Jotron AS L3FFSVR Protective Capsule for S-VDR and EPIRB User Manual tron ny manual

Jotron AS Protective Capsule for S-VDR and EPIRB tron ny manual

Users Manual

Download: Jotron AS L3FFSVR Protective Capsule for S-VDR and EPIRB User Manual tron ny manual
Mirror Download [FCC.gov]Jotron AS L3FFSVR Protective Capsule for S-VDR and EPIRB User Manual tron ny manual
Document ID862600
Application ID7dVJne72cg4qbJw4knTkkQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize66.15kB (826831 bits)
Date Submitted2007-11-01 00:00:00
Date Available2008-03-17 00:00:00
Creation Date2007-10-31 13:31:42
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-10-31 13:34:45
Document Titletron_ny_manual
Document CreatorAcrobat PDFMaker 7.0.7 for Word
Document Author: Hege Brrun

USERS MANUAL
84066_UM_ L-3 FFSVR_B
L-3
FFSVR
EC Declaration of Conformity, available at www.jotron.com
Abbreviations and definitions
BAUD
Transmission rate unit of measurement for binary coded data (bit per second).
BIT
Short form of Binary Digit. The smallest element of data in a binary-coded
value.
BITE
Built in test equipment
bps
Bits Per Second.
CHARACTER STRING
Continuous characters (other than spaces) in a message.
CHECKSUM
The value sent with a binary-coded message to be checked at the receiving end to
verify the integrity of the message.
COSPAS
COsmicheskaya Sistyema Poiska Avariynich Sudov (Space System for the
Search of Vessels in Distress)
CLOCK
A precisely spaced, stable train of pulses generated within an electronic system
to synchronize the timing of digital operations within the system.
DEFAULT
A condition that the navigator assumes automatically if no other condition is
initiated by the operator.
84066_UM_ L-3 FFSVR_B
EPIRB
Emergency Position Indicating Radio Beacon
FRM
Final Recording Medium
GLOBAL POSITIONING SYSTEM (GPS)
The NAVSTAR Global Positioning System, which consists of or- biting
satellites, a network of ground control stations, and user positioning and
navigation equipment. The system has 24 satellites plus 3 active spare satellites
in six orbital planes about 20,200 kilometers above the earth.
GPS
Global Position System
GPS SYSTEM TIME
Time corrected to Universal Time Coordinated (UTC) and used as the time
standard by the user segment of the GPS system.
IEC
International Electro-technical Commission.
IMO
International Maritime Organization
INTERFACE
Electronic circuits that permit the passage of data between different types of
devices; For example, the speed and heading interface circuit permits data from a
speed log and compass to pass to the navigator processor.
ITU
International Telecommunication Union.
LED
Light Emitting Diode.
84066_UM_ L-3 FFSVR_B
LUT
Local User Terminal (Ground Station)
MCC
Mission Control Center
PROCESSOR
The processor circuit card in the console that controls system operations and
computes the positioning/navigation solutions.
RCC
Rescue Coordination Center
SARSAT
Search and Rescue Satellite-Aided Tracking System
SOFTWARE
Values programmed and preloaded into memory. The values represent a
permanent set of instructions for running the automatic functions (computations)
of the navigator.
L-3 SVR
Simplified Voyage Data Recorder
VHF
Very High Frequency -A set of frequencies in the MHz region.
VSWR
Voltage standing wave ratio
84066_UM_ L-3 FFSVR_B
Amendment Record
AMENDMENT
NO.
INCORP.
BY
DATE
PAGE(S)
VERSION
REASON
FOR
CHANGE
ES
30.04.07
44 pages
New product
ES
02.05.07
28,33,37,38
Changed text
10
11
12
13
14
15
84066_UM_ L-3 FFSVR_B
The information in this book has been carefully checked and is believed to be
accurate. However, no responsibility is assumed for inaccuracies.
CAUTION!
This equipment contains CMOS integrated circuits. Observe handling
precautions to avoid static discharges which may damage these devices.
Jotron AS reserves the right to make changes without further notice to any
products or modules described herein to improve reliability, function or design.
Jotron AS does not assume any liability arising out of the application or use of
the described product. Jotron AS is a prime manufacturer of safety equipment
designed for rescue of human lives and their property. For safety equipment to
be effective in line with the design parameters it is important that they are
handled, stowed and maintained in compliance with the manufacturers
instructions.
Jotron AS Cannot be held responsible for any damage caused due to incorrect
use of the equipment or breach of laid down procedures or for failure of any
specific component or other parts of the equipment.
Jotron AS does not take any responsibility for improper
disassembling/assembling of the equipment. We strongly recommend all service
to be done by authorized Jotron agents. In addition to normal service, Jotron AS
agents have the necessary equipment and education to test the operational
functions of the beacon.
