ii© 2006 Trapeze Networks, Inc. All rights reserved. TrademarksTrapeze Networks, the Trapeze Networks logo, Smart Mobile, Mobility Exchange, MX, Mobility Point, MP, Mobility System Software, MSS, RingMaster, Mobility Domain, SentryScan,  ActiveScan, Bonded Auth, FastRoaming, Granular Transmit Power Setting, GTPS, Layer 3 Path Preservation, Location Policy Rule, Mobility Profile, Passport Free Roaming, Time-of-Day Access, TAPA, Trapeze Access Point Access Protocol, Virtual Private Group, VPG, Virtual Service Set, Virtual Site Survey and WebAAA are trademarks of Trapeze Networks, Inc. Trapeze Networks SafetyNet is a service mark of Trapeze Networks, Inc. AirDefense. AirDefense Enterprise, and AirDefense Personal are registered trademarks of AirDefense, Inc. All other products and services are trademarks, registered trademarks, service marks or registered service marks of their respective owners.DisclaimerAll statements, specifications, recommendations, and technical information are current or planned as of the date of the publication of this document. They are reliable as of the time of this writing and are presented without warranty of any kind, expressed or implied. In an effort to continuously improve the product and add features, Trapeze Networks reserves the right to change any specifications contained in this document without prior notice of any kind.Comments and FeedbackYour feedback on Trapeze documentation is important to us. Send any comments and suggestions to doc-bugs@trapezenetworks.com.For the most current version of this document, see www.trapezenetworks.com. Note.  The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.Trapeze Networks, Inc.5753 W. Las Positas Blvd.Pleasanton, CA 94588Tel: +1 925-474-2200Fax: +1 925-251-0642Toll-Free: 877-FLY-TRPZ (877-359-8779)www.trapezenetworks.com
iiiCustomer ServiceFor general information about Trapeze Networks Mobility System™ products and services, visit www.trapezenetworks.com. For warranty, license, and support information, visit the following sites:●Warranty and software licenses. Current Trapeze Networks warranty and software licenses are available at www.trapezenetworks.com/support/warranty.asp.●Support services. For information about Trapeze support services, visit www.trapezenetworks.com/support/. Or call 1-866-877-9822 (in the US or Canada) or +1 925-474-2400 and select option 5. Contacting the Technical Assistance CenterContact the Trapeze Networks Technical Assistance Center (TAC) by telephone, email, or fax. If you have a service contract or are a Trapeze Authorized Partner, log in to www.trapezenetworks.com/support/sup_programs.asp for more help.●Within the US and Canada, call 1-866-TRPZTAC (1-866-877-9822).●Within Europe, call +31 35 64 78 193.●From locations outside the US and Canada, call +1 925-474-2400.●In non-emergencies, send email to support@trapezenetworks.com.●When your case is active, you can fax more information to +1 925-474-2423. Note.  TRAPEZE NETWORKS SELLS AND SERVICES ITS PRODUCTS PRIMARILY THROUGH ITS AUTHORIZED RESELLERS AND DISTRIBUTORS. If you purchased your product from an authorized Trapeze reseller or distributor and do not have a service contract with Trapeze Networks, you must contact your local reseller or distributor for technical assistance.
Trapeze Mobility Point Installation GuideivTAC Response TimeTAC responds to service requests as follows: Information to Have AvailableTo expedite your service request, have the following information available when you call or write to TAC for technical assistance:●Your company name and address●Your name, telephone number, cell phone or pager number, and email address●Name, model, and serial number of the product(s) requiring service●Software version and release number●Output of the show tech-support command●Wireless client information●License levels for RingMaster™ and Mobility Exchange™ (MX™) products●Description of the problem and status of the troubleshooting effortContact method Priority Response timeTelephone Emergency One hourNon-emergency Next business dayEmail Non-emergency Next business day
Contents vContentsCustomer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  iii1  Introducing the Trapeze Networks Mobility System . . . . . . . . . . . . . . . . 1Trapeze Networks Mobility System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Documentation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Safety and Advisory Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Text and Syntax Conventions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  MP Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7External Hardware Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Cable Ports  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9External Antenna Connectors   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Kensington Security Slot  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12MP Mounting Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Status LEDs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Connection Options   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143  Installing and Connecting an MP-422  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Unpacking an MP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Installation Requirements and Recommendations  . . . . . . . . . . . . . . . . . . . . 18RingMaster Network Plan and Work Orders . . . . . . . . . . . . . . . . . . . . . 18MX Switch Recommendation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Wall Installation Recommendations   . . . . . . . . . . . . . . . . . . . . . . . . . . . 19MP Radio Safety Advisories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Radio Frequency Exposure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Additional Radio Safety Advisories  . . . . . . . . . . . . . . . . . . . . . . . . 19Cable Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Installing an MP-422   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Installation Hardware and Tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Suspended Ceiling Installation—Flush Ceiling Tiles  . . . . . . . . . . . . . . 24Suspended Ceiling Installation—Drop Ceiling Tiles . . . . . . . . . . . . . . . 30
Trapeze Mobility Point Installation GuideviJunction Box Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Solid Wall or Ceiling Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Tabletop Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Connecting an MP to an External Antenna  . . . . . . . . . . . . . . . . . . . . . . 49Connecting an MP to an MX Switch  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Verifying MP Health   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51A  MP Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53B  MP Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Introducing the Trapeze Networks Mobility System11Introducing the Trapeze Networks Mobility SystemThis guide shows you how to install a Trapeze Networks™ Mobility Point™ (MP™) access point in a Trapeze Networks Mobility System™ wireless LAN (WLAN).Read this guide if you are a network administrator or other person installing MP access points in a network.Trapeze Networks Mobility SystemThe Trapeze Networks Mobility System is an enterprise-class WLAN solution that seamlessly integrates with an existing wired enterprise network. The Trapeze system provides secure connectivity to both wireless and wired users in large environments such as office buildings, hospitals, and university campuses. The Trapeze Mobility System fulfills the three fundamental requirements of an enterprise WLAN: It eliminates the distinction between wired and wireless networks, allows users to work safely from anywhere (secure mobility), and provides a comprehensive suite of intuitive tools for planning and managing the network before and after deployment, greatly easing the operational burden on IT resources.Trapeze Networks Mobility System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1Documentation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
DocumentationChapter 1Trapeze Mobility Point Installation Guide2The Trapeze Networks Mobility System consists of the following components:●RingMaster tool suite—A full-featured graphical user interface (GUI) application used to plan, configure, deploy, and manage a WLAN and its users●One or more Mobility Exchange™ (MX™) switches—Distributed, intelligent machines for managing user connectivity, connecting and powering Mobility Point (MP) access points, and connecting the WLAN to the wired network backbone●Multiple Mobility Point™ (MP™) access points—Wireless access points (APs) that transmit and receive radio frequency (RF) signals to and from wireless users and connect them to an MX switch●Mobility System Software™ (MSS™)—The operating system that runs all MX switches and MP access points in a WLAN, and is accessible through a command-line interface (CLI), the Web View interface, or the RingMaster GUIDocumentationConsult the following documents to plan, install, configure, and manage a Trapeze Networks Mobility System.Planning, Configuration, and DeploymentTrapeze RingMaster User’s Guide. Instructions for planning, configuring, deploying, and managing the entire WLAN with the RingMaster tool suite. Read this guide to learn how to plan wireless services, how to configure and deploy Trapeze equipment to provide those services, and how to optimize and manage your WLAN.Trapeze RingMaster Reference Manual. Detailed instructions and information for all RingMaster planning, configuration, and management features.
DocumentationChapter 1Introducing the Trapeze Networks Mobility System3Installation●Trapeze Mobility Exchange Hardware Installation Guide. Instructions and specifications for installing an MX switch●Trapeze Mobility System Software Quick Start Guide. Instructions for performing basic setup of secure (802.1X) and guest (Web AAA) access, for configuring a Mobility Domain for roaming, and for accessing a sample network plan in RingMaster for advanced configuration and management●Trapeze Mobility Point MP-422 Installation Guide (this document). Instructions and specifications for installing an MP access point and connecting it to an MX switch●Trapeze Mobility Point MP-620 Installation Guide. Instructions and specifications for installing the MP-620 access point and connecting it to an MX switch●Trapeze Regulatory Information. Important safety instructions and compliance information that you must read before installing Trapeze Networks productsConfiguration and Management●Trapeze RingMaster Reference Manual. Instructions for planning, configuring, deploying, and managing the entire WLAN with the RingMaster tool suite●Trapeze Mobility System Software Configuration Guide. Instructions for configuring and managing the system through the MSS CLI●Trapeze Mobility System Software Command Reference. Functional and alphabetic reference to all MSS commands supported on MX switches and MP access points
DocumentationChapter 1Trapeze Mobility Point Installation Guide4Safety and Advisory NoticesThe following kinds of safety and advisory notices appear in this manual. (For translations of the warning conventions and of all warnings in this manual, see Trapeze Regulatory Information.)     Caution!  This situation or condition can lead to data loss or damage to the product or other property.Warning!  This situation or condition can cause injury. Warning!  High voltage. This situation or condition can cause injury due to electric shock.Warning!  Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment.Note.  This information is of special interest.
DocumentationChapter 1Introducing the Trapeze Networks Mobility System5Text and Syntax ConventionsTrapeze manuals use the following text and syntax conventions:  Convention UseMonospace text Sets off command syntax or sample commands and system responses.Bold text Highlights commands that you enter or items you select.Italic text Designates command variables that you replace with appropriate values, or highlights publication titles or words requiring special emphasis.Menu Name > Command Indicates a menu item that you select. For example, File > New indicates that you select New from the File menu.[ ] (square brackets) Enclose optional parameters in command syntax.{ } (curly brackets) Enclose mandatory parameters in command syntax.| (vertical bar) Separates mutually exclusive options in command syntax.
