Juniper Networks 301 Dual mode 2.4GHz/5GHz Access Point User Manual Trapeze Mobility Point MP 620 Installation Guide

Juniper Networks, Inc. Dual mode 2.4GHz/5GHz Access Point Trapeze Mobility Point MP 620 Installation Guide

Manual

Part Number 730-9502-0062, Revision CTrapeze Mobility Point™MP-620 Installation Guide
ii© 2006 Trapeze Networks, Inc. All rights reserved. TrademarksTrapeze Networks, the Trapeze Networks logo, the Trapeze Networks flyer icon, Mobility System, Mobility Exchange, MX, Mobility Point, MP, Mobility System Software, MSS, RingMaster, AAA Integration and RADIUS Scaling, ActiveScan, AIRS, Bonded Auth, FastRoaming, Granular Transmit Power Setting, GTPS, GuestPass, Layer 3 Path Preservation, Location Policy Rule, LPR, Mobility Domain, Mobility Profile, Passport-Free Roaming, SentryScan, Time-of-Day Access, TDA, TAPA, Trapeze Access Point Access Protocol, Virtual Private Group, VPG, Virtual Service Set, Virtual Site Survey and WebAAA are trademarks of Trapeze Networks, Inc. Trapeze Networks SafetyNet is a service mark of Trapeze Networks, Inc. All other products and services are trademarks, registered trademarks, service marks or registered service marks of their respective owners.DisclaimerAll statements, specifications, recommendations, and technical information are current or planned as of the date of the publication of this document. They are reliable as of the time of this writing and are presented without warranty of any kind, expressed or implied. In an effort to continuously improve the product and add features, Trapeze Networks reserves the right to change any specifications contained in this document without prior notice of any kind.Comments and FeedbackYour feedback on Trapeze documentation is important to us. Send any comments and suggestions to doc-bugs@trapezenetworks.com.For the most current version of this document, see www.trapezenetworks.com. Note.  The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.Trapeze Networks, Inc.5753 W. Las Positas Blvd.Pleasanton, CA 94588Tel: +1 925-474-2200Fax: +1 925-251-0642Toll-Free: 877-FLY-TRPZ (877-359-8779)www.trapezenetworks.com
iiiCustomer ServiceFor general information about Trapeze Networks Mobility System™ products and services, visit www.trapezenetworks.com. For warranty, license, and support information, visit the following sites:●Warranty and software licenses. Current Trapeze Networks warranty and software licenses are available at www.trapezenetworks.com/services/warranty.asp.●Support services. For information about Trapeze support services, visit www.trapezenetworks.com/services/. Or call 1-866-877-9822 (in the US or Canada) or +1 925-474-2400 and select option 5. Contacting the Technical Assistance CenterContact the Trapeze Networks Technical Assistance Center (TAC) by telephone, email, or fax. If you have a service contract or are a Trapeze Authorized Partner, log in to www.trapezenetworks.com/services/sup_programs.asp for more help.●Within the US and Canada, call 1-866-TRPZTAC (1-866-877-9822).●Within Europe, call +31 35 64 78 193.●From locations outside the US and Canada, call +1 925-474-2400.●In non-emergencies, send email to support@trapezenetworks.com.●When your case is active, you can fax more information to +1 925-474-2423. Note.  TRAPEZE NETWORKS SELLS AND SERVICES ITS PRODUCTS PRIMARILY THROUGH ITS AUTHORIZED RESELLERS AND DISTRIBUTORS. If you purchased your product from an authorized Trapeze reseller or distributor and do not have a service contract with Trapeze Networks, you must contact your local reseller or distributor for technical assistance.
Trapeze MP-620 Installation GuideivTAC Response TimeTAC responds to service requests as follows: Information to Have AvailableTo expedite your service request, have the following information available when you call or write to TAC for technical assistance:●Your company name and address●Your name, telephone number, cell phone or pager number, and email address●Name, model, and serial number of the product(s) requiring service●Software version and release number●Output of the show tech-support command●Wireless client information●License levels for RingMaster™ and Mobility Exchange™ (MX™) products●Description of the problem and status of the troubleshooting effortContact method Priority Response timeTelephone Emergency One hourNon-emergency Next business dayEmail Non-emergency Next business day
Contents vContentsCustomer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  iii1  Introducing the Trapeze Networks Mobility System . . . . . . . . . . . . . . . . 1Trapeze Networks Mobility System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Documentation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Safety and Advisory Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Text and Syntax Conventions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  MP-620 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Hardware Overview  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Package Checklist   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8External Hardware Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9External Antenna Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Ethernet Port   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Power Injector Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Receive Signal Strength Indicator (RSSI) BNC Connector . . . . . . . . . . 12Grounding Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Wall- and Pole-Mounting Bracket Kits  . . . . . . . . . . . . . . . . . . . . . . . . . 12Lightning Protector for Oudoor Antenna . . . . . . . . . . . . . . . . . . . . . . . . 12System Configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Features and Benefits  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133  Installing and Connecting an MP-620 Access Point . . . . . . . . . . . . . . . . 15Installation Requirements and Recommendations  . . . . . . . . . . . . . . . . . . . . 15RingMaster Network Plan and Work Orders . . . . . . . . . . . . . . . . . . . . . 15MX Switch Recommendation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Weather Conditions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Ethernet Cabling   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Grounding   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17MP Radio Safety Advisories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Radio Frequency Exposure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Trapeze MP-620 Installation GuideviAdditional Radio Safety Advisories  . . . . . . . . . . . . . . . . . . . . . . . . 18Installing an MP-620   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Mounting the Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Using the Pole-Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . 19Using the Wall-Mounting Bracket   . . . . . . . . . . . . . . . . . . . . . . . . . 21Connecting External Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Connecting Cables to the Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Connecting the Power Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Connecting an MP to an MX Switch  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25A  MP-620 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29MP-620 Mechanical and Compliance Specifications . . . . . . . . . . . . . . . . . . 30Federal Communication Commission Interference Statement . . . . . . . . . . . 