf the sending data is 1234.In the 80 port of 192.168.1.1 will receive the following dataPOST /set HTTP /1.1Connection:keep-aliveUser-Agent:lwip1.3.2Content-Length:4Host:192.168.1.1:801234If the HTTP type is GET, the 80 port 192.168.1.1 receive dataPOST /set 1234 HTTP /1.1Connection:keep-aliveUser-Agent:lwip1.3.2Content-Length:0
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 19/42 tec@usr.cnHost:192.168.1.1:80Data received from server will be directly sent to the serial port,without any treatment.5.3.5.3.5.3.5.3. WI-FIWI-FIWI-FIWI-FI parameterparameterparameterparameter settingsettingsettingsetting5.3.1.5.3.1.5.3.1.5.3.1. Auto-Auto-Auto-Auto- FrequencyFrequencyFrequencyFrequency FunctionFunctionFunctionFunctionWhen Convert Server works as STA, Convert Server will adjust its wireless channel to keep the samechannel with associated AP and connect in.When Convert Server works as AP and Convert Server enable Auto-frequency function, then when ConvertServer boot up, it will select the best wireless channel based on surrounding environment.5.3.2.5.3.2.5.3.2.5.3.2. SecuritySecuritySecuritySecurityConvert Server supports multiple wireless encryption mechanisms, and enables to protect the security ofuser’s data transmission, the mechanisms include:WEPWPA-PSK/TKIPWPA-PSK/AESWPA2-PSK/TKIPWPA2-PSK/AES5.3.3.5.3.3.5.3.3.5.3.3. SearchSearchSearchSearch FunctionFunctionFunctionFunction forforforfor STASTASTASTAWhen using web configurationSTAInterface Setting Page, user can push “ Search ” button to find surroundingAP,and find a AP to associated.FigureFigureFigureFigure 6666 SearchSearchSearchSearch pagepagepagepage
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 20/42 tec@usr.cn5.3.4.5.3.4.5.3.4.5.3.4. AddressAddressAddressAddress BindingBindingBindingBindingConvert Server supports the feature of binding the BSSID address of target network.According to the provisions of 802.11 protocol, different wireless networks can have a same network name(i.e. SSID / ESSID), but must correspond to a unique BSSID address (i.e. MAC address). Illegal intruders cancreate a wireless network with the same SSID / ESSID, it will make STAs in the network to join to the illegalAP,thereby and then network leakage happen.Users can preventSTAfrom joining to illegal network by binding the BSSID address, to improve wirelessnetwork security.5.4.5.4.5.4.5.4. UARTUARTUARTUART FrameFrameFrameFrame SchemeSchemeSchemeScheme5.4.1.5.4.1.5.4.1.5.4.1. UARTUARTUARTUART Free-FrameFree-FrameFree-FrameFree-FrameConvert Server support UART free-frame function. If user select open this function, Convert Server will checkthe intervals between any two bytes when rec ei ving UART data. If this interval time exceeds defined value(50ms default), Convert Server will think it as the end of one frame and transfer this free-frame to WiFi port, orConvert Server will receive UART data until 4K bytes, then transfer 4KB frame to WiFi port.Convert Server ’ s default interval time is 50ms. User can also set this interval to fast (10ms) throughATcommand. But user have to consider if user MCU can send UART data with 10ms interval ,or the UART datamay be divide as fragment.Through AT command: AT+FUARTTE=fas t /normal, user can set the interval time: fast (10ms) and normal(50ms). This command is factory default setting command and AT+RELD can ’ t change its value.5.4.2.5.4.2.5.4.2.5.4.2. UARTUARTUARTUART Auto-FrameAuto-FrameAuto-FrameAuto-FrameConvert Server support UART auto-frame function. If user select open this function and setting auto-frametrigger length and auto-frame trigger time parameters, then Convert Server will auto framing the data whichreceived from UART port and transmitting to the network as pre-defined data structure.Auto-frameAuto-frameAuto-frameAuto-frame triggertriggertriggertrigger length:length:length:length: The fixed data length that Convert Server used to transmitting to thenetwork.Auto-frameAuto-frameAuto-frameAuto-frame triggertriggertriggertrigger time:time:time:time: After the trigger time, if UART port received data can ’ t reach auto-frametrigger length, then Convert Server will transmitting available data to the network and bypass theauto-frame trigger length condition.