K Rain 3208WRFS Wireless Rain-Freeze Sensor User Manual

K-Rain Manufacturing Corporation Wireless Rain-Freeze Sensor

Users Manual

RainSensorSuspendsAutomaticIrrigationSystemSavewaterandhelptheenvironment,suspendingyourirrigationsystemonrainydayswithanyoftheK‐Rainrainsensors.Owner’sManualandInstallationInstructions3208‐WRFSWirelessRainFreezeSensor3208‐HRFSRainFreezeSensor3208‐HRSRainSensor
IntroductionThankyouforselectingaK‐Rain®RainSensor.Thissensorwilldohispartforagreenerfutureongenerationstocomebyefficientuseofwater,providingwaterconservation,easeofuse,andflexibilitytoyourprogrammablewateringsystem.Savewaterandhelptheenvironmentsuspendingyourirrigationsystemonrainydays.Afterasetamountofrainhasfallenand/orfreezingtemperaturesexist,thesensorwilltriggerpreventingthecontrollerfromstartirrigation.Forunitswithfreezesensor,theyprovidepeaceofmind(whentemperaturedropsbelow37°F[3°C])byinterruptingyoursprinklersandreducethehazardsofstandingwaterfreezingonyourdriveway,sidewalks,andpatios.Oncetherainsensorhasdriedsufficiently,thesensorallowsnormalsprinkleroperation.Workswithmostnewandexistingsprinklersystems.ThisrainsensorwillNOTworkwithopencircuittimers.Thesesensorsaredesignedtooperatewith24VACpoweronly.Connectinganyoftheserainsensorsto120or240VACpowermayresultinsevereequipmentdamage.TableofContentsFeatures ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐RainSensorComponents ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Installation ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐AdjustmentsandOperation ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Specifications ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐FCCNotice ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐FCCDeclarationofConformity ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐Notes ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Features Weatherresistant.EngineeredwithUVresistantpolymerforoutdoorexposure. MaintenanceFree.Nobatteriestoreplace.PeaceofmindforuptotenyearsNote:Undernormalconditions. UnlikeotherRainSensorsinthemarket,ourmodel3208‐WRFS(K‐Rainwirelessrain‐freezesensor)canbepairedwithmultipleK‐RainProEXControllerswithinrange,providingadditionalvaluefortheenduser. 2in1Mounting.Providesflexibleinstallationtotheuserwithstandardflatandguttermounting. Themodels3208‐WRFSand3208‐HRFSincludeafreezesensor,thatpreventstheirrigationsystemfromstartingwhentemperaturesdropto37Fofbelow. QuickInstallation.Simple,easyandhasslefreeinallofourmodels.a. TheWirelessRain‐FreezeSensor3208‐WRFSprovidestheadvantageofextremelyquickinstallationandeliminatesunsightlywiresasnowiresinstallationisneeded.RainSensorComponents1‐ ManualTestPin.Pressandholdthemanualtestpintoconfirmproperoperation.2‐ VentAdjustmentTab.Usedtoadjustthedryouttimeforthesensor.3‐ MountingArm.Metalextensionarmformountingthesensor.4‐ RainfalladjustmentCap.Therainsensorcapcanbeadjustedtosuspendwatering,whenrainfallamountsof1/8"(minimumsetting)and1/2"ormorehasfallen.5‐ FreezeSensor(formodels3208‐WRFSand3208‐HRFSonly).Preventstheirrigationsystemfromstartingwhentemperaturesdropto37Fofbelow.Whentemperaturesriseabove37F,thesensorwillenableautomaticwatering.AdditionalComponentsoftheWirelessRain‐FreezeSensormodel3208‐WRFS:6‐ RadioAntenna.Transmitsawirelesssignaltothereceiver,upto500feet.Note:Unitneedstobemounted,havingtheradioantennaonverticalposition.7‐ Battery/TransferSignalLED.PressingtheManualTestPin,allowstheusertoseetheLEDflashingON/Off;indicatingthatthebatteryisstillalivealsothatisstilltransmittingthesignaltoreceiver.Installation
Formodel3208‐WRFSWirelessRainFreezeSensor1. InstalltheRFMreceiver(Model3206)intoyourProEXController.2. Pairyour3208WirelessRain‐FreezeSensorwiththeProEXController.Placedialonpinposition.PressUPbuttonuntiltheword“LEARN”isdisplayedintotheLCD.PresstheSTARTbutton,anduserwillseetheword“LEARN”flashing.Pressthemanualtestpin(FOR3SECONDS)forthewirelessrainsensortotransmitthesignal.
Thecontrollerwilldisplay“LEARNED”oncethewirelessrainsensorhasbeenpaired.PresstheDOWNbuttontocompletetheprocess.MovethedialbacktoAUTO.InstallationWIRING‐Formodel3208‐HRFS(RainFreezeSensor)or3208‐HRS(RainSensor)IMPORTANT:Therainsensorissoldanddesignedfor24‐VACirrigationcontrollersonly.Allwiringmust
conformtoapplicablelocalcodes.WiringthewiredrainsensorsintoControllerswithSensorTerminals,simply: Findthecontrollersensorterminals(generallymarked“SENSOR”,“SEN”or“S”)andattachtheRainSensorcontrolwiresdirectlytotheseterminalsinanyorder.NOTE:1. Theremaybeajumpertaborwirebetweenthesensorterminalsthatmustberemoved.2. Ifarainsensorwillnotbeinstalled,thepreinstalledjumperwiremustremaininstalledontheSENSORterminals.Wiringthewiredrainsensors3208‐HRFS(RainFreezeSensor)or3208‐HRS(RainSensor)intocontrollerswithnosensorterminalsandnopumpstart/mastervalve:.
A. 24‐VACSolenoidValvesOnly(NoPumpStartRelaySeeFigure1).Withthetwowiresfromtherainsensoratthecontroller,locatethe“commonground”wireofthesolenoidvalves.Ifitisconnectedtothecommonterminalonthecontrollerdisconnectit.Attachonewireoftherainsensortothe“common”terminal(usuallymarked“COM”)onthecontroller.Attachtheotherwireoftherainsensortothecommonwireleadingtothevalves.Note:Thecommonwiretothevalvesdoesnothavetobeinterruptedatthecontroller.Therainsensormaybewiredanywherealongthecommonwireline.Oncetherainsensorismounted,runthewiretothecontroller,usingwireclipseveryfewfeettofastenit.Ifanextensiontothewireprovidedisneeded,usethefollowingtabletodeterminetheminimumwiregaugeneeded:CHECKTOVERIFYCORRECTWIRINGTurnononezoneofthesprinklersystemthatisvisiblewhileyouareinreachoftherainsensor.Manuallydepressthemanualtestpinatthetopoftherainsensoruntilyouheartheswitch“click”off.Thesprinklerzoneshouldstopinstantly.Ifitdoesnot,checkwiringforcorrectinstallation.Wiringthewiredrainsensors3208‐HRFS(RainFreezeSensor)or3208‐HRS(RainSensor)intocontrollerswithpumpstart/mastervalveterminal;andnosensorterminals:
B.24‐VACSolenoidValveswithPumpStartRelay(SeeFigure2).Locatethecommonwiretothesolenoidvalvesandthecommonwireleadtothecoiloftherelaythatstartsthepump.Ifthesetwowiresareconnectedtothe“common”terminalonthecontroller,disconnectbothofthem.Twistthesetwowirestogetheralongwithonewirefromtherainsensorandsecurewithawirenut.Attachtheotherwireoftherainsensortothe“common”terminalonthecontroller.Oncetherainsensorismounted,runthewiretothecontroller,usingwireclipseveryfewfeettofastenit.Ifanextensiontothewireprovidedisneeded,usethefollowingtabletodeterminetheminimumwiregaugeneeded:CHECKTOVERIFYCORRECTWIRINGTurnononezoneofthesprinklersystemthatisvisiblewhileyouareinreachoftherainsensor.Manuallydepressthemanualtestpinatthetopoftherainsensoruntilyouheartheswitch“click”off.Thesprinklerzoneshouldstopinstantly.Ifitdoesnot,checkwiringforcorrectinstallation.Note:Themanualactivationcycleofsomecontrollersbypassesthesensorinputs.IftheRainSensorisconnectedtothesensorterminals,youwillneedtorunanautomatic/timedwateringprogramforthesetypesofcontrollers.MountingtheRainSensorStandardFlatMounting
Mountthesensoronasurfacethatisunobstructedtorainfall.Butawayfromthepathofthesprinklerwaterspray.GutterMounting Allowstherainsensortobemounteddirectlytothesideofthegutter.Positiontheguttermountontheedgeofthegutterandtwistthethumbscrewtosecureitinplace.Hintsformounting:a. When looking for a suitable location such as the side of a building or post, the closer the Rain Sensor is to the controller the better. i. For the wired models, This will cause the wire run to be shorter, which minimizes the possibility of wire breaks ii. For the wireless model, the signal transmission will be better avoiding interference to the wireless signal.  b.  Mount in the highest possible position where rain can fall directly upon the rain sensor. c.  The rain sensor mounting location will affect the reset rate (amount of time it takes the rain sensor to dry out sufficiently for the sprinkler system to reactivate). For example, mounting the rain sensor on a very sunny, southeastern end of a building may cause the rain sensor to dry out sooner than desired. Similarly, mounting on the northern end of a building with constant shade may keep the rain sensor from drying out at all. Some experimentation with the “vent adjustment tab” will usually yield satisfactory results.