84066_UM_ L-3 FFSVR_B
LIST OF CONTENTS
1 GENERAL DESCRIPTION
1.1
EPIRB MODULE
1.1.1
1.1.2
1.1.3
1.1.4
1.1.5
1.2
System description
Signal detection
Distress location determination
Added value in the EPIRB
EPIRB registration
10
10
11
13
14
L-3 FFSVR FINAL RECORDER MEDIUM (FRM)
15
2 TECHNICAL SPECIFICATION
16
3 FUNCTIONAL DESCRIPTION
18
3.1
18
GENERAL
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
Capsule housing
L-3 FFSVR Final Recorder Medium (FRM)
EPIRB module
Battery module
Automatic release bracket, FBR-3
S-VDR Data and Power connections
3.1.6.1 S-VDR Data and Power connector, capsule
3.1.6.2 S-VDR Data and Power connector, bracket
3.1.7
Wiring table S-VDR Data and Power connection
19
19
19
21
21
22
22
23
24
4 INSTALLATION
4.1
4.2
4.3
4.4
4.5
25
MOUNTING BRACKET FBR-3
25
MOUNTING THE FBR-3
26
MOUNTING OF THE CAPSULE INTO THE FBR-3
26
REPLACEMENT AND MOUNTING OF THE HYDROSTATIC RELEASE MECHANISM 27
JUNCTION BOX
28
5 OPERATING INSTRUCTIONS
84066_UM_ L-3 FFSVR_B
31
5.1
5.2
5.3
5.4
5.5
FBR-3 FLOAT FREE BRACKET
MANUAL OPERATION OF EPIRB MODULE
AUTOMATIC OPERATION OF EPIRB MODULE
TESTING THE EPIRB MODULE
OPERATION OF THE FRM
5.5.1
5.6
31
31
32
32
34
Operating software
34
CHANGE OF BATTERY
35
5.6.1
MSC Circ. 1039
5.6.2
Battery disposal
5.6.2.1 Incineration
5.6.2.2 Land filling
5.6.2.3 Recycling
35
36
36
36
36
6 MAINTENANCE AND TROUBLESHOOTING
37
6.1
6.2
37
37
EPIRB MODULE / BATTERY MODULE
TESTING EPIRB MODULE
6.2.1
6.2.2
6.3
MAINTENANCE OF EPIRB
6.3.1
6.4
6.5
Self-test with sea water contacts activated
Self-test with sea water contacts deactivated
37
37
38
EPIRB module error messages
40
TEST OF GPS RECEIVER WITHOUT TRANSMITTERS ACTIVATED
FRM ANNUAL CHECK
41
41
7 NOTES:
42
8 JOTRON AS SERVICE AGENTS
43
84066_UM_ L-3 FFSVR_B
1 GENERAL DESCRIPTION
The Main parts of the Capsule (L-3 FFSVR) are the EPIRB
(EPIRB module) and the Final Storage Medium (FRM module).
The Capsule is developed to meet the regulations and rules for use
on ships, vessels and life rafts in the maritime service. The Capsule
meets the following specifications for S-VDR and 406MHz EPIRB
for use in search and rescue operations at sea:
•
IEC 61996 ed.2
•
IEC 61097-2 ed2
•
IEC 60945
•
C/S T.001
•
IMO MSC.163 (78)
•
IMO A.810 (19)
•
MED 96/98/EC
1.1 EPIRB MODULE
The Capsule is buoyant, and is designed to automatically release and to
automatically activate the EPIRB in case of an emergency where the
Capsule and its bracket is submerged into the sea. The EPIRB can also
be manually operated. One mounting bracket is available to mount it as
an automatic and manual EPIRB. The purpose of the EPIRB is to give
a primary alarm to the search and rescue authorities. The EPIRB gives
an immediate alarm when activated, transmitting the ID of the ship in
distress. The EPIRB will at the same time transmit the position of the
ship. Care must be taken not to activate the EPIRB unless in an
emergency situation, in such cases the user will be held responsible.
For periodic testing a test function is implemented. During the test
cycle the EPIRB does a self-test off the transmitters and the battery
status. No emergency signal is transmitted during the self-test. The
battery of the EPIRB will last for at least 168 hours from activation.
84066_UM_ L-3 FFSVR_B
1.1.1 System description
The COSPAS/SARSAT system was introduced in 1982 as a
worldwide search and rescue system with the help of satellites
covering the earth’s surface. Since the introduction of the system
more than 11200 persons have been rescued by the
COSPAS/SARSAT system. Currently the system consists of 8
different satellites in a polar orbit Constellation. These satellites
cover the entire earth’s surface and receive the emergency signal
from the 406MHz transmitter within the EPIRB. In addition several
geostationary satellites are equipped with a 406MHz transponder.