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 21/42 tec@usr.cnDetailed UART auto-frame function can refer to AT+ instruction set “ UARTF/UARTFT/UARTFL ” introduction.5.5.5.5.5.5.5.5. NetworkNetworkNetworkNetwork SettingSettingSettingSettingConvert Server has two TCP/UDP Socket: Socket A and Socket B. Serial data written to the Convert Server ,will be sent to the SocketAand B simultaneously; TCP/UDP data that Convert Server receives through eitherSocketAor B,will be sent to the serial port.Dual Socket through different settings, you can achieve a variety of network interconnect. When the ConvertServer shipped only open Socket A, Socket B default is not to connect, if the user needs to use, please set byATcommands.5.5.1.5.5.1.5.5.1.5.5.1. SocketSocketSocketSocket AAAASocketAhas three work mode: TCP Server, TCP Client, UDP.The setting method, please refer to theAT+NETP command instruction.When SocketAconfigured as TCP Server, it supports Multi-TCP link connection, and maximum 32 TCPclients permitted to connect to Socket A.Multi-TCP link connection will work as following structure:Upstream: All dates from different TCP connection or client will be transmitted to the serial port as asequence.Downstream: All data from serial port (user) will be duplicate and broadcast to every TCP connection orclient.Detailed multi-TCP link data transmition structure as following figure:FigureFigureFigureFigure 7777 Multi-TCPMulti-TCPMulti-TCPMulti-TCP LinkLinkLinkLink DataDataDataData TransmitionTransmitionTransmitionTransmition StructureStructureStructureStructure5.5.2.5.5.2.5.5.2.5.5.2. SocketSocketSocketSocket BBBBSocket B has one work mode: TCP Client, please refer to theAT+ SOCKB command instruction.With variety work mode, socket B can provide users with flexible data transfer methods.For example, SocketB can connect to a remote server in order to achieve remote control.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 22/42 tec@usr.cn5.6.5.6.5.6.5.6. NewNewNewNew functionfunctionfunctionfunctionThis chapter is based on the function of V4.02.10.USR13 and above, if not this version you can skip thissection.5.6.1.5.6.1.5.6.1.5.6.1. TCPTCPTCPTCP passwordpasswordpasswordpassword authenticationauthenticationauthenticationauthenticationThis feature is available only on the Convert Server as a TCP server, when the TCP client connection ConvertServer , the Convert Server will authenticate each connected tcp.Each TCP client first data is the “ password +0x0d+0x0a ” (the password is Webpage authentication password).The default password is “ admin ” , so the first piece of data should be "0x61 0x64 0x6D 0x69 0x6E 0x0D 0x0A"( Hex ). If the password is correct, the Convert Server returns "OK", on the other hand, return to the "NO" anddisconnect.The TCP connection of this function can be Webpage in "TCP connection password authentication" isopened or disable. Please refer to the specific "5.1.2" section.5.6.2.5.6.2.5.6.2.5.6.2. UploadUploadUploadUpload IDIDIDIDThis function only applies to the Convert Server as a TCP client, in front of the data when Convert Serverconnected to the server with two bytes of ID (ID the range is 0 ~ 65535, the high byte before, and the low bytebehind) plus two bytes ID radix-minus-one complement. Convert Server is the default ID is1111,for example,is sent to the server when the first four bytes "0x57 0x04 0xfb 0 xa8".There are two ways to upload their own id: one is to upload their own id for connection to the server for thefirst time;The other is a plus id in front of each data.ID number related parameter is set in the "serial port and other Settings" section of the web, build jointfunction of ID for the first time, and each data with the function of ID are opened by default.ID can also use the at command to set the related parameters, specific refer to 5.2.1.4.32-5.2.1.4.34 section.5.6.3.5.6.3.5.6.3.5.6.3. SSSS elf-adaptionelf-adaptionelf-adaptionelf-adaption BaudrateBaudrateBaudrateBaudrateThis feature, please cooperate with our company's virtual serial port software use.Use a serial port connected Convert Server , and use the at command "at + AABR = on" open this functionand restart.In the USR - VOCM software "synchronous baud rate (RFC2217 similar )" is selected, thefollowing figure .