 ADJUSTMENTSANDOPERATIONWhentheRainSensoractivatesduetosufficientrainfall(afterrainfallquantitiesof1/8”thru½”ormore),thesprinklersystemwillbecomeinactiveuntilthemoisture‐absorbentdiscsinsidetheRainSensorhavedriedout.Toadjustittothedesiredquantityofrainfall,rotatethecapontherainsensorhousingtoadjusttherangedesired(SeeFigure3).Figure3Thetimethatittakestherainsensortoresetfornormalsprinkleroperationaftertherainhasstoppedisdeterminedbyweatherconditions(wind,sunlight,humidity,etc.).Theseconditionswilldeterminehowfastthehygroscopicdiscswilldryout,thesameconditionsyoursoilexperiences.Notethatthereisanadjustmentcapabilityontherainsensorthatwillslowdowntheresetrate.Byturningthe“VentAdjustmentTab”(SeeFigure4)tocompletelyorpartiallycovertheventilationholes,thehygroscopicdiscswilldrymoreslowly.Thisadjustmentcancompensateforan“overlysunny”installationlocationorpeculiarsoilconditions.Experimentingwiththeventringwillbestdeterminetheidealventsetting.Figure4BypassingtheRainSensorTheRainSensorcanbetemporarilybypassedordeactivatedusinganyoneofthefollowingmethods:•Usethecontroller’ssensorbypassswitch(ifequipped).•TemporarilydisconnecttheRainSensorfromthecontroller’swiring.
Note:Alwaysdisconnectpowertothecontrollerbeforeperforminganywiringtasks.AdditionalFeaturesofthe3208‐WRFS(WirelessRainFreezeSensor)‐ TheProEXControllercomesfromfactoryasdefault,withwiredrainsensorterminalenabled.OnceawirelessrainsensorhasbeenpairedwiththeProEXController,theterminalsforawiredrainsensorbecomesdisabled.‐ TheProEXControllerstoresthetemperatureanddateofthelastdaysuspendedwatering,madebyeitheraraineventorbythefreezesensor(whenambienttempwasbelowfreezingpoint).Todisplaythisinformation,putthecontrollerdialontheREMOTE/PINlocation.PresstheUPbutton,untilitdisplaystheSENSORinformationscreen.Thisscreenshowstheuserthebattery%remainingoftheirwirelessrainsensor,andthetemperatureofthelasttimetherainsensorwastriggered.Note:TheusercanalwayschangethetemperatureunitofmeasurementtoCelsiusdegreebypressingtheBACKandNEXTbuttonsSIMULTANEOUSLYonthisscreen.Togotothenextsensorfeature,presstheNEXTButtonanthescreenwilldisplayaDATE.Whichshowsthelastdaytherainsensorwastriggered.Thelastscreenonthissensorsection,showstheword“Wired”flashing.
ThissettingisusedtodeactivatethewirelessrainsensorandenablingtherainsensorterminalsoftheProEXcontroller.Inordertodothisselection,presstheBACKandNEXTbuttonsSIMULTANEOUSLYuntilthewordWIREDhasstoppedplashing.
SPECIFICATIONSSpecificationsMounting:2in1BracketforgutterbracketforstandardflatandgutterinstallationSensorType:Industry‐standardhygroscopicdiscstackwithadjustablerainfallsensitivityRating:3amp,24VAC,NC(NormallyClosecontacts)OperatingTemperatureRange:14°Fto149°F(‐10°Cto65°C)Hardware:StainlesssteelHousing:UV‐resistantengineeredpolymerFreezeSetPoint:37°Ffor3208‐WRFS(WirelessRainFreezeSensor)and3208‐HRFS(RainFreezeSensor)AdditionalSpecsforWirelessVersion:Rain/FreezeWirelessRange:Upto400feetor120meters(LineofSight)*AverageBatteryLife:isdesignedtooperateuptotenyears10Years(undernormalconditions)AdditionalSpecsforWiredVersions:ControlWire:25'outdoor‐rated,2‐wirecable,ULapprovedTROUBLESHOOTINGFollowthesesimplechecksbeforereplacingyourrainsensor:Systemwillnotcomeonatall:A.Checktoseethattherainsensordiscsaredryandswitch“clicks”onandofffreelybypressingthetopofthespindle.B.Lookforbreaksinthewireleadingtotherainsensorandcheckallwirejunctions.C.Iftherainsensorisdryandthewireleadingtoitisgood,checktherainsensorswitchbynickingtheinsulationofthetwo“outer”wiresneartheunittoexposecopper.Turnonesprinklerzoneon,andapplya“jumperwire”acrossthetwoexposedwires.Ifthesprinklernowcomeson,theswitchisbad.Wrapallnickedwireswithelectricaltape.D.Therainsensoriswiredtofunctionwithmostcontrollers(normallyclosed).Ifyouareunabletomakethesensorworkwiththesuggestionaboveyoumayhaveauniquecontroller(normallyopen).Systemwillnotshutoffevenafterheavyrainfall:A.Checkwiringforcorrectinstallation(See“AdjustmentsandOperation”section).B.Checksensitivitysettingonrainsensor,andmovethecaptoamoresensitivesetting.Therainsensorisanaccurateraingaugeandcanbeverifiedbysettingupa“tube”typeraingaugeinthesamevicinityandmakingperiodicreadings.C.Checkforobstructionstorainfallsuchasoverhangs,treesorwalls.WARRANTYK‐RainManufacturingwarrantsthatitsproductswillbefreefrommaterialsandworkmanshipdefectsforaperiodof2years.Withproofofpurchaseprovided,K‐Rainwillreplace,freeofcharge,thedefectivepartorpartsfoundtobedefectiveundernormaluseandserviceforthewarrantyperiod.Priortoreplacement,K‐Rainreservestherighttoinspectandauthorizethedefectivepartorparts;alldefectivesmustbeauthorizedinwritingbyK‐Rain.Liabilityunderthiswarrantyislimitedsolelytothereplacementorrepairofdefectiveparts.Thiswarrantyisgivenexpresslyandinplaceofallotherexpressedorimpliedwarrantiesincludingbutnotlimitedtowarrantiesregardingfitnessforuseofmerchantability.Noagentorrepresentativehasauthoritytowaiveoralterthiswarranty.
FCCNoticeSensorFCCID:2AHQM‐3208WRFSThisdevicecomplieswithFCCrulesPart15.Operationissubjecttothefollowingtwoconditions:1.Thisdevicemaynotcauseharmfulinterferenceand2.Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforclassBdigitaldevices,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyandifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentonandoff,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:•Reorientorrelocatethereceivingantenna•Increasetheseparationbetweentheequipmentandthereceiver•Connecttheequipmenttoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected•Consultthedealeroranexperiencedradio/TVtechnicianforhelpTheuseriscautionedthatchangesandmodificationsmadetotheequipmentwithouttheapprovalofthemanufacturercouldvoidtheuser’sauthoritytooperatethisequipment.Thedistancebetweenuserandproductsshouldbenolessthan20cm
FCCDeclarationofConformityThisequipmenthasbeentestedandfoundtocomplywiththelimitsforclassBdigitaldevices,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyandifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,pleaserefertoyouuser'smanualforinstructionsoncorrectingtheproblem.Theundersigned,herebydeclarethattheequipmentspecifiedaboveconformstotheaboverequirements.NOTES

Navigation menu