DocumentationChapter 1Trapeze Mobility Point Installation Guide6
MP Overview72MP OverviewA Trapeze Networks Mobility Point (MP) access point provides IEEE 802.11 wireless access to the network. MP access points are designed for use with a Trapeze Networks Mobility Exchange (MX) switch. MP access points require hardware installation only. All configuration for an MP access point takes place on the MX switch.This guide describes MP model MP-422. The MP-422 has one 802.11a radio and one 802.11b/g radio. Both radios have internal diversity omnidirectional antennas. In addition, both radios have separate jacks for attachment of optional external sectorized or directional antennas. The antennas must be ordered separately.  External Hardware Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8Connection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14Warning!  Installation must be performed by qualified service personnel only. Read and follow all warning notices and instructions marked on the product or included in the documentation. Before installing the product, read the Trapeze Regulatory Information document. Note.  The MP radios are disabled by default and can be enabled only by a system administrator using the MX switch.
External Hardware FeaturesChapter 2Trapeze Mobility Point Installation Guide8External Hardware FeaturesFigure 1 and Figure 2 show the external hardware features of the MP-422.Figure 1. MP Access Point Model MP-422—Top ViewFigure 2. MP Access Point Model MP-422—Bottom View840-9502-0040Diameter16.76 cm (6.6 inches)Height6.10 cm (2.4 inches)External antennaconnectors840-9502-0007UnlockRJ-45 ports Port 2 Port 1Kensington securityslot802.11b/g802.11a
External Hardware FeaturesChapter 2MP Overview9Cable PortsThe MP-422 has two RJ-45 ports. (See Figure 2.) Each port provides a 10/100BASE-TX Ethernet connection to an MX switch. The connection can be direct to an MX-switch or indirect through an intermediate Layer 2 or Layer 3 network. The MP receives power and data through the RJ-45 ports. Use a Category 5 (Cat 5) cable with straight-through signaling and standard RJ-45 connectors to connect an MP to an MX switch or other device in the network. The MP-422 supports 802.3af, and also can receive PoE from Trapeze switches and Trapeze-approved power injectors. (See the Release Notes for Trapeze Networks Mobility Point Access Points.)The two RJ-45 ports support dual-homed configurations for redundancy. An MP uses only one link for booting, configuration, and data transfer. If the link becomes unavailable, the MP can reboot using the other link. The ports are identical except for logical numbering (1 or 2). You can use either port to connect an MP access point to an MX switch. However, an MP always attempts to boot on MP port 1 first. Only if the boot attempt on port 1 fails does the MP attempt to boot on port 2. If one port becomes unavailable, the other port can provide full power to the MP. Note.  MP access points do not support daisy-chain configurations. Do not connect the MP access point to another MP access point.
External Hardware FeaturesChapter 2Trapeze Mobility Point Installation Guide10External Antenna ConnectorsThe MP-422 has connectors for attaching optional external antennas. (See Figure 2.) Table 1 lists the external antenna models.  Figure 3 shows some of the 802.11b/g antennas. Table 1. Trapeze External Antenna ModelsModel Type GainBeamwidthHorizontal VerticalANT-7360 802.11a 8 dBi 360° 15°802.11b/g 6 dBi 360° 25°ANT-7360-OUT 802.11a 8 dBi 360° 15°802.11b/g 6 dBi 360° 22°ANT-5060(ASTN6S)11. The numbers in parentheses are the numbers that appear on the back of an 802.11a antenna’s reflector plate. To verify an 802.11a external antenna’s model number, look for the number in parentheses. 802.11a 14.5 dBi 60° 14°ANT-5120(ASTN6T)802.11a 12.5 dBi 120° 14°ANT-5180(ASTN6H)802.11a 10.8 dBi 180° 14°ANT-1060 802.11b/g 10 dBi 60° 65° ANT-1120 802.11b/g 7 dBi 120° 60°ANT-1180 802.11b/g 6 dBi 180° 40°Note.  The MP-422 radios are certified for use only with these external antennas. This equipment will be marketed and installed by specific contract retailer.  The installation of thisequipment is only be performed by well-trained and qualified personnel.
External Hardware FeaturesChapter 2MP Overview11Figure 3. External 802.11b/g AntennasThe 802.11a external antennas look similar to the 802.11b/g model ANT-1180, but each has a reflector plate specific to the model number. You can identify an 802.11a external antenna’s model by looking on the back of its reflector plate. Do not reverse or remove the reflector plate. It is required for antenna operation. Each antenna comes with a connector cable, mounting hardware, and installation instructions.  Caution!  The external connectors on the MP are labeled: 11B/G and 11A. Each connector is a standard SMA connector. Make sure you attach the antenna to the correct connector.Note.  Operation in the band 5.15–5.25 Ghz is restricted to indoor use only.Model ANT-1060Model ANT-1180Model ANT-1120840-9502-0077
External Hardware FeaturesChapter 2Trapeze Mobility Point Installation Guide12Kensington Security SlotModels MP-422 has a slot for attachment of a Kensington security cable. The cable is not included with the MP but can be ordered separately.MP Mounting OptionsYou can mount an MP access point on any of the following types of surfaces: ●Suspended T-bar ceiling●Junction box●Solid surface wall or ceiling●TabletopStatus LEDsThe MP has LEDs that provide status information for the device. Figure 4 shows the locations of the LEDs. Table 2 describes the LEDs. Figure 4. Health and Radio LEDs—MP-422Note.  The solid surface mounting option requires Cat 5 cable that does not have strain relief.  The other mounting options can use Cat 5 cable with or without strain relief.Radio 2 LEDHealth LEDRadio 1 LED840-9502-0010
External Hardware FeaturesChapter 2MP Overview13Table 2. MP Access Point LEDs—MP-422LED Appearance MeaningHealth Solid green All the following are true:• Management link with an MX switch is operational.• MP access point has booted.• MP access point has received a valid configuration from an MX switch.• At least one radio is enabled or is in sentry mode.Solid amber MP access point is waiting to receive boot instructions and a configuration file from an MX switch. Alternating green and amberMP access point is booting and receiving its configuration file from an MX switch. After the MP boots and receives its configuration, this LED appearance persists until a radio is enabled or is placed in sentry mode.Radio 1Radio 2Solid green A client is associated with the radio.Blinking green Associated client is sending or receiving traffic.Blinking amber Non-associated client is sending or receiving traffic.Alternating green and amberRadio is unable to transmit. This state can occur due to any of the following:• Excessive radio interference in the environment is preventing the radio from sending beacons.• DFS has detected radar and is holding down traffic.• The radio has failed.Unlit Means one of the following:• Radio is disabled and active scan is enabled. (The radio is in sentry mode.)• Radio is enabled, but no clients are associated with it.
Connection OptionsChapter 2Trapeze Mobility Point Installation Guide14Connection OptionsYou can connect an MP access port directly to an MX switch port or indirectly to MX switches through an intermediate Layer 2 or Layer 3 network. In either case, use Category 5 (CAT 5) cable with straight-through signaling for each MP connection.You also can provide data link redundancy by connecting both of its ports directly to MX switch ports or indirectly to MX switches through the network.You can provide MX management redundancy even on a single MP Ethernet port by connecting the MP indirectly to multiple MX switches through an intermediate Layer 2 or Layer 3 network. Note.  Install the Cat 5 cables for the MP access point at the installation site before installing the access point itself. During installation, you will insert the Cat 5 cable(s) into the MP port(s) before attaching the access point to the bracket.
Installing and Connecting an MP-422153Installing and Connecting an MP-422Unpacking an MP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16Installation Requirements and Recommendations  . . . . . . . . . . . . . . . . . . . . .  18Installing an MP-422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22Connecting an MP to an MX Switch   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  50Verifying MP Health  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  51Note.  Before installing an MP access point, you might need to generate a network plan and an MP work order with RingMaster. (See “RingMaster Network Plan and Work Orders” on page 18.)
Unpacking an MPChapter 3Trapeze Mobility Point Installation Guide16Unpacking an MPThe shipping carton for an MP access point contains the following items: ●One MP access point●Mounting kit:●One universal mounting bracket (attached to the MP) ●One paper mounting template (used for marking cutting areas and screw holes) ●One two-piece 14.2-mm (9/16-inch) T-bar clamp ●One two-piece 15.9-mm (5/8-inch) T-bar clamp●One two-piece 23.9-mm (15/16-inch) T-bar clamp●Two #6 sheet metal screws and two drywall anchors●Three adhesive rubber feet●One documentation pack that includes quick mounting instructions and a registration card (not shown)
Unpacking an MPChapter 3Installing and Connecting an MP-42217Figure 5 shows the contents of the shipping carton for model MP-422.Figure 5. MP-422 Shipping Carton ContentsBefore you begin installation:1Open the carton and carefully remove the contents, if you have not already done so.2Place the packing materials back in the carton and save the carton.3Verify that you received each item in the previous list. If any item is missing or damaged, contact Trapeze Networks. T-bar clampsMounting templateRubber feet Universalmounting bracketMounting hardwareMobility point840-9502-0001
Installation Requirements and RecommendationsChapter 3Trapeze Mobility Point Installation Guide18Installation Requirements and RecommendationsFor best results, follow these requirements and recommendations before installing an MP access point.RingMaster Network Plan and Work OrdersIf you are using RingMaster to plan your Trapeze Networks Mobility System installation, you might want to create and verify a network plan for the entire Trapeze network installation and generate an MP work order, before installing MP access points. A network plan and the MP work orders generated from it provide the following information about MP access point installation and configuration:●Number of MP access points required for adequate WLAN capacity in each coverage area●Detailed installation location for each MP access point●Settings for all MP access points in the WLAN(For information about installing RingMaster, creating and verifying a network plan, and generating an MP work order, see the Trapeze RingMaster User’s Guide and Trapeze RingMaster Reference Manual.)MX Switch RecommendationTrapeze Networks recommends that you install and configure the MX switch before installing an MP access point. If the switch is already installed and configured for the MP access point(s), you can immediately verify the cable connection(s) when you plug the cable(s) into the MP access point.Caution!  MP model MP-422 is designed to receive power only from an 802.3af-compliant source, a Trapeze Networks Mobility Exchange (MX) switch, or a Trapeze-approved power injector. Connecting an MP access point to a Power over Ethernet (PoE) device that is not approved by Trapeze Networks can damage the equipment.