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 23/42 tec@usr.cnFigureFigureFigureFigure 8888 RFCRFCRFCRFC 2217221722172217In this way, the Convert Server of baud rate will be as the USR-VCOM to change at any time, and don't haveto restart the Convert Server .If restart the Convert Server , baud rate and will come back to before.5.6.4.5.6.4.5.6.4.5.6.4. KeepaliveKeepaliveKeepaliveKeepaliveV4.02.10. USR13 and above version of the firmware added keepalive when the TCP connection mechanism,so when the Convert Server of network anomalies, timely diagnose abnormal to the network and disconnect,when the network has resumed after, and just in time to connect to the server.5.6.5.5.6.5.5.6.5.5.6.5. MultipleMultipleMultipleMultiple STASTASTASTA parametersparametersparametersparametersThis function based on V4.02.10.USR18 and above version of the firmware, in the sta mode, if can networksignal is too low, it will automatically switch to the other AP network (switching network automatically restart).This feature provides a signal threshold, when the current network signals is lower than the critical value, theConvert Server of automatic switching network and restart.If the signal value is set to 100, the Convert Serverwill not switch network.Even if the current network signal is not the current network will always search, notheavy to other networks.The function of the specific Settings page refer to section 4.5.4.5.6.6.5.6.6.5.6.6.5.6.6. WebsocketWebsocketWebsocketWebsocketThis Convert Server can realize the function of the websocket server, allowing serial real-time interaction withthe web Convert Server, replace the previous HTTP GET, POST, corresponding faster.This Convert Serverprovides the corresponding websocket test page for user testing, specific page is as follows:(webPage:10.10.100.254/websocketen.html)
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 24/42 tec@usr.cnFigureFigureFigureFigure 9999 WebsocketWebsocketWebsocketWebsocket PagePagePagePageClick on the "connect" page and then implements a connection, so a serial port with page can send or receivedata from each other.This Convert Server websocket server support 8 client connection at the same time.This function for web applications, and for web users with higher response speed, if you want to customizethe corresponding web page, can connect your company.5.7.5.7.5.7.5.7. PalmodicPalmodicPalmodicPalmodic SignalSignalSignalSignalBase on selected factory default setting, “ Ready ” signal can have two output statuses:Status One: The Convert Server will output “0”after normal boot up. This signal used to judge ifConvert Server finish boot up and ready for application.Status Two: The Convert Server will output “Palmodic Signal ”after normal boot up.The palmodic signalis 0.5Hz square wave with dutyfactor 1:1. User can query this signal to judge if Convert Server is active“live ”or need to re-boot. When Convert Server switches to command mode, it will output “0”, whichused to distinguish work mode and command mode.Notes:This function is user selected factory setting and RELD instruction will not effective for this function. If user notrequires this function, the default factory setting is Status One. Contact with USR Technology for moredetailed support.5.8.5.8.5.8.5.8. ParametersParametersParametersParameters ConfigurationConfigurationConfigurationConfigurationConvert Server Convert Server support s two methods to configuration parameters: WebWebWebWeb AccessingAccessingAccessingAccessing andAT+instructionAT+instructionAT+instructionAT+instruction set.set.set.set.Web accessing means users can configure parameters through built-in webpage. When Convert ServerConvert Server connected to wireless network, parameters configuration is done on a PC connected to the
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 25/42 tec@usr.cnsame wireless network. AT+instruction set configuration means user configure parameters through serialinterface command. Refer to “ AT+instruction set ” chapter for more detail.Notes:Notes:Notes:Notes:USR can customized the parameters setting as customer request and ship Convert Server with theseparameters as factory default configuration. It will reduce user ’ s Convert Server configuration time for massproduction. Also, if user need different parameters setting for every Convert Server , USR can provide theauto-configuration tool to speed up the Convert Server con fi guration duration. Please contact USR technicalinterface to acquire this tool if required.5.9.5.9.5.9.5.9. FirmwareFirmwareFirmwareFirmware