31MAC Addresses  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Antenna Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348 dBi Omnidirectional (2.4 GHz)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348 dBi Omnidirectional (5 GHz)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3613.5 dBi 120-Degree Sector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3710 dBi 120-Degree Sector  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3818 dBi 18-Degree Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Signal Loss from Lightning Protector and Coaxial Cable  . . . . . . . . . . . 41B  Cables and Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Twisted-Pair Cable Assignments  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4310/100BASE-TX Pin Assignments  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Straight-Through Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Crossover Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458-Pin DIN Connector Pinout   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468-Pin DIN to RJ-45 Cable Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Introducing the Trapeze Networks Mobility System11Introducing the Trapeze Networks Mobility SystemThis guide shows you how to install a Trapeze Networks™ Mobility Point™ (MP™) access point, model MP-620, in a Trapeze Networks Mobility System™ wireless LAN (WLAN). The MP-620 is suitable for installation outdoors.Read this guide if you are a network administrator or other person installing MP access points in a network.Trapeze Networks Mobility SystemThe Trapeze Networks Mobility System is an enterprise-class WLAN solution that seamlessly integrates with an existing wired enterprise network. The Trapeze system provides secure connectivity to both wireless and wired users in large environments such as office buildings, hospitals, and university campuses. The Trapeze Mobility System fulfills the three fundamental requirements of an enterprise WLAN: it eliminates the distinction between wired and wireless networks, allows users to work safely from anywhere (secure mobility), and provides a comprehensive suite of intuitive tools for planning and managing the network before and after deployment, greatly easing the operational burden on IT resources.Trapeze Networks Mobility System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1Documentation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
DocumentationChapter 1Trapeze MP-620 Installation Guide2The Trapeze Networks Mobility System consists of the following components:●RingMaster tool suite—A full-featured graphical user interface (GUI) application used to plan, configure, deploy, and manage a WLAN and its users●One or more Mobility Exchange™ (MX™) switches—Distributed, intelligent machines for managing user connectivity, connecting and powering Mobility Point (MP) access points, and connecting the WLAN to the wired network backbone●Multiple Mobility Point™ (MP™) access points—Wireless access points (APs) that transmit and receive radio frequency (RF) signals to and from wireless users and connect them to an MX switch●Mobility System Software™ (MSS™)—The operating system that runs all MX switches and MP access points in a WLAN, and is accessible through a command-line interface (CLI), the Web View interface, or the RingMaster GUIDocumentationConsult the following documents to plan, install, configure, and manage a Trapeze Networks Mobility System.Planning, Configuration, and DeploymentTrapeze RingMaster User’s Guide. Instructions for planning, configuring, deploying, and managing the entire WLAN with the RingMaster tool suite. Read this guide to learn how to plan wireless services, how to configure and deploy Trapeze equipment to provide those services, and how to optimize and manage your WLAN.Trapeze RingMaster Reference Manual. Detailed instructions and information for all RingMaster planning, configuration, and management features.
DocumentationChapter 1Introducing the Trapeze Networks Mobility System3Installation●Trapeze Mobility Exchange Hardware Installation Guide. Instructions and specifications for installing an MX switch●Trapeze Mobility System Software Quick Start Guide. Instructions for performing basic setup of secure (802.1X) and guest (WebAAA™) access, and for configuring a Mobility Domain for roaming●Trapeze Mobility Point MP-372 Installation Guide. Instructions and specifications for installing an MP access point and connecting it to an MX switch●Trapeze Mobility Point MP-620 Installation Guide (this document). Instructions and specifications for installing the MP-620 access point and connecting it to an MX switch●Trapeze Regulatory Information. Important safety instructions and compliance information that you must read before installing Trapeze Networks productsConfiguration and Management●Trapeze RingMaster Reference Manual. Instructions for planning, configuring, deploying, and managing the entire WLAN with the RingMaster tool suite●Trapeze Mobility System Software Configuration Guide. Instructions for configuring and managing the system through the MSS CLI●Trapeze Mobility System Software Command Reference. Functional and alphabetic reference to all MSS commands supported on MX switches and MP access points
DocumentationChapter 1Trapeze MP-620 Installation Guide4Safety and Advisory NoticesThe following kinds of safety and advisory notices appear in this manual. (For translations of the warning conventions and of all warnings in this manual, see the Trapeze Regulatory Information document.)     Caution!  This situation or condition can lead to data loss or damage to the product or other property.Warning!  This situation or condition can cause injury. Warning!  High voltage. This situation or condition can cause injury due to electric shock.Warning!  Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment.Note.  This information is of special interest.
DocumentationChapter 1Introducing the Trapeze Networks Mobility System5Text and Syntax ConventionsTrapeze manuals use the following text and syntax conventions:  Convention UseMonospace text Sets off command syntax or sample commands and system responses.Bold text Highlights commands that you enter or items you select.Italic text Designates command variables that you replace with appropriate values, or highlights publication titles or words requiring special emphasis.Menu Name > Command Indicates a menu item that you select. For example, File > New indicates that you select New from the File menu.[ ] (square brackets) Enclose optional parameters in command syntax.{ } (curly brackets) Enclose mandatory parameters in command syntax.| (vertical bar) Separates mutually exclusive options in command syntax.
DocumentationChapter 1Trapeze MP-620 Installation Guide6
MP-620 Overview72MP-620 OverviewA Trapeze Networks Mobility Point (MP) access point model MP-620 provides IEEE 802.11 wireless access to the network. MP access points are designed for use with a Trapeze Networks Mobility Exchange (MX) switch. MP access points require hardware installation only. All configuration for an MP access point takes place on the MX switch. Hardware Overview   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8External Hardware Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9System Configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12Features and Benefits   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13Warning!  Installation must be performed by qualified service personnel only. Read and follow all warning notices and instructions marked on the product or included in the documentation. Before installing the product, read the Trapeze Regulatory Information document.Note.  The MP radios are disabled by default and can be enabled only by a system administrator using the MX switch.