These satellites are not able to locate the Capsule but will give an
early warning to the rescue forces, minimizing the time from an
emergency occurs till the rescue forces are at the site. Each
emergency EPIRB in the system is programmed with its own
unique code, therefore it is vital that the ships data that is given to
the dealer you obtained your L-3 SVR, is correct. If the EPIRB is
programmed with serial protocol, it is important that the EPIRB is
registered in the database for each country. This database is
normally located in the same country that the ship is registered.
1.1.2 Signal detection
When the EPIRB is activated (manually or automatically) it
transmits on the frequencies 121.5MHz and 406.028MHz.A
homing signal is emitted on 121.5MHz and a burst is transmitted
on 406.028MHz every 50 second after activation. This burst
contains all necessary information about the ships in distress. After
the EPIRB is activated, the next passing satellite will detect the
transmitted signal and relay it to an antenna at a ground station,
called a LUT (Local User Terminal). For the 121.5MHz signal the
satellite must be within line of sight of both the EPIRB and a
10
84066_UM_ L-3 FFSVR_B
ground station. The ground station or LUT has a 2500 km
satellite reception radius centered at the LUT. In areas without
LUT coverage (mostly less populated areas in the southern
hemisphere), signals from the 121.5MHz transmitter will not be
detected by the satellites, only by passing aircraft’s. From the
year 2006,no new satellites will be launched including
121.5MHz receiver, and from the year 2009,satellitedetection of
the 121.5MHz EPIRB is terminated. This is not the case with
the 406MHz transmitter, because the satellites have a memory
unit, which stores the signals for relay to the next available LUT
giving it a truly global coverage. Once the signal is received by
the LUT, it is processed for location and sent to a Mission
Control Center (MCC).The MCC sorts the alert data according
to geographic search and rescue regions and distributes the
information to the appropriate Rescue Co-ordination Center
(RCC), or if outside the national search and rescue area, to the
appropriate MCC that covers the area that the distress signal
was detected. The RCC in turn takes the necessary action to
initiate search and rescue activities.
1.1.3 Distress location determination
The location of the distress signal is determined by taking
measurements of the doppler shift of the EPIRB frequency
when the satellite first approach and then pass the EPIRB. The
actual frequency is heard at the time of closest approach (TCA).
Knowing the position of the satellite and using the received
doppler signal information, it is possible to determine the
location of the Capsule from the satellite at the TCA. At the
LUT, actually two positions are calculated. One is the actual
position (A) and the other is the mirror image (B) position
[FIG.1.1.3]. A second satellite pass confirms the correct
location (A).With the 406MHzsystem the real solution can be
84066_UM_ L-3 FFSVR_B
11
determined on the first pass with a reliability of nearly 90% and
down to an accuracy of less than 5 km (3.1 miles).
Figure 1.1.3, COSPAS/SARSAT Signal detection system
12
84066_UM_ L-3 FFSVR_B
1.1.4 Added value in the EPIRB
The EPIRB module has been designed to operate with the
COSPAS-SARSAT system and will enhance further the lifesaving
capabilities of conventional beacons. An integrated 12 channel GPS
module accepts continuous positional information from the
standard GPS system using 27 satellites providing an accuracy of
approximately 100m.Upon activation of the Capsule in an
emergency situation the positional information is incorporated into
the distress message transmitted to LUT.
The main advantage with integrated GPS in the EPIRB is the rapid
response and positional accuracy providing vital information during
a rescue operation practically eliminating valuable time spent
searching for the distressed. Whenever a distress message
transmitted by the EPIRB is detected by a polar orbit satellite
(LEOSAR) the delayed alert remains the same as for non-GPS
integrated EPIRB`s (max.90 min.), but the position accuracy is
improved considerably from a radius of 5 km. to amazing 100m.
Whenever a distress message transmitted by the EPIRB is detected
by geostationary satellite (GEOSAR) the alert is immediate (max.5
min.), still providing the accurate position of 100m. Please note
that the positional accuracy delay is depending on the actual
protocol used and programmed into the EPIRB and the location of
the emergency. The information is based on the capacity of the
LEOSAR/GEOSAR COSPAS-SARSAT system.
84066_UM_ L-3 FFSVR_B
13
1.1.5 EPIRB registration
Normally the MCC will contact the vessel or the contact person
registered in a shipping register and/or an EPIRB register (Ships
owner, family member etc.) before alerting the RCC. This is to
determine if the alarm from the EPIRB for some reason is a false
alarm, and an expensive rescue operation can be avoided.