Installation Requirements and RecommendationsChapter 3Installing and Connecting an MP-42219(For information about connecting an MP access point to an MX switch port, see “Connecting an MP to an MX Switch” on page 50.)Wall Installation RecommendationsIf you plan to install an MP on a partial wall or other vertical surface, orient the top of the access point (the side with the LEDs) toward the intended coverage area. The radio antennas transmit through the top of the access point but not through the bottom (where the bracket is). This recommendation does not apply if you plan to use external antennas. You can orient the antennas independently of the MP itself. Orient an external antenna to face the intended coverage area. MP Radio Safety AdvisoriesWhen you enable the MP radio(s) as part of MX switch configuration, the radios are able to receive and transmit radio frequency energy as soon as you connect the MP access point(s) to the MX switch, either directly or through the network. Radio Frequency ExposureFederal Communications Commission (FCC) Docket 96-8 for Spread Spectrum Transmitters specifies a safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC-certified equipment. When used with the proper antennas (shipped in the product), Trapeze Networks MP access point products meet the uncontrolled environmental limits found in OET-65 and ANSI C95.1-1991. Proper installation of the MP access point according to the instructions in this manual will result in user exposure that is below the FCC recommended limits.Additional Radio Safety Advisories(For translations of warnings, see Trapeze Regulatory Information.)     Warning!  In the U.S., locate the MP access point and any externally attached antennas a minimum of 20 cm (7.9 inches) away from people. This safety warning conforms with FCC radio frequency exposure limits for dipole antennas such as those used in the MP access point.
Installation Requirements and RecommendationsChapter 3Trapeze Mobility Point Installation Guide20Cable Requirements  Warning!  Do not operate the MP access point near unshielded blasting caps or in an otherwise explosive environment unless the device has been modified for such use by qualified personnel. Warning!  Do not touch or move the MP access point when the antennas are transmitting or receiving.Warning!  Do not hold any radio device so that the antenna is very close to or touching the face, eyes, or other exposed body part while the device's radio antenna is transmitting.Warning!  Before using a wireless device in a hazardous location, consult the local codes, national codes, and safety directors of the location for usage constraints.Warning!  Do not connect or disconnect cables or otherwise work with the MP access point hardware during periods of lightning activity. Note.  The MP access point is intended for indoor use only. Do not install the device outdoors, unless you install it in a properly installed Trapeze Networks outdoor MP enclosure. Note.  To reduce the possibility of connection interference caused by dust, clean the Cat 5 connector pins before inserting a cable into an MP access point.
Installation Requirements and RecommendationsChapter 3Installing and Connecting an MP-42221Cat 5 cable with straight-through signaling must be installed at the site before you install an MP access point. A single connection requires one cable. A dual-homed connection requires two cables.Table 3 lists the pin signals for 10/100 Ethernet straight-through wiring. Pins 4, 5, 7, and 8 are used when Trapeze Power over Ethernet (PoE) is enabled on the port. RD means Receive Data and TD means Transmit Data.Mounting an MP access point on a solid surface requires Cat 5 cable that does not have strain relief. For installation on all other surfaces, you can use Cat 5 cable with or without strain relief.(For more information about cables, see “Cable Ports” on page 9.)Table 3. 10/100 Ethernet Straight-Through Pin SignalsMX Switch Other DevicePin Function Pin Function1RD+1TD+2RD-2TD-3TD+3RD+4 PoE+ 4 PoE+5 PoE+ 5 PoE+6TD-6RD-7 PoE- 7 PoE-8 PoE- 8 PoE-
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide22Installing an MP-422To install an MP-422, use one of the procedures in this section.Installation Hardware and ToolsTable 4 lists the mounting hardware and tools required for each type of installation.Table 4. Required Mounting Hardware and Tools—Model MP-422Mounting Option Required Hardware and Tools Included with the ProductSuspended ceiling—flush ceiling tilesMounting template YesUniversal mounting bracket YesT-bar clampNote: A T-bar clamp is not required for a 23.9-mm (15/16-inch) T-bar ceiling with flush ceiling tiles.YesBox cutter NoSmall screwdriver (3-mm or 1/8-inch)NoSuspended ceiling—drop ceiling tilesMounting template YesUniversal mounting bracket YesT-bar clamp YesBox cutter NoSmall screwdriver (3-mm or 1/8-inch)No
Installing an MP-422Chapter 3Installing and Connecting an MP-42223Figure 6 shows the universal mounting bracket.Junction box Junction box NoTwo #6-32 x 1-inch machine screws YesUniversal mounting bracket YesSmall screwdriver (3-mm or 1/8-inch)No#2 Phillips-head screwdriver NoSolid wall or ceiling Two #6 sheet metal screws and two drywall anchorsYesUniversal mounting bracket YesHammer NoSmall screwdriver (3-mm or 1/8-inch)No#2 Phillips-head screwdriver NoTabletop Universal mounting bracket YesThree adhesive rubber feet YesSmall screwdriver (3-mm or 1/8-inch)NoNote.  The MP-422 model is UL2043 plenum rated, so it also can be installed in the space above the ceiling if preferred.Table 4. Required Mounting Hardware and Tools—Model MP-422 (continued)Mounting Option Required Hardware and Tools Included with the Product
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide24Figure 6. Universal Mounting BracketSuspended Ceiling Installation—Flush Ceiling Tiles(For required mounting hardware and tools, see Table 4 on page 22.)1Select an installation location that is centered over a T-bar in the ceiling.2Cut a hole as follows in the ceiling tile for the Cat 5 cable(s):aPlace the mounting template over the area where you plan to install the MP access point.bUse the box cutter to cut along the line marking the opening for the port connectors.cRemove the mounting template and the material you cut from the ceiling panel.3Determine whether to install a T-bar clamp onto the ceiling T-bar:●If the T-bar width is 14.2 mm (9/16 inches), you need to install the 14.2-mm (9/16-inch) T-bar clamp. Go to step 4.●If the T-bar width is 23.9 mm (15/16 inches), the universal mounting bracket fits directly onto the T-bar. Go to step 5.   840-9502-0018Port connectoropeningT-bar flangesScrew holes
Installing an MP-422Chapter 3Installing and Connecting an MP-422254Install the 14.2-mm (9/16-inch) T-bar clamp onto the ceiling T-bar as shown in Figure 7. aSlide each half of the clamp onto the T-bar so that the clamp lip is fully on the T-bar. bSlide the two halves of the clamp toward each other until the tabs are inserted completely into the holes and the clamp fits snugly on the T-bar.Figure 7. Step 4—Installing a T-bar Clamp5Unlock the universal mounting bracket from the MP access point by inserting the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point as shown in Figure 8.Caution!  To avoid damage to the MP access point’s lock mechanism or electronic components, do not use excessive force when inserting a tool into the Unlock or Lock hole. T-barT-bar clamp halvesSlide together840-9502-0003
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide26Figure 8. Step 5—Unlocking the Bracket6Remove the bracket as shown in Figure 9.Figure 9. Step 6—Removing the Bracket7Install the universal mounting bracket as follows onto the T-bar or T-bar clamp:  aAs shown in Figure 10, place the universal mounting bracket against the T-bar or clamp so that the two screw holes face downward and the two T-bar flanges face upward and are adjacent to the T-bar edges. 840-9502-0011840-9502-0008
Installing an MP-422Chapter 3Installing and Connecting an MP-42227Figure 10. Step 7—Top ViewbProperly align the bracket for mounting by placing the bracket so that its port connector opening is to the left of the hole you cut for the cables.  cRotate the universal mounting bracket clockwise until the flanges snap into place on the T-bar or clamp as shown in Figure 11.Figure 11. Step 7—Bottom View8Pull the Cat 5 cable(s) about 15 cm (about 6 inches) out of the hole in the ceiling tile and through the port connector opening to create enough slack to insert the cable(s). T-bar(Viewed from above ceiling tiles, looking down.)840-9502-0005Universal mountingbracketPort connectoropeningT-barUniversal mounting bracket840-9502-0004Port connectoropening
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide289Insert the Cat 5 cable(s) into the connector(s):●For a single connection, use the connector for port 1.●For redundancy, insert one cable into each connector. 10 Install the Kensington lock, if you plan to use one.aLoop the Kensington lock’s cable around an object that cannot be moved or damaged by a person pulling on the cable.bInsert the key into the Kensington lock.cInsert the Kensington lock into the security slot on the MP.dRotate the key right or left to secure the lock to the MP. ePull on the lock to verify that it is secured to the MP.fRemove the key.11 Lift the MP access point into place on the universal mounting bracket as shown in Figure 12. Make sure the cable feeds properly into the ceiling as you lift the device, and does not become trapped between the access point and the bracket.Figure 12. Step 10—Placing the MP Access Point on the Bracket840-9502-0002
Installing an MP-422Chapter 3Installing and Connecting an MP-4222912 Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch screwdriver into the Lock hole on the access point as shown in Figure 13.Figure 13. Step 11—Locking the Bracket13 To ensure that the MP access point is fully locked onto the bracket, gently pull down on the access point and attempt to rotate it from side to side.14 If the access point comes off the bracket, relock the device onto the bracket as described in step 12 on page 29.15 If the MP requires an external antenna, install and connect the antenna. (See “Connecting an MP to an External Antenna” on page 49.)16 If the other ends of the Cat 5 cable(s) are not already connected and the link activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise, go to “Verifying MP Health” on page 51.Caution!  To prevent possible damage to the MP access point, make sure the device is fully locked onto the bracket before letting go of it.840-9502-0006LockT-bar
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide30Suspended Ceiling Installation—Drop Ceiling Tiles(For required mounting hardware and tools, see Table 4 on page 22.)1Select an installation location that is centered over a T-bar in the ceiling.2Cut a hole as follows in the ceiling tile for the Cat 5 cable(s):aPlace the mounting template over the area where you plan to install the MP access point.bUse the box cutter to cut along the line marking the opening for the port connectors.cRemove the mounting template and the material you cut from the ceiling panel.3Install the T-bar clamp that fits the T-bar: aSlide each half of the clamp onto the T-bar so that the clamp lip is fully on the T-bar. bSlide the two halves of the clamp toward each other until the tabs are inserted completely into the holes and the clamp fits snugly on the T-bar.Figure 14 shows an example for a 23.9-mm (15/16-inch) T-bar. Figure 15 shows an example for a 15.9-mm (5/8-inch) T-bar.Figure 14. Step 3—Installing the T-bar Clamp for a 23.9-mm (15/16-inch) T-barT-barT-bar clamp halvesSlide together840-9502-0003
Installing an MP-422Chapter 3Installing and Connecting an MP-42231Figure 15. Step 3—Installing the T-bar Clamp for a 15.9-mm (5/8-inch) T-bar4Unlock the universal mounting bracket from the MP access point by inserting the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point as shown in Figure 16. Figure 16. Step 4—Unlocking the BracketCaution!  To avoid damage to the MP access point’s lock mechanism or electronic components, do not use excessive force when inserting a tool into the Unlock or Lock hole. T-barT-bar clamp halvesSlide together840-9502-0066840-9502-0011
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide325Remove the bracket as shown in Figure 17.Figure 17. Step 5—Removing the Bracket6Install the universal mounting bracket as follows onto the T-bar clamp:  aAs shown in Figure 18, place the universal mounting bracket against the T-bar clamp so that the two screw holes face downward and the two T-bar flanges face upward and are adjacent to the T-bar edges. bProperly align the bracket for mounting by placing the bracket so that its port connector opening is to the left of the hole you cut for the cables.  cRotate the universal mounting bracket clockwise until the flanges snap into place on the T-bar clamp as shown in Figure 19.840-9502-0008
