Johnson Controls KONOZ KONOz Smart Hub Thermostat User Manual

LUX Products Corporation KONOz Smart Hub Thermostat

Contents

User Manual

Installaon Manual
Smart Hub
THERMOSTAT
Thank you for inving KONOz into your home. The setup process
is easy. All you need to do is follow these simple steps and you’ll
be on your way to saving energy and making your home even more
comfortable.
LUX Products oers installaon and product videos
Please visit LuxProducts.com/videos or visit our YouTube channel
LUX Products Corporaon.
Note: To contact LUX Technical Support, please call 856.234.8803.
Para ver estas instrucciones en español, por favor visite.
LuxProducts.com/KONOzmanualSP
LuxProducts.com | 3
1. START HERE
Tools Needed
Table of Contents
1. Start Here ......................................................................................2-5
2. Installing KONOz ..........................................................................6-10
3. Operang KONOz ......................................................................11-16
4. Appendix....................................................................................17-19
KONOz
Drill Oponal: Wire Stripper Smart HubPhillips Screwdriver
Baeries
What’s in the box?
Screws Wall Anchors
Trim Plate Wiring Labels
4 | 856.234.8803
This manual is a comprehensive guide for the installaon and wiring
of your KONOz thermostat.
Step 1.1: Turn o the power at the circuit breaker to both
your heang and cooling systems before performing any
wiring.
Step 1.2: Conrm that your heang
and cooling system is powered down by changing the
temperature on your exisng thermostat. The heang
and cooling should not come on but may show the
temperature change on your exisng thermostat.
Note: Your system should not make any noise and you
should not feel any air exing your vents.
Step 1.3: Remove the front of your old thermostat
from its base.
If you see thick black wires, wire nuts, or any
labels that say 120-240VAC or High Voltage, your
system is not compable with KONOz . Please call
LUX Technical Support at 856.234.8803 before proceeding with your
installaon. If you do not see any high voltage labels or wires, you may
connue with the installaon process.
HIGH
VOLTAGE
STOP
LuxProducts.com | 5
Step 1.4: Take a picture of your current wiring layout. The picture can
be used as reference later.
Step 1.5: Use the included wire labels to mark which wire is connected
to each terminal in your old thermostat.
Note: Wiring leer designaons correspond to either a “Heat Pump” or
“Convenonal” system.
Note: A wiring compatability tool is available at
LuxProducts.com/wiring
1. START HERE
6 | 856.234.8803
Wiring
Step 2.1: Idenfy your system conguraon (see wiring diagrams in
appendix). Potenal conguraons include:
System Conguraon Wiring Conguraon
Convenonal: 1H/1C without C-wire Y, G, W1, R
Convenonal: 1H/1C with C-wire Y, G, W1, R, C
Convenonal: 2H/1C without C-wire Y, G, W1, W2, R
Convenonal: 2H/1C with C-wire Y, G, W1, W2, R, C
System Conguraon Wiring Conguraon
Heat Pump: 1H/1C with C-wire Y, G, R, O/B, C
Heat Pump with auxiliary or dual fuel: Y, G, R, O/B, W1, C
If you have only one R wire, please use the RH terminal. If you have a
dierent conguraon other than what is listed above, please call LUX
Technical Support for help with your installaon. If you have a “C wire
then the included baeries are not needed.
Note: If you do not have a C-wire but would rather not use replaceable
baeries, please visit shop.LuxProducts.com/PowerBridge to learn more
about our Lux Power Bridge soluon.
LuxProducts.com | 7
Step 2.2: Verify that each wire has been properly labeled and remove
each wire from its terminal — make sure that they don’t fall into the
wall.
Step 2.3: Remove the mounng screws from the base of the old
thermostat and remove the base from the wall.
Step 2.4: Separate KONOz from its base.
Step 2.5: If you would like to use the trim
plate or wall anchors, you may install them
now.
Step 2.6: Pull the wires from your wall
through the center hole of the KONOz
base. Secure the base to the wall using the
included mounng hardware. Follow the
built in level to ensure that it is straight.
INSTALLATION
2. WIRING
Step 2.4
Step 2.5 Step 2.6
8 | 856.234.8803
Opon 1 - Convenonal (furnace) Systems:
Step 2.7f: Follow the terminal labels
marked “Convenonal” on the thermostat
base. Press the lever and insert each
labeled wire into the top hole of the
corresponding terminal.
Step 2.8f: If you have both an RC and RH wire present, then remove the
red cap next to the reset buon. You can now proceed to step 2.9.
Opon 2 - Heat Pump Systems:
Step 2.7hp: Follow the terminal labels
marked “Heat Pump” on the thermostat base.
Referencing your wiring photo, press the
lever and insert each labeled wire into the top
hole of the corresponding terminal.
If your old thermostat did not have a W1 wire but did have a W2 wire,
insert the W2 wire into the W1 terminal.
Step 2.8hp: If you have both an O wire and a B wire
(i.e. in a Trane system), install the B wire in the “C” terminal.
For more detailed direcons, please see the wiring diagrams in the
appendix or call LUX Technical Support.
CONVENTIONAL C Y1 W2
HEAT PUMP C Y1 O/B
POWER BRIDGE 4
CONVENTIONAL C Y1 W2
HEAT PUMP C Y1 O/B
POWER BRIDGE 4
LuxProducts.com | 9
Wiring
Step 2.9: If you do not have a C-wire, insert the (4)
AA baeries included with your KONOz thermostat
according to their correct polarizaon markings
found on the KONOz.
Securely fasten KONOz onto its base. Once it has
clicked into place, return power to your heang
and cooling system.
Note: If baeries are installed, you must replace all baeries with only
premium brand alkaline baeries at least once every two years.
To replace the baeries, remove the KONOz from its base (ie
disconnecng it from its supply mains) and insert (4) AA premium
brand alkaline baeries. If you discover leaky or damaged baeries, do
not touch the baeries. Leaky or damaged baeries must be handled
with proper safety equipment included safety glasses with side shields,
and neoprene or natural rubber gloves in a well-venlated room.
For disposal of baeries, abide by the local laws and regulaons of your
region. If you are not able to idenfy the applicable rules in your area,
please check the instrucons of the baery manufacturer.
For disposal of KONOz, you must remove baeries prior to disposal.
INSTALLATION
2. WIRING
10 | 856.234.8803
Step 2.11: Aer conrming your system sengs, KONOz
will ask if you would like to connect to a Smart Hub. Select “SET
to establish a connecon with your Smart Hub or select “OFF” to
connect later. For details on how to congure KONOz for your parcular
Smart Hub please visit: LuxProducts.com/KONOzSmartHubSetup
(F) for Furnace or Boiler:
Set the fan type to Gas (most
common), Electric (for systems
without gas or oil), or Boiler (no
fan).
(HP) for Heat Pump:
Set the valve type to O or B - look
at the photo of your wiring to see
your valve type.
First you will need to set your system type:
Step 2.10: Your KONOz is now ready to be congured for your heang
and cooling system. The KONOz will guide you through the inial system
conguraon. Use the knob to change opons and press the knob to
conrm your selecon.
LuxProducts.com | 11
Changing KONOz’s Décor-snap™ Cover
Place right hang on outside edge of the
Décor-snap cover and le hang on the
edge of the KONOz screen. Hold KONOz
in place while gently pulling the decor
snap cover. You will nd important
informaon for Smart Hub setup
including the Zigbee Install Code and
model number.
*Note: Run Schedule will only work if
enabled on Smart Hub.
Press the knob when the thermostat is idle to view the menu.
Rotate the knob to select an opon and press again to conrm.
System Mode Installaon
Sengs
Fan Mode Network
Connecon
Run Schedule System
Preparing
OPERATIONS GUIDE
3. OPERATIONS
Smart Hub
*
12 | 856.234.8803
The operaons guide secon covers the following:
3.1 How to use KONOz
3.2 Reading KONOz’s screen
3.3 Using KONOz throughout the year
3.1 How to use KONOz
KONOz’s knob is the main way for you to control your heang and
cooling systems. Simply press the knob to open a menu or select an
opon. Press and hold the knob at any me to exit a menu and return
to the home screen. In a menu, rotate the knob to cycle through
available opons.
Note: If you are interested in
advanced informaon, the
Installaon Seng Guide can
be found at
LuxProducts.com/KONOzManual
LuxProducts.com | 13
3.2 Reading KONOzs screen
The large number in
the top le shows
your ambient room
temperature.
The small number in the
boom right shows your
set temperature.
The selected system
mode (HEAT, COOL or
OFF) is shown to the right
of the ambient room
temperature.
The acve fan status
is shown by the icon
below the ambient
room temperature. If
it is o, your fan is not
running. If it is on, your
fan is running. Please
note that your fan will
run depending on your
selected fan mode (either
AUTO or ON).
If you see ON under
your system mode, it
means that your system
is acvely heang or
cooling your home.
This icon indicates the
baery levels of the
KONOz.
Note: Replace all four AA
baeries in the KONOz if the
low baery icon or blinking
empty baery icon appears
on your KONOz.
