Jotron AS L3FFSVR Protective Capsule for S-VDR and EPIRB User Manual tron ny manual
Jotron AS Protective Capsule for S-VDR and EPIRB tron ny manual
Users Manual
USERS MANUAL 84066_UM_ L-3 FFSVR_B L-3 FFSVR EC Declaration of Conformity, available at www.jotron.com Abbreviations and definitions BAUD Transmission rate unit of measurement for binary coded data (bit per second). BIT Short form of Binary Digit. The smallest element of data in a binary-coded value. BITE Built in test equipment bps Bits Per Second. CHARACTER STRING Continuous characters (other than spaces) in a message. CHECKSUM The value sent with a binary-coded message to be checked at the receiving end to verify the integrity of the message. COSPAS COsmicheskaya Sistyema Poiska Avariynich Sudov (Space System for the Search of Vessels in Distress) CLOCK A precisely spaced, stable train of pulses generated within an electronic system to synchronize the timing of digital operations within the system. DEFAULT A condition that the navigator assumes automatically if no other condition is initiated by the operator. 84066_UM_ L-3 FFSVR_B EPIRB Emergency Position Indicating Radio Beacon FRM Final Recording Medium GLOBAL POSITIONING SYSTEM (GPS) The NAVSTAR Global Positioning System, which consists of or- biting satellites, a network of ground control stations, and user positioning and navigation equipment. The system has 24 satellites plus 3 active spare satellites in six orbital planes about 20,200 kilometers above the earth. GPS Global Position System GPS SYSTEM TIME Time corrected to Universal Time Coordinated (UTC) and used as the time standard by the user segment of the GPS system. IEC International Electro-technical Commission. IMO International Maritime Organization INTERFACE Electronic circuits that permit the passage of data between different types of devices; For example, the speed and heading interface circuit permits data from a speed log and compass to pass to the navigator processor. ITU International Telecommunication Union. LED Light Emitting Diode. 84066_UM_ L-3 FFSVR_B LUT Local User Terminal (Ground Station) MCC Mission Control Center PROCESSOR The processor circuit card in the console that controls system operations and computes the positioning/navigation solutions. RCC Rescue Coordination Center SARSAT Search and Rescue Satellite-Aided Tracking System SOFTWARE Values programmed and preloaded into memory. The values represent a permanent set of instructions for running the automatic functions (computations) of the navigator. L-3 SVR Simplified Voyage Data Recorder VHF Very High Frequency -A set of frequencies in the MHz region. VSWR Voltage standing wave ratio 84066_UM_ L-3 FFSVR_B Amendment Record AMENDMENT NO. INCORP. BY DATE PAGE(S) VERSION REASON FOR CHANGE ES 30.04.07 44 pages New product ES 02.05.07 28,33,37,38 Changed text 10 11 12 13 14 15 84066_UM_ L-3 FFSVR_B The information in this book has been carefully checked and is believed to be accurate. However, no responsibility is assumed for inaccuracies. CAUTION! This equipment contains CMOS integrated circuits. Observe handling precautions to avoid static discharges which may damage these devices. Jotron AS reserves the right to make changes without further notice to any products or modules described herein to improve reliability, function or design. Jotron AS does not assume any liability arising out of the application or use of the described product. Jotron AS is a prime manufacturer of safety equipment designed for rescue of human lives and their property. For safety equipment to be effective in line with the design parameters it is important that they are handled, stowed and maintained in compliance with the manufacturers instructions. Jotron AS Cannot be held responsible for any damage caused due to incorrect use of the equipment or breach of laid down procedures or for failure of any specific component or other parts of the equipment. Jotron AS does not take any responsibility for improper disassembling/assembling of the equipment. We strongly recommend all service to be done by authorized Jotron agents. In addition to normal service, Jotron AS agents have the necessary equipment and education to test the operational functions of the beacon. 