UpgradeUpgradeUpgradeUpgradeConvert Server supports firmware upgrade online .6.6.6.6. setupsetupsetupsetup processprocessprocessprocess6.1.6.1.6.1.6.1. ConfigurationConfigurationConfigurationConfiguration viaviaviavia WebWebWebWeb AccessingAccessingAccessingAccessingWhen first use Convert Server s, user may need some configuration. User can connect to Convert Server ’ swireless interface with following default setting information and configure the Convert Server through laptop.Web Access Default SettingParametersParametersParametersParameters DefaultDefaultDefaultDefault SettingSettingSettingSettingSSID USR-WIFI232-A P_xxxxIP Address 10.10.10 0 .254Subnet Mask255.255.255.0User NameadminPassword admin6.1.1.6.1.1.6.1.1.6.1.1. OpenOpenOpenOpen WebWebWebWeb ManagementManagementManagementManagement InterfaceInterfaceInterfaceInterfaceStep 1: Connect laptop to SSID “ USR-WIFI232-AP_xxxx ” of Convert Server via wireless LAN card;Step 2: After wireless connection OK. Open browser and access “ http://10.10.100.254http://10.10.100.254http://10.10.100.254http://10.10.100.254 ” ;Step 3: Then input user name and password in the page as following and click “ OK ” button.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 26/42 tec@usr.cnFigureFigureFigureFigure 10101010 OpenOpenOpenOpen WebWebWebWeb ManagementManagementManagementManagement pagepagepagepageThe Convert Server web management page support English and Chinese language. User can selectlanguage environment at the top right corner and click “ Apply ” button.The main menu include nine pages: “ Quick Configure ” , “ Mode Selection ” , ” AP Interface Setting ” , ”STAInterface Setting ” , ” Application Setting ” , “ Ethernet Setting ” , ’’ HTTPD Client m ode ” , “ WEB IO ” and “ DeviceManagement ” .6.1.2.6.1.2.6.1.2.6.1.2. QuickQuickQuickQuick ConfigureConfigureConfigureConfigureThis page provides users with a method of rapid configuration Convert Server.Users according to the steps toconfigure the parameters and restart the Convert Server page, you can let the Convert Server is normal work,reduced the configuration steps and time.Of course the options on this page is less, if some detailedconfiguration, still need to the corresponding configuration page.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 27/42 tec@usr.cnFigureFigureFigureFigure 11111111 QuickQuickQuickQuick ConfigureConfigureConfigureConfigure PagePagePagePageThis page has four configuration options and a restart, the corresponding instructions below:WI-FI Setting: set the working mode of wifi, AP mode or the STA.Ethernet Ports Setting: open/close the Ethernet ports, and set up the corresponding work mode.UART Setting: set serial port parameters, including baud rate, parity bit, 485 functions and so on.Network Setting: set network parameters, Only TCPA related parameters.Device Management: when after completion of the above parameters are configured, click reset ConvertServer.6.1.3.6.1.3.6.1.3.6.1.3. ModeModeModeMode SelectionSelectionSelectionSelection PagePagePagePageThis page use to setting the wireless networking mode (AP andSTAmode)."Data transmission mode" selection Convert Server working mode are "Transparent Mode", "Serial Commandmode", "GPIO mode" and ”” HTTPD-Client Mode ” .
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 28/42 tec@usr.cnFigureFigureFigureFigure 12121212 ModeModeModeMode SelectionSelectionSelectionSelection PagePagePagePage6.1.4.6.1.4.6.1.4.6.1.4. APAPAPAP InterfaceInterfaceInterfaceInterface SettingSettingSettingSetting PagePagePagePageThis page use to setting the parameters when Convert Server works asAP.FigureFigureFigureFigure 13131313 APAPAPAP InterfaceInterfaceInterfaceInterface SettingSettingSettingSetting PagePagePagePage6.1.5.6.1.5.6.1.5.6.1.5. STASTASTASTA InterfaceInterfaceInterfaceInterface SettingSettingSettingSetting PagePagePagePageThis page use to setting the parameters when Convert Server works as STA.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 29/42 tec@usr.cnSuch as SSID of AP which Convert Server need to connected, and also select the networking type: DHCP orstatic IP address.FigureFigureFigureFigure 14141414STASTASTASTAInterfaceInterfaceInterfaceInterface SettingSettingSettingSetting PagePagePagePage6.1.6.6.1.6.6.1.6.6.1.6. ApplicationApplicationApplicationApplication SettingSettingSettingSetting PagePagePagePageThis page use to setting the parameters of serial port communication, such as UART setting , UARTAutoFrame Setting , Ethernet function ,Device ID setting and high layer network protocol setting which usedsupport serial communication.