Because of this it is important that the ships data is correct in the
shipping register or in the EPIRB database. The Capsule purchased
in some countries will have a registration form attached to it, it is
important that this registration form is completed by the owner and
returned to the place the Capsule was purchased or to the address
specified on the registration form.
Other countries use the already available shipping register to obtain
the necessary information for a vessel in distress, in these countries
the ship is already registered and no registration form is necessary,
however it is vital that the coding of the EPIRB is kept up to date
with data on the ship (nationality, call.sign, etc.), to minimize the
time from an alarm to the start of the search and rescue operation.
Reprogramming the EPIRB can be done at authorized Jotron AS
agents in more than 250 different places throughout the world. If
you are a resident of the United States, you must register this
beacon with the National Oceanic and Atmospheric Administration
(NOAA) using the registration card included with the unit. Fill out
the form and send it to: SARSAT Beacon Registry, NOAASARSAT, E/SP3, FB4, Room 3320, 5200 Auth Road, Suitland,
MD 20746-4304 Vessel owners shall advise NOAA in writing
upon change of vessel or EPIRB ownership. Transfer of EPIRB to
another vessel, or any other change in registration information,
NOAA will provide registrants with proof of registration and
change of registration postcards.
14
84066_UM_ L-3 FFSVR_B
1.2 L-3 FFSVR Final Recorder Medium (FRM)
The L-3 FRM consists of FRM house including Flashdisc. The FRM
is DC powered from the ship via the bracket connector. The data is fed
from the ships S-VDR system to the FRM through the same connector.
When the Capsule leaves the automatic release bracket, all electrically
power and data connections between the ship S-VDR system and the
FRM inside the capsule is broken.
84066_UM_ L-3 FFSVR_B
15
2 TECHNICAL SPECIFICATION
L-3 FFSVR
STANDARDS
ENVIRONMENTAL
IEC 61097-2 ed.2 annex D and EN 60945 ed.4 2002-08
Temperature range
-20°C to +55°C (operating) -40°C to +70°C (storage)
Degree of protection
10 m depth at 5min
GENERAL
External Supply voltage for
Current consumption S-VDR
12 – 30 VDC
0.25 A at 24VDC
Locator lights
Flashing Xenon light
Test light
Test LED
Frequency range
406,028 / 121,5MHz
Programming
IR port, 2400 bit/s.
Operating life EPIRB
168 hours at -20°C
Dimension
L = 570 mm Ø = 188 mm.
Weight
Approx. 3.5 kg
Material housing
Antennas 406.028MHz,
121.5MHz
Antenna GPS
Polycarbonate with 10% glass fiber.
Built in, vertical polarization, omnidir.
Built in GPS patch antenna.
406MHz
Frequency
406.028MHz +2kHz / -5kHz
Output Power
Protocols
5W ± 2dB
MMSI Standard Location (long) Serial EPIRB Standard (long)
Modulation
Phase modulation 1.1 ±0.1rad.
Data Encoding
Bi Phase L.
Stability
Short term: ≤ 2*10-9. Medium term: ≤ 2*10-9. Residual
noise: ≤ 3*10-9.
Bit rate
400 b/s
16
84066_UM_ L-3 FFSVR_B
L-3 FFSVR
121,5MHz TRANSMITTER
Frequency
121.500MHz ± 10ppm.
Output Power
>75mW
Modulation
A9 AM. The modulation starts with a letter V for VDR in
Morse code, then a sweep tone from max 1600Hz to
min 300Hz is transmitted. Sweep range >700Hz, Downward
/ Upward Sweep rate 2-3 Hz.
L-3 FRM
Flash disk
2 Gbyte, 1.7 Gbyte free.
Interface
Ethernet 10BaseT (10Mbit)
Cable length
< 75 m
GPS RECEIVER
Type
Navman Jupiter, 12 channel GPS receiver
Channels.
12 channels
Accuracy
Better than 4 sec. of an arc.
Frequency
1575.42 MHz
MOUNTING BRACKET
Dimensions:
Height: 695 mm, Width: 166 mm, Depth: 112mm
Weight:
4.6 Kg
Hydrostatic release
Hammar H20
Material
Stainless Steel AISI 316 (SIS 2343)
BATTERY MODULE
8 PCs SAFT LSH20 Lithium-Thionyl chloride (Li-SOCL2).
Connected in series and parallel. Fuse in each cell.
84066_UM_ L-3 FFSVR_B
17
3 FUNCTIONAL DESCRIPTION
3.1 GENERAL
L-3 FFSVR Capsule consists of ten parts.