Installing an MP-422Chapter 3Installing and Connecting an MP-42233Figure 18. Step 6—Top ViewFigure 19. Step 6—Bottom View7Pull the Cat 5 cable(s) about 15 cm (about 6 inches) out of the hole in the ceiling tile and through the port connector opening to create enough slack to insert the cable(s). 8Insert the Cat 5 cable(s) into the connector(s):●For a single connection, use the connector for port 1.●For redundancy, insert one cable into each connector. T- barT-bar clamps(attachedto T-bar)Universal mountingbracket840-9502-0012(Viewed from above ceiling tiles, looking down.)Port connectoropeningT-barUniversal mounting bracket840-9502-0004Port connectoropening
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide349Install the Kensington lock, if you plan to use one.aLoop the Kensington lock’s cable around an object that cannot be moved or damaged by a person pulling on the cable.bInsert the key into the Kensington lock.cInsert the Kensington lock into the security slot on the MP.dRotate the key right or left to secure the lock to the MP. ePull on the lock to verify that it is secured to the MP.fRemove the key.10 Lift the MP access point into place on the universal mounting bracket as shown in Figure 20. Make sure the cable feeds properly into the ceiling as you lift the device, and does not become trapped between the access point and the bracket.Figure 20. Step 9—Placing the MP Access Point on the Bracket11 Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch screwdriver into the Lock hole on the access point as shown in Figure 21. Caution!  To prevent possible damage to the MP access point, make sure the device is fully locked onto the bracket before letting go of it.840-9502-0002
Installing an MP-422Chapter 3Installing and Connecting an MP-42235Figure 21. Step 10—Locking the Bracket12 To ensure that the MP access point is fully locked onto the bracket, gently pull down on the access point and attempt to rotate it from side to side.If the access point comes off the bracket, relock the device onto the bracket as described in step 11 on page 34.13 If the MP requires an external antenna, install and connect the antenna. (See “Connecting an MP to an External Antenna” on page 49.)14 If the other ends of the Cat 5 cable(s) are not already connected and the link activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise, go to “Verifying MP Health” on page 51.840-9502-0006LockT-bar
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide36Junction Box Installation(For required mounting hardware and tools, see Table 4 on page 22.)1Unlock the universal mounting bracket from the MP access point by inserting the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point as shown in Figure 22.Figure 22. Step 1—Unlocking the Bracket2Remove the bracket as shown in Figure 23.Caution!  To avoid damage to the MP access point’s lock mechanism or electronic components, do not use excessive force when inserting a tool into the Unlock or Lock hole. 840-9502-0011
Installing an MP-422Chapter 3Installing and Connecting an MP-42237Figure 23. Step 2—Removing the Bracket3Attach the universal mounting bracket to the junction box as shown in Figure 24:aPlace the universal mounting bracket against the junction box so that the two screw holes face the junction box and align over the screw holes in the box.bInsert the #6-32 x 1-inch machine screws in the universal mounting bracket’s screw holes, and use a #2 Phillips-head screwdriver to tighten them.  840-9502-0008
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide38Figure 24. Step 3—Placing the Bracket on the Junction Box4Pull the Cat 5 cable(s) about 15 cm (about 6 inches) out of the junction box and through the port connector opening to create enough slack to insert the cable(s) into the port connectors. 5Insert the Cat 5 cable(s) into the connector(s): ●For a single connection, use the connector for port 1.●For redundancy, insert one cable into each connector. 6Install the Kensington lock, if you plan to use one.aLoop the Kensington lock’s cable around an object that cannot be moved or damaged by a person pulling on the cable.bInsert the key into the Kensington lock.cInsert the Kensington lock into the security slot on the MP.dRotate the key right or left to secure the lock to the MP. ePull on the lock to verify that it is secured to the MP.fRemove the key.840-9502-0017Junction boxPort connectoropening
Installing an MP-422Chapter 3Installing and Connecting an MP-422397Lift the MP access point into place on the universal mounting bracket. Make sure the cable feeds properly into the junction box as you lift the device, and does not become trapped between the access point and the bracket.8Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch screwdriver into the Lock hole on the access point as shown in Figure 25. Figure 25. Step 7—Locking the Bracket9To ensure that the MP access point is fully locked onto the bracket, gently pull down on the access point and attempt to rotate it from side to side.If the access point comes off the bracket, relock the device onto the bracket as described in step 8 on page 39.10 If the MP requires an external antenna, install and connect the antenna. (See “Connecting an MP to an External Antenna” on page 49.)11 If the other ends of the Cat 5 cable(s) are not already connected and the link activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise, go to “Verifying MP Health” on page 51.Caution!  To prevent possible damage to the MP access point, make sure the device is fully locked onto the bracket before letting go of it.840-9502-0062Lock
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide40Solid Wall or Ceiling Installation(For required mounting hardware and tools, see Table 4 on page 22.)1Prepare holes in the wall or ceiling for the universal mounting bracket, using the following steps:  aPlace the paper mounting template over the location where you want to install the MP access point.bMark the screw hole location(s).❍If you plan to route the Cat 5 cable externally along the wall or ceiling, mark the locations of both the center screw hole and the screw hole by the port connector opening. ❍If you plan to route the Cat 5 cable through a hole in the wall or ceiling, mark the location of the center screw hole only. You cannot use the screw hole by the port connector opening if you cut a hole for the opening. cRemove the template.2Install the drywall anchor(s):aHammer a drywall anchor into each hole, up to the beginning of the threads on the anchor.bScrew each anchor the rest of the way into its hole using a #2 Phillips-head screwdriver.cRemove the screw from each anchor and save the screw(s) for step 6 on page 42.Note.  The solid surface mounting option requires Cat 5 cable that does not have strain relief, unless you plan to route the cable through a hole in the wall or ceiling. The other options can use Cat 5 cable with or without strain relief.Note.  Do not mark the four holes on the edges of the bracket. (These are the holes indicated by the dashed lines in Figure 28.) The MP access point fits into these holes. They are not screw holes.
Installing an MP-422Chapter 3Installing and Connecting an MP-422413Unlock the universal mounting bracket from the MP access point by inserting the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point as shown in Figure 26.Figure 26. Step 3—Unlocking the Bracket4Remove the bracket as shown in Figure 27.Figure 27. Step 4—Removing the BracketCaution!  To avoid damage to the MP access point’s lock mechanism or electronic components, do not use excessive force when inserting a tool into the Unlock or Lock hole. 840-9502-0011840-9502-0008
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide425As shown in Figure 28, feed the Cat 5 cable(s) through the port connector opening and align the universal mounting bracket over the drywall anchors so that the two screw holes in the bracket face the drywall anchors.6Insert the #6 sheet metal screws into the screw holes, and tighten them to secure the universal mounting bracket to the wall or ceiling. (If you routed the Cat 5 cable through a hole in the wall or ceiling, insert the screw into the center screw hole only.) Figure 28. Steps 5 and 6—Bracket Placement on Solid Wall or CeilingNote.  Do not insert screws in the four holes on the edges of the bracket. (These are the holes indicated by the dashed lines in Figure 28.) The MP access point fits into these holes. They are not screw holes.840-9502-0015
Installing an MP-422Chapter 3Installing and Connecting an MP-422437Insert the Cat 5 cable(s) into the connector(s):●For a single connection, use the connector for port 1.●For redundancy, insert one cable into each connector. 8Install the Kensington lock, if you plan to use one.aLoop the Kensington lock’s cable around an object that cannot be moved or damaged by a person pulling on the cable.bInsert the key into the Kensington lock.cInsert the Kensington lock into the security slot on the MP.dRotate the key right or left to secure the lock to the MP. ePull on the lock to verify that it is secured to the MP.fRemove the key.9As shown in Figure 29, place the MP access point on the bracket, making sure to remove any slack that occurs in the cable between the bracket and the MP access point.Figure 29. Step 8—Cable Placement840-9502-0016Universal mounting bracketCable
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide4410 Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch screwdriver into the Lock hole on the access point as shown in Figure 30.Figure 30. Step 9—Locking the Bracket11 To ensure that the MP access point is fully locked onto the bracket, gently pull on the access point and attempt to rotate it from side to side.If the access point comes off the bracket, relock the device onto the bracket as described in step 10 on page 44.12 If the MP requires an external antenna, install and connect the antenna. (See “Connecting an MP to an External Antenna” on page 49.)13 If the other ends of the Cat 5 cable(s) are not already connected and the link activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise, go to “Verifying MP Health” on page 51.Caution!  To prevent possible damage to the MP access point, make sure the device is fully locked onto the bracket before letting go of it.840-9502-0062Lock
Installing an MP-422Chapter 3Installing and Connecting an MP-42245Tabletop Installation(For required mounting hardware and tools, see Table 4 on page 22.)1Reverse the universal mounting bracket:  aUnlock the universal mounting bracket from the MP access point by inserting the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point as shown in Figure 31.Figure 31. Step 1a—Unlocking the BracketCaution!  To avoid damage to the MP access point’s lock mechanism or electronic components, do not use excessive force when inserting a tool into the Unlock or Lock hole. 840-9502-0011
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide46bRemove the bracket as shown in Figure 32.Figure 32. Step 1b—Removing the BracketcTurn over the universal mounting bracket, then align the bracket over the cable ports and the four mounting posts as shown in Figure 33.Figure 33. Step 1c—Turning Over the BracketdOnce the bracket is fully seated, lock the bracket onto the MP access point by inserting the 3-mm or 1/8-inch screwdriver into the Lock hole on the access point as shown in Figure 34.840-9502-0008840-9502-0061
Installing an MP-422Chapter 3Installing and Connecting an MP-42247Figure 34. Step 1d—Locking the Bracket2Attach the three rubber adhesive feet onto the universal mounting bracket, in the three location circles, as shown in Figure 35. Figure 35. Step 2—Installing the Rubber Feet3Insert the Cat 5 cable(s) into the connector(s):●For a single connection, use the connector for port 1.●For redundancy, insert one cable into each connector. 840-9502-0062Lock840-9502-0013
Installing an MP-422Chapter 3Trapeze Mobility Point Installation Guide484Install the Kensington lock, if you plan to use one.aLoop the Kensington lock’s cable around an object that cannot be moved or damaged by a person pulling on the cable.bInsert the key into the Kensington lock.cInsert the Kensington lock into the security slot on the MP.dRotate the key right or left to secure the lock to the MP. ePull on the lock to verify that it is secured to the MP.fRemove the key.5Place the MP access point in the desired location on the table.6If the MP requires an external antenna, install and connect the antenna. (See “Connecting an MP to an External Antenna” on page 49.)7If the other ends of the Cat 5 cable(s) are not already connected and the link activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise, go to “Verifying MP Health” on page 51.