Hardware OverviewChapter 2Trapeze MP-620 Installation Guide8Hardware OverviewThe MP-620 provides wireless access point services for clients in the local LAN area. It is housed in a weatherproof enclosure for mounting outdoors and includes its own brackets for attaching to a wall, pole, radio mast, or tower structure. The unit is powered through its Ethernet cable connection from a power injector module that is installed indoors.Radio Characteristics – The IEEE 802.11a and 802.11g standards use a radio modulation technique known as Orthogonal Frequency Division Multiplexing (OFDM), and a shared collision domain (CSMA/CA). The 802.11a standard operates in the 5 GHz Unlicensed National Information Infrastructure (UNII) band, and the 802.11g standard in the 2.4 GHz band. IEEE 802.11g includes backward compatibility with the IEEE 802.11b standard. IEEE 802.11b also operates at 2.4 GHz, but uses Direct Sequence Spread Spectrum (DSSS) and Complementary Code Keying (CCK) modulation technology to achieve a communication rate of up to 11 Mbps.The MP-620 provides a 54 Mbps half-duplex connection for each active channel.Package ChecklistThe MP-620 package includes:●One MP-620 Mobility Point (MP) access point ●One Category 5 network cable, length 164 ft (50 m)●One power injector module and power cord●Outdoor pole-mounting bracket kit●This User Guide●Optional: Two N-type RF coaxial cables●Optional: Outdoor wall-mounting bracket kit●Optional: Lightning protector for outdoor antennaContact Trapeze Networks if there are any incorrect, missing or damaged parts. If possible, retain the carton, including the original packing materials. Use them again to repack the product in case there is a need to return it.
External Hardware FeaturesChapter 2MP-620 Overview9External Hardware FeaturesFigure 1 and Figure 2 show the external hardware features of the MP-620.Figure 1. MP Access Point Model MP-620—Bottom ViewFigure 2. MP Access Point Model MP-620—Top ViewExternal Antenna OptionsThe MP-620 unit does not include an integrated antenna, but provides various external antenna options for both 5 GHz and 2.4 GHz operation. The MP-620 unit both requires the 2.4 GHz 8 dBi omnidirectional external antenna for 2.4 GHz operation. The following table summarizes the external antenna options:Ethernet Port RSSI Connector with Protective CapGrounding Point ScrewN-Type External Antenna Connector(2.4 GHz)N-Type External Antenna Connector(5 GHz)
External Hardware FeaturesChapter 2Trapeze MP-620 Installation Guide10External antennas connect to the N-type RF connectors on the MP-620 using the provided coaxial cables.Ethernet PortThe MP-620 has one 10BASE-T/100BASE-TX 8-pin DIN port that connects to the power injector module using the included Ethernet cable. The Ethernet port connection provides power to the MP-620 as well as a data link to the local network.Table 1. External Antenna OptionsAntenna Type Gain (dBi) HPBW* HorizontalHPBW* Vertical Polarization5 GHz Omnidirectional8 360 12 Linear, vertical5 GHz 120-Degree Sector13.5 120 6 Linear, vertical5 GHz 18-Degree Panel18 18 18 Linear, vertical2.4 GHz 120-Degree Sector10 120 15 Linear, vertical2.4 GHz Omnidirectional8 360 15 Linear, vertical* Half-power beam width in degreesNote.  The power injector module does not support Power over Ethernet (PoE) based on the IEEE 802.3af standard. The MP-620 must always be powered on by being connected to the power injector module.
External Hardware FeaturesChapter 2MP-620 Overview11Power Injector ModuleThe MP-620 receives power through its network cable connection using power-over-Ethernet technology. A power injector module is included in the MP-620 package and provides two RJ-45 Ethernet ports, one for connecting to the MP-620 (Output), and the other for connecting to an MX switch or a local LAN switch (Input).The Input port uses an MDI (i.e., internal straight-through) pin configuration. You can therefore use straight-through twisted-pair cable to connect this port to most network interconnection devices such as a switch or router that provide MDI-X ports. However, when connecting the access point to a workstation or other device that does not have MDI-X ports, you must use crossover twisted-pair cable.Figure 3. Power Injector ModuleThe MP-620 does not have a power switch. It is powered on when its Ethernet port is connected to the power injector module, and the power injector module is connected to an AC power source. The power injector includes one LED indicator that turns on when AC power is applied.The power injector module automatically adjusts to any AC voltage between 100-240 volts at 50 or 60 Hz. No voltage range settings are required.Warning!  The power injector module is designed for indoor use only. Never mount the power injector outside with MP-620 unit.Input OutputEthernet and Power to MP-620LED IndicatorAC Power Socket(Hidden)Ethernet from  Local Network
System ConfigurationChapter 2Trapeze MP-620 Installation Guide12Receive Signal Strength Indicator (RSSI) BNC ConnectorThis connector is unused at this time.Grounding PointEven though the MP-620 includes its own built-in lightning protection, it is important that the unit is properly connected to ground. A grounding screw is provided for attaching a ground wire to the unit.Wall- and Pole-Mounting Bracket KitsThe MP-620 includes bracket kits that can be used to mount the unit to a wall, pole, radio mast, or part of a tower structure.Lightning Protector for Oudoor AntennaIf you are using the MP-620 with an outdoor antenna, Trapeze Networks recommends installing an external lightning protector for the antenna.System ConfigurationAt each location where an MP-620 unit is installed, it must be connected to the local network using the power injector module. The following figure illustrates the system component connections.
