Johnson Controls GLASWIFI Wireless Thermostat User Manual User guide

Johnson Controls Inc Wireless Thermostat User guide

Contents

User guide

Download: Johnson Controls GLASWIFI Wireless Thermostat User Manual User guide
Mirror Download [FCC.gov]Johnson Controls GLASWIFI Wireless Thermostat User Manual User guide
Document ID3658901
Application IDRWhwaQRUrpQUtNX1HnfCRQ==
Document DescriptionUser guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize134kB (1674998 bits)
Date Submitted2017-11-30 00:00:00
Date Available2018-05-29 00:00:00
Creation Date2017-11-22 12:23:52
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-11-23 09:42:32
Document TitleUser guide
Document CreatorAdobe InDesign CC 2017 (Windows)

Support
If at any point you need assistance, we’re here to help.
Visit glas.johnsoncontrol.com/support for how-to videos and frequently asked questions.
Can’t find what you’re looking for? Give us a call at 1-833-297-4527(GLAS) and our
technical team can walk you through it.
Before you start, download the GLAS app for easy installation.
Included in box
GLAS Thermostat
4 Screws
Wall Plate
4 Drywall Anchors
4 to 5 Wire Adapter
Quick Start Guide
Tools required
Screwdriver
Drill
Level
Compatibility
GLAS is compatible with most 24 VAC heating and cooling systems.
Use the compatibility checker to ensure your system will work with GLAS by going to
glas.johnsoncontrols.com/compatibilitychecker.
Heating
One or two stages
Cooling
One or two stages
Heat Pump
One or two stages with one-or-two stage auxiliary heat
Fan
Single-speed fan
Auxiliary
Humidifier, dehumidifier, or ventilator (including HRV or ERV)
Terminal descriptions
Note: If you have only one R wire, connect to RC.
Note: If you are replacing an existing thermostat, remove any jumper wires between
R and RH or RC and RH.
First stage of cooling or first stage heat pump
Y2
Second stage of cooling command or second stage heat pump
First stage of conventional heating or first stage auxiliary heat for heat pump
systems
W2
Second stage of conventional heating or second stage of auxiliary heat for
heat pump system
Terminal descriptions
Fan
O/B
Heat pump reversing valve (supports both O type and B type)
AUX
Auxiliary - humidifier, dehumidifier, or ventilator
24 VAC Cool
RH
24 VAC Hot
24 VAC Common
IMPORTANT: If your thermostat is built into the wall and connected
to thick wires with wire nuts, or if it is labeled 110, 120, or 240 volts,
you have a high voltage system that is not compatible with the GLAS
Thermostat. Do not connect your thermostat to these high voltage
wires. GLAS is only compatible with 24VAC systems.
WARNING: Risk of Electric Shock.
Disconnect the power supply before making electrical connections.
Contact with components carrying hazardous voltage can cause
electric shock and may result in severe personal injury or death. If you
have any doubts about properly installing the device, please contact
a professional installer.
ADVERTISSEMENT: Risque de décharge électrique.
Débrancher l’alimentation avant de réaliser tout branchement électrique. Tout contact avec des composants conducteurs de tensions
dangereuses risque d’entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. (need translation)
Turn off system power
2. Turn off the power to your heating or
cooling system at your breaker box to
avoid electrocution or shock.
3. If you want to check your system’s power, adjust the temperature on your current
thermostat enough that the system
switches into heating or cooling mode. If
the system does not power on in a few
minutes, it is off.
IMPORTANT: Never work with
live voltage
Check old wiring
4. Remove the front plate of your old thermostat and take a picture of the current
wiring that shows the wire colors and connections. This picture will come in handy
when connecting your new thermostat.
Connect optional 4 to 5 wire adapter
Note: If you have a C-wire, skip to Step 8.
If you do not have a C-wire to power your
thermostat, use the included adapter to
provide power.
5. Remove the cover of your furnace or air
handling unit to access the control board.
Connect the adapter
6. In your HVAC equipment, disconnect
wires from the control board and connect them to the open terminals on the
adapter.
7. Connect the wired terminals on the other side of the adapter back to the control
board. (Mount with a included magnet)
Disconnect your old thermostat
8. Disconnect your old thermostat and
remove the backplate
Note: While disconnecting your old thermostat, use drywall-safe tape to secure the
wires and keep them from falling back into
the wall.
Installing your GLAS
9. Remove the frontplate by pulling the
top of the silver cover towards you.
10. Use a level to dry fit your GLAS and
mark the wall where you plan to hang
the thermostat. Then drill in the drywall
anchors.
11. Pull all of the wires through the back of
the GLAS thermostat.
Attaching your GLAS
12. Loosely attach your GLAS to the wall
using the included screws.
13. Use your level or the level displayed
on the device to straighten the thermostat
and tighten the screws. Do not overtighten.
Wiring your GLAS
14. Use the picture you took of your old wiring as a reference and connect the wires
to the corresponding terminals on your new GLAS. See pages 25-26 for wiring examples.
Note: If you have auxiliary devices, such as a humidifier, dehumidifier, or ventilator,
see pages 27-34 for wiring examples.
Note: You do not need to have a wire for every terminal.
Attach the front plate
15. Make sure any access wire is flush
against the wall and press the front plate
until you hear a click.
Powering on your HVAC system
16. Return to your system switch or breaker box and turn the power back on.
17. Confirm that the detected wiring
shown on the device screen is correct or
tap any terminals incorrectly identified.
18. Follow the instructions on the device
screen to complete the setup for your
HVAC equipment.
WIRING
DIAGRAMS
NOTE: Wire colors are for reference only. Not every installation will have wires of the
same color. If you are unsure on the proper installation of the unit, please contact a
licensed electrician or a professional HVAC installer before attempting to install the
unit.
Traditional Heat
Traditional AC/Heat
HVAC/Auxiliary Device
Self-Powered Auxiliary Device
Furnace-Powered Auxiliary Device
An integrated auxiliary system is built into a furnace or air handler that shares the
same power supply as the rest of the system and only requires a single control wire.
Furnace-Powered Auxiliary Device
2-Wire Auxiliary Device without C Terminal
An auxiliary device that has two terminals with the same label (HUM, DEHUM, or
AUX) and no C terminal requires a relay pack for operation.
1. Connect the relay pack coil between the auxiliary device and C terminal on your
GLAS device.
2. Connect the switch side of the relay pack to the two terminals on the AUX device.
2-Wire Auxiliary Device without C Terminal
2-Wire Auxiliary Device with C Terminal
An auxiliary device with one C terminal that does not require a relay pack for operation.
1. Connect the C terminal of the device to the C terminal on the furnace or air handler.
2. Connect the AUX terminal of your GLAS device to the control terminal on the
auxiliary device.
2-Wire Auxiliary Device with C Terminal
Heat Pump
Dual-Stage Heat
Dual-Stage Traditional AC
Dual-Stage Heat and Traditional AC
Dual-Stage Heat/Dual-Stage AC
Traditional Heat Pump
Dual-Stage Heat Pump
Dual-Stage Heat Pump with Traditional Emergency Heat
Traditional Heat Pump with Dual-Stage Emergency Heat
Traditional Heat Pump with Traditional Emergency Heat
Regulatory information to user
FCC Part 15C
1. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
2. This device complies with Industry Canada’s license-exempt RSSs. Operation is subject
to the following two conditions: (1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil est conforme aux flux RSS exemptés de licence d’Industrie Can-ada. L’opération est soumise aux deux conditions suivantes:
(1) Cet appareil ne doit pas provoquer d’interférence; et
(2) Cet appareil doit accepter toute interférence, y compris les interférences pouvant
entraîner un fonctionnement indésirable de l’appareil.
CAN ICES-3 (B)/NMB-3(B)
RF Safety Statement
· This device complies with the RF safety requirements for Canada and the USA as per
RSS-102 and FCC Part 1.1310, RF Exposure radiation limits for the General Population /
Uncontrolled Exposure.
· This device shall be installed to maintain a separation distance of 20 cm from the general population.
Changes or modifications not expressly approved by Johnson Controls would void your
authority to operate this device.


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Create Date                     : 2017:11:22 12:23:52-06:00
Metadata Date                   : 2017:11:23 09:42:32-05:00
Modify Date                     : 2017:11:23 09:42:32-05:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Instance ID                     : uuid:7e77779b-f547-4ce1-8d90-8744bb427079
Original Document ID            : xmp.did:bd0a2deb-a84e-0048-900d-95516dae3c99
Document ID                     : xmp.id:67607bd6-1e7d-2048-943d-2d4cbc062841
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:9ca8038c-5c6d-004c-bafd-4bd754413ddb
Derived From Document ID        : xmp.did:ee6626ef-e1d5-e148-8cf4-d7aab1ea11ca
Derived From Original Document ID: xmp.did:bd0a2deb-a84e-0048-900d-95516dae3c99
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2017:11:22 12:23:52-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 46
Creator                         : Adobe InDesign CC 2017 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OEJGLASWIFI

Navigation menu