10
Figure 3.1, Cut-through L-3 FFSVR Capsule
18
84066_UM_ L-3 FFSVR_B
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Main EPIRB switch
Antenna board
Upper housing
Equator ring with gasket
EPIRB module
Recovery ring with mounting clips
FRM
Lower housing
Battery module
S-VDR Connector
3.1.1 Capsule housing
The capsule consists of upper and lower house mounted together
with an equator ring with gasket and locking pin.
3.1.2 L-3 FFSVR Final Recorder Medium (FRM)
See chapter 1.2.
3.1.3 EPIRB module
The EPIRB module consists of four printed circuit boards, which
are mounted in the upper housing:
1.
2.
3.
4.
The main board w/GPS patch antenna, Xenon flash and an
indicator LED
Antenna board. (121.5 / 406 MHz)
GPS interface board
GPS receiver
84066_UM_ L-3 FFSVR_B
19
For automatic activation of the EPIRB module, put the capsule in
the upright position into the water, and the transmission starts when
the seawater completes the circuit between the two external
electrodes (sea water contacts).
When the capsule is mounted in the automatic release bracket
mechanism, there is a safety switch in the EPIRB module, a reed
contact activated by a magnet at the FBR-3 bracket, which disables
the seawater contacts. See figure 3.1.5.
If submerged in water, the hydrostatic release mechanism will
release the capsule at a depth of 2-4 meters. The transmission will
start when the circuit between the seawater contacts is closed and
the capsule is out of the bracket.
The EPIRB module may be manually activated with the main
switch, and is then independent of seawater contacts. The EPIRB
module will also operate while placed in the bracket when
manually activated.
The capsule may easily be released from the mounting bracket
manually.
20
84066_UM_ L-3 FFSVR_B
3.1.4 Battery module
The Battery module is feeding the EPIRB module with 7.2VDC
power to keep the EPIRB transmitters active for 168 hours when
activated, and for test sequences.
The battery module consists of eight SAFT LSH20 LithiumThionyl chloride (Li-SOCL2) batteries connected in series and
parallel and is attached inside the lower house.
3.1.5 Automatic release bracket, FBR-3
The FBR-3 bracket is the docking station for the capsule. A
connector and a cable connected to the ships 24VDC power and SVDR data keeps the FRM alive and working when the capsule is in
the bracket.
Hydrostatic release
Magnet
Spring loaded arm
S-VDR connector
Figure 3.1.5, FBR-3 bracket
84066_UM_ L-3 FFSVR_B
21
3.1.6 S-VDR Data and Power connections
3.1.6.1 S-VDR Data and Power connector, capsule
Figure 3.1.6.1, S-VDR female connector in capsule.
22
84066_UM_ L-3 FFSVR_B
3.1.6.2 S-VDR Data and Power connector, bracket
Figure 3.1.6.2, S-VDR male connector in bracket.
84066_UM_ L-3 FFSVR_B
23
3.1.7 Wiring table S-VDR Data and Power connection
Pin
nr
Wire color
inside capsule
Function
Wire color
bracket
and
connection
box
Blue
White
Green
Red
Brown
Green
Yellow
Brown
Pink
Yellow
Ethernet
Tx +
Ethernet
Tx Ethernet
Rx +
Ethernet
Rx + Supply
Grey
Black
GND
24
84066_UM_ L-3 FFSVR_B
4 INSTALLATION
4.1 Mounting bracket FBR-3
The bracket is an automatic release bracket. Not all details are
shown at this picture.
Figure 4.1, Part of FBR-3 bracket with measures
84066_UM_ L-3 FFSVR_B
25
4.2 Mounting the FBR-3
Bolt the unit to the vessel using the mounting holes.
The Float Free Bracket FBR-3 must be connected to the fixed L-3
FFSVR installation
through the junction box according to the connection diagram in
paragraph 3.1.7.
When the Capsule is mounted in the FBR-3 release mechanism, it
operates as a float free automatic unit.
Therefore it is important that the bracket is mounted in a place
where there are no obstructions that can endanger the automatic
release of the beacon.
The location where the bracket is mounted should be as high as
possible on the vessel, protected from environmental conditions
such as direct sea spray, chemicals, oil, exhaust and vibrations. The
location must also be easily accessible for testing and maintenance.
4.3 Mounting of the Capsule into the FBR-3
Strain the spring loaded lower arm with the connector at the lower
part of the bracket.
Place the higher part of the Capsule into the top grip of the bracket
with the main switch facing out. Then push the Capsule into the
bracket and slowly release the lower arm, checking that the
connector pins at the bracket hits the connector holes at the
Capsule. Place the locking bolt into the corresponding holes in the
lower arm, and mount the clamp at the bolt.
26
84066_UM_ L-3 FFSVR_B
4.4 Replacement and mounting of the Hydrostatic Release
Mechanism
The Hydrostatic Release Mechanism must be mounted before the
Capsule is placed into the FBR-3 bracket.
To replace the Hydrostatic Release Mechanism, remove the
Capsule from the bracket:
1. Remove the clamp on the locking bolt on the spring-loaded
lower arm.
2. Remove the locking bolt.
3. Whilst holding the Capsule, strain the spring-loaded lower arm
and gently remove the Capsule from the bracket.
4. Now the H20 unit is accessible. Unscrew the plastic bolt (3)
and remove the unit.
5. Replace the old unit with a new one and tag in expiration date
for 2 more years.
6. Screw the new plastic bolt on. Make sure the distance piece
(4,5,6) is in place on the plastic bolt. Tighten the bolt using handforce only until rubber seal (5) starts to compress.
Replace the Capsule into the bracket, reversing paragraph 1, 2 and
3.
84066_UM_ L-3 FFSVR_B
27
4.5 Junction box
The junction box is connected to the connector on the FBR-3
bracket with a special cable.
All connections to the ships systems are done at the Junction box.
See figure 4.5.a.
The two fuses are for protection of + DC supply and Ground.
The fuses act as short circuit protection and will automatically reset
some minutes after the short circuit is removed.
Ingress protection of Junction box included bushing nipples: IP66
28
84066_UM_ L-3 FFSVR_B
Figure 4.5.a, Junction box with lid removed
84066_UM_ L-3 FFSVR_B
29
Figure 4.5.b, Junction box with measures
30
84066_UM_ L-3 FFSVR_B
5 OPERATING INSTRUCTIONS
5.1 FBR-3 Float Free Bracket
When the capsule is mounted in the FBR-3 bracket release
mechanism, it operates as a float free automatic unit.
5.2 Manual operation of EPIRB module
Figure 5.2, EPIRB Main switch
The manual operation can be done when the capsule is mounted in
the bracket or when the capsule is removed from the bracket.
Break the seal on the main switch and pull the locking pin. Push in
the leftmost part of switch mechanism and the switch will
automatically go to the ON (Emergency) position.
The red indicator lamp and the Xenon flash on the main board will
start operating, indicating that the EPIRB module is active.
84066_UM_ L-3 FFSVR_B
31
NOTE!
The EPIRB module performs a complete self-test before any
emergency signals are transmitted. The Transmitters will start after
approx. 70 seconds. At the same time GPS receiver is started. This
is done to prevent the GPS receiver to start in TEST position.
Turning the switch back to the READY position stops the
transmission. If the Capsule is out of the bracket, make sure the
battery compartment is dry to prevent activation of the seawater
contacts.
5.3 Automatic operation of EPIRB module
When the capsule is removed from the release mechanism and
placed into water it will automatically activate due to the seawater
contacts. Transmission will stop when the capsule is lifted out of
the water, and if necessary dried off.
When placed in the automatic release mechanism the seawater
contacts are disabled.
When the mechanism is reaching a depth of 2-4 meters, the capsule
will be released and transmission will start automatically.
Note!
There is a time delay of approx. 10 seconds of
activation/deactivation with the seawater contact.
5.4 Testing the EPIRB module
To perform the self-test, the Capsule has to be removed from the
bracket.
32
84066_UM_ L-3 FFSVR_B
WARNING
Releasing the Capsule from the bracket will interrupt all
connections between the ships S-VDR system and the FRM
inside the Capsule, and all recordings will be interrupted.
The regulations require the Capsule not to be removed for
more than 10 minutes.
1. Press the spring-loaded switch on top of the Capsule to the TEST
position, see paragraph 5.2. Keep hands and other objects away
from the upper part of the Capsule. (Away from the antenna).
2. A successful test will consist of a series of blinks on the LED
test-indicator, followed by a continuous light and a strobe flash
after app.15 seconds.
3. If the procedure fails to end up with a continuous light, this
indicates a fault in the EPIRB module. (See paragraph 6.2.1).
4. Release the switch and put the Capsule back into the bracket.
What the self-test actually does is first to wait app.15 seconds to
allow the reference oscillator inside the EPIRB module to warm up.
Then a short burst is transmitted by the 121.5MHz transmitter,
while the output level of the transmitter is checked. Finally, a test
signal is transmitted by the 406 transmitter. During this test signal
the battery voltage, output power and frequency is checked. While
testing the 406 MHz transmitter a test message is transmitted. This
test message is coded with a special synchronization code and will
not be detected by the COSPAS/SARSAT satellites. The purpose
of this test message is to control the actual coding of the EPIRB
module. This can be done with the Jotron AS test unit Tron
UNIDEC or another EPIRB tester.
84066_UM_ L-3 FFSVR_B
33
5.5 Operation of the FRM
5.5.1 Operating software
See the Technical manual for information.