84066_UM_ L-3 FFSVR_B LIST OF CONTENTS 1 GENERAL DESCRIPTION 1.1 EPIRB MODULE 1.1.1 1.1.2 1.1.3 1.1.4 1.1.5 1.2 System description Signal detection Distress location determination Added value in the EPIRB EPIRB registration 10 10 11 13 14 L-3 FFSVR FINAL RECORDER MEDIUM (FRM) 15 2 TECHNICAL SPECIFICATION 16 3 FUNCTIONAL DESCRIPTION 18 3.1 18 GENERAL 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 Capsule housing L-3 FFSVR Final Recorder Medium (FRM) EPIRB module Battery module Automatic release bracket, FBR-3 S-VDR Data and Power connections 3.1.6.1 S-VDR Data and Power connector, capsule 3.1.6.2 S-VDR Data and Power connector, bracket 3.1.7 Wiring table S-VDR Data and Power connection 19 19 19 21 21 22 22 23 24 4 INSTALLATION 4.1 4.2 4.3 4.4 4.5 25 MOUNTING BRACKET FBR-3 25 MOUNTING THE FBR-3 26 MOUNTING OF THE CAPSULE INTO THE FBR-3 26 REPLACEMENT AND MOUNTING OF THE HYDROSTATIC RELEASE MECHANISM 27 JUNCTION BOX 28 5 OPERATING INSTRUCTIONS 84066_UM_ L-3 FFSVR_B 31 5.1 5.2 5.3 5.4 5.5 FBR-3 FLOAT FREE BRACKET MANUAL OPERATION OF EPIRB MODULE AUTOMATIC OPERATION OF EPIRB MODULE TESTING THE EPIRB MODULE OPERATION OF THE FRM 5.5.1 5.6 31 31 32 32 34 Operating software 34 CHANGE OF BATTERY 35 5.6.1 MSC Circ. 1039 5.6.2 Battery disposal 5.6.2.1 Incineration 5.6.2.2 Land filling 5.6.2.3 Recycling 35 36 36 36 36 6 MAINTENANCE AND TROUBLESHOOTING 37 6.1 6.2 37 37 EPIRB MODULE / BATTERY MODULE TESTING EPIRB MODULE 6.2.1 6.2.2 6.3 MAINTENANCE OF EPIRB 6.3.1 6.4 6.5 Self-test with sea water contacts activated Self-test with sea water contacts deactivated 37 37 38 EPIRB module error messages 40 TEST OF GPS RECEIVER WITHOUT TRANSMITTERS ACTIVATED FRM ANNUAL CHECK 41 41 7 NOTES: 42 8 JOTRON AS SERVICE AGENTS 43 84066_UM_ L-3 FFSVR_B 1 GENERAL DESCRIPTION The Main parts of the Capsule (L-3 FFSVR) are the EPIRB (EPIRB module) and the Final Storage Medium (FRM module). The Capsule is developed to meet the regulations and rules for use on ships, vessels and life rafts in the maritime service. The Capsule meets the following specifications for S-VDR and 406MHz EPIRB for use in search and rescue operations at sea: • IEC 61996 ed.2 • IEC 61097-2 ed2 • IEC 60945 • C/S T.001 • IMO MSC.163 (78) • IMO A.810 (19) • MED 96/98/EC 1.1 EPIRB MODULE The Capsule is buoyant, and is designed to automatically release and to automatically activate the EPIRB in case of an emergency where the Capsule and its bracket is submerged into the sea. The EPIRB can also be manually operated. One mounting bracket is available to mount it as an automatic and manual EPIRB. The purpose of the EPIRB is to give a primary alarm to the search and rescue authorities. The EPIRB gives an immediate alarm when activated, transmitting the ID of the ship in distress. The EPIRB will at the same time transmit the position of the ship. Care must be taken not to activate the EPIRB unless in an emergency situation, in such cases the user will be held responsible. For periodic testing a test function is implemented. During the test cycle the EPIRB does a self-test off the transmitters and the battery status. No emergency signal is transmitted during the self-test. The battery of the EPIRB will last for at least 168 hours from activation. 84066_UM_ L-3 FFSVR_B 1.1.1 System description The COSPAS/SARSAT system was introduced in 1982 as a worldwide search and rescue system with the help of satellites covering the earth’s surface. Since the introduction of the system more than 11200 persons have been rescued by the COSPAS/SARSAT system. Currently the system consists of 8 different satellites in a polar orbit Constellation. These satellites cover the entire earth’s surface and receive the emergency signal from the 406MHz transmitter within the EPIRB. In addition several geostationary satellites are equipped with a 406MHz transponder. These satellites are not able to locate the Capsule but will give an early warning to the rescue forces, minimizing the time from an emergency occurs till the rescue forces are at the site. Each emergency EPIRB in the system is programmed with its own unique code, therefore it is vital that the ships data that is given to the dealer you obtained your L-3 SVR, is correct. If the EPIRB is programmed with serial protocol, it is important that the EPIRB is registered in the database for each country. This database is normally located in the same country that the ship is registered. 