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 30/42 tec@usr.cnFigureFigureFigureFigure 15151515 ApplicationApplicationApplicationApplication SettingSettingSettingSetting PagePagePagePageNotes:Notes:Notes:Notes:Generally, Network protocols support three modes: TCPTCPTCPTCP ServerServerServerServer ,TCPTCPTCPTCP ClientClientClientClient ,UDPUDPUDPUDP ServerServerServerServer ,UDPUDPUDPUDP ClientClientClientClient .When the Convert Server is configured to UDP server side, the Convert Server will memory the UDP clientend of the last communication, and communication with this UDP client.While the UDP client mode will only
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 31/42 tec@usr.cnwith the targetIPaddress and communication.When set to the TCP Server, do not need to enter the IPaddress.For other Settings, need to fill in the need to connect each otherIPaddress.Fill in port with protocolport number, at the ends of the communication port number must be the same.The Socket B only as a TCP client terminal to communicate with the server.TCP connection password authentication: when the Convert Server in the TCP server mode, passwordauthentication on the TCP client connect to.Note: this verification is only in a Convert Server as a TCP server.After the opening, the TCP client connectedConvert Server , the first data which sent to the Convert Server is password and carriage returns.Thepassword is the password to login page default is "admin".Such as the default when sending the first datashould be "0x61 0x64 0x6D 0x69 0x6E 0x0D 0x0A" (hex) .6.1.7.6.1.7.6.1.7.6.1.7. EthernetEthernetEthernetEthernet SettingSettingSettingSettingThis page is used to set two Ethernet front-end ports of the Convert Server , two Ethernet front-end portscan be open or closed.And so the second can be set to the WAN port to use, this Convert Server can be usedas a secondary router, making it easy for users to network.Specific Settings page is as follows:FigureFigureFigureFigure 16161616 EthernetEthernetEthernetEthernet SettingSettingSettingSetting PagePagePagePage6.1.8.6.1.8.6.1.8.6.1.8. HTTPDHTTPDHTTPDHTTPD ClientClientClientClient ModeModeModeModeThis page sets the HTTP header in the HTTPD Client mode.Include: the address of the server, the server port,request type, protocol header path, Connection, user-agent.HTTPD Client mode support POST, PUT, GET three HTTP request types.Is a POST or PUT request way,serial data can be added to the back of the HTTP header;When the request is a GET, data can be added tothe back of the path in the HTTP header.The specific way of sending data can consult section 4.2.4.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 32/42 tec@usr.cnFigureFigureFigureFigure 17171717 HTTPDHTTPDHTTPDHTTPD ClientClientClientClient ModeModeModeMode PagePagePagePage6.1.9.6.1.9.6.1.9.6.1.9. DeviceDeviceDeviceDevice ManagementManagementManagementManagement PagePagePagePageThis page use to manage Convert Server general setting, such as administrator setting, restart ConvertServer button, restore factory default setting button, and update firmware through webpage.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 33/42 tec@usr.cnFigureFigureFigureFigure 18181818 DeviceDeviceDeviceDevice ManagementManagementManagementManagement PagePagePagePageNotes:Notes:Notes:Notes:Restart module button: When you setting the parameters of different web pages, you will click “ Apply ” buttonto confirm the setting, but the setting take effect only after user click the “ Restart ” button here, the ConvertServer will re-boot up and ref re sh the memory information with new changes.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 34/42 tec@usr.cnAppendixAppendixAppendixAppendix AAAA :::: QuestionsQuestionsQuestionsQuestions andandandand AnswersAnswersAnswersAnswersQ1:Q1:Q1:Q1: HowHowHowHow totototo configureconfigureconfigureconfigure transparenttransparenttransparenttransparent serialserialserialserial portportportport applicationapplicationapplicationapplication (TCP(TCP(TCP(TCP protocol)protocol)protocol)protocol) withwithwithwithtwotwotwotwo ConvertConvertConvertConvert ServerServerServerServer s?s?s?s?Network structure as below figure:Convert Server 1# Setting:Works as AP mode;--See “ Mode Selection Page”LAN IP address: 10.10.100.254;--See “ AP Interface Setting Page”Network Protocal:TCP/Server, Port ID: 8899;-- See “ Application Setting Page”( Convert Server default setting);Convert Server 2# Setting:Works