Juniper Networks 100 2.4GHz/5GHz Mini-PCI Module for Access Point User Manual Trapeze Regulatory Information
Juniper Networks, Inc. 2.4GHz/5GHz Mini-PCI Module for Access Point Trapeze Regulatory Information
Contents
- 1. User Manual
- 2. Installation Guide
- 3. Regulatory Information
Regulatory Information
Trapeze Regulatory Information Note. Trapeze Regulatory Information is updated frequently. See www.trapezenetworks.com for the most current version. Hardware Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety and Advisory Notice Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Radio Channels and Maximum Transmit Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Regulatory Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Declarations of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Translations of Warnings and Warning Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 The Trapeze Networks Mobility Exchange™ (MX™) switch and Mobility Point™ (MP™) access point must be installed and used in accordance with the documentation provided with these products. In addition to this document, see the following manuals for important safety information: ● Trapeze Mobility Exchange Installation and Basic Configuration Guide ● Trapeze Mobility Point Installation Guide Warning! Installation must be performed by qualified service personnel only. Read and follow all warning notices and instructions marked on the product or included in the documentation. Before installing the product, read the rest of this document. Trapeze Networks, Inc. 5753 W. Las Positas Blvd. Pleasanton, CA 94588 Tel: +1 925-474-2200 Fax: +1 925-251-0642 Toll-Free: 877-FLY-TRPZ (877-359-8779) For the most current version of all documentation see www.trapezenetworks.com Part Number: 730-9502-0018, Revision A Hardware Safety Symbols Hardware Safety Symbols Trapeze Networks Mobility System™ products are labeled with one or more of the following safety symbols: Warning! High voltage. Attention! Refer to the manual. Warning! Class 1 Laser. Protective ground (earth) terminal. Frame or chassis terminal. Direct current (DC). Alternating current (AC). Complies with Underwriters Laboratories regulations in United States and Canada. Complies with European Union (CE) regulations. Contains a radio transmitter that complies with the Radio and Telecommunications Technical Equipment (R&TTE) Directive 1995/5/EC to an unharmonized frequency spectrum. Safety and Advisory Notice Conventions The following safety and advisory notices can appear in Trapeze Networks product documentation: Warning! This situation or condition can cause injury. Warning! High voltage. This situation or condition can cause injury due to electric shock. Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Warning! Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment. Caution! This situation or condition can lead to data loss or damage to the product or other property. Note. This information is of special interest. Radio Channels and Maximum Transmit Power The Mobility Point (MP) access point is designed to meet the Institute for Electrical and Electronics Engineers (IEEE) 802.11 standard for wireless LANs. Table 1 lists the regulatory power limits for each country, frequency, and channel range. Table 1 also indicates whether each country allows use of an MP or external antenna outdoors. For the countries that allow outdoor use, you can install the MP in a Trapeze Networks outdoor MP enclosure with or without an external antenna. Alternatively, you can install an MP indoors and install the external antenna outdoors. (Trapeze external antennas are supported only with model MP-262, for the 802.11b/g radio.) Once you designate a country of operation for the MP access points in your network, by selecting a country code with the RingMaster™ tool suite, Web View application, or the command-line interface (CLI) on the MX switch, the software limits your selection of radio frequency band, operating channels, and transmit power to those permissible in that country, for the combination of radio type, channel, and antenna type you want to use. (In some cases, the maximum power setting allowed by the hardware is lower than the regulatory limit. See “Trapeze Hardware Power Limits” on page 8.) Regulatory Power Limits The maximum transmit power listed in Table 1 on page 4 is the Effective Isotropic Radiated Power (EIRP) and is calculated as follows: Transmit Power – Cable Attenuation + Antenna Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 1. Permissible Radio Frequencies, Channels, and Maximum Transmit Power Outdoor Use Allowed Country Frequency Range (MHz) Channels Maximum Transmit Power (EIRP) Australia 5150 to 5250 36, 40, 44, 48 50 mW (17 dBm) 5250 to 5350 52, 56, 60, 64 50 mW (17 dBm) 5725 to 5825 149, 153, 157, 161 250 mW (24 dBm) 2400 to 2483.5 1 to 11 1000 mW (30 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) Brazil 2400 to 2483.5 1 to 11 100 mW (20 dBm) Canada 5150 to 5250 36, 40, 44, 48 50 mW (17 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5725 to 5825 149, 153, 157, 161 