Features and BenefitsChapter 2MP-620 Overview13Figure 4. System Component ConnectionsFeatures and BenefitsThe MP-620 provides the following features and benefits:●The MP-620 supports access point services for the 5 GHz and 2.4 GHz radios using various external antenna options●Maximum data rate up to 108 Mbps on the 802.11a (5 GHz) radio●Outdoor weatherproof design ●IEEE 802.11a and 802.11b/g compliant ●Local network connection via 10/100 Mbps Ethernet port●Powered through its Ethernet cable connection to the power injector module●Includes wall- and pole-mount brackets●Security through 64/128/152-bit Wired Equivalent Protection (WEP) or 128-bit Advanced Encryption Standard (AES) encryption●Scans all available channels and selects the best channel and data rate based on the signal-to-noise ratioIndoor OutdoorLAN SwitchAC PowerPowerInjectorMP-620 UnitGround WireEthernet Cable Ethernet CableExternal AntennaRF Coaxial CableLightningProtector
Features and BenefitsChapter 2Trapeze MP-620 Installation Guide14
Installing and Connecting an MP-620 Access Point153Installing and Connecting an MP-620 Access PointInstallation Requirements and RecommendationsFor best results, follow these requirements and recommendations before installing an MP-620 access point.RingMaster Network Plan and Work OrdersIf you are using RingMaster to plan your Trapeze Networks Mobility System installation, you might want to create and verify a network plan for the entire Trapeze network installation and generate an MP work order, before installing MP access points. A network plan and the MP work orders generated from it provide the following information about MP access point installation and configuration:Installation Requirements and Recommendations  . . . . . . . . . . . . . . . . . . . . .  15Installing an MP-620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19Connecting an MP to an MX Switch   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  25Note.  Before installing an MP access point, you might need to generate a network plan and an MP work order with RingMaster. (See “RingMaster Network Plan and Work Orders” on page 15.)
Installation Requirements and RecommendationsChapter 3Trapeze MP-620 Installation Guide16●Number of MP access points required for adequate WLAN capacity in each coverage area●Detailed installation location for each MP access point●Settings for all MP access points in the WLAN(For information about installing RingMaster, creating and verifying a network plan, and generating an MP work order, see the Trapeze RingMaster User’s Guide and Trapeze RingMaster Reference Manual.)MX Switch RecommendationTrapeze Networks recommends that you install and configure the MX switch before installing an MP access point. If the switch is already installed and configured for the MP access point(s), you can immediately verify the cable connection(s) when you plug the cable(s) into the MP access point.(For information about connecting an MP access point to an MX switch port, see “Connecting an MP to an MX Switch” on page 25.)Weather ConditionsWhen planning an MP-620 installation, you must take into account any extreme weather conditions that are known to affect your location. Consider these factors:●Temperature — The MP-620 is tested for normal operation in temperatures from -33°C to 55°C. Operating in temperatures outside of this range may cause the unit to fail. ●Wind Velocity — The MP-620 can operate in winds up to 90 MPH and survive higher wind speeds up to 125 MPH. You must consider the known maximum wind velocity and direction at the site and be sure that any supporting structure, such as a pole, mast, or tower, is built to withstand this force.Caution!  MP model MP-620 is designed to receive power only from a Trapeze-approved power injector. Connecting an MP access point to a Power over Ethernet (PoE) device that is not approved by Trapeze Networks can damage the equipment.
Installation Requirements and RecommendationsChapter 3Installing and Connecting an MP-620 Access Point17●Lightning — The MP-620 includes its own built-in lightning protection. However, you should make sure that the unit, any supporting structure, and cables are all properly grounded. Additional protection using lightning rods, lightning arrestors, or surge suppressors may also be employed. ●Rain — The MP-620 is weatherproofed against rain. Also, prolonged heavy rain has no significant effect on the radio signal. However, it is recommended to apply weatherproof sealing tape around the Ethernet port and antenna connectors for extra protection. If moisture enters a connector, it may cause a degradation in performance.●Snow and Ice — Falling snow, like rain, has no significant effect on the radio signal. However, a build up of snow or ice on antennas may cause a degradation in performance. In this case, the snow or ice has to be cleared from the antennas to restore proper operation of the unit.Ethernet CablingWhen you have determined a suitable location for the MP-620, you must plan a cable route from the MP-620 outdoors to the power injector module indoors. Consider these points:●The Ethernet cable length should never be longer than 100 m (328 ft)●Determine a building entry point for the cable●Determine if conduits, bracing, or other structures are required for safety or protection of the cable●For lightning protection at the power injector end of the cable, consider using a lightning arrestor immediately before the cable enters the buildingGroundingIt is important that the MP-620 unit, cables, lightning protectors, and any supporting structures are properly grounded. The MP-620 unit includes a grounding screw for attaching a ground wire. Be sure that grounding is available and that it meets local and national electrical codes.
Installation Requirements and RecommendationsChapter 3Trapeze MP-620 Installation Guide18MP Radio Safety AdvisoriesWhen you enable the MP radio(s) as part of MX switch configuration, the radios are able to receive and transmit radio frequency energy as soon as you connect the MP access point(s) to the MX switch, either directly or through the network. Radio Frequency ExposureFederal Communications Commission (FCC) Docket 96-8 for Spread Spectrum Transmitters specifies a safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC-certified equipment. When used with the proper antennas (shipped in the product), Trapeze Networks MP access point products meet the uncontrolled environmental limits found in OET-65 and ANSI C95.1-1991. Proper installation of the MP access point according to the instructions in this manual will result in user exposure that is below the FCC recommended limits.Additional Radio Safety AdvisoriesFor additional radio safety warnings, the Trapeze Regulatory Information document.
Installing an MP-620Chapter 3Installing and Connecting an MP-620 Access Point19Installing an MP-620The MP-620 includes its own bracket kit for mounting the unit to a 1.5 to 2 inch diameter steel pole or tube. The pole-mounting bracket allows the unit to be mounted to part of a radio mast or tower structure. The unit also has a wall-mounting bracket kit that enables it to be fixed to a building wall or roof when using external antennas.Hardware installation of the MP-620 involves these steps:1Mount the unit on a wall, pole, mast, or tower using the mounting bracket.2Mount external antennas on the same supporting structure as the MP-620 and connect them to the unit.3Connect the Ethernet cable and a grounding wire to the unit.4Connect the power injector to the Ethernet cable, a local LAN switch, and an AC power source.Mounting the UnitYou can mount the MP-620 using either the pole-mounting bracket or the wall-mounting bracket. Use one of the following procedures.Using the Pole-Mounting BracketPerform the following steps to mount the unit to a 1.5 to 2 inch diameter steel pole or tube using the mounting bracket:1Always attach the bracket to a pole with the open end of the mounting grooves facing up.2Place the U-shaped part of the bracket around the pole and tighten the securing nut just enough to hold the bracket to the pole. (The bracket may need to be rotated around the pole during the alignment process.)