asSTAmode; --See “ Mode Selection Page ”WAN connection type: DHCP or Static IP (For this example:10.10.100.100)--See “ STAInterface Setting Page”Network Protocal:TCP/Client, Port ID: 8899; Application IP address: Convert Server 1#’s LAN IPaddress (10.10.100.254);-- See “ Application Setting Page”Notes:Notes:Notes:Notes: When Convert Server 2# works as STA mode, Convert Server’s WiFi interface works asWAN port. Convert Server ’ s WAN IP address and LAN IP address shall be setting different segment.So, Convert Server 2# ’ s LAN IP address must change to other segment; (For this sample, wechange to 10.10.99.254);--See “ AP Interface Setting Page”USR-WIFI232-602/604/610/ 2User DeviceUARTUSR-WIFI232-602/604/610/ 2UARTAP SSID:USR-WIFI232-AP_xxxxLAN IP:10.10.100.254Net Prot:Tcp ServerProtocol Port:8899STA SSID:USR-WIFI232-AP_xxxxWAN IP:DHCPNet Prot:Tcp client10.10.100.254:8899LAN IP:10.10.99.2541 #2 #User DeviceFigureFigureFigureFigure 19191919 ConfigureConfigureConfigureConfigure TransparentTransparentTransparentTransparent SerialSerialSerialSerial PortPortPortPort ConnectionConnectionConnectionConnection (TCP)(TCP)(TCP)(TCP)
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 35/42 tec@usr.cnQ2:Q2:Q2:Q2: WhereWhereWhereWhere totototo SetSetSetSet WIFIWIFIWIFIWIFI ConvertConvertConvertConvert ServerServerServerServer LANLANLANLAN IPIPIPIP andandandand WANWANWANWAN IPIPIPIP throughthroughthroughthrough WebWebWebWebPagePagePagePage ????USR-WIFI232-D2 Wireless LAN IP address setting see “ AP Interface Setting Page ” as below Figure,FigureFigureFigureFigure 20202020 ConvertConvertConvertConvert ServerServerServerServer LANLANLANLAN IPIPIPIP SettingSettingSettingSettingUSR-WIFI232-D2 Wireless WAN IP address setting see “ STA Interface Setting Page ” as below Figure, Usercan set WAN connection type to DHCP andSTATICIP.FigureFigureFigureFigure 21212121 ConvertConvertConvertConvert ServerServerServerServer WANWANWANWAN IPIPIPIP SettingSettingSettingSettingQ3:Q3:Q3:Q3: HowHowHowHow totototo configureconfigureconfigureconfigure transparenttransparenttransparenttransparent serialserialserialserial portportportport applicationapplicationapplicationapplication (UDP(UDP(UDP(UDP protocol)protocol)protocol)protocol) withwithwithwithtwotwotwotwo ConvertConvertConvertConvert ServerServerServerServer s?s?s?s?Network structure as below figure:Convert Server 1# Setting:Works as AP mode;--See “ Mode Selection Page”LAN IP address: 10.10.100.254;--See “ AP Interface Setting Page”Network Protocal:UDP, Port ID: 8899; Application IP address:10.10.100.100;-- See “ Application Setting Page”Convert Server 2# Setting:Works asSTAmode; --See “ Mode Selection Page ”WAN connection type: Static IP (10.10.100.100)--See “ STA
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 36/42 tec@usr.cnInterface Setting Page”Network Protocal:UDP, Port ID: 8899; Application IP address: Convert Server 1#’s LAN IP address(10.10.100.254);-- See “ Application Setting Page”LAN IP address: 10.10.99.254 (Different net segment with WAN port)--See “ AP Interface Setting Page”USR-WIFI232-602/604/610/ 2User DeviceUARTUSR-WIFI232-602/604/610/ 2UARTAP SSID:USR-WIFI232-AP_xxxxLAN IP:10.10.100.254Net Prot:UDP10.10.100.100:8899STA SSID:USR-WIFI232-AP_xxxxWAN IP:DHCPNet Prot:UDP10.10.100.254:8899LAN IP:10.10.99.2541 #2 #User DeviceFigureFigureFigureFigure 22222222 ConfigureConfigureConfigureConfigure TransparentTransparentTransparentTransparent SerialSerialSerialSerial PortPortPortPort ConnectionConnectionConnectionConnection (UDP)(UDP)(UDP)(UDP)Q4:Q4:Q4:Q4: WhereWhereWhereWhere totototo setsetsetset ConvertConvertConvertConvert ServerServerServerServer networknetworknetworknetwork protocolprotocolprotocolprotocol (TCP/UDP)?(TCP/UDP)?(TCP/UDP)?(TCP/UDP)?USR-WIFI232-D2 network protocol setting see “ Application Setting Page ” as below Figure,Protocol: TCP ServerOnly Port ID required: 8899 (Default)FigureFigureFigureFigure 23232323 ConvertConvertConvertConvert ServerServerServerServer NetworkNetworkNetworkNetwork Protocols:Protocols:Protocols:Protocols: TCP/ServerTCP/ServerTCP/ServerTCP/ServerProtocol: TCP ClientApplication IP address required: it ’ s target TCP server ‘ sIPaddress;Port ID required: 8899 (Default)