OPERATIONS GUIDE
3. OPERATIONS
This icon shows that
your HVAC system is
preparing to turn on
or o. Please wait for
heang and cooling
to start.
14 | 856.234.8803
Reading KONOzs screen
This icon opens the
system mode menu.
In this menu, you can
set your HVAC system
to OFF, HEAT, or COOL.
Your thermostat will
automacally detect
which modes are
available when you install
your thermostat, so you
may not see all three
opons depending on
your system type.
This icon opens the
fan mode menu. In
this menu, you can set
your fan to AUTO, or
ON. AUTO will run your
fan when your system
is acvely heang or
cooling. ON will run your
fan connuously. If you
set a lter life value in
the installaon sengs,
you’ll be able to check
the remaining life of your
lter in the fan sengs
menu.
This icon opens the
installaon sengs
menu. In this menu, you
can adjust advanced
preferences for special
applicaons. Select the
gear icon, then aer IS
appears on the screen,
select YES to begin the
installaon sengs ow.
For more informaon
about the installaon
sengs, please view the
“Installaon Sengs
Guide”.
LuxProducts.com | 15
This icon opens the Smart Hub network
connecon menu. In this menu, you can choose
to connect or disconnect from your Smart Hub.
Select “SET” to establish a new Smart Hub
connecon. Select “OFF” to temporarily disable
the connecon. Lastly, select “ON” to reconnect
to your Smart Hub. For more informaon
about connecng to a Smart Hub, please view
KONOz’s Smart Hub Setup Guide.
3.3 Using KONOz throughout the year
Cold Weather:
Heat mode is the best seng to use when its
cold out and you won’t need to use your air
condioner. This will make sure that your air
condioner stays idle and that your heater
keeps your home’s temperature above your
chosen set-temperature.
Hot Weather:
Cool mode is the best seng to use when its
hot out and you won’t need to use your heang
system. This will make sure that your heater
stays idle and that your air condioner keeps
your home’s temperature below your chosen
set-temperature.
OPERATIONS GUIDE
3. OPERATIONS
16 | 856.234.8803
Congratulaons!
Installaon is complete and your KONOz is ready to go. Now lets save
some energy and make your home more comfortable.
Personalize your KONOz.
Its more than a thermostat, its décor! Match KONOz to your style by
simply changing the Décor-snap cover. Check out our wide variety of
designer colors and nishes at LuxProducts.com/ShopCovers
Hibiscus
Red Sea
Green Deep
Blue True
White
Midnight
Black
Sky
Blue Sea Mist
Grey Champagne
Gold Paint
It
Driwood
LuxProducts.com | 17
Convenonal System
Notes:
C-wire oponal
The W2 terminal is used for 2 stage heang
If you have both an RH and RC wire, please remove the red cap from the back of
the thermostat
4. APPENDIX
RC
RC
G
G
1
C
C
4
Y1
Y1
W2
O/B
W1
W1
2
RH
RH
3
Conventional
Heat Pump
Power Bridge
Conventional
Heat Pump
Power Bridge
Furnace Thermostat
Fan
Heat (Stage 1)
Heat (Stage 2)
Cool
Transformer
18 | 856.234.8803
Heat Pump System
Notes:
C-wire oponal
The W1 terminal is used for Auxiliary/Emergency heat or on Dual Fuel systems
RC
RC
G
G
1
C
C
4
Y1
Y1
W2
O/B
W1
W1
2
RH
RH
3
Conventional
Heat Pump
Power Bridge
Conventional
Heat Pump
Power Bridge
Fan
AUX/Emer Heat
Changeover Valve
Compressor
Transformer
Heat Pump Thermostat
LuxProducts.com | 19
4. APPENDIX
Technical Informaon:
Disconnecon Means: Type 1B
Polluon Degree: 2
Impulse Voltage: 330V
Automac Acon: 100,000 cycles
Electrical Rang:
-Input: 24V a.c. 60Hz or 4xAA Alkaline baery
-Output: @24V a.c. Max. 1.5A
FCC Part 15C
Warning: Changes or modicaons to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may
cause harmful interference to radio communicaons.
However, there is no guarantee that interference will not occur in a parcular installaon.If this equipment does
cause harmful interference to radio or television recepon, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operaon is subject to the following two condions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operaon. FCC RF Radiaon Exposure Statement
Cauon: To maintain compliance with the FCCs RF exposure guidelines, place the unit at least 20cm from nearby
persons.
RSS-247
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to the following two
condions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
Lexploitaon est autorisée aux deux condions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2)
l’ulisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d’en
compromere le fonconnement.
LUX PRODUCTS CORPORATION
Philadelphia, PA 19112 USA
LuxProducts.com
Designed in Philadelphia.
53620

Navigation menu