Installing an MP-620Chapter 3Trapeze MP-620 Installation Guide20Figure 5. Attaching the Bracket to the Pole3Use the included nuts to tightly secure the MP-620 to the bracket. Mounting on Larger Diameter PolesIn addition, there is a method for attaching the pole-mounting bracket to a pole that is 2 to 5 inches in diameter using an adjustable steel band clamp (not included in the kit). A steel band clamp up to 0.5 inch (1.27 cm) wide can be threaded through the main part of the bracket to secure it to a larger diameter pole without using the U-shaped part of the bracket. This method is illustrated in the following figure.Figure 6. Attaching the Bracket Using a Steel Band ClampAttach bracket to pole with mounting grooves facing upSteel Band Clamp
Installing an MP-620Chapter 3Installing and Connecting an MP-620 Access Point21Using the Wall-Mounting BracketPerform the following steps to mount the unit to a wall using the wall-mounting bracket:1Always attach the bracket to a wall with the open end of the mounting grooves facing up (see following figure).Figure 7. Wall-Mounting Bracket2Position the bracket in the intended location and mark the position of the three mounting screw holes.3Drill three holes in the wall that match the screws and wall plugs included in the bracket kit, then secure the bracket to the wall.4Use the included nuts to tightly secure the MP-620 to the bracket. Connecting External AntennasWhen deploying an MP-620 access point, you need to mount external antennas and connect them to the unit. Typically, access point operation requires a 2.4 GHz antenna.Perform these steps:1Mount the external antenna to the same supporting structure as the MP-620, within 3 m (10 ft) distance, using the bracket supplied in the antenna package.2If you are installing the optional lightning protector for an outdoor antenna, perform the following steps. Otherwise, skip to step 3.Mounting Grooves
Installing an MP-620Chapter 3Trapeze MP-620 Installation Guide22aSolder the grounding cable to the grounding nut supplied with the lightning protector. Trapeze Networks recommends that you use 6-gauge cable for the grounding cable. The grounding cable must be properly earthed in order to provide adequate protection.bAttach the grounding nut, locking washer, and hex nut to the lightning protector, in the order shown in Figure 8.Figure 8. Attaching the Grounding Nut, Locking Washer, and Hex Nut to the Optional Lightning ProtectorcConnect one end of the short RF coaxial cable to the MP-620’s N-type connector, and connect the other end to the lightning protector.dConnect one end of the 3m RF coaxial cable to the lightning protector, and connect the other end to the outdoor antenna. Continue with step 4.3Connect the antenna to the MP-620’s N-type connector using the RF coaxial cable provided in the antenna package.4Apply weatherproofing tape to the antenna connectors to help prevent water entering the connectors.To External AntennaTo MP-6206-gaugeGrounding CableGrounding NutLocking WasherHex NutLightning Protector
Installing an MP-620Chapter 3Installing and Connecting an MP-620 Access Point23Figure 9. Connecting External Antennas to the MP-620Connecting Cables to the Unit1Attach the Ethernet cable to the Ethernet port on the MP-620. 2For extra protection against rain or moisture, apply weatherproofing tape (not included) around the Ethernet connector.3Be sure to ground the unit with an appropriate grounding wire (not included) by attaching it to the grounding screw on the unit.Note.  The Ethernet cable included with the package is 30 m (100 ft) long. To wire a longer cable (maximum 100 m, 325 ft), use the connector pinout information in Appendix B.Caution!  Be sure that grounding is available and that it meets local and national electrical codes. For additional lightning protection, use lightning rods, lightning arrestors, or surge suppressors.MP-620
Installing an MP-620Chapter 3Trapeze MP-620 Installation Guide24Figure 10. Attaching an Ethernet Cable to the MP-620Connecting the Power InjectorTo connect the MP-620 to a power source: 1Connect the Ethernet cable from the MP-620 to the RJ-45 port labeled “Output” on the power injector.2Connect a straight-through unshielded twisted-pair (UTP) cable from a local LAN switch to the RJ-45 port labeled “Input” on the power injector. Use Category 5 or better UTP cable for 10/100BASE-TX connections.Caution!  Do not install the power injector outdoors. The unit is for indoor installation only.Note.  The MP-620’s Ethernet port does not support Power over Ethernet (PoE) based on the IEEE 802.3af standard. Do not try to power the unit by connecting it directly to a network switch that provides IEEE 802.3af PoE. Always connect the unit to the included power injector module.Note.  The RJ-45 port on the power injector is an MDI port. If connecting directly to a computer for testing the link, use a crossover cable.Ground WireEthernet Cable
Connecting an MP to an MX SwitchChapter 3Installing and Connecting an MP-620 Access Point25Figure 11. Connecting Cables to the Power Injector3Insert the power cable plug directly into the standard AC receptacle on the power injector.4Plug the other end of the power cable into a grounded, 3-pin socket, AC power source.5Check the LED on top of the power injector to be sure that power is being supplied to the MP-620 through the Ethernet connection.Connecting an MP to an MX SwitchYou can connect an MP access point directly to an MX switch or indirectly to the switch through an intermediate Layer 2 or Layer 3 network. ●To connect the MP directly to an MX switch, configure the MX switch port as an MP access port and use the following procedure to insert the cable into the MX switch and verify the link. ●To connect the MP indirectly to an MX switch though the network, configure a Distributed MP connection on the MX switch. Note.  For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the receptacle type in your country.Input OutputEthernet cable from LAN switchEthernet cable to MP-620AC powerPower LED indicator
Connecting an MP to an MX SwitchChapter 3Trapeze MP-620 Installation Guide26You can use the CLI or RingMaster to configure an MP access port or Distributed MP connection. (See the Trapeze Mobility System Software Configuration Guide or the Trapeze RingMaster User’s Guide.)Figure 12 shows how to insert a Cat 5 cable into 10/100 Ethernet port on an MX switch. Refer to this figure as you perform the procedure. Figure 12. 10/100 Cat 5 Cable InstallationMobility ExchangeMX-20Ethernet cable (Cat 5 cable) MP, switch, server or other device840-9502-0058Ethernet port
Connecting an MP to an MX SwitchChapter 3Installing and Connecting an MP-620 Access Point271Insert a Cat 5 cable with a standard RJ-45 connector as shown in Figure 12. For connection to an MP access point, use a straight-through cable.2When the link is activated, observe the MP LED for the port on the MX switch:MX Switch’s MP LED MeaningSolid green For an MP access point’s active link, all the following are true:• MP access point has booted.• MP access point has received a valid configuration from the MX switch.• Management link with an MP access point is operational.• At least one radio is enabled or is in sentry mode.For an MP access point’s secondary link, the link is present.Alternating green and amberMP access point is booting with an image received from the MX switch. After the access point boots and receives its configuration, this LED appearance persists until a radio is enabled or is placed in sentry mode.Solid amber PoE is on.Blinking amber MP is unresponsive or there is a PoE problem.Unlit PoE is off.Note.  An MX switch’s 10/100 Ethernet ports are configured as wired network ports by default. You or the system administrator must change the port type for an MX port directly connected to an MP to activate the link. (See the Trapeze Mobility Exchange Installation and Basic Configuration Guide.)