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 37/42 tec@usr.cnFigureFigureFigureFigure 24242424 ConvertConvertConvertConvert ServerServerServerServer NetworkNetworkNetworkNetwork Protocol:Protocol:Protocol:Protocol: TCP/ClientTCP/ClientTCP/ClientTCP/ClientProtocol: UDPNo Server/Client selection required;Application IP address required: it ’ s target device ‘ s IP address;Port ID required: 8899 (Default)FigureFigureFigureFigure 25252525 ConvertConvertConvertConvert ServerServerServerServer NetworkNetworkNetworkNetwork Protocol:Protocol:Protocol:Protocol: UDPUDPUDPUDPQ5:Q5:Q5:Q5: HowHowHowHow totototo configureconfigureconfigureconfigure transparenttransparenttransparenttransparent serialserialserialserial portportportport application:application:application:application: TwoTwoTwoTwo ConvertConvertConvertConvertServerServerServerServer ssss allallallall configuredconfiguredconfiguredconfigured asasasasSTASTASTASTAandandandand connectionconnectionconnectionconnection throughthroughthroughthrough AP?AP?AP?AP?Network structure as below figure:Convert Server 1# Setting: ( We use USR-WIFI232-D2 as AP for this example)Works as AP mode and all default setting;Convert Server 2# Setting:Works asSTAmode; --See “ Mode Selection Page ”WAN connection type: Static IP: 10.10.100.100;--See “ STA Interface Setting Page”Network Protocal:TCP/Server, Port ID: 8899;-- See “ Application Setting Page”LAN IP address: 10.10.99.254 (Different net segment with WAN port);--See “ AP Interface Setting Page”Convert Server 3# Setting:Works asSTAmode; --See “ Mode Selection Page ”WAN connection type: Static IP: 10.10.100.101;--See “ STA Interface Setting Page”Network Protocal:TCP/Client, Port ID: 8899; Application IP address: Convert Server 2#’s WAN IPaddress (10.10.100.100);-- See “ Application Setting Page”
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 38/42 tec@usr.cnLAN IP address: 10.10.98.254 (Different net segment with WAN port);--See “ AP Interface Setting Page”User DeviceUARTUSR-WIFI232-602/604/610/ 2UARTUARTSTA SSID:USR-WIFI232-AP_xxxxLAN IP:10.10.99.254WAN IP:10.10.100.100Net Prot:Tcp ServerProtocol Port:8899STA SSID:USR-WIFI232-AP_xxxxWAN IP:10.10.100.101Net Prot:Tcp client10.10.100.100:8899LAN IP:10.10.98.254AP SSID:USR-WIFI232-AP_xxxxLAN IP:10.10.100.254Net Prot:Tcp ServerProtocol Port:8899User DeviceUser DeviceUSR-WIFI232-602/604/610/ 2USR-WIFI232-602/604/610/ 2FigureFigureFigureFigure 26262626 TwoTwoTwoTwo ConvertConvertConvertConvert ServerServerServerServer ssss ConnectionConnectionConnectionConnection ThroughThroughThroughThrough APAPAPAPQ6:Q6:Q6:Q6: HowHowHowHow totototo avoidavoidavoidavoid IPIPIPIP addressaddressaddressaddress conflictionconflictionconflictionconfliction whenwhenwhenwhen applyapplyapplyapply ConvertConvertConvertConvert ServerServerServerServer ????The following address allocation method can avoid the IP address confliction for dynamic and static IPaddress mixed application.Convert Server dynamic IP address range from 100 to 200 for last IP address segment.Such as default IP: 10.10.100.254. When Convert Server works asAP,the IP address ConvertServer can allocate to STA is from 10.10.100.100 to 10.10.100.200;So, if user needs to set static IP for dedicatedSTAinternal network, the available IP address rangecan start from 10.10.100.1 to 10.10.100.99.Q7:Q7:Q7:Q7: PCPCPCPC worksworksworksworks asasasas server,server,server,server, allallallall ConvertConvertConvertConvert ServerServerServerServer ssss worksworksworksworks asasasas datadatadatadata acquisitionacquisitionacquisitionacquisition cardcardcardcardandandandand connectconnectconnectconnect withwithwithwith PC,PC,PC,PC, howhowhowhow totototo configureconfigureconfigureconfigure thisthisthisthis application?application?application?application?Network structure as below figure: Three Convert Server setup 3 TCP links with PC server. Convert Server 1#works as AP and all devices connect to Convert Server 1# through WiFi interface;
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 39/42 tec@usr.cnPC Setting:IP address: 10.10.100.100;Network Protocal:TCP/Server, Port ID: 8899;Convert Server 1# Setting:Works as AP mode;LAN IP address: 10.10.100.254;Network Protocal:TCP/Client, Port ID: 8899; Application IP address:10.10.100.100;Convert Server 2# Setting:Works asSTAmode;WAN connection type: Static IP: 10.10.100.101;Network Protocal:TCP/Client, Port ID: 8899; Application IP address:10.10.100.100;LAN IP address: 10.10.99.254 (Different net segment with WAN port);Convert Server 3# Setting:Works asSTAmode;WAN connection type: Static IP: 10.10.100.102;Network Protocal:TCP/Client, Port ID: 8899; Application IP address:10.10.100.100;LAN IP address: 10.10.98.254 (Different net segment with WAN port);