Installing an MP-422Chapter 3Installing and Connecting an MP-42249Connecting an MP to an External AntennaEach radio in an MP-422 can use an optional Trapeze external antenna. To mount the antenna, see the instructions that come with the antenna.  To connect a mounted external antenna to an MP-422:1Attach the exterior antenna cable that is shipped with the antenna to the MP external antenna connector.Both connectors are labeled to indicate the radio type. The MP has standard SMA connectors for attachment to the 802.11b/g antenna and to the 802.11a antenna.(For the location of the external antenna connectors, see Figure 2 on page 8.) 2Attach the other end of the antenna cable to the antenna.3If the other ends of the Cat 5 cable(s) are not already connected and the link activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise, go to “Verifying MP Health” on page 51.Caution!  The external antenna must be installed at least 20 cm from the MP access point.Caution!  The external connectors on the MP are labeled: 11B/G and 11A. Each connector is a standard SMA connector. Make sure you attach the antenna to the correct connector.Note.  If the MP is installed in a Trapeze Networks outdoor MP enclosure, attach the antenna cable to the lightning surge arrestor (if installed) or the enclosure’s SMA bulkhead connector.
Connecting an MP to an MX SwitchChapter 3Trapeze Mobility Point Installation Guide50Connecting an MP to an MX SwitchYou can connect an MP access point directly to an MX switch or indirectly to the switch through an intermediate Layer 2 or Layer 3 network. If you are connecting the MP directly to an MX switch, use the following procedure to insert the cable into the MX switch and verify the link. You can use the CLI or RingMaster to configure an MP connection. If you are installing the MP-422 as a Mesh AP in a WLAN Mesh or wireless bridge configuration, you must configure the MP connection before deploying the MP in its final location. (See the Trapeze Mobility System Software Configuration Guide or the Trapeze RingMaster User’s Guide.)Figure 36 shows how to insert a Cat 5 cable into 10/100 Ethernet port on an MX switch. Refer to this figure as you perform the procedure. Figure 36. 10/100 Cat 5 Cable InstallationMobility ExchangeMX-20Ethernet cable (Cat 5 cable)MP, switch, server or other device840-9502-0058Ethernet port
Verifying MP HealthChapter 3Installing and Connecting an MP-422511Insert a Cat 5 cable with a standard RJ-45 connector as shown in Figure 36. For connection to an MP access point, use a straight-through cable.2When the link is activated, observe the MP LED for the port on the MX switch:Verifying MP HealthAfter you install the MP access point and enable PoE on the Ethernet cable connected to the MP, you can easily verify the MP’s status by observing the LEDs, particularly the health LED. (See Figure 4 on page 12.) The health or LINK LED indicates whether the MP access point is ready for operation. MP LED Appearance MeaningSolid green For an MP access point’s active link, all the following are true:• MP access point has booted.• MP access point has received a valid configuration from the MX switch.• Management link with an MP access point is operational.• At least one radio is enabled or is in sentry mode.For an MP access point’s secondary link, the link is present.Alternating green and amberMP access point is booting with an image received from the MX switch. After the access point boots and receives its configuration, this LED appearance persists until a radio is enabled or is placed in sentry mode.Solid amber PoE is on.Blinking amber MP is unresponsive or there is a PoE problem.Unlit PoE is off.
Verifying MP HealthChapter 3Trapeze Mobility Point Installation Guide52●If the LED is green and glowing steadily, the MP has been booted successfully by the MX switch and is ready for operation. ●If the LED is not steadily glowing green, contact the system administrator for the MX switch or, if you are the system administrator, see Appendix A, “MP Troubleshooting,” on page 53.
MP Troubleshooting53AMP TroubleshootingAfter you insert a Cat 5 cable into an MP access point’s port connector and enable PoE on the cable, observe the device’s health or LINK LED to determine the status of the connection with the MX switch. ●If the LED is green and is glowing steadily, the MP has been booted successfully by the MX switch and is ready for operation. ●If the LED is not steadily glowing green, see Table 5.(For descriptions of all the LEDs, see “Status LEDs” on page 12.)Table 5. Health LED StatesHealth or LINK LED Appearance  Diagnosis RemedyNot solid green MP radio needs to be enabled.Enable at least one of the radios. If the LED is still not solid green, try the remedy listed in this table based on the LED’s appearance.Unlit MP access point is not receiving power.Check the Cat 5 cable connection(s).For a direct connection to an MX switch:• Verify that Power over Ethernet (PoE) is enabled on the MX switch port connected to the MP access point.For an indirect connection through the network:• Verify that a Trapeze-approved PoE source is supplying power to the MP.
Appendix ATrapeze Mobility Point Installation Guide54Slowly alternating green and amberMP access point is booting with an image received from an MX switch.Wait a few seconds for the boot process to complete. If this LED appearance persists, enable a radio or place a radio in sentry mode.Solid amber MP access point is waiting to receive boot instructions and a configuration file from an MX switch.Wait a few seconds for the boot process to begin. If the LED remains amber, try the remedies for the other health LED appearances. If the LED still remains amber, make sure the MP access point is securely connected to its PoE source and to the network or MX switch. Table 5. Health LED States (continued)Health or LINK LED Appearance  Diagnosis Remedy
MP Technical Specifications55BMP Technical SpecificationsThis appendix lists the technical specifications for the Trapeze Networks MP-422 access point. Table 6 lists the mechanical and compliance specifications. (For detailed compliance information, see the Trapeze Regulatory Information document.) Table 7, Table 8, and Table 9 list the radio specifications. Table 10 lists the MAC address allocation scheme.(For specifications for the MX switch, see the Trapeze Mobility Exchange Installation and Basic Configuration Guide.)   Note.  This Listed Accessory is designed and approved to be used only with Trapeze Networks Mobility Exchange (MX) models MX-216, MX-20, MX-8, and MXR-2. (The MX-400 and MX-200 switches do not directly connect to the MP.)Note.  The MP radios are disabled by default and can be enabled only by the system administrator using the RingMaster management application or the MX switch’s command-line interface (CLI). Note.  The radio frequency band, operating channels, and transmit power depend on the country of operation specified by the system administrator using RingMaster or the MX switch’s CLI.