1000 mW (30 dBm) 2400 to 2483.5 1 to 11 1000 mW (30 dBm) 5725 to 5825 149, 153, 157, 161 500 mW (27 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 50 mW (17 dBm) 5250 to 5350 52, 56, 60, 64 50 mW (17 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) Austria Belgium China Czech Republic Denmark Finland Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 1. Permissible Radio Frequencies, Channels, and Maximum Transmit Power (continued) Outdoor Use Allowed Country Frequency Range (MHz) Channels Maximum Transmit Power (EIRP) France 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) Greece 2400 to 2483.5 1 to 13 100 mW (20 dBm) Hong Kong 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) India 2400 to 2483.5 1 to 11 1000 mW (30 dBm) Ireland 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 2418 to 2457 4 to 8 25 mW (14 dBm) Germany Great Britain Hungary Iceland Israel Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 1. Permissible Radio Frequencies, Channels, and Maximum Transmit Power (continued) Outdoor Use Allowed Country Frequency Range (MHz) Channels Maximum Transmit Power (EIRP) Italy 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 34, 38, 42, 46 50 mW (17 dBm) 2400 to 2483.5 1 to 13 50 mW (17 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) Malaysia 2400 to 2483.5 1 to 11 25 mW (14 dBm) Mexico 5150 to 5250 36, 40, 44, 48 50 mW (17 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5725 to 5825 149, 153, 157, 161 1000 mW (30 dBm) 2400 to 2483.5 1 to 11 100 mW (20 dBm) N (1 to 8) Y (9 to 11) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 50 mW (17 dBm) 5250 to 5350 52, 56, 60, 64 250 mW (24 dBm) 5725 to 5825 149, 153, 157, 161 250 mW (24 dBm) 2400 to 2483.5 1 to 11 1000 mW (30 dBm) Japan Liechtenstein Luxembourg Netherlands New Zealand Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 1. Permissible Radio Frequencies, Channels, and Maximum Transmit Power (continued) Outdoor Use Allowed Country Frequency Range (MHz) Channels Maximum Transmit Power (EIRP) Norway 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) Saudi Arabia 2400 to 2483.5 1 to 11 100 mW (20 dBm) Singapore 5150 to 5250 36, 40, 44, 48 100 mW (20 dBm) 5725 to 5825 149, 153, 157, 161 25 mW (14 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 2400 to 2483.5 1 to 13 25 mW (14 dBm) 5725 to 5825 149, 153, 157, 161 10 mW (10 dBm) 2400 to 2483.5 1 to 11 100 mW (20 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) Poland Portugal Slovakia Slovenia South Africa South Korea Spain Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 1. Permissible Radio Frequencies, Channels, and Maximum Transmit Power (continued) Outdoor Use Allowed Country Frequency Range (MHz) Channels Maximum Transmit Power (EIRP) Sweden 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5470 to 5725 100, 104, 108, 112, …140 1000 mW (30 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5150 to 5250 36, 40, 44, 48 200 mW (23 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 2400 to 2483.5 1 to 13 100 mW (20 dBm) 5250 to 5350 56, 60, 64 50 mW (17 dBm) 5725 to 5825 149, 153, 157, 161 250 mW (24 dBm) 2400 to 2483.5 1 to 11 100 mW (20 dBm) Thailand 2400 to 2483.5 1 to 13 25 mW (14 dBm) United Arab Emirates 2400 to 2483.5 1 to 13 100 mW (20 dBm) United States 5150 to 5250 36, 40, 44, 48 50 mW (17 dBm) 5250 to 5350 52, 56, 60, 64 200 mW (23 dBm) 5725 to 5825 149, 153, 157, 161 1000 mW (30 dBm) 2400 to 2483.5 1 to 11 1000 mW (30 dBm) Switzerland Taiwan Trapeze Hardware Power Limits The maximum transmit power you can configure on any Trapeze Networks radio is the maximum allowed for the country in which you plan to operate the radio or one of the following values, if lower: ● ● Radio-specific maximums: ● 802.11a—11 dBm for channel numbers less than or equal to 64, or 10 dBm for channel numbers greater than 64 ● 802.11b—16 dBm for all valid channel numbers ● 802.11g—14 dBm for all valid channel numbers Maximum for the specific combination of country, MP model, radio type, channel, and antenna type— see Table 2 and Table 3. Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 2. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11a Maximum Trapeze Power Setting Country Channels Austria 36, 40, 44, 48 19 Belgium 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 11 52, 56, 60, 64 14 149 11 153, 157, 161 13 China 149, 153, 157, 161 14 Czech Republic 36, 40, 44, 48 19 52, 56, 60, 64 19 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48, 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 Canada Denmark Finland France Germany Great Britain Hong Kong Hungary Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 2. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11a (continued) Maximum Trapeze Power Setting Country Channels Iceland 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 34, 38, 42 16 46 14 36, 40, 44, 48 19 52, 56, 60, 64 19 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 36, 40, 44, 48 19 52, 56, 60, 64 19 Ireland Italy Japan Liechtenstein Luxembourg Netherlands Norway Poland Portugal Slovakia Slovenia 10 Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 2. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11a (continued) Maximum Trapeze Power Setting Country Channels South Africa 36, 40, 44, 48 19 52, 56, 60, 64 19 South Korea 149, 153, 157, 161 10 Sweden 36, 40, 44, 48 19 52, 56, 60, 64 19 100, 104, 108, 112, …140 17 36, 40, 44, 48 19 52, 56, 60, 64 19 36, 40, 44, 48 11 52, 56, 60, 64 14 149 11 153, 157, 161 13 Switzerland United States Table 3. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11b/g Maximum Trapeze Power Setting Country Channels Internal Antenna External Antenna 120° 60° Austria Belgium Canada China 180° 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 17 15 10 13 12 11 12 2 to 10 17 15 15 14 15 14 15 14 11 16 14 10 12 10 10 1 to 13 16 16 — — — — — — Trapeze Regulatory Information 11 Radio Channels and Maximum Transmit Power Table 3. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11b/g (continued) Maximum Trapeze Power Setting Country Channels Internal Antenna External Antenna 120° 60° 180° 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 Hong Kong 1 to 13 16 14 — — — — — — Hungary 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 Czech Republic Denmark Finland France Germany Great Britain Greece Iceland 12 Trapeze Regulatory Information Radio Channels and Maximum Transmit Power Table 3. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11b/g (continued) Maximum Trapeze Power Setting Country Channels Internal Antenna External Antenna 120° 60° 180° 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 Israel 4 to 8 14 14 — — — — — — Italy 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 17 14 17 14 16 14 16 14 2 to 12 16 14 17 14 16 14 17 14 13 16 14 17 14 17 14 17 14 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 Malaysia 1 to 11 14 14 — — — — — — Netherlands 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 Ireland Japan Liechtenstein Luxembourg Norway Poland Trapeze Regulatory Information 13 Radio Channels and Maximum Transmit Power Table 3. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11b/g (continued) Maximum Trapeze Power Setting Country Channels Internal Antenna External Antenna 120° 60° 180° 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 South Africa 1 to 13 14 14 — — — — — — South Korea 1 to 11 18 18 — — — — — — Spain 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 16 14 10 12 13 14 14 15 2 to 12 16 14 10 12 13 14 13 15 13 16 14 13 12 15 13 16 Portugal Saudi Arabia Slovakia Slovenia Sweden Switzerland United Arab Emirates 14 Trapeze Regulatory Information Regulatory Compliance Information Table 3. Trapeze Hardware Power Limits—MP Model MP-2xx, 802.11b/g (continued) Maximum Trapeze Power Setting Country Channels Internal Antenna External Antenna 120° 60° United States 180° 17 15 10 13 12 11 12 2 to 10 17 15 15 14 15 14 15 14 11 16 14 10 12 10 10 Regulatory Compliance Information Trapeze Networks products cause no electromagnetic interference to other devices if installed and operated properly and without modification. Modification Prohibition Caution! The Part 15 radio device in the access point operates on a noninterference basis with other devices operating at the same frequency. Any modification to this device not expressly approved by Trapeze Networks can void your authority to operate the device. The manufacturer, Trapeze Networks, is not responsible for any interference caused by unauthorized modification of the devices included with this product, or the substitution or attachment of connecting cables or equipment other than supplied by Trapeze Networks. The correction of interference caused by such unauthorized modification, substitution, or attachment is your responsibility. Trapeze Networks and its authorized resellers or distributors are not liable for any damage or violation of government regulations that might arise from failure to comply with these guidelines. Wiring Notice Note. Other than the power cord, the wiring interconnecting these units is designed to be used intra-building only. Trapeze Regulatory Information 15 Regulatory Compliance Information Federal Communications Commission Notice (United States) This device uses, generates, and radiates radio frequency energy. The radio frequency energy produced by this device is well below the maximum exposure allowed by the Federal Communications Commission (FCC). Operation is subject to the following conditions: ● This device may not cause harmful interference. ● This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits of a Class B or Class A (as marked) digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This accepted equipment is designed and tested to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed in accordance with the instruction manual, may cause harmful interference. There is no guarantee that interference will not occur. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures: ● Reorient or relocate the device to reorient or relocate the receiving antenna. ● Increase separation between the equipment and receiver. Canadian Department of Communications Industry Canada Notice (Canada) This digital apparatus meets the requirements of Canadian Interference-Causing Equipment Regulation RSS-210. Cet appareil respecte les exigences du Reglement sur le material broilleur du Canada. This device complies with the limits of Industry Canada (IC). Operation is subject to the following conditions: ● This device may not cause harmful interference. ● This device must accept any interference received, including interference that may cause undesired operation. The device is certified to the requirements of IC RSS-139-1. The use of this device in a system operating either partially or completely outdoors may require the user to obtain a license for the system. For more information, contact your local Industry Canada office. 16 Trapeze Regulatory Information Regulatory Compliance Information Radio Frequency Compliance Information (European Union) The MP access point has been tested and found to comply with European Telecommunications Standard (ETS) 300 328 for 2.4-GHz equipment and ETS 301 893 for 5-GHz equipment. These standards cover wideband data transmission systems referred to in European Conference of Postal and Telecommunications Administrations (CEPT) recommendation T/R 10.01. Voluntary Control Council for Interference by Information Technology Equipment Notice (Japan) Translation: This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Trapeze Regulatory Information 17 Regulatory Compliance Information Regulatory Compliance Notice (Korea) 18 Trapeze Regulatory Information Declarations of Conformity Lithium Battery Caution The MX switch contains a lithium battery. If you need to replace the battery, make sure you dispose of the battery properly according to local regulations and replace the battery only with another comparable lithium battery. Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. Attentie! Gevaar voor explosie als accu wordt vervangen door onjuist type. Verwijder gebruikte accu's in overeenstemming met de instructies. Vorsicht! Wenn die Batterie durch einen falschen Typ ersetzt wird, besteht das Risiko einer Explosion. Entsorgen Sie die gebrauchten Batterien entsprechend den Anweisungen. Attention ! Risque d'explosion si la batterie est remplacée par une batterie non conforme. Jetez les batteries usagées selon les instructions. ¡Precaución! Peligro de explosión si la bateria es reemplazada con otra de tipo incorrecto. Deseche las baterias usadas siguiendo las instrucciones. Advarsel! Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Declarations of Conformity The following sections contain declarations of conformity. European Union Notice All products labeled with the CE marking comply with the Electromagnetic Compliance (EMC) Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms (ENs). The equivalent international standards are listed in parentheses. ● EN 55022 (CISPR 22)—Electromagnetic Interference ● EN 55024 (IEC 61000-4-2, -3, -4, -5, -6, -8, -11)—Electromagnetic Immunity ● EN 61000-3-2 (IEC 610000-3-2)—Power Line Harmonics Trapeze Regulatory Information 19 Declarations of Conformity ● EN 61000-3-3 (IEC 610000-3-3)—Power Line Flicker ● EN 60 950 (IEC 60950)—Product Safety Products labeled with the CE alert marking contain a radio transmitter that complies with the Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive 1999/ 5/EC to an unharmonized frequency spectrum, issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms (ENs). Where applicable, the equivalent international standards are listed in parentheses. ● EN 60 950 (IEC 60950)—Product Safety ● EN 300 328—Technical Requirements for Radio Equipment ● ETS 300 826 and ETS 301 489-17—General EMC requirements for radio equipment ● ETS 301 893—Broadband Radio Access Networks (BRAN) ● HiperLAN/2 ● Harmonized EN covering essential requirements of Article 3.2 of the R&TTE Directive— Point-to-multipoint digital fixed radio systems and antennas To determine the type of transmitter, check the identification label on your product. European Community, Switzerland, Norway, Iceland, and Liechtenstein Declarations Table 4 lists European declarations of conformity with Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC. Table 4. 20 European Declarations of Conformity with R&TTE Directive 1999/5/EC Language Declaration Statement English This equipment complies with the essential requirements and other relevant provisions of Directive 1999/5/EC. Deutsch Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie 1999/5/EU. Dansk Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF. ¢EllhnaV AutoV o exoplismoV summorjwnetai me tiV ousiwdeiV apaithseiV kai tiV loipeV diataxeiV thV OdhgiaV 1999/5/EK. Español Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC. Trapeze Regulatory Information Declarations of Conformity Table 4. European Declarations of Conformity with R&TTE Directive 1999/5/EC (continued) Language Declaration Statement