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 40/42 tec@usr.cnUSR-WIFI232-602/604/610/ 2User DeviceUARTUSR-WIFI232-602/604/610/ 2User DeviceUARTUSR-WIFI232-602/604/610/ 2User DeviceUARTIP:10.10.100.100Net Prot:tcp server,8899STA SSID:USR-WIFI232-AP_xxxxLAN IP:10.10.99.254WAN IP:10.10.100.101Net Prot:tcp client,10.10.100.100:8899STA SSID:USR-WIFI232-AP_xxxxLAN IP:10.10.98.254WAN IP:10.10.100.102Net Prot:tcp client,10.10.100.100:8899AP SSID:USR-WIFI232-AP_xxxxLAN IP:10.10.100.254Net Prot:tcp client,10.10.100.100:8899FigureFigureFigureFigure 27272727 WirelessWirelessWirelessWireless DataDataDataData AcquisitionAcquisitionAcquisitionAcquisition CardCardCardCard SettingSettingSettingSettingQ8:Q8:Q8:Q8: ConvertConvertConvertConvert ServerServerServerServer supportsupportsupportsupport UDPUDPUDPUDP multicast?multicast?multicast?multicast?At present, all the Convert Server does not support UDP multicast function,IP multicast address range is" 224.0.0.0 ~ 239.255.255.255 ” , When setting Convert Server , please don't set this IP section, if set, may causethe Convert Server can't normal start.Q9:ConvertQ9:ConvertQ9:ConvertQ9:Convert ServerServerServerServer operatesoperatesoperatesoperates inininin STASTASTASTA mode,mode,mode,mode, thethethethe PCPCPCPC howhowhowhow totototo getgetgetget thethethethe IPIPIPIPConvertConvertConvertConvert Server?Server?Server?Server?All Convert Server supports UDP search ,they will return to their respectiveIP,MAC, MID, detailed searchprocess is as follows:1. PC via UDP broadcast (broadcast address: xx.xx.xx.255, Port: 48899) sent a password, the defaultpassword is: "HF-A11ASSISTHREAD", the password can be usedATcommands (AT + FASWD) setup,it's Up to 100 bytes.
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 41/42 tec@usr.cn2. After the Convert Server receives a password, if the password is correct, to the address (Unicast, Port:48899) sends local IP address and MAC address and name of the Convert Server .(IP,MAC, MID as10.10.100.254,888 B5D0000E2, guxin).S o you can get to the IP address of the Convert Server .AppendixAppendixAppendixAppendix b:b:b:b: TheTheTheThe FCCFCCFCCFCC statementstatementstatementstatementFCCFCCFCCFCC STATEMENTSTATEMENTSTATEMENTSTATEMENT1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions:(1) This device may not cause harmful interference.(2) This device must accept any interference received, including interference that may causeundesired operation.2. Changes or modifications not expressly approved by the party responsible for compliance couldvoid the user's authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference in a residential installation.This equipment generates uses and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If thisequipment does cause harmful interference to radio or wifi , which can bedetermined by turning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circui t different from that to which the receiver isconnected.Consult the dealer for help.FCCFCCFCCFCC RadiationRadiationRadiationRadiation ExposureExposureExposureExposure StatementStatementStatementStatementThis equipment complies with FCC radiation exposure limits set forth for an uncontrolledenvironment. This equipment should be installed and operated with minimum distance 20cmbetween the radiator & your body .
Convert Server User Manual www.usr iot.c omJinan USR IOT Technology Limited 42/42 tec@usr.cnAppendixAppendixAppendixAppendix cccc :::: ContactContactContactContactCompany: Jinan USR IOT Technology LimitedAddress: 1-728, Huizhan Guoji Cheng, Gaoxin Qu, Jinan, Shandong, ChinaTel:86-531-55507297, 86-531-88826739Web: www.usr iot . comEmail: sales@usr.cn, order@usr.cnAppendixAppendixAppendixAppendix dddd :::: DisclaimerDisclaimerDisclaimerDisclaimerThis document provides information about RS232 /RS485 TO RJ45&WIFI CONVERT SERVER , thisdocument does not grant any license to intellectual property rights. Except the responsibility declared in theproduct sale clause, USR does not assume any other responsibilities. In addition, USR does not make anywarranties for the sale and use of this product, including the suitability of the product for a particular purpose,merchantability or fitness for any patent, copyright or other intellectual property infringement, etc. USR maymake changes to specifications and product descriptions without notice.AppendixAppendixAppendixAppendix eeee :::: UpdateUpdateUpdateUpdate HistoryHistoryHistoryHistory201 4 - 0 1-09 V1.0 created2014-07-24 V2.0 Increase the HTTPD Client model/serial command mode, modify the GPIOmode.Increase the TCP password authentication, Keepalive, Websocket, upload ID, adaptive baud rate, etc.