Connecting an MP to an MX SwitchChapter 3Trapeze MP-620 Installation Guide28
MP-620 Technical Specifications29AMP-620 Technical SpecificationsThis appendix lists the technical specifications for the Trapeze Networks MP-620 access point. Table 2 lists the mechanical and compliance specifications. (For detailed compliance information, see the Trapeze Regulatory Information document.) Table 3 lists the MAC address allocation scheme. The remaining tables list the specifications and link budgets for the external antennas. (For specifications for the MX switch, see the Trapeze Mobility Exchange Installation and Basic Configuration Guide.)   Note.  This Listed Accessory is designed and approved to be used only with Trapeze Networks Mobility Exchange (MX) models MX-20, MX-8, MX-216, and MXR-2. (The MX-200 and MX-400 switches do not directly connect to the MP.)Note.  The MP radios are disabled by default and can be enabled only by the system administrator using the RingMaster management application or the MX switch’s command-line interface (CLI). Note.  The radio frequency band, operating channels, and transmit power depend on the country of operation specified by the system administrator using RingMaster or the MX switch’s CLI.
MP-620 Mechanical and Compliance SpecificationsAppendix ATrapeze MP-620 Installation Guide30MP-620 Mechanical and Compliance SpecificationsTable 2 lists the mechanical and compliance specifications for the MP-620.Table 2. MP-620 Mechanical and Compliance SpecificationsSpecification DescriptionMaximum Channels (Outdoor)Based on the country of operation specified by the system administratorData Rates 802.11a:6, 9, 12, 18, 24, 36, 48, 54 Mbps per channel802.11g: 6, 9, 11, 12, 18, 24, 36, 48, 54 Mbps per channel802.11b: 1, 2, 5.5, 11 Mbps per channelMaximum Clients 64 for the radio interface set to access point modeModulation Types 802.11a: BPSK, QPSK, 16-QAM, 64-QAM802.11g: CCK, BPSK, QPSK, OFDM802.11b: CCK, BPSK, QPSKNetwork Configuration Access Point Mode:   InfrastructureOperating Frequency 802.11a:5.15 GHz to 5.825 GHz based on country regulations802.11b/g:2.4 GHz to 2.4835 GHz based on country regulationsPower Injector Input: 100-240 VAC, 47-63 Hz, 1.5 AOutput: 48 VDC, 1.2 APhysical Size 19.8 x 19.8 x 6.33 cm (7.8 x 7.8 x 2.49 in)Weight 4.8 kg (10.58 lbs)Temperature Operating: -33 to 55 °C (-27.4 to 131 °F)Storage: -40 to 80 °C (-40 to 176 °F)
Federal Communication Commission Interference StatementAppendix AMP-620 Technical Specifications31Federal Communication Commission Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:●Reorient or relocate the receiving antenna.●Increase the separation between the equipment and receiver.Humidity 5% to 95% (non-condensing)EMC Compliance (Class B) FCC Class B (US)RTTED 1999/5/ECDGT (Taiwan)Radio Signal Certification FCC Part 15 15.407(b) (5 GHz)FCC Part 15.247 (2.4 GHz)IC RSS-210EN 300.328, EN 302.893EN 300 826, EN 301.489-1, EN 301.489-17ETSI 300.328; ETS 300 826 (802.11b)Safety                                      UL/cUL60950-1, IEC60950-1 (CB), IP68 (NEMA-250 6P)Standards IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.11a, b, gTable 2. MP-620 Mechanical and Compliance Specifications Specification Description
Federal Communication Commission Interference StatementAppendix ATrapeze MP-620 Installation Guide32●Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.●Consult the dealer or an experienced radio/TV technician for help.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.For operation within 5.15 ~ 5.25GHz frequency range, it is restricted to indoor environment.IMPORTANT NOTE:FCC Radiation Exposure Statement:This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.IEEE 802.11b or 802.11g operation of this product in the U.S.A. is firmware-limited to channels 1 through 11.
MAC AddressesAppendix AMP-620 Technical Specifications33MAC AddressesEach MP-620 is assigned a unique block of 64 MAC addresses. Each radio has 32 MAC addresses and can therefore support up to 32 SSIDs, with one MAC address assigned to each SSID as its BSSID.An MP’s MAC address block is listed on a label on the back of the MP. If the MP is already deployed and running on the network, you can display the MAC address assignments by using the show {ap | dap} status command.All MAC addresses on an MP are assigned based on the MP’s base MAC address, as described in Table 3.Table 3. MAC Address Allocations on MP-620MP base MAC Address• The MP has a base MAC address. All the other addresses are assigned based on this address. Ethernet Port MAC Addresses• The Ethernet port equals the MP base MAC address.802.11a Radio and SSID MAC Addresses• The 802.11a radio equals the MP base MAC address + 1.• The BSSIDs for the SSIDs configured on the 802.11a radio end in odd numbers. The first BSSID is equal to the MP’s base MAC address + 1. The next BSSID is equal to the MP’s base MAC address + 3, and so on. 802.11b/g Radio and SSID MAC Addresses• The 802.11b/g radio equals the MP base MAC address. • The BSSIDs for the SSIDs configured on the 802.11b/g radio end in even numbers. The first BSSID is equal to the MP’s base MAC address. The next BSSID is equal to the MP’s base MAC address + 2, and so on.