1.1.2 Signal detection When the EPIRB is activated (manually or automatically) it transmits on the frequencies 121.5MHz and 406.028MHz.A homing signal is emitted on 121.5MHz and a burst is transmitted on 406.028MHz every 50 second after activation. This burst contains all necessary information about the ships in distress. After the EPIRB is activated, the next passing satellite will detect the transmitted signal and relay it to an antenna at a ground station, called a LUT (Local User Terminal). For the 121.5MHz signal the satellite must be within line of sight of both the EPIRB and a 10 84066_UM_ L-3 FFSVR_B ground station. The ground station or LUT has a 2500 km satellite reception radius centered at the LUT. In areas without LUT coverage (mostly less populated areas in the southern hemisphere), signals from the 121.5MHz transmitter will not be detected by the satellites, only by passing aircraft’s. From the year 2006,no new satellites will be launched including 121.5MHz receiver, and from the year 2009,satellitedetection of the 121.5MHz EPIRB is terminated. This is not the case with the 406MHz transmitter, because the satellites have a memory unit, which stores the signals for relay to the next available LUT giving it a truly global coverage. Once the signal is received by the LUT, it is processed for location and sent to a Mission Control Center (MCC).The MCC sorts the alert data according to geographic search and rescue regions and distributes the information to the appropriate Rescue Co-ordination Center (RCC), or if outside the national search and rescue area, to the appropriate MCC that covers the area that the distress signal was detected. The RCC in turn takes the necessary action to initiate search and rescue activities. 1.1.3 Distress location determination The location of the distress signal is determined by taking measurements of the doppler shift of the EPIRB frequency when the satellite first approach and then pass the EPIRB. The actual frequency is heard at the time of closest approach (TCA). Knowing the position of the satellite and using the received doppler signal information, it is possible to determine the location of the Capsule from the satellite at the TCA. At the LUT, actually two positions are calculated. One is the actual position (A) and the other is the mirror image (B) position [FIG.1.1.3]. A second satellite pass confirms the correct location (A).With the 406MHzsystem the real solution can be 84066_UM_ L-3 FFSVR_B 11 determined on the first pass with a reliability of nearly 90% and down to an accuracy of less than 5 km (3.1 miles). Figure 1.1.3, COSPAS/SARSAT Signal detection system 12 84066_UM_ L-3 FFSVR_B 1.1.4 Added value in the EPIRB The EPIRB module has been designed to operate with the COSPAS-SARSAT system and will enhance further the lifesaving capabilities of conventional beacons. An integrated 12 channel GPS module accepts continuous positional information from the standard GPS system using 27 satellites providing an accuracy of approximately 100m.Upon activation of the Capsule in an emergency situation the positional information is incorporated into the distress message transmitted to LUT. The main advantage with integrated GPS in the EPIRB is the rapid response and positional accuracy providing vital information during a rescue operation practically eliminating valuable time spent searching for the distressed. Whenever a distress message transmitted by the EPIRB is detected by a polar orbit satellite (LEOSAR) the delayed alert remains the same as for non-GPS integrated EPIRB`s (max.90 min.), but the position accuracy is improved considerably from a radius of 5 km. to amazing 100m. Whenever a distress message transmitted by the EPIRB is detected by geostationary satellite (GEOSAR) the alert is immediate (max.5 min.), still providing the accurate position of 100m. Please note that the positional accuracy delay is depending on the actual protocol used and programmed into the EPIRB and the location of the emergency. The information is based on the capacity of the LEOSAR/GEOSAR COSPAS-SARSAT system. 84066_UM_ L-3 FFSVR_B 13 1.1.5 EPIRB registration Normally the MCC will contact the vessel or the contact person registered in a shipping register and/or an EPIRB register (Ships owner, family member etc.) before alerting the RCC. This is to determine if the alarm from the EPIRB for some reason is a false alarm, and an expensive rescue operation can be avoided. Because of this it is important that the ships data is correct in the shipping register or in the EPIRB database. The Capsule purchased in some countries will have a registration form attached to it, it is important that this registration form is completed by the owner and returned to the place the Capsule was purchased or to the address specified on the registration form. Other countries use the already available shipping register to obtain the necessary information for a vessel in distress, in these countries the ship is already registered and no registration form is necessary, however it is vital that the coding of the EPIRB is kept up to date with data on the ship (nationality, call.sign, etc.), to minimize the time from an alarm to the start of the search and rescue operation. Reprogramming the EPIRB can be done at authorized Jotron AS agents in more than 250 different places throughout the world. If you are a resident of the United States, you must register this beacon with the National Oceanic and Atmospheric Administration (NOAA) using the registration card included with the unit. Fill out the form and send it to: SARSAT Beacon Registry, NOAASARSAT, E/SP3, FB4, Room 3320, 5200 Auth Road, Suitland, MD 20746-4304 Vessel owners shall advise NOAA in writing upon change of vessel or EPIRB ownership. Transfer of EPIRB to another vessel, or any other change in registration information, NOAA will provide registrants with proof of registration and change of registration postcards. 14 84066_UM_ L-3 FFSVR_B 1.2 L-3 FFSVR Final Recorder Medium (FRM) The L-3 FRM consists of FRM house including Flashdisc. The FRM is DC powered from the ship via the bracket connector. The data is fed from the ships S-VDR system to the FRM through the same connector. When the Capsule leaves the automatic release bracket, all electrically power and data connections between the ship S-VDR system and the FRM inside the capsule is broken. 84066_UM_ L-3 FFSVR_B 15 2 TECHNICAL SPECIFICATION L-3 FFSVR STANDARDS ENVIRONMENTAL IEC 61097-2 ed.2 annex D and EN 60945 ed.4 2002-08 Temperature range -20°C to +55°C (operating) -40°C to +70°C (storage) Degree of protection 10 m depth at 5min GENERAL External Supply voltage for Current consumption S-VDR 12 – 30 VDC 0.25 A at 24VDC Locator lights Flashing Xenon light Test light Test LED Frequency range 406,028 / 121,5MHz Programming IR port, 2400 bit/s. Operating life EPIRB 168 hours at -20°C Dimension L = 570 mm Ø = 188 mm. Weight Approx. 3.5 kg Material housing Antennas 406.028MHz, 121.5MHz Antenna GPS Polycarbonate with 10% glass fiber. Built in, vertical polarization, omnidir. Built in GPS patch antenna. 406MHz Frequency 406.028MHz +2kHz / -5kHz Output Power Protocols 5W ± 2dB MMSI Standard Location (long) Serial EPIRB Standard (long) Modulation Phase modulation 1.1 ±0.1rad. Data Encoding Bi Phase L. Stability Short term: ≤ 2*10-9. Medium term: ≤ 2*10-9. Residual noise: ≤ 3*10-9. Bit rate 400 b/s 16 84066_UM_ L-3 FFSVR_B L-3 FFSVR 121,5MHz TRANSMITTER Frequency 121.500MHz ± 10ppm. Output Power >75mW Modulation A9 AM. The modulation starts with a letter V for VDR in Morse code, then a sweep tone from max 1600Hz to min 300Hz is transmitted. Sweep range >700Hz, Downward / Upward Sweep rate 2-3 Hz. L-3 FRM Flash disk 2 Gbyte, 1.7 Gbyte free. Interface Ethernet 10BaseT (10Mbit) Cable length < 75 m GPS RECEIVER Type Navman Jupiter, 12 channel GPS receiver Channels. 12 channels Accuracy Better than 4 sec. of an arc. Frequency 1575.42 MHz MOUNTING BRACKET Dimensions: Height: 695 mm, Width: 166 mm, Depth: 112mm Weight: 4.6 Kg Hydrostatic release Hammar H20 Material Stainless Steel AISI 316 (SIS 2343) BATTERY MODULE 8 PCs SAFT LSH20 Lithium-Thionyl chloride (Li-SOCL2). Connected in series and parallel. Fuse in each cell. 84066_UM_ L-3 FFSVR_B 17 3 FUNCTIONAL DESCRIPTION 3.1 GENERAL L-3 FFSVR Capsule consists of ten parts. 10 Figure 3.1, Cut-through L-3 FFSVR Capsule 18 84066_UM_ L-3 FFSVR_B 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Main EPIRB switch Antenna board Upper housing Equator ring with gasket EPIRB module Recovery ring with mounting clips FRM Lower housing Battery module S-VDR Connector 3.1.1 Capsule housing The capsule consists of upper and lower house mounted together with an equator ring with gasket and locking pin. 3.1.2 L-3 FFSVR Final Recorder Medium (FRM) See chapter 1.2. 3.1.3 EPIRB module The EPIRB module consists of four printed circuit boards, which are mounted in the upper housing: 1. 2. 3. 4. The main board w/GPS patch antenna, Xenon flash and an indicator LED Antenna board. (121.5 / 406 MHz) GPS interface board GPS receiver 84066_UM_ L-3 FFSVR_B 19 For automatic activation of the EPIRB module, put the capsule in the upright position into the water, and the transmission starts when the seawater completes the circuit between the two external electrodes (sea water contacts). When the capsule is mounted in the automatic release bracket mechanism, there is a safety switch in the EPIRB module, a reed contact activated by a magnet at the FBR-3 bracket, which disables the seawater contacts. See figure 3.1.5. If submerged in water, the hydrostatic release mechanism will release the capsule at a depth of 2-4 meters. The transmission will start when the circuit between the seawater contacts is closed and the capsule is out of the bracket. The EPIRB module may be manually activated with the main switch, and is then independent of seawater contacts. The EPIRB module will also operate while placed in the bracket when manually activated. The capsule may easily be released from the mounting bracket manually. 20 84066_UM_ L-3 FFSVR_B 3.1.4 Battery module The Battery module is feeding the EPIRB module with 7.2VDC power to keep the EPIRB transmitters active for 168 hours when activated, and for test sequences. The battery module consists of eight SAFT LSH20 LithiumThionyl chloride (Li-SOCL2) batteries connected in series and parallel and is attached inside the lower house. 3.1.5 Automatic release bracket, FBR-3 The FBR-3 bracket is the docking station for the capsule. A connector and a cable connected to the ships 24VDC power and SVDR data keeps the FRM alive and working when the capsule is in the bracket. Hydrostatic release Magnet Spring loaded arm S-VDR connector Figure 3.1.5, FBR-3 bracket 84066_UM_ L-3 FFSVR_B 21 3.1.6 S-VDR Data and Power connections 3.1.6.1 S-VDR Data and Power connector, capsule Figure 3.1.6.1, S-VDR female connector in capsule. 22 84066_UM_ L-3 FFSVR_B 3.1.6.2 S-VDR Data and Power connector, bracket Figure 3.1.6.2, S-VDR male connector in bracket. 84066_UM_ L-3 FFSVR_B 23 3.1.7 Wiring table S-VDR Data and Power connection Pin nr Wire color inside capsule Function Wire color bracket and connection box Blue White Green Red Brown Green Yellow Brown Pink Yellow Ethernet Tx + Ethernet Tx Ethernet Rx + Ethernet Rx + Supply Grey Black GND 24 84066_UM_ L-3 FFSVR_B 4 INSTALLATION 4.1 Mounting bracket FBR-3 The bracket is an automatic release bracket. Not all details are shown at this picture. Figure 4.1, Part of FBR-3 bracket with measures 84066_UM_ L-3 FFSVR_B 25 4.2 Mounting the FBR-3 Bolt the unit to the vessel using the mounting holes. The Float Free Bracket FBR-3 must be connected to the fixed L-3 FFSVR installation through the junction box according to the connection diagram in paragraph 3.1.7. When the Capsule is mounted in the FBR-3 release mechanism, it operates as a float free automatic unit. Therefore it is important that the bracket is mounted in a place where there are no obstructions that can endanger the automatic release of the beacon. The location where the bracket is mounted should be as high as possible on the vessel, protected from environmental conditions such as direct sea spray, chemicals, oil, exhaust and vibrations. The location must also be easily accessible for testing and maintenance. 4.3 Mounting of the Capsule into the FBR-3 Strain the spring loaded lower arm with the connector at the lower part of the bracket. Place the higher part of the Capsule into the top grip of the bracket with the main switch facing out. Then push the Capsule into the bracket and slowly release the lower arm, checking that the connector pins at the bracket hits the connector holes at the Capsule. Place the locking bolt into the corresponding holes in the lower arm, and mount the clamp at the bolt. 26 84066_UM_ L-3 FFSVR_B 4.4 Replacement and mounting of the Hydrostatic Release Mechanism The Hydrostatic Release Mechanism must be mounted before the Capsule is placed into the FBR-3 bracket. To replace the Hydrostatic Release Mechanism, remove the Capsule from the bracket: 1. Remove the clamp on the locking bolt on the spring-loaded lower arm. 2. Remove the locking bolt. 3. Whilst holding the Capsule, strain the spring-loaded lower arm and gently remove the Capsule from the bracket. 4. Now the H20 unit is accessible. Unscrew the plastic bolt (3) and remove the unit. 5. Replace the old unit with a new one and tag in expiration date for 2 more years. 6. Screw the new plastic bolt on. Make sure the distance piece (4,5,6) is in place on the plastic bolt. Tighten the bolt using handforce only until rubber seal (5) starts to compress. Replace the Capsule into the bracket, reversing paragraph 1, 2 and 3. 