Appendix BTrapeze Mobility Point Installation Guide56 Table 6. MP Mechanical and Compliance SpecificationsSpecification DescriptionSize Diameter: 16.76 cm (6.6 inches)Height: 6.1 cm (2.4 inches)Weight Without mounting bracket: 0.45 kg (16 ounces)With mounting bracket: 0.5 kg (17.5 ounces) Operating Temperature 0° C to +50° C (32° F to 122° F)Storage Temperature -20° C to +70° C (-4° F to +158° F)Humidity 10% to 95% noncondensingPower over Ethernet (PoE)42 VDC to 57 VDC (46 VDC nominal)IEEE 802.3af (MP-422, MP-372, MP-341, MP-352, and MP-52)Status indicators Health/MX and radio LEDs(For descriptions of the LEDs, see “Status LEDs” on page 12.) Wired network ports Two RJ-45 ports for 10/100BASE-T Ethernet and Power over Ethernet (PoE)Standards compliance IEEE 802.11IEEE 802.11aIEEE 802.11bIEEE 802.11gIEEE 802.3afSafety and electromagnetic complianceFCC Part 15, UL 60950IC Part 15, CSA 22.2 N0-950, RSS-139-1 and RSS-210ETS 300 328 (2.4 GHz) and 301 893 (5 GHz), EN 301 489-17R&TTE Directive 1999/5/ECTELEC, ARIB T66GBT-15941-1995, GBT-16841-1997LP0002
Appendix BMP Technical Specifications57Encryption Wi-Fi Protected Access (WPA)Advanced Encryption Standard (AES) 40-bit/104-bit Wired-Equivalent Privacy (WEP)General Power-save mode supportedTransmit power control in 1 dBm incrementsSupports up to 250 clients per radioTable 7. 802.11a Radio SpecificationsSpecification DescriptionAntenna type Integrated diversity omnidirectionalExternal sectorized or directional (optional)Antenna gain Internal: 5 dBiExternal: • ANT-5060—14.5 dBi• ANT-5120—12.5 dBi• ANT-5180—10.8 dBi• ANT-7360—8 dBi• ANT-7360-OUT—8 dBiFrequency band 5.15 GHz to 5.85 GHz based on country regulationsOperating channels Based on the country of operation specified by the system administratorAssociation rates 54 Mbps, 48 Mbps, 36 Mbps, 24 Mbps, 18 Mbps, 12 Mbps, 9 Mbps, and 6 Mbps, with automatic fallbackModulation Orthogonal frequency division multiplexing (OFDM)Transmit power Based on the country of operation specified by the system administratorTable 6. MP Mechanical and Compliance Specifications (continued)Specification Description
Appendix BTrapeze Mobility Point Installation Guide58Table 8. 802.11b Radio SpecificationsSpecification DescriptionAntenna type Integrated diversity omnidirectionalExternal sectorized or directional (optional)Antenna gain Internal: 3 dBiExternal: • ANT-1060—greater than 10 dBi• ANT-1120—7 dBi or more • ANT-1180—6 dBi or more• ANT-7360—6 dBi• ANT-7360-OUT—6 dBiFrequency band 2.4 GHz to 2.4835 GHz based on country regulationsOperating channels Based on the country of operation specified by the system administratorAssociation rates 11 Mbps, 5.5 Mbps, 2 Mbps, and 1 Mbps, with automatic fallbackModulation Direct-sequence spread-spectrum (DSSS)Transmit power Based on the country of operation specified by the system administratorTable 9. 802.11g Radio SpecificationsSpecification DescriptionAntenna type Integrated diversity omnidirectionalExternal sectorized or directional (optional)Antenna gain Internal: 3 dBiExternal: • ANT-1060—greater than 10 dBi• ANT-1120—7 dBi or more • ANT-1180—6 dBi or more• ANT-7360—6 dBi• ANT-7360-OUT—6 dBi
Appendix BMP Technical Specifications59MAC AddressesEach MP-422 is assigned a unique block of 64 MAC addresses. Each radio has 32 MAC addresses and can therefore support up to 32 SSIDs, with one MAC address assigned to each SSID as its BSSID.An MP’s MAC address block is listed on a label on the back of the MP. If the MP is already deployed and running on the network, you can display the MAC address assignments by using the show ap status command.All MAC addresses on an MP are assigned based on the MP’s base MAC address, as described in Table 10.Frequency band 2.4 GHz to 2.4835 GHz based on country regulationsOperating channels Based on the country of operation specified by the system administratorAssociation rates 54 Mbps, 48 Mbps, 36 Mbps, 24 Mbps, 18 Mbps, 12 Mbps, 9 Mbps, and 6 Mbps, with automatic fallbackModulation Orthogonal frequency division multiplexing (OFDM)Transmit power Based on the country of operation specified by the system administratorTable 9. 802.11g Radio Specifications (continued)Specification Description
Appendix BTrapeze Mobility Point Installation Guide60Table 10. MAC Address Allocations on MP-422MP base MAC Address• The MP has a base MAC address. All the other addresses are assigned based on this address. Ethernet Port MAC Addresses• Ethernet port 1 equals the MP base MAC address.• Ethernet port 2 equals the MP base MAC address + 1.802.11a Radio and SSID MAC Addresses• The 802.11a radio equals the MP base MAC address + 1.• The BSSIDs for the SSIDs configured on the 802.11a radio end in odd numbers. The first BSSID is equal to the MP’s base MAC address + 1. The next BSSID is equal to the MP’s base MAC address + 3, and so on. 802.11b/g Radio and SSID MAC Addresses• The 802.11b/g radio equals the MP base MAC address. • The BSSIDs for the SSIDs configured on the 802.11b/g radio end in even numbers. The first BSSID is equal to the MP’s base MAC address. The next BSSID is equal to the MP’s base MAC address + 2, and so on.
Index61IndexAaccess point. See MP (Mobility Point)activating an MP  50advisory notices, explanations of  4ANT-1060 10ANT-1120 10ANT-1180 10ANT-5060 10ANT-5120 10ANT-5180 10antennas, external  10Bbracket 12Ccable ports  9cable requirements  20solid surface  40Category 5 cables  9strain relief  40ceiling installationdrop tiles  30solid 40suspended, flush tiles  24connectionsdual-homed 9external antenna  49LEDs 51MX (Mobility Exchange)  50troubleshooting 53conventions, text and syntax  5customer service  iiiDdocumentation conventions  5documentation, product  2drop ceiling installation  30dual-homed connections  9EEthernetcable requirements  20connections to an MX switch, instructions 50connections to an MX switch, MP port locations 9LEDs 51ports 9external antennaconnections to an MP, instructions  49external antennas  10Fflush ceiling installation  24Hhardwarebottom view  8features 8inventory 16mounting bracket  12required, list of  22top view  8health LEDdescription 13
Trapeze Mobility Point Installation Guide62troubleshooting with  53verifying MP health with  51Iinstallationjunction box  36MP 15, 22requirements 18requirements, tools  22solid surface  40suspended ceilings  30suspended ceilings, flush tiles  24tabletop 45T-bar ceilings. See suspended ceilingswarnings, cables  20warnings, radio  19warnings, service  7IP addresses  59Jjunction box installation  36KKensington security slot  12LLEDs 12health 13, 51, 53MP (on MX)  51radio 13linksdual-homed 9LEDs 51MP 51troubleshooting 53MMAC addresses  59manuals, product  2Mobility Exchange. See MXMobility Point. See MPmodel numbersexternal antennas  10mounting bracket  12mounting options  12MP (Mobility Point)description of  7installation 15, 22specifications 55troubleshooting 53MX (Mobility Exchange)connections 14, 50MP LEDs  51recommendation 18Nnetwork plan, RingMaster  18PPoE (Power over Ethernet)dual-homed connections  9pin signals  21specifications 56use with Trapeze devices only  18ports 9product documentation  2Rradio LEDs  13radiosdefault state  7health 53radio LEDs  13specifications 55status 13troubleshooting 53warnings 19redundancy 9requirements 18cables 20hardware 22
Index63RingMasterwall installation recommendations  19work order  18RJ-45s 9Ssafety notices, explanations of  4solid surface installation  40specifications 55status LEDs. See LEDsstatus lights. See LEDssuspended ceilings, installationdrop tiles  30flush tiles  24switch. See MX (Mobility Exchange)syntax conventions  5Ttabletop installation  45TAC (Technical Assistance Center)  iiiT-bar ceilings. See suspended ceilingsTechnical Assistance Center  iiitechnical specifications  55technical support  iiitools 22Trapeze customer service  iiiTrapeze Networks Mobility System  1troubleshooting 53Uuniversal mounting bracket  12unpacking an MP  16Wwall installationjunction box  36recommendations 19solid 40warningscable 20installation 7radio 19work order, RingMaster  18
Trapeze Mobility Point Installation Guide64
      Trapeze Regulatory Information      Hardware Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1 Safety and Advisory Notice Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2 Regulatory Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3 Declarations of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7 Translations of Warnings and Warning Conventions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9   This document contains important safety information. Read all the safety warnings before you begin installation.   Hardware Safety Symbols  Trapeze Networks Mobility System™ products are labeled with one or more of the following safety symbols:     Warning! High voltage.    Attention! Refer to the manual. Warning! Class 1 Laser. Protective ground (earth) terminal.    Frame or chassis terminal.       Trapeze Networks, Inc. 5753 W. Las Positas Blvd. Pleasanton, CA  94588 Tel:  +1 925-474-2200 Fax: +1 925-251-0642 For the most current version of this document see www.trapezenetworks.com Toll-Free: 877-FLY-TRPZ (877-359-8779) Part Number: 730-9502-0037, Revision D
2 Trapeze Regulatory Information   Safety and Advisory Notice Conventions      Direct current (DC).  Alternating current (AC). Complies with Underwriters Laboratories regulations in United States and Canada. Complies with European Union (CE) regulations.  Contains a radio transmitter that complies with the Radio and Telecommunications Technical Equipment (R&TTE) Directive 1995/5/EC to an unharmonized frequency spectrum.    Safety and Advisory Notice Conventions  The following safety and advisory notices can appear in Trapeze Networks product documentation:   Warning!  This situation or condition can cause injury.    Warning!  High voltage. This situation or condition can cause injury due to electric shock.    Warning!  Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment.    Caution!  This situation or condition can lead to data loss or damage to the product or other property.    Note.  This information is of special interest.
Trapeze Regulatory Information 3 Regulatory Compliance Information         Regulatory Compliance Information  Trapeze Networks products cause no electromagnetic interference to other devices if installed and operated properly and without modification.  Modification Prohibition    Caution!  The Part 15 radio device in the access point operates on a noninterference basis with other devices operating at the same frequency. Any modification to this device not expressly approved by Trapeze Networks can void your authority to operate the device.    The manufacturer, Trapeze Networks, is not responsible for any interference caused by unauthorized modification of the devices included with this product, or the substitution or attachment of connecting cables or equipment other than supplied by Trapeze Networks.  The correction of interference caused by such unauthorized modification, substitution, or attachment is your responsibility.  Trapeze Networks and its authorized resellers or distributors are not liable for any damage or violation of government regulations that might arise from failure to comply with these guidelines.  Wiring Notice    Note.  Other than the power cord, the wiring interconnecting these units is designed to be used intra-building only.    Federal Communications Commission Notice (United States)  This device uses, generates, and radiates radio frequency energy. The radio frequency energy produced by this device is well below the maximum exposure allowed by the Federal Communications Commission (FCC).  Operation is subject to the following conditions:  l This device may not cause harmful interference.  l This device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits of a Class B or Class A (as marked) digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment.