Antenna SpecificationsAppendix ATrapeze MP-620 Installation Guide34Antenna Specifications8 dBi Omnidirectional (2.4 GHz)Table 4. 8 dBi Omnidirectional (2.4 GHz) Antenna SpecificationsSpecification DescriptionModel Number ANT-1360-OUTFrequency Range 2.400 - 2.500 GHzGain 8 dBiVSWR 2.0 : 1 maxPolarization Linear, verticalHPBW Horizontal: 360°Downtilt 0°Power Handling 50 W (cw)Impedance 50 OhmsConnector N type, maleRadome Material: Fiber glassColor: Gray-white
Antenna SpecificationsAppendix AMP-620 Technical Specifications35Environmental Survival Wind Speed: 216 km/hrTemperature: -40 °C to 80 °CHumidity: 95% @ 25 °CMechanical Dimensions: 58 x 2.1 cm (diameter) (22.8 x 0.82 in)Weight: 200 g (0.44 lbs) Table 4. 8 dBi Omnidirectional (2.4 GHz) Antenna Specifications Specification Description
Antenna SpecificationsAppendix ATrapeze MP-620 Installation Guide368 dBi Omnidirectional (5 GHz)Table 5. 8 dBi Omnidirectional (5 GHz) Antenna SpecificationsSpecification DescriptionModel Number ANT-5360-OUTFrequency Range 5.725 - 5.875 GHzGain 8 dBiVSWR 2.0 : 1 maxPolarization Linear, verticalHPBW Horizontal: 360°Downtilt 0°Power Handling 5 W (cw)Impedance 50 OhmsConnector N type, femaleRadome Material: Fiber glassColor: Gray-whiteEnvironmental Survival Wind Speed: 216 km/hrTemperature: -40 °C to 80 °CHumidity: 95% @ 25 °CMechanical Dimensions: 32.5 x 2.2 cm diameter (12.8 x 8.6 in)Weight: 1100 g (2.4 lbs)
Antenna SpecificationsAppendix AMP-620 Technical Specifications3713.5 dBi 120-Degree SectorTable 6. 13.5 dBi 120-Degree Sector Antenna SpecificationsSpecification DescriptionModel Number ANT-5120-OUTFrequency Range 5.150 - 5.875 GHzGain 13.5 dBiVSWR 2.0 : 1 maxPolarization Linear, verticalHPBW Horizontal: 120°Vertical: 6°Downtilt 0°Power Handling 5 W (cw)Impedance 50 OhmsConnector N type, femaleRadome Material: ABSColor: Gray, whiteEnvironmental Survival Wind Speed: 216 km/hrTemperature: -40 °C to 80 °CHumidity: 95% @ 25 °CMechanical Dimensions: 62 x 8.8 x 7 cm (24.4 x 3.46 x 2.76 in)Weight: 590 g (1.3 lbs)
Antenna SpecificationsAppendix ATrapeze MP-620 Installation Guide3810 dBi 120-Degree SectorTable 7. 10 dBi 120-Degree Sector Antenna SpecificationsSpecification DescriptionModel Number ANT-1120-OUTFrequency Range 2.4 - 2.5 GHzGain 10 dBiVSWR 2.0 : 1 maxPolarization Linear, verticalHPBW Horizontal: 120°Vertical: 15°Downtilt 0°Power Handling 10 W (cw)Impedance 50 OhmsConnector N type, femaleRadome Material: ABSColor: Gray, white
Antenna SpecificationsAppendix AMP-620 Technical Specifications39Environmental Survival Wind Speed: 216 km/hrTemperature: -40 °C to 80 °CHumidity: 95% @ 25 °CMechanical Dimensions: 75 x 8.8 x 7 cm (29.5 x 3.46 x 2.76 in)Weight: 700 g (1.5 lbs) Table 7. 10 dBi 120-Degree Sector Antenna Specifications Specification Description
Antenna SpecificationsAppendix ATrapeze MP-620 Installation Guide4018 dBi 18-Degree PanelTable 8. 18 dBi 18-Degree Panel Antenna SpecificationsSpecification DescriptionModel NumberFrequency Range 4.9 - 5.875 GHzGain 18 dBiVSWR 2.0 : 1 maxPolarization Linear, verticalHPBW Horizontal: 18°Vertical: 18°Downtilt 0°Power Handling 5 W (cw)Impedance 50 OhmsConnector N type, femaleRadome Material: ABSColor: Gray, white
Antenna SpecificationsAppendix AMP-620 Technical Specifications41Signal Loss from Lightning Protector and Coaxial CableEnvironmental Survival Wind Speed: 216 km/hrTemperature: -40 °C to 80 °CHumidity: 95% @ 25 °CMechanical Dimensions: 21.5 x 20 x 5 cm (8.46 x 7.87 x 1.97 in)Weight: 825 g (1.82 lbs) Frequency Loss from Lightning ProtectorLoss from3m cableLoss from1.8m cableLoss from0.3m cable2.4 GHz 0.08 dBi 0.75 dBi 0.59 dBi 0.24 dBi5.5 GHz 0.25 dBi 1.17 dBi 0.89 dBi 0.37 dBiTable 8. 18 dBi 18-Degree Panel Antenna Specifications (continued)Specification Description
Antenna SpecificationsAppendix ATrapeze MP-620 Installation Guide42
Cables and Pinouts43BCables and PinoutsThis appendix describes the wiring and pin assignments for the cables and connectors that can be used with the MP-620.Twisted-Pair Cable AssignmentsFor 10/100BASE-TX connections, a twisted-pair cable must have two pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be green and the other, green with white stripes. Also, an RJ-45 connector must be attached to both ends of the cable.  The following figure illustrates how the pins on the RJ-45 connector are numbered. Be sure to hold the connectors in the same orientation when attaching the wires to the pins.Caution!  Each wire pair must be attached to the RJ-45 connectors in a specific orientation.Caution!  DO NOT plug a phone jack connector into a power injector RJ-45 port. Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards.