84066_UM_ L-3 FFSVR_B 27 4.5 Junction box The junction box is connected to the connector on the FBR-3 bracket with a special cable. All connections to the ships systems are done at the Junction box. See figure 4.5.a. The two fuses are for protection of + DC supply and Ground. The fuses act as short circuit protection and will automatically reset some minutes after the short circuit is removed. Ingress protection of Junction box included bushing nipples: IP66 28 84066_UM_ L-3 FFSVR_B Figure 4.5.a, Junction box with lid removed 84066_UM_ L-3 FFSVR_B 29 Figure 4.5.b, Junction box with measures 30 84066_UM_ L-3 FFSVR_B 5 OPERATING INSTRUCTIONS 5.1 FBR-3 Float Free Bracket When the capsule is mounted in the FBR-3 bracket release mechanism, it operates as a float free automatic unit. 5.2 Manual operation of EPIRB module Figure 5.2, EPIRB Main switch The manual operation can be done when the capsule is mounted in the bracket or when the capsule is removed from the bracket. Break the seal on the main switch and pull the locking pin. Push in the leftmost part of switch mechanism and the switch will automatically go to the ON (Emergency) position. The red indicator lamp and the Xenon flash on the main board will start operating, indicating that the EPIRB module is active. 84066_UM_ L-3 FFSVR_B 31 NOTE! The EPIRB module performs a complete self-test before any emergency signals are transmitted. The Transmitters will start after approx. 70 seconds. At the same time GPS receiver is started. This is done to prevent the GPS receiver to start in TEST position. Turning the switch back to the READY position stops the transmission. If the Capsule is out of the bracket, make sure the battery compartment is dry to prevent activation of the seawater contacts. 5.3 Automatic operation of EPIRB module When the capsule is removed from the release mechanism and placed into water it will automatically activate due to the seawater contacts. Transmission will stop when the capsule is lifted out of the water, and if necessary dried off. When placed in the automatic release mechanism the seawater contacts are disabled. When the mechanism is reaching a depth of 2-4 meters, the capsule will be released and transmission will start automatically. Note! There is a time delay of approx. 10 seconds of activation/deactivation with the seawater contact. 5.4 Testing the EPIRB module To perform the self-test, the Capsule has to be removed from the bracket. 32 84066_UM_ L-3 FFSVR_B WARNING Releasing the Capsule from the bracket will interrupt all connections between the ships S-VDR system and the FRM inside the Capsule, and all recordings will be interrupted. The regulations require the Capsule not to be removed for more than 10 minutes. 1. Press the spring-loaded switch on top of the Capsule to the TEST position, see paragraph 5.2. Keep hands and other objects away from the upper part of the Capsule. (Away from the antenna). 2. A successful test will consist of a series of blinks on the LED test-indicator, followed by a continuous light and a strobe flash after app.15 seconds. 3. If the procedure fails to end up with a continuous light, this indicates a fault in the EPIRB module. (See paragraph 6.2.1). 4. Release the switch and put the Capsule back into the bracket. What the self-test actually does is first to wait app.15 seconds to allow the reference oscillator inside the EPIRB module to warm up. Then a short burst is transmitted by the 121.5MHz transmitter, while the output level of the transmitter is checked. Finally, a test signal is transmitted by the 406 transmitter. During this test signal the battery voltage, output power and frequency is checked. While testing the 406 MHz transmitter a test message is transmitted. This test message is coded with a special synchronization code and will not be detected by the COSPAS/SARSAT satellites. The purpose of this test message is to control the actual coding of the EPIRB module. This can be done with the Jotron AS test unit Tron UNIDEC or another EPIRB tester. 84066_UM_ L-3 FFSVR_B 33 5.5 Operation of the FRM 5.5.1 Operating software See the Technical manual for information. 