4 Trapeze Regulatory Information Regulatory Compliance Information         This accepted equipment is designed and tested to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed in accordance with the instruction manual, may cause harmful interference.  There is no guarantee that interference will not occur. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures:  l Reorient or relocate the device to reorient or relocate the receiving antenna.  lIncrease separation between the equipment and receiver.  Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.    However, there is no guarantee that interference will not occur in a particular installation.    If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:    Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.  If this device is going to be operated in 5.15 ~ 5.25GHz frequency range, then it is restricted in indoor environment only.  IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.   Canadian Department of Communications Industry Canada Notice (Canada)  This digital apparatus meets the requirements of Canadian Interference-Causing Equipment Regulation RSS-210.  Cet appareil respecte les exigences du Reglement sur le material broilleur du Canada.  This device complies with the limits of Industry Canada (IC). Operation is subject to the following
Trapeze Regulatory Information 5 Regulatory Compliance Information     conditions:  l This device may not cause harmful interference.  l This device must accept any interference received, including interference that may cause undesired operation.  The device is certified to the requirements of IC RSS-139-1. The use of this device in a system operating either partially or completely outdoors may require the user to obtain a license for the system. For more information, contact your local Industry Canada office.  The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb  Radio Frequency Compliance Information (European Union)  The MP access point has been tested and found to comply with European Telecommunications Standard (ETS) 300 328 for 2.4-GHz equipment and ETS 301 893 for 5-GHz equipment. These standards cover wideband data transmission systems referred to in European Conference of Postal and Telecommunications Administrations (CEPT) recommendation T/R 10.01.  Voluntary Control Council for Interference by Information Technology Equipment Notice (Japan)
6 Trapeze Regulatory Information Regulatory Compliance Information         Translation: This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.  Regulatory Compliance Notice (Korea)
Trapeze Regulatory Information 7 Regulatory Compliance Information         Lithium Battery Caution  The MX switch contains a lithium battery. If you need to replace the battery, make sure you dispose of the battery properly according to local regulations and replace the battery only with another comparable lithium battery.     Caution!  Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.   Attentie!  Gevaar voor explosie als accu wordt vervangen door onjuist type. Verwijder gebruikte accu's in overeenstemming met de instructies.   Vorsicht!  Wenn die Batterie durch einen falschen Typ ersetzt wird, besteht das Risiko einer Explosion. Entsorgen Sie die gebrauchten Batterien entsprechend den Anweisungen.   Attention !  Risque d'explosion si la batterie est remplacée par une batterie non conforme. Jetez les batteries usagées selon les instructions.   ¡Precaución!  Peligro de explosión si la bateria es reemplazada con otra de tipo incorrecto. Deseche las baterias usadas siguiendo las instrucciones.   Advarsel!  Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type.
8 Trapeze Regulatory Information     Declarations of Conformity     Declarations of Conformity  The following sections contain declarations of conformity.  European Union Notice  All products labeled with the CE marking comply with the Electromagnetic Compliance (EMC) Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community.  Compliance with these directives implies conformity to the following European Norms (ENs).  The equivalent international standards are listed in parentheses.  l EN 55022 (CISPR 22)—Electromagnetic Interference  l EN 55024 (IEC 61000-4-2, -3, -4, -5, -6, -8, -11)—Electromagnetic Immunity  l EN 61000-3-2 (IEC 610000-3-2)—Power Line Harmonics  l EN 61000-3-3 (IEC 610000-3-3)—Power Line Flicker  l EN 60 950 (IEC 60950)—Product Safety  Products labeled with the CE alert marking contain a radio transmitter that complies with the Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC to an unharmonized frequency spectrum, issued by the Commission of the European Community.  Compliance with these directives implies conformity to the following European Norms (ENs).  Where applicable, the equivalent international standards are listed in parentheses.  l EN 60 950 (IEC 60950)—Product Safety  l EN 300 328—Technical Requirements for Radio Equipment  l ETS 300 826 and ETS 301 489-17—General EMC requirements for radio equipment  l ETS 301 893—Broadband Radio Access Networks (BRAN)  l HiperLAN/2  l Harmonized EN covering essential requirements of Article 3.2 of the R&TTE Directive— Point-to-multipoint digital fixed radio systems and antennas  To determine the type of transmitter, check the identification label on your product.
Trapeze Regulatory Information 9     Declarations of Conformity     European Community, Switzerland, Norway, Iceland, and Liechtenstein Declarations  Table 1 lists European declarations of conformity with Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC. Table 1. European Declarations of Conformity with R&TTE Directive 1999/5/EC Language Declaration Statement  English This equipment complies with the essential requirements and other relevant provisions of Directive 1999/5/EC. Deutsch Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie 1999/5/EU. Dansk Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF.  ¢EllhnaV AutoV o exoplismoV summorjwnetai me tiV ousiwdeiV apaithseiV kai tiV loipeV diataxeiV thV OdhgiaV 1999/5/EK. Español Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC.  Français Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC. Íslenska Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB. Italiano Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC.  Nederlands Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC. Norsk Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC. Português Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.  Suomalainen Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen. Svenska Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC.
10 Trapeze Regulatory Information Translations of Warnings and Warning Conventions         Translations of Warnings and Warning Conventions   Warning Conventions   Warning!  This situation or condition can cause injury.   Waarschuwing!  Deze situatie of omstandigheid kan letsel veroorzaken.   Warnung!  Diese Situation oder dieser Zustand kann zu Verletzungen führen.   Avertissement !  Cette situation ou cette condition peuvent provoquer des blessures.   Aviso  Esta situación o condición puede causar lesiones.      Warning!  High voltage. This situation or condition can cause injury due to electric shock.   Waarschuwing!  Hoog voltage. Deze situatie of omstandigheid kan letsel veroorzaken door elektrische schokken.   Warnung!  Hochspannung. Diese Situation oder dieser Zustand kann einen Elektroschock verursachen.   Avertissement !  Haute tension. Cette situation ou cette condition peuvent provoquer des blessures dues à des décharges électriques.   Aviso  Alta tensión. Esta situación o condición puede causar lesiones por descarga eléctrica.
Trapeze Regulatory Information 11Translations of Warnings and Warning Conventions           Warning!  Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment.   Waarschuwing!  Straling. Deze situatie of omstandigheid kan letsel veroorzaken door onjuist gebruik van glasvezelapparatuur.   Warnung!  Strahlung. Diese Situation oder dieser Zustand kann durch falschen Umgang mit glasfaserbasierten Geräten zu Verletzungen führen.   Avertissement !  Radiation. Cette situation ou cette condition peuvent provoquer des blessures dues à une manipulation inappropriée d’appareils équipés de fibres optiques.   Aviso  Radiación. Esta situación o condición puede causar lesiones debido a un manejo inadecuado del equipamiento de fibra óptica.    Qualified Service Personnel Warning   Warning!  Installation must be performed by qualified service personnel only. Read and follow all warning notices and instructions marked on the product or included in the documentation. Before installing the product, read the rest of this document.   Waarschuwing!  De installatie mag alleen worden uitgevoerd door bevoegd onderhoudspersoneel. Het is essentieel dat u kennis neemt van alle waarschuwingen en instructies aangebracht op het product zelf en/of opgenomen in de documentatie. Voordat u het product installeert, dient u dit document in zijn geheel te hebben gelezen.   Warnung!  Die Installation darf nur von einem qualifizierten Kundendienstmitarbeiter vorgenommen werden. Lesen Sie alle Warnhinweise und Anweisungen auf dem Produkt oder in der Dokumentation und befolgen Sie sie. Bevor Sie das Produkt installieren, sollten Sie dieses Dokument vollständig lesen.   Avertissement !  L’installation doit être effectuée uniquement par des techniciens qualifiés. Lisez et suivez toutes les notices d’avertissement et les instructions figurant sur le produit ou comprises dans la documentation. Lisez le reste de ce document avant d’installer ce produit.   Aviso  Sólo puede realizar la instalación personal cualificado de asistencia técnica. Lea y siga todas las notas de advertencia e instrucciones indicadas en el producto o incluidas en la documentación. Antes de instalar el producto, lea el resto de este documento.
12 Trapeze Regulatory Information Translations of Warnings and Warning Conventions         Radio Safety Warnings   Warning!  Do not operate the MP access point near unshielded blasting caps or in an otherwise explosive environment unless the device has been modified for such use by qualified personnel.   Waarschuwing!  Het MP-toegangspunt mag niet worden gebruikt in de nabijheid van onafgeschermde slaghoedjes of in een andere explosieve omgeving tenzij het apparaat voor een dergelijk gebruik is aangepast door bevoegd personeel.   Warnung!  Die MP-Zugriffspunkte sollten nicht neben ungeschirmten Sprengkapseln betrieben oder in einer explosiven Umgebung eingesetzt werden. Für einen solchen Einsatz muss das Gerät von einem qualifizierten Kundendienstmitarbeiter entsprechend angepasst werden.   Avertissement !  Le point d’accès MP ne doit pas fonctionner près de détonateurs non blindés ou dans un autre environnement qui présent un risque d’explosion, à moins que cet appareil n’ait été adapté en vue d’une telle utilisation par du personnel qualifié.   Aviso  No utilice el punto de acceso de MP cerca de detonadores no blindados ni en un entorno explosivo, a menos que haya sido modificado el dispositivo con ese fin por personal cualificado.      Warning!  Do not touch or move the MP access point when the antennas are transmitting or receiving.   Waarschuwing!  Het MP-toegangspunt mag niet worden aangeraakt of verplaatst terwijl de antennes uitzenden of ontvangen.   Warnung!  Berühren oder bewegen Sie den MP-Zugriffspunkt nicht, während die Antennen senden oder empfangen.   Avertissement !  Ne touchez ni ne déplacez le point d’accès MP lorsque les antennes sont en cours de transmission ou de réception.   Aviso  No toque ni mueva el punto de acceso de MP cuando las antenas estén transmitiendo o recibiendo señales.