Twisted-Pair Cable AssignmentsAppendix BTrapeze MP-620 Installation Guide44Figure 13. Pin Numbering on RJ-45 Connector10/100BASE-TX Pin AssignmentsUse unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or 100-ohm Category 5 or better cable for 100 Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).The RJ-45 Input port on the power injector is wired with MDI pinouts. This means that you must use crossover cables for connections to PCs or servers, and straight-through cable for connections to switches or hubs. However, when connecting to devices that support automatic MDI/MDI-X pinout configuration, you can use either straight-through or crossover cable.Table 9. 10/100BASE-TX MDI and MDI-X Port PinoutsPin MDI-X Signal Name MDI Signal Name1 Receive Data plus (RD+) Transmit Data plus (TD+)2 Receive Data minus (RD-) Transmit Data minus (TD-)3 Transmit Data plus (TD+) Receive Data plus (RD+)6 Transmit Data minus (TD-) Receive Data minus (RD-)4,5,7,8Not used Not usedNote: The “+” and “-” signs represent the polarity of the wires that make up each wire pair.1881
Twisted-Pair Cable AssignmentsAppendix BCables and Pinouts45Straight-Through WiringBecause the 10/100 Mbps Input port on the power injector uses an MDI pin configuration, you must use “straight-through” cable for network connections to hubs or switches that only have MDI-X ports. However, if the device to which you are connecting supports automatic MDI/MDI-X operation, you can use either “straight-through” or “crossover” cable.Figure 14. Straight-Through Cable WiringCrossover WiringBecause the 10/100 Mbps port on the power injector uses an MDI pin configuration, you must use “crossover” cable for network connections to PCs, servers or other end nodes that only have MDI ports. However, if the device to which you are connecting supports automatic MDI/MDI-X operation, you can useeither “straight-through” or “crossover” cable.Figure 15. Crossover Cable WiringWhite/Orange StripeOrangeWhite/Green StripeGreen1234567812345678EIA/TIA 568B RJ-45 WiringStandard10/100BASE-TX Straight-through CableEnd A End BBlueWhite/Blue StripeBrownWhite/Brown StripeWhite/Orange StripeOrangeWhite/Green Stripe1234567812345678EIA/TIA 568B RJ-45 WiringStandard10/100BASE-TX Crossover CableEnd A End BGreenBlueWhite/Blue StripeBrownWhite/Brown Stripe
8-Pin DIN Connector PinoutAppendix BTrapeze MP-620 Installation Guide468-Pin DIN Connector PinoutThe Ethernet cable from the power injector connects to an 8-pin DIN connector on the MP-620. This connector is described in the following figure and table.Figure 16. 8-Pin Ethernet DIN ConnectorTable 10. 8-Pin DIN Ethernet Port PinoutPin Signal Name1 Transmit Data plus (TD+)2 Transmit Data minus (TD-)3 Receive Data plus (RD+)4 +48 VDC power5 +48 VDC power6 Receive Data minus (RD-)7 Return power8 Return powerNote: The “+” and “-” signs represent the polarity of the wires that make up each wire pair.17234586
8-Pin DIN Connector PinoutAppendix BCables and Pinouts478-Pin DIN to RJ-45 Cable WiringTo construct an extended Ethernet cable to connect from the power injector’s RJ-45 Output port to the MP-620’s 8-pin DIN connector, follow the wiring diagram below. Use Category 5 or better UTP or STP cable, maximum length 100 m (328 ft), and be sure to connect all four wire pairs.Figure 17. 8-Pin DIN to RJ-45 Cable WiringNote.  To construct a reliable Ethernet cable, always use the proper tools or ask a professional cable supplier to construct the cable.White/Orange StripeOrangeWhite/Green StripeGreen12345678123456788-Pin DINFemale RJ-4517234586White/Blue StripeWhite/Brown StripeBrownBlue8-Pin DIN FemaleFront View
8-Pin DIN Connector PinoutAppendix BTrapeze MP-620 Installation Guide48
Index49IndexAaccess point. See MP (Mobility Point)activating an MP  25advisory notices, explanations of  4Ccableassignments 43crossover 45straight-through 45channels, maximum  30clients, maximum  30connectionsLEDs 27MX (Mobility Exchange)  25conventions, text and syntax  5crossover cable  45CSMA/CA 8customer service  iiiDdata rate, options  30documentation conventions  5documentation, product  2EEthernetconnections to an MX switch, instructions 25LEDs 27port 10Hhardwarebottom view  9features 9top view  9IIEEE 802.11a  8installationMP 15, 19requirements 15warnings, radio  18warnings, service  7IP addresses  33LLEDsMP (on MX)  27linksLEDs 27MP 27MMAC addresses  33manuals, product  2MDI, RJ-45 pin configuration  11Mobility Exchange. See MXMobility Point. See MPMP (Mobility Point)description of  7installation 15, 19specifications 29
Trapeze MP-620 Installation Guide50MX (Mobility Exchange)connections 25MP LEDs  27recommendation 16Nnetwork plan, RingMaster  15OOFDM 8operating frequency  30Ppackage checklist  8PoE 24PoE (Power over Ethernet)use with Trapeze devices only  16Power over Ethernet See  PoEpower supply, specifications  30product documentation  2Rradiosdefault state  7specifications 29warnings 18requirements 15reset button  11RingMasterwork order  15RSSI BNC  12Ssafety notices, explanations of  4specifications 29straight-through cable  45switch. See MX (Mobility Exchange)syntax conventions  5TTAC (Technical Assistance Center)  iiiTechnical Assistance Center  iiitechnical specifications  29technical support  iiiTrapeze customer service  iiiTrapeze Networks Mobility System  1Wwarningsinstallation 7radio 18weather conditions  16work order, RingMaster  15

Navigation menu