34
84066_UM_ L-3 FFSVR_B
5.6 Change of battery
5.6.1 MSC Circ. 1039
If the L-3 FFSVR is the main EPIRB on board the ship, the rules of
MSC CIRC 1039 apply, and the battery must be changed at an
authorized workshop.
If the L-3 FFSVR is the second EPIRB on board the ship,
authorized personnel can change the battery on board.
To change the battery, the lower Capsule Assembly is replaced
with a new one.
1. Remove the clips and the recovery ring around the equator ring.
2. Remove split pin and pull the U-shaped bolt from the
equator ring.
3. Remove the equator belt by pressing it out from the housing.
4. Separate the lower and upper part of the capsule assembly.
5. Unplug the battery connector, the S-VDR connector and the
seawater connector.
6. Check that the new battery is marked with date of expiration.
7. Place the new gasket on the battery housing.
8. Connect the battery connector, the S-VDR connector and the
seawater connector.
9. Replace the upper part, taking care that the gasket is
correctly fitted and taking note of the orientation marks on
the two housings.
10. Replace the equator ring, U-shaped bolt and split pin.
11. Replace the clips and the recovery ring around the equator ring.
12. Perform a Self-test.
84066_UM_ L-3 FFSVR_B
35
5.6.2 Battery disposal
Dispose in accordance with applicable regulations, which vary
from country to country.(In most countries, the thrashing of used
batteries is forbidden and the end-users are invited to dispose them
properly, eventually through non-profit organizations, mandated by
local governments or organized on a voluntary basis by
professionals).Lithium batteries should have their terminals
insulated prior to disposal.
5.6.2.1 Incineration
Incineration should never be performed by battery users but
eventually by trained professionals in authorized facilities with
proper gas and fumes treatment.
5.6.2.2 Land filling
Leachability regulations (mg/l)
Component
Iron
Nickel
Leachability
100
100
EC
limit
EPA
500
Other*
0,5
* applicable to France
5.6.2.3 Recycling
Send to authorized recycling facilities, eventually through licensed
waste carrier.
36
84066_UM_ L-3 FFSVR_B
6 MAINTENANCE AND TROUBLESHOOTING
6.1 EPIRB module / battery module
The EPIRB should be tested and batteries replaced according to
MSC circ.1039. See chapter 5.6.1.
6.2 Testing EPIRB module
6.2.1 Self-test with sea water contacts activated
To perform the self-test with seawater contacts activated, the
capsule has to be removed from the release mechanism. Authorized
personnel should annually test the seawater contacts.
WARNING
Releasing the Capsule from the bracket will interrupt all
connections between the ships S-VDR system and the FRM
inside the Capsule, and all recordings will be interrupted.
The regulations require the Capsule not to be removed for
more than 10 minutes.
Remove the capsule from the release mechanism and go to paragraph
6.2.2.
6.2.2 Self-test with sea water contacts deactivated
Turn the switch to the «TEST» position. The red indicator will start
flashing for approx. 15 sec. This is to allow the internal TCXO
(Temperature Controlled Xtal Oscillator) to be stable.
Then the output power of both transmitters are checked, the battery
voltage and the PLL of the 406 Transmitter.
A complete message on the 406 Frequency is transmitted, with
inverted frame sync.
84066_UM_ L-3 FFSVR_B
37
If all tests are passed there will be one flash in the Xenon bulb, and
the red indicator light will turn on and stay on until the switch is
released.
A successful test will then consist of a series of rapid flashes in the
test indicator, followed by one Xenon flash and continuous light in
the test indicator.
Any other behavior indicates a fault in the EPIRB module.
6.3 Maintenance of EPIRB
WARNING
Releasing the Capsule from the bracket will interrupt all
connections between the ships S-VDR system and the FRM
inside the Capsule, and all recordings will be interrupted.
The regulations require the Capsule not to be removed for
more than 10 minutes.
Every Month:
Perform EPIRB self-test. (See chapter 6.2.1).
What the self-test actually does is to send out a short test signal on
121,5 and 406,028Mhz,testing the output of the transmitter. While
transmitting the test signal, the battery voltage, output power and
phase lock is tested. During the test of the 406Mhz transmitter a
test message is transmitted, this test message is coded with a
special synchronization code and will not be recognized as real
alert by the COSPAS/SARSAT satellites. Carry out visual
inspection for defects on both the Capsule and Bracket. The
Capsule should be easily removed and replaced in the Bracket.
