KAPSCH TRAFFICCOM CANADA 801531 RFM-S Transmitter User Manual TTS Reader User Guide for testing RFM S

KAPSCH TRAFFICCOM CANADA INC. RFM-S Transmitter TTS Reader User Guide for testing RFM S

Field Testing Guide

    Page 1 of  2 ©©  MMAARRKK  IIVV  IINNDDUUSSTTRRIIEESS  CCoorrpp..  EEXXCCEEPPTT  AASS  MMAAYY  BBEE  OOTTHHEERRWWIISSEE  PPRROOVVIIDDEEDD  BBYY  CCOONNTTRRAACCTT,,  TTHHEESSEE  DDRRAAWWIINNGGSS  AANNDD  SSPPEECCIIFFIICCAATTIIOONNSS  CCOONNTTAAIINN  PPRROOPPRRIIEETTAARRYY  IINNFFOORRMMAATTIIOONN  AANNDD  AARREE  TTHHEE  PPRROOPPEERRTTYY  OOFF  MMAARRKK  IIVV  IINNDDUUSSTTRRIIEESS  LLTTDD..  AANNDD  AARREE  IISSSSUUEEDD  IINN  SSTTRRIICCTT  CCOONNFFIIDDEENNCCEE  AANNDD  SSHHAALLLL  NNOOTT  BBEE  TTRRAANNSSMMIITTTTEEDD  OORR  RREEPPRROODDUUCCEEDD  OORR  CCOOPPIIEEDD  OORR  UUSSEEDD  AASS  TTHHEE  BBAASSIISS  FFOORR  MMAANNUUFFAACCTTUURREE  OORR  SSAALLEE  OOFF  AAPPPPAARRAATTUUSS  WWIITTHHOOUUTT  PPRRIIOORR  WWRRIITTTTEENN  PPEERRMMIISSSSIIOONN..  Mark IV Industries Corp. RFM-S Transmitter Field Testing Guide  With Warning Statements Confidential   A.  Set Up TTS Reader:  Serial Comms:  RS-232  19200 baud No Parity etc. standard stuff.  The cable (null modem) runs out the top of the reader; connect to any DB-9 port on your host computer. Use a Straight through cable (male-female) if you need to extend the length.  B.    Set up TTS with RFM-S Transmitter:  The RFM-S Transmitter must be inserted in Slot #1 (the left most) of the RF Rack.  C.   List of Commands: (power on default)  IAGTEST Help Menu - NOT FOR PRODUCTION USE PT <2-28 hex #>    - Program Tag, MASK data must match RT                   - Read Tag IP                 - Initialize Tag (FP ff's) FP <2-28 hex #>    - Factory Program Tag, MSb must be 1 LP <2-28 hex #>    - Lock Program Tag, MSb must be 1 TP    <6 hex #>    - Trim Program Tag, MSB (FF), IDLE(XX), ACTIVE(XX)                          (with VERIFY ON, FP is performed with TP data) TL                   - Lock Trim Values in Tag IC     [<#>]        - Iteration Count, # of triggers per RT/PT PW     [<#>] us    - Pulse Width, either 20, 33 or 40 us  REPEAT [<#>]       - Repeat Count, repeat PT/RT/FP/TP # times - ESC to stop DELAY  [<#>|OFF]   - Repeat Delay, repeat cycle delay, OFF for no screen updates DETAIL [ON |OFF]   - Repeat Detail ON/OFF, show full data during repeat cycles INC    [ON |OFF]   - Repeat Increment ON/OFF, increment last 4 bytes during PT STAT   [ON |OFF]   - Repeat Statistics ON/OFF, displays on last cycle VERIFY [ON |OFF]   - IP/FP/LP/TP Verify ON/OFF (PT always verifies) PD     [<#>]       - Program Delay. TXDATA delay between TRIGGER and                              IP/FP/LP/TP data (NOT header): # us = ~ PD x 2.4 + 60                                        ex. 250 (default) = ~ 660 us (nominal) CONFIG             - Return Configuration Summary  The above list can be obtained by typing ?<enter>.
    Page 2 of  2 ©©  MMAARRKK  IIVV  IINNDDUUSSTTRRIIEESS  CCoorrpp..  EEXXCCEEPPTT  AASS  MMAAYY  BBEE  OOTTHHEERRWWIISSEE  PPRROOVVIIDDEEDD  BBYY  CCOONNTTRRAACCTT,,  TTHHEESSEE  DDRRAAWWIINNGGSS  AANNDD  SSPPEECCIIFFIICCAATTIIOONNSS  CCOONNTTAAIINN  PPRROOPPRRIIEETTAARRYY  IINNFFOORRMMAATTIIOONN  AANNDD  AARREE  TTHHEE  PPRROOPPEERRTTYY  OOFF  MMAARRKK  IIVV  IINNDDUUSSTTRRIIEESS  LLTTDD..  AANNDD  AARREE  IISSSSUUEEDD  IINN  SSTTRRIICCTT  CCOONNFFIIDDEENNCCEE  AANNDD  SSHHAALLLL  NNOOTT  BBEE  TTRRAANNSSMMIITTTTEEDD  OORR  RREEPPRROODDUUCCEEDD  OORR  CCOOPPIIEEDD  OORR  UUSSEEDD  AASS  TTHHEE  BBAASSIISS  FFOORR  MMAANNUUFFAACCTTUURREE  OORR  SSAALLEE  OOFF  AAPPPPAARRAATTUUSS  WWIITTHHOOUUTT  PPRRIIOORR  WWRRIITTTTEENN  PPEERRMMIISSSSIIOONN..   D.    Procedure to test and activate RFM-S:  In idle mode the reader generates NO RF. (RFM-S transmitter light off). To turn on the RFM-S transmitter do the following: 1) Set the iteration count to a large number (   IC 1000   ) 2) Issue a read transponder command  (  RT   )  The iteration count is the number of 20 microsecond trigger pulses the reader will issue for every RT command.   for ic=1000 the reader will transmit for about 6-7 seconds. for ic=2000 the time is around 13 seconds. Max is 32767  Ignore all other commands.  E.   Example:  ic 1000   //user input IC=1000   //reader confirms               rt   //user input READ ERROR   //after 1000 trigger pulses (about 6 secs later) reader       //responds with "READ ERROR" since (we assume) no transponder     //has been read.  (The iteration count is persistent. It remains the same unless changed or the reader is reset).   F.    Warning Statement:  This device complies with Part 90 of the FCC Rules.   Modifications not expressly approved by the manufacturer may invalidate the user’s authority to operate the equipment

Navigation menu