34 84066_UM_ L-3 FFSVR_B 5.6 Change of battery 5.6.1 MSC Circ. 1039 If the L-3 FFSVR is the main EPIRB on board the ship, the rules of MSC CIRC 1039 apply, and the battery must be changed at an authorized workshop. If the L-3 FFSVR is the second EPIRB on board the ship, authorized personnel can change the battery on board. To change the battery, the lower Capsule Assembly is replaced with a new one. 1. Remove the clips and the recovery ring around the equator ring. 2. Remove split pin and pull the U-shaped bolt from the equator ring. 3. Remove the equator belt by pressing it out from the housing. 4. Separate the lower and upper part of the capsule assembly. 5. Unplug the battery connector, the S-VDR connector and the seawater connector. 6. Check that the new battery is marked with date of expiration. 7. Place the new gasket on the battery housing. 8. Connect the battery connector, the S-VDR connector and the seawater connector. 9. Replace the upper part, taking care that the gasket is correctly fitted and taking note of the orientation marks on the two housings. 10. Replace the equator ring, U-shaped bolt and split pin. 11. Replace the clips and the recovery ring around the equator ring. 12. Perform a Self-test. 84066_UM_ L-3 FFSVR_B 35 5.6.2 Battery disposal Dispose in accordance with applicable regulations, which vary from country to country.(In most countries, the thrashing of used batteries is forbidden and the end-users are invited to dispose them properly, eventually through non-profit organizations, mandated by local governments or organized on a voluntary basis by professionals).Lithium batteries should have their terminals insulated prior to disposal. 5.6.2.1 Incineration Incineration should never be performed by battery users but eventually by trained professionals in authorized facilities with proper gas and fumes treatment. 5.6.2.2 Land filling Leachability regulations (mg/l) Component Iron Nickel Leachability 100 100 EC limit EPA 500 Other* 0,5 * applicable to France 5.6.2.3 Recycling Send to authorized recycling facilities, eventually through licensed waste carrier. 36 84066_UM_ L-3 FFSVR_B 6 MAINTENANCE AND TROUBLESHOOTING 6.1 EPIRB module / battery module The EPIRB should be tested and batteries replaced according to MSC circ.1039. See chapter 5.6.1. 6.2 Testing EPIRB module 6.2.1 Self-test with sea water contacts activated To perform the self-test with seawater contacts activated, the capsule has to be removed from the release mechanism. Authorized personnel should annually test the seawater contacts. WARNING Releasing the Capsule from the bracket will interrupt all connections between the ships S-VDR system and the FRM inside the Capsule, and all recordings will be interrupted. The regulations require the Capsule not to be removed for more than 10 minutes. Remove the capsule from the release mechanism and go to paragraph 6.2.2. 6.2.2 Self-test with sea water contacts deactivated Turn the switch to the «TEST» position. The red indicator will start flashing for approx. 15 sec. This is to allow the internal TCXO (Temperature Controlled Xtal Oscillator) to be stable. Then the output power of both transmitters are checked, the battery voltage and the PLL of the 406 Transmitter. A complete message on the 406 Frequency is transmitted, with inverted frame sync. 84066_UM_ L-3 FFSVR_B 37 If all tests are passed there will be one flash in the Xenon bulb, and the red indicator light will turn on and stay on until the switch is released. A successful test will then consist of a series of rapid flashes in the test indicator, followed by one Xenon flash and continuous light in the test indicator. Any other behavior indicates a fault in the EPIRB module. 6.3 Maintenance of EPIRB WARNING Releasing the Capsule from the bracket will interrupt all connections between the ships S-VDR system and the FRM inside the Capsule, and all recordings will be interrupted. The regulations require the Capsule not to be removed for more than 10 minutes. Every Month: Perform EPIRB self-test. (See chapter 6.2.1). What the self-test actually does is to send out a short test signal on 121,5 and 406,028Mhz,testing the output of the transmitter. While transmitting the test signal, the battery voltage, output power and phase lock is tested. During the test of the 406Mhz transmitter a test message is transmitted, this test message is coded with a special synchronization code and will not be recognized as real alert by the COSPAS/SARSAT satellites. Carry out visual inspection for defects on both the Capsule and Bracket. The Capsule should be easily removed and replaced in the Bracket. Make sure that the Capsule and Bracket is not painted or otherwise