Trapeze Regulatory Information 13Translations of Warnings and Warning Conventions             Warning!  Do not hold any radio device so that the antenna is very close to or touching the face, eyes, or other exposed body part while the device's radio antenna is transmitting.   Waarschuwing!  De antenne van een apparaat dat radiogolven aan het uitzenden is, mag nooit vlakbij of tegen het gezicht, de ogen of een andere onbedekt deel van het lichaam worden gehouden.   Warnung!  Halten Sie die drahtlosen Geräte während der Übertragung mit der Antenne nicht nahe ans Gesicht, an die Augen oder an andere ungeschützte Körperteile und berühren Sie die Antenne nicht.   Avertissement !  Ne maintenez pas l’antenne d’un appareil radio près du visage, des yeux ou d’une autre partie du corps exposée ou en contact avec ces parties du corps, lorsqu’elle est en cours de transmission.   Aviso  No coloque ningún dispositivo de radio demasiado cerca de la antena ni en contacto con la cara, los ojos u otras partes del cuerpo que estén al descubierto mientras la antena de radio del dispositivo esté transmitiendo señales.      Warning!  Before using a wireless device in a hazardous location, consult the local codes, national codes, and safety directors of the location for usage constraints.   Waarschuwing!  Voordat u een draadloos apparaat gebruikt op een gevaarlijke locatie, dient u de plaatselijke en landelijke voorschriften, en de veiligheidsvoorschriften voor de locatie te raadplegen over eventuele gebruiksbeperkingen.   Warnung!  Bevor Sie drahtlose Geräte an einem gefährlichen Standort einsetzen, sollten Sie die lokalen und nationalen Regelungen und Sicherheitsbestimmungen des Standorts auf Nutzungsbeschränkungen überprüfen.   Avertissement !  Avant d’utiliser un appareil sans fil dans un endroit dangereux, consultez la réglementation locale et nationale ainsi que les responsables de la sécurité de l’endroit concerné pour obtenir des informations relatives aux conditions et aux limites d’utilisation de cet appareil.   Aviso  Antes de utilizar un dispositivo inalámbrico en una ubicación peligrosa, consulte los códigos locales y nacionales y a los responsables de seguridad de la ubicación para conocer las restricciones de uso.
14 Trapeze Regulatory Information Translations of Warnings and Warning Conventions         Lightning Warning   Warning!  Do not connect or disconnect cables or otherwise work with the MP access point hardware during periods of lightning activity.   Waarschuwing!  Tijdens onweer met bliksem mogen kabels nooit worden aangekoppeld aan of losgekoppeld van het MP-toegangspunt of andere werkzaamheden aan het MP-toegangspunt worden verricht.   Warnung!  Verbinden und trennen Sie während eines Gewitters keine Kabel zum MP-Zugriffspunkt und arbeiten Sie nicht damit.   Avertissement !  Ne connectez pas et ne déconnectez pas de câbles et, de manière générale, ne travaillez pas sur le matériel du point d’accès MP lorsqu’il y a un risque de foudre.   Aviso  No conecte ni desconecte cables, ni tampoco trabaje con el hardware del punto de acceso de MP durante una tormenta eléctrica.    Laser Warning   Warning!  The gigabit Ethernet fiber-optic interfaces use Class 1 lasers. To reduce the risk of eye injury, do not stare into the interface or otherwise direct the laser beam into your eye.   Waarschuwing!  De gigabit Ethernet glasvezel interfaces gebruiken Klasse 1 lasers. Teneinde oogletsel te voorkomen, mag u nooit rechtstreeks in de interface kijken of een laserstraal op andere wijze op uw oog richten.   Warnung!  Für die Glasfaserschnittstellen werden bei Gigabit-Ethernet Class 1-Laser verwendet. Vermeiden Sie Augenverletzungen, indem Sie nicht in die Schnittstelle schauen oder den Laserstrahl auf Ihr Auge richten.   Avertissement !  Les interfaces Gigabit Ethernet à fibre optique utilisent des lasers de classe 1. Pour réduire le risque de blessure oculaire, ne regardez pas directement l’interface et ne dirigez pas le faisceau laser vers vos yeux.   Aviso  Las interfaces de fibra óptica Gigabit Ethernet utilizan láseres de Clase 1. Para reducir el riesgo de sufrir lesiones oculares, no mire fijamente la interfaz ni dirija el rayo láser hacia los ojos.
Trapeze Regulatory Information 15Translations of Warnings and Warning Conventions         Earth Ground Warning   Warning!  Earth grounding is required for an MX switch installed in a rack. If you are relying on the rack to provide ground, the rack itself must be grounded with a ground strap to the earth ground.   Metal screws attaching the switch to the rack provide ground attachment to the rack.   Waarschuwing!  Aarding aan de grond is vereist voor een MX switch geïnstalleerd in een rek. Als u het rek gebruikt als massa, dan dient het rek zelf via een aardingsstrip verbonden te zijn met grondaarding.   De metalen bouten waarmee de switch is bevestigd aan het rek zorgen voor aarding van het rek.   Warnung!  Für einen MX-Switch, der in einem Rack installiert ist, ist eine Erdung erforderlich. Wenn Sie die Erdung über das Rack vornehmen möchten, müssen Sie es über ein Masseband mit der Erde verbinden. Die Erdung zum Rack erfolgt dann über die Metallschrauben, die den Schalter mit dem Rack verbinden.   Avertissement !  La mise à la terre est requise pour un commutateur MX installé dans un châssis. Si vous utilisez le châssis comme masse, celui-ci doit être mis à la terre au moyen d’un câble de mise à la terre relié à la prise de terre.   Les vis métalliques qui attachent le commutateur au châssis assurent une mise à la masse au châssis.   Aviso  Un interruptor MX instalado en un bastidor necesita una conexión a masa. Para utilizar el bastidor como conexión a masa debe conectar a masa dicho bastidor con una tira de conexión a masa. Los tornillos metálicos que fijan el interruptor al bastidor proporcionan conexión a masa al bastidor.
16 Trapeze Regulatory Information Translations of Warnings and Warning Conventions         Rack Installation Warnings   Warning!  Trapeze Networks recommends that you ask someone to assist you with the remaining steps. If you accidentally drop the MX switch, you can be injured and the switch can be damaged.   Waarschuwing!  Trapeze Networks adviseert dat u bij het uitvoeren van de resterende stappen iemand ter assistentie vraagt. Als u de MX switch per ongeluk laat vallen, kunt u letsel oplopen en kan de switch beschadigd raken.   Warnung!  Trapeze Networks empfiehlt, dass Sie jemanden bitten, Ihnen beim Ausführen der weiteren Schritte zu helfen. Wenn Sie den MX-Switch versehentlich fallen lassen, könnten Sie dadurch verletzt werden und der Switch wird eventuell beschädigt.   Avertissement !  Trapeze Networks vous conseille de demander l’assistance d’une autre personne pour les étapes restantes. Si vous laissez tomber le commutateur MX par accident, vous pouvez vous blesser et le commutateur risque d’être endommagé.   Aviso  Trapeze Networks le recomienda que pida la ayuda de alguien para realizar los pasos restantes. Si el interruptor MX se cae accidentalmente, usted puede sufrir lesiones y el interruptor puede sufrir daños.      Warning!  To prevent the MX switch from slipping, do not release the switch until all the rack-mount screws are tight.   Waarschuwing!  Laat de MX switch niet los totdat alle bevestigingsbouten goed zijn vastgedraaid om te voorkomen dat de switch uit uw handen glijdt.   Warnung!  Sie vermeiden, dass der MX-Switch abrutscht, indem Sie ihn festhalten, bis alle Rack-Befestigungsschrauben angezogen sind.   Avertissement !  Pour éviter que le commutateur MX ne tombe, ne le lâchez pas tant que les vis de montage du châssis ne sont pas fixées.   Aviso  Para evitar que el interruptor MX se caiga, no lo suelte hasta que todos los tornillos del bastidor estén bien apretados.
Translations of Warnings and Warning Conventions         Overcurrent Warning   Warning!  The MX switch relies on the building’s installation for overcurrent protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10 A international) is used on the phase conductors.   Waarschuwing!  De MX switch is afhankelijk van de in het gebouw geïnstalleerde beveiliging tegen overstroom. Op de fase-aders dient een zekering of circuitonderbreker te worden gebruikt van maximaal 240 V~, 10 A.   Warnung!  Der Lastschutz des MX-Switch hängt vom Gesamtlastschutz des Gebäudes ab. Sie sollten sicherstellen, dass die Phasen mit maximal 240 V~ / 10 A abgesichert sind.   Avertissement !  La protection du commutateur MX contre les surintensités dépend de l’installation électrique du bâtiment. Assurez-vous qu’un fusible ou un disjoncteur inférieur ou égal à 120 VCA, 15 A É.-U. (240 VCA, 10 A pour les autres pays) est utilisé sur les conducteurs de phase.   Aviso  El interruptor MX está protegido contra las sobrecargas de corriente mediante la instalación del edificio. Asegúrese de utilizar un fusible o un disyuntor que no supere los 120 VAC, 15A en EE.UU. (240 VAC, 10 A en el resto del mundo) en los conductores de fase.                             © 2005 Trapeze Networks, Inc. All rights reserved. Trapeze Networks, the Trapeze Networks logo, the Trapeze Networks flyer icon, Mobility System, Mobility Exchange, MX, Mobility Point, MP, Mobility System Software, MSS, RingMaster, AAA Integration and RADIUS Scaling, ActiveScan, AIRS, Bonded Auth, FastRoaming, Granular Transmit Power Setting, GTPS, GuestPass, Layer 3 Path Preservation, Location Policy Rule, LPR, Mobility Domain, Mobility Profile, Passport-Free Roaming, SentryScan, Time-of-Day Access, TDA, TAPA, Trapeze Access Point Access Protocol, Virtual Private Group, VPG, Virtual Service Set, Virtual Site Survey and WebAAA are trademarks of Trapeze Networks, Inc. Trapeze Networks SafetyNet is a service mark of Trapeze Networks, Inc. All other products and services are trademarks, registered trademarks, service marks or registered service marks of their respective owners. 16