Make sure that the Capsule and Bracket is not painted or otherwise
covered with chemicals, oil, etc. Check the expiry date of the
38
84066_UM_ L-3 FFSVR_B
EPIRB Battery and the Hydrostatic Release Mechanism. Check the
presence of a firmly attached lanyard in good condition and that it
is neatly stowed and is not tied to the vessel or the mounting
bracket. If the L-3 FFSVR is the main EPIRB on board, these rules
must be followed:
Every 12th Month: Perform extended annual test according to
IMO’s MSC/Circ.1040 (Annual testing of 406 MHz satellite
EPIRBs) as required by SOLAS IV/15.9.This test can be carried
out by one of Jotron AS authorized representatives or any other
service provider in possession of a Tron UNIDEC, Tron DEC or
any other Cospas/Sarsat EPIRB tester/decoder.
The test ensures that the EPIRB is within its specifications and
complies with IMO and the COSPAS/SARSAT system.
Documented proof of test or Test Certificate containing test results
and EPIRB data issued by service provider must be kept onboard
for future inspections the next 12 months.
Every 2ndYear:
Hydrostatic Release Mechanism including Plastic Bolt on the Float
Free Brackets must be replaced.(Check expiry date on label).
Every 5thYear:
The EPIRB Battery must be replaced every 5th year, unless
otherwise instructed by the vessel flag state or local
authorities.(Check expiry date on label).
84066_UM_ L-3 FFSVR_B
39
6.3.1 EPIRB module error messages
If the self-test detects a fault in the EPIRB module one or more of
the following indications are shown:
1. Flashing LED for 15 sec. followed by one (1) flash, no Xenon
flash:
Error: Low power on 406 MHz transmitter
2. Flashing LED for 15 sec. followed by two (2) flashes, no Xenon
flash:
Error: Low battery voltage
3. Flashing LED for 15 sec. followed by three (3) flashes, no
Xenon flash:
Error: Low power on 121.5 MHz transmitter
4. Flashing LED for 15 sec. followed by four- (4) flash, no Xenon
flash:
Error: PLL on 406 Transmitter out of lock
5. Five (5) flashes, no Xenon flash:
Error: EPIRB module not programmed or programming not complete
40
84066_UM_ L-3 FFSVR_B
6.4 Test of GPS receiver without transmitters activated
This information is restricted and is included in the Technical
manual only.
6.5 FRM annual check
In accordance with SOLAS Chapter V Regulation 18.8; -the SVDR system shall be subject to an annual performance checks. A
ship required under International rules to carry a functioning
simplified voyage data recorder (S-VDR), and under Paris
Memorandum Port State Control requirements a ship may be
detained if the S-VDR is not functioning properly.
The person carrying out the annual checks should be approved by
the ship’s Flag Administration and show evidence that he has been
authorized by the S-VDR manufacturer to service the particular
make and model of equipment. To act in accordance with the
requirements for bit-error-rate monitoring the status of the FRM
flash disk memory is to be checked during the annual survey to be
specified by the S-VDR manufacturers procedures.
84066_UM_ L-3 FFSVR_B
41
7
NOTES:
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
.............................................................................................................................
42
84066_UM_ L-3 FFSVR_B
8 Jotron AS SERVICE AGENTS
Please look at www.jotron.com for Marine Service Agents.
Jotron Group subsidiary companies:
Jotron (UK) Ltd.
Crosland Park, Off Crowhall Road
Cramlington
Northumberland NE23 1LA
United Kingdom
Tel +44 1670 712000
Fax +44 1670 590265
E-mail
sales@jotron.co.uk
Jotron Asia Pte. Ltd.
Changi Logistics Center
19 Loyang Way #04-26
Singapore 508724
Tel +65 65426350
Fax +65 65429415
E-mail
sales@jotron-asia.com
Jotron USA, Inc.
10645 Richmond Avenue, Suite 140
Houston, TX 77042
USA
Tel +1 713 268 1061
Fax +1 713 268 1062
E-mail
contact.us@jotron-usa.com
84066_UM_ L-3 FFSVR_B
43
This page is left open
44
84066_UM_ L-3 FFSVR_B

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Company                         : Jotron Electronics AS
Source Modified                 : D:20071029121730
Creator Tool                    : Acrobat PDFMaker 7.0.7 for Word
Modify Date                     : 2007:10:31 13:34:45+01:00
Create Date                     : 2007:10:31 13:31:42+01:00
Metadata Date                   : 2007:10:31 13:34:45+01:00
Document ID                     : uuid:ef60ead7-6129-4ad1-ab41-09c6330cf099
Instance ID                     : uuid:6dea71bb-04c0-46a1-be76-0b4d1fb4194b
Version ID                      : 7
Format                          : application/pdf
Title                           : tron_ny_manual
Creator                         : Hege Brrun
Subject                         : 
Headline                        : 
Page Count                      : 44
Page Layout                     : OneColumn
Author                          : Hege Brrun
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VRV-L3FFSVR

Navigation menu