covered with chemicals, oil, etc. Check the expiry date of the 38 84066_UM_ L-3 FFSVR_B EPIRB Battery and the Hydrostatic Release Mechanism. Check the presence of a firmly attached lanyard in good condition and that it is neatly stowed and is not tied to the vessel or the mounting bracket. If the L-3 FFSVR is the main EPIRB on board, these rules must be followed: Every 12th Month: Perform extended annual test according to IMO’s MSC/Circ.1040 (Annual testing of 406 MHz satellite EPIRBs) as required by SOLAS IV/15.9.This test can be carried out by one of Jotron AS authorized representatives or any other service provider in possession of a Tron UNIDEC, Tron DEC or any other Cospas/Sarsat EPIRB tester/decoder. The test ensures that the EPIRB is within its specifications and complies with IMO and the COSPAS/SARSAT system. Documented proof of test or Test Certificate containing test results and EPIRB data issued by service provider must be kept onboard for future inspections the next 12 months. Every 2ndYear: Hydrostatic Release Mechanism including Plastic Bolt on the Float Free Brackets must be replaced.(Check expiry date on label). Every 5thYear: The EPIRB Battery must be replaced every 5th year, unless otherwise instructed by the vessel flag state or local authorities.(Check expiry date on label). 84066_UM_ L-3 FFSVR_B 39 6.3.1 EPIRB module error messages If the self-test detects a fault in the EPIRB module one or more of the following indications are shown: 1. Flashing LED for 15 sec. followed by one (1) flash, no Xenon flash: Error: Low power on 406 MHz transmitter 2. Flashing LED for 15 sec. followed by two (2) flashes, no Xenon flash: Error: Low battery voltage 3. Flashing LED for 15 sec. followed by three (3) flashes, no Xenon flash: Error: Low power on 121.5 MHz transmitter 4. Flashing LED for 15 sec. followed by four- (4) flash, no Xenon flash: Error: PLL on 406 Transmitter out of lock 5. Five (5) flashes, no Xenon flash: Error: EPIRB module not programmed or programming not complete 40 84066_UM_ L-3 FFSVR_B 6.4 Test of GPS receiver without transmitters activated This information is restricted and is included in the Technical manual only. 6.5 FRM annual check In accordance with SOLAS Chapter V Regulation 18.8; -the SVDR system shall be subject to an annual performance checks. A ship required under International rules to carry a functioning simplified voyage data recorder (S-VDR), and under Paris Memorandum Port State Control requirements a ship may be detained if the S-VDR is not functioning properly. The person carrying out the annual checks should be approved by the ship’s Flag Administration and show evidence that he has been authorized by the S-VDR manufacturer to service the particular make and model of equipment. To act in accordance with the requirements for bit-error-rate monitoring the status of the FRM flash disk memory is to be checked during the annual survey to be specified by the S-VDR manufacturers procedures. 84066_UM_ L-3 FFSVR_B 41 7 NOTES: ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. ............................................................................................................................. 42 84066_UM_ L-3 FFSVR_B 8 Jotron AS SERVICE AGENTS Please look at www.jotron.com for Marine Service Agents. Jotron Group subsidiary companies: Jotron (UK) Ltd. Crosland Park, Off Crowhall Road Cramlington Northumberland NE23 1LA United Kingdom Tel +44 1670 712000 Fax +44 1670 590265 E-mail sales@jotron.co.uk Jotron Asia Pte. Ltd. Changi Logistics Center 19 Loyang Way #04-26 Singapore 508724 Tel +65 65426350 Fax +65 65429415 E-mail sales@jotron-asia.com Jotron USA, Inc. 10645 Richmond Avenue, Suite 140 Houston, TX 77042 USA Tel +1 713 268 1061 Fax +1 713 268 1062 E-mail contact.us@jotron-usa.com 84066_UM_ L-3 FFSVR_B 43 This page is left open 44 84066_UM_ L-3 FFSVR_B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Company : Jotron Electronics AS Source Modified : D:20071029121730 Creator Tool : Acrobat PDFMaker 7.0.7 for Word Modify Date : 2007:10:31 13:34:45+01:00 Create Date : 2007:10:31 13:31:42+01:00 Metadata Date : 2007:10:31 13:34:45+01:00 Document ID : uuid:ef60ead7-6129-4ad1-ab41-09c6330cf099 Instance ID : uuid:6dea71bb-04c0-46a1-be76-0b4d1fb4194b Version ID : 7 Format : application/pdf Title : tron_ny_manual Creator : Hege Brrun Subject : Headline : Page Count : 44 Page Layout : OneColumn Author : Hege BrrunEXIF Metadata provided by EXIF.tools