Français Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC. Íslenska Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB. Italiano Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC. Nederlands Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC. Norsk Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC. Português Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC. Suomalainen Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen. Svenska Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC. Trapeze Regulatory Information 21 Translations of Warnings and Warning Conventions Translations of Warnings and Warning Conventions The following warning(s) and warning conventions apply to this document. Qualified Service Personnel Warning Warning! Installation must be performed by qualified service personnel only. Read and follow all warning notices and instructions marked on the product or included in the documentation. Before installing the product, read the rest of this document. Waarschuwing! De installatie mag alleen worden uitgevoerd door bevoegd onderhoudspersoneel. Het is essentieel dat u kennis neemt van alle waarschuwingen en instructies aangebracht op het product zelf en/of opgenomen in de documentatie. Voordat u het product installeert, dient u dit document in zijn geheel te hebben gelezen. Warnung! Die Installation darf nur von einem qualifizierten Kundendienstmitarbeiter vorgenommen werden. Lesen Sie alle Warnhinweise und Anweisungen auf dem Produkt oder in der Dokumentation und befolgen Sie sie. Bevor Sie das Produkt installieren, sollten Sie dieses Dokument vollständig lesen. Avertissement ! L’installation doit être effectuée uniquement par des techniciens qualifiés. Lisez et suivez toutes les notices d’avertissement et les instructions figurant sur le produit ou comprises dans la documentation. Lisez le reste de ce document avant d’installer ce produit. Aviso Sólo puede realizar la instalación personal cualificado de asistencia técnica. Lea y siga todas las notas de advertencia e instrucciones indicadas en el producto o incluidas en la documentación. Antes de instalar el producto, lea el resto de este documento. Warning Conventions Warning! This situation or condition can cause injury. Waarschuwing! Deze situatie of omstandigheid kan letsel veroorzaken. Warnung! Diese Situation oder dieser Zustand kann zu Verletzungen führen. Avertissement ! Cette situation ou cette condition peuvent provoquer des blessures. Aviso Esta situación o condición puede causar lesiones. 22 Trapeze Regulatory Information Translations of Warnings and Warning Conventions Warning! High voltage. This situation or condition can cause injury due to electric shock. Waarschuwing! Hoog voltage. Deze situatie of omstandigheid kan letsel veroorzaken door elektrische schokken. Warnung! Hochspannung. Diese Situation oder dieser Zustand kann einen Elektroschock verursachen. Avertissement ! Haute tension. Cette situation ou cette condition peuvent provoquer des blessures dues à des décharges électriques. Aviso Alta tensión. Esta situación o condición puede causar lesiones por descarga eléctrica. Warning! Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment. Waarschuwing! Straling. Deze situatie of omstandigheid kan letsel veroorzaken door onjuist gebruik van glasvezelapparatuur. Warnung! Strahlung. Diese Situation oder dieser Zustand kann durch falschen Umgang mit glasfaserbasierten Geräten zu Verletzungen führen. Avertissement ! Radiation. Cette situation ou cette condition peuvent provoquer des blessures dues à une manipulation inappropriée d’appareils équipés de fibres optiques. Aviso Radiación. Esta situación o condición puede causar lesiones debido a un manejo inadecuado del equipamiento de fibra óptica. Trapeze Regulatory Information 23 Translations of Warnings and Warning Conventions © 2004 Trapeze Networks, Inc. All rights reserved. Trapeze Networks, the Trapeze Networks logo, the Trapeze Networks flyer icon, Mobility System, Mobility Exchange, MX, Mobility Domain, Mobility Profile, Mobility Point, MP, Mobility System Software, MSS, RingMaster, SentrySweep, Trapeze Access Point Access Protocol, and TAPA are trademarks of Trapeze Networks, Inc. All other products and services are trademarks, registered trademarks, service marks, or registered service marks of their respective owners. 24 All statements, specifications, recommendations, and technical information are current or planned as of the publication of this document. They are reliable as of the time of this writing and are presented without warranty of any kind, expressed or implied. In an effort to continuously improve the product and add features, Trapeze Networks reserves the right to change any specifications contained in this document without prior notice of any kind.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2004:05:24 19:18:55-07:00 Create Date : 2002:12:01 12:49:25Z Page Count : 24 Creation Date : 2002:12:01 12:49:25Z Mod Date : 2004:05:24 19:18:55-07:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : Trapeze Networks Technical Publications Metadata Date : 2004:05:24 19:18:55-07:00 Creator : Trapeze Networks Technical Publications